LibreNMS Discovery SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 0.73ms] SQL[select count(*) as aggregate from `migrations` limit 1 [] 1.02ms] SQL[select version() [] 0.69ms] =================================== Version info: Commit SHA: Commit Date: DB Schema: 2022_07_19_081224_plugins_unique_index (244) PHP: 8.0.22 Database: MariaDB 10.5.17-MariaDB-1:10.5.17+maria~ubu2004 RRDTool: 1.7.2 SNMP: 5.9.3 ==================================DEBUG! Updating os_def.cache Warning: file_put_contents(/opt/librenms/cache/os_defs.cache): Failed to open stream: Permission denied in /opt/librenms/LibreNMS/Util/OS.php on line 111 SQL[SELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE '10.0.0.251' ORDER BY device_id DESC [] 1.36ms] SQL[select * from `devices` where `device_id` = ? limit 1 [23] 0.89ms] SQL[select * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [23] 0.88ms] 10.0.0.251 23 poweralert [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' '10.0.0.251' response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.594/0.607/0.627 SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'] SNMPv2-MIB::sysObjectID.0 = SNMPv2-SMI::enterprises.8* Modules status: Global+ OS Device #### Load disco module core #### Attempting to initialize OS: poweralert OS initialized: LibreNMS\OS\Poweralert SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0'] .*.*.0 = .*.4.1.8* .*.*.0 = Ubuntu 16.04.6 LTS Linux 4.4.31 flash: 3.4G ram: 506844kB processor: armv7l software: PowerAlert 15.5.5 (Build 1069) .*.*.0 = poweralert-0610365179147 | Ubuntu 16.04.6 LTS Linux 4.4.31 flash: 3.4G ram: 506844kB processor: armv7l software: PowerAlert 15.5.5 (Build 1069) | .1.3.6.1.4.1.850.1.1.1 | OS: Tripp Lite PowerAlert (poweralert) Attempting to initialize OS: poweralert OS initialized: LibreNMS\OS\Poweralert >> Runtime for discovery module 'core': 0.0660 seconds with 23360 bytes >> SNMP: [1/0.04s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS Device #### Load disco module os #### SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.100.1.1.6.0'] .*.4.1.8*.6.0 = No Such Object available on this agent at this OID Yaml location data: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'] SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'sysContact.0'] SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.10.2.2.1.9.2' '.1.3.6.1.2.1.33.1.1.2.0' '.1.3.6.1.4.1.850.100.1.1.2.0' '.1.3.6.1.2.1.33.1.1.4.0' '.1.3.6.1.2.1.33.1.1.3.0'] .*.4.1.8*.1.9.2 = No Such Object available on this agent at this OID .*.*.1.2.0 = No Such Instance currently exists at this OID .*.4.1.8*.2.0 = No Such Object available on this agent at this OID .*.*.1.4.0 = "15.5.5 (Build 1069)" .*.*.1.3.0 = No Such Instance currently exists at this OID Yaml OS data: {".1.3.6.1.2.1.33.1.1.4.0":"15.5.5 (Build 1069)"} SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.1.5.0'] SNMPv2-SMI::mib-*.5.0 = No Such Instance currently exists at this OID Location: Hardware: OS Version: 15.5.5 (Build 1069) OS Features: Serial: >> Runtime for discovery module 'os': 0.2020 seconds with 152864 bytes >> SNMP: [5/0.19s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifDescr'] ifDescr.1 = lo ifDescr.2 = eth0 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifName'] ifName = No Such Object available on this agent at this OID Invalid snmp_walk() data = ifName = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifAlias'] ifAlias = No Such Object available on this agent at this OID Invalid snmp_walk() data = ifAlias = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifType'] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifOperStatus'] ifOperStatus.1 = up ifOperStatus.2 = up array ( 1 => array ( 'ifDescr' => 'lo', 'ifType' => 'softwareLoopback', 'ifOperStatus' => 'up', ), 2 => array ( 'ifDescr' => 'eth0', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), ) SQL[SELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [23] 1.4ms] Warning: Undefined array key "ifAlias" in /opt/librenms/includes/discovery/ports.inc.php on line 84 Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 629 Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 703 Using ifDescr as ifAlias Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 712 Using ifDescr as ifName SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["lo","softwareLoopback","up",1,"lo","lo",515] 0.69ms] . Warning: Undefined array key "ifAlias" in /opt/librenms/includes/discovery/ports.inc.php on line 84 Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 629 Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 703 Using ifDescr as ifAlias Warning: Undefined array key "ifName" in /opt/librenms/includes/functions.php on line 712 Using ifDescr as ifName SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["eth0","ethernetCsmacd","up",2,"eth0","eth0",516] 0.62ms] . >> Runtime for discovery module 'ports': 0.1840 seconds with 4376 bytes >> SNMP: [5/0.18s] MySQL: [3/0.03s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '23' [] 0.74ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ifStackStatus'] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0540 