LibreNMS Discovery SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.69ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.21ms] =================================== Version info: Commit SHA: eea8ced6e0802ac29d097be5d79ba4586225b1a5 Commit Date: 1541106551 DB Schema: 270 PHP: 7.2.11 MySQL: 10.2.18-MariaDB RRDTool: 1.6.0 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! Updating os_def.cache... Done SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.0.3.193' ORDER BY device_id DESC [0;33m[][0m 0.95ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[22][0m 0.45ms] 10.0.3.193 22 apc [FPING] /usr/sbin/fping -e -q -c 3 -p 500 -t 500 10.0.3.193 Array ( [xmt] => 3 [rcv] => 3 [loss] => 0 [min] => 0.80 [max] => 139 [avg] => 47.3 [exitcode] => 0 ) SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.80","max":"139","avg":"47.3","device_id":22}[0m 2.47ms] SNMP Check response code: 0 SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"poll_mib"][0m 1.32ms] Attempting to initialize OS: apc OS initilized as Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m] .*.*.0 = RMON-G-04 .*.*.0 = .*.4.1.3*.5 .*.*.0 = APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016) >> Runtime for discovery module 'core': 0.0410 seconds with 1184 bytes >> SNMP: [2/0.10s] MySQL: [4/0.01s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016) SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.3*.5 | APC Web/SNMP Management Card (MB:v4.1.0 PF:v6.4.6 PN:apc_hw05_aos_646.bin AF1:v6.4.6 AN1:apc_hw05_nb250_646.bin MN:NBRK0250 HR:05 SN: QA1647270817 MD:11/21/2016) | .1.3.6.1.4.1.318.1.3.8.5 | OS: APC Management Module (apc) >> Runtime for discovery module 'os': 0.1030 seconds with 1336 bytes >> SNMP: [2/0.10s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = LOOPBACK ifDescr.2 = vmac0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifName[0m] ifName = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifAlias[0m] ifAlias = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifType[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd Array ( [1] => Array ( [ifDescr] => LOOPBACK [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => vmac0 [ifType] => ethernetCsmacd ) ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[22][0m 1.41ms] .. >> Runtime for discovery module 'ports': 0.6100 seconds with 4136 bytes >> SNMP: [4/0.61s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '22' [0;33m[][0m 0.83ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ifStackStatus[0m] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.1330 seconds with 1784 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalEntry = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[22][0m 1.02ms] >> Runtime for discovery module 'entity-physical': 0.1620 seconds with 5504 bytes >> SNMP: [1/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrProcessorLoad[0m] hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[22][0m 1.49ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[22][0m 0.66ms] SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[22][0m 0.61ms] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m] No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[22][0m 0.89ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.62ms] >> Runtime for discovery module 'processors': 0.2030 seconds with 139592 bytes >> SNMP: [2/0.19s] MySQL: [5/0.01s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[22][0m 2.21ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '22' [0;33m[][0m 1.1ms] >> Runtime for discovery module 'mempools': 0.4260 seconds with 28648 bytes >> SNMP: [3/0.41s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[22][0m 0.6ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2664 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 2 ipAdEntIfIndex.* 1 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntNetMask.10.0.3.193[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[22,"2"][0m 0.72ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,"2"][0m 0.5ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.3.193\/20"][0m 0.51ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.0.3.193\/20"][0m 0.48ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.3.193\/20"][0m 0.53ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["10.0.3.193",20,120][0m 0.54ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.0.3.193",20,120][0m 0.46ms] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[22,"1"][0m 1.28ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,"1"][0m 0.61ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/32"][0m 0.34ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"127.0.0.1\/32"][0m 0.33ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/32"][0m 0.3ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["127.0.0.1",32,119][0m 0.35ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"127.0.0.1",32,119][0m 0.28ms] .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[22][0m 0.55ms] >> Runtime for discovery module 'ipv4-addresses': 0.1930 seconds with 34424 bytes >> SNMP: [3/0.18s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[22][0m 0.87ms] >> Runtime for discovery module 'ipv6-addresses': 0.2300 seconds with 3376 bytes >> SNMP: [2/0.23s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### Pre-cache apc: coolingUnitStatusAnalogEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitStatusAnalogEntry[0m] coolingUnitStatusAnalogEntry = No Such Object available on this agent at this OID upsPhaseNumInputPhases SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsPhaseNumInputPhases.1[0m] No Such Object available on this agent at this OID memSensorsStatusTable SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUse -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 memSensorsStatusTable[0m] memSensorsStatusModuleNumber.0.1 = 0 memSensorsStatusSensorNumber.0.1 = 1 memSensorsStatusSensorName.0.1 = "R/G4" memSensorsStatusSensorLocation.0.1 = "Front of Rack" memSensorsTemperature.0.1 = 22 memSensorsHumidity.0.1 = 51 memSensorsCommStatus.0.1 = 2 memSensorsAlarmStatus.0.1 = 1 memSensorsStatusSysTempUnits SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 memSensorsStatusSysTempUnits.0[0m] celsius Array ( [cooling_unit_analog] => Array ( ) [apcups_phase_count] => [mem_sensors_status] => Array ( [0.1] => Array ( [memSensorsStatusModuleNumber] => 0 [memSensorsStatusSensorNumber] => 1 [memSensorsStatusSensorName] => R/G4 [memSensorsStatusSensorLocation] => Front of Rack [memSensorsTemperature] => 22 [memSensorsHumidity] => 51 [memSensorsCommStatus] => 2 [memSensorsAlarmStatus] => 1 ) ) [memSensorsStatusSysTempUnits] => celsius ) Caching data: sensors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsRackInletHighTempMetric[0m] airIRG2RDT2ThresholdsRackInletHighTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsSupplyAirHighTempMetric[0m] airIRG2RDT2ThresholdsSupplyAirHighTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2ThresholdsReturnAirHighTempMetric[0m] airIRG2RDT2ThresholdsReturnAirHighTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsBasicOutputStatus[0m] upsBasicOutputStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusOperateMode[0m] airIRRP100UnitStatusOperateMode = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusInputState[0m] airIRRP100UnitStatusInputState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusOutputState[0m] airIRRP100UnitStatusOutputState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusOperateMode[0m] airIRRP500UnitStatusOperateMode = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusInputState[0m] airIRRP500UnitStatusInputState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusOutputState[0m] airIRRP500UnitStatusOutputState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2PhaseStatusTable[0m] rPDU2PhaseStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2DeviceStatusTable[0m] rPDU2DeviceStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDU2SensorTempHumidityStatusTable[0m] rPDU2SensorTempHumidityStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSourceAStatus[0m] atsStatusSourceAStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSourceBStatus[0m] atsStatusSourceBStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSwitchStatus[0m] atsStatusSwitchStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusSelectedSource[0m] atsStatusSelectedSource = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusRedundancyState[0m] atsStatusRedundancyState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsStatusPhaseSyncStatus[0m] atsStatusPhaseSyncStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTempMetric[0m] airIRRP100UnitStatusRackInletTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusSupplyAirTempMetric[0m] airIRRP100UnitStatusSupplyAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusReturnAirTempMetric[0m] airIRRP100UnitStatusReturnAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature1Metric[0m] airIRRP100UnitStatusRackInletTemperature1Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature2Metric[0m] airIRRP100UnitStatusRackInletTemperature2Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusRackInletTemperature3Metric[0m] airIRRP100UnitStatusRackInletTemperature3Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric[0m] airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveControlCardTempMetric[0m] airIRRP100UnitStatusCompressorDriveControlCardTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusSupplyAirTempMetric[0m] airIRRP500UnitStatusSupplyAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusReturnAirTempMetric[0m] airIRRP500UnitStatusReturnAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature1Metric[0m] airIRRP500UnitStatusRackInletTemperature1Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature2Metric[0m] airIRRP500UnitStatusRackInletTemperature2Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusRackInletTemperature3Metric[0m] airIRRP500UnitStatusRackInletTemperature3Metric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusRackInletTempMetric[0m] airIRG2RDT2StatusRackInletTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSupplyAirTempMetric[0m] airIRG2RDT2StatusSupplyAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusReturnAirTempMetric[0m] airIRG2RDT2StatusReturnAirTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSuctionTempMetric[0m] airIRG2RDT2StatusSuctionTempMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusSupplyHumidity[0m] airIRRP100UnitStatusSupplyHumidity = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusReturnHumidity[0m] airIRRP100UnitStatusReturnHumidity = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusSupplyHumidity[0m] airIRRP500UnitStatusSupplyHumidity = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusReturnHumidity[0m] airIRRP500UnitStatusReturnHumidity = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusAirFlowMetric[0m] airIRRP100UnitStatusAirFlowMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusAirFlowMetric[0m] airIRRP500UnitStatusAirFlowMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusAirFlowMetric[0m] airIRG2RDT2StatusAirFlowMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveVoltage[0m] airIRRP100UnitStatusCompressorDriveVoltage = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveDCLinkVoltage[0m] airIRRP100UnitStatusCompressorDriveDCLinkVoltage = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusHumidifierCurrent[0m] airIRRP100UnitStatusHumidifierCurrent = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveCurrent[0m] airIRRP100UnitStatusCompressorDriveCurrent = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusHumidifierCurrent[0m] airIRRP500UnitStatusHumidifierCurrent = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusFanSpeed[0m] airIRRP100UnitStatusFanSpeed = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusFanSpeed[0m] airIRRP500UnitStatusFanSpeed = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDriveSpeed[0m] airIRRP100UnitStatusCompressorDriveSpeed = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCompressorDrivePower[0m] airIRRP100UnitStatusCompressorDrivePower = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCoolDemand[0m] airIRRP100UnitStatusCoolDemand = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100UnitStatusCoolOutput[0m] airIRRP100UnitStatusCoolOutput = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusCoolDemand[0m] airIRRP500UnitStatusCoolDemand = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP500UnitStatusCoolOutput[0m] airIRRP500UnitStatusCoolOutput = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusSuctionPressureMetric[0m] airIRG2RDT2StatusSuctionPressureMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusDischargePressureMetric[0m] airIRG2RDT2StatusDischargePressureMetric = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusCoolOutput[0m] airIRG2RDT2StatusCoolOutput = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRG2RDT2StatusCoolDemand[0m] airIRG2RDT2StatusCoolDemand = No Such Object available on this agent at this OID ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr = No Such Object available on this agent at this OID SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"ipmi_hostname"][0m 0.52ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",22,"ipmi"][0m 0.7ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",22,"ipmi"][0m 0.67ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",22,"ipmi"][0m 0.55ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",22,"ipmi"][0m 0.56ms] Airflow: Dynamic Discovery (airflow): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusAirFlowMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.11. [index] => airIRRP100UnitStatusAirFlowMetric.{{ $index }} [descr] => Air Flow [divisor] => 10 ) [1] => Array ( [oid] => airIRRP500UnitStatusAirFlowMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.11. [index] => airIRRP500UnitStatusAirFlowMetric.