From Gruff Zebra, 5 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. ===================================
  3. Version info:
  4. Commit SHA: 3e9f4b396e504627d8aae5f513c65f536fcf01ee
  5. Commit Date: 1526058363
  6. DB Schema: 249
  7. PHP: 7.2.5
  8. MySQL: 5.7.21-21
  9. RRDTool: 1.6.0
  10. SNMP: NET-SNMP 5.7.2
  11. ==================================DEBUG!
  12. Updating os_def.cache... Done
  13. SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `device_id` = '39' ORDER BY device_id DESC[0m]
  14. SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '39'[0m]
  15. acme01 39 acmepacket SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','0.18','0.20','0.18','39',NOW())[0m]
  16. SNMP Check response code: 0
  17. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
  18. Attempting to initialize OS: acmepacket
  19. Attempting to initialize OS: oracle
  20. OS initilized as Generic
  21.  
  22. Modules status: Global+ OS  Device  
  23. #### Load disco module core ####
  24. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
  25. .*.*.0 = acme01
  26. .*.*.0 = .*.4.1.9*
  27. .*.*.0 = Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
  28.  
  29.  
  30. >> Runtime for discovery module 'core': 0.0140 seconds with 1088 bytes
  31. >> SNMP: [2/0.32s] MySQL: [8/0.00s] RRD: [0/0.00s]
  32. #### Unload disco module core ####
  33.  
  34. Modules status: Global+ OS+ Device  
  35. #### Load disco module os ####
  36. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
  37. Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
  38.  
  39. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
  40. .*.4.1.9*
  41.  
  42. | Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) | .1.3.6.1.4.1.9148.1.1.2 |
  43. OS: Acme Packet (acmepacket)
  44.  
  45. >> Runtime for discovery module 'os': 0.6350 seconds with 1312 bytes
  46. >> SNMP: [2/0.64s] MySQL: [0/0.00s] RRD: [0/0.00s]
  47. #### Unload disco module os ####
  48.  
  49. Modules status: Global+ OS+ Device  
  50. #### Load disco module ports ####
  51. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifDescr[0m]
  52. ifDescr.1 = eth0 ETH
  53. ifDescr.2 = lo0
  54. ifDescr.5 = M0 GE
  55. ifDescr.6 = GE
  56. ifDescr.7 = M1 GE
  57. ifDescr.8 = GE
  58. ifDescr.13 = sp0 ETH
  59.  
  60. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifName[0m]
  61. ifName.5 = M0
  62. ifName.6 =
  63. ifName.7 = M1
  64. ifName.8 =
  65.  
  66. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifAlias[0m]
  67. ifAlias.5 =
  68. ifAlias.6 =
  69. ifAlias.7 =
  70. ifAlias.8 =
  71.  
  72. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifType[0m]
  73. ifType.1 = ethernetCsmacd
  74. ifType.2 = softwareLoopback
  75. ifType.5 = gigabitEthernet
  76. ifType.6 = gigabitEthernet
  77. ifType.7 = gigabitEthernet
  78. ifType.8 = gigabitEthernet
  79. ifType.13 = ethernetCsmacd
  80.  
  81. Array
  82. (
  83.     [1] => Array
  84.         (
  85.             [ifDescr] => eth0 ETH
  86.             [ifType] => ethernetCsmacd
  87.         )
  88.  
  89.     [2] => Array
  90.         (
  91.             [ifDescr] => lo0
  92.             [ifType] => softwareLoopback
  93.         )
  94.  
  95.     [5] => Array
  96.         (
  97.             [ifDescr] => M0 GE
  98.             [ifName] => M0
  99.             [ifAlias] =>
  100.             [ifType] => gigabitEthernet
  101.         )
  102.  
  103.     [6] => Array
  104.         (
  105.             [ifDescr] => GE
  106.             [ifName] =>
  107.             [ifAlias] =>
  108.             [ifType] => gigabitEthernet
  109.         )
  110.  
  111.     [7] => Array
  112.         (
  113.             [ifDescr] => M1 GE
  114.             [ifName] => M1
  115.             [ifAlias] =>
  116.             [ifType] => gigabitEthernet
  117.         )
  118.  
  119.     [8] => Array
  120.         (
  121.             [ifDescr] => GE
  122.             [ifName] =>
  123.             [ifAlias] =>
  124.             [ifType] => gigabitEthernet
  125.         )
  126.  
  127.     [13] => Array
  128.         (
  129.             [ifDescr] => sp0 ETH
  130.             [ifType] => ethernetCsmacd
  131.         )
  132.  
  133. )
  134. SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m]
  135. SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '39' ORDER BY port_id[0m]
  136. .......
  137.  
  138. >> Runtime for discovery module 'ports': 0.0660 seconds with 4216 bytes
  139. >> SNMP: [4/0.06s] MySQL: [2/0.00s] RRD: [0/0.00s]
  140. #### Unload disco module ports ####
  141.  
  142. Modules status: Global+ OS+ Device  
  143. #### Load disco module ports-stack ####
  144. SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '39'[0m]
  145. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifStackStatus[0m]
  146. ifStackStatus = No Such Object available on this agent at this OID
  147.  
  148.  
  149.  
  150. >> Runtime for discovery module 'ports-stack': 0.0180 seconds with 1768 bytes
  151. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  152. #### Unload disco module ports-stack ####
  153.  
  154. Modules status: Global+ OS+ Device  
  155. #### Load disco module entity-physical ####
  156.  
  157. Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalEntry[0m]
  158. entPhysicalDescr.1 = Assy, NetNet4500
  159. entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
  160. entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
  161. entPhysicalDescr.4 = Assy, 4-fan unit
  162. entPhysicalDescr.5 = PHY Slot
  163. entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
  164. entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
  165. entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
  166. entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
  167. entPhysicalDescr.10 = Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
  168. entPhysicalDescr.11 = Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
  169. entPhysicalDescr.12 = Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
  170. entPhysicalDescr.13 = Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
  171. entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
  172. entPhysicalDescr.19 = TLS Hardware Accelerator
  173. entPhysicalVendorType.1 = enterprises.9*.3.2.5
  174. entPhysicalVendorType.2 = enterprises.9*.5.3
  175. entPhysicalVendorType.3 = enterprises.9*.5.3
  176. entPhysicalVendorType.4 = enterprises.9*.6.3
  177. entPhysicalVendorType.5 = enterprises.9*.4.2.2
  178. entPhysicalVendorType.6 = enterprises.9*.8.2.12
  179. entPhysicalVendorType.7 = enterprises.9*.9.3
  180. entPhysicalVendorType.8 = enterprises.9*.9.3
  181. entPhysicalVendorType.9 = enterprises.9*.9.3
  182. entPhysicalVendorType.10 = enterprises.9*.9.2
  183. entPhysicalVendorType.11 = enterprises.9*.9.2
