- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: 3e9f4b396e504627d8aae5f513c65f536fcf01ee
- Commit Date: 1526058363
- DB Schema: 249
- PHP: 7.2.5
- MySQL: 5.7.21-21
- RRDTool: 1.6.0
- SNMP: NET-SNMP 5.7.2
- ==================================DEBUG!
- Updating os_def.cache... Done
- SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `device_id` = '39' ORDER BY device_id DESC[0m]
- SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '39'[0m]
- acme01 39 acmepacket SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.18','0.20','0.18','39',NOW())[0m]
- SNMP Check response code: 0
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
- Attempting to initialize OS: acmepacket
- Attempting to initialize OS: oracle
- OS initilized as Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
- .*.*.0 = acme01
- .*.*.0 = .*.4.1.9*
- .*.*.0 = Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
- >> Runtime for discovery module 'core': 0.0140 seconds with 1088 bytes
- >> SNMP: [2/0.32s] MySQL: [8/0.00s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
- Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
- .*.4.1.9*
- | Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) | .1.3.6.1.4.1.9148.1.1.2 |
- OS: Acme Packet (acmepacket)
- >> Runtime for discovery module 'os': 0.6350 seconds with 1312 bytes
- >> SNMP: [2/0.64s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifDescr[0m]
- ifDescr.1 = eth0 ETH
- ifDescr.2 = lo0
- ifDescr.5 = M0 GE
- ifDescr.6 = GE
- ifDescr.7 = M1 GE
- ifDescr.8 = GE
- ifDescr.13 = sp0 ETH
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifName[0m]
- ifName.5 = M0
- ifName.6 =
- ifName.7 = M1
- ifName.8 =
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifAlias[0m]
- ifAlias.5 =
- ifAlias.6 =
- ifAlias.7 =
- ifAlias.8 =
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifType[0m]
- ifType.1 = ethernetCsmacd
- ifType.2 = softwareLoopback
- ifType.5 = gigabitEthernet
- ifType.6 = gigabitEthernet
- ifType.7 = gigabitEthernet
- ifType.8 = gigabitEthernet
- ifType.13 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => eth0 ETH
- [ifType] => ethernetCsmacd
- )
- [2] => Array
- (
- [ifDescr] => lo0
- [ifType] => softwareLoopback
- )
- [5] => Array
- (
- [ifDescr] => M0 GE
- [ifName] => M0
- [ifAlias] =>
- [ifType] => gigabitEthernet
- )
- [6] => Array
- (
- [ifDescr] => GE
- [ifName] =>
- [ifAlias] =>
- [ifType] => gigabitEthernet
- )
- [7] => Array
- (
- [ifDescr] => M1 GE
- [ifName] => M1
- [ifAlias] =>
- [ifType] => gigabitEthernet
- )
- [8] => Array
- (
- [ifDescr] => GE
- [ifName] =>
- [ifAlias] =>
- [ifType] => gigabitEthernet
- )
- [13] => Array
- (
- [ifDescr] => sp0 ETH
- [ifType] => ethernetCsmacd
- )
- )
- SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m]
- SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '39' ORDER BY port_id[0m]
- .......
- >> Runtime for discovery module 'ports': 0.0660 seconds with 4216 bytes
- >> SNMP: [4/0.06s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '39'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifStackStatus[0m]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.0180 seconds with 1768 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalEntry[0m]
- entPhysicalDescr.1 = Assy, NetNet4500
- entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
- entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
- entPhysicalDescr.4 = Assy, 4-fan unit
- entPhysicalDescr.5 = PHY Slot
- entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
- entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
- entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
- entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
- entPhysicalDescr.10 = Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
- entPhysicalDescr.11 = Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
- entPhysicalDescr.12 = Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
- entPhysicalDescr.13 = Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
- entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
- entPhysicalDescr.19 = TLS Hardware Accelerator
- entPhysicalVendorType.1 = enterprises.9*.3.2.5
- entPhysicalVendorType.2 = enterprises.9*.5.3
- entPhysicalVendorType.3 = enterprises.9*.5.3
- entPhysicalVendorType.4 = enterprises.9*.6.3
- entPhysicalVendorType.5 = enterprises.9*.4.2.2
- entPhysicalVendorType.6 = enterprises.9*.8.2.12
- entPhysicalVendorType.7 = enterprises.9*.9.3
- entPhysicalVendorType.8 = enterprises.9*.9.3
- entPhysicalVendorType.9 = enterprises.9*.9.3
- entPhysicalVendorType.10 = enterprises.9*.9.2
- entPhysicalVendorType.11 = enterprises.9*.9.2
- entPhysicalVendorType.12 = enterprises.9*.9.2
- entPhysicalVendorType.13 = enterprises.9*.9.2
- entPhysicalVendorType.18 = enterprises.9*.8.4.7
- entPhysicalVendorType.19 = enterprises.9*.8.8.6
- entPhysicalContainedIn.1 = 0
- entPhysicalContainedIn.2 = 1
- entPhysicalContainedIn.3 = 1
- entPhysicalContainedIn.4 = 1
- entPhysicalContainedIn.5 = 1
- entPhysicalContainedIn.6 = 5
- entPhysicalContainedIn.7 = 6
- entPhysicalContainedIn.8 = 6
- entPhysicalContainedIn.9 = 6
- entPhysicalContainedIn.10 = 6
- entPhysicalContainedIn.11 = 6