seconds with 32 bytes >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntry SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'entPhysicalEntry'] entPhysicalEntry = No Such Object available on this agent at this OID MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 65 in (none) Invalid snmp_walk() data = entPhysicalEntry = No Such Object available on this agent at this OID SQL[SELECT * FROM `entPhysical` WHERE `device_id` = ? [23] 1ms] >> Runtime for discovery module 'entity-physical': 0.0380 seconds with 5840 bytes >> SNMP: [1/0.04s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS Device Module [ entity-state ] disabled globally. Modules status: Global- OS Device Module [ isis ] disabled globally. Modules status: Global+ OS Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrProcessorLoad'] hrProcessorLoad = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'] No Such Object available on this agent at this OID SQL[SELECT * FROM `processors` WHERE `device_id`=? [23] 1.03ms] SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 0.76ms] >> Runtime for discovery module 'processors': 0.1050 seconds with 24144 bytes >> SNMP: [2/0.10s] MySQL: [2/0.02s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrStorageTable'] hrStorageTable = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrMemorySize.0'] No Such Object available on this agent at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0'] memTotalSwap.0 = No Such Object available on this agent at this OID memAvailSwap.0 = No Such Object available on this agent at this OID memTotalReal.0 = No Such Object available on this agent at this OID memAvailReal.0 = No Such Object available on this agent at this OID memBuffer.0 = No Such Object available on this agent at this OID memCached.0 = No Such Object available on this agent at this OID memSysAvail.0 = No Such Object available on this agent at this OID SQL[select * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [23] 0.95ms] >> Runtime for discovery module 'mempools': 0.1090 seconds with 32480 bytes >> SNMP: [2/0.05s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/cisco-vrf-lite.inc.php on line 24 SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = ? [23] 0.67ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 80 bytes >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ slas ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global- OS Device Module [ cisco-qfp ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SQL[select * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [23] 0.84ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'] ipAdEntIfIndex.* 2 ipAdEntIfIndex.* 1 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.0.0.251'] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [23,"2"] 1.19ms] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,"2"] 0.82ms] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.0.0.0\/24"] 0.86ms] SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? ["","10.0.0.0\/24"] 0.75ms] s SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.0.0.0\/24"] 0.72ms] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["10.0.0.251",24,516] 0.85ms] SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["","10.0.0.251",24,516] 0.66ms] . SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAdEntNetMask.127.0.0.1'] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [23,"1"] 0.95ms] SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,"1"] 0.64ms] SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.74ms] SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? ["","127.0.0.0\/8"] 0.51ms] s SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.62ms] SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["127.0.0.1",8,515] 0.63ms] SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["","127.0.0.1",8,515] 0.53ms] . SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [23] 0.98ms] >> Runtime for discovery module 'ipv4-addresses': 0.1150 seconds with 122024 bytes >> SNMP: [3/0.10s] MySQL: [16/0.12s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'] ipAddressIfIndex.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" 1 ipAddressIfIndex.ipv6."fe:80:00:00:00:00:00:00:02:06:67:ff:fe:41:b3:93" 2 Warning: Undefined variable $ipv6_address in /opt/librenms/includes/discovery/ipv6-addresses.inc.php on line 30 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.5.2.16.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1'] IP-MIB::ipAddressPrefix.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01" = OID: IP-MIB::ipAddressPrefixOrigin.1.ipv6."00:00:00:00:00:00:00:00:00:00:00:00:00:00:00:01".128 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.6.2.16.