  184. entPhysicalVendorType.12 = enterprises.9*.9.2
  185. entPhysicalVendorType.13 = enterprises.9*.9.2
  186. entPhysicalVendorType.18 = enterprises.9*.8.4.7
  187. entPhysicalVendorType.19 = enterprises.9*.8.8.6
  188. entPhysicalContainedIn.1 = 0
  189. entPhysicalContainedIn.2 = 1
  190. entPhysicalContainedIn.3 = 1
  191. entPhysicalContainedIn.4 = 1
  192. entPhysicalContainedIn.5 = 1
  193. entPhysicalContainedIn.6 = 5
  194. entPhysicalContainedIn.7 = 6
  195. entPhysicalContainedIn.8 = 6
  196. entPhysicalContainedIn.9 = 6
  197. entPhysicalContainedIn.10 = 6
  198. entPhysicalContainedIn.11 = 6
  199. entPhysicalContainedIn.12 = 6
  200. entPhysicalContainedIn.13 = 6
  201. entPhysicalContainedIn.18 = 1
  202. entPhysicalContainedIn.19 = 1
  203. entPhysicalClass.1 = chassis
  204. entPhysicalClass.2 = powerSupply
  205. entPhysicalClass.3 = powerSupply
  206. entPhysicalClass.4 = fan
  207. entPhysicalClass.5 = container
  208. entPhysicalClass.6 = module
  209. entPhysicalClass.7 = port
  210. entPhysicalClass.8 = port
  211. entPhysicalClass.9 = port
  212. entPhysicalClass.10 = port
  213. entPhysicalClass.11 = port
  214. entPhysicalClass.12 = port
  215. entPhysicalClass.13 = port
  216. entPhysicalClass.18 = module
  217. entPhysicalClass.19 = module
  218. entPhysicalParentRelPos.1 = 0
  219. entPhysicalParentRelPos.2 = 1
  220. entPhysicalParentRelPos.3 = 2
  221. entPhysicalParentRelPos.4 = 3
  222. entPhysicalParentRelPos.5 = 4
  223. entPhysicalParentRelPos.6 = 1
  224. entPhysicalParentRelPos.7 = 1
  225. entPhysicalParentRelPos.8 = 2
  226. entPhysicalParentRelPos.9 = 3
  227. entPhysicalParentRelPos.10 = 1
  228. entPhysicalParentRelPos.11 = 2
  229. entPhysicalParentRelPos.12 = 3
  230. entPhysicalParentRelPos.13 = 4
  231. entPhysicalParentRelPos.18 = 5
  232. entPhysicalParentRelPos.19 = 7
  233. entPhysicalName.1 = Main Board
  234. entPhysicalName.2 = Power Supply A
  235. entPhysicalName.3 = Power Supply B
  236. entPhysicalName.4 = 4-Fan unit
  237. entPhysicalName.5 = PHY Slot
  238. entPhysicalName.6 = Quad port GiGE SFP PHY
  239. entPhysicalName.7 = Mgmt0
  240. entPhysicalName.8 = Mgmt1
  241. entPhysicalName.9 = Mgmt2
  242. entPhysicalName.10 = M0
  243. entPhysicalName.11 = M1
  244. entPhysicalName.12 =
  245. entPhysicalName.13 =
  246. entPhysicalName.18 = Host CPU Processor
  247. entPhysicalName.19 = BCM5823
  248. entPhysicalHardwareRev.1 = 5.10
  249. entPhysicalHardwareRev.2 =
  250. entPhysicalHardwareRev.3 =
  251. entPhysicalHardwareRev.4 =
  252. entPhysicalHardwareRev.5 =
  253. entPhysicalHardwareRev.6 = 4.11
  254. entPhysicalHardwareRev.7 =
  255. entPhysicalHardwareRev.8 =
  256. entPhysicalHardwareRev.9 =
  257. entPhysicalHardwareRev.10 =
  258. entPhysicalHardwareRev.11 =
  259. entPhysicalHardwareRev.12 =
  260. entPhysicalHardwareRev.13 =
  261. entPhysicalHardwareRev.18 =
  262. entPhysicalHardwareRev.19 = 1
  263. entPhysicalFirmwareRev.1 =
  264. entPhysicalFirmwareRev.2 =
  265. entPhysicalFirmwareRev.3 =
  266. entPhysicalFirmwareRev.4 =
  267. entPhysicalFirmwareRev.5 =
  268. entPhysicalFirmwareRev.6 =
  269. entPhysicalFirmwareRev.7 =
  270. entPhysicalFirmwareRev.8 =
  271. entPhysicalFirmwareRev.9 =
  272. entPhysicalFirmwareRev.10 =
  273. entPhysicalFirmwareRev.11 =
  274. entPhysicalFirmwareRev.12 =
  275. entPhysicalFirmwareRev.13 =
  276. entPhysicalFirmwareRev.18 =
  277. entPhysicalFirmwareRev.19 =
  278. entPhysicalSoftwareRev.1 =
  279. entPhysicalSoftwareRev.2 =
  280. entPhysicalSoftwareRev.3 =
  281. entPhysicalSoftwareRev.4 =
  282. entPhysicalSoftwareRev.5 =
  283. entPhysicalSoftwareRev.6 =
  284. entPhysicalSoftwareRev.7 =
  285. entPhysicalSoftwareRev.8 =
  286. entPhysicalSoftwareRev.9 =
  287. entPhysicalSoftwareRev.10 =
  288. entPhysicalSoftwareRev.11 =
  289. entPhysicalSoftwareRev.12 =
  290. entPhysicalSoftwareRev.13 =
  291. entPhysicalSoftwareRev.18 =
  292. entPhysicalSoftwareRev.19 =
  293. entPhysicalSerialNum.1 =
  294. entPhysicalSerialNum.2 =
  295. entPhysicalSerialNum.3 =
  296. entPhysicalSerialNum.4 =
  297. entPhysicalSerialNum.5 =
  298. entPhysicalSerialNum.6 =
  299. entPhysicalSerialNum.7 =
  300. entPhysicalSerialNum.8 =
  301. entPhysicalSerialNum.9 =
  302. entPhysicalSerialNum.10 =
  303. entPhysicalSerialNum.11 =
  304. entPhysicalSerialNum.12 =
  305. entPhysicalSerialNum.13 =
  306. entPhysicalSerialNum.18 =
  307. entPhysicalSerialNum.19 =
  308. entPhysicalMfgName.1 = Unknown manufacturer
  309. entPhysicalMfgName.2 =
  310. entPhysicalMfgName.3 =
  311. entPhysicalMfgName.4 =
  312. entPhysicalMfgName.5 =
  313. entPhysicalMfgName.6 = Benchmark Electronics
  314. entPhysicalMfgName.7 =
  315. entPhysicalMfgName.8 =
  316. entPhysicalMfgName.9 =
  317. entPhysicalMfgName.10 =
  318. entPhysicalMfgName.11 =
  319. entPhysicalMfgName.12 =
  320. entPhysicalMfgName.13 =
  321. entPhysicalMfgName.18 =
  322. entPhysicalMfgName.19 = BROADCOM
  323. entPhysicalModelName.1 = 002-0610-50
  324. entPhysicalModelName.2 =
  325. entPhysicalModelName.3 =
  326. entPhysicalModelName.4 =
  327. entPhysicalModelName.5 =
  328. entPhysicalModelName.6 = 002-0613-58
  329. entPhysicalModelName.7 =
  330. entPhysicalModelName.8 =
  331. entPhysicalModelName.9 =
  332. entPhysicalModelName.10 =
  333. entPhysicalModelName.11 =
  334. entPhysicalModelName.12 =
  335. entPhysicalModelName.13 =
  336. entPhysicalModelName.18 =
  337. entPhysicalModelName.19 = BCM5823
  338. entPhysicalAlias.1 =
  339. entPhysicalAlias.2 =
  340. entPhysicalAlias.3 =
  341. entPhysicalAlias.4 =
  342. entPhysicalAlias.5 =
  343. entPhysicalAlias.6 =
  344. entPhysicalAlias.7 =
  345. entPhysicalAlias.8 =
  346. entPhysicalAlias.9 =
  347. entPhysicalAlias.10 =
  348. entPhysicalAlias.11 =
  349. entPhysicalAlias.12 =
  350. entPhysicalAlias.13 =
  351. entPhysicalAlias.18 =
  352. entPhysicalAlias.19 =
  353. entPhysicalAssetID.1 =
  354. entPhysicalAssetID.2 =
  355. entPhysicalAssetID.3 =
  356. entPhysicalAssetID.4 =
  357. entPhysicalAssetID.5 =
  358. entPhysicalAssetID.6 =
  359. entPhysicalAssetID.7 =
  360. entPhysicalAssetID.8 =
  361. entPhysicalAssetID.9 =
  362. entPhysicalAssetID.10 =
  363. entPhysicalAssetID.11 =
  364. entPhysicalAssetID.12 =
  365. entPhysicalAssetID.13 =
  366. entPhysicalAssetID.18 =
  367. entPhysicalAssetID.19 =
  368. entPhysicalIsFRU.1 = false
  369. entPhysicalIsFRU.2 = true
  370. entPhysicalIsFRU.3 = true
  371. entPhysicalIsFRU.4 = true
  372. entPhysicalIsFRU.5 = false
  373. entPhysicalIsFRU.6 = true
  374. entPhysicalIsFRU.7 = false
  375. entPhysicalIsFRU.8 = false
  376. entPhysicalIsFRU.9 = false
  377. entPhysicalIsFRU.10 = true
  378. entPhysicalIsFRU.11 = true
  379. entPhysicalIsFRU.12 = true
  380. entPhysicalIsFRU.13 = true
  381. entPhysicalIsFRU.18 = false
  382. entPhysicalIsFRU.19 = true
  383.  