{{ $index }} [descr] => Air Flow [divisor] => 10 ) [2] => Array ( [oid] => airIRG2RDT2StatusAirFlowMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.5. [index] => airIRG2RDT2StatusAirFlowMetric.{{ $index }} [descr] => Air Flow ) ) ) Data airIRRP100UnitStatusAirFlowMetric: Array ( ) Data airIRRP500UnitStatusAirFlowMetric: Array ( ) Data airIRG2RDT2StatusAirFlowMetric: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",22,"snmp"][0m 0.57ms] Current: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDUStatusPhaseIndex[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDULoadPhaseConfigIndex[0m] .*.4.1.3*.*.1 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 rPDULoadDevNumBanks.0[0m] No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -t 30 -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.26.9.4.3.1.1[0m] .*.4.1.3*.*.1 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 atsConfigPhaseTableIndex[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsHighPrecOutputCurrent[0m] upsHighPrecOutputCurrent = No Such Object available on this agent at this OID Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/current/apc.inc.php on line 202 Dynamic Discovery (current): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusHumidifierCurrent [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.33. [index] => airIRRP100UnitStatusHumidifierCurrent.{{ $index }} [descr] => Humidifier [divisor] => 10 ) [1] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveCurrent [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.38. [index] => airIRRP100UnitStatusCompressorDriveCurrent.{{ $index }} [descr] => Compressor Drive [divisor] => 10 ) [2] => Array ( [oid] => airIRRP500UnitStatusHumidifierCurrent [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.33. [index] => airIRRP100UnitStatusHumidifierCurrent.{{ $index }} [descr] => Humidifier [divisor] => 10 ) ) ) Data airIRRP100UnitStatusHumidifierCurrent: Array ( ) Data airIRRP100UnitStatusCompressorDriveCurrent: Array ( ) Data airIRRP500UnitStatusHumidifierCurrent: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",22,"snmp"][0m 1.07ms] Charge: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.3.1.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.1.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",22,"snmp"][0m 1.09ms] Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",22,"snmp"][0m 0.77ms] Fanspeed: Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/fanspeed/apc.inc.php on line 26 Dynamic Discovery (fanspeed): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusFanSpeed [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.12. [index] => airIRRP100UnitStatusFanSpeed.{{ $index }} [descr] => Fan Speed (%) [divisor] => 10 ) [1] => Array ( [oid] => airIRRP500UnitStatusFanSpeed [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.12. [index] => airIRRP500UnitStatusFanSpeed.{{ $index }} [descr] => Fan Speed (%) [divisor] => 10 ) ) ) Data airIRRP100UnitStatusFanSpeed: Array ( ) Data airIRRP500UnitStatusFanSpeed: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",22,"snmp"][0m 0.81ms] Frequency: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.3.2.1.4[0m] .*.4.1.3*.*.4 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.4.2.1.4[0m] .*.4.1.3*.*.4 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.3.2.4.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.4.2.2.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID Dynamic Discovery (frequency): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveSpeed [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35. [index] => airIRRP100UnitStatusCompressorDriveSpeed.{{ $index }} [descr] => Drive Speed [divisor] => 10 ) ) ) Data airIRRP100UnitStatusCompressorDriveSpeed: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",22,"snmp"][0m 1.34ms] Humidity: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemConfigProbesTable[0m] iemConfigProbesTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemStatusProbesTable[0m] iemStatusProbesTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsProbeStatus[0m] emsProbeStatusProbeIndex.1 = 1 emsProbeStatusProbeName.1 = "R/G4" emsProbeStatusProbeTemperature.1 = 22 emsProbeStatusProbeHighTempThresh.1 = 27 emsProbeStatusProbeLowTempThresh.1 = 18 emsProbeStatusProbeHumidity.1 = 51 emsProbeStatusProbeHighHumidityThresh.1 = 70 emsProbeStatusProbeLowHumidityThresh.1 = 30 emsProbeStatusProbeSerialNumber.1 = "L1" emsProbeStatusProbeCommStatus.1 = commsEstablished emsProbeStatusProbeAlarmStatus.1 = 0 emsProbeStatusProbeMaxTempThresh.1 = 32 emsProbeStatusProbeMinTempThresh.1 = 15 emsProbeStatusProbeMaxHumidityThresh.1 = 80 emsProbeStatusProbeMinHumidityThresh.1 = 20 Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.13.1.1.6.1, 1, apc, R/G4, snmp, 1, 1, , 51 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","humidity",22,"apc","1"][0m 15.25ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["humidity",22,"apc","1"][0m 0.84ms] .Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.6.0.1, memSensorsHumidity.0.1, apc, R/G4 - Front of Rack, snmp, 1, 1, , 51 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","humidity",22,"apc","memSensorsHumidity.0.1"][0m 0.72ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["humidity",22,"apc","memSensorsHumidity.0.1"][0m 0.75ms] .Dynamic Discovery (humidity): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusSupplyHumidity [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8. [index] => airIRRP100UnitStatusSupplyHumidity.{{ $index }} [descr] => Supply [divisor] => 10 ) [1] => Array ( [oid] => airIRRP100UnitStatusReturnHumidity [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.8. [index] => airIRRP100UnitStatusReturnHumidity.{{ $index }} [descr] => Return [divisor] => 10 ) [2] => Array ( [oid] => airIRRP500UnitStatusSupplyHumidity [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8. [index] => airIRRP500UnitStatusSupplyHumidity.{{ $index }} [descr] => Supply [divisor] => 10 ) [3] => Array ( [oid] => airIRRP500UnitStatusReturnHumidity [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.8. [index] => airIRRP500UnitStatusSupplyHumidity.{{ $index }} [descr] => Return [divisor] => 10 ) [4] => Array ( [oid] => rPDU2SensorTempHumidityStatusTable [value] => rPDU2SensorTempHumidityStatusRelativeHumidity [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.10. [index] => rPDU2SensorTempHumidityStatusRelativeHumidity.{{ $index }} [descr] => Humidity Probe [skip_values] => Array ( [0] => Array ( [oid] => rPDU2SensorTempHumidityStatusType [op] => = [value] => 4 ) [1] => Array ( [oid] => rPDU2SensorTempHumidityStatusRelativeHumidity [op] => < [value] => 0 ) ) ) ) ) Data airIRRP100UnitStatusSupplyHumidity: Array ( ) Data airIRRP100UnitStatusReturnHumidity: Array ( ) Data airIRRP500UnitStatusSupplyHumidity: Array ( ) Data airIRRP500UnitStatusReturnHumidity: Array ( ) Data rPDU2SensorTempHumidityStatusTable: Array ( ) Array ( [apc] => Array ( [1] => 1 [memSensorsHumidity.0.1] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",22,"snmp"][0m 1.15ms] 1 -> apc memSensorsHumidity.0.1 -> apc Load: APC Load SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m +PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsHighPrecOutputLoad.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m +PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsAdvOutputLoad.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",22,"snmp"][0m 1.81ms] Power: Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/power/apc.inc.php on line 26 Dynamic Discovery (power): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusCompressorDrivePower [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.35. [index] => airIRRP100UnitStatusCompressorDrivePower.{{ $index }} [descr] => Drive Power [multiplier] => 10 ) [1] => Array ( [oid] => airIRRP100UnitStatusCoolDemand [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.13. [index] => airIRRP100UnitStatusCoolDemand.{{ $index }} [descr] => Cooling Demand [multiplier] => 100 ) [2] => Array ( [oid] => airIRRP100UnitStatusCoolOutput [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.14. [index] => airIRRP100UnitStatusCoolOutput.{{ $index }} [descr] => Cooling Output [multiplier] => 100 ) [3] => Array ( [oid] => airIRRP500UnitStatusCoolDemand [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.13. [index] => airIRRP500UnitStatusCoolDemand.{{ $index }} [descr] => Cooling Demand [multiplier] => 100 ) [4] => Array ( [oid] => airIRRP500UnitStatusCoolOutput [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.14. [index] => airIRRP500UnitStatusCoolOutput.{{ $index }} [descr] => Cooling Output [multiplier] => 100 ) [5] => Array ( [oid] => rPDU2DeviceStatusTable [value] => rPDU2DeviceStatusPower [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.5. [multiplier] => 10 [index] => rPDU2DeviceStatusPower.{{ $index }} [descr] => Power, Total ) ) ) Data airIRRP100UnitStatusCompressorDrivePower: Array ( ) Data airIRRP100UnitStatusCoolDemand: Array ( ) Data airIRRP100UnitStatusCoolOutput: Array ( ) Data airIRRP500UnitStatusCoolDemand: Array ( ) Data airIRRP500UnitStatusCoolOutput: Array ( ) Data rPDU2DeviceStatusTable: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",22,"snmp"][0m 0.77ms] Runtime: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnUt -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.3.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRP100GroupSetpointsCoolMetric.0[0m] .*.4.1.3*.*.2.2.0 No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",22,"snmp"][0m 1.1ms] Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",22,"snmp"][0m 0.65ms] State: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 upsAdvBatteryReplaceIndicator.0[0m] No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitStatusDiscreteEntry[0m] coolingUnitStatusDiscreteEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitExtendedDiscreteEntry[0m] coolingUnitExtendedDiscreteEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsOutputRelayControlEntry[0m] emsOutputRelayControlOutputRelayIndex.1 = 1 emsOutputRelayControlOutputRelayName.1 = "Relay" emsOutputRelayControlOutputRelayCommand.1 = immediateOpenEMS SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["Relay"][0m 0.78ms] SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[1][0m 0.8ms] Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1, .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1, Relay, Relay, snmp, 1, 1, , 2 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.97ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.89ms] .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Relay",".1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1"][0m 0.67ms] SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["Relay"][0m 0.48ms] SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":227,"state_index_id":1}[0m 2.19ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsOutletControlEntry[0m] emsOutletControlOutletIndex.1 = 1 emsOutletControlOutletName.1 = "Outlet" emsOutletControlOutletCommand.1 = immediateOffEMS SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["Outlet"][0m 1.41ms] SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[2][0m 1.62ms] Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1, .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1, Outlet, Outlet, snmp, 1, 1, , 2 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 0.98ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 2.89ms] .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"Outlet",".1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1"][0m 0.73ms] SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["Outlet"][0m 0.49ms] SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":228,"state_index_id":2}[0m 2.21ms] SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["memSensorsCommStatus"][0m 0.57ms] SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[3][0m 0.66ms] Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.7.0.1, memSensorsCommStatus.0.1, memSensorsCommStatus, memSensorsCommStatus, snmp, 1, 1, , 2 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.82ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.94ms] .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsCommStatus","memSensorsCommStatus.0.1"][0m 0.77ms] SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["memSensorsCommStatus"][0m 0.53ms] SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":229,"state_index_id":3}[0m 2.06ms] SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["memSensorsAlarmStatus"][0m 0.54ms] SQL[[1;33mSELECT * FROM `state_translations` WHERE `state_index_id` = ? [0;33m[4][0m 0.64ms] Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.8.0.1, memSensorsAlarmStatus.0.1, memSensorsAlarmStatus, memSensorsAlarmStatus, snmp, 1, 1, , 1 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.79ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.98ms] .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",22,"memSensorsAlarmStatus","memSensorsAlarmStatus.0.1"][0m 0.79ms] SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["memSensorsAlarmStatus"][0m 0.52ms] SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":230,"state_index_id":4}[0m 2.35ms] Dynamic Discovery (state): Array ( [data] => Array ( [0] => Array ( [oid] => upsBasicOutputStatus [value] => upsBasicOutputStatus [num_oid] => .1.3.6.1.4.1.318.1.1.1.4.1.1. [descr] => Output Status [index] => {{ $index }} [state_name] => upsBasicOutputStatus [states] => Array ( [0] => Array ( [descr] => unknown [graph] => 0 [value] => 1 [generic] => 3 ) [1] => Array ( [descr] => onLine [graph] => 0 [value] => 2 [generic] => 0 ) [2] => Array ( [descr] => onBattery [graph] => 0 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => onSmartBoost [graph] => 0 [value] => 4 [generic] => 0 ) [4] => Array ( [descr] => timedSleeping [graph] => 0 [value] => 5 [generic] => 0 ) [5] => Array ( [descr] => softwareBypass [graph] => 0 [value] => 6 [generic] => 1 ) [6] => Array ( [descr] => off [graph] => 0 [value] => 7 [generic] => 2 ) [7] => Array ( [descr] => rebooting [graph] => 0 [value] => 8 [generic] => 1 ) [8] => Array ( [descr] => switchedBypass [graph] => 0 [value] => 9 [generic] => 1 ) [9] => Array ( [descr] => hardwareFailureBypass [graph] => 0 [value] => 10 [generic] => 2 ) [10] => Array ( [descr] => sleepingUntilPowerReturn [graph] => 0 [value] => 11 [generic] => 1 ) [11] => Array ( [descr] => onSmartTrim [graph] => 0 [value] => 12 [generic] => 1 ) [12] => Array ( [descr] => ecoMode [graph] => 0 [value] => 13 [generic] => 0 ) [13] => Array ( [descr] => hotStandby [graph] => 0 [value] => 14 [generic] => 0 ) [14] => Array ( [descr] => onBatteryTest [graph] => 0 [value] => 15 [generic] => 1 ) [15] => Array ( [descr] => emergencyStaticBypass [graph] => 0 [value] => 16 [generic] => 2 ) [16] => Array ( [descr] => staticBypassStandby [graph] => 0 [value] => 17 [generic] => 1 ) [17] => Array ( [descr] => powerSavingMode [graph] => 0 [value] => 18 [generic] => 0 ) [18] => Array ( [descr] => spotMode [graph] => 0 [value] => 19 [generic] => 0 ) [19] => Array ( [descr] => eConversion [graph] => 0 [value] => 20 [generic] => 0 ) [20] => Array ( [descr] => chargerSpotmode [graph] => 0 [value] => 21 [generic] => 0 ) [21] => Array ( [descr] => inverterSpotmode [graph] => 0 [value] => 22 [generic] => 0 ) ) ) [1] => Array ( [oid] => airIRRP100UnitStatusOperateMode [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.1. [descr] => Unit Status [states] => Array ( [0] => Array ( [descr] => standby [graph] => 1 [value] => 1 [generic] => 1 ) [1] => Array ( [descr] => on [graph] => 1 [value] => 2 [generic] => 0 ) [2] => Array ( [descr] => idle [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => prestart [graph] => 1 [value] => 4 [generic] => 1 ) [4] => Array ( [descr] => service [graph] => 1 [value] => 5 [generic] => 1 ) [5] => Array ( [descr] => backup [graph] => 1 [value] => 6 [generic] => 1 ) [6] => Array ( [descr] => assist [graph] => 1 [value] => 7 [generic] => 1 ) ) ) [2] => Array ( [oid] => airIRRP100UnitStatusInputState [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.21. [descr] => Input State [states] => Array ( [0] => Array ( [descr] => open [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => closed [graph] => 1 [value] => 2 [generic] => 2 ) ) ) [3] => Array ( [oid] => airIRRP100UnitStatusOutputState [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.22. [descr] => Output State [states] => Array ( [0] => Array ( [descr] => open [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => closed [graph] => 1 [value] => 2 [generic] => 2 ) ) ) [4] => Array ( [oid] => airIRRP500UnitStatusOperateMode [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.1. [descr] => Unit Status [states] => Array ( [0] => Array ( [descr] => standby [graph] => 1 [value] => 1 [generic] => 1 ) [1] => Array ( [descr] => on [graph] => 1 [value] => 2 [generic] => 0 ) [2] => Array ( [descr] => idle [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => prestart [graph] => 1 [value] => 4 [generic] => 1 ) [4] => Array ( [descr] => backup [graph] => 1 [value] => 5 [generic] => 1 ) [5] => Array ( [descr] => assist [graph] => 1 [value] => 6 [generic] => 1 ) ) ) [5] => Array ( [oid] => airIRRP500UnitStatusInputState [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.21. [descr] => Input State [states] => Array ( [0] => Array ( [descr] => open [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => closed [graph] => 1 [value] => 2 [generic] => 2 ) ) ) [6] => Array ( [oid] => airIRRP500UnitStatusOutputState [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.22. [descr] => Output State [states] => Array ( [0] => Array ( [descr] => open [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => closed [graph] => 1 [value] => 2 [generic] => 2 ) ) ) [7] => Array ( [oid] => rPDU2PhaseStatusTable [state_name] => rPDU2PhaseStatusLoadState [value] => rPDU2PhaseStatusLoadState [num_oid] => .1.3.6.1.4.1.318.1.1.26.6.3.1.4. [index] => rPDU2PhaseStatusLoadState.{{ $index }} [descr] => Load State, Phase #{{ $index }} [states] => Array ( [0] => Array ( [descr] => lowLoad [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => normal [graph] => 1 [value] => 2 [generic] => 0 ) [2] => Array ( [descr] => nearOverload [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => overload [graph] => 1 [value] => 4 [generic] => 2 ) ) ) [8] => Array ( [oid] => rPDU2DeviceStatusTable [state_name] => rPDU2DeviceStatusLoadState [value] => rPDU2DeviceStatusLoadState [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.4. [index] => rPDU2DeviceStatusLoadState.{{ $index }} [descr] => Device State [states] => Array ( [0] => Array ( [descr] => lowLoad [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => normal [graph] => 1 [value] => 2 [generic] => 0 ) [2] => Array ( [descr] => nearOverload [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => overload [graph] => 1 [value] => 4 [generic] => 2 ) [4] => Array ( [descr] => notsupported [graph] => 1 [value] => 5 [generic] => 3 ) ) ) [9] => Array ( [oid] => rPDU2DeviceStatusTable [state_name] => rPDU2DeviceStatusPowerSupplyAlarm [value] => rPDU2DeviceStatusPowerSupplyAlarm [num_oid] => .1.3.6.1.4.1.318.1.1.26.4.3.1.12. [index] => rPDU2DeviceStatusPowerSupplyAlarm.{{ $index }} [descr] => Power Supply State [states] => Array ( [0] => Array ( [descr] => normal [graph] => 1 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => alarm [graph] => 1 [value] => 2 [generic] => 2 ) ) ) [10] => Array ( [oid] => rPDU2SensorTempHumidityStatusTable [state_name] => rPDU2SensorTempHumidityStatusTempStatus [value] => rPDU2SensorTempHumidityStatusTempStatus [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.9. [index] => rPDU2SensorTempHumidityStatusTempStatus.{{ $index }} [descr] => Temperature Probe Status [states] => Array ( [0] => Array ( [descr] => notPresent [graph] => 1 [value] => 1 [generic] => 3 ) [1] => Array ( [descr] => belowMin [graph] => 1 [value] => 2 [generic] => 2 ) [2] => Array ( [descr] => belowLow [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => normal [graph] => 1 [value] => 4 [generic] => 0 ) [4] => Array ( [descr] => aboveHigh [graph] => 1 [value] => 5 [generic] => 1 ) [5] => Array ( [descr] => aboveMax [graph] => 1 [value] => 6 [generic] => 2 ) ) [skip_values] => Array ( [0] => Array ( [oid] => rPDU2SensorTempHumidityStatusTempStatus [op] => = [value] => 1 ) ) ) [11] => Array ( [oid] => rPDU2SensorTempHumidityStatusTable [state_name] => rPDU2SensorTempHumidityStatusHumidityStatus [value] => rPDU2SensorTempHumidityStatusHumidityStatus [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.11. [index] => rPDU2SensorTempHumidityStatusHumidityStatus.{{ $index }} [descr] => Humidity Probe Status [states] => Array ( [0] => Array ( [descr] => notPresent [graph] => 1 [value] => 1 [generic] => 3 ) [1] => Array ( [descr] => belowMin [graph] => 1 [value] => 2 [generic] => 2 ) [2] => Array ( [descr] => belowLow [graph] => 1 [value] => 3 [generic] => 1 ) [3] => Array ( [descr] => normal [graph] => 1 [value] => 4 [generic] => 0 ) [4] => Array ( [descr] => aboveHigh [graph] => 1 [value] => 5 [generic] => 1 ) [5] => Array ( [descr] => aboveMax [graph] => 1 [value] => 6 [generic] => 2 ) ) [skip_values] => Array ( [0] => Array ( [oid] => rPDU2SensorTempHumidityStatusHumidityStatus [op] => = [value] => 1 ) ) ) [12] => Array ( [oid] => atsStatusSourceAStatus [value] => atsStatusSourceAStatus [state_name] => atsStatusSourceAStatus [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.12. [index] => atsStatusSourceAStatus.{{ $index }} [descr] => Source A Status [states] => Array ( [0] => Array ( [descr] => Fail [graph] => 0 [value] => 1 [generic] => 2 ) [1] => Array ( [descr] => OK [graph] => 0 [value] => 2 [generic] => 0 ) ) ) [13] => Array ( [oid] => atsStatusSourceBStatus [value] => atsStatusSourceBStatus [state_name] => atsStatusSourceBStatus [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.13. [index] => atsStatusSourceBStatus.{{ $index }} [descr] => Source B Status [states] => Array ( [0] => Array ( [descr] => Fail [graph] => 0 [value] => 1 [generic] => 2 ) [1] => Array ( [descr] => OK [graph] => 0 [value] => 2 [generic] => 0 ) ) ) [14] => Array ( [oid] => atsStatusSwitchStatus [value] => atsStatusSwitchStatus [state_name] => atsStatusSwitchStatus [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.10. [index] => atsStatusSwitchStatus.{{ $index }} [descr] => Global Switch Status [states] => Array ( [0] => Array ( [descr] => Fail [graph] => 0 [value] => 1 [generic] => 2 ) [1] => Array ( [descr] => OK [graph] => 0 [value] => 2 [generic] => 0 ) ) ) [15] => Array ( [oid] => atsStatusSelectedSource [value] => atsStatusSelectedSource [state_name] => atsStatusSelectedSource [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.2. [index] => atsStatusSelectedSource.{{ $index }} [descr] => Selected Source [states] => Array ( [0] => Array ( [descr] => Source A [graph] => 0 [value] => 1 [generic] => 3 ) [1] => Array ( [descr] => Source B [graph] => 0 [value] => 2 [generic] => 3 ) ) ) [16] => Array ( [oid] => atsStatusRedundancyState [value] => atsStatusRedundancyState [state_name] => atsStatusRedundancyState [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.3. [index] => atsStatusRedundancyState.{{ $index }} [descr] => Redundancy State [states] => Array ( [0] => Array ( [descr] => Redundancy Lost [graph] => 0 [value] => 1 [generic] => 2 ) [1] => Array ( [descr] => Fully Redundant [graph] => 0 [value] => 2 [generic] => 0 ) ) ) [17] => Array ( [oid] => atsStatusPhaseSyncStatus [value] => atsStatusPhaseSyncStatus [state_name] => atsStatusPhaseSyncStatus [num_oid] => .1.3.6.1.4.1.318.1.1.8.5.1.14. [index] => atsStatusPhaseSyncStatus.{{ $index }} [descr] => Phase Sync Status [states] => Array ( [0] => Array ( [descr] => In Sync [graph] => 0 [value] => 1 [generic] => 0 ) [1] => Array ( [descr] => Out Of Sync [graph] => 0 [value] => 2 [generic] => 2 ) ) ) ) ) Data upsBasicOutputStatus: Array ( ) Data airIRRP100UnitStatusOperateMode: Array ( ) Data airIRRP100UnitStatusInputState: Array ( ) Data airIRRP100UnitStatusOutputState: Array ( ) Data airIRRP500UnitStatusOperateMode: Array ( ) Data airIRRP500UnitStatusInputState: Array ( ) Data airIRRP500UnitStatusOutputState: Array ( ) Data rPDU2PhaseStatusTable: Array ( ) Data rPDU2DeviceStatusTable: Array ( ) Data rPDU2DeviceStatusTable: Array ( ) Data rPDU2SensorTempHumidityStatusTable: Array ( ) Data rPDU2SensorTempHumidityStatusTable: Array ( ) Data atsStatusSourceAStatus: Array ( ) Data atsStatusSourceBStatus: Array ( ) Data atsStatusSwitchStatus: Array ( ) Data atsStatusSelectedSource: Array ( ) Data atsStatusRedundancyState: Array ( ) Data atsStatusPhaseSyncStatus: Array ( ) Array ( [Relay] => Array ( [.1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1] => 1 ) [Outlet] => Array ( [.1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1] => 1 ) [memSensorsCommStatus] => Array ( [memSensorsCommStatus.0.1] => 1 ) [memSensorsAlarmStatus] => Array ( [memSensorsAlarmStatus.0.1] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",22,"snmp"][0m 1.5ms] .1.3.6.1.4.1.318.1.1.10.3.2.1.1.3.1 -> Relay .1.3.6.1.4.1.318.1.1.10.3.3.1.1.3.1 -> Outlet memSensorsCommStatus.0.1 -> memSensorsCommStatus memSensorsAlarmStatus.0.1 -> memSensorsAlarmStatus Temperature: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.2.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemConfigProbesTable[0m] iemConfigProbesTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 iemStatusProbesTable[0m] iemStatusProbesTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 emsProbeStatus[0m] emsProbeStatusProbeIndex.1 = 1 emsProbeStatusProbeName.1 = "R/G4" emsProbeStatusProbeTemperature.1 = 22 emsProbeStatusProbeHighTempThresh.1 = 27 emsProbeStatusProbeLowTempThresh.1 = 18 emsProbeStatusProbeHumidity.1 = 51 emsProbeStatusProbeHighHumidityThresh.1 = 70 emsProbeStatusProbeLowHumidityThresh.1 = 30 emsProbeStatusProbeSerialNumber.1 = "L1" emsProbeStatusProbeCommStatus.1 = commsEstablished emsProbeStatusProbeAlarmStatus.1 = 0 emsProbeStatusProbeMaxTempThresh.1 = 32 emsProbeStatusProbeMinTempThresh.1 = 15 emsProbeStatusProbeMaxHumidityThresh.1 = 80 emsProbeStatusProbeMinHumidityThresh.1 = 20 Discover sensor: .1.3.6.1.4.1.318.1.1.10.3.13.1.1.3.1, 1, apc, R/G4, snmp, 1, 1, , 22 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",22,"apc","1"][0m 0.76ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",22,"apc","1"][0m 0.53ms] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 airIRRCGroupSetpointsCoolMetric.0[0m] .*.4.1.3*.*.2.0 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.4.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.10.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.12.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.13.2.2.14.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m PowerNet-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 coolingUnitExtendedAnalogEntry[0m] coolingUnitExtendedAnalogEntry = No Such Object available on this agent at this OID Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/sensors/temperature/apc.inc.php on line 151 Discover sensor: .1.3.6.1.4.1.318.1.1.10.4.2.3.1.5.0.1, memSensorsTemperature.0.1, apc, R/G4 - Front of Rack, snmp, 1, 1, , 22 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",22,"apc","memSensorsTemperature.0.1"][0m 11.49ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",22,"apc","memSensorsTemperature.0.1"][0m 0.59ms] .Dynamic Discovery (temperature): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusRackInletTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.3. [index] => airIRRP100UnitStatusRackInletTempMetric.{{ $index }} [descr] => Rack Inlet [divisor] => 10 ) [1] => Array ( [oid] => airIRRP100UnitStatusSupplyAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.5. [index] => airIRRP100UnitStatusSupplyAirTempMetric.{{ $index }} [descr] => Supply Air [divisor] => 10 ) [2] => Array ( [oid] => airIRRP100UnitStatusReturnAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.7. [index] => airIRRP100UnitStatusReturnAirTempMetric.{{ $index }} [descr] => Return Air [divisor] => 10 ) [3] => Array ( [oid] => airIRRP100UnitStatusRackInletTemperature1Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.24. [index] => airIRRP100UnitStatusRackInletTemperature1Metric.{{ $index }} [descr] => Inlet #1 [divisor] => 10 ) [4] => Array ( [oid] => airIRRP100UnitStatusRackInletTemperature2Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.26. [index] => airIRRP100UnitStatusRackInletTemperature2Metric.{{ $index }} [descr] => Inlet #2 [divisor] => 10 ) [5] => Array ( [oid] => airIRRP100UnitStatusRackInletTemperature3Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.28. [index] => airIRRP100UnitStatusRackInletTemperature3Metric.{{ $index }} [descr] => Inlet #3 [divisor] => 10 ) [6] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.41. [index] => airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric.{{ $index }} [descr] => Compressor Drive Heatsink [divisor] => 10 ) [7] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveControlCardTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.43. [index] => airIRRP100UnitStatusCompressorDriveControlCardTempMetric.{{ $index }} [descr] => Compressor Drive Control Card [divisor] => 10 ) [8] => Array ( [oid] => airIRRP500UnitStatusSupplyAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.5. [index] => airIRRP500UnitStatusSupplyAirTempMetric.{{ $index }} [descr] => Supply Air [divisor] => 10 ) [9] => Array ( [oid] => airIRRP500UnitStatusReturnAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.7. [index] => airIRRP500UnitStatusReturnAirTempMetric.{{ $index }} [descr] => Return Air [divisor] => 10 ) [10] => Array ( [oid] => airIRRP500UnitStatusRackInletTemperature1Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.24. [index] => airIRRP500UnitStatusRackInletTemperature1Metric.{{ $index }} [descr] => Inlet #1 [divisor] => 10 ) [11] => Array ( [oid] => airIRRP500UnitStatusRackInletTemperature2Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.26. [index] => airIRRP500UnitStatusRackInletTemperature2Metric.{{ $index }} [descr] => Inlet #2 [divisor] => 10 ) [12] => Array ( [oid] => airIRRP500UnitStatusRackInletTemperature3Metric [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.2.2.2.28. [index] => airIRRP500UnitStatusRackInletTemperature3Metric.{{ $index }} [descr] => Inlet #3 [divisor] => 10 ) [13] => Array ( [oid] => airIRG2RDT2StatusRackInletTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.7. [index] => airIRG2RDT2StatusRackInletTempMetric.{{ $index }} [descr] => Rack Inlet [divisor] => 10 [high_limit] => airIRG2RDT2ThresholdsRackInletHighTempMetric ) [14] => Array ( [oid] => airIRG2RDT2StatusSupplyAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.9. [index] => airIRG2RDT2StatusSupplyAirTempMetric.{{ $index }} [descr] => Supply Air [divisor] => 10 [high_limit] => airIRG2RDT2ThresholdsSupplyAirHighTempMetric ) [15] => Array ( [oid] => airIRG2RDT2StatusReturnAirTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.11. [index] => airIRG2RDT2StatusReturnAirTempMetric.{{ $index }} [descr] => Return Air [divisor] => 10 [high_limit] => airIRG2RDT2ThresholdsReturnAirHighTempMetric ) [16] => Array ( [oid] => airIRG2RDT2StatusSuctionTempMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.13. [index] => airIRG2RDT2StatusSuctionTempMetric.{{ $index }} [descr] => Suction [divisor] => 10 ) [17] => Array ( [oid] => rPDU2SensorTempHumidityStatusTable [value] => rPDU2SensorTempHumidityStatusTempC [num_oid] => .1.3.6.1.4.1.318.1.1.26.10.2.2.1.8. [index] => rPDU2SensorTempHumidityStatusTempC.{{ $index }} [descr] => Temperature Probe [divisor] => 10 [skip_values] => Array ( [0] => Array ( [oid] => rPDU2SensorTempHumidityStatusType [op] => = [value] => 4 ) ) ) ) ) Data airIRRP100UnitStatusRackInletTempMetric: Array ( ) Data airIRRP100UnitStatusSupplyAirTempMetric: Array ( ) Data airIRRP100UnitStatusReturnAirTempMetric: Array ( ) Data airIRRP100UnitStatusRackInletTemperature1Metric: Array ( ) Data airIRRP100UnitStatusRackInletTemperature2Metric: Array ( ) Data airIRRP100UnitStatusRackInletTemperature3Metric: Array ( ) Data airIRRP100UnitStatusCompressorDriveHeatSinkTempMetric: Array ( ) Data airIRRP100UnitStatusCompressorDriveControlCardTempMetric: Array ( ) Data airIRRP500UnitStatusSupplyAirTempMetric: Array ( ) Data airIRRP500UnitStatusReturnAirTempMetric: Array ( ) Data airIRRP500UnitStatusRackInletTemperature1Metric: Array ( ) Data airIRRP500UnitStatusRackInletTemperature2Metric: Array ( ) Data airIRRP500UnitStatusRackInletTemperature3Metric: Array ( ) Data airIRG2RDT2StatusRackInletTempMetric: Array ( ) Data airIRG2RDT2StatusSupplyAirTempMetric: Array ( ) Data airIRG2RDT2StatusReturnAirTempMetric: Array ( ) Data airIRG2RDT2StatusSuctionTempMetric: Array ( ) Data rPDU2SensorTempHumidityStatusTable: Array ( ) Array ( [apc] => Array ( [1] => 1 [memSensorsTemperature.0.1] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",22,"snmp"][0m 0.8ms] 1 -> apc memSensorsTemperature.0.1 -> apc Voltage: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.2.2.8.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.3.3.1.3[0m] .*.4.1.3*.*.3 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.8.5.4.3.1.3[0m] .*.4.1.3*.*.3 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.3.2.1.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.1.4.2.1.0[0m] .*.4.1.3*.* No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.12.1.15.0[0m] .*.4.1.3*.1.15.0 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 .1.3.6.1.4.1.318.1.1.26.6.3.1.6[0m] .*.4.1.3*.* No Such Object available on this agent at this OID Dynamic Discovery (voltage): Array ( [data] => Array ( [0] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveVoltage [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.37. [index] => airIRRP100UnitStatusCompressorDriveVoltage.{{ $index }} [descr] => Compressor Drive [divisor] => 10 ) [1] => Array ( [oid] => airIRRP100UnitStatusCompressorDriveDCLinkVoltage [num_oid] => .1.3.6.1.4.1.318.1.1.13.3.3.1.2.2.39. [index] => airIRRP100UnitStatusCompressorDriveDCLinkVoltage.{{ $index }} [descr] => Compressor Drive DC Link [divisor] => 10 ) ) ) Data airIRRP100UnitStatusCompressorDriveVoltage: Array ( ) Data airIRRP100UnitStatusCompressorDriveDCLinkVoltage: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",22,"snmp"][0m 10.52ms] Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",22,"snmp"][0m 0.69ms] Pressure: Dynamic Discovery (pressure): Array ( [data] => Array ( [0] => Array ( [oid] => airIRG2RDT2StatusSuctionPressureMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.19. [index] => airIRG2RDT2StatusSuctionPressureMetric.