- entPhysicalContainedIn.12 = 6
- entPhysicalContainedIn.13 = 6
- entPhysicalContainedIn.18 = 1
- entPhysicalContainedIn.19 = 1
- entPhysicalClass.1 = chassis
- entPhysicalClass.2 = powerSupply
- entPhysicalClass.3 = powerSupply
- entPhysicalClass.4 = fan
- entPhysicalClass.5 = container
- entPhysicalClass.6 = module
- entPhysicalClass.7 = port
- entPhysicalClass.8 = port
- entPhysicalClass.9 = port
- entPhysicalClass.10 = port
- entPhysicalClass.11 = port
- entPhysicalClass.12 = port
- entPhysicalClass.13 = port
- entPhysicalClass.18 = module
- entPhysicalClass.19 = module
- entPhysicalParentRelPos.1 = 0
- entPhysicalParentRelPos.2 = 1
- entPhysicalParentRelPos.3 = 2
- entPhysicalParentRelPos.4 = 3
- entPhysicalParentRelPos.5 = 4
- entPhysicalParentRelPos.6 = 1
- entPhysicalParentRelPos.7 = 1
- entPhysicalParentRelPos.8 = 2
- entPhysicalParentRelPos.9 = 3
- entPhysicalParentRelPos.10 = 1
- entPhysicalParentRelPos.11 = 2
- entPhysicalParentRelPos.12 = 3
- entPhysicalParentRelPos.13 = 4
- entPhysicalParentRelPos.18 = 5
- entPhysicalParentRelPos.19 = 7
- entPhysicalName.1 = Main Board
- entPhysicalName.2 = Power Supply A
- entPhysicalName.3 = Power Supply B
- entPhysicalName.4 = 4-Fan unit
- entPhysicalName.5 = PHY Slot
- entPhysicalName.6 = Quad port GiGE SFP PHY
- entPhysicalName.7 = Mgmt0
- entPhysicalName.8 = Mgmt1
- entPhysicalName.9 = Mgmt2
- entPhysicalName.10 = M0
- entPhysicalName.11 = M1
- entPhysicalName.12 =
- entPhysicalName.13 =
- entPhysicalName.18 = Host CPU Processor
- entPhysicalName.19 = BCM5823
- entPhysicalHardwareRev.1 = 5.10
- entPhysicalHardwareRev.2 =
- entPhysicalHardwareRev.3 =
- entPhysicalHardwareRev.4 =
- entPhysicalHardwareRev.5 =
- entPhysicalHardwareRev.6 = 4.11
- entPhysicalHardwareRev.7 =
- entPhysicalHardwareRev.8 =
- entPhysicalHardwareRev.9 =
- entPhysicalHardwareRev.10 =
- entPhysicalHardwareRev.11 =
- entPhysicalHardwareRev.12 =
- entPhysicalHardwareRev.13 =
- entPhysicalHardwareRev.18 =
- entPhysicalHardwareRev.19 = 1
- entPhysicalFirmwareRev.1 =
- entPhysicalFirmwareRev.2 =
- entPhysicalFirmwareRev.3 =
- entPhysicalFirmwareRev.4 =
- entPhysicalFirmwareRev.5 =
- entPhysicalFirmwareRev.6 =
- entPhysicalFirmwareRev.7 =
- entPhysicalFirmwareRev.8 =
- entPhysicalFirmwareRev.9 =
- entPhysicalFirmwareRev.10 =
- entPhysicalFirmwareRev.11 =
- entPhysicalFirmwareRev.12 =
- entPhysicalFirmwareRev.13 =
- entPhysicalFirmwareRev.18 =
- entPhysicalFirmwareRev.19 =
- entPhysicalSoftwareRev.1 =
- entPhysicalSoftwareRev.2 =
- entPhysicalSoftwareRev.3 =
- entPhysicalSoftwareRev.4 =
- entPhysicalSoftwareRev.5 =
- entPhysicalSoftwareRev.6 =
- entPhysicalSoftwareRev.7 =
- entPhysicalSoftwareRev.8 =
- entPhysicalSoftwareRev.9 =
- entPhysicalSoftwareRev.10 =
- entPhysicalSoftwareRev.11 =
- entPhysicalSoftwareRev.12 =
- entPhysicalSoftwareRev.13 =
- entPhysicalSoftwareRev.18 =
- entPhysicalSoftwareRev.19 =
- entPhysicalSerialNum.1 =
- entPhysicalSerialNum.2 =
- entPhysicalSerialNum.3 =
- entPhysicalSerialNum.4 =
- entPhysicalSerialNum.5 =
- entPhysicalSerialNum.6 =
- entPhysicalSerialNum.7 =
- entPhysicalSerialNum.8 =
- entPhysicalSerialNum.9 =
- entPhysicalSerialNum.10 =
- entPhysicalSerialNum.11 =
- entPhysicalSerialNum.12 =
- entPhysicalSerialNum.13 =
- entPhysicalSerialNum.18 =
- entPhysicalSerialNum.19 =
- entPhysicalMfgName.1 = Unknown manufacturer
- entPhysicalMfgName.2 =
- entPhysicalMfgName.3 =
- entPhysicalMfgName.4 =
- entPhysicalMfgName.5 =
- entPhysicalMfgName.6 = Benchmark Electronics
- entPhysicalMfgName.7 =
- entPhysicalMfgName.8 =
- entPhysicalMfgName.9 =
- entPhysicalMfgName.10 =
- entPhysicalMfgName.11 =
- entPhysicalMfgName.12 =
- entPhysicalMfgName.13 =
- entPhysicalMfgName.18 =
- entPhysicalMfgName.19 = BROADCOM
- entPhysicalModelName.1 = 002-0610-50
- entPhysicalModelName.2 =
- entPhysicalModelName.3 =
- entPhysicalModelName.4 =
- entPhysicalModelName.5 =
- entPhysicalModelName.6 = 002-0613-58
- entPhysicalModelName.7 =
- entPhysicalModelName.8 =
- entPhysicalModelName.9 =
- entPhysicalModelName.10 =
- entPhysicalModelName.11 =
- entPhysicalModelName.12 =
- entPhysicalModelName.13 =
- entPhysicalModelName.18 =
- entPhysicalModelName.19 = BCM5823
- entPhysicalAlias.1 =
- entPhysicalAlias.2 =
- entPhysicalAlias.3 =
- entPhysicalAlias.4 =
- entPhysicalAlias.5 =
- entPhysicalAlias.6 =
- entPhysicalAlias.7 =
- entPhysicalAlias.8 =
- entPhysicalAlias.9 =
- entPhysicalAlias.10 =
- entPhysicalAlias.11 =
- entPhysicalAlias.12 =
- entPhysicalAlias.13 =
- entPhysicalAlias.18 =
- entPhysicalAlias.19 =
- entPhysicalAssetID.1 =
- entPhysicalAssetID.2 =
- entPhysicalAssetID.3 =
- entPhysicalAssetID.4 =
- entPhysicalAssetID.5 =
- entPhysicalAssetID.6 =
- entPhysicalAssetID.7 =
- entPhysicalAssetID.8 =
- entPhysicalAssetID.9 =
- entPhysicalAssetID.10 =
- entPhysicalAssetID.11 =
- entPhysicalAssetID.12 =
- entPhysicalAssetID.13 =
- entPhysicalAssetID.18 =
- entPhysicalAssetID.19 =
- entPhysicalIsFRU.1 = false
- entPhysicalIsFRU.2 = true
- entPhysicalIsFRU.3 = true
- entPhysicalIsFRU.4 = true
- entPhysicalIsFRU.5 = false
- entPhysicalIsFRU.6 = true
- entPhysicalIsFRU.7 = false
- entPhysicalIsFRU.8 = false
- entPhysicalIsFRU.9 = false
- entPhysicalIsFRU.10 = true
- entPhysicalIsFRU.11 = true
- entPhysicalIsFRU.12 = true
- entPhysicalIsFRU.13 = true
- entPhysicalIsFRU.18 = false
- entPhysicalIsFRU.19 = true
- entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
- entAliasMappingIdentifier = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '1'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='Assy, NetNet4500',`entPhysicalClass` ='chassis',`entPhysicalName` ='Main Board',`entPhysicalModelName` ='002-0610-50',`entPhysicalSerialNum` ='151330035903',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Unknown manufacturer',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='enterprises.9148.6.1.1.3.2.5',`entPhysicalHardwareRev` ='5.10',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='1'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '2'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply A',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='2'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '3'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='3',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply B',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='3'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '4'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='4',`entPhysicalDescr` ='Assy, 4-fan unit',`entPhysicalClass` ='fan',`entPhysicalName` ='4-Fan unit',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.6.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='4'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '5'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='5',`entPhysicalDescr` ='PHY Slot',`entPhysicalClass` ='container',`entPhysicalName` ='PHY Slot',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.4.2.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='5'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '6'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='6',`entPhysicalDescr` ='Assy, 4 Port SFP with QOS and IPSec',`entPhysicalClass` ='module',`entPhysicalName` ='Quad port GiGE SFP PHY',`entPhysicalModelName` ='002-0613-58',`entPhysicalSerialNum` ='091128054782',`entPhysicalContainedIn` ='5',`entPhysicalMfgName` ='Benchmark Electronics',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.2.12',`entPhysicalHardwareRev` ='4.11',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='6'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '7'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='7',`entPhysicalDescr` ='Management Port 0 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='7'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '8'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='8',`entPhysicalDescr` ='Management Port 1 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='8'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '9'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='9',`entPhysicalDescr` ='Management Port 2 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt2',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='9'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '10'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='10',`entPhysicalDescr` ='Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='M0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='10'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '11'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='11',`entPhysicalDescr` ='Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='M1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='11'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '12'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='12',`entPhysicalDescr` ='Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='12'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '13'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='13',`entPhysicalDescr` ='Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='13'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '18'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='18',`entPhysicalDescr` ='Intel Pentium Core 2 Duo Module',`entPhysicalClass` ='module',`entPhysicalName` ='Host CPU Processor',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='5',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.4.7',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='18'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '19'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='19',`entPhysicalDescr` ='TLS Hardware Accelerator',`entPhysicalClass` ='module',`entPhysicalName` ='BCM5823',`entPhysicalModelName` ='BCM5823',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='BROADCOM',`entPhysicalParentRelPos` ='7',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.8.6',`entPhysicalHardwareRev` ='1',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='19'[0m]
- .
- SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '39'[0m]
- >> Runtime for discovery module 'entity-physical': 0.1700 seconds with 9744 bytes
- >> SNMP: [1/0.14s] MySQL: [31/0.01s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global- OS- Device- Module [ entity-state ] disabled on host.
