LibreNMS Discovery =================================== Version info: Commit SHA: 3e9f4b396e504627d8aae5f513c65f536fcf01ee Commit Date: 1526058363 DB Schema: 249 PHP: 7.2.5 MySQL: 5.7.21-21 RRDTool: 1.6.0 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! Updating os_def.cache... Done SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `device_id` = '39' ORDER BY device_id DESC[0m] SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '39'[0m] acme01 39 acmepacket SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.18','0.20','0.18','39',NOW())[0m] SNMP Check response code: 0 SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m] Attempting to initialize OS: acmepacket Attempting to initialize OS: oracle OS initilized as Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m] .*.*.0 = acme01 .*.*.0 = .*.4.1.9* .*.*.0 = Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) >> Runtime for discovery module 'core': 0.0140 seconds with 1088 bytes >> SNMP: [2/0.32s] MySQL: [8/0.00s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.9* | Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) | .1.3.6.1.4.1.9148.1.1.2 | OS: Acme Packet (acmepacket) >> Runtime for discovery module 'os': 0.6350 seconds with 1312 bytes >> SNMP: [2/0.64s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = eth0 ETH ifDescr.2 = lo0 ifDescr.5 = M0 GE ifDescr.6 = GE ifDescr.7 = M1 GE ifDescr.8 = GE ifDescr.13 = sp0 ETH SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifName[0m] ifName.5 = M0 ifName.6 = ifName.7 = M1 ifName.8 = SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifAlias[0m] ifAlias.5 = ifAlias.6 = ifAlias.7 = ifAlias.8 = SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifType[0m] ifType.1 = ethernetCsmacd ifType.2 = softwareLoopback ifType.5 = gigabitEthernet ifType.6 = gigabitEthernet ifType.7 = gigabitEthernet ifType.8 = gigabitEthernet ifType.13 = ethernetCsmacd Array ( [1] => Array ( [ifDescr] => eth0 ETH [ifType] => ethernetCsmacd ) [2] => Array ( [ifDescr] => lo0 [ifType] => softwareLoopback ) [5] => Array ( [ifDescr] => M0 GE [ifName] => M0 [ifAlias] => [ifType] => gigabitEthernet ) [6] => Array ( [ifDescr] => GE [ifName] => [ifAlias] => [ifType] => gigabitEthernet ) [7] => Array ( [ifDescr] => M1 GE [ifName] => M1 [ifAlias] => [ifType] => gigabitEthernet ) [8] => Array ( [ifDescr] => GE [ifName] => [ifAlias] => [ifType] => gigabitEthernet ) [13] => Array ( [ifDescr] => sp0 ETH [ifType] => ethernetCsmacd ) ) SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '39' ORDER BY port_id[0m] ....... >> Runtime for discovery module 'ports': 0.0660 seconds with 4216 bytes >> SNMP: [4/0.06s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '39'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ifStackStatus[0m] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0180 seconds with 1768 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalDescr.1 = Assy, NetNet4500 entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply entPhysicalDescr.4 = Assy, 4-fan unit entPhysicalDescr.5 = PHY Slot entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper entPhysicalDescr.10 = Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0 entPhysicalDescr.11 = Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1 entPhysicalDescr.12 = Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0 entPhysicalDescr.13 = Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1 entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module entPhysicalDescr.19 = TLS Hardware Accelerator entPhysicalVendorType.1 = enterprises.9*.3.2.5 entPhysicalVendorType.2 = enterprises.9*.5.3 entPhysicalVendorType.3 = enterprises.9*.5.3 entPhysicalVendorType.4 = enterprises.9*.6.3 entPhysicalVendorType.5 = enterprises.9*.4.2.2 entPhysicalVendorType.6 = enterprises.9*.8.2.12 entPhysicalVendorType.7 = enterprises.9*.9.3 entPhysicalVendorType.8 = enterprises.9*.9.3 entPhysicalVendorType.9 = enterprises.9*.9.3 entPhysicalVendorType.10 = enterprises.9*.9.2 entPhysicalVendorType.11 = enterprises.9*.9.2 entPhysicalVendorType.12 = enterprises.9*.9.2 entPhysicalVendorType.13 = enterprises.9*.9.2 entPhysicalVendorType.18 = enterprises.9*.8.4.7 entPhysicalVendorType.19 = enterprises.9*.8.8.6 entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 1 entPhysicalContainedIn.4 = 1 entPhysicalContainedIn.5 = 1 entPhysicalContainedIn.6 = 5 entPhysicalContainedIn.7 = 6 entPhysicalContainedIn.8 = 6 entPhysicalContainedIn.9 = 6 entPhysicalContainedIn.10 = 6 entPhysicalContainedIn.11 = 6 entPhysicalContainedIn.12 = 6 entPhysicalContainedIn.13 = 6 entPhysicalContainedIn.18 = 1 entPhysicalContainedIn.19 = 1 entPhysicalClass.1 = chassis entPhysicalClass.2 = powerSupply entPhysicalClass.3 = powerSupply entPhysicalClass.4 = fan entPhysicalClass.5 = container entPhysicalClass.6 = module entPhysicalClass.7 = port entPhysicalClass.8 = port entPhysicalClass.9 = port entPhysicalClass.10 = port entPhysicalClass.11 = port entPhysicalClass.12 = port entPhysicalClass.13 = port entPhysicalClass.18 = module entPhysicalClass.19 = module entPhysicalParentRelPos.1 = 0 entPhysicalParentRelPos.2 = 1 entPhysicalParentRelPos.3 = 2 entPhysicalParentRelPos.4 = 3 entPhysicalParentRelPos.5 = 4 entPhysicalParentRelPos.6 = 1 entPhysicalParentRelPos.7 = 1 entPhysicalParentRelPos.8 = 2 entPhysicalParentRelPos.9 = 3 entPhysicalParentRelPos.10 = 1 entPhysicalParentRelPos.11 = 2 entPhysicalParentRelPos.12 = 3 entPhysicalParentRelPos.13 = 4 entPhysicalParentRelPos.18 = 5 entPhysicalParentRelPos.19 = 7 entPhysicalName.1 = Main Board entPhysicalName.2 = Power Supply A entPhysicalName.3 = Power Supply B entPhysicalName.4 = 4-Fan unit entPhysicalName.5 = PHY Slot entPhysicalName.6 = Quad port GiGE SFP PHY entPhysicalName.7 = Mgmt0 entPhysicalName.8 = Mgmt1 entPhysicalName.9 = Mgmt2 entPhysicalName.10 = M0 entPhysicalName.11 = M1 entPhysicalName.12 = entPhysicalName.13 = entPhysicalName.18 = Host CPU Processor entPhysicalName.19 = BCM5823 entPhysicalHardwareRev.1 = 5.10 entPhysicalHardwareRev.2 = entPhysicalHardwareRev.3 = entPhysicalHardwareRev.4 = entPhysicalHardwareRev.5 = entPhysicalHardwareRev.6 = 4.11 entPhysicalHardwareRev.7 = entPhysicalHardwareRev.8 = entPhysicalHardwareRev.9 = entPhysicalHardwareRev.10 = entPhysicalHardwareRev.11 = entPhysicalHardwareRev.12 = entPhysicalHardwareRev.13 = entPhysicalHardwareRev.18 = entPhysicalHardwareRev.19 = 1 entPhysicalFirmwareRev.1 = entPhysicalFirmwareRev.2 = entPhysicalFirmwareRev.3 = entPhysicalFirmwareRev.4 = entPhysicalFirmwareRev.5 = entPhysicalFirmwareRev.6 = entPhysicalFirmwareRev.7 = entPhysicalFirmwareRev.8 = entPhysicalFirmwareRev.9 = entPhysicalFirmwareRev.10 = entPhysicalFirmwareRev.11 = entPhysicalFirmwareRev.12 = entPhysicalFirmwareRev.13 = entPhysicalFirmwareRev.18 = entPhysicalFirmwareRev.19 = entPhysicalSoftwareRev.1 = entPhysicalSoftwareRev.2 = entPhysicalSoftwareRev.3 = entPhysicalSoftwareRev.4 = entPhysicalSoftwareRev.5 = entPhysicalSoftwareRev.6 = entPhysicalSoftwareRev.7 = entPhysicalSoftwareRev.8 = entPhysicalSoftwareRev.9 = entPhysicalSoftwareRev.10 = entPhysicalSoftwareRev.11 = entPhysicalSoftwareRev.12 = entPhysicalSoftwareRev.13 = entPhysicalSoftwareRev.18 = entPhysicalSoftwareRev.19 = entPhysicalSerialNum.1 = entPhysicalSerialNum.2 = entPhysicalSerialNum.3 = entPhysicalSerialNum.4 = entPhysicalSerialNum.5 = entPhysicalSerialNum.6 = entPhysicalSerialNum.7 = entPhysicalSerialNum.8 = entPhysicalSerialNum.9 = entPhysicalSerialNum.10 = entPhysicalSerialNum.11 = entPhysicalSerialNum.12 = entPhysicalSerialNum.13 = entPhysicalSerialNum.18 = entPhysicalSerialNum.19 = entPhysicalMfgName.1 = Unknown manufacturer entPhysicalMfgName.2 = entPhysicalMfgName.3 = entPhysicalMfgName.4 = entPhysicalMfgName.5 = entPhysicalMfgName.6 = Benchmark Electronics entPhysicalMfgName.7 = entPhysicalMfgName.8 = entPhysicalMfgName.9 = entPhysicalMfgName.10 = entPhysicalMfgName.11 = entPhysicalMfgName.12 = entPhysicalMfgName.13 = entPhysicalMfgName.18 = entPhysicalMfgName.19 = BROADCOM entPhysicalModelName.1 = 002-0610-50 entPhysicalModelName.2 = entPhysicalModelName.3 = entPhysicalModelName.4 = entPhysicalModelName.5 = entPhysicalModelName.6 = 002-0613-58 entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.18 = entPhysicalModelName.19 = BCM5823 entPhysicalAlias.1 = entPhysicalAlias.2 = entPhysicalAlias.3 = entPhysicalAlias.4 = entPhysicalAlias.5 = entPhysicalAlias.6 = entPhysicalAlias.7 = entPhysicalAlias.8 = entPhysicalAlias.9 = entPhysicalAlias.10 = entPhysicalAlias.11 = entPhysicalAlias.12 = entPhysicalAlias.13 = entPhysicalAlias.18 = entPhysicalAlias.19 = entPhysicalAssetID.1 = entPhysicalAssetID.2 = entPhysicalAssetID.3 = entPhysicalAssetID.4 = entPhysicalAssetID.5 = entPhysicalAssetID.6 = entPhysicalAssetID.7 = entPhysicalAssetID.8 = entPhysicalAssetID.9 = entPhysicalAssetID.10 = entPhysicalAssetID.11 = entPhysicalAssetID.12 = entPhysicalAssetID.13 = entPhysicalAssetID.18 = entPhysicalAssetID.19 = entPhysicalIsFRU.1 = false entPhysicalIsFRU.2 = true entPhysicalIsFRU.3 = true entPhysicalIsFRU.4 = true entPhysicalIsFRU.5 = false entPhysicalIsFRU.6 = true entPhysicalIsFRU.7 = false entPhysicalIsFRU.8 = false entPhysicalIsFRU.9 = false entPhysicalIsFRU.10 = true entPhysicalIsFRU.11 = true entPhysicalIsFRU.12 = true entPhysicalIsFRU.13 = true entPhysicalIsFRU.18 = false entPhysicalIsFRU.19 = true entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '1'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='Assy, NetNet4500',`entPhysicalClass` ='chassis',`entPhysicalName` ='Main Board',`entPhysicalModelName` ='002-0610-50',`entPhysicalSerialNum` ='151330035903',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Unknown manufacturer',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='enterprises.9148.6.1.1.3.2.5',`entPhysicalHardwareRev` ='5.10',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='1'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '2'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply A',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='2'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '3'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='3',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply B',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='3'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '4'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='4',`entPhysicalDescr` ='Assy, 4-fan unit',`entPhysicalClass` ='fan',`entPhysicalName` ='4-Fan unit',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.6.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='4'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '5'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='5',`entPhysicalDescr` ='PHY Slot',`entPhysicalClass` ='container',`entPhysicalName` ='PHY Slot',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.4.2.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='5'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '6'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='6',`entPhysicalDescr` ='Assy, 4 Port SFP with QOS and IPSec',`entPhysicalClass` ='module',`entPhysicalName` ='Quad port GiGE SFP PHY',`entPhysicalModelName` ='002-0613-58',`entPhysicalSerialNum` ='091128054782',`entPhysicalContainedIn` ='5',`entPhysicalMfgName` ='Benchmark Electronics',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.2.12',`entPhysicalHardwareRev` ='4.11',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='6'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '7'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='7',`entPhysicalDescr` ='Management Port 0 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='7'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '8'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='8',`entPhysicalDescr` ='Management Port 1 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='8'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '9'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='9',`entPhysicalDescr` ='Management Port 2 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt2',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='9'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '10'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='10',`entPhysicalDescr` ='Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='M0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='10'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '11'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='11',`entPhysicalDescr` ='Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='M1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='11'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '12'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='12',`entPhysicalDescr` ='Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='12'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '13'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='13',`entPhysicalDescr` ='Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='13'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '18'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='18',`entPhysicalDescr` ='Intel