From Bowl2much, 1 Year ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2.  
  3. SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 0.73ms]
  4.  
  5.  
  6. SQL[select count(*) as aggregate from `migrations` limit 1 [] 1.02ms]
  7.  
  8.  
  9. SQL[select version() [] 0.69ms]
  10.  
  11.  
  12. ===================================
  13. Version info:
  14. Commit SHA:
  15. Commit Date:
  16. DB Schema: 2022_07_19_081224_plugins_unique_index (244)
  17. PHP: 8.0.22
  18. Database: MariaDB 10.5.17-MariaDB-1:10.5.17+maria~ubu2004
  19. RRDTool: 1.7.2
  20. SNMP: 5.9.3
  21. ==================================DEBUG!
  22.  
  23. Updating os_def.cache  
  24.  
  25.  
  26. Warning: file_put_contents(/opt/librenms/cache/os_defs.cache): Failed to open stream: Permission denied in /opt/librenms/LibreNMS/Util/OS.php on line 111
  27.  
  28. SQL[SELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE '10.0.0.251' ORDER BY device_id DESC [] 1.36ms]
  29.  
  30.  
  31. SQL[select * from `devices` where `device_id` = ? limit 1 [23] 0.89ms]
  32.  
  33.  
  34. SQL[select * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [23] 0.88ms]
  35.  
  36.  
  37. 10.0.0.251 23 poweralert
  38. [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' '10.0.0.251'
  39.  
  40.  
  41. response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.594/0.607/0.627  
  42.  
  43. SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0']  
  44.  
  45. SNMPv2-MIB::sysObjectID.0 = SNMPv2-SMI::enterprises.8*
  46.  
  47.  
  48.  
  49.  
  50. Modules status: Global+  
  51.  
  52. OS  
  53.  
  54. Device  
  55.  
  56. #### Load disco module core ####
  57.  
  58. Attempting to initialize OS: poweralert  
  59.  
  60. OS initialized: LibreNMS\OS\Poweralert  
  61.  
  62. SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0']  
  63.  
  64. .*.*.0 = .*.4.1.8*
  65. .*.*.0 = Ubuntu 16.04.6 LTS Linux 4.4.31 flash: 3.4G ram: 506844kB processor: armv7l software: PowerAlert 15.5.5 (Build 1069)
  66. .*.*.0 = poweralert-0610365179147
  67.  
  68.  
  69.  
  70.  
  71. | Ubuntu 16.04.6 LTS Linux 4.4.31 flash: 3.4G ram: 506844kB processor: armv7l software: PowerAlert 15.5.5 (Build 1069) | .1.3.6.1.4.1.850.1.1.1 |
  72.  
  73.  
  74. OS: Tripp Lite PowerAlert (poweralert)
  75.  
  76.  
  77. Attempting to initialize OS: poweralert  
  78. OS initialized: LibreNMS\OS\Poweralert  
  79.  
  80. >> Runtime for discovery module 'core': 0.0660 seconds with 23360 bytes
  81.  
  82. >> SNMP: [1/0.04s] MySQL: [0/0.00s] RRD: [0/0.00s]  
  83. #### Unload disco module core ####
  84.  
  85.  
  86. Modules status: Global+  
  87.  
  88. OS  
  89. Device  
  90.  
  91. #### Load disco module os ####
  92.  
  93. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.100.1.1.6.0']
  94.  
  95. .*.4.1.8*.6.0 = No Such Object available on this agent at this OID  
  96.  
  97.  
  98.  
  99. Yaml location data:  
  100.  
  101. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0']
  102.  
  103.  
  104.  
  105.  
  106.  
  107. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'sysContact.0']
  108.  
  109.  
  110.  
  111.  
  112.  
  113. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.10.2.2.1.9.2' '.1.3.6.1.2.1.33.1.1.2.0' '.1.3.6.1.4.1.850.100.1.1.2.0' '.1.3.6.1.2.1.33.1.1.4.0' '.1.3.6.1.2.1.33.1.1.3.0']
  114.  
  115. .*.4.1.8*.1.9.2 = No Such Object available on this agent at this OID
  116. .*.*.1.2.0 = No Such Instance currently exists at this OID
  117. .*.4.1.8*.2.0 = No Such Object available on this agent at this OID
  118. .*.*.1.4.0 = "15.5.5 (Build 1069)"
  119. .*.*.1.3.0 = No Such Instance currently exists at this OID  
  120.  
  121.  
  122.  
  123. Yaml OS data: {".1.3.6.1.2.1.33.1.1.4.0":"15.5.5 (Build 1069)"}
  124.  
  125. SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.1.5.0']  
  126.  
  127. SNMPv2-SMI::mib-*.5.0 = No Such Instance currently exists at this OID
  128.  
  129.  
  130.  
  131.  
  132. Location:
  133.  
  134. Hardware:
  135.  
  136. OS Version: 15.5.5 (Build 1069)
  137.  
  138. OS Features:
  139.  
  140. Serial:
  141.  
  142.  
  143. >> Runtime for discovery module 'os': 0.2020 seconds with 152864 bytes
  144. >> SNMP: [5/0.19s] MySQL: [0/0.00s] RRD: [0/0.00s]  
  145. #### Unload disco module os ####
  146.  
  147. Modules status: Global+  
  148. OS  
  149.  
  150. Device  
  151.  
  152. #### Load disco module ports ####
  153.  
  154. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifDescr']
  155.  
  156. ifDescr.1 = lo
  157. ifDescr.2 = eth0  
  158.  
  159.  
  160.  
  161. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifName']
  162.  
  163. ifName = No Such Object available on this agent at this OID  
  164.  
  165.  
  166. Invalid snmp_walk() data = ifName = No Such Object available on this agent at this OID  
  167.  
  168. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifAlias']
  169.  
  170. ifAlias = No Such Object available on this agent at this OID  
  171.  
  172.  
  173.  
  174. Invalid snmp_walk() data = ifAlias = No Such Object available on this agent at this OID  
  175.  
  176. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifType']
  177.  
  178. ifType.1 = softwareLoopback
  179. ifType.2 = ethernetCsmacd  
  180.  
  181.  
  182.  
  183. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifOperStatus']
  184.  
  185. ifOperStatus.1 = up
  186. ifOperStatus.2 = up  
  187.  
  188.  
  189.  
  190. array (
  191.   1 =>
  192.   array (
  193.     'ifDescr' => 'lo',
  194.     'ifType' => 'softwareLoopback',
  195.     'ifOperStatus' => 'up',
  196.   ),
  197.   2 =>
  198.   array (
  199.     'ifDescr' => 'eth0',
  200.     'ifType' => 'ethernetCsmacd',
  201.     'ifOperStatus' => 'up',
  202.   ),
  203. )  
  204.  
  205. SQL[SELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [23] 1.4ms]
  206.  
  207.  
  208.  
  209. Warning: Undefined array key "ifAlias" in /opt/librenms/includes/discovery/ports.inc.php on line 84
  210.  