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- Caching data: sensors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonCpuCoreTable[0m]
- apEnvMonCpuCoreTable = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPhyCardStatusTable[0m]
- apEnvMonPhyCardStatusType.1 = 0
- apEnvMonPhyCardStatusDescr.1 = "Phy"
- apEnvMonPhyCardState.1 = 2
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPowerSupplyStatusTable[0m]
- apEnvMonPowerSupplyStatusType.1 = 1
- apEnvMonPowerSupplyStatusType.2 = 0
- apEnvMonPowerSupplyStatusDescr.1 = "Power Supply A"
- apEnvMonPowerSupplyStatusDescr.2 = "Power Supply B"
- apEnvMonPowerSupplyState.1 = 2
- apEnvMonPowerSupplyState.2 = 2
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonFanStatusTable[0m]
- apEnvMonFanStatusType.1 = 11
- apEnvMonFanStatusType.2 = 12
- apEnvMonFanStatusType.3 = 13
- apEnvMonFanStatusType.4 = 14
- apEnvMonFanStatusDescr.1 = "Fan 1 Speed"
- apEnvMonFanStatusDescr.2 = "Fan 2 Speed"
- apEnvMonFanStatusDescr.3 = "Fan 3 Speed"
- apEnvMonFanStatusDescr.4 = "Fan 4 Speed"
- apEnvMonFanStatusValue.1 = 100
- apEnvMonFanStatusValue.2 = 100
- apEnvMonFanStatusValue.3 = 100
- apEnvMonFanStatusValue.4 = 100
- apEnvMonFanState.1 = 2
- apEnvMonFanState.2 = 2
- apEnvMonFanState.3 = 2
- apEnvMonFanState.4 = 2
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonTemperatureStatusTable[0m]
- apEnvMonTemperatureStatusType.1 = 6
- apEnvMonTemperatureStatusType.2 = 5
- apEnvMonTemperatureStatusType.3 = 4
- apEnvMonTemperatureStatusType.4 = 7
- apEnvMonTemperatureStatusDescr.1 = "CPU Temperature (degrees Celsius)"
- apEnvMonTemperatureStatusDescr.2 = "Main Board Temperature 0 (degrees Celcius)"
- apEnvMonTemperatureStatusDescr.3 = "Main Board Temperature 1 (degrees Celcius)"
- apEnvMonTemperatureStatusDescr.4 = "PHY Temperature 0 (degrees Celcius)"
- apEnvMonTemperatureStatusValue.1 = 45
- apEnvMonTemperatureStatusValue.2 = 31
- apEnvMonTemperatureStatusValue.3 = 28
- apEnvMonTemperatureStatusValue.4 = 43
- apEnvMonTemperatureState.1 = 2
- apEnvMonTemperatureState.2 = 2
- apEnvMonTemperatureState.3 = 2
- apEnvMonTemperatureState.4 = 2
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonVoltageStatusTable[0m]
- apEnvMonVoltageStatusType.1 = 8
- apEnvMonVoltageStatusType.2 = 12
- apEnvMonVoltageStatusType.3 = 13
- apEnvMonVoltageStatusType.4 = 1
- apEnvMonVoltageStatusType.5 = 2
- apEnvMonVoltageStatusType.6 = 3
- apEnvMonVoltageStatusType.7 = 15
- apEnvMonVoltageStatusDescr.1 = "1.2V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.2 = "1.5V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.3 = "1.8V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.4 = "2.5V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.5 = "3.3V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.6 = "5.0V voltage (millivolts)"
- apEnvMonVoltageStatusDescr.7 = "3.3V Aux voltage (millivolts)"
- apEnvMonVoltageStatusValue.1 = 1205
- apEnvMonVoltageStatusValue.2 = 1493
- apEnvMonVoltageStatusValue.3 = 1794
- apEnvMonVoltageStatusValue.4 = 2483
- apEnvMonVoltageStatusValue.5 = 3288
- apEnvMonVoltageStatusValue.6 = 5058
- apEnvMonVoltageStatusValue.7 = 3263
- apEnvMonVoltageState.1 = 2
- apEnvMonVoltageState.2 = 2
- apEnvMonVoltageState.3 = 2
- apEnvMonVoltageState.4 = 2
- apEnvMonVoltageState.5 = 2
- apEnvMonVoltageState.6 = 2
- apEnvMonVoltageState.7 = 2
- processors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apSysCPUUtil[0m]
- apSysCPUUtil.0 = 35
- YAML Discovery Data: Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apSysCPUUtil
- [num_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1
- [type] => acmepacket
- )
- )
- )
- Data apSysCPUUtil: Array
- (
- [0] => Array
- (
- [apSysCPUUtil] => 35
- )
- )
- Discovered LibreNMS\Device\Processor Array
- (
- [processor_id] =>
- [entPhysicalIndex] => 0
- [hrDeviceIndex] => 0
- [device_id] => 39
- [processor_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1
- [processor_index] => 0
- [processor_type] => acmepacket
- [processor_usage] => 35
- [processor_descr] => Processor
- [processor_precision] => 1
- [processor_perc_warn] => 75
- )
- SQL[[0;33mSELECT * FROM `processors` WHERE device_id='39' AND processor_index='0' AND processor_type='acmepacket'[0m]
- .SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`='39' AND `processor_id` NOT IN ('761')[0m]
- SQL[[0;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'processors': 0.1460 seconds with 180008 bytes
- >> SNMP: [7/0.14s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '39' AND `mempool_type` = 'cemp'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '39'[0m]
- >> Runtime for discovery module 'mempools': 0.0700 seconds with 41872 bytes
- >> SNMP: [3/0.07s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '39' [0m]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2640 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
- Modules status: Global- OS- Device Module [ vrf ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntIfIndex[0m]
- ipAdEntIfIndex.* 5
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
- *
- SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '39' AND `ifIndex` = '5'[0m]
- SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '39' AND `ifIndex` = '5'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
- SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
- sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542' [0m]
- SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542'[0m]
- .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
- *
- >> Runtime for discovery module 'ipv4-addresses': 3.1630 seconds with 36792 bytes
- >> SNMP: [128/2.38s] MySQL: [890/0.78s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
- ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '39' OR `ports`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'ipv6-addresses': 0.0330 seconds with 1376 bytes
- >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS- Device Module [ route ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalDescr[0m]
- entPhysicalDescr.1 = Assy, NetNet4500
- entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
- entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
- entPhysicalDescr.4 = Assy, 4-fan unit
- entPhysicalDescr.5 = PHY Slot
- entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
- entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
- entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
- entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
- entPhysicalDescr.10 = Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
- entPhysicalDescr.11 = Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
- entPhysicalDescr.12 = Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
- entPhysicalDescr.13 = Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
- entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
- entPhysicalDescr.19 = TLS Hardware Accelerator
- entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalName[0m]
- entPhysicalName.1 = Main Board
- entPhysicalName.2 = Power Supply A
- entPhysicalName.3 = Power Supply B
- entPhysicalName.4 = 4-Fan unit
- entPhysicalName.5 = PHY Slot
- entPhysicalName.6 = Quad port GiGE SFP PHY
- entPhysicalName.7 = Mgmt0
- entPhysicalName.8 = Mgmt1
- entPhysicalName.9 = Mgmt2
- entPhysicalName.10 = M0
- entPhysicalName.11 = M1
- entPhysicalName.12 =
- entPhysicalName.13 =
- entPhysicalName.18 = Host CPU Processor
- entPhysicalName.19 = BCM5823
- entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorType[0m]
- entPhySensorType = No Such Object available on this agent at this OID
- entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorScale[0m]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorPrecision[0m]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorValue[0m]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'ipmi_hostname' [0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
- Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Fanspeed: Dynamic Discovery (fanspeed): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apEnvMonFanStatusTable
- [value] => apEnvMonFanStatusValue
- [num_oid] => .
- [descr] => apEnvMonFanStatusDescr
- [index] => apEnvMonFanStatusValue.{{ $index }}
- )
- )
- )
- Data apEnvMonFanStatusTable: Array
- (
- [1] => Array
- (
- [apEnvMonFanStatusType] => 11
- [apEnvMonFanStatusDescr] => Fan 1 Speed
- [apEnvMonFanStatusValue] => 100
- [apEnvMonFanState] => 2
- )
- [2] => Array
- (
- [apEnvMonFanStatusType] => 12
- [apEnvMonFanStatusDescr] => Fan 2 Speed
- [apEnvMonFanStatusValue] => 100
- [apEnvMonFanState] => 2
- )
- [3] => Array
- (
- [apEnvMonFanStatusType] => 13
- [apEnvMonFanStatusDescr] => Fan 3 Speed
- [apEnvMonFanStatusValue] => 100
- [apEnvMonFanState] => 2
- )
- [4] => Array
- (
- [apEnvMonFanStatusType] => 14
- [apEnvMonFanStatusDescr] => Fan 4 Speed
- [apEnvMonFanStatusValue] => 100
- [apEnvMonFanState] => 2
- )
- )
- Final sensor value: 100
- Cur 100, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1, apEnvMonFanStatusValue.1, acmepacket, Fan 1 Speed, snmp, 1, 1, , 100
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.1','apEnvMonFanStatusValue.1','acmepacket','Fan 1 Speed','1','1','180','80','100')[0m]
- ( 1045 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1045','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.1 Fan 1 Speed','')[0m]
- Final sensor value: 100
- Cur 100, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .2, apEnvMonFanStatusValue.2, acmepacket, Fan 2 Speed, snmp, 1, 1, , 100
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.2'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.2','apEnvMonFanStatusValue.2','acmepacket','Fan 2 Speed','1','1','180','80','100')[0m]
- ( 1046 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1046','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.2 Fan 2 Speed','')[0m]
- Final sensor value: 100
- Cur 100, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .3, apEnvMonFanStatusValue.3, acmepacket, Fan 3 Speed, snmp, 1, 1, , 100
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.3'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.3','apEnvMonFanStatusValue.3','acmepacket','Fan 3 Speed','1','1','180','80','100')[0m]
- ( 1047 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1047','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.3 Fan 3 Speed','')[0m]
- Final sensor value: 100
- Cur 100, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .4, apEnvMonFanStatusValue.4, acmepacket, Fan 4 Speed, snmp, 1, 1, , 100
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.4'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.4','apEnvMonFanStatusValue.4','acmepacket','Fan 4 Speed','1','1','180','80','100')[0m]
- ( 1048 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1048','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.4 Fan 4 Speed','')[0m]
- Array
- (
- [acmepacket] => Array
- (
- [apEnvMonFanStatusValue.1] => 1
- [apEnvMonFanStatusValue.2] => 1
- [apEnvMonFanStatusValue.3] => 1
- [apEnvMonFanStatusValue.4] => 1
- )
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- apEnvMonFanStatusValue.1 -> acmepacket
- apEnvMonFanStatusValue.2 -> acmepacket
- apEnvMonFanStatusValue.3 -> acmepacket
- apEnvMonFanStatusValue.4 -> acmepacket
- Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Load: Dynamic Discovery (load): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apEnvMonCpuCoreTable
- [value] => apEnvMonCpuCoreUsage
- [num_oid] => .
- [descr] => apEnvMonCpuCoreDescr
- )
- )
- )
- Data apEnvMonCpuCoreTable: Array
- (
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- State: Dynamic Discovery (state): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apEnvMonPhyCardStatusTable
- [value] => apEnvMonPhyCardState
- [num_oid] => .
- [descr] => apEnvMonPhyCardStatusDescr
- )
- [1] => Array
- (
- [oid] => apEnvMonPowerSupplyStatusTable
- [value] => apEnvMonPowerSupplyState
- [num_oid] => .