  384.  entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
  385. entAliasMappingIdentifier = No Such Object available on this agent at this OID
  386.  
  387. SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '1'[0m]
  388. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='Assy, NetNet4500',`entPhysicalClass` ='chassis',`entPhysicalName` ='Main Board',`entPhysicalModelName` ='002-0610-50',`entPhysicalSerialNum` ='151330035903',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Unknown manufacturer',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='enterprises.9148.6.1.1.3.2.5',`entPhysicalHardwareRev` ='5.10',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='1'[0m]
  389. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '2'[0m]
  390. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply A',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='2'[0m]
  391. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '3'[0m]
  392. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='3',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply B',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='3'[0m]
  393. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '4'[0m]
  394. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='4',`entPhysicalDescr` ='Assy, 4-fan unit',`entPhysicalClass` ='fan',`entPhysicalName` ='4-Fan unit',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.6.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='4'[0m]
  395. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '5'[0m]
  396. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='5',`entPhysicalDescr` ='PHY Slot',`entPhysicalClass` ='container',`entPhysicalName` ='PHY Slot',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.4.2.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='5'[0m]
  397. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '6'[0m]
  398. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='6',`entPhysicalDescr` ='Assy, 4 Port SFP with QOS and IPSec',`entPhysicalClass` ='module',`entPhysicalName` ='Quad port GiGE SFP PHY',`entPhysicalModelName` ='002-0613-58',`entPhysicalSerialNum` ='091128054782',`entPhysicalContainedIn` ='5',`entPhysicalMfgName` ='Benchmark Electronics',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.2.12',`entPhysicalHardwareRev` ='4.11',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='6'[0m]
  399. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '7'[0m]
  400. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='7',`entPhysicalDescr` ='Management Port 0 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='7'[0m]
  401. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '8'[0m]
  402. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='8',`entPhysicalDescr` ='Management Port 1 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='8'[0m]
  403. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '9'[0m]
  404. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='9',`entPhysicalDescr` ='Management Port 2 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt2',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='9'[0m]
  405. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '10'[0m]
  406. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='10',`entPhysicalDescr` ='Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='M0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='10'[0m]
  407. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '11'[0m]
  408. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='11',`entPhysicalDescr` ='Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='M1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='11'[0m]
  409. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '12'[0m]
  410. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='12',`entPhysicalDescr` ='Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='12'[0m]
  411. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '13'[0m]
  412. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='13',`entPhysicalDescr` ='Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='13'[0m]
  413. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '18'[0m]
  414. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='18',`entPhysicalDescr` ='Intel Pentium Core 2 Duo Module',`entPhysicalClass` ='module',`entPhysicalName` ='Host CPU Processor',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='5',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.4.7',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='18'[0m]
  415. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '19'[0m]
  416. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='19',`entPhysicalDescr` ='TLS Hardware Accelerator',`entPhysicalClass` ='module',`entPhysicalName` ='BCM5823',`entPhysicalModelName` ='BCM5823',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='BROADCOM',`entPhysicalParentRelPos` ='7',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.8.6',`entPhysicalHardwareRev` ='1',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='19'[0m]
  417. .
  418. SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '39'[0m]
  419.  
  420. >> Runtime for discovery module 'entity-physical': 0.1700 seconds with 9744 bytes
  421. >> SNMP: [1/0.14s] MySQL: [31/0.01s] RRD: [0/0.00s]
  422. #### Unload disco module entity-physical ####
  423.  
  424. Modules status: Global- OS- Device- Module [ entity-state ] disabled on host.
  425.  
  426. Modules status: Global+ OS+ Device  
  427. #### Load disco module processors ####
  428. Caching data: sensors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonCpuCoreTable[0m]
  429. apEnvMonCpuCoreTable = No Such Object available on this agent at this OID
  430.  
  431. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPhyCardStatusTable[0m]
  432. apEnvMonPhyCardStatusType.1 = 0
  433. apEnvMonPhyCardStatusDescr.1 = "Phy"
  434. apEnvMonPhyCardState.1 = 2
  435.  
  436. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPowerSupplyStatusTable[0m]
  437. apEnvMonPowerSupplyStatusType.1 = 1
  438. apEnvMonPowerSupplyStatusType.2 = 0
  439. apEnvMonPowerSupplyStatusDescr.1 = "Power Supply A"
  440. apEnvMonPowerSupplyStatusDescr.2 = "Power Supply B"
  441. apEnvMonPowerSupplyState.1 = 2
  442. apEnvMonPowerSupplyState.2 = 2
  443.  
  444. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonFanStatusTable[0m]
  445. apEnvMonFanStatusType.1 = 11
  446. apEnvMonFanStatusType.2 = 12
  447. apEnvMonFanStatusType.3 = 13
  448. apEnvMonFanStatusType.4 = 14
  449. apEnvMonFanStatusDescr.1 = "Fan 1 Speed"
  450. apEnvMonFanStatusDescr.2 = "Fan 2 Speed"
  451. apEnvMonFanStatusDescr.3 = "Fan 3 Speed"
  452. apEnvMonFanStatusDescr.4 = "Fan 4 Speed"
  453. apEnvMonFanStatusValue.1 = 100
  454. apEnvMonFanStatusValue.2 = 100
  455. apEnvMonFanStatusValue.3 = 100
  456. apEnvMonFanStatusValue.4 = 100
  457. apEnvMonFanState.1 = 2
  458. apEnvMonFanState.2 = 2
  459. apEnvMonFanState.3 = 2
  460. apEnvMonFanState.4 = 2
  461.  
  462. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonTemperatureStatusTable[0m]
  463. apEnvMonTemperatureStatusType.1 = 6
  464. apEnvMonTemperatureStatusType.2 = 5
  465. apEnvMonTemperatureStatusType.3 = 4
  466. apEnvMonTemperatureStatusType.4 = 7
  467. apEnvMonTemperatureStatusDescr.1 = "CPU Temperature (degrees Celsius)"
  468. apEnvMonTemperatureStatusDescr.2 = "Main Board Temperature 0 (degrees Celcius)"
  469. apEnvMonTemperatureStatusDescr.3 = "Main Board Temperature 1 (degrees Celcius)"
  470. apEnvMonTemperatureStatusDescr.4 = "PHY Temperature 0 (degrees Celcius)"
  471. apEnvMonTemperatureStatusValue.1 = 45
  472. apEnvMonTemperatureStatusValue.2 = 31
  473. apEnvMonTemperatureStatusValue.3 = 28
  474. apEnvMonTemperatureStatusValue.4 = 43
  475. apEnvMonTemperatureState.1 = 2
  476. apEnvMonTemperatureState.2 = 2
  477. apEnvMonTemperatureState.3 = 2
  478. apEnvMonTemperatureState.4 = 2
  479.  