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.1'] manual Warning: Undefined variable $ipv6_address in /opt/librenms/includes/discovery/ipv6-addresses.inc.php on line 30 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.5.2.16.254.128.0.0.0.0.0.0.2.6.103.255.254.65.179.147'] IP-MIB::ipAddressPrefix.ipv6."fe:80:00:00:00:00:00:00:02:06:67:ff:fe:41:b3:93" = OID: IP-MIB::ipAddressPrefixOrigin.2.ipv6."fe:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00".64 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.34.1.6.2.16.254.128.0.0.0.0.0.0.2.6.103.255.254.65.179.147'] linklayer SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [23] 0.98ms] >> Runtime for discovery module 'ipv6-addresses': 0.1490 seconds with 544 bytes >> SNMP: [5/0.15s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### Pre-cache poweralert: tlUpsSnmpCardSerialNum SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'TRIPPLITE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.850.100.1.1.4.0'] No Such Object available on this agent at this OID array ( 'poweralert_serial' => '', ) Caching data: os sensors SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpPduInputPhaseVoltage'] tlpPduInputPhaseVoltage = No Such Instance currently exists at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlpPduInputPhaseVoltage = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpAtsInputPhaseVoltage'] tlpAtsInputPhaseVoltage.1.1.1 = 1160 tlpAtsInputPhaseVoltage.1.1.2 = 1172 Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpPduCircuitTotalCurrent'] tlpPduCircuitTotalCurrent = No Such Instance currently exists at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlpPduCircuitTotalCurrent = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlpAtsOutputCurrent'] tlpAtsOutputCurrent = No Such Instance currently exists at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlpAtsOutputCurrent = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlEnvHumidity'] tlEnvHumidity = No Such Object available on this agent at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlEnvHumidity = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlEnvTemperatureC'] tlEnvTemperatureC = No Such Object available on this agent at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlEnvTemperatureC = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'TRIPPLITE-MIB:TRIPPLITE-PRODUCTS:TRIPPLITE-12X' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'tlUpsBatteryAge'] tlUpsBatteryAge = No Such Object available on this agent at this OID Expected DESCRIPTION (Corrected spelling errors): At line 45 in /opt/librenms/mibs/poweralert/TRIPPLITE-12X Invalid snmp_walk() data = tlUpsBatteryAge = No Such Object available on this agent at this OID Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/sensors/cisco-entity-sensor.inc.php on line 5 ENTITY-SENSOR: Caching OIDs: entPhysicalDescr SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'entPhysicalDescr'] entPhysicalDescr = No Such Object available on this agent at this OID Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",23,"ipmi"] 2.32ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",23,"ipmi"] 0.99ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",23,"ipmi"] 0.94ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",23,"ipmi"] 0.93ms] Airflow: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",23,"snmp"] 0.95ms] Current: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryCurrent.0'] No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputCurrent'] upsOutputCurrent = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputCurrent'] upsInputCurrent = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassCurrent'] upsBypassCurrent = No Such Instance currently exists at this OID Dynamic Discovery (current): array ( 'data' => array ( 0 => array ( 'oid' => 'tlpPduCircuitTotalCurrent', 'num_oid' => '.1.3.6.1.4.1.850.1.1.3.2.3.4.1.1.4.{{ $index }}', 'index' => 'tlpPduCircuitTotalCurrent.{{ $index }}', 'divisor' => 100, 'descr' => 'Current', ), 1 => array ( 'oid' => 'tlpAtsOutputCurrent', 'num_oid' => '.1.3.6.1.4.1.850.1.1.3.4.3.2.1.1.5.1.{{ $index }}', 'descr' => 'Current', 'divisor' => 100, ), ), ) Data tlpPduCircuitTotalCurrent: array ( ) Data tlpAtsOutputCurrent: array ( ) array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",23,"snmp"] 1.45ms] Charge: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OvqU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsEstimatedChargeRemaining.0'] No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",23,"snmp"] 1.43ms] Dbm: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",23,"snmp"] 1.02ms] Fanspeed: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",23,"snmp"] 0.97ms] Frequency: RFC1628 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputFrequency'] upsInputFrequency = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputFrequency.0'] No Such Instance currently exists at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassFrequency.0'] No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",23,"snmp"] 1.37ms] Humidity: Dynamic Discovery (humidity): array ( 'data' => array ( 0 => array ( 'oid' => 'tlEnvHumidity', 'num_oid' => '.1.3.6.1.4.1.850.101.1.2.1.