- [descr] => apEnvMonPowerSupplyStatusDescr
- [index] => apEnvMonPowerSupplyStatusIndex.{{ $index }}
- )
- )
- )
- Data apEnvMonPhyCardStatusTable: Array
- (
- [1] => Array
- (
- [apEnvMonPhyCardStatusType] => 0
- [apEnvMonPhyCardStatusDescr] => Phy
- [apEnvMonPhyCardState] => 2
- )
- )
- Final sensor value: 2
- Cur 2, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPhyCardStatusTable' LIMIT 1[0m]
- SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '21'[0m]
- Discover sensor: .1, 1, apEnvMonPhyCardStatusTable, Phy, snmp, 1, 1, , 2
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.1','1','apEnvMonPhyCardStatusTable','Phy','1','1','2')[0m]
- ( 1049 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1049','sensor',NOW(),'3','Sensor Added: state apEnvMonPhyCardStatusTable 1 Phy','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPhyCardStatusTable'[0m]
- SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1049','21')[0m]
- Data apEnvMonPowerSupplyStatusTable: Array
- (
- [1] => Array
- (
- [apEnvMonPowerSupplyStatusType] => 1
- [apEnvMonPowerSupplyStatusDescr] => Power Supply A
- [apEnvMonPowerSupplyState] => 2
- )
- [2] => Array
- (
- [apEnvMonPowerSupplyStatusType] => 0
- [apEnvMonPowerSupplyStatusDescr] => Power Supply B
- [apEnvMonPowerSupplyState] => 2
- )
- )
- Final sensor value: 2
- Cur 2, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m]
- SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m]
- Discover sensor: .1, apEnvMonPowerSupplyStatusIndex.1, apEnvMonPowerSupplyStatusTable, Power Supply A, snmp, 1, 1, , 2
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.1','apEnvMonPowerSupplyStatusIndex.1','apEnvMonPowerSupplyStatusTable','Power Supply A','1','1','2')[0m]
- ( 1050 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1050','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.1 Power Supply A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m]
- SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1050','22')[0m]
- Final sensor value: 2
- Cur 2, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m]
- SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m]
- Discover sensor: .2, apEnvMonPowerSupplyStatusIndex.2, apEnvMonPowerSupplyStatusTable, Power Supply B, snmp, 1, 1, , 2
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.2','apEnvMonPowerSupplyStatusIndex.2','apEnvMonPowerSupplyStatusTable','Power Supply B','1','1','2')[0m]
- ( 1051 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1051','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.2 Power Supply B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m]
- SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1051','22')[0m]
- Array
- (
- [apEnvMonPhyCardStatusTable] => Array
- (
- [1] => 1
- )
- [apEnvMonPowerSupplyStatusTable] => Array
- (
- [apEnvMonPowerSupplyStatusIndex.1] => 1
- [apEnvMonPowerSupplyStatusIndex.2] => 1
- )
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- 1 -> apEnvMonPhyCardStatusTable
- apEnvMonPowerSupplyStatusIndex.1 -> apEnvMonPowerSupplyStatusTable
- apEnvMonPowerSupplyStatusIndex.2 -> apEnvMonPowerSupplyStatusTable
- Temperature: Dynamic Discovery (temperature): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apEnvMonTemperatureStatusTable
- [value] => apEnvMonTemperatureStatusValue
- [num_oid] => .
- [descr] => apEnvMonTemperatureStatusDescr
- [index] => apEnvMonTemperatureStatusIndex.{{ $index }}
- )
- )
- )
- Data apEnvMonTemperatureStatusTable: Array
- (
- [1] => Array
- (
- [apEnvMonTemperatureStatusType] => 6
- [apEnvMonTemperatureStatusDescr] => CPU Temperature (degrees Celsius)
- [apEnvMonTemperatureStatusValue] => 45
- [apEnvMonTemperatureState] => 2
- )
- [2] => Array
- (
- [apEnvMonTemperatureStatusType] => 5
- [apEnvMonTemperatureStatusDescr] => Main Board Temperature 0 (degrees Celcius)
- [apEnvMonTemperatureStatusValue] => 31
- [apEnvMonTemperatureState] => 2
- )
- [3] => Array
- (
- [apEnvMonTemperatureStatusType] => 4
- [apEnvMonTemperatureStatusDescr] => Main Board Temperature 1 (degrees Celcius)
- [apEnvMonTemperatureStatusValue] => 28
- [apEnvMonTemperatureState] => 2
- )
- [4] => Array
- (
- [apEnvMonTemperatureStatusType] => 7
- [apEnvMonTemperatureStatusDescr] => PHY Temperature 0 (degrees Celcius)
- [apEnvMonTemperatureStatusValue] => 43
- [apEnvMonTemperatureState] => 2
- )
- )
- Final sensor value: 45
- Cur 45, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1, apEnvMonTemperatureStatusIndex.1, acmepacket, CPU Temperature (degrees Celsius), snmp, 1, 1, , 45
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.1','apEnvMonTemperatureStatusIndex.1','acmepacket','CPU Temperature (degrees Celsius)','1','1','65','35','45')[0m]
- ( 1052 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1052','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.1 CPU Temperature (degrees Celsius)','')[0m]
- Final sensor value: 31
- Cur 31, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .2, apEnvMonTemperatureStatusIndex.2, acmepacket, Main Board Temperature 0 (degrees Celcius), snmp, 1, 1, , 31
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.2'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.2','apEnvMonTemperatureStatusIndex.2','acmepacket','Main Board Temperature 0 (degrees Celcius)','1','1','51','21','31')[0m]
- ( 1053 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1053','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.2 Main Board Temperature 0 (degrees Celcius)','')[0m]
- Final sensor value: 28
- Cur 28, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .3, apEnvMonTemperatureStatusIndex.3, acmepacket, Main Board Temperature 1 (degrees Celcius), snmp, 1, 1, , 28
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.3'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.3','apEnvMonTemperatureStatusIndex.3','acmepacket','Main Board Temperature 1 (degrees Celcius)','1','1','48','18','28')[0m]
- ( 1054 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1054','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.3 Main Board Temperature 1 (degrees Celcius)','')[0m]
- Final sensor value: 43
- Cur 43, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .4, apEnvMonTemperatureStatusIndex.4, acmepacket, PHY Temperature 0 (degrees Celcius), snmp, 1, 1, , 43
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.4'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.4','apEnvMonTemperatureStatusIndex.4','acmepacket','PHY Temperature 0 (degrees Celcius)','1','1','63','33','43')[0m]
- ( 1055 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1055','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.4 PHY Temperature 0 (degrees Celcius)','')[0m]
- Array
- (
- [acmepacket] => Array
- (
- [apEnvMonTemperatureStatusIndex.1] => 1
- [apEnvMonTemperatureStatusIndex.2] => 1
- [apEnvMonTemperatureStatusIndex.3] => 1
- [apEnvMonTemperatureStatusIndex.4] => 1
- )
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- apEnvMonTemperatureStatusIndex.1 -> acmepacket
- apEnvMonTemperatureStatusIndex.2 -> acmepacket
- apEnvMonTemperatureStatusIndex.3 -> acmepacket
- apEnvMonTemperatureStatusIndex.4 -> acmepacket
- Voltage: Dynamic Discovery (voltage): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => apEnvMonVoltageStatusTable
- [value] => apEnvMonVoltageStatusValue
- [num_oid] => .
- [descr] => apEnvMonVoltageStatusDescr
- [divisor] => 1000
- [index] => apEnvMonVoltageStatusIndex.{{ $index }}
- )
- )
- )
- Data apEnvMonVoltageStatusTable: Array
- (
- [1] => Array
- (
- [apEnvMonVoltageStatusType] => 8
- [apEnvMonVoltageStatusDescr] => 1.2V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 1205
- [apEnvMonVoltageState] => 2
- )
- [2] => Array
- (
- [apEnvMonVoltageStatusType] => 12
- [apEnvMonVoltageStatusDescr] => 1.5V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 1493
- [apEnvMonVoltageState] => 2
- )
- [3] => Array
- (
- [apEnvMonVoltageStatusType] => 13
- [apEnvMonVoltageStatusDescr] => 1.8V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 1794
- [apEnvMonVoltageState] => 2
- )
- [4] => Array
- (
- [apEnvMonVoltageStatusType] => 1
- [apEnvMonVoltageStatusDescr] => 2.5V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 2483
- [apEnvMonVoltageState] => 2
- )
- [5] => Array
- (
- [apEnvMonVoltageStatusType] => 2
- [apEnvMonVoltageStatusDescr] => 3.3V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 3288
- [apEnvMonVoltageState] => 2
- )
- [6] => Array
- (
- [apEnvMonVoltageStatusType] => 3
- [apEnvMonVoltageStatusDescr] => 5.0V voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 5058
- [apEnvMonVoltageState] => 2
- )
- [7] => Array
- (
- [apEnvMonVoltageStatusType] => 15
- [apEnvMonVoltageStatusDescr] => 3.3V Aux voltage (millivolts)
- [apEnvMonVoltageStatusValue] => 3263
- [apEnvMonVoltageState] => 2
- )
- )
- Final sensor value: 1205
- Cur 1205, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1, apEnvMonVoltageStatusIndex.1, acmepacket, 1.2V voltage (millivolts), snmp, 1000, 1, , 1.205
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.1','apEnvMonVoltageStatusIndex.1','acmepacket','1.2V voltage (millivolts)','1000','1','1.38575','1.02425','1.205')[0m]
- ( 1056 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1056','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.1 1.2V voltage (millivolts)','')[0m]
- Final sensor value: 1493
- Cur 1493, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .2, apEnvMonVoltageStatusIndex.2, acmepacket, 1.5V voltage (millivolts), snmp, 1000, 1, , 1.493
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.2'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.2','apEnvMonVoltageStatusIndex.2','acmepacket','1.5V voltage (millivolts)','1000','1','1.71695','1.26905','1.493')[0m]
- ( 1057 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1057','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.2 1.5V voltage (millivolts)','')[0m]
- Final sensor value: 1794
- Cur 1794, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .3, apEnvMonVoltageStatusIndex.3, acmepacket, 1.8V voltage (millivolts), snmp, 1000, 1, , 1.794
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.3'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.3','apEnvMonVoltageStatusIndex.3','acmepacket','1.8V voltage (millivolts)','1000','1','2.0631','1.5249','1.794')[0m]
- ( 1058 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1058','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.3 1.8V voltage (millivolts)','')[0m]
- Final sensor value: 2483
- Cur 2483, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .4, apEnvMonVoltageStatusIndex.4, acmepacket, 2.5V voltage (millivolts), snmp, 1000, 1, , 2.483
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.4'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.4','apEnvMonVoltageStatusIndex.4','acmepacket','2.5V voltage (millivolts)','1000','1','2.85545','2.11055','2.483')[0m]
- ( 1059 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1059','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.4 2.5V voltage (millivolts)','')[0m]
- Final sensor value: 3288
- Cur 3288, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .5, apEnvMonVoltageStatusIndex.5, acmepacket, 3.3V voltage (millivolts), snmp, 1000, 1, , 3.288
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.5'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.5','apEnvMonVoltageStatusIndex.5','acmepacket','3.3V voltage (millivolts)','1000','1','3.7812','2.7948','3.288')[0m]
- ( 1060 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1060','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.5 3.3V voltage (millivolts)','')[0m]
- Final sensor value: 5058
- Cur 5058, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .6, apEnvMonVoltageStatusIndex.6, acmepacket, 5.0V voltage (millivolts), snmp, 1000, 1, , 5.058
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.6'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.6','apEnvMonVoltageStatusIndex.6','acmepacket','5.0V voltage (millivolts)','1000','1','5.8167','4.2993','5.058')[0m]
- ( 1061 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1061','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.6 5.0V voltage (millivolts)','')[0m]
- Final sensor value: 3263
- Cur 3263, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .7, apEnvMonVoltageStatusIndex.7, acmepacket, 3.3V Aux voltage (millivolts), snmp, 1000, 1, , 3.263