  480. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonVoltageStatusTable[0m]
  481. apEnvMonVoltageStatusType.1 = 8
  482. apEnvMonVoltageStatusType.2 = 12
  483. apEnvMonVoltageStatusType.3 = 13
  484. apEnvMonVoltageStatusType.4 = 1
  485. apEnvMonVoltageStatusType.5 = 2
  486. apEnvMonVoltageStatusType.6 = 3
  487. apEnvMonVoltageStatusType.7 = 15
  488. apEnvMonVoltageStatusDescr.1 = "1.2V voltage (millivolts)"
  489. apEnvMonVoltageStatusDescr.2 = "1.5V voltage (millivolts)"
  490. apEnvMonVoltageStatusDescr.3 = "1.8V voltage (millivolts)"
  491. apEnvMonVoltageStatusDescr.4 = "2.5V voltage (millivolts)"
  492. apEnvMonVoltageStatusDescr.5 = "3.3V voltage (millivolts)"
  493. apEnvMonVoltageStatusDescr.6 = "5.0V voltage (millivolts)"
  494. apEnvMonVoltageStatusDescr.7 = "3.3V Aux voltage (millivolts)"
  495. apEnvMonVoltageStatusValue.1 = 1205
  496. apEnvMonVoltageStatusValue.2 = 1493
  497. apEnvMonVoltageStatusValue.3 = 1794
  498. apEnvMonVoltageStatusValue.4 = 2483
  499. apEnvMonVoltageStatusValue.5 = 3288
  500. apEnvMonVoltageStatusValue.6 = 5058
  501. apEnvMonVoltageStatusValue.7 = 3263
  502. apEnvMonVoltageState.1 = 2
  503. apEnvMonVoltageState.2 = 2
  504. apEnvMonVoltageState.3 = 2
  505. apEnvMonVoltageState.4 = 2
  506. apEnvMonVoltageState.5 = 2
  507. apEnvMonVoltageState.6 = 2
  508. apEnvMonVoltageState.7 = 2
  509.  
  510. processors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apSysCPUUtil[0m]
  511. apSysCPUUtil.0 = 35
  512.  
  513.  
  514. YAML Discovery Data: Array
  515. (
  516.     [data] => Array
  517.         (
  518.             [0] => Array
  519.                 (
  520.                     [oid] => apSysCPUUtil
  521.                     [num_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1
  522.                     [type] => acmepacket
  523.                 )
  524.  
  525.         )
  526.  
  527. )
  528. Data apSysCPUUtil: Array
  529. (
  530.     [0] => Array
  531.         (
  532.             [apSysCPUUtil] => 35
  533.         )
  534.  
  535. )
  536. Discovered LibreNMS\Device\Processor Array
  537. (
  538.     [processor_id] =>
  539.     [entPhysicalIndex] => 0
  540.     [hrDeviceIndex] => 0
  541.     [device_id] => 39
  542.     [processor_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1
  543.     [processor_index] => 0
  544.     [processor_type] => acmepacket
  545.     [processor_usage] => 35
  546.     [processor_descr] => Processor
  547.     [processor_precision] => 1
  548.     [processor_perc_warn] => 75
  549. )
  550. SQL[[0;33mSELECT * FROM `processors` WHERE  device_id='39' AND processor_index='0' AND processor_type='acmepacket'[0m]
  551. .SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`='39' AND `processor_id` NOT IN ('761')[0m]
  552. SQL[[0;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL[0m]
  553.  
  554.  
  555. >> Runtime for discovery module 'processors': 0.1460 seconds with 180008 bytes
  556. >> SNMP: [7/0.14s] MySQL: [3/0.00s] RRD: [0/0.00s]
  557. #### Unload disco module processors ####
  558.  
  559. Modules status: Global+ OS+ Device  
  560. #### Load disco module mempools ####
  561. SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '39' AND `mempool_type` = 'cemp'[0m]
  562. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
  563. hpLocalMem = No Such Object available on this agent at this OID
  564.  
  565. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
  566. hpGlobalMem = No Such Object available on this agent at this OID
  567.  
  568. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m]
  569. hrStorageEntry = No Such Object available on this agent at this OID
  570.  
  571. SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id`  = '39'[0m]
  572.  
  573.  
  574. >> Runtime for discovery module 'mempools': 0.0700 seconds with 41872 bytes
  575. >> SNMP: [3/0.07s] MySQL: [2/0.00s] RRD: [0/0.00s]
  576. #### Unload disco module mempools ####
  577.  
  578. Modules status: Global+ OS+ Device  
  579. #### Load disco module cisco-vrf-lite ####
  580. SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '39' [0m]
  581.  
  582. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2640 bytes
  583. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  584. #### Unload disco module cisco-vrf-lite ####
  585.  
  586. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  587.  
  588. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  589.  
  590. Modules status: Global- OS- Device  Module [ vrf ] disabled on os.
  591.  
  592. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  593.  
  594. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  595.  
  596. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  597.  
  598. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  599.  
  600. Modules status: Global+ OS+ Device  
  601. #### Load disco module ipv4-addresses ####
  602. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntIfIndex[0m]
  603. ipAdEntIfIndex.* 5
  604.  
  605. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
  606. *
  607.  
  608. SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '39' AND `ifIndex` = '5'[0m]
  609. SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '39' AND `ifIndex` = '5'[0m]
  610. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  611. SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  612. sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  613. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542' [0m]
  614. SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542'[0m]
  615. .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
  616. *
  617.  
  618. >> Runtime for discovery module 'ipv4-addresses': 3.1630 seconds with 36792 bytes
  619. >> SNMP: [128/2.38s] MySQL: [890/0.78s] RRD: [0/0.00s]
  620. #### Unload disco module ipv4-addresses ####
  621.  
  622. Modules status: Global+ OS+ Device  
  623. #### Load disco module ipv6-addresses ####
  624. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
  625. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  626.  
  627. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
  628. .*.*.8.1.2 No Such Object available on this agent at this OID
  629.  
  630. SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '39' OR `ports`.`device_id` IS NULL[0m]
  631.  
  632.  
  633. >> Runtime for discovery module 'ipv6-addresses': 0.0330 seconds with 1376 bytes
  634. >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
  635. #### Unload disco module ipv6-addresses ####
  636.  
  637. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  638.  
  639. Modules status: Global+ OS+ Device  
  640. #### Load disco module sensors ####
  641.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalDescr[0m]
  642. entPhysicalDescr.1 = Assy, NetNet4500
  643. entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
  644. entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
  645. entPhysicalDescr.4 = Assy, 4-fan unit
  646. entPhysicalDescr.5 = PHY Slot
  647. entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
  648. entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
  649. entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
  650. entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
  651. entPhysicalDescr.10 = Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
  652. entPhysicalDescr.11 = Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
  653. entPhysicalDescr.12 = Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
  654. entPhysicalDescr.13 = Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
  655. entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
  656. entPhysicalDescr.19 = TLS Hardware Accelerator
  657.  
  658.  entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalName[0m]
  659. entPhysicalName.1 = Main Board
  660. entPhysicalName.2 = Power Supply A
  661. entPhysicalName.3 = Power Supply B
  662. entPhysicalName.4 = 4-Fan unit
  663. entPhysicalName.5 = PHY Slot
  664. entPhysicalName.6 = Quad port GiGE SFP PHY
  665. entPhysicalName.7 = Mgmt0
  666. entPhysicalName.8 = Mgmt1
  667. entPhysicalName.9 = Mgmt2
  668. entPhysicalName.10 = M0
  669. entPhysicalName.11 = M1
  670. entPhysicalName.12 =
  671. entPhysicalName.13 =
  672. entPhysicalName.18 = Host CPU Processor
  673. entPhysicalName.19 = BCM5823
  674.  
  675.  entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorType[0m]
  676. entPhySensorType = No Such Object available on this agent at this OID
  677.  
  678.  entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorScale[0m]
  679. entPhySensorScale = No Such Object available on this agent at this OID
  680.  
  681.  entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorPrecision[0m]
  682. entPhySensorPrecision = No Such Object available on this agent at this OID
  683.  
  684.  entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorValue[0m]
  685. entPhySensorValue = No Such Object available on this agent at this OID
  686.  
  687.  
  688. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'ipmi_hostname' [0m]
  689. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  690. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  691. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  692. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  693. Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  694.  
  695. Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  696.  
  697. Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  698.  
  699. Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  700.  
  701. Fanspeed: Dynamic Discovery (fanspeed): Array
  702. (
  703.     [data] => Array
  704.         (
  705.             [0] => Array
  706.                 (
  707.                     [oid] => apEnvMonFanStatusTable
  708.                     [value] => apEnvMonFanStatusValue
  709.                     [num_oid] => .