{{ $index }}', 'descr' => 'Ambient Humidity', 'divisor' => 10, 'multiplier' => 10, 'low_limit' => 10, 'high_limit' => 90, 'group' => 'EnviroSense', 'skip_values' => array ( 0 => array ( 'oid' => 'tlEnvHumidity', 'op' => 'exists', 'value' => false, ), ), ), ), ) Data tlEnvHumidity: array ( ) array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",23,"snmp"] 1.29ms] Load: RFC1628 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputPercentLoad'] upsOutputPercentLoad = No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",23,"snmp"] 1.39ms] Loss: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["loss",23,"snmp"] 1.02ms] Power: RFC1628 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputPower'] upsOutputPower = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputTruePower'] upsInputTruePower = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassPower'] upsBypassPower = No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",23,"snmp"] 1.59ms] Power_consumed: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",23,"snmp"] 1.13ms] Power_factor: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",23,"snmp"] 1.15ms] Runtime: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.2.2.0'] No Such Instance currently exists at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.33.1.2.3.0'] No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",23,"snmp"] 1.47ms] Signal: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",23,"snmp"] 1ms] State: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqe' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryStatus.0'] No Such Instance currently exists at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqe' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputSource.0'] No Such Instance currently exists at this OID array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",23,"snmp"] 1.37ms] Count: Dynamic Discovery (count): array ( 'data' => array ( 0 => array ( 'oid' => 'tlUpsBatteryAge', 'num_oid' => '.1.3.6.1.4.1.850.100.1.2.1.{{ $index }}', 'descr' => 'Battery Age (Years)', ), ), ) Data tlUpsBatteryAge: array ( ) array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",23,"snmp"] 0.98ms] Temperature: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryTemperature.0'] No Such Instance currently exists at this OID Dynamic Discovery (temperature): array ( 'data' => array ( 0 => array ( 'oid' => 'tlEnvTemperatureC', 'num_oid' => '.1.3.6.1.4.1.850.101.1.1.1.{{ $index }}', 'descr' => 'Ambient Temperature', 'divisor' => 10, 'multiplier' => 10, 'low_limit' => 0, 'high_limit' => 40, 'group' => 'EnviroSense', 'skip_values' => array ( 0 => array ( 'oid' => 'tlEnvTemperatureC', 'op' => 'exists', 'value' => false, ), ), ), ), ) Data tlEnvTemperatureC: array ( ) array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",23,"snmp"] 1.45ms] Tv_signal: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["tv_signal",23,"snmp"] 1.19ms] Bitrate: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["bitrate",23,"snmp"] 1.08ms] Voltage: RFC1628 SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OqvU' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBatteryVoltage.0'] No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsOutputVoltage'] upsOutputVoltage = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsInputVoltage'] upsInputVoltage = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'UPS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'upsBypassVoltage'] upsBypassVoltage = No Such Instance currently exists at this OID Dynamic Discovery (voltage): array ( 'data' => array ( 0 => array ( 'oid' => 'tlpPduInputPhaseVoltage', 'num_oid' => '.1.3.6.1.4.1.850.1.1.3.2.3.1.2.1.4.{{ $index }}', 'descr' => 'Input', 'divisor' => 10, 'multiplier' => 1, 'low_limit' => 110, 'high_limit' => 240, ), 1 => array ( 'oid' => 'tlpAtsInputPhaseVoltage', 'num_oid' => '.1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.{{ $index }}', 'descr' => 'Input', 'divisor' => 10, 'multiplier' => 1, 'low_limit' => 110, 'high_limit' => 240, ), ), ) Data tlpPduInputPhaseVoltage: array ( ) Data tlpAtsInputPhaseVoltage: array ( '1.1.1' => array ( 'tlpAtsInputPhaseVoltage' => '1160', ), '1.1.2' => array ( 'tlpAtsInputPhaseVoltage' => '1172', ), ) Sensor fetched value: 1160 Cur 116, Low: 110, Low Warn: null, Warn: null, High: 240 Discover sensor: .1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.1.1.1, 1.1.1, poweralert, Input, snmp, 10, 1, , 116, (limits: LL: 110, LW: , W: , H: 240) SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",23,"poweralert","1.1.1"] 1.25ms] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",23,"poweralert","1.1.1"] 0.84ms] . Sensor fetched value: 1172 Cur 117.2, Low: 110, Low Warn: null, Warn: null, High: 240 Discover sensor: .1.3.6.1.4.1.850.1.1.3.4.3.1.2.1.5.1.1.1.1.2, 1.1.2, poweralert, Input, snmp, 10, 1, , 117.2, (limits: LL: 110, LW: , W: , H: 240) SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",23,"poweralert","1.1.2"] 0.77ms] SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",23,"poweralert","1.1.2"] 0.84ms] . array ( 'poweralert' => array ( '1.1.1' => 1, '1.1.2' => 1, ), ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",23,"snmp"] 1.09ms] 1.1.1 -> poweralert 1.1.2 -> poweralert Snr: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",23,"snmp"] 1.02ms] Pressure: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",23,"snmp"] 1.01ms] Cooling: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",23,"snmp"] 0.94ms] Delay: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",23,"snmp"] 0.94ms] Quality_factor: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",23,"snmp"] 0.97ms] Chromatic_dispersion: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",23,"snmp"] 0.93ms] Ber: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",23,"snmp"] 0.95ms] Eer: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",23,"snmp"] 0.98ms] Waterflow: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",23,"snmp"] 0.94ms] Percent: array ( ) SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["percent",23,"snmp"] 0.93ms] >> Runtime for discovery module 'sensors': 1.3470 seconds with 8168 bytes >> SNMP: [19/0.75s] MySQL: [38/0.43s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'aixFsTableEntry'] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (IBM-AIX-MIB): At line 65 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (IBM-AIX-MIB): At line 65 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) aix_filesystem : SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'] fileSystemSpaceTable = No Such Object available on this agent at this OID Invalid snmp_walk() data = fileSystemSpaceTable = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'datasetTable'] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (FREENAS-MIB): At line 65 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (FREENAS-MIB): At line 65 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '23' AND `storage_type` != 'dataset' [] 1.04ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'zpoolTable'] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (FREENAS-MIB): At line 65 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (FREENAS-MIB): At line 65 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '23' AND `storage_type` != 'zpool' [] 0.97ms] Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/storage/hpe-ilo.inc.php on line 3 hrStorage : SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dskTable'] dskTable = No Such Object available on this agent at this OID Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '23' AND `storage_type` != 'dsk' [] 0.89ms] Warning: Undefined variable $valid_storage in /opt/librenms/includes/discovery/storage.inc.php on line 10 SQL[SELECT * FROM `storage` WHERE `device_id` = '23' [] 0.62ms] >> Runtime for discovery module 'storage': 0.1410 seconds with 1920 bytes >> SNMP: [5/0.13s] MySQL: [4/0.04s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### Warning: Undefined variable $hrDevices in /opt/librenms/includes/discovery/hr-device.inc.php on line 7 SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrDeviceEntry'] hrDeviceEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrDeviceEntry = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'hrProcessorEntry'] hrProcessorEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrProcessorEntry = No Such Object available on this agent at this OID array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '23' [] 1.08ms] >> Runtime for discovery module 'hr-device': 0.1130 seconds with 0 bytes >> SNMP: [2/0.11s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'cdpCache'] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (CISCO-CDP-MIB): At line 65 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert Cannot find module (CISCO-CDP-MIB): At line 65 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) LLDP-MIB: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'lldpRemTable'] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [23] 1.13ms] SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [23] 1.07ms] SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 0.62ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.0640 seconds with 48 bytes >> SNMP: [0/0.00s] MySQL: [3/0.03s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress'] IP-MIB::ipNetToPhysicalPhysAddress = No Such Instance currently exists at this OID SNMP['/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress'] IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:be:66:59 IP-MIB::ipNetToMediaPhysAddress[2][*] = 68:5:ca:ae:38:2d IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:79:2d:2a IP-MIB::ipNetToMediaPhysAddress[2][*] = 0:c:29:e0:8d:6a IP-MIB::ipNetToMediaPhysAddress[2][*] = f0:9f:c2:1a:5b:8f SQL[SELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [23,""] 1.16ms] SQL[SELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [23,2] 0.91ms] Warning: Undefined array key "IP-MIB::ipNetToPhysicalPhysAddress" in /opt/librenms/includes/discovery/arp-table.inc.php on line 50 eth0: 0:c:29:be:66:59 => 10.0.0.5 68:5:ca:ae:38:2d => 10.0.0.86 0:c:29:79:2d:2a => 10.0.0.120 0:c:29:e0:8d:6a => 10.0.0.221 f0:9f:c2:1a:5b:8f => 10.0.0.254 SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [] 1.31ms] >> Runtime for discovery module 'arp-table': 0.0950 seconds with 13648 bytes >> SNMP: [2/0.09s] MySQL: [3/0.03s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP['/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'bgpLocalAs'] "15.5.5 (Build 1069)" No BGP on host Warning: Undefined variable $peers_data in /opt/librenms/includes/discovery/bgp-peers.inc.php on line 55 Warning: Undefined variable $peer2 in /opt/librenms/includes/discovery/bgp-peers.inc.php on line 55 Peers : Warning: Undefined array key 1 in /opt/librenms/includes/discovery/functions.inc.php on line 1026 SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [23,""] 0.78ms] SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [23,""] 0.52ms] SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [23] 0.65ms] >> Runtime for discovery module 'bgp-peers': 0.0250 seconds with 632 bytes >> SNMP: [1/0.02s] MySQL: [3/0.02s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = ? [23] 0.65ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'] No Such Object available on this agent at this OID Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/vlans/cisco-vtp.inc.php on line 3 >> Runtime for discovery module 'vlans': 0.0860 seconds with 272 bytes >> SNMP: [2/0.08s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ printer-supplies ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'diskIOEntry'] diskIOEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '23' [] 0.96ms] >> Runtime for discovery module 'ucd-diskio': 0.0290 seconds with 160 bytes >> SNMP: [1/0.03s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 80 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### Instances: SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0'] BRIDGE-MIB::dot1dStpProtocolSpecification.0 = No Such Object available on this agent at this OID SQL[select * from `stp` where `stp`.`device_id` = ? and `stp`.`device_id` is not null [23] 1.09ms] Ports: SQL[select * from `ports_stp` where `ports_stp`.`device_id` = ? and `ports_stp`.`device_id` is not null [23] 0.68ms] >> Runtime for discovery module 'stp': 0.0460 seconds with 61872 bytes >> SNMP: [1/0.04s] MySQL: [2/0.02s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### Warning: Undefined array key "os_group" in /opt/librenms/includes/discovery/ntp.inc.php on line 30 >> Runtime for discovery module 'ntp': 0.0000 seconds with 80 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. Modules status: Global+ OS Device #### Load disco module wireless #### SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ap-count"] 0.85ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"clients"] 0.77ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"quality"] 0.78ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"capacity"] 0.72ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"utilization"] 0.74ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rate"] 0.72ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ccq"] 0.76ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"snr"] 0.72ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"sinr"] 0.71ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rsrp"] 0.73ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rsrq"] 0.71ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"ssr"] 0.7ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"mse"] 0.71ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"xpi"] 0.75ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"rssi"] 0.72ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"power"] 0.76ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"noise-floor"] 0.76ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"errors"] 0.73ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"error-ratio"] 0.72ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"error-rate"] 1.58ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"frequency"] 0.74ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"distance"] 0.73ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"cell"] 0.75ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [23,"channel"] 0.7ms] >> Runtime for discovery module 'wireless': 0.0310 seconds with 10600 bytes >> SNMP: [0/0.00s] MySQL: [24/0.19s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS Device #### Load disco module fdb-table #### SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [23] 0.6ms] SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = ? [23] 0.62ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/poweralert' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.1220 seconds with 144 bytes >> SNMP: [0/0.00s] MySQL: [2/0.01s] RRD: [0/0.00s] #### Unload disco module fdb-table #### Modules status: Global+ OS Device #### Load disco module mpls #### >> Runtime for discovery module 'mpls': 0.0000 seconds with 488 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mpls #### SQL[UPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [4.217,23] 1.2ms] Discovered in 4.217 seconds /opt/librenms/discovery.php 10.0.0.251 2022-09-12 14:55:09 - 1 devices discovered in 4.559 secs SNMP [58/2.14s]: Snmpget[29/0.94s] Snmpwalk[28/1.18s] Snmpgetnext[1/0.02s] SQL [118/1.78s]: Select[106/1.69s] Update[7/0.05s] Delete[5/0.04s] RRD [0/0.00s]: