- SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.0.3.193' ORDER BY device_id DESC [0;33m[][0m 0.95ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[22][0m 0.45ms]
- 10.0.3.193 22 apc [FPING] /usr/sbin/fping -e -q -c 3 -p 500 -t 500 10.0.3.193
- Array
- (
- [xmt] => 3
- [rcv] => 3
- [loss] => 0
- [min] => 0.80
- [max] => 139
- [avg] => 47.3
- [exitcode] => 0
- )
- SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.80","max":"139","avg":"47.3","device_id":22}[0m 2.47ms]
- SNMP Check response code: 0
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"poll_mib"][0m 1.32ms]
- Attempting to initialize OS: apc
- OS initilized as Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
- .*.*.0 = RMON-G-04
- .*.*.0 = .*.4.1.3*.5
- .*.*.0 = APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016)
- >> Runtime for discovery module 'core': 0.0410 seconds with 1184 bytes
- >> SNMP: [2/0.10s] MySQL: [4/0.01s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
- APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016)
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
- .*.4.1.3*.5
- | APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016) | .1.3.6.1.4.1.318.1.3.8.5 |
- OS: APC Management Module (apc)
- >> Runtime for discovery module 'os': 0.1030 seconds with 1336 bytes
- >> SNMP: [2/0.10s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifDescr[0m]
- ifDescr.1 = LOOPBACK
- ifDescr.2 = vmac0
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifName[0m]
- ifName = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifAlias[0m]
- ifAlias = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifType[0m]
- ifType.1 = softwareLoopback
- ifType.2 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => LOOPBACK
- [ifType] => softwareLoopback
- )
- [2] => Array
- (
- [ifDescr] => vmac0
- [ifType] => ethernetCsmacd
- )
- )
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[22][0m 1.41ms]
- ..
- >> Runtime for discovery module 'ports': 0.6100 seconds with 4136 bytes
- >> SNMP: [4/0.61s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '22' [0;33m[][0m 0.83ms]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifStackStatus[0m]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.1330 seconds with 1784 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 entPhysicalEntry[0m]
- entPhysicalEntry = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[22][0m 1.02ms]
- >> Runtime for discovery module 'entity-physical': 0.1620 seconds with 5504 bytes
- >> SNMP: [1/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global- OS- Device Module [ entity-state ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrProcessorLoad[0m]
- hrProcessorLoad = No Such Object available on this agent at this OID
- UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[22][0m 1.49ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[22][0m 0.66ms]
- SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[22][0m 0.61ms]
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m]
- No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[22][0m 0.89ms]
- SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.62ms]
- >> Runtime for discovery module 'processors': 0.2030 seconds with 139592 bytes
- >> SNMP: [2/0.19s] MySQL: [5/0.01s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[22][0m 2.21ms]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '22' [0;33m[][0m 1.1ms]
- >> Runtime for discovery module 'mempools': 0.4260 seconds with 28648 bytes
- >> SNMP: [3/0.41s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[22][0m 0.6ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2664 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
- Modules status: Global- OS- Device Module [ vrf ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntIfIndex[0m]
- ipAdEntIfIndex.* 2
- ipAdEntIfIndex.* 1
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntNetMask.10.0.3.193[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[22,"2"][0m 0.72ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,"2"][0m 0.5ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.3.193\/20"][0m 0.51ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.0.3.193\/20"][0m 0.48ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.3.193\/20"][0m 0.53ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["10.0.3.193",20,120][0m 0.54ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.0.3.193",20,120][0m 0.46ms]
- .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[22,"1"][0m 1.28ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,"1"][0m 0.61ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/32"][0m 0.34ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"127.0.0.1\/32"][0m 0.33ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/32"][0m 0.3ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["127.0.0.1",32,119][0m 0.35ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"127.0.0.1",32,119][0m 0.28ms]
- .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[22][0m 0.55ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.1930 seconds with 34424 bytes
- >> SNMP: [3/0.18s] MySQL: [5/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
- ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[22][0m 0.87ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.2300 seconds with 3376 bytes
- >> SNMP: [2/0.23s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS- Device Module [ route ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- Pre-cache apc: coolingUnitStatusAnalogEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitStatusAnalogEntry[0m]
- coolingUnitStatusAnalogEntry = No Such Object available on this agent at this OID
- upsPhaseNumInputPhases SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsPhaseNumInputPhases.1[0m]
- No Such Object available on this agent at this OID
- memSensorsStatusTable SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUse -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 memSensorsStatusTable[0m]
- memSensorsStatusModuleNumber.0.1 = 0
- memSensorsStatusSensorNumber.0.1 = 1
- memSensorsStatusSensorName.0.1 = "R/G4"
- memSensorsStatusSensorLocation.0.1 = "Front of Rack"
- memSensorsTemperature.0.1 = 22
- memSensorsHumidity.0.1 = 51
- memSensorsCommStatus.0.1 = 2
- memSensorsAlarmStatus.0.1 = 1
- memSensorsStatusSysTempUnits SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 memSensorsStatusSysTempUnits.0[0m]
- celsius
- Array
- (
- [cooling_unit_analog] => Array
- (
- )
- [apcups_phase_count] =>
- [mem_sensors_status] => Array
- (
- [0.1] => Array
- (
- [memSensorsStatusModuleNumber] => 0
- [memSensorsStatusSensorNumber] => 1
- [memSensorsStatusSensorName] => R/G4
- [memSensorsStatusSensorLocation] => Front of Rack
- [memSensorsTemperature] => 22
- [memSensorsHumidity] => 51
- [memSensorsCommStatus] => 2
- [memSensorsAlarmStatus] => 1
- )
- )
- [memSensorsStatusSysTempUnits] => celsius
- )
- Caching data: sensors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsRackInletHighTempMetric[0m]
- airIRG2RDT2ThresholdsRackInletHighTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsSupplyAirHighTempMetric[0m]
- airIRG2RDT2ThresholdsSupplyAirHighTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsReturnAirHighTempMetric[0m]
- airIRG2RDT2ThresholdsReturnAirHighTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsBasicOutputStatus[0m]
- upsBasicOutputStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusOperateMode[0m]
- airIRRP100UnitStatusOperateMode = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusInputState[0m]
- airIRRP100UnitStatusInputState = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusOutputState[0m]
- airIRRP100UnitStatusOutputState = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusOperateMode[0m]
- airIRRP500UnitStatusOperateMode = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusInputState[0m]
- airIRRP500UnitStatusInputState = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusOutputState[0m]
- airIRRP500UnitStatusOutputState = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2PhaseStatusTable[0m]
- rPDU2PhaseStatusTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2DeviceStatusTable[0m]
- rPDU2DeviceStatusTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2SensorTempHumidityStatusTable[0m]
- rPDU2SensorTempHumidityStatusTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSourceAStatus[0m]
- atsStatusSourceAStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSourceBStatus[0m]
- atsStatusSourceBStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSwitchStatus[0m]
- atsStatusSwitchStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSelectedSource[0m]
- atsStatusSelectedSource = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusRedundancyState[0m]
- atsStatusRedundancyState = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusPhaseSyncStatus[0m]
- atsStatusPhaseSyncStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTempMetric[0m]
- airIRRP100UnitStatusRackInletTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusSupplyAirTempMetric[0m]
- airIRRP100UnitStatusSupplyAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusReturnAirTempMetric[0m]
- airIRRP100UnitStatusReturnAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature1Metric[0m]
- airIRRP100UnitStatusRackInletTemperature1Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature2Metric[0m]
- airIRRP100UnitStatusRackInletTemperature2Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature3Metric[0m]
- airIRRP100UnitStatusRackInletTemperature3Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric[0m]
- airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveControlCardTempMetric[0m]
- airIRRP100UnitStatusCompressorDriveControlCardTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusSupplyAirTempMetric[0m]
- airIRRP500UnitStatusSupplyAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusReturnAirTempMetric[0m]
- airIRRP500UnitStatusReturnAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature1Metric[0m]
- airIRRP500UnitStatusRackInletTemperature1Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature2Metric[0m]
- airIRRP500UnitStatusRackInletTemperature2Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature3Metric[0m]
- airIRRP500UnitStatusRackInletTemperature3Metric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusRackInletTempMetric[0m]
- airIRG2RDT2StatusRackInletTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSupplyAirTempMetric[0m]
- airIRG2RDT2StatusSupplyAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusReturnAirTempMetric[0m]
- airIRG2RDT2StatusReturnAirTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSuctionTempMetric[0m]
- airIRG2RDT2StatusSuctionTempMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusSupplyHumidity[0m]
- airIRRP100UnitStatusSupplyHumidity = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusReturnHumidity[0m]
- airIRRP100UnitStatusReturnHumidity = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusSupplyHumidity[0m]
- airIRRP500UnitStatusSupplyHumidity = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusReturnHumidity[0m]
- airIRRP500UnitStatusReturnHumidity = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusAirFlowMetric[0m]
- airIRRP100UnitStatusAirFlowMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusAirFlowMetric[0m]
- airIRRP500UnitStatusAirFlowMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusAirFlowMetric[0m]
- airIRG2RDT2StatusAirFlowMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveVoltage[0m]
- airIRRP100UnitStatusCompressorDriveVoltage = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveDCLinkVoltage[0m]
- airIRRP100UnitStatusCompressorDriveDCLinkVoltage = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusHumidifierCurrent[0m]
- airIRRP100UnitStatusHumidifierCurrent = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveCurrent[0m]
- airIRRP100UnitStatusCompressorDriveCurrent = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusHumidifierCurrent[0m]
- airIRRP500UnitStatusHumidifierCurrent = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusFanSpeed[0m]
- airIRRP100UnitStatusFanSpeed = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusFanSpeed[0m]
- airIRRP500UnitStatusFanSpeed = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveSpeed[0m]
- airIRRP100UnitStatusCompressorDriveSpeed = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDrivePower[0m]
- airIRRP100UnitStatusCompressorDrivePower = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCoolDemand[0m]
- airIRRP100UnitStatusCoolDemand = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCoolOutput[0m]
- airIRRP100UnitStatusCoolOutput = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusCoolDemand[0m]
- airIRRP500UnitStatusCoolDemand = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusCoolOutput[0m]
- airIRRP500UnitStatusCoolOutput = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSuctionPressureMetric[0m]
- airIRG2RDT2StatusSuctionPressureMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusDischargePressureMetric[0m]
- airIRG2RDT2StatusDischargePressureMetric = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusCoolOutput[0m]
- airIRG2RDT2StatusCoolOutput = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusCoolDemand[0m]
- airIRG2RDT2StatusCoolDemand = No Such Object available on this agent at this OID
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 entPhysicalDescr[0m]
- entPhysicalDescr = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"ipmi_hostname"][0m 0.52ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",22,"ipmi"][0m 0.7ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",22,"ipmi"][0m 0.67ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",22,"ipmi"][0m 0.55ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",22,"ipmi"][0m 0.56ms]
- Airflow: Dynamic Discovery (airflow): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusAirFlowMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11.
- [index] => airIRRP100UnitStatusAirFlowMetric.{{ $index }}
- [descr] => Air Flow
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP500UnitStatusAirFlowMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11.
- [index] => airIRRP500UnitStatusAirFlowMetric.{{ $index }}
- [descr] => Air Flow
- [divisor] => 10
- )
- [2] => Array
- (
- [oid] => airIRG2RDT2StatusAirFlowMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.5.
- [index] => airIRG2RDT2StatusAirFlowMetric.{{ $index }}
- [descr] => Air Flow
- )
- )
- )
- Data airIRRP100UnitStatusAirFlowMetric: Array
- (
- )
- Data airIRRP500UnitStatusAirFlowMetric: Array
- (
- )
- Data airIRG2RDT2StatusAirFlowMetric: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",22,"snmp"][0m 0.57ms]
- Current: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDUStatusPhaseIndex[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDULoadPhaseConfigIndex[0m]
- .*.4.1.3*.*.1 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDULoadDevNumBanks.0[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -t 30 -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.26.9.4.3.1.1[0m]
- .*.4.1.3*.*.1 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsConfigPhaseTableIndex[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsHighPrecOutputCurrent[0m]
- upsHighPrecOutputCurrent = No Such Object available on this agent at this OID
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/current/apc.inc.php on line 202
- Dynamic Discovery (current): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusHumidifierCurrent
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33.
- [index] => airIRRP100UnitStatusHumidifierCurrent.{{ $index }}
- [descr] => Humidifier
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveCurrent
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38.
- [index] => airIRRP100UnitStatusCompressorDriveCurrent.{{ $index }}
- [descr] => Compressor Drive
- [divisor] => 10
- )
- [2] => Array
- (
- [oid] => airIRRP500UnitStatusHumidifierCurrent
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33.
- [index] => airIRRP100UnitStatusHumidifierCurrent.{{ $index }}
- [descr] => Humidifier
- [divisor] => 10
- )
- )
- )
- Data airIRRP100UnitStatusHumidifierCurrent: Array
- (
- )
- Data airIRRP100UnitStatusCompressorDriveCurrent: Array
- (
- )
- Data airIRRP500UnitStatusHumidifierCurrent: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",22,"snmp"][0m 1.07ms]
- Charge: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.3.1.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.1.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",22,"snmp"][0m 1.09ms]
- Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",22,"snmp"][0m 0.77ms]
- Fanspeed:
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/fanspeed/apc.inc.php on line 26
- Dynamic Discovery (fanspeed): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusFanSpeed
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12.
- [index] => airIRRP100UnitStatusFanSpeed.{{ $index }}
- [descr] => Fan Speed (%)
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP500UnitStatusFanSpeed
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12.
- [index] => airIRRP500UnitStatusFanSpeed.{{ $index }}
- [descr] => Fan Speed (%)
- [divisor] => 10
- )
- )
- )
- Data airIRRP100UnitStatusFanSpeed: Array
- (
- )
- Data airIRRP500UnitStatusFanSpeed: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",22,"snmp"][0m 0.81ms]
- Frequency: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.3.2.1.4[0m]
- .*.4.1.3*.*.4 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.4.2.1.4[0m]
- .*.4.1.3*.*.4 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.3.2.4.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.4.2.2.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- Dynamic Discovery (frequency): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveSpeed
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35.
- [index] => airIRRP100UnitStatusCompressorDriveSpeed.{{ $index }}
- [descr] => Drive Speed
- [divisor] => 10
- )
- )
- )
- Data airIRRP100UnitStatusCompressorDriveSpeed: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",22,"snmp"][0m 1.34ms]
- Humidity: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemConfigProbesTable[0m]
- iemConfigProbesTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemStatusProbesTable[0m]
- iemStatusProbesTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsProbeStatus[0m]
- emsProbeStatusProbeIndex.1 = 1
- emsProbeStatusProbeName.1 = "R/G4"
- emsProbeStatusProbeTemperature.1 = 22
- emsProbeStatusProbeHighTempThresh.1 = 27
- emsProbeStatusProbeLowTempThresh.1 = 18
- emsProbeStatusProbeHumidity.1 = 51
- emsProbeStatusProbeHighHumidityThresh.1 = 70
- emsProbeStatusProbeLowHumidityThresh.1 = 30
- emsProbeStatusProbeSerialNumber.1 = "L1"
- emsProbeStatusProbeCommStatus.1 = commsEstablished
- emsProbeStatusProbeAlarmStatus.1 = 0
- emsProbeStatusProbeMaxTempThresh.1 = 32
- emsProbeStatusProbeMinTempThresh.1 = 15
- emsProbeStatusProbeMaxHumidityThresh.1 = 80
- emsProbeStatusProbeMinHumidityThresh.1 = 20
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.13.1.1.6.1, 1, apc, R/G4, snmp, 1, 1, , 51
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","humidity",22,"apc","1"][0m 15.25ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["humidity",22,"apc","1"][0m 0.84ms]
- .Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.6.0.1, memSensorsHumidity.0.1, apc, R/G4 - Front of Rack, snmp, 1, 1, , 51
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","humidity",22,"apc","memSensorsHumidity.0.1"][0m 0.72ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["humidity",22,"apc","memSensorsHumidity.0.1"][0m 0.75ms]
- .Dynamic Discovery (humidity): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusSupplyHumidity
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8.
- [index] => airIRRP100UnitStatusSupplyHumidity.{{ $index }}
- [descr] => Supply
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusReturnHumidity
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8.
- [index] => airIRRP100UnitStatusReturnHumidity.{{ $index }}
- [descr] => Return
- [divisor] => 10
- )
- [2] => Array
- (
- [oid] => airIRRP500UnitStatusSupplyHumidity
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8.
- [index] => airIRRP500UnitStatusSupplyHumidity.{{ $index }}
- [descr] => Supply
- [divisor] => 10
- )
- [3] => Array
- (
- [oid] => airIRRP500UnitStatusReturnHumidity
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8.
- [index] => airIRRP500UnitStatusSupplyHumidity.{{ $index }}
- [descr] => Return
- [divisor] => 10
- )
- [4] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusTable
- [value] => rPDU2SensorTempHumidityStatusRelativeHumidity
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.10.
- [index] => rPDU2SensorTempHumidityStatusRelativeHumidity.{{ $index }}
- [descr] => Humidity Probe
- [skip_values] => Array
- (
- [0] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusType
- [op] => =
- [value] => 4
- )
- [1] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusRelativeHumidity
- [op] => <
- [value] => 0
- )
- )
- )
- )
- )
- Data airIRRP100UnitStatusSupplyHumidity: Array
- (
- )
- Data airIRRP100UnitStatusReturnHumidity: Array
- (
- )
- Data airIRRP500UnitStatusSupplyHumidity: Array
- (
- )
- Data airIRRP500UnitStatusReturnHumidity: Array
- (
- )
- Data rPDU2SensorTempHumidityStatusTable: Array
- (
- )
- Array
- (
- [apc] => Array
- (
- [1] => 1
- [memSensorsHumidity.0.1] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",22,"snmp"][0m 1.15ms]
- 1 -> apc
- memSensorsHumidity.0.1 -> apc
- Load: APC Load SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m +PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsHighPrecOutputLoad.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m +PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsAdvOutputLoad.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",22,"snmp"][0m 1.81ms]
- Power:
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/power/apc.inc.php on line 26
- Dynamic Discovery (power): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDrivePower
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35.
- [index] => airIRRP100UnitStatusCompressorDrivePower.{{ $index }}
- [descr] => Drive Power
- [multiplier] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusCoolDemand
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13.
- [index] => airIRRP100UnitStatusCoolDemand.{{ $index }}
- [descr] => Cooling Demand
- [multiplier] => 100
- )
- [2] => Array
- (
- [oid] => airIRRP100UnitStatusCoolOutput
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14.
- [index] => airIRRP100UnitStatusCoolOutput.{{ $index }}
- [descr] => Cooling Output
- [multiplier] => 100
- )
- [3] => Array
- (
- [oid] => airIRRP500UnitStatusCoolDemand
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13.
- [index] => airIRRP500UnitStatusCoolDemand.{{ $index }}
- [descr] => Cooling Demand
- [multiplier] => 100
- )
- [4] => Array
- (
- [oid] => airIRRP500UnitStatusCoolOutput
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14.
- [index] => airIRRP500UnitStatusCoolOutput.{{ $index }}
- [descr] => Cooling Output
- [multiplier] => 100
- )
- [5] => Array
- (
- [oid] => rPDU2DeviceStatusTable
- [value] => rPDU2DeviceStatusPower
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.5.
- [multiplier] => 10
- [index] => rPDU2DeviceStatusPower.{{ $index }}
- [descr] => Power, Total
- )
- )
- )
- Data airIRRP100UnitStatusCompressorDrivePower: Array
- (
- )
- Data airIRRP100UnitStatusCoolDemand: Array
- (
- )
- Data airIRRP100UnitStatusCoolOutput: Array
- (
- )
- Data airIRRP500UnitStatusCoolDemand: Array
- (
- )
- Data airIRRP500UnitStatusCoolOutput: Array
- (
- )
- Data rPDU2DeviceStatusTable: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",22,"snmp"][0m 0.77ms]
- Runtime: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnUt -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.3.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100GroupSetpointsCoolMetric.0[0m]
- .*.4.1.3*.*.2.2.0 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",22,"snmp"][0m 1.1ms]
- Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",22,"snmp"][0m 0.65ms]
- State: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsAdvBatteryReplaceIndicator.0[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitStatusDiscreteEntry[0m]
- coolingUnitStatusDiscreteEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitExtendedDiscreteEntry[0m]
- coolingUnitExtendedDiscreteEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsOutputRelayControlEntry[0m]
- emsOutputRelayControlOutputRelayIndex.1 = 1
- emsOutputRelayControlOutputRelayName.1 = "Relay"
- emsOutputRelayControlOutputRelayCommand.1 = immediateOpenEMS
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["Relay"][0m 0.78ms]
- SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[1][0m 0.8ms]
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1, .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1, Relay, Relay, snmp, 1, 1, , 2
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.97ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.89ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.67ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["Relay"][0m 0.48ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":227,"state_index_id":1}[0m 2.19ms]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsOutletControlEntry[0m]
- emsOutletControlOutletIndex.1 = 1
- emsOutletControlOutletName.1 = "Outlet"
- emsOutletControlOutletCommand.1 = immediateOffEMS
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["Outlet"][0m 1.41ms]
- SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[2][0m 1.62ms]
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1, .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1, Outlet, Outlet, snmp, 1, 1, , 2
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 0.98ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 2.89ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 0.73ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["Outlet"][0m 0.49ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":228,"state_index_id":2}[0m 2.21ms]
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["memSensorsCommStatus"][0m 0.57ms]
- SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[3][0m 0.66ms]
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.7.0.1, memSensorsCommStatus.0.1, memSensorsCommStatus, memSensorsCommStatus, snmp, 1, 1, , 2
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.82ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.94ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.77ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["memSensorsCommStatus"][0m 0.53ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":229,"state_index_id":3}[0m 2.06ms]
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["memSensorsAlarmStatus"][0m 0.54ms]
- SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[4][0m 0.64ms]
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.8.0.1, memSensorsAlarmStatus.0.1, memSensorsAlarmStatus, memSensorsAlarmStatus, snmp, 1, 1, , 1
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.79ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.98ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.79ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["memSensorsAlarmStatus"][0m 0.52ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":230,"state_index_id":4}[0m 2.35ms]
- Dynamic Discovery (state): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => upsBasicOutputStatus
- [value] => upsBasicOutputStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.1.4.1.1.
- [descr] => Output Status
- [index] => {{ $index }}
- [state_name] => upsBasicOutputStatus
- [states] => Array
- (
- [0] => Array
- (
- [descr] => unknown
- [graph] => 0
- [value] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [descr] => onLine
- [graph] => 0
- [value] => 2
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => onBattery
- [graph] => 0
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => onSmartBoost
- [graph] => 0
- [value] => 4
- [generic] => 0
- )
- [4] => Array
- (
- [descr] => timedSleeping
- [graph] => 0
- [value] => 5
- [generic] => 0
- )
- [5] => Array
- (
- [descr] => softwareBypass
- [graph] => 0
- [value] => 6
- [generic] => 1
- )
- [6] => Array
- (
- [descr] => off
- [graph] => 0
- [value] => 7
- [generic] => 2
- )
- [7] => Array
- (
- [descr] => rebooting
- [graph] => 0
- [value] => 8
- [generic] => 1
- )
- [8] => Array
- (
- [descr] => switchedBypass
- [graph] => 0
- [value] => 9
- [generic] => 1
- )
- [9] => Array
- (
- [descr] => hardwareFailureBypass
- [graph] => 0
- [value] => 10
- [generic] => 2
- )
- [10] => Array
- (
- [descr] => sleepingUntilPowerReturn
- [graph] => 0
- [value] => 11
- [generic] => 1
- )
- [11] => Array
- (
- [descr] => onSmartTrim
- [graph] => 0
- [value] => 12
- [generic] => 1
- )
- [12] => Array
- (
- [descr] => ecoMode
- [graph] => 0
- [value] => 13
- [generic] => 0
- )
- [13] => Array
- (
- [descr] => hotStandby
- [graph] => 0
- [value] => 14
- [generic] => 0
- )
- [14] => Array
- (
- [descr] => onBatteryTest
- [graph] => 0
- [value] => 15
- [generic] => 1
- )
- [15] => Array
- (
- [descr] => emergencyStaticBypass
- [graph] => 0
- [value] => 16
- [generic] => 2
- )
- [16] => Array
- (
- [descr] => staticBypassStandby
- [graph] => 0
- [value] => 17
- [generic] => 1
- )
- [17] => Array
- (
- [descr] => powerSavingMode
- [graph] => 0
- [value] => 18
- [generic] => 0
- )
- [18] => Array
- (
- [descr] => spotMode
- [graph] => 0
- [value] => 19
- [generic] => 0
- )
- [19] => Array
- (
- [descr] => eConversion
- [graph] => 0
- [value] => 20
- [generic] => 0
- )
- [20] => Array
- (
- [descr] => chargerSpotmode
- [graph] => 0
- [value] => 21
- [generic] => 0
- )
- [21] => Array
- (
- [descr] => inverterSpotmode
- [graph] => 0
- [value] => 22
- [generic] => 0
- )
- )
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusOperateMode
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1.
- [descr] => Unit Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => standby
- [graph] => 1
- [value] => 1
- [generic] => 1
- )
- [1] => Array
- (
- [descr] => on
- [graph] => 1
- [value] => 2
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => idle
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => prestart
- [graph] => 1
- [value] => 4
- [generic] => 1
- )
- [4] => Array
- (
- [descr] => service
- [graph] => 1
- [value] => 5
- [generic] => 1
- )
- [5] => Array
- (
- [descr] => backup
- [graph] => 1
- [value] => 6
- [generic] => 1
- )
- [6] => Array
- (
- [descr] => assist
- [graph] => 1
- [value] => 7
- [generic] => 1
- )
- )
- )
- [2] => Array
- (
- [oid] => airIRRP100UnitStatusInputState
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21.
- [descr] => Input State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => open
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => closed
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- )
- )
- [3] => Array
- (
- [oid] => airIRRP100UnitStatusOutputState
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22.
- [descr] => Output State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => open
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => closed
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- )
- )
- [4] => Array
- (
- [oid] => airIRRP500UnitStatusOperateMode
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1.
- [descr] => Unit Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => standby
- [graph] => 1
- [value] => 1
- [generic] => 1
- )
- [1] => Array
- (
- [descr] => on
- [graph] => 1
- [value] => 2
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => idle
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => prestart
- [graph] => 1
- [value] => 4
- [generic] => 1
- )
- [4] => Array
- (
- [descr] => backup
- [graph] => 1
- [value] => 5
- [generic] => 1
- )
- [5] => Array
- (
- [descr] => assist
- [graph] => 1
- [value] => 6
- [generic] => 1
- )
- )
- )
- [5] => Array
- (
- [oid] => airIRRP500UnitStatusInputState
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21.
- [descr] => Input State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => open
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => closed
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- )
- )
- [6] => Array
- (
- [oid] => airIRRP500UnitStatusOutputState
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22.
- [descr] => Output State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => open
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => closed
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- )
- )
- [7] => Array
- (
- [oid] => rPDU2PhaseStatusTable
- [state_name] => rPDU2PhaseStatusLoadState
- [value] => rPDU2PhaseStatusLoadState
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.6.3.1.4.
- [index] => rPDU2PhaseStatusLoadState.{{ $index }}
- [descr] => Load State, Phase #{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [descr] => lowLoad
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => normal
- [graph] => 1
- [value] => 2
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => nearOverload
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => overload
- [graph] => 1
- [value] => 4
- [generic] => 2
- )
- )
- )
- [8] => Array
- (
- [oid] => rPDU2DeviceStatusTable
- [state_name] => rPDU2DeviceStatusLoadState
- [value] => rPDU2DeviceStatusLoadState
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.4.
- [index] => rPDU2DeviceStatusLoadState.{{ $index }}
- [descr] => Device State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => lowLoad
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => normal
- [graph] => 1
- [value] => 2
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => nearOverload
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => overload
- [graph] => 1
- [value] => 4
- [generic] => 2
- )
- [4] => Array
- (
- [descr] => notsupported
- [graph] => 1
- [value] => 5
- [generic] => 3
- )
- )
- )
- [9] => Array
- (
- [oid] => rPDU2DeviceStatusTable
- [state_name] => rPDU2DeviceStatusPowerSupplyAlarm
- [value] => rPDU2DeviceStatusPowerSupplyAlarm
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.12.
- [index] => rPDU2DeviceStatusPowerSupplyAlarm.{{ $index }}
- [descr] => Power Supply State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => normal
- [graph] => 1
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => alarm
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- )
- )
- [10] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusTable
- [state_name] => rPDU2SensorTempHumidityStatusTempStatus
- [value] => rPDU2SensorTempHumidityStatusTempStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.9.
- [index] => rPDU2SensorTempHumidityStatusTempStatus.{{ $index }}
- [descr] => Temperature Probe Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => notPresent
- [graph] => 1
- [value] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [descr] => belowMin
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- [2] => Array
- (
- [descr] => belowLow
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => normal
- [graph] => 1
- [value] => 4
- [generic] => 0
- )
- [4] => Array
- (
- [descr] => aboveHigh
- [graph] => 1
- [value] => 5
- [generic] => 1
- )
- [5] => Array
- (
- [descr] => aboveMax
- [graph] => 1
- [value] => 6
- [generic] => 2
- )
- )
- [skip_values] => Array
- (
- [0] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusTempStatus
- [op] => =
- [value] => 1
- )
- )
- )
- [11] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusTable
- [state_name] => rPDU2SensorTempHumidityStatusHumidityStatus
- [value] => rPDU2SensorTempHumidityStatusHumidityStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.11.
- [index] => rPDU2SensorTempHumidityStatusHumidityStatus.{{ $index }}
- [descr] => Humidity Probe Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => notPresent
- [graph] => 1
- [value] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [descr] => belowMin
- [graph] => 1
- [value] => 2
- [generic] => 2
- )
- [2] => Array
- (
- [descr] => belowLow
- [graph] => 1
- [value] => 3
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => normal
- [graph] => 1
- [value] => 4
- [generic] => 0
- )
- [4] => Array
- (
- [descr] => aboveHigh
- [graph] => 1
- [value] => 5
- [generic] => 1
- )
- [5] => Array
- (
- [descr] => aboveMax
- [graph] => 1
- [value] => 6
- [generic] => 2
- )
- )
- [skip_values] => Array
- (
- [0] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusHumidityStatus
- [op] => =
- [value] => 1
- )
- )
- )
- [12] => Array
- (
- [oid] => atsStatusSourceAStatus
- [value] => atsStatusSourceAStatus
- [state_name] => atsStatusSourceAStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.12.
- [index] => atsStatusSourceAStatus.{{ $index }}
- [descr] => Source A Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => Fail
- [graph] => 0
- [value] => 1
- [generic] => 2
- )
- [1] => Array
- (
- [descr] => OK
- [graph] => 0
- [value] => 2
- [generic] => 0
- )
- )
- )
- [13] => Array
- (
- [oid] => atsStatusSourceBStatus
- [value] => atsStatusSourceBStatus
- [state_name] => atsStatusSourceBStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.13.
- [index] => atsStatusSourceBStatus.{{ $index }}
- [descr] => Source B Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => Fail
- [graph] => 0
- [value] => 1
- [generic] => 2
- )
- [1] => Array
- (
- [descr] => OK
- [graph] => 0
- [value] => 2
- [generic] => 0
- )
- )
- )
- [14] => Array
- (
- [oid] => atsStatusSwitchStatus
- [value] => atsStatusSwitchStatus
- [state_name] => atsStatusSwitchStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.10.
- [index] => atsStatusSwitchStatus.{{ $index }}
- [descr] => Global Switch Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => Fail
- [graph] => 0
- [value] => 1
- [generic] => 2
- )
- [1] => Array
- (
- [descr] => OK
- [graph] => 0
- [value] => 2
- [generic] => 0
- )
- )
- )
- [15] => Array
- (
- [oid] => atsStatusSelectedSource
- [value] => atsStatusSelectedSource
- [state_name] => atsStatusSelectedSource
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.2.
- [index] => atsStatusSelectedSource.{{ $index }}
- [descr] => Selected Source
- [states] => Array
- (
- [0] => Array
- (
- [descr] => Source A
- [graph] => 0
- [value] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [descr] => Source B
- [graph] => 0
- [value] => 2
- [generic] => 3
- )
- )
- )
- [16] => Array
- (
- [oid] => atsStatusRedundancyState
- [value] => atsStatusRedundancyState
- [state_name] => atsStatusRedundancyState
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.3.
- [index] => atsStatusRedundancyState.{{ $index }}
- [descr] => Redundancy State
- [states] => Array
- (
- [0] => Array
- (
- [descr] => Redundancy Lost
- [graph] => 0
- [value] => 1
- [generic] => 2
- )
- [1] => Array
- (
- [descr] => Fully Redundant
- [graph] => 0
- [value] => 2
- [generic] => 0
- )
- )
- )
- [17] => Array
- (
- [oid] => atsStatusPhaseSyncStatus
- [value] => atsStatusPhaseSyncStatus
- [state_name] => atsStatusPhaseSyncStatus
- [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.14.
- [index] => atsStatusPhaseSyncStatus.{{ $index }}
- [descr] => Phase Sync Status
- [states] => Array
- (
- [0] => Array
- (
- [descr] => In Sync
- [graph] => 0
- [value] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => Out Of Sync
- [graph] => 0
- [value] => 2
- [generic] => 2
- )
- )
- )
- )
- )
- Data upsBasicOutputStatus: Array
- (
- )
- Data airIRRP100UnitStatusOperateMode: Array
- (
- )
- Data airIRRP100UnitStatusInputState: Array
- (
- )
- Data airIRRP100UnitStatusOutputState: Array
- (
- )
- Data airIRRP500UnitStatusOperateMode: Array
- (
- )
- Data airIRRP500UnitStatusInputState: Array
- (
- )
- Data airIRRP500UnitStatusOutputState: Array
- (
- )
- Data rPDU2PhaseStatusTable: Array
- (
- )
- Data rPDU2DeviceStatusTable: Array
- (
- )
- Data rPDU2DeviceStatusTable: Array
- (
- )
- Data rPDU2SensorTempHumidityStatusTable: Array
- (
- )
- Data rPDU2SensorTempHumidityStatusTable: Array
- (
- )
- Data atsStatusSourceAStatus: Array
- (
- )
- Data atsStatusSourceBStatus: Array
- (
- )
- Data atsStatusSwitchStatus: Array
- (
- )
- Data atsStatusSelectedSource: Array
- (
- )
- Data atsStatusRedundancyState: Array
- (
- )
- Data atsStatusPhaseSyncStatus: Array
- (
- )
- Array
- (
- [Relay] => Array
- (
- [.1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1] => 1
- )
- [Outlet] => Array
- (
- [.1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1] => 1
- )
- [memSensorsCommStatus] => Array
- (
- [memSensorsCommStatus.0.1] => 1
- )
- [memSensorsAlarmStatus] => Array
- (
- [memSensorsAlarmStatus.0.1] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",22,"snmp"][0m 1.5ms]
- .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1 -> Relay
- .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1 -> Outlet
- memSensorsCommStatus.0.1 -> memSensorsCommStatus
- memSensorsAlarmStatus.0.1 -> memSensorsAlarmStatus
- Temperature: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.2.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemConfigProbesTable[0m]
- iemConfigProbesTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemStatusProbesTable[0m]
- iemStatusProbesTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsProbeStatus[0m]
- emsProbeStatusProbeIndex.1 = 1
- emsProbeStatusProbeName.1 = "R/G4"
- emsProbeStatusProbeTemperature.1 = 22
- emsProbeStatusProbeHighTempThresh.1 = 27
- emsProbeStatusProbeLowTempThresh.1 = 18
- emsProbeStatusProbeHumidity.1 = 51
- emsProbeStatusProbeHighHumidityThresh.1 = 70
- emsProbeStatusProbeLowHumidityThresh.1 = 30
- emsProbeStatusProbeSerialNumber.1 = "L1"
- emsProbeStatusProbeCommStatus.1 = commsEstablished
- emsProbeStatusProbeAlarmStatus.1 = 0
- emsProbeStatusProbeMaxTempThresh.1 = 32
- emsProbeStatusProbeMinTempThresh.1 = 15
- emsProbeStatusProbeMaxHumidityThresh.1 = 80
- emsProbeStatusProbeMinHumidityThresh.1 = 20
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.13.1.1.3.1, 1, apc, R/G4, snmp, 1, 1, , 22
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",22,"apc","1"][0m 0.76ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",22,"apc","1"][0m 0.53ms]
- .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRCGroupSetpointsCoolMetric.0[0m]
- .*.4.1.3*.*.2.0 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.4.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.10.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.12.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.14.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitExtendedAnalogEntry[0m]
- coolingUnitExtendedAnalogEntry = No Such Object available on this agent at this OID
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/temperature/apc.inc.php on line 151
- Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.5.0.1, memSensorsTemperature.0.1, apc, R/G4 - Front of Rack, snmp, 1, 1, , 22
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",22,"apc","memSensorsTemperature.0.1"][0m 11.49ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",22,"apc","memSensorsTemperature.0.1"][0m 0.59ms]
- .Dynamic Discovery (temperature): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusRackInletTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3.
- [index] => airIRRP100UnitStatusRackInletTempMetric.{{ $index }}
- [descr] => Rack Inlet
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusSupplyAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5.
- [index] => airIRRP100UnitStatusSupplyAirTempMetric.{{ $index }}
- [descr] => Supply Air
- [divisor] => 10
- )
- [2] => Array
- (
- [oid] => airIRRP100UnitStatusReturnAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7.
- [index] => airIRRP100UnitStatusReturnAirTempMetric.{{ $index }}
- [descr] => Return Air
- [divisor] => 10
- )
- [3] => Array
- (
- [oid] => airIRRP100UnitStatusRackInletTemperature1Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24.
- [index] => airIRRP100UnitStatusRackInletTemperature1Metric.{{ $index }}
- [descr] => Inlet #1
- [divisor] => 10
- )
- [4] => Array
- (
- [oid] => airIRRP100UnitStatusRackInletTemperature2Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26.
- [index] => airIRRP100UnitStatusRackInletTemperature2Metric.{{ $index }}
- [descr] => Inlet #2
- [divisor] => 10
- )
- [5] => Array
- (
- [oid] => airIRRP100UnitStatusRackInletTemperature3Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28.
- [index] => airIRRP100UnitStatusRackInletTemperature3Metric.{{ $index }}
- [descr] => Inlet #3
- [divisor] => 10
- )
- [6] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41.
- [index] => airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric.{{ $index }}
- [descr] => Compressor Drive Heatsink
- [divisor] => 10
- )
- [7] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveControlCardTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43.
- [index] => airIRRP100UnitStatusCompressorDriveControlCardTempMetric.{{ $index }}
- [descr] => Compressor Drive Control Card
- [divisor] => 10
- )
- [8] => Array
- (
- [oid] => airIRRP500UnitStatusSupplyAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5.
- [index] => airIRRP500UnitStatusSupplyAirTempMetric.{{ $index }}
- [descr] => Supply Air
- [divisor] => 10
- )
- [9] => Array
- (
- [oid] => airIRRP500UnitStatusReturnAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7.
- [index] => airIRRP500UnitStatusReturnAirTempMetric.{{ $index }}
- [descr] => Return Air
- [divisor] => 10
- )
- [10] => Array
- (
- [oid] => airIRRP500UnitStatusRackInletTemperature1Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24.
- [index] => airIRRP500UnitStatusRackInletTemperature1Metric.{{ $index }}
- [descr] => Inlet #1
- [divisor] => 10
- )
- [11] => Array
- (
- [oid] => airIRRP500UnitStatusRackInletTemperature2Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26.
- [index] => airIRRP500UnitStatusRackInletTemperature2Metric.{{ $index }}
- [descr] => Inlet #2
- [divisor] => 10
- )
- [12] => Array
- (
- [oid] => airIRRP500UnitStatusRackInletTemperature3Metric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28.
- [index] => airIRRP500UnitStatusRackInletTemperature3Metric.{{ $index }}
- [descr] => Inlet #3
- [divisor] => 10
- )
- [13] => Array
- (
- [oid] => airIRG2RDT2StatusRackInletTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.7.
- [index] => airIRG2RDT2StatusRackInletTempMetric.{{ $index }}
- [descr] => Rack Inlet
- [divisor] => 10
- [high_limit] => airIRG2RDT2ThresholdsRackInletHighTempMetric
- )
- [14] => Array
- (
- [oid] => airIRG2RDT2StatusSupplyAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.9.
- [index] => airIRG2RDT2StatusSupplyAirTempMetric.{{ $index }}
- [descr] => Supply Air
- [divisor] => 10
- [high_limit] => airIRG2RDT2ThresholdsSupplyAirHighTempMetric
- )
- [15] => Array
- (
- [oid] => airIRG2RDT2StatusReturnAirTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.11.
- [index] => airIRG2RDT2StatusReturnAirTempMetric.{{ $index }}
- [descr] => Return Air
- [divisor] => 10
- [high_limit] => airIRG2RDT2ThresholdsReturnAirHighTempMetric
- )
- [16] => Array
- (
- [oid] => airIRG2RDT2StatusSuctionTempMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.13.
- [index] => airIRG2RDT2StatusSuctionTempMetric.{{ $index }}
- [descr] => Suction
- [divisor] => 10
- )
- [17] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusTable
- [value] => rPDU2SensorTempHumidityStatusTempC
- [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.8.
- [index] => rPDU2SensorTempHumidityStatusTempC.{{ $index }}
- [descr] => Temperature Probe
- [divisor] => 10
- [skip_values] => Array
- (
- [0] => Array
- (
- [oid] => rPDU2SensorTempHumidityStatusType
- [op] => =
- [value] => 4
- )
- )
- )
- )
- )
- Data airIRRP100UnitStatusRackInletTempMetric: Array
- (
- )
- Data airIRRP100UnitStatusSupplyAirTempMetric: Array
- (
- )
- Data airIRRP100UnitStatusReturnAirTempMetric: Array
- (
- )
- Data airIRRP100UnitStatusRackInletTemperature1Metric: Array
- (
- )
- Data airIRRP100UnitStatusRackInletTemperature2Metric: Array
- (
- )
- Data airIRRP100UnitStatusRackInletTemperature3Metric: Array
- (
- )
- Data airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric: Array
- (
- )
- Data airIRRP100UnitStatusCompressorDriveControlCardTempMetric: Array
- (
- )
- Data airIRRP500UnitStatusSupplyAirTempMetric: Array
- (
- )
- Data airIRRP500UnitStatusReturnAirTempMetric: Array
- (
- )
- Data airIRRP500UnitStatusRackInletTemperature1Metric: Array
- (
- )
- Data airIRRP500UnitStatusRackInletTemperature2Metric: Array
- (
- )
- Data airIRRP500UnitStatusRackInletTemperature3Metric: Array
- (
- )
- Data airIRG2RDT2StatusRackInletTempMetric: Array
- (
- )
- Data airIRG2RDT2StatusSupplyAirTempMetric: Array
- (
- )
- Data airIRG2RDT2StatusReturnAirTempMetric: Array
- (
- )
- Data airIRG2RDT2StatusSuctionTempMetric: Array
- (
- )
- Data rPDU2SensorTempHumidityStatusTable: Array
- (
- )
- Array
- (
- [apc] => Array
- (
- [1] => 1
- [memSensorsTemperature.0.1] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",22,"snmp"][0m 0.8ms]
- 1 -> apc
- memSensorsTemperature.0.1 -> apc
- Voltage: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.8.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.3.3.1.3[0m]
- .*.4.1.3*.*.3 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.4.3.1.3[0m]
- .*.4.1.3*.*.3 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.3.2.1.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.4.2.1.0[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.12.1.15.0[0m]
- .*.4.1.3*.1.15.0 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.26.6.3.1.6[0m]
- .*.4.1.3*.* No Such Object available on this agent at this OID
- Dynamic Discovery (voltage): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveVoltage
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37.
- [index] => airIRRP100UnitStatusCompressorDriveVoltage.{{ $index }}
- [descr] => Compressor Drive
- [divisor] => 10
- )
- [1] => Array
- (
- [oid] => airIRRP100UnitStatusCompressorDriveDCLinkVoltage
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39.
- [index] => airIRRP100UnitStatusCompressorDriveDCLinkVoltage.{{ $index }}
- [descr] => Compressor Drive DC Link
- [divisor] => 10
- )
- )
- )
- Data airIRRP100UnitStatusCompressorDriveVoltage: Array
- (
- )
- Data airIRRP100UnitStatusCompressorDriveDCLinkVoltage: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",22,"snmp"][0m 10.52ms]
- Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",22,"snmp"][0m 0.69ms]
- Pressure: Dynamic Discovery (pressure): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRG2RDT2StatusSuctionPressureMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.19.
- [index] => airIRG2RDT2StatusSuctionPressureMetric.{{ $index }}
- [descr] => Suction Pressure
- )
- [1] => Array
- (
- [oid] => airIRG2RDT2StatusDischargePressureMetric
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.21.
- [index] => airIRG2RDT2StatusDischargePressureMetric.{{ $index }}
- [descr] => Discharge Pressure
- )
- )
- )
- Data airIRG2RDT2StatusSuctionPressureMetric: Array
- (
- )
- Data airIRG2RDT2StatusDischargePressureMetric: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",22,"snmp"][0m 0.67ms]
- Cooling: Dynamic Discovery (cooling): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => airIRG2RDT2StatusCoolOutput
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.2.
- [index] => airIRG2RDT2StatusCoolOutput.{{ $index }}
- [descr] => Output
- [multiplier] => 100
- )
- [1] => Array
- (
- [oid] => airIRG2RDT2StatusCoolDemand
- [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.3.
- [index] => airIRG2RDT2StatusCoolDemand.{{ $index }}
- [descr] => Demand
- [multiplier] => 100
- )
- )
- )
- Data airIRG2RDT2StatusCoolOutput: Array
- (
- )
- Data airIRG2RDT2StatusCoolDemand: Array
- (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",22,"snmp"][0m 0.68ms]
- Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",22,"snmp"][0m 0.67ms]
- Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",22,"snmp"][0m 0.67ms]
- Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",22,"snmp"][0m 0.68ms]
- Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",22,"snmp"][0m 0.68ms]
- Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",22,"snmp"][0m 0.65ms]
- Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",22,"snmp"][0m 0.66ms]
- >> Runtime for discovery module 'sensors': 16.6700 seconds with 69032 bytes
- >> SNMP: [106/16.56s] MySQL: [52/0.07s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/datadomain udp:HOSTNAME:161 fileSystemSpaceTable[0m]
- fileSystemSpaceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dskTable[0m]
- dskTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '22' AND `storage_type` != 'dsk' [0;33m[][0m 0.46ms]
- SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '22' [0;33m[][0m 0.31ms]
- >> Runtime for discovery module 'storage': 0.3400 seconds with 9120 bytes
- >> SNMP: [3/0.34s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrDeviceEntry[0m]
- hrDeviceEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrProcessorEntry[0m]
- hrProcessorEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '22' [0;33m[][0m 1.35ms]
- >> Runtime for discovery module 'hr-device': 0.2600 seconds with 3704 bytes
- >> SNMP: [2/0.26s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 cdpCache[0m]
- cdpCache = No Such Object available on this agent at this OID
- LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 lldpRemTable[0m]
- OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[22][0m 0.68ms]
- SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[22][0m 1.05ms]
- SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.42ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.2450 seconds with 5048 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
- ipNetToPhysicalPhysAddress[1] = 0
- ipNetToPhysicalPhysAddress[2] = 0
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
- ipNetToMediaPhysAddress[2][*] = 0:c:29:25:28:3a
- ipNetToMediaPhysAddress[2][*] = 0:c:29:f7:5b:99
- SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[22,""][0m 1.07ms]
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,1][0m 1.11ms]
- Warning: Illegal string offset 'ipv4' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60
- LOOPBACK:
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,2][0m 1.03ms]
- Warning: Illegal string offset 'ipv4' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60
- vmac0:
- 0:c:29:25:28:3a => 10.0.2.9
- 0:c:29:f7:5b:99 => 10.0.2.251
- SQL[[1;33mDELETE FROM `ipv4_mac` WHERE `port_id` = ? AND `mac_address`=? AND `ipv4_address`=? AND `context_name`=? [0;33m[120,"005056980409","10.0.0.250",""][0m 2.45ms]
- SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 1.15ms]
- >> Runtime for discovery module 'arp-table': 0.4030 seconds with 27008 bytes
- >> SNMP: [0/0.00s] MySQL: [5/0.01s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os.
- Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module bgp-peers ####
- SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 bgpLocalAs[0m]
- "RMON-G-04"
- No BGP on hostPeers :
- SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[22,""][0m 0.54ms]
- SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[22,""][0m 0.51ms]
- SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[22][0m 0.63ms]
- >> Runtime for discovery module 'bgp-peers': 0.0330 seconds with 5624 bytes
- >> SNMP: [1/0.03s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[22][0m 0.59ms]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.1900 seconds with 9304 bytes
- >> SNMP: [2/0.19s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 diskIOEntry[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '22' [0;33m[][0m 0.91ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0940 seconds with 3160 bytes
- >> SNMP: [1/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS- Device Module [ applications ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 256 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS+ Device
- #### Load disco module stp ####
- SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[22][0m 0.77ms]
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0450 seconds with 5792 bytes
- >> SNMP: [1/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+ OS+ Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
- Modules status: Global- OS- Device Module [ mef ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module wireless ####
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ap-count"][0m 0.98ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"clients"][0m 1.59ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"quality"][0m 1.13ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"capacity"][0m 0.73ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"utilization"][0m 0.99ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"rate"][0m 0.75ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ccq"][0m 0.73ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"snr"][0m 0.67ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ssr"][0m 0.65ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"mse"][0m 0.65ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"rssi"][0m 2.04ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"power"][0m 2.52ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"noise-floor"][0m 0.69ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"errors"][0m 0.66ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"error-ratio"][0m 0.71ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"error-rate"][0m 0.68ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"frequency"][0m 0.66ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"distance"][0m 0.64ms]
- >> Runtime for discovery module 'wireless': 0.0250 seconds with 139432 bytes
- >> SNMP: [0/0.00s] MySQL: [18/0.02s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[22][0m 0.49ms]
- SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[22][0m 0.47ms]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1qTpFdbPort[0m]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dTpFdbPort[0m]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.2920 seconds with 2984 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"poll_mib"][0m 10.21ms]
- SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[21.991,22][0m 2.65ms]
- Discovered in 21.991 seconds
- SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.0.3.193","start":1541189540.1795,"duration":"22.18","devices":1,"poller":"soc-tools"}[0m 2.38ms]
- ./discovery.php 10.0.3.193 2018-11-02 15:12:42 - 1 devices discovered in 22.18 secs
- SNMP [135/19.50s]: Get[31/1.99s] Getnext[1/0.03s] Walk[103/17.48s]
- MySQL [110/0.14s]: Cell[24/0.05s] Row[-1/-0.01s] Rows[68/0.08s] Column[2/0.00s] Update[5/0.00s] Insert[6/0.02s] Delete[6/0.01s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]