  710.                     [descr] => apEnvMonFanStatusDescr
  711.                     [index] => apEnvMonFanStatusValue.{{ $index }}
  712.                 )
  713.  
  714.         )
  715.  
  716. )
  717. Data apEnvMonFanStatusTable: Array
  718. (
  719.     [1] => Array
  720.         (
  721.             [apEnvMonFanStatusType] => 11
  722.             [apEnvMonFanStatusDescr] => Fan 1 Speed
  723.             [apEnvMonFanStatusValue] => 100
  724.             [apEnvMonFanState] => 2
  725.         )
  726.  
  727.     [2] => Array
  728.         (
  729.             [apEnvMonFanStatusType] => 12
  730.             [apEnvMonFanStatusDescr] => Fan 2 Speed
  731.             [apEnvMonFanStatusValue] => 100
  732.             [apEnvMonFanState] => 2
  733.         )
  734.  
  735.     [3] => Array
  736.         (
  737.             [apEnvMonFanStatusType] => 13
  738.             [apEnvMonFanStatusDescr] => Fan 3 Speed
  739.             [apEnvMonFanStatusValue] => 100
  740.             [apEnvMonFanState] => 2
  741.         )
  742.  
  743.     [4] => Array
  744.         (
  745.             [apEnvMonFanStatusType] => 14
  746.             [apEnvMonFanStatusDescr] => Fan 4 Speed
  747.             [apEnvMonFanStatusValue] => 100
  748.             [apEnvMonFanState] => 2
  749.         )
  750.  
  751. )
  752. Final sensor value: 100
  753. Cur 100, Low: null, Low Warn: null, Warn: null, High: null
  754. Discover sensor: .1, apEnvMonFanStatusValue.1, acmepacket, Fan 1 Speed, snmp, 1, 1, , 100
  755. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.1'[0m]
  756. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','fanspeed','39','.1','apEnvMonFanStatusValue.1','acmepacket','Fan 1 Speed','1','1','180','80','100')[0m]
  757. ( 1045 inserted )
  758. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1045','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.1 Fan 1 Speed','')[0m]
  759. Final sensor value: 100
  760. Cur 100, Low: null, Low Warn: null, Warn: null, High: null
  761. Discover sensor: .2, apEnvMonFanStatusValue.2, acmepacket, Fan 2 Speed, snmp, 1, 1, , 100
  762. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.2'[0m]
  763. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','fanspeed','39','.2','apEnvMonFanStatusValue.2','acmepacket','Fan 2 Speed','1','1','180','80','100')[0m]
  764. ( 1046 inserted )
  765. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1046','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.2 Fan 2 Speed','')[0m]
  766. Final sensor value: 100
  767. Cur 100, Low: null, Low Warn: null, Warn: null, High: null
  768. Discover sensor: .3, apEnvMonFanStatusValue.3, acmepacket, Fan 3 Speed, snmp, 1, 1, , 100
  769. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.3'[0m]
  770. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','fanspeed','39','.3','apEnvMonFanStatusValue.3','acmepacket','Fan 3 Speed','1','1','180','80','100')[0m]
  771. ( 1047 inserted )
  772. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1047','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.3 Fan 3 Speed','')[0m]
  773. Final sensor value: 100
  774. Cur 100, Low: null, Low Warn: null, Warn: null, High: null
  775. Discover sensor: .4, apEnvMonFanStatusValue.4, acmepacket, Fan 4 Speed, snmp, 1, 1, , 100
  776. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.4'[0m]
  777. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','fanspeed','39','.4','apEnvMonFanStatusValue.4','acmepacket','Fan 4 Speed','1','1','180','80','100')[0m]
  778. ( 1048 inserted )
  779. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1048','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.4 Fan 4 Speed','')[0m]
  780. Array
  781. (
  782.     [acmepacket] => Array
  783.         (
  784.             [apEnvMonFanStatusValue.1] => 1
  785.             [apEnvMonFanStatusValue.2] => 1
  786.             [apEnvMonFanStatusValue.3] => 1
  787.             [apEnvMonFanStatusValue.4] => 1
  788.         )
  789.  
  790. )
  791. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  792. apEnvMonFanStatusValue.1 -> acmepacket
  793. apEnvMonFanStatusValue.2 -> acmepacket
  794. apEnvMonFanStatusValue.3 -> acmepacket
  795. apEnvMonFanStatusValue.4 -> acmepacket
  796.  
  797. Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  798.  
  799. Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  800.  
  801. Load: Dynamic Discovery (load): Array
  802. (
  803.     [data] => Array
  804.         (
  805.             [0] => Array
  806.                 (
  807.                     [oid] => apEnvMonCpuCoreTable
  808.                     [value] => apEnvMonCpuCoreUsage
  809.                     [num_oid] => .
  810.                     [descr] => apEnvMonCpuCoreDescr
  811.                 )
  812.  
  813.         )
  814.  
  815. )
  816. Data apEnvMonCpuCoreTable: Array
  817. (
  818. )
  819. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  820.  
  821. Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  822.  
  823. Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  824.  
  825. Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  826.  
  827. State: Dynamic Discovery (state): Array
  828. (
  829.     [data] => Array
  830.         (
  831.             [0] => Array
  832.                 (
  833.                     [oid] => apEnvMonPhyCardStatusTable
  834.                     [value] => apEnvMonPhyCardState
  835.                     [num_oid] => .
  836.                     [descr] => apEnvMonPhyCardStatusDescr
  837.                 )
  838.  
  839.             [1] => Array
  840.                 (
  841.                     [oid] => apEnvMonPowerSupplyStatusTable
  842.                     [value] => apEnvMonPowerSupplyState
  843.                     [num_oid] => .
  844.                     [descr] => apEnvMonPowerSupplyStatusDescr
  845.                     [index] => apEnvMonPowerSupplyStatusIndex.{{ $index }}
  846.                 )
  847.  
  848.         )
  849.  
  850. )
  851. Data apEnvMonPhyCardStatusTable: Array
  852. (
  853.     [1] => Array
  854.         (
  855.             [apEnvMonPhyCardStatusType] => 0
  856.             [apEnvMonPhyCardStatusDescr] => Phy
  857.             [apEnvMonPhyCardState] => 2
  858.         )
  859.  
  860. )
  861. Final sensor value: 2
  862. Cur 2, Low: null, Low Warn: null, Warn: null, High: null
  863. SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPhyCardStatusTable' LIMIT 1[0m]
  864. SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '21'[0m]
  865. Discover sensor: .1, 1, apEnvMonPhyCardStatusTable, Phy, snmp, 1, 1, , 2
  866. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m]
  867. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`)  VALUES ('snmp','state','39','.1','1','apEnvMonPhyCardStatusTable','Phy','1','1','2')[0m]
  868. ( 1049 inserted )
  869. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1049','sensor',NOW(),'3','Sensor Added: state apEnvMonPhyCardStatusTable 1 Phy','')[0m]
  870. SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m]
  871. SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPhyCardStatusTable'[0m]
  872. SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('1049','21')[0m]
  873. Data apEnvMonPowerSupplyStatusTable: Array
  874. (
  875.     [1] => Array
  876.         (
  877.             [apEnvMonPowerSupplyStatusType] => 1
  878.             [apEnvMonPowerSupplyStatusDescr] => Power Supply A
  879.             [apEnvMonPowerSupplyState] => 2
  880.         )
  881.  
  882.     [2] => Array
  883.         (
  884.             [apEnvMonPowerSupplyStatusType] => 0
  885.             [apEnvMonPowerSupplyStatusDescr] => Power Supply B
  886.             [apEnvMonPowerSupplyState] => 2
  887.         )
  888.  
  889. )
  890. Final sensor value: 2
  891. Cur 2, Low: null, Low Warn: null, Warn: null, High: null
  892. SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m]
  893. SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m]
  894. Discover sensor: .1, apEnvMonPowerSupplyStatusIndex.1, apEnvMonPowerSupplyStatusTable, Power Supply A, snmp, 1, 1, , 2
  895. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m]
  896. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`)  VALUES ('snmp','state','39','.1','apEnvMonPowerSupplyStatusIndex.1','apEnvMonPowerSupplyStatusTable','Power Supply A','1','1','2')[0m]
  897. ( 1050 inserted )
  898. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1050','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.1 Power Supply A','')[0m]
  899. SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m]
  900. SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m]
  901. SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('1050','22')[0m]
  902. Final sensor value: 2
  903. Cur 2, Low: null, Low Warn: null, Warn: null, High: null
  904. SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m]
  905. SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m]
  906. Discover sensor: .2, apEnvMonPowerSupplyStatusIndex.2, apEnvMonPowerSupplyStatusTable, Power Supply B, snmp, 1, 1, , 2
  907. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m]
  908. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`)  VALUES ('snmp','state','39','.2','apEnvMonPowerSupplyStatusIndex.2','apEnvMonPowerSupplyStatusTable','Power Supply B','1','1','2')[0m]
  909. ( 1051 inserted )
  910. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1051','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.2 Power Supply B','')[0m]
  911. SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m]
  912. SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m]
  913. SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('1051','22')[0m]
  914. Array
  915. (
  916.     [apEnvMonPhyCardStatusTable] => Array
  917.         (
  918.             [1] => 1
  919.         )
  920.  
  921.     [apEnvMonPowerSupplyStatusTable] => Array
  922.         (
  923.             [apEnvMonPowerSupplyStatusIndex.1] => 1
  924.             [apEnvMonPowerSupplyStatusIndex.2] => 1
  925.         )
  926.  
  927. )
  928. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  929. 1 -> apEnvMonPhyCardStatusTable
  930. apEnvMonPowerSupplyStatusIndex.1 -> apEnvMonPowerSupplyStatusTable
  931. apEnvMonPowerSupplyStatusIndex.2 -> apEnvMonPowerSupplyStatusTable
  932.  
  933. Temperature: Dynamic Discovery (temperature): Array
  934. (
  935.     [data] => Array
  936.         (
  937.             [0] => Array
  938.                 (
  939.                     [oid] => apEnvMonTemperatureStatusTable
  940.                     [value] => apEnvMonTemperatureStatusValue
  941.                     [num_oid] => .
  942.                     [descr] => apEnvMonTemperatureStatusDescr
  943.                     [index] => apEnvMonTemperatureStatusIndex.{{ $index }}
  944.                 )
  945.  
  946.         )
  947.  
  948. )
  949. Data apEnvMonTemperatureStatusTable: Array
  950. (
  951.     [1] => Array
  952.         (
  953.             [apEnvMonTemperatureStatusType] => 6
  954.             [apEnvMonTemperatureStatusDescr] => CPU Temperature (degrees Celsius)
  955.             [apEnvMonTemperatureStatusValue] => 45
  956.             [apEnvMonTemperatureState] => 2
  957.         )
  958.  
  959.     [2] => Array
  960.         (
  961.             [apEnvMonTemperatureStatusType] => 5
  962.             [apEnvMonTemperatureStatusDescr] => Main Board Temperature 0 (degrees Celcius)
  963.             [apEnvMonTemperatureStatusValue] => 31
  964.             [apEnvMonTemperatureState] => 2
  965.         )
  966.  
  967.     [3] => Array
  968.         (
  969.             [apEnvMonTemperatureStatusType] => 4
  970.             [apEnvMonTemperatureStatusDescr] => Main Board Temperature 1 (degrees Celcius)
  971.             [apEnvMonTemperatureStatusValue] => 28
  972.             [apEnvMonTemperatureState] => 2
  973.         )
  974.  
  975.     [4] => Array
  976.         (
  977.             [apEnvMonTemperatureStatusType] => 7
  978.             [apEnvMonTemperatureStatusDescr] => PHY Temperature 0 (degrees Celcius)
  979.             [apEnvMonTemperatureStatusValue] => 43
  980.             [apEnvMonTemperatureState] => 2
  981.         )
  982.  
  983. )
  984. Final sensor value: 45
  985. Cur 45, Low: null, Low Warn: null, Warn: null, High: null
  986. Discover sensor: .1, apEnvMonTemperatureStatusIndex.1, acmepacket, CPU Temperature (degrees Celsius), snmp, 1, 1, , 45
  987. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.1'[0m]
  988. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','temperature','39','.1','apEnvMonTemperatureStatusIndex.1','acmepacket','CPU Temperature (degrees Celsius)','1','1','65','35','45')[0m]
  989. ( 1052 inserted )
  990. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1052','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.1 CPU Temperature (degrees Celsius)','')[0m]
  991. Final sensor value: 31
  992. Cur 31, Low: null, Low Warn: null, Warn: null, High: null
  993. Discover sensor: .2, apEnvMonTemperatureStatusIndex.2, acmepacket, Main Board Temperature 0 (degrees Celcius), snmp, 1, 1, , 31
  994. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.2'[0m]
  995. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','temperature','39','.2','apEnvMonTemperatureStatusIndex.2','acmepacket','Main Board Temperature 0 (degrees Celcius)','1','1','51','21','31')[0m]
  996. ( 1053 inserted )
  997. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1053','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.2 Main Board Temperature 0 (degrees Celcius)','')[0m]
  998. Final sensor value: 28
  999. Cur 28, Low: null, Low Warn: null, Warn: null, High: null
  1000. Discover sensor: .3, apEnvMonTemperatureStatusIndex.3, acmepacket, Main Board Temperature 1 (degrees Celcius), snmp, 1, 1, , 28
  1001. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.3'[0m]
  1002. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','temperature','39','.3','apEnvMonTemperatureStatusIndex.3','acmepacket','Main Board Temperature 1 (degrees Celcius)','1','1','48','18','28')[0m]
  1003. ( 1054 inserted )
  1004. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1054','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.3 Main Board Temperature 1 (degrees Celcius)','')[0m]
  1005. Final sensor value: 43
  1006. Cur 43, Low: null, Low Warn: null, Warn: null, High: null
  1007. Discover sensor: .4, apEnvMonTemperatureStatusIndex.4, acmepacket, PHY Temperature 0 (degrees Celcius), snmp, 1, 1, , 43
  1008. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.4'[0m]
  1009. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','temperature','39','.4','apEnvMonTemperatureStatusIndex.4','acmepacket','PHY Temperature 0 (degrees Celcius)','1','1','63','33','43')[0m]
  1010. ( 1055 inserted )
  1011. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1055','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.4 PHY Temperature 0 (degrees Celcius)','')[0m]
  1012. Array
  1013. (
  1014.     [acmepacket] => Array
  1015.         (
  1016.             [apEnvMonTemperatureStatusIndex.1] => 1
  1017.             [apEnvMonTemperatureStatusIndex.2] => 1
  1018.             [apEnvMonTemperatureStatusIndex.3] => 1
  1019.             [apEnvMonTemperatureStatusIndex.4] => 1
  1020.         )
  1021.  
  1022. )
  1023. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1024. apEnvMonTemperatureStatusIndex.1 -> acmepacket
  1025. apEnvMonTemperatureStatusIndex.2 -> acmepacket
  1026. apEnvMonTemperatureStatusIndex.3 -> acmepacket
  1027. apEnvMonTemperatureStatusIndex.4 -> acmepacket
  1028.  
  1029. Voltage: Dynamic Discovery (voltage): Array
  1030. (
  1031.     [data] => Array
  1032.         (
  1033.             [0] => Array
  1034.                 (
  1035.                     [oid] => apEnvMonVoltageStatusTable
  1036.                     [value] => apEnvMonVoltageStatusValue
  1037.                     [num_oid] => .
  1038.                     [descr] => apEnvMonVoltageStatusDescr
  1039.                     [divisor] => 1000
  1040.                     [index] => apEnvMonVoltageStatusIndex.{{ $index }}
  1041.                 )
  1042.  
  1043.         )
  1044.  
  1045. )
  1046. Data apEnvMonVoltageStatusTable: Array
  1047. (
  1048.     [1] => Array
  1049.         (
  1050.             [apEnvMonVoltageStatusType] => 8
  1051.             [apEnvMonVoltageStatusDescr] => 1.2V voltage (millivolts)
  1052.             [apEnvMonVoltageStatusValue] => 1205
  1053.             [apEnvMonVoltageState] => 2
  1054.         )
  1055.  
  1056.     [2] => Array
  1057.         (
  1058.             [apEnvMonVoltageStatusType] => 12
  1059.             [apEnvMonVoltageStatusDescr] => 1.5V voltage (millivolts)
  1060.             [apEnvMonVoltageStatusValue] => 1493
  1061.             [apEnvMonVoltageState] => 2
  1062.         )
  1063.  
  1064.     [3] => Array
  1065.         (
  1066.             [apEnvMonVoltageStatusType] => 13
  1067.             [apEnvMonVoltageStatusDescr] => 1.8V voltage (millivolts)
  1068.             [apEnvMonVoltageStatusValue] => 1794
  1069.             [apEnvMonVoltageState] => 2
  1070.         )
  1071.  
  1072.     [4] => Array
  1073.         (
  1074.             [apEnvMonVoltageStatusType] => 1
  1075.             [apEnvMonVoltageStatusDescr] => 2.5V voltage (millivolts)
  1076.             [apEnvMonVoltageStatusValue] => 2483
  1077.             [apEnvMonVoltageState] => 2
  1078.         )
  1079.  
  1080.     [5] => Array
  1081.         (
  1082.             [apEnvMonVoltageStatusType] => 2
  1083.             [apEnvMonVoltageStatusDescr] => 3.3V voltage (millivolts)
  1084.             [apEnvMonVoltageStatusValue] => 3288
  1085.             [apEnvMonVoltageState] => 2
  1086.         )
  1087.  
  1088.     [6] => Array
  1089.         (
  1090.             [apEnvMonVoltageStatusType] => 3
  1091.             [apEnvMonVoltageStatusDescr] => 5.0V voltage (millivolts)
  1092.             [apEnvMonVoltageStatusValue] => 5058
  1093.             [apEnvMonVoltageState] => 2
  1094.         )
  1095.  
  1096.     [7] => Array
  1097.         (
  1098.             [apEnvMonVoltageStatusType] => 15
  1099.             [apEnvMonVoltageStatusDescr] => 3.3V Aux voltage (millivolts)
  1100.             [apEnvMonVoltageStatusValue] => 3263
  1101.             [apEnvMonVoltageState] => 2
  1102.         )
  1103.  
  1104. )
  1105. Final sensor value: 1205
  1106. Cur 1205, Low: null, Low Warn: null, Warn: null, High: null
  1107. Discover sensor: .1, apEnvMonVoltageStatusIndex.1, acmepacket, 1.2V voltage (millivolts), snmp, 1000, 1, , 1.205
  1108. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.1'[0m]
  1109. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.1','apEnvMonVoltageStatusIndex.1','acmepacket','1.2V voltage (millivolts)','1000','1','1.38575','1.02425','1.205')[0m]
  1110. ( 1056 inserted )
  1111. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1056','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.1 1.2V voltage (millivolts)','')[0m]
  1112. Final sensor value: 1493
  1113. Cur 1493, Low: null, Low Warn: null, Warn: null, High: null
  1114. Discover sensor: .2, apEnvMonVoltageStatusIndex.2, acmepacket, 1.5V voltage (millivolts), snmp, 1000, 1, , 1.493
  1115. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.2'[0m]
  1116. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.2','apEnvMonVoltageStatusIndex.2','acmepacket','1.5V voltage (millivolts)','1000','1','1.71695','1.26905','1.493')[0m]
  1117. ( 1057 inserted )
  1118. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1057','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.2 1.5V voltage (millivolts)','')[0m]
  1119. Final sensor value: 1794
  1120. Cur 1794, Low: null, Low Warn: null, Warn: null, High: null
  1121. Discover sensor: .3, apEnvMonVoltageStatusIndex.3, acmepacket, 1.8V voltage (millivolts), snmp, 1000, 1, , 1.794
  1122. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.3'[0m]
  1123. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.3','apEnvMonVoltageStatusIndex.3','acmepacket','1.8V voltage (millivolts)','1000','1','2.0631','1.5249','1.794')[0m]
  1124. ( 1058 inserted )
  1125. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1058','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.3 1.8V voltage (millivolts)','')[0m]
  1126. Final sensor value: 2483
  1127. Cur 2483, Low: null, Low Warn: null, Warn: null, High: null
  1128. Discover sensor: .4, apEnvMonVoltageStatusIndex.4, acmepacket, 2.5V voltage (millivolts), snmp, 1000, 1, , 2.483
  1129. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.4'[0m]
  1130. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.4','apEnvMonVoltageStatusIndex.4','acmepacket','2.5V voltage (millivolts)','1000','1','2.85545','2.11055','2.483')[0m]
  1131. ( 1059 inserted )
  1132. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1059','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.4 2.5V voltage (millivolts)','')[0m]
  1133. Final sensor value: 3288
  1134. Cur 3288, Low: null, Low Warn: null, Warn: null, High: null
  1135. Discover sensor: .5, apEnvMonVoltageStatusIndex.5, acmepacket, 3.3V voltage (millivolts), snmp, 1000, 1, , 3.288
  1136. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.5'[0m]
  1137. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.5','apEnvMonVoltageStatusIndex.5','acmepacket','3.3V voltage (millivolts)','1000','1','3.7812','2.7948','3.288')[0m]
  1138. ( 1060 inserted )
  1139. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1060','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.5 3.3V voltage (millivolts)','')[0m]
  1140. Final sensor value: 5058
  1141. Cur 5058, Low: null, Low Warn: null, Warn: null, High: null
  1142. Discover sensor: .6, apEnvMonVoltageStatusIndex.6, acmepacket, 5.0V voltage (millivolts), snmp, 1000, 1, , 5.058
  1143. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.6'[0m]
  1144. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.6','apEnvMonVoltageStatusIndex.6','acmepacket','5.0V voltage (millivolts)','1000','1','5.8167','4.2993','5.058')[0m]
  1145. ( 1061 inserted )
  1146. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1061','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.6 5.0V voltage (millivolts)','')[0m]
  1147. Final sensor value: 3263
  1148. Cur 3263, Low: null, Low Warn: null, Warn: null, High: null
  1149. Discover sensor: .7, apEnvMonVoltageStatusIndex.7, acmepacket, 3.3V Aux voltage (millivolts), snmp, 1000, 1, , 3.263
  1150. SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.7'[0m]
  1151. SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`)  VALUES ('snmp','voltage','39','.7','apEnvMonVoltageStatusIndex.7','acmepacket','3.3V Aux voltage (millivolts)','1000','1','3.75245','2.77355','3.263')[0m]
  1152. ( 1062 inserted )
  1153. +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','1062','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.7 3.3V Aux voltage (millivolts)','')[0m]
  1154. Array
  1155. (
  1156.     [acmepacket] => Array
  1157.         (
  1158.             [apEnvMonVoltageStatusIndex.1] => 1
  1159.             [apEnvMonVoltageStatusIndex.2] => 1
  1160.             [apEnvMonVoltageStatusIndex.3] => 1
  1161.             [apEnvMonVoltageStatusIndex.4] => 1
  1162.             [apEnvMonVoltageStatusIndex.5] => 1
  1163.             [apEnvMonVoltageStatusIndex.6] => 1
  1164.             [apEnvMonVoltageStatusIndex.7] => 1
  1165.         )
  1166.  
  1167. )
  1168. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1169. apEnvMonVoltageStatusIndex.1 -> acmepacket
  1170. apEnvMonVoltageStatusIndex.2 -> acmepacket
  1171. apEnvMonVoltageStatusIndex.3 -> acmepacket
  1172. apEnvMonVoltageStatusIndex.4 -> acmepacket
  1173. apEnvMonVoltageStatusIndex.5 -> acmepacket
  1174. apEnvMonVoltageStatusIndex.6 -> acmepacket
  1175. apEnvMonVoltageStatusIndex.7 -> acmepacket
  1176.  
  1177. Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1178.  
  1179. Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1180.  
  1181. Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1182.  