{{ $index }} [descr] => Suction Pressure ) [1] => Array ( [oid] => airIRG2RDT2StatusDischargePressureMetric [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.21. [index] => airIRG2RDT2StatusDischargePressureMetric.{{ $index }} [descr] => Discharge Pressure ) ) ) Data airIRG2RDT2StatusSuctionPressureMetric: Array ( ) Data airIRG2RDT2StatusDischargePressureMetric: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",22,"snmp"][0m 0.67ms] Cooling: Dynamic Discovery (cooling): Array ( [data] => Array ( [0] => Array ( [oid] => airIRG2RDT2StatusCoolOutput [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.2. [index] => airIRG2RDT2StatusCoolOutput.{{ $index }} [descr] => Output [multiplier] => 100 ) [1] => Array ( [oid] => airIRG2RDT2StatusCoolDemand [num_oid] => .1.3.6.1.4.1.318.1.1.13.4.5.2.1.3. [index] => airIRG2RDT2StatusCoolDemand.{{ $index }} [descr] => Demand [multiplier] => 100 ) ) ) Data airIRG2RDT2StatusCoolOutput: Array ( ) Data airIRG2RDT2StatusCoolDemand: Array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",22,"snmp"][0m 0.68ms] Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",22,"snmp"][0m 0.67ms] Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",22,"snmp"][0m 0.67ms] Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",22,"snmp"][0m 0.68ms] Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",22,"snmp"][0m 0.68ms] Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",22,"snmp"][0m 0.65ms] Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",22,"snmp"][0m 0.66ms] >> Runtime for discovery module 'sensors': 16.6700 seconds with 69032 bytes >> SNMP: [106/16.56s] MySQL: [52/0.07s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc:/opt/librenms/mibs/datadomain udp:HOSTNAME:161 fileSystemSpaceTable[0m] fileSystemSpaceTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '22' AND `storage_type` != 'dsk' [0;33m[][0m 0.46ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '22' [0;33m[][0m 0.31ms] >> Runtime for discovery module 'storage': 0.3400 seconds with 9120 bytes >> SNMP: [3/0.34s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '22' [0;33m[][0m 1.35ms] >> Runtime for discovery module 'hr-device': 0.2600 seconds with 3704 bytes >> SNMP: [2/0.26s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 lldpRemTable[0m] OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[22][0m 0.68ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[22][0m 1.05ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.42ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.2450 seconds with 5048 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress[1] = 0 ipNetToPhysicalPhysAddress[2] = 0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress[2][*] = 0:c:29:25:28:3a ipNetToMediaPhysAddress[2][*] = 0:c:29:f7:5b:99 SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[22,""][0m 1.07ms] SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,1][0m 1.11ms] Warning: Illegal string offset 'ipv4' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60 LOOPBACK: SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[22,2][0m 1.03ms] Warning: Illegal string offset 'ipv4' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60 vmac0: 0:c:29:25:28:3a => 10.0.2.9 0:c:29:f7:5b:99 => 10.0.2.251 SQL[[1;33mDELETE FROM `ipv4_mac` WHERE `port_id` = ? AND `mac_address`=? AND `ipv4_address`=? AND `context_name`=? [0;33m[120,"005056980409","10.0.0.250",""][0m 2.45ms] SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 1.15ms] >> Runtime for discovery module 'arp-table': 0.4030 seconds with 27008 bytes >> SNMP: [0/0.00s] MySQL: [5/0.01s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 bgpLocalAs[0m] "RMON-G-04" No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[22,""][0m 0.54ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[22,""][0m 0.51ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[22][0m 0.63ms] >> Runtime for discovery module 'bgp-peers': 0.0330 seconds with 5624 bytes >> SNMP: [1/0.03s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[22][0m 0.59ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.1900 seconds with 9304 bytes >> SNMP: [2/0.19s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '22' [0;33m[][0m 0.91ms] >> Runtime for discovery module 'ucd-diskio': 0.0940 seconds with 3160 bytes >> SNMP: [1/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 256 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[22][0m 0.77ms] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0450 seconds with 5792 bytes >> SNMP: [1/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ap-count"][0m 0.98ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"clients"][0m 1.59ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"quality"][0m 1.13ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"capacity"][0m 0.73ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"utilization"][0m 0.99ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"rate"][0m 0.75ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ccq"][0m 0.73ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"snr"][0m 0.67ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"ssr"][0m 0.65ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"mse"][0m 0.65ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"rssi"][0m 2.04ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"power"][0m 2.52ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"noise-floor"][0m 0.69ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"errors"][0m 0.66ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"error-ratio"][0m 0.71ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"error-rate"][0m 0.68ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"frequency"][0m 0.66ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[22,"distance"][0m 0.64ms] >> Runtime for discovery module 'wireless': 0.0250 seconds with 139432 bytes >> SNMP: [0/0.00s] MySQL: [18/0.02s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[22][0m 0.49ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[22][0m 0.47ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/apc udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.2920 seconds with 2984 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[22,"poll_mib"][0m 10.21ms] SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[21.991,22][0m 2.65ms] Discovered in 21.991 seconds SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.0.3.193","start":1541189540.1795,"duration":"22.18","devices":1,"poller":"soc-tools"}[0m 2.38ms] ./discovery.php 10.0.3.193 2018-11-02 15:12:42 - 1 devices discovered in 22.18 secs SNMP [135/19.50s]: Get[31/1.99s] Getnext[1/0.03s] Walk[103/17.48s] MySQL [110/0.14s]: Cell[24/0.05s] Row[-1/-0.01s] Rows[68/0.08s] Column[2/0.00s] Update[5/0.00s] Insert[6/0.02s] Delete[6/0.01s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]