  211. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 629
  212.  
  213.  
  214. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 703
  215.  
  216.  Using ifDescr as ifAlias  
  217.  
  218. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 712
  219.  
  220.  Using ifDescr as ifName  
  221.  
  222. SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["lo","softwareLoopback","up",1,"lo","lo",515] 0.69ms]
  223.  
  224.  
  225. .
  226. Warning: Undefined array key "ifAlias" in /opt/librenms/includes/discovery/ports.inc.php on line 84
  227.  
  228. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 629
  229.  
  230. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 703
  231.  
  232.  Using ifDescr as ifAlias  
  233.  
  234. Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 712
  235.  
  236.  Using ifDescr as ifName  
  237.  
  238. SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["eth0","ethernetCsmacd","up",2,"eth0","eth0",516] 0.62ms]
  239.  
  240.  
  241. .
  242.  
  243.  
  244. >> Runtime for discovery module 'ports': 0.1840 seconds with 4376 bytes
  245. >> SNMP: [5/0.18s] MySQL: [3/0.03s] RRD: [0/0.00s]  
  246.  
  247. #### Unload disco module ports ####
  248.  
  249. Modules status: Global+  
  250.  
  251. OS  
  252.  
  253. Device  
  254.  
  255. #### Load disco module ports-stack ####
  256.  
  257. SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '23' [] 0.74ms]
  258.  
  259.  
  260. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifStackStatus']
  261.  
  262. ifStackStatus = No Such Object available on this agent at this OID  
  263.  
  264.  
  265.  
  266.  
  267.  
  268. >> Runtime for discovery module 'ports-stack': 0.0540 seconds with 32 bytes
  269. >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  270.  
  271. #### Unload disco module ports-stack ####
  272.  
  273.  
  274. Modules status: Global+  
  275. OS  
  276. Device  
  277.  
  278.  
  279. #### Load disco module entity-physical ####
  280.  
  281.  
  282. Caching OIDs: entPhysicalEntry
  283. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'entPhysicalEntry']
  284.  
  285. entPhysicalEntry = No Such Object available on this agent at this OID  
  286.  
  287. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  288. Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 65 in (none)  
  289.  
  290. Invalid snmp_walk() data = entPhysicalEntry = No Such Object available on this agent at this OID  
  291.  
  292.  
  293. SQL[SELECT * FROM `entPhysical` WHERE `device_id` = ? [23] 1ms]
  294.  
  295.  
  296.  
  297. >> Runtime for discovery module 'entity-physical': 0.0380 seconds with 5840 bytes
  298.  
  299. >> SNMP: [1/0.04s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  300. #### Unload disco module entity-physical ####
  301.  
  302.  
  303. Modules status: Global-  
  304. OS  
  305.  
  306. Device  
  307. Module [ entity-state ] disabled globally.
  308.  
  309. Modules status: Global-  
  310.  
  311. OS  
  312. Device  
  313. Module [ isis ] disabled globally.
  314.  
  315.  
  316. Modules status: Global+  
  317.  
  318. OS  
  319. Device  
  320.  
  321. #### Load disco module processors ####
  322.  
  323. No YAML Discovery data.  
  324. Host Resources:
  325. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrProcessorLoad']
  326.  
  327. hrProcessorLoad = No Such Object available on this agent at this OID  
  328.  
  329.  
  330.  
  331. Invalid snmp_walk() data = hrProcessorLoad = No Such Object available on this agent at this OID  
  332. UCD Resources:
  333. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0']
  334.  
  335. No Such Object available on this agent at this OID  
  336.  
  337.  
  338.  
  339. SQL[SELECT * FROM `processors` WHERE `device_id`=? [23] 1.03ms]
  340.  
  341.  
  342. SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 0.76ms]
  343.  
  344.  
  345.  
  346.  
  347.  
  348. >> Runtime for discovery module 'processors': 0.1050 seconds with 24144 bytes
  349. >> SNMP: [2/0.10s] MySQL: [2/0.02s] RRD: [0/0.00s]  
  350.  
  351. #### Unload disco module processors ####
  352.  
  353. Modules status: Global+  
  354.  
  355. OS  
  356.  
  357. Device  
  358.  
  359. #### Load disco module mempools ####
  360.  
  361. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrStorageTable']
  362.  
  363. hrStorageTable = No Such Object available on this agent at this OID  
  364.  
  365.  
  366.  
  367. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrMemorySize.0']
  368.  
  369. No Such Object available on this agent at this OID  
  370.  
  371.  
  372.  
  373. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0']
  374.  
  375. memTotalSwap.0 = No Such Object available on this agent at this OID
  376. memAvailSwap.0 = No Such Object available on this agent at this OID
  377. memTotalReal.0 = No Such Object available on this agent at this OID
  378. memAvailReal.0 = No Such Object available on this agent at this OID
  379. memBuffer.0 = No Such Object available on this agent at this OID
  380. memCached.0 = No Such Object available on this agent at this OID
  381. memSysAvail.0 = No Such Object available on this agent at this OID  
  382.  
  383.  
  384.  
  385. SQL[select * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [23] 0.95ms]
  386.  
  387.  
  388.  
  389.  
  390.  
  391. >> Runtime for discovery module 'mempools': 0.1090 seconds with 32480 bytes
  392.  
  393. >> SNMP: [2/0.05s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  394. #### Unload disco module mempools ####
  395.  
  396.  
  397. Modules status: Global+  
  398.  
  399. OS  
  400. Device  
  401.  
  402. #### Load disco module cisco-vrf-lite ####
  403.  
  404.  
  405. Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/cisco-vrf-lite.inc.php on line 24
  406.  
  407. SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = ?  [23] 0.67ms]
  408.  
  409.  
  410.  
  411. >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 80 bytes
  412.  
  413. >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  414.  
  415. #### Unload disco module cisco-vrf-lite ####
  416.  
  417.  
  418. Modules status: Global-  
  419. OS  
  420. Device  
  421. Module [ cisco-mac-accounting ] disabled globally.
  422.  
  423.  
  424. Modules status: Global-  
  425.  
  426. OS  
  427. Device  
  428. Module [ cisco-pw ] disabled globally.
  429.  
  430. Modules status: Global-  
  431.  
  432. OS  
  433. Device  
  434. Module [ vrf ] disabled globally.
  435.  
  436. Modules status: Global-  
  437.  
  438. OS  
  439. Device  
  440. Module [ cisco-cef ] disabled globally.
  441.  
  442.  
  443. Modules status: Global-  
  444. OS  
  445.  
  446. Device  
  447. Module [ slas ] disabled globally.
  448.  
  449.  
  450. Modules status: Global-  
  451. OS  
  452. Device  
  453. Module [ cisco-cbqos ] disabled globally.
  454.  
  455.  
  456. Modules status: Global-  
  457. OS  
  458.  
  459. Device  
  460. Module [ cisco-otv ] disabled globally.
  461.  
  462.  
  463. Modules status: Global-  
  464. OS  
  465. Device  
  466.  
  467. Module [ cisco-qfp ] disabled globally.
  468.  
  469.  
  470. Modules status: Global+  
  471. OS  
  472. Device  
  473.  
  474. #### Load disco module ipv4-addresses ####
  475.  
  476. SQL[select * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [23] 0.84ms]
  477.  
  478.  
  479. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntIfIndex']
  480.  
  481. ipAdEntIfIndex.* 2
  482. ipAdEntIfIndex.* 1  
  483.  
  484.  
  485.  
  486. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.0.0.251']
  487.  
  488. *  
  489.  
  490.  
  491.  
  492. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [23,"2"] 1.19ms]
  493.  
  494.  
  495. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,"2"] 0.82ms]
  496.  
  497.  
  498. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.0.0.0\/24"] 0.86ms]
  499.  
  500.  
  501. SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? ["","10.0.0.0\/24"] 0.75ms]
  502.  
  503.  
  504. s
  505. SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.0.0.0\/24"] 0.72ms]
  506.  
  507.  
  508. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ?  ["10.0.0.251",24,516] 0.85ms]
  509.  
  510.  
  511. SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["","10.0.0.251",24,516] 0.66ms]
  512.  
  513.  
  514. .
  515. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntNetMask.127.0.0.1']
  516.  
  517. *  
  518.  
  519.  
  520.  
  521. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [23,"1"] 0.95ms]
  522.  
  523.  
  524. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,"1"] 0.64ms]
  525.  
  526.  
  527. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.74ms]
  528.  
  529.  
  530. SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? ["","127.0.0.0\/8"] 0.51ms]
  531.  
  532.  
  533. s
  534. SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.62ms]
  535.  
  536.  
  537. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ?  ["127.0.0.1",8,515] 0.63ms]
  538.  
  539.  
  540. SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["","127.0.0.1",8,515] 0.53ms]
  541.  
  542.  
  543. .
  544. SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [23] 0.98ms]
  545.  
  546.  
  547.  
  548.  
  549.  
  550. >> Runtime for discovery module 'ipv4-addresses': 0.1150 seconds with 122024 bytes
  551.  
  552. >> SNMP: [3/0.10s] MySQL: [16/0.12s] RRD: [0/0.00s]  
  553.  
  554. #### Unload disco module ipv4-addresses ####
  555.  
  556. Modules status: Global+  
  557.  
  558. OS  
  559. Device  
  560.  
  561.  
  562. #### Load disco module ipv6-addresses ####
  563.  
  564. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6']
  565.  
  566. ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" 1
  567. ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:02:06:67:ff:fe:41:b3:93" 2  
  568.  
  569.  
  570.  
  571.  
  572. Warning: Undefined variable $ipv6_address in /opt/librenms/includes/discovery/ipv6-addresses.inc.php on line 30
  573.  
  574. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.5.2.16.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1']
  575.  
  576. IP-MIB::ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = OID: IP-MIB::ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128  
  577.  
  578.  
  579.  
  580. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.6.2.16.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1']
  581.  
  582. manual  
  583.  
  584.  
  585.  
  586. Warning: Undefined variable $ipv6_address in /opt/librenms/includes/discovery/ipv6-addresses.inc.php on line 30
  587.  
  588. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.5.2.16.254.128.0.0.0.0.0.0.2.6.103.255.254.65.179.147']
  589.  
  590. IP-MIB::ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:02:06:67:ff:fe:41:b3:93" = OID: IP-MIB::ipAddressPrefixOrigin.2.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64  
  591.  
  592.  
  593.  
  594. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.6.2.16.254.128.0.0.0.0.0.0.2.6.103.255.254.65.179.147']
  595.  
  596. linklayer  
  597.  
  598.  
  599.  
  600. SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [23] 0.98ms]
  601.  
  602.  
  603.  
  604.  
  605.  
  606. >> Runtime for discovery module 'ipv6-addresses': 0.1490 seconds with 544 bytes
  607. >> SNMP: [5/0.15s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  608.  
  609. #### Unload disco module ipv6-addresses ####
  610.  
  611. Modules status: Global-  
  612.  
  613. OS  
  614.  
  615. Device  
  616. Module [ route ] disabled globally.
  617.  
  618. Modules status: Global+  
  619.  
  620. OS  
  621.  
  622. Device  
  623.  
  624. #### Load disco module sensors ####
  625.  
  626. Pre-cache poweralert:
  627. tlUpsSnmpCardSerialNum
  628. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'TRIPPLITE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.100.1.1.4.0']
  629.  
  630. No Such Object available on this agent at this OID  
  631.  
  632.  
  633.  
  634.  
  635. array (
  636.   'poweralert_serial' => '',
  637. )  
  638. Caching data: os sensors
  639. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpPduInputPhaseVoltage']
  640.  
  641. tlpPduInputPhaseVoltage = No Such Instance currently exists at this OID  
  642.  
  643. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  644.  
  645. Invalid snmp_walk() data = tlpPduInputPhaseVoltage = No Such Instance currently exists at this OID  
  646.  
  647. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpAtsInputPhaseVoltage']
  648.  
  649. tlpAtsInputPhaseVoltage.1.1.1 = 1160
  650. tlpAtsInputPhaseVoltage.1.1.2 = 1172  
  651.  
  652. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  653.  
  654. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpPduCircuitTotalCurrent']
  655.  
  656. tlpPduCircuitTotalCurrent = No Such Instance currently exists at this OID  
  657.  
  658. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  659.  
  660. Invalid snmp_walk() data = tlpPduCircuitTotalCurrent = No Such Instance currently exists at this OID  
  661.  
  662. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpAtsOutputCurrent']
  663.  
  664. tlpAtsOutputCurrent = No Such Instance currently exists at this OID  
  665.  
  666. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  667.  
  668. Invalid snmp_walk() data = tlpAtsOutputCurrent = No Such Instance currently exists at this OID  
  669.  
  670. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlEnvHumidity']
  671.  
  672. tlEnvHumidity = No Such Object available on this agent at this OID  
  673.  
  674. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  675.  
  676. Invalid snmp_walk() data = tlEnvHumidity = No Such Object available on this agent at this OID  
  677.  
  678. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlEnvTemperatureC']
  679.  
  680. tlEnvTemperatureC = No Such Object available on this agent at this OID  
  681.  
  682. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  683.  
  684. Invalid snmp_walk() data = tlEnvTemperatureC = No Such Object available on this agent at this OID  
  685.  
  686. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlUpsBatteryAge']
  687.  
  688. tlUpsBatteryAge = No Such Object available on this agent at this OID  
  689.  
  690. Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X  
  691.  
  692. Invalid snmp_walk() data = tlUpsBatteryAge = No Such Object available on this agent at this OID  
  693.  
  694.  
  695.  
  696. Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/sensors/cisco-entity-sensor.inc.php on line 5
  697.  