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.7'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.7','apEnvMonVoltageStatusIndex.7','acmepacket','3.3V Aux voltage (millivolts)','1000','1','3.75245','2.77355','3.263')[0m]
- ( 1062 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1062','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.7 3.3V Aux voltage (millivolts)','')[0m]
- Array
- (
- [acmepacket] => Array
- (
- [apEnvMonVoltageStatusIndex.1] => 1
- [apEnvMonVoltageStatusIndex.2] => 1
- [apEnvMonVoltageStatusIndex.3] => 1
- [apEnvMonVoltageStatusIndex.4] => 1
- [apEnvMonVoltageStatusIndex.5] => 1
- [apEnvMonVoltageStatusIndex.6] => 1
- [apEnvMonVoltageStatusIndex.7] => 1
- )
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- apEnvMonVoltageStatusIndex.1 -> acmepacket
- apEnvMonVoltageStatusIndex.2 -> acmepacket
- apEnvMonVoltageStatusIndex.3 -> acmepacket
- apEnvMonVoltageStatusIndex.4 -> acmepacket
- apEnvMonVoltageStatusIndex.5 -> acmepacket
- apEnvMonVoltageStatusIndex.6 -> acmepacket
- apEnvMonVoltageStatusIndex.7 -> acmepacket
- Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Delay: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Quality_factor: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Chromatic_dispersion: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Ber: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Eer: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- Waterflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
- >> Runtime for discovery module 'sensors': 0.1460 seconds with 32000 bytes
- >> SNMP: [6/0.11s] MySQL: [97/0.03s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dskTable[0m]
- dskTable = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '39' AND `storage_type` != 'dsk'[0m]
- SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '39'[0m]
- >> Runtime for discovery module 'storage': 0.0380 seconds with 8376 bytes
- >> SNMP: [2/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrDeviceEntry[0m]
- hrDeviceEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrProcessorEntry[0m]
- hrProcessorEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '39'[0m]
- >> Runtime for discovery module 'hr-device': 0.0330 seconds with 3704 bytes
- >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 cdpCache[0m]
- cdpCache = No Such Object available on this agent at this OID
- LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 lldpRemTable[0m]
- lldpRemTable = No Such Object available on this agent at this OID
- OSPF Discovery: SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='39'[0m]
- SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '39'[0m]
- SQL[[0;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL[0m]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0440 seconds with 4848 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
- ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
- ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='39' AND `context_name`=''[0m]
- SQL[[0;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'arp-table': 0.0590 seconds with 2360 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.02s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os.
- Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module bgp-peers ####
- SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 bgpLocalAs[0m]
- "M0"
- No BGP on hostPeers :
- SQL[[0;33mDELETE FROM `bgpPeers` WHERE device_id='39' AND context_name=''[0m]
- SQL[[0;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id='39' AND context_name=''[0m]
- SQL[[0;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id='39'[0m]
- >> Runtime for discovery module 'bgp-peers': 0.0150 seconds with 5456 bytes
- >> SNMP: [1/0.01s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '39'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.0460 seconds with 9296 bytes
- >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 diskIOEntry[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '39'[0m]
- >> Runtime for discovery module 'ucd-diskio': 0.0150 seconds with 3120 bytes
- >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS- Device+
- #### Load disco module applications ####
- Applications: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 nsExtendStatus[0m]
- nsExtendStatus = No Such Object available on this agent at this OID
- Available:
- Checking for:
- SQL[[0;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='39' ORDER BY `app_type`[0m]
- SQL[[0;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL[0m]
- >> Runtime for discovery module 'applications': 0.0240 seconds with 4752 bytes
- >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module applications ####
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS+ Device
- #### Load disco module stp ####
- SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '39'[0m]
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0170 seconds with 5712 bytes
- >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+ OS+ Device- Module [ ntp ] disabled on host.
- Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
- Modules status: Global- OS- Device Module [ mef ] disabled on os.
- Modules status: Global+ OS+ Device- Module [ wireless ] disabled on host.
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '39'[0m]
- SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '39'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qTpFdbPort[0m]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dTpFdbPort[0m]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.0410 seconds with 3032 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
- SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.119' WHERE `device_id` = '39'[0m]
- Discovered in 6.119 seconds
- SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','39','1526081733.504','6.279','1','librenms')[0m]
- ./discovery.php 39 2018-05-11 23:35:39 - 1 devices discovered in 6.279 secs
- SNMP [165/4.08s]: Get[133/3.35s] Getnext[1/0.01s] Walk[31/0.71s]
- MySQL [1057/0.85s]: Cell[675/0.44s] Row[11/0.00s] Rows[52/0.03s] Column[2/0.00s] Update[270/0.34s] Insert[41/0.01s] Delete[6/0.02s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]