LibreNMS Discovery Version info: Commit SHA: d8fcdc9ae3cf7a5cdafca865c9ada7551f85a03f DB Schema: 185 PHP: 7.0.17 MySQL: 5.5.52-MariaDB RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2 DEBUG! SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1] DB Schema already up to date. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'nb-vmmsa.nbisd.edu' ORDER BY device_id DESC] SQL[SELECT * FROM devices_attribs WHERE `device_id` = '104'] nb-vmmsa.nbisd.edu 104 hpe-msa SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.22','0.43','0.32','104',NOW())] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module os #### SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0] HP StorageWorks P2000 G3 iSCSI SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0] .*.*.51 | HP StorageWorks P2000 G3 iSCSI | .1.3.6.1.4.1.11.2.51 | >> Runtime for discovery module 'os': 0.0890 seconds with 912 bytes #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifDescr] ifDescr.1 = lo ifDescr.2 = eth0 ifDescr.3 = sit0 ifDescr.4 = sl0 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifName] ifName.1 = lo ifName.2 = eth0 ifName.3 = sit0 ifName.4 = sl0 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifAlias] ifAlias.1 = ifAlias.2 = ifAlias.3 = ifAlias.4 = SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifType] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifType.3 = tunnel ifType.4 = slip Array ( [1] => Array ( [ifDescr] => lo [ifName] => lo [ifAlias] => [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => eth0 [ifName] => eth0 [ifAlias] => [ifType] => ethernetCsmacd ) [3] => Array ( [ifDescr] => sit0 [ifName] => sit0 [ifAlias] => [ifType] => tunnel ) [4] => Array ( [ifDescr] => sl0 [ifName] => sl0 [ifAlias] => [ifType] => slip ) ) SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1'] SQL[SELECT * FROM `ports` WHERE `device_id` = '104' ORDER BY port_id] ...ignored : /^sl[0-9]/ : sl0X >> Runtime for discovery module 'ports': 0.0710 seconds with 2080 bytes #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '104'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ifStackStatus] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.3420 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalEntry] entPhysicalEntry = No Such Object available on this agent at this OID entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entAliasMappingIdentifier] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '104'] >> Runtime for discovery module 'entity-physical': 4.3030 seconds with 2928 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS Device #### Load disco module processors #### hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrDevice] hrDevice = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrProcessorLoad] hrProcessorLoad = No Such Object available on this agent at this OID SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '104' AND `processor_type` != 'ucd-old'] SQL[SELECT * FROM `processors` WHERE `device_id` = '104'] >> Runtime for discovery module 'processors': 0.0430 seconds with 33824 bytes #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '104' AND `mempool_type` = 'cemp'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal] hpLocalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal] hpGlobalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SQL[SELECT * FROM `mempools` WHERE `device_id` = '104'] >> Runtime for discovery module 'mempools': 0.0760 seconds with 22320 bytes #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '104' ] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1544 bytes #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntIfIndex] ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 2 ipAdEntIfIndex.* 4 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '1'] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '1'] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'] SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.0/8'] sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '7439' ] SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '7439'] .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.172.16.239.230] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '2'] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '2'] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.232.0/21'] SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.16.232.0/21'] sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.232.0/21'] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.16.239.230' AND `ipv4_prefixlen` = '21' AND `port_id` = '7440' ] SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.16.239.230' AND `ipv4_prefixlen` = '21' AND `port_id` = '7440'] .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAdEntNetMask.172.22.255.254] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '104' AND `ifIndex` = '4'] !SQL[SELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '104' AND A.port_id = I.port_id] >> Runtime for discovery module 'ipv4-addresses': 0.1920 seconds with 16584 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipAddressIfIndex.ipv6] ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipv6AddrPfxLength] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[SELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '104' AND A.port_id = I.port_id] >> Runtime for discovery module 'ipv6-addresses': 0.0450 seconds with 6608 bytes #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalDescr] entPhysicalDescr = No Such Object available on this agent at this OID entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalName] entPhysicalName = No Such Object available on this agent at this OID entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorType] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorScale] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorPrecision] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhySensorValue] entPhySensorValue = No Such Object available on this agent at this OID SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '104' AND `attrib_type` = 'ipmi_hostname' ] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'ipmi'] Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '104' AND S.poller_type = 'snmp'] >> Runtime for discovery module 'sensors': 0.1430 seconds with 7760 bytes #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dfEntry] dfEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dskTable] dskTable = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '104' AND `storage_type` != 'dsk'] SQL[SELECT * FROM `storage` WHERE `device_id` = '104'] >> Runtime for discovery module 'storage': 0.1060 seconds with 3400 bytes #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrDeviceEntry] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hrProcessorEntry] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '104'] >> Runtime for discovery module 'hr-device': 0.0390 seconds with 792 bytes #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: OSPF Discovery: disabled SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '104'] >> Runtime for discovery module 'discovery-protocols': 0.0010 seconds with 4208 bytes #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipNetToPhysicalPhysAddress] ipNetToPhysicalPhysAddress.2.ipv4."*" = b8:af:67:63:e5:23 ipNetToPhysicalPhysAddress.2.ipv4."*" = 0:0:0:0:0:0 ipNetToPhysicalPhysAddress.2.ipv4."*" = 0:c0:ff:12:ae:47 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 ipNetToMediaPhysAddress] ipNetToMediaPhysAddress.*.1 = b8:af:67:63:e5:23 ipNetToMediaPhysAddress.*.43 = 0:50:56:be:40:d2 ipNetToMediaPhysAddress.*.231 = 0:c0:ff:12:ae:47 SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='104' AND M.context_name=''] SQL[SELECT * FROM `ports` WHERE `device_id` = '104' AND `ifIndex` = '2'] >> Runtime for discovery module 'arp-table': 0.0400 seconds with 18536 bytes #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 .1.3.6.1.2.1.15.2] No Such Object available on this agent at this OID No BGP on hostPeers : SQL[SELECT * FROM bgpPeers WHERE device_id = '104' AND (context_name = '' OR context_name IS NULL)] >> Runtime for discovery module 'bgp-peers': 0.0180 seconds with 2672 bytes #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = '104'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1dBasePortIfIndex] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1qVlanVersionNumber.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0440 seconds with 4320 bytes #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ toner ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 diskIOEntry] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '104'] >> Runtime for discovery module 'ucd-diskio': 0.0170 seconds with 736 bytes #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[SELECT * FROM `stp` WHERE `device_id` = '104'] SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 dot1dStpProtocolSpecification.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0130 seconds with 3648 bytes #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 8.6060 seconds with 144 bytes #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '104' AND `attrib_type` = 'poll_mib' ] SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.038' WHERE `device_id` = '104'] Discovered in 6.038 seconds SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','nb-vmmsa.nbisd.edu','1492654470.829','6.073','1','nms.nbisd.edu\n')] /opt/librenms/discovery.php nb-vmmsa.nbisd.edu 2017-04-19 21:14:36 - 1 devices discovered in 6.073 secs SNMP: Get[8/0.16s] Walk [30/4.91s] MySQL: Cell[16/0.01s] Row[5/0.00s] Rows[37/0.01s] Column[1/0.00s] Update[5/0.12s] Insert[2/0.02s] Delete[0/0.00s] .