  698.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescr
  699. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'entPhysicalDescr']
  700.  
  701. entPhysicalDescr = No Such Object available on this agent at this OID  
  702.  
  703.  
  704.  
  705. Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID  
  706.  
  707.  
  708. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",23,"ipmi"] 2.32ms]
  709.  
  710.  
  711. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",23,"ipmi"] 0.99ms]
  712.  
  713.  
  714. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",23,"ipmi"] 0.94ms]
  715.  
  716.  
  717. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",23,"ipmi"] 0.93ms]
  718.  
  719.  
  720. Airflow:
  721. array (
  722. )  
  723.  
  724. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",23,"snmp"] 0.95ms]
  725.  
  726.  
  727.  
  728. Current:
  729. RFC1628
  730. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryCurrent.0']
  731.  
  732. No Such Instance currently exists at this OID  
  733.  
  734.  
  735.  
  736. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputCurrent']
  737.  
  738. upsOutputCurrent = No Such Instance currently exists at this OID  
  739.  
  740.  
  741.  
  742. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputCurrent']
  743.  
  744. upsInputCurrent = No Such Instance currently exists at this OID  
  745.  
  746.  
  747.  
  748. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassCurrent']
  749.  
  750. upsBypassCurrent = No Such Instance currently exists at this OID  
  751.  
  752.  
  753.  
  754. Dynamic Discovery (current):  
  755.  
  756. array (
  757.   'data' =>
  758.   array (
  759.     0 =>
  760.     array (
  761.       'oid' => 'tlpPduCircuitTotalCurrent',
  762.       'num_oid' => '.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4.{{ $index }}',
  763.       'index' => 'tlpPduCircuitTotalCurrent.{{ $index }}',
  764.       'divisor' => 100,
  765.       'descr' => 'Current',
  766.     ),
  767.     1 =>
  768.     array (
  769.       'oid' => 'tlpAtsOutputCurrent',
  770.       'num_oid' => '.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5.1.{{ $index }}',
  771.       'descr' => 'Current',
  772.       'divisor' => 100,
  773.     ),
  774.   ),
  775. )  
  776.  
  777. Data tlpPduCircuitTotalCurrent:  
  778. array (
  779. )  
  780. Data tlpAtsOutputCurrent:  
  781. array (
  782. )  
  783.  
  784. array (
  785. )  
  786.  
  787. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",23,"snmp"] 1.45ms]
  788.  
  789.  
  790.  
  791. Charge:
  792. RFC1628
  793. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OvqU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsEstimatedChargeRemaining.0']
  794.  
  795. No Such Instance currently exists at this OID  
  796.  
  797.  
  798.  
  799. array (
  800. )  
  801.  
  802. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",23,"snmp"] 1.43ms]
  803.  
  804.  
  805.  
  806. Dbm:
  807. array (
  808. )  
  809.  
  810. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",23,"snmp"] 1.02ms]
  811.  
  812.  
  813.  
  814. Fanspeed:
  815. array (
  816. )  
  817.  
  818. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",23,"snmp"] 0.97ms]
  819.  
  820.  
  821.  
  822. Frequency:
  823. RFC1628
  824. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputFrequency']
  825.  
  826. upsInputFrequency = No Such Instance currently exists at this OID  
  827.  
  828.  
  829.  
  830. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputFrequency.0']
  831.  
  832. No Such Instance currently exists at this OID  
  833.  
  834.  
  835.  
  836. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassFrequency.0']
  837.  
  838. No Such Instance currently exists at this OID  
  839.  
  840.  
  841.  
  842. array (
  843. )  
  844.  
  845. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",23,"snmp"] 1.37ms]
  846.  
  847.  
  848.  
  849. Humidity:
  850. Dynamic Discovery (humidity):  
  851.  
  852. array (
  853.   'data' =>
  854.   array (
  855.     0 =>
  856.     array (
  857.       'oid' => 'tlEnvHumidity',
  858.       'num_oid' => '.1.3.6.1.4.1.850.101.1.2.1.{{ $index }}',
  859.       'descr' => 'Ambient Humidity',
  860.       'divisor' => 10,
  861.       'multiplier' => 10,
  862.       'low_limit' => 10,
  863.       'high_limit' => 90,
  864.       'group' => 'EnviroSense',
  865.       'skip_values' =>
  866.       array (
  867.         0 =>
  868.         array (
  869.           'oid' => 'tlEnvHumidity',
  870.           'op' => 'exists',
  871.           'value' => false,
  872.         ),
  873.       ),
  874.     ),
  875.   ),
  876. )  
  877. Data tlEnvHumidity:  
  878. array (
  879. )  
  880. array (
  881. )  
  882.  
  883. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",23,"snmp"] 1.29ms]
  884.  
  885.  
  886.  
  887. Load:
  888. RFC1628
  889. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputPercentLoad']
  890.  
  891. upsOutputPercentLoad = No Such Instance currently exists at this OID  
  892.  
  893.  
  894.  
  895. array (
  896. )  
  897.  
  898. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",23,"snmp"] 1.39ms]
  899.  
  900.  
  901.  
  902. Loss:
  903. array (
  904. )  
  905.  
  906. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["loss",23,"snmp"] 1.02ms]
  907.  
  908.  
  909.  
  910. Power:
  911. RFC1628
  912. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputPower']
  913.  
  914. upsOutputPower = No Such Instance currently exists at this OID  
  915.  
  916.  
  917.  
  918. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputTruePower']
  919.  
  920. upsInputTruePower = No Such Instance currently exists at this OID  
  921.  
  922.  
  923.  
  924. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassPower']
  925.  
  926. upsBypassPower = No Such Instance currently exists at this OID  
  927.  
  928.  
  929.  
  930. array (
  931. )  
  932.  
  933. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",23,"snmp"] 1.59ms]
  934.  
  935.  
  936.  
  937. Power_consumed:
  938. array (
  939. )  
  940.  
  941. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",23,"snmp"] 1.13ms]
  942.  
  943.  
  944.  
  945. Power_factor:
  946. array (
  947. )  
  948.  
  949. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",23,"snmp"] 1.15ms]
  950.  
  951.  
  952.  
  953. Runtime:
  954. RFC1628
  955. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.2.2.0']
  956.  
  957. No Such Instance currently exists at this OID  
  958.  
  959.  
  960.  
  961. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.2.3.0']
  962.  
  963. No Such Instance currently exists at this OID  
  964.  
  965.  
  966.  
  967. array (
  968. )  
  969.  
  970. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",23,"snmp"] 1.47ms]
  971.  
  972.  
  973.  
  974. Signal:
  975. array (
  976. )  
  977.  
  978. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",23,"snmp"] 1ms]
  979.  
  980.  
  981.  
  982. State:
  983. RFC1628
  984. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqe' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryStatus.0']
  985.  
  986. No Such Instance currently exists at this OID  
  987.  
  988.  
  989.  
  990. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqe' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputSource.0']
  991.  
  992. No Such Instance currently exists at this OID  
  993.  
  994.  
  995.  
  996. array (
  997. )  
  998.  
  999. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",23,"snmp"] 1.37ms]
  1000.  
  1001.  
  1002.  
  1003. Count:
  1004. Dynamic Discovery (count):  
  1005.  
  1006. array (
  1007.   'data' =>
  1008.   array (
  1009.     0 =>
  1010.     array (
  1011.       'oid' => 'tlUpsBatteryAge',
  1012.       'num_oid' => '.1.3.6.1.4.1.850.100.1.2.1.{{ $index }}',
  1013.       'descr' => 'Battery Age (Years)',
  1014.     ),
  1015.   ),
  1016. )  
  1017. Data tlUpsBatteryAge:  
  1018.  
  1019. array (
  1020. )  
  1021.  
  1022. array (
  1023. )  
  1024.  
  1025. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",23,"snmp"] 0.98ms]
  1026.  
  1027.  
  1028.  
  1029. Temperature:
  1030. RFC1628
  1031. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryTemperature.0']
  1032.  
  1033. No Such Instance currently exists at this OID  
  1034.  
  1035.  
  1036.  
  1037. Dynamic Discovery (temperature):  
  1038.  
  1039. array (
  1040.   'data' =>
  1041.   array (
  1042.     0 =>
  1043.     array (
  1044.       'oid' => 'tlEnvTemperatureC',
  1045.       'num_oid' => '.1.3.6.1.4.1.850.101.1.1.1.{{ $index }}',
  1046.       'descr' => 'Ambient Temperature',
  1047.       'divisor' => 10,
  1048.       'multiplier' => 10,
  1049.       'low_limit' => 0,
  1050.       'high_limit' => 40,
  1051.       'group' => 'EnviroSense',
  1052.       'skip_values' =>
  1053.       array (
  1054.         0 =>
  1055.         array (
  1056.           'oid' => 'tlEnvTemperatureC',
  1057.           'op' => 'exists',
  1058.           'value' => false,
  1059.         ),
  1060.       ),
  1061.     ),
  1062.   ),
  1063. )  
  1064. Data tlEnvTemperatureC:  
  1065.  
  1066. array (
  1067. )  
  1068.  
  1069. array (
  1070. )  
  1071.  
  1072. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",23,"snmp"] 1.45ms]
  1073.  
  1074.  
  1075.  
  1076. Tv_signal:
  1077. array (
  1078. )  
  1079.  
  1080. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["tv_signal",23,"snmp"] 1.19ms]
  1081.  
  1082.  
  1083.  
  1084. Bitrate:
  1085. array (
  1086. )  
  1087.  
  1088. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["bitrate",23,"snmp"] 1.08ms]
  1089.  
  1090.  
  1091.  
  1092. Voltage:
  1093. RFC1628
  1094. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryVoltage.0']
  1095.  
  1096. No Such Instance currently exists at this OID  
  1097.  
  1098.  
  1099.  
  1100. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputVoltage']
  1101.  
  1102. upsOutputVoltage = No Such Instance currently exists at this OID  
  1103.  
  1104.  
  1105.  
  1106. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputVoltage']
  1107.  
  1108. upsInputVoltage = No Such Instance currently exists at this OID  
  1109.  
  1110.  
  1111.  
  1112. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassVoltage']
  1113.  
  1114. upsBypassVoltage = No Such Instance currently exists at this OID  
  1115.  
  1116.  
  1117.  
  1118. Dynamic Discovery (voltage):  
  1119. array (
  1120.   'data' =>
  1121.   array (
  1122.     0 =>
  1123.     array (
  1124.       'oid' => 'tlpPduInputPhaseVoltage',
  1125.       'num_oid' => '.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4.{{ $index }}',
  1126.       'descr' => 'Input',
  1127.       'divisor' => 10,
  1128.       'multiplier' => 1,
  1129.       'low_limit' => 110,
  1130.       'high_limit' => 240,
  1131.     ),
  1132.     1 =>
  1133.     array (
  1134.       'oid' => 'tlpAtsInputPhaseVoltage',
  1135.       'num_oid' => '.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.{{ $index }}',
  1136.       'descr' => 'Input',
  1137.       'divisor' => 10,
  1138.       'multiplier' => 1,
  1139.       'low_limit' => 110,
  1140.       'high_limit' => 240,
  1141.     ),
  1142.   ),
  1143. )  
  1144.  
  1145. Data tlpPduInputPhaseVoltage:  
  1146. array (
  1147. )  
  1148.  
  1149. Data tlpAtsInputPhaseVoltage:  
  1150.  
  1151. array (
  1152.   '1.1.1' =>
  1153.   array (
  1154.     'tlpAtsInputPhaseVoltage' => '1160',
  1155.   ),
  1156.   '1.1.2' =>
  1157.   array (
  1158.     'tlpAtsInputPhaseVoltage' => '1172',
  1159.   ),
  1160. )  
  1161.  
  1162. Sensor fetched value: 1160  
  1163.  
  1164. Cur 116, Low: 110, Low Warn: null, Warn: null, High: 240
  1165.  
  1166. Discover sensor: .1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.1.1.1, 1.1.1, poweralert, Input, snmp, 10, 1, , 116, (limits: LL: 110, LW: , W: , H: 240)  
  1167.  
  1168. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",23,"poweralert","1.1.1"] 1.25ms]
  1169.  
  1170.  
  1171. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",23,"poweralert","1.1.1"] 0.84ms]
  1172.  
  1173.  
  1174. .
  1175. Sensor fetched value: 1172  
  1176. Cur 117.2, Low: 110, Low Warn: null, Warn: null, High: 240
  1177.  
  1178. Discover sensor: .1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.1.1.2, 1.1.2, poweralert, Input, snmp, 10, 1, , 117.2, (limits: LL: 110, LW: , W: , H: 240)  
  1179.  
  1180. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",23,"poweralert","1.1.2"] 0.77ms]
  1181.  
  1182.  
  1183. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",23,"poweralert","1.1.2"] 0.84ms]
  1184.  
  1185.  
  1186. .
  1187. array (
  1188.   'poweralert' =>
  1189.   array (
  1190.     '1.1.1' => 1,
  1191.     '1.1.2' => 1,
  1192.   ),
  1193. )  
  1194.  
  1195. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",23,"snmp"] 1.09ms]
  1196.  
  1197.  
  1198. 1.1.1 -> poweralert  
  1199. 1.1.2 -> poweralert  
  1200.  
  1201. Snr:
  1202. array (
  1203. )  
  1204.  
  1205. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",23,"snmp"] 1.02ms]
  1206.  
  1207.  
  1208.  
  1209. Pressure:
  1210. array (
  1211. )  
  1212.  
  1213. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",23,"snmp"] 1.01ms]
  1214.  
  1215.  
  1216.  
  1217. Cooling:
  1218. array (
  1219. )  
  1220.  
  1221. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",23,"snmp"] 0.94ms]
  1222.  
  1223.  
  1224.  
  1225. Delay:
  1226. array (
  1227. )  
  1228.  
  1229. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",23,"snmp"] 0.94ms]
  1230.  
  1231.  
  1232.  
  1233. Quality_factor:
  1234. array (
  1235. )  
  1236.  
  1237. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",23,"snmp"] 0.97ms]
  1238.  
  1239.  
  1240.  
  1241. Chromatic_dispersion:
  1242. array (
  1243. )  
  1244.  
  1245. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",23,"snmp"] 0.93ms]
  1246.  
  1247.  
  1248.  
  1249. Ber:
  1250. array (
  1251. )  
  1252.  
  1253. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",23,"snmp"] 0.95ms]
  1254.  
  1255.  
  1256.  
  1257. Eer:
  1258. array (
  1259. )  
  1260.  
  1261. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",23,"snmp"] 0.98ms]
  1262.  
  1263.  
  1264.  
  1265. Waterflow:
  1266. array (
  1267. )  
  1268.  
  1269. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",23,"snmp"] 0.94ms]
  1270.  
  1271.  
  1272.  
  1273. Percent:
  1274. array (
  1275. )  
  1276.  
  1277. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["percent",23,"snmp"] 0.93ms]
  1278.  
  1279.  
  1280.  
  1281.  
  1282.  
  1283. >> Runtime for discovery module 'sensors': 1.3470 seconds with 8168 bytes
  1284.  
  1285. >> SNMP: [19/0.75s] MySQL: [38/0.43s] RRD: [0/0.00s]  
  1286.  
  1287. #### Unload disco module sensors ####
  1288.  
  1289.  
  1290. Modules status: Global+  
  1291. OS  
  1292.  
  1293. Device  
  1294.  
  1295. #### Load disco module storage ####
  1296.  
  1297. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'aixFsTableEntry']
  1298.  
  1299. Exitcode: 1  
  1300.  
  1301. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1302. Cannot find module (IBM-AIX-MIB): At line 65 in (none)
  1303. aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)  
  1304.  
  1305.  
  1306. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1307. Cannot find module (IBM-AIX-MIB): At line 65 in (none)
  1308. aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)  
  1309. aix_filesystem :
  1310. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable']
  1311.  
  1312. fileSystemSpaceTable = No Such Object available on this agent at this OID  
  1313.  
  1314.  
  1315.  
  1316. Invalid snmp_walk() data = fileSystemSpaceTable = No Such Object available on this agent at this OID  
  1317.  
  1318. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'datasetTable']
  1319.  
  1320. Exitcode: 1  
  1321.  
  1322. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1323. Cannot find module (FREENAS-MIB): At line 65 in (none)
  1324. datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)  
  1325.  
  1326.  
  1327. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1328. Cannot find module (FREENAS-MIB): At line 65 in (none)
  1329. datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)  
  1330.  
  1331. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id`  = '23' AND `storage_type` != 'dataset' [] 1.04ms]
  1332.  
  1333.  
  1334. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'zpoolTable']
  1335.  
  1336. Exitcode: 1  
  1337.  
  1338. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1339. Cannot find module (FREENAS-MIB): At line 65 in (none)
  1340. zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)  
  1341.  
  1342.  
  1343. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1344. Cannot find module (FREENAS-MIB): At line 65 in (none)
  1345. zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)  
  1346.  
  1347. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id`  = '23' AND `storage_type` != 'zpool' [] 0.97ms]
  1348.  
  1349.  
  1350.  
  1351. Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/storage/hpe-ilo.inc.php on line 3
  1352.  
  1353. hrStorage :
  1354. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dskTable']
  1355.  
  1356. dskTable = No Such Object available on this agent at this OID  
  1357.  
  1358.  
  1359.  
  1360. Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID  
  1361.  
  1362. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id`  = '23' AND `storage_type` != 'dsk' [] 0.89ms]
  1363.  
  1364.  
  1365.  
  1366. Warning: Undefined variable $valid_storage in /opt/librenms/includes/discovery/storage.inc.php on line 10
  1367.  
  1368.  
  1369.  
  1370. SQL[SELECT * FROM `storage` WHERE `device_id`  = '23' [] 0.62ms]
  1371.  
  1372.  
  1373.  
  1374.  
  1375.  
  1376. >> Runtime for discovery module 'storage': 0.1410 seconds with 1920 bytes
  1377. >> SNMP: [5/0.13s] MySQL: [4/0.04s] RRD: [0/0.00s]  
  1378.  
  1379. #### Unload disco module storage ####
  1380.  
  1381. Modules status: Global+  
  1382.  
  1383. OS  
  1384.  
  1385. Device  
  1386.  
  1387. #### Load disco module hr-device ####
  1388.  
  1389.  
  1390. Warning: Undefined variable $hrDevices in /opt/librenms/includes/discovery/hr-device.inc.php on line 7
  1391.  
  1392.  
  1393.  
  1394. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrDeviceEntry']
  1395.  
  1396. hrDeviceEntry = No Such Object available on this agent at this OID  
  1397.  
  1398.  
  1399.  
  1400. Invalid snmp_walk() data = hrDeviceEntry = No Such Object available on this agent at this OID  
  1401.  
  1402. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrProcessorEntry']
  1403.  
  1404. hrProcessorEntry = No Such Object available on this agent at this OID  
  1405.  
  1406.  
  1407. Invalid snmp_walk() data = hrProcessorEntry = No Such Object available on this agent at this OID  
  1408. array (
  1409. )  
  1410.  
  1411. SQL[SELECT * FROM `hrDevice` WHERE `device_id`  = '23' [] 1.08ms]
  1412.  
  1413.  
  1414.  
  1415.  
  1416.  
  1417. >> Runtime for discovery module 'hr-device': 0.1130 seconds with 0 bytes
  1418. >> SNMP: [2/0.11s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  1419.  
  1420. #### Unload disco module hr-device ####
  1421.  
  1422. Modules status: Global+  
  1423.  
  1424. OS  
  1425.  
  1426. Device  
  1427.  
  1428. #### Load disco module discovery-protocols ####
  1429.  
  1430.  CISCO-CDP-MIB:
  1431. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'cdpCache']
  1432.  
  1433. Exitcode: 1  
  1434.  
  1435. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1436. Cannot find module (CISCO-CDP-MIB): At line 65 in (none)
  1437. cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache)  
  1438.  
  1439.  
  1440. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
  1441. Cannot find module (CISCO-CDP-MIB): At line 65 in (none)
  1442. cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache)  
  1443.  
  1444.  LLDP-MIB:
  1445. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'lldpRemTable']
  1446.  
  1447. lldpRemTable = No Such Object available on this agent at this OID  
  1448.  
  1449.  
  1450.  
  1451.  
  1452.  
  1453.  OSPF Discovery:
  1454. SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [23] 1.13ms]
  1455.  
  1456.  
  1457.  
  1458.  
  1459.  
  1460.  
  1461. SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [23] 1.07ms]
  1462.  
  1463.  
  1464. SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 0.62ms]
  1465.  
  1466.  
  1467.  0 orphaned links deleted  
  1468.  
  1469. >> Runtime for discovery module 'discovery-protocols': 0.0640 seconds with 48 bytes
  1470.  
  1471. >> SNMP: [0/0.00s] MySQL: [3/0.03s] RRD: [0/0.00s]  
  1472.  
  1473. #### Unload disco module discovery-protocols ####
  1474.  
  1475.  
  1476. Modules status: Global+  
  1477. OS  
  1478.  
  1479. Device  
  1480.  
  1481. #### Load disco module arp-table ####
  1482.  
  1483. SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress']  
  1484.  
  1485. IP-MIB::ipNetToPhysicalPhysAddress = No Such Instance currently exists at this OID
  1486.  
  1487.  
  1488.  
  1489.  
  1490. SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress']  
  1491.  
  1492. IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:be:66:59
  1493. IP-MIB::ipNetToMediaPhysAddress[2][*] = 68:5:ca:ae:38:2d
  1494. IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:79:2d:2a
  1495. IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:e0:8d:6a
  1496. IP-MIB::ipNetToMediaPhysAddress[2][*] = f0:9f:c2:1a:5b:8f
  1497.  
  1498.  
  1499.  
  1500.  
  1501. SQL[SELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [23,""] 1.16ms]
  1502.  
  1503.  
  1504. SQL[SELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,2] 0.91ms]
  1505.  
  1506.  
  1507.  
  1508. Warning: Undefined array key "IP-MIB::ipNetToPhysicalPhysAddress" in /opt/librenms/includes/discovery/arp-table.inc.php on line 50
  1509. eth0:
  1510. 0:c:29:be:66:59 => 10.0.0.5  
  1511.  
  1512. 68:5:ca:ae:38:2d => 10.0.0.86  
  1513. 0:c:29:79:2d:2a => 10.0.0.120  
  1514.  
  1515. 0:c:29:e0:8d:6a => 10.0.0.221  
  1516.  
  1517. f0:9f:c2:1a:5b:8f => 10.0.0.254  
  1518.  
  1519.  
  1520. SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [] 1.31ms]
  1521.  
  1522.  
  1523.  
  1524.  
  1525.  
  1526. >> Runtime for discovery module 'arp-table': 0.0950 seconds with 13648 bytes
  1527. >> SNMP: [2/0.09s] MySQL: [3/0.03s] RRD: [0/0.00s]  
  1528.  
  1529. #### Unload disco module arp-table ####
  1530.  
  1531. Modules status: Global-  
  1532.  
  1533. OS  
  1534. Device  
  1535. Module [ discovery-arp ] disabled globally.
  1536.  
  1537.  
  1538. Modules status: Global-  
  1539. OS  
  1540. Device  
  1541. Module [ junose-atm-vp ] disabled globally.
  1542.  
  1543.  
  1544. Modules status: Global+  
  1545.  
  1546. OS  
  1547. Device  
  1548.  
  1549. #### Load disco module bgp-peers ####
  1550.  
  1551. SNMP['/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'bgpLocalAs']
  1552.  
  1553. "15.5.5 (Build 1069)"  
  1554.  
  1555.  
  1556.  
  1557. No BGP on host
  1558. Warning: Undefined variable $peers_data in /opt/librenms/includes/discovery/bgp-peers.inc.php on line 55
  1559.  
  1560. Warning: Undefined variable $peer2 in /opt/librenms/includes/discovery/bgp-peers.inc.php on line 55
  1561. Peers :  
  1562.  
  1563. Warning: Undefined array key 1 in /opt/librenms/includes/discovery/functions.inc.php on line 1026
  1564.  
  1565. SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [23,""] 0.78ms]
  1566.  
  1567.  
  1568. SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [23,""] 0.52ms]
  1569.  
  1570.  
  1571.  
  1572.  
  1573. SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [23] 0.65ms]
  1574.  
  1575.  
  1576.  
  1577. >> Runtime for discovery module 'bgp-peers': 0.0250 seconds with 632 bytes
  1578.  
  1579. >> SNMP: [1/0.02s] MySQL: [3/0.02s] RRD: [0/0.00s]  
  1580. #### Unload disco module bgp-peers ####
  1581.  
  1582.  
  1583. Modules status: Global+  
  1584. OS  
  1585.  
  1586. Device  
  1587.  
  1588.  
  1589. #### Load disco module vlans ####
  1590.  
  1591. SQL[SELECT * FROM `vlans` WHERE `device_id` = ? [23] 0.65ms]
  1592.  
  1593.  
  1594. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex']
  1595.  
  1596. dot1dBasePortIfIndex = No Such Object available on this agent at this OID  
  1597.  
  1598.  
  1599.  
  1600. Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID  
  1601.  
  1602. IEEE8021-Q-BRIDGE-MIB VLANs:
  1603. SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0']
  1604.  
  1605. No Such Object available on this agent at this OID  
  1606.  
  1607.  
  1608.  
  1609.  
  1610.  
  1611.  
  1612. Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/vlans/cisco-vtp.inc.php on line 3
  1613.  
  1614.  
  1615. >> Runtime for discovery module 'vlans': 0.0860 seconds with 272 bytes
  1616.  
  1617. >> SNMP: [2/0.08s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  1618.  
  1619. #### Unload disco module vlans ####
  1620.  
  1621.  
  1622. Modules status: Global-  
  1623. OS  
  1624.  
  1625. Device  
  1626. Module [ vmware-vminfo ] disabled globally.
  1627.  
  1628.  
  1629. Modules status: Global-  
  1630.  
  1631. OS  
  1632. Device  
  1633. Module [ libvirt-vminfo ] disabled globally.
  1634.  
  1635. Modules status: Global-  
  1636.  
  1637. OS  
  1638.  
  1639. Device  
  1640. Module [ printer-supplies ] disabled globally.
  1641.  
  1642.  
  1643. Modules status: Global+  
  1644. OS  
  1645. Device  
  1646.  
  1647. #### Load disco module ucd-diskio ####
  1648.  
  1649. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'diskIOEntry']
  1650.  
  1651. diskIOEntry = No Such Object available on this agent at this OID  
  1652.  
  1653.  
  1654.  
  1655. Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID  
  1656. array (
  1657. )  
  1658.  
  1659. SQL[SELECT * FROM `ucd_diskio` where `device_id`  = '23' [] 0.96ms]
  1660.  
  1661.  
  1662.  
  1663.  
  1664. >> Runtime for discovery module 'ucd-diskio': 0.0290 seconds with 160 bytes
  1665.  
  1666. >> SNMP: [1/0.03s] MySQL: [1/0.01s] RRD: [0/0.00s]  
  1667.  
  1668. #### Unload disco module ucd-diskio ####
  1669.  
  1670.  
  1671. Modules status: Global-  
  1672. OS  
  1673. Device  
  1674. Module [ applications ] disabled globally.
  1675.  
  1676.  
  1677. Modules status: Global+  
  1678. OS  
  1679.  
  1680. Device  
  1681.  
  1682. #### Load disco module services ####
  1683.  
  1684.  
  1685. >> Runtime for discovery module 'services': 0.0000 seconds with 80 bytes
  1686.  
  1687. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]  
  1688.  
  1689. #### Unload disco module services ####
  1690.  
  1691.  
  1692. Modules status: Global+  
  1693. OS  
  1694. Device  
  1695.  
  1696. #### Load disco module stp ####
  1697.  
  1698. Instances:
  1699. SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0']  
  1700.  
  1701. BRIDGE-MIB::dot1dStpProtocolSpecification.0 = No Such Object available on this agent at this OID
  1702.  
  1703.  
  1704.  
  1705.  
  1706. SQL[select * from `stp` where `stp`.`device_id` = ? and `stp`.`device_id` is not null [23] 1.09ms]
  1707.  
  1708.  
  1709.  
  1710. Ports:
  1711. SQL[select * from `ports_stp` where `ports_stp`.`device_id` = ? and `ports_stp`.`device_id` is not null [23] 0.68ms]
  1712.  
  1713.  
  1714.  
  1715.  
  1716.  
  1717. >> Runtime for discovery module 'stp': 0.0460 seconds with 61872 bytes
  1718.  
  1719. >> SNMP: [1/0.04s] MySQL: [2/0.02s] RRD: [0/0.00s]  
  1720. #### Unload disco module stp ####
  1721.  
  1722.  
  1723. Modules status: Global+  
  1724. OS  
  1725.  
  1726. Device  
  1727.  
  1728. #### Load disco module ntp ####
  1729.  
  1730.  
  1731. Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/ntp.inc.php on line 30
  1732.  
  1733. >> Runtime for discovery module 'ntp': 0.0000 seconds with 80 bytes
  1734.  
  1735. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]  
  1736.  
  1737. #### Unload disco module ntp ####
  1738.  
  1739.  
  1740. Modules status: Global-  
  1741. OS  
  1742.  
  1743. Device  
  1744. Module [ loadbalancers ] disabled globally.
  1745.  
  1746.  
  1747. Modules status: Global-  
  1748.  
  1749. OS  
  1750. Device  
  1751. Module [ mef ] disabled globally.
  1752.  
  1753.  
  1754. Modules status: Global+  
  1755.  
  1756. OS  
  1757. Device  
  1758.  
  1759. #### Load disco module wireless ####
  1760.  
  1761. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ap-count"] 0.85ms]
  1762.  
  1763.  
  1764. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"clients"] 0.77ms]
  1765.  
  1766.  
  1767. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"quality"] 0.78ms]
  1768.  
  1769.  
  1770. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"capacity"] 0.72ms]
  1771.  
  1772.  
  1773. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"utilization"] 0.74ms]
  1774.  
  1775.  
  1776. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rate"] 0.72ms]
  1777.  
  1778.  
  1779. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ccq"] 0.76ms]
  1780.  
  1781.  
  1782. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"snr"] 0.72ms]
  1783.  
  1784.  
  1785. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"sinr"] 0.71ms]
  1786.  
  1787.  
  1788. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rsrp"] 0.73ms]
  1789.  
  1790.  
  1791. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rsrq"] 0.71ms]
  1792.  
  1793.  
  1794. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ssr"] 0.7ms]
  1795.  
  1796.  
  1797. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"mse"] 0.71ms]
  1798.  
  1799.  
  1800. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"xpi"] 0.75ms]
  1801.  
  1802.  
  1803. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rssi"] 0.72ms]
  1804.  
  1805.  
  1806. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"power"] 0.76ms]
  1807.  
  1808.  
  1809. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"noise-floor"] 0.76ms]
  1810.  
  1811.  
  1812. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"errors"] 0.73ms]
  1813.  
  1814.  
  1815. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"error-ratio"] 0.72ms]
  1816.  
  1817.  
  1818. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"error-rate"] 1.58ms]
  1819.  
  1820.  
  1821. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"frequency"] 0.74ms]
  1822.  
  1823.  
  1824. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"distance"] 0.73ms]
  1825.  
  1826.  
  1827. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"cell"] 0.75ms]
  1828.  
  1829.  
  1830. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"channel"] 0.7ms]
  1831.  
  1832.  
  1833.  
  1834. >> Runtime for discovery module 'wireless': 0.0310 seconds with 10600 bytes
  1835.  
  1836. >> SNMP: [0/0.00s] MySQL: [24/0.19s] RRD: [0/0.00s]  
  1837.  
  1838. #### Unload disco module wireless ####
  1839.  
  1840. Modules status: Global+  
  1841. OS  
  1842.  
  1843. Device  
  1844.  
  1845. #### Load disco module fdb-table ####
  1846.  
  1847. SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [23] 0.6ms]
  1848.  
  1849.  
  1850. SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = ? [23] 0.62ms]
  1851.  
  1852.  
  1853. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1qTpFdbPort']
  1854.  
  1855. dot1qTpFdbPort = No Such Object available on this agent at this OID  
  1856.  
  1857.  
  1858.  
  1859. SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1dTpFdbPort']
  1860.  
  1861. dot1dTpFdbPort = No Such Object available on this agent at this OID  
  1862.  
  1863.  
  1864.  
  1865.  
  1866.  
  1867.  
  1868. >> Runtime for discovery module 'fdb-table': 0.1220 seconds with 144 bytes
  1869. >> SNMP: [0/0.00s] MySQL: [2/0.01s] RRD: [0/0.00s]  
  1870.  
  1871. #### Unload disco module fdb-table ####
  1872.  
  1873.  
  1874. Modules status: Global+  
  1875. OS  
  1876. Device  
  1877.  
  1878. #### Load disco module mpls ####
  1879.  
  1880.  
  1881. >> Runtime for discovery module 'mpls': 0.0000 seconds with 488 bytes
  1882.  
  1883. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]  
  1884.  
  1885. #### Unload disco module mpls ####
  1886.  
  1887.  
  1888. SQL[UPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [4.217,23] 1.2ms]
  1889.  
  1890.  
  1891. Discovered in 4.217 seconds
  1892.  
  1893.  
  1894. /opt/librenms/discovery.php 10.0.0.251 2022-09-12 14:55:09 - 1 devices discovered in 4.559 secs  
  1895.  
  1896.  
  1897. SNMP [58/2.14s]: Snmpget[29/0.94s] Snmpwalk[28/1.18s] Snmpgetnext[1/0.02s]  
  1898.  
  1899. SQL [118/1.78s]: Select[106/1.69s] Update[7/0.05s] Delete[5/0.04s]  
  1900.  
  1901. RRD [0/0.00s]:  