  1183. Delay: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1184.  
  1185. Quality_factor: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1186.  
  1187. Chromatic_dispersion: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1188.  
  1189. Ber: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1190.  
  1191. Eer: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1192.  
  1193. Waterflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  1194.  
  1195.  
  1196. >> Runtime for discovery module 'sensors': 0.1460 seconds with 32000 bytes
  1197. >> SNMP: [6/0.11s] MySQL: [97/0.03s] RRD: [0/0.00s]
  1198. #### Unload disco module sensors ####
  1199.  
  1200. Modules status: Global+ OS+ Device  
  1201. #### Load disco module storage ####
  1202. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m]
  1203. hrStorageEntry = No Such Object available on this agent at this OID
  1204.  
  1205. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dskTable[0m]
  1206. dskTable = No Such Object available on this agent at this OID
  1207.  
  1208. SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '39' AND `storage_type` != 'dsk'[0m]
  1209. SQL[[0;33mSELECT * FROM `storage` WHERE `device_id`  = '39'[0m]
  1210.  
  1211.  
  1212. >> Runtime for discovery module 'storage': 0.0380 seconds with 8376 bytes
  1213. >> SNMP: [2/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s]
  1214. #### Unload disco module storage ####
  1215.  
  1216. Modules status: Global+ OS+ Device  
  1217. #### Load disco module hr-device ####
  1218. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrDeviceEntry[0m]
  1219. hrDeviceEntry = No Such Object available on this agent at this OID
  1220.  
  1221. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrProcessorEntry[0m]
  1222. hrProcessorEntry = No Such Object available on this agent at this OID
  1223.  
  1224. Array
  1225. (
  1226. )
  1227. SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '39'[0m]
  1228.  
  1229.  
  1230. >> Runtime for discovery module 'hr-device': 0.0330 seconds with 3704 bytes
  1231. >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
  1232. #### Unload disco module hr-device ####
  1233.  
  1234. Modules status: Global+ OS+ Device  
  1235. #### Load disco module discovery-protocols ####
  1236.  CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 cdpCache[0m]
  1237. cdpCache = No Such Object available on this agent at this OID
  1238.  
  1239.  
  1240.  LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 lldpRemTable[0m]
  1241. lldpRemTable = No Such Object available on this agent at this OID
  1242.  
  1243.  
  1244.  OSPF Discovery: SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='39'[0m]
  1245.  
  1246. SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '39'[0m]
  1247. SQL[[0;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL[0m]
  1248.  0 orphaned links deleted
  1249.  
  1250. >> Runtime for discovery module 'discovery-protocols': 0.0440 seconds with 4848 bytes
  1251. >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
  1252. #### Unload disco module discovery-protocols ####
  1253.  
  1254. Modules status: Global+ OS+ Device  
  1255. #### Load disco module arp-table ####
  1256. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
  1257. ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  1258.  
  1259. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
  1260. ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
  1261.  
  1262. SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='39' AND `context_name`=''[0m]
  1263. SQL[[0;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL[0m]
  1264.  
  1265.  
  1266. >> Runtime for discovery module 'arp-table': 0.0590 seconds with 2360 bytes
  1267. >> SNMP: [0/0.00s] MySQL: [2/0.02s] RRD: [0/0.00s]
  1268. #### Unload disco module arp-table ####
  1269.  
  1270. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  1271.  
  1272. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  1273.  
  1274. Modules status: Global+ OS+ Device  
  1275. #### Load disco module bgp-peers ####
  1276. SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 bgpLocalAs[0m]
  1277. "M0"
  1278.  
  1279. No BGP on hostPeers :
  1280. SQL[[0;33mDELETE FROM `bgpPeers` WHERE device_id='39' AND context_name=''[0m]
  1281. SQL[[0;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id='39' AND context_name=''[0m]
  1282.  
  1283. SQL[[0;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id='39'[0m]
  1284.  
  1285. >> Runtime for discovery module 'bgp-peers': 0.0150 seconds with 5456 bytes
  1286. >> SNMP: [1/0.01s] MySQL: [3/0.00s] RRD: [0/0.00s]
  1287. #### Unload disco module bgp-peers ####
  1288.  
  1289. Modules status: Global+ OS+ Device  
  1290. #### Load disco module vlans ####
  1291. SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '39'[0m]
  1292. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
  1293. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  1294.  
  1295. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
  1296. No Such Object available on this agent at this OID
  1297.  
  1298.  
  1299.  
  1300. >> Runtime for discovery module 'vlans': 0.0460 seconds with 9296 bytes
  1301. >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
  1302. #### Unload disco module vlans ####
  1303.  
  1304. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  1305.  
  1306. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  1307.  
  1308. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  1309.  
  1310. Modules status: Global+ OS+ Device  
  1311. #### Load disco module ucd-diskio ####
  1312. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 diskIOEntry[0m]
  1313. diskIOEntry = No Such Object available on this agent at this OID
  1314.  
  1315. Array
  1316. (
  1317. )
  1318. SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id`  = '39'[0m]
  1319.  
  1320.  
  1321. >> Runtime for discovery module 'ucd-diskio': 0.0150 seconds with 3120 bytes
  1322. >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
  1323. #### Unload disco module ucd-diskio ####
  1324.  
  1325. Modules status: Global- OS- Device+
  1326. #### Load disco module applications ####
  1327.  
  1328. Applications: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 nsExtendStatus[0m]
  1329. nsExtendStatus = No Such Object available on this agent at this OID
  1330.  
  1331.  
  1332. Available:
  1333. Checking for:
  1334. SQL[[0;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='39' ORDER BY `app_type`[0m]
  1335. SQL[[0;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL[0m]
  1336.  
  1337.  
  1338. >> Runtime for discovery module 'applications': 0.0240 seconds with 4752 bytes
  1339. >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
  1340. #### Unload disco module applications ####
  1341.  
  1342. Modules status: Global+ OS+ Device  
  1343. #### Load disco module services ####
  1344.  
  1345. >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
  1346. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  1347. #### Unload disco module services ####
  1348.  
  1349. Modules status: Global+ OS+ Device  
  1350. #### Load disco module stp ####
  1351. SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '39'[0m]
  1352. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
  1353. No Such Object available on this agent at this OID
  1354.  
  1355.  
  1356.  
  1357. >> Runtime for discovery module 'stp': 0.0170 seconds with 5712 bytes
  1358. >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
  1359. #### Unload disco module stp ####
  1360.  
  1361. Modules status: Global+ OS+ Device- Module [ ntp ] disabled on host.
  1362.  
  1363. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  1364.  
  1365. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  1366.  
  1367. Modules status: Global+ OS+ Device- Module [ wireless ] disabled on host.
  1368.  
  1369. Modules status: Global+ OS+ Device  
  1370. #### Load disco module fdb-table ####
  1371. SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '39'[0m]
  1372. SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '39'[0m]
  1373. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qTpFdbPort[0m]
  1374. dot1qTpFdbPort = No Such Object available on this agent at this OID
  1375.  
  1376. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dTpFdbPort[0m]
  1377. dot1dTpFdbPort = No Such Object available on this agent at this OID
  1378.  
  1379.  
  1380.  
  1381. >> Runtime for discovery module 'fdb-table': 0.0410 seconds with 3032 bytes
  1382. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  1383. #### Unload disco module fdb-table ####
  1384.  
  1385. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
  1386. SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.119' WHERE `device_id` = '39'[0m]
  1387. Discovered in 6.119 seconds
  1388.  
  1389. SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','39','1526081733.504','6.279','1','librenms')[0m]
  1390. ./discovery.php 39 2018-05-11 23:35:39 - 1 devices discovered in 6.279 secs
  1391. SNMP [165/4.08s]: Get[133/3.35s] Getnext[1/0.01s] Walk[31/0.71s]
  1392. MySQL [1057/0.85s]: Cell[675/0.44s] Row[11/0.00s] Rows[52/0.03s] Column[2/0.00s] Update[270/0.34s] Insert[41/0.01s] Delete[6/0.02s]
  1393. RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]
  1394.