- LibreNMS Discovery
- Version info:
- Commit SHA: d8fcdc9ae3cf7a5cdafca865c9ada7551f85a03f
- DB Schema: 185
- PHP: 7.0.17
- MySQL: 5.5.52-MariaDB
- RRDTool: 1.4.8
- SNMP: NET-SNMP 5.7.2
- DEBUG!
- SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1]
- DB Schema already up to date.
- SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'nb-vmmsa.nbisd.edu' ORDER BY device_id DESC]
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '104']
- nb-vmmsa.nbisd.edu 104 hpe-msa SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.22','0.43','0.32','104',NOW())]
- SNMP Check response code: 0
- Modules status: Global+ OS Device
- #### Load disco module os ####
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- HP StorageWorks P2000 G3 iSCSI
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.*.51
- | HP StorageWorks P2000 G3 iSCSI | .1.3.6.1.4.1.11.2.51 |
- >> Runtime for discovery module 'os': 0.0890 seconds with 912 bytes
- #### Unload disco module os ####
- Modules status: Global+ OS Device
- #### Load disco module ports ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifDescr]
- ifDescr.1 = lo
- ifDescr.2 = eth0
- ifDescr.3 = sit0
- ifDescr.4 = sl0
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifName]
- ifName.1 = lo
- ifName.2 = eth0
- ifName.3 = sit0
- ifName.4 = sl0
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifAlias]
- ifAlias.1 =
- ifAlias.2 =
- ifAlias.3 =
- ifAlias.4 =
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifType]
- ifType.1 = softwareLoopback
- ifType.2 = ethernetCsmacd
- ifType.3 = tunnel
- ifType.4 = slip
- Array
- (
- [1] => Array
- (
- [ifDescr] => lo
- [ifName] => lo
- [ifAlias] =>
- [ifType] => softwareLoopback
- )
- [2] => Array
- (
- [ifDescr] => eth0
- [ifName] => eth0
- [ifAlias] =>
- [ifType] => ethernetCsmacd
- )
- [3] => Array
- (
- [ifDescr] => sit0
- [ifName] => sit0
- [ifAlias] =>
- [ifType] => tunnel
- )
- [4] => Array
- (
- [ifDescr] => sl0
- [ifName] => sl0
- [ifAlias] =>
- [ifType] => slip
- )
- )
- SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '104' ORDER BY port_id]
- ...ignored : /^sl[0-9]/ : sl0X
- >> Runtime for discovery module 'ports': 0.0710 seconds with 2080 bytes
- #### Unload disco module ports ####
- Modules status: Global+ OS Device
- #### Load disco module ports-stack ####
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '104']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifStackStatus]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.3420 seconds with 640 bytes
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalEntry]
- entPhysicalEntry = No Such Object available on this agent at this OID
- entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entAliasMappingIdentifier]
- entAliasMappingIdentifier = No Such Object available on this agent at this OID
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '104']
- >> Runtime for discovery module 'entity-physical': 4.3030 seconds with 2928 bytes
- #### Unload disco module entity-physical ####
- Modules status: Global+ OS Device
- #### Load disco module processors ####
- hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrDevice]
- hrDevice = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrProcessorLoad]
- hrProcessorLoad = No Such Object available on this agent at this OID
- SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '104' AND `processor_type` != 'ucd-old']
- SQL[SELECT * FROM `processors` WHERE `device_id` = '104']
- >> Runtime for discovery module 'processors': 0.0430 seconds with 33824 bytes
- #### Unload disco module processors ####
- Modules status: Global+ OS Device
- #### Load disco module mempools ####
- SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '104' AND `mempool_type` = 'cemp']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = No Such Object available on this agent at this OID
- SQL[SELECT * FROM `mempools` WHERE `device_id` = '104']
- >> Runtime for discovery module 'mempools': 0.0760 seconds with 22320 bytes
- #### Unload disco module mempools ####
- Modules status: Global+ OS Device
- #### Load disco module cisco-vrf-lite ####
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '104' ]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1544 bytes
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-pw ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cef ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-sla ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-otv ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module ipv4-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntIfIndex]
- ipAdEntIfIndex.* 1
- ipAdEntIfIndex.* 2
- ipAdEntIfIndex.* 4
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '1']
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '1']
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
- SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.0/8']
- sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '7439' ]
- SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '7439']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.172.16.239.230]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '2']
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '2']
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.232.0/21']
- SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.16.232.0/21']
- sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.232.0/21']
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.16.239.230' AND `ipv4_prefixlen` = '21' AND `port_id` = '7440' ]
- SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.16.239.230' AND `ipv4_prefixlen` = '21' AND `port_id` = '7440']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.172.22.255.254]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '4']
- !SQL[SELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '104' AND A.port_id = I.port_id]
- >> Runtime for discovery module 'ipv4-addresses': 0.1920 seconds with 16584 bytes
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS Device
- #### Load disco module ipv6-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
- ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipv6AddrPfxLength]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[SELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '104' AND A.port_id = I.port_id]
- >> Runtime for discovery module 'ipv6-addresses': 0.0450 seconds with 6608 bytes
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS Device Module [ route ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalDescr]
- entPhysicalDescr = No Such Object available on this agent at this OID
- entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalName]
- entPhysicalName = No Such Object available on this agent at this OID
- entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorType]
- entPhySensorType = No Such Object available on this agent at this OID
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorScale]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorPrecision]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorValue]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '104' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi']
- Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 0.1430 seconds with 7760 bytes
- #### Unload disco module sensors ####
- Modules status: Global+ OS Device
- #### Load disco module storage ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry]
- eqliscsiVolumeEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dfEntry]
- dfEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dskTable]
- dskTable = No Such Object available on this agent at this OID
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '104' AND `storage_type` != 'dsk']
- SQL[SELECT * FROM `storage` WHERE `device_id` = '104']
- >> Runtime for discovery module 'storage': 0.1060 seconds with 3400 bytes
- #### Unload disco module storage ####
- Modules status: Global+ OS Device
- #### Load disco module hr-device ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrDeviceEntry]
- hrDeviceEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrProcessorEntry]
- hrProcessorEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '104']
- >> Runtime for discovery module 'hr-device': 0.0390 seconds with 792 bytes
- #### Unload disco module hr-device ####
- Modules status: Global+ OS Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: OSPF Discovery: disabled
- SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '104']
- >> Runtime for discovery module 'discovery-protocols': 0.0010 seconds with 4208 bytes
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS Device
- #### Load disco module arp-table ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
- ipNetToPhysicalPhysAddress.2.ipv4."*" = b8:af:67:63:e5:23
- ipNetToPhysicalPhysAddress.2.ipv4."*" = 0:0:0:0:0:0
- ipNetToPhysicalPhysAddress.2.ipv4."*" = 0:c0:ff:12:ae:47
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipNetToMediaPhysAddress]
- ipNetToMediaPhysAddress.*.1 = b8:af:67:63:e5:23
- ipNetToMediaPhysAddress.*.43 = 0:50:56:be:40:d2
- ipNetToMediaPhysAddress.*.231 = 0:c0:ff:12:ae:47
- SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='104' AND M.context_name='']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '2']
- >> Runtime for discovery module 'arp-table': 0.0400 seconds with 18536 bytes
- #### Unload disco module arp-table ####
- Modules status: Global- OS Device Module [ discovery-arp ] disabled globally.
- Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module bgp-peers ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 .1.3.6.1.2.1.15.2]
- No Such Object available on this agent at this OID
- No BGP on hostPeers :
- SQL[SELECT * FROM bgpPeers WHERE device_id = '104' AND (context_name = '' OR context_name IS NULL)]
- >> Runtime for discovery module 'bgp-peers': 0.0180 seconds with 2672 bytes
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS Device
- #### Load disco module vlans ####
- SQL[SELECT * FROM `vlans` WHERE `device_id` = '104']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1dBasePortIfIndex]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1qVlanVersionNumber.0]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.0440 seconds with 4320 bytes
- #### Unload disco module vlans ####
- Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally.
- Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally.
- Modules status: Global- OS Device Module [ toner ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module ucd-diskio ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 diskIOEntry]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '104']
- >> Runtime for discovery module 'ucd-diskio': 0.0170 seconds with 736 bytes
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS Device Module [ applications ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
- #### Unload disco module services ####
- Modules status: Global+ OS Device
- #### Load disco module stp ####
- SQL[SELECT * FROM `stp` WHERE `device_id` = '104']
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0130 seconds with 3648 bytes
- #### Unload disco module stp ####
- Modules status: Global+ OS Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 8.6060 seconds with 144 bytes
- #### Unload disco module ntp ####
- Modules status: Global- OS Device Module [ loadbalancers ] disabled globally.
- Modules status: Global- OS Device Module [ mef ] disabled globally.
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '104' AND `attrib_type` = 'poll_mib' ]
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.038' WHERE `device_id` = '104']
- Discovered in 6.038 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','nb-vmmsa.nbisd.edu','1492654470.829','6.073','1','nms.nbisd.edu\n')]
- /opt/librenms/discovery.php nb-vmmsa.nbisd.edu 2017-04-19 21:14:36 - 1 devices discovered in 6.073 secs
- SNMP: Get[8/0.16s] Walk [30/4.91s]
- MySQL: Cell[16/0.01s] Row[5/0.00s] Rows[37/0.01s] Column[1/0.00s] Update[5/0.12s] Insert[2/0.02s] Delete[0/0.00s]
- .