Pentium Core 2 Duo Module',`entPhysicalClass` ='module',`entPhysicalName` ='Host CPU Processor',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='5',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.4.7',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='18'[0m] .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '19'[0m] SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='19',`entPhysicalDescr` ='TLS Hardware Accelerator',`entPhysicalClass` ='module',`entPhysicalName` ='BCM5823',`entPhysicalModelName` ='BCM5823',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='BROADCOM',`entPhysicalParentRelPos` ='7',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.8.6',`entPhysicalHardwareRev` ='1',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='19'[0m] . SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '39'[0m] >> Runtime for discovery module 'entity-physical': 0.1700 seconds with 9744 bytes >> SNMP: [1/0.14s] MySQL: [31/0.01s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device- Module [ entity-state ] disabled on host. Modules status: Global+ OS+ Device #### Load disco module processors #### Caching data: sensors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonCpuCoreTable[0m] apEnvMonCpuCoreTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPhyCardStatusTable[0m] apEnvMonPhyCardStatusType.1 = 0 apEnvMonPhyCardStatusDescr.1 = "Phy" apEnvMonPhyCardState.1 = 2 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonPowerSupplyStatusTable[0m] apEnvMonPowerSupplyStatusType.1 = 1 apEnvMonPowerSupplyStatusType.2 = 0 apEnvMonPowerSupplyStatusDescr.1 = "Power Supply A" apEnvMonPowerSupplyStatusDescr.2 = "Power Supply B" apEnvMonPowerSupplyState.1 = 2 apEnvMonPowerSupplyState.2 = 2 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonFanStatusTable[0m] apEnvMonFanStatusType.1 = 11 apEnvMonFanStatusType.2 = 12 apEnvMonFanStatusType.3 = 13 apEnvMonFanStatusType.4 = 14 apEnvMonFanStatusDescr.1 = "Fan 1 Speed" apEnvMonFanStatusDescr.2 = "Fan 2 Speed" apEnvMonFanStatusDescr.3 = "Fan 3 Speed" apEnvMonFanStatusDescr.4 = "Fan 4 Speed" apEnvMonFanStatusValue.1 = 100 apEnvMonFanStatusValue.2 = 100 apEnvMonFanStatusValue.3 = 100 apEnvMonFanStatusValue.4 = 100 apEnvMonFanState.1 = 2 apEnvMonFanState.2 = 2 apEnvMonFanState.3 = 2 apEnvMonFanState.4 = 2 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonTemperatureStatusTable[0m] apEnvMonTemperatureStatusType.1 = 6 apEnvMonTemperatureStatusType.2 = 5 apEnvMonTemperatureStatusType.3 = 4 apEnvMonTemperatureStatusType.4 = 7 apEnvMonTemperatureStatusDescr.1 = "CPU Temperature (degrees Celsius)" apEnvMonTemperatureStatusDescr.2 = "Main Board Temperature 0 (degrees Celcius)" apEnvMonTemperatureStatusDescr.3 = "Main Board Temperature 1 (degrees Celcius)" apEnvMonTemperatureStatusDescr.4 = "PHY Temperature 0 (degrees Celcius)" apEnvMonTemperatureStatusValue.1 = 45 apEnvMonTemperatureStatusValue.2 = 31 apEnvMonTemperatureStatusValue.3 = 28 apEnvMonTemperatureStatusValue.4 = 43 apEnvMonTemperatureState.1 = 2 apEnvMonTemperatureState.2 = 2 apEnvMonTemperatureState.3 = 2 apEnvMonTemperatureState.4 = 2 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apEnvMonVoltageStatusTable[0m] apEnvMonVoltageStatusType.1 = 8 apEnvMonVoltageStatusType.2 = 12 apEnvMonVoltageStatusType.3 = 13 apEnvMonVoltageStatusType.4 = 1 apEnvMonVoltageStatusType.5 = 2 apEnvMonVoltageStatusType.6 = 3 apEnvMonVoltageStatusType.7 = 15 apEnvMonVoltageStatusDescr.1 = "1.2V voltage (millivolts)" apEnvMonVoltageStatusDescr.2 = "1.5V voltage (millivolts)" apEnvMonVoltageStatusDescr.3 = "1.8V voltage (millivolts)" apEnvMonVoltageStatusDescr.4 = "2.5V voltage (millivolts)" apEnvMonVoltageStatusDescr.5 = "3.3V voltage (millivolts)" apEnvMonVoltageStatusDescr.6 = "5.0V voltage (millivolts)" apEnvMonVoltageStatusDescr.7 = "3.3V Aux voltage (millivolts)" apEnvMonVoltageStatusValue.1 = 1205 apEnvMonVoltageStatusValue.2 = 1493 apEnvMonVoltageStatusValue.3 = 1794 apEnvMonVoltageStatusValue.4 = 2483 apEnvMonVoltageStatusValue.5 = 3288 apEnvMonVoltageStatusValue.6 = 5058 apEnvMonVoltageStatusValue.7 = 3263 apEnvMonVoltageState.1 = 2 apEnvMonVoltageState.2 = 2 apEnvMonVoltageState.3 = 2 apEnvMonVoltageState.4 = 2 apEnvMonVoltageState.5 = 2 apEnvMonVoltageState.6 = 2 apEnvMonVoltageState.7 = 2 processors SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OteQUs -Ih -m ACMEPACKET-ENVMON-MIB:APSYSMGMT-MIB:ACMEPACKET-SMI:APLICENSE-MIB:ACMEPACKET-TC -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 apSysCPUUtil[0m] apSysCPUUtil.0 = 35 YAML Discovery Data: Array ( [data] => Array ( [0] => Array ( [oid] => apSysCPUUtil [num_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1 [type] => acmepacket ) ) ) Data apSysCPUUtil: Array ( [0] => Array ( [apSysCPUUtil] => 35 ) ) Discovered LibreNMS\Device\Processor Array ( [processor_id] => [entPhysicalIndex] => 0 [hrDeviceIndex] => 0 [device_id] => 39 [processor_oid] => .1.3.6.1.4.1.9148.3.2.1.1.1 [processor_index] => 0 [processor_type] => acmepacket [processor_usage] => 35 [processor_descr] => Processor [processor_precision] => 1 [processor_perc_warn] => 75 ) SQL[[0;33mSELECT * FROM `processors` WHERE device_id='39' AND processor_index='0' AND processor_type='acmepacket'[0m] .SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`='39' AND `processor_id` NOT IN ('761')[0m] SQL[[0;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL[0m] >> Runtime for discovery module 'processors': 0.1460 seconds with 180008 bytes >> SNMP: [7/0.14s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '39' AND `mempool_type` = 'cemp'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '39'[0m] >> Runtime for discovery module 'mempools': 0.0700 seconds with 41872 bytes >> SNMP: [3/0.07s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '39' [0m] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2640 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 5 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '39' AND `ifIndex` = '5'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '39' AND `ifIndex` = '5'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = 'x.x.x.x/24'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542'[0m] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m] * >> Runtime for discovery module 'ipv4-addresses': 3.1630 seconds with 36792 bytes >> SNMP: [128/2.38s] MySQL: [890/0.78s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '39' OR `ports`.`device_id` IS NULL[0m] >> Runtime for discovery module 'ipv6-addresses': 0.0330 seconds with 1376 bytes >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr.1 = Assy, NetNet4500 entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply entPhysicalDescr.4 = Assy, 4-fan unit entPhysicalDescr.5 = PHY Slot entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper entPhysicalDescr.10 = Media port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0 entPhysicalDescr.11 = Media port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1 entPhysicalDescr.12 = Media port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0 entPhysicalDescr.13 = Media port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1 entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module entPhysicalDescr.19 = TLS Hardware Accelerator entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName.1 = Main Board entPhysicalName.2 = Power Supply A entPhysicalName.3 = Power Supply B entPhysicalName.4 = 4-Fan unit entPhysicalName.5 = PHY Slot entPhysicalName.6 = Quad port GiGE SFP PHY entPhysicalName.7 = Mgmt0 entPhysicalName.8 = Mgmt1 entPhysicalName.9 = Mgmt2 entPhysicalName.10 = M0 entPhysicalName.11 = M1 entPhysicalName.12 = entPhysicalName.13 = entPhysicalName.18 = Host CPU Processor entPhysicalName.19 = BCM5823 entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'ipmi_hostname' [0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m] Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Fanspeed: Dynamic Discovery (fanspeed): Array ( [data] => Array ( [0] => Array ( [oid] => apEnvMonFanStatusTable [value] => apEnvMonFanStatusValue [num_oid] => . [descr] => apEnvMonFanStatusDescr [index] => apEnvMonFanStatusValue.{{ $index }} ) ) ) Data apEnvMonFanStatusTable: Array ( [1] => Array ( [apEnvMonFanStatusType] => 11 [apEnvMonFanStatusDescr] => Fan 1 Speed [apEnvMonFanStatusValue] => 100 [apEnvMonFanState] => 2 ) [2] => Array ( [apEnvMonFanStatusType] => 12 [apEnvMonFanStatusDescr] => Fan 2 Speed [apEnvMonFanStatusValue] => 100 [apEnvMonFanState] => 2 ) [3] => Array ( [apEnvMonFanStatusType] => 13 [apEnvMonFanStatusDescr] => Fan 3 Speed [apEnvMonFanStatusValue] => 100 [apEnvMonFanState] => 2 ) [4] => Array ( [apEnvMonFanStatusType] => 14 [apEnvMonFanStatusDescr] => Fan 4 Speed [apEnvMonFanStatusValue] => 100 [apEnvMonFanState] => 2 ) ) Final sensor value: 100 Cur 100, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1, apEnvMonFanStatusValue.1, acmepacket, Fan 1 Speed, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.1'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.1','apEnvMonFanStatusValue.1','acmepacket','Fan 1 Speed','1','1','180','80','100')[0m] ( 1045 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1045','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.1 Fan 1 Speed','')[0m] Final sensor value: 100 Cur 100, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .2, apEnvMonFanStatusValue.2, acmepacket, Fan 2 Speed, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.2'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.2','apEnvMonFanStatusValue.2','acmepacket','Fan 2 Speed','1','1','180','80','100')[0m] ( 1046 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1046','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.2 Fan 2 Speed','')[0m] Final sensor value: 100 Cur 100, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .3, apEnvMonFanStatusValue.3, acmepacket, Fan 3 Speed, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.3'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.3','apEnvMonFanStatusValue.3','acmepacket','Fan 3 Speed','1','1','180','80','100')[0m] ( 1047 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1047','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.3 Fan 3 Speed','')[0m] Final sensor value: 100 Cur 100, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .4, apEnvMonFanStatusValue.4, acmepacket, Fan 4 Speed, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonFanStatusValue.4'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','fanspeed','39','.4','apEnvMonFanStatusValue.4','acmepacket','Fan 4 Speed','1','1','180','80','100')[0m] ( 1048 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1048','sensor',NOW(),'3','Sensor Added: fanspeed acmepacket apEnvMonFanStatusValue.4 Fan 4 Speed','')[0m] Array ( [acmepacket] => Array ( [apEnvMonFanStatusValue.1] => 1 [apEnvMonFanStatusValue.2] => 1 [apEnvMonFanStatusValue.3] => 1 [apEnvMonFanStatusValue.4] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] apEnvMonFanStatusValue.1 -> acmepacket apEnvMonFanStatusValue.2 -> acmepacket apEnvMonFanStatusValue.3 -> acmepacket apEnvMonFanStatusValue.4 -> acmepacket Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Load: Dynamic Discovery (load): Array ( [data] => Array ( [0] => Array ( [oid] => apEnvMonCpuCoreTable [value] => apEnvMonCpuCoreUsage [num_oid] => . [descr] => apEnvMonCpuCoreDescr ) ) ) Data apEnvMonCpuCoreTable: Array ( ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] State: Dynamic Discovery (state): Array ( [data] => Array ( [0] => Array ( [oid] => apEnvMonPhyCardStatusTable [value] => apEnvMonPhyCardState [num_oid] => . [descr] => apEnvMonPhyCardStatusDescr ) [1] => Array ( [oid] => apEnvMonPowerSupplyStatusTable [value] => apEnvMonPowerSupplyState [num_oid] => . [descr] => apEnvMonPowerSupplyStatusDescr [index] => apEnvMonPowerSupplyStatusIndex.{{ $index }} ) ) ) Data apEnvMonPhyCardStatusTable: Array ( [1] => Array ( [apEnvMonPhyCardStatusType] => 0 [apEnvMonPhyCardStatusDescr] => Phy [apEnvMonPhyCardState] => 2 ) ) Final sensor value: 2 Cur 2, Low: null, Low Warn: null, Warn: null, High: null SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPhyCardStatusTable' LIMIT 1[0m] SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '21'[0m] Discover sensor: .1, 1, apEnvMonPhyCardStatusTable, Phy, snmp, 1, 1, , 2 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.1','1','apEnvMonPhyCardStatusTable','Phy','1','1','2')[0m] ( 1049 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1049','sensor',NOW(),'3','Sensor Added: state apEnvMonPhyCardStatusTable 1 Phy','')[0m] SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPhyCardStatusTable' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPhyCardStatusTable'[0m] SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1049','21')[0m] Data apEnvMonPowerSupplyStatusTable: Array ( [1] => Array ( [apEnvMonPowerSupplyStatusType] => 1 [apEnvMonPowerSupplyStatusDescr] => Power Supply A [apEnvMonPowerSupplyState] => 2 ) [2] => Array ( [apEnvMonPowerSupplyStatusType] => 0 [apEnvMonPowerSupplyStatusDescr] => Power Supply B [apEnvMonPowerSupplyState] => 2 ) ) Final sensor value: 2 Cur 2, Low: null, Low Warn: null, Warn: null, High: null SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m] SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m] Discover sensor: .1, apEnvMonPowerSupplyStatusIndex.1, apEnvMonPowerSupplyStatusTable, Power Supply A, snmp, 1, 1, , 2 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.1','apEnvMonPowerSupplyStatusIndex.1','apEnvMonPowerSupplyStatusTable','Power Supply A','1','1','2')[0m] ( 1050 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1050','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.1 Power Supply A','')[0m] SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.1'[0m] SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m] SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1050','22')[0m] Final sensor value: 2 Cur 2, Low: null, Low Warn: null, Warn: null, High: null SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'apEnvMonPowerSupplyStatusTable' LIMIT 1[0m] SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '22'[0m] Discover sensor: .2, apEnvMonPowerSupplyStatusIndex.2, apEnvMonPowerSupplyStatusTable, Power Supply B, snmp, 1, 1, , 2 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '39' AND sensor_type = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','39','.2','apEnvMonPowerSupplyStatusIndex.2','apEnvMonPowerSupplyStatusTable','Power Supply B','1','1','2')[0m] ( 1051 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1051','sensor',NOW(),'3','Sensor Added: state apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.2 Power Supply B','')[0m] SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '39' AND `sensor_type` = 'apEnvMonPowerSupplyStatusTable' AND `sensor_index` = 'apEnvMonPowerSupplyStatusIndex.2'[0m] SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'apEnvMonPowerSupplyStatusTable'[0m] SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('1051','22')[0m] Array ( [apEnvMonPhyCardStatusTable] => Array ( [1] => 1 ) [apEnvMonPowerSupplyStatusTable] => Array ( [apEnvMonPowerSupplyStatusIndex.1] => 1 [apEnvMonPowerSupplyStatusIndex.2] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] 1 -> apEnvMonPhyCardStatusTable apEnvMonPowerSupplyStatusIndex.1 -> apEnvMonPowerSupplyStatusTable apEnvMonPowerSupplyStatusIndex.2 -> apEnvMonPowerSupplyStatusTable Temperature: Dynamic Discovery (temperature): Array ( [data] => Array ( [0] => Array ( [oid] => apEnvMonTemperatureStatusTable [value] => apEnvMonTemperatureStatusValue [num_oid] => . [descr] => apEnvMonTemperatureStatusDescr [index] => apEnvMonTemperatureStatusIndex.{{ $index }} ) ) ) Data apEnvMonTemperatureStatusTable: Array ( [1] => Array ( [apEnvMonTemperatureStatusType] => 6 [apEnvMonTemperatureStatusDescr] => CPU Temperature (degrees Celsius) [apEnvMonTemperatureStatusValue] => 45 [apEnvMonTemperatureState] => 2 ) [2] => Array ( [apEnvMonTemperatureStatusType] => 5 [apEnvMonTemperatureStatusDescr] => Main Board Temperature 0 (degrees Celcius) [apEnvMonTemperatureStatusValue] => 31 [apEnvMonTemperatureState] => 2 ) [3] => Array ( [apEnvMonTemperatureStatusType] => 4 [apEnvMonTemperatureStatusDescr] => Main Board Temperature 1 (degrees Celcius) [apEnvMonTemperatureStatusValue] => 28 [apEnvMonTemperatureState] => 2 ) [4] => Array ( [apEnvMonTemperatureStatusType] => 7 [apEnvMonTemperatureStatusDescr] => PHY Temperature 0 (degrees Celcius) [apEnvMonTemperatureStatusValue] => 43 [apEnvMonTemperatureState] => 2 ) ) Final sensor value: 45 Cur 45, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1, apEnvMonTemperatureStatusIndex.1, acmepacket, CPU Temperature (degrees Celsius), snmp, 1, 1, , 45 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.1'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.1','apEnvMonTemperatureStatusIndex.1','acmepacket','CPU Temperature (degrees Celsius)','1','1','65','35','45')[0m] ( 1052 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1052','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.1 CPU Temperature (degrees Celsius)','')[0m] Final sensor value: 31 Cur 31, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .2, apEnvMonTemperatureStatusIndex.2, acmepacket, Main Board Temperature 0 (degrees Celcius), snmp, 1, 1, , 31 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.2'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.2','apEnvMonTemperatureStatusIndex.2','acmepacket','Main Board Temperature 0 (degrees Celcius)','1','1','51','21','31')[0m] ( 1053 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1053','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.2 Main Board Temperature 0 (degrees Celcius)','')[0m] Final sensor value: 28 Cur 28, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .3, apEnvMonTemperatureStatusIndex.3, acmepacket, Main Board Temperature 1 (degrees Celcius), snmp, 1, 1, , 28 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.3'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.3','apEnvMonTemperatureStatusIndex.3','acmepacket','Main Board Temperature 1 (degrees Celcius)','1','1','48','18','28')[0m] ( 1054 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1054','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.3 Main Board Temperature 1 (degrees Celcius)','')[0m] Final sensor value: 43 Cur 43, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .4, apEnvMonTemperatureStatusIndex.4, acmepacket, PHY Temperature 0 (degrees Celcius), snmp, 1, 1, , 43 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonTemperatureStatusIndex.4'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','temperature','39','.4','apEnvMonTemperatureStatusIndex.4','acmepacket','PHY Temperature 0 (degrees Celcius)','1','1','63','33','43')[0m] ( 1055 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1055','sensor',NOW(),'3','Sensor Added: temperature acmepacket apEnvMonTemperatureStatusIndex.4 PHY Temperature 0 (degrees Celcius)','')[0m] Array ( [acmepacket] => Array ( [apEnvMonTemperatureStatusIndex.1] => 1 [apEnvMonTemperatureStatusIndex.2] => 1 [apEnvMonTemperatureStatusIndex.3] => 1 [apEnvMonTemperatureStatusIndex.4] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] apEnvMonTemperatureStatusIndex.1 -> acmepacket apEnvMonTemperatureStatusIndex.2 -> acmepacket apEnvMonTemperatureStatusIndex.3 -> acmepacket apEnvMonTemperatureStatusIndex.4 -> acmepacket Voltage: Dynamic Discovery (voltage): Array ( [data] => Array ( [0] => Array ( [oid] => apEnvMonVoltageStatusTable [value] => apEnvMonVoltageStatusValue [num_oid] => . [descr] => apEnvMonVoltageStatusDescr [divisor] => 1000 [index] => apEnvMonVoltageStatusIndex.{{ $index }} ) ) ) Data apEnvMonVoltageStatusTable: Array ( [1] => Array ( [apEnvMonVoltageStatusType] => 8 [apEnvMonVoltageStatusDescr] => 1.2V voltage (millivolts) [apEnvMonVoltageStatusValue] => 1205 [apEnvMonVoltageState] => 2 ) [2] => Array ( [apEnvMonVoltageStatusType] => 12 [apEnvMonVoltageStatusDescr] => 1.5V voltage (millivolts) [apEnvMonVoltageStatusValue] => 1493 [apEnvMonVoltageState] => 2 ) [3] => Array ( [apEnvMonVoltageStatusType] => 13 [apEnvMonVoltageStatusDescr] => 1.8V voltage (millivolts) [apEnvMonVoltageStatusValue] => 1794 [apEnvMonVoltageState] => 2 ) [4] => Array ( [apEnvMonVoltageStatusType] => 1 [apEnvMonVoltageStatusDescr] => 2.5V voltage (millivolts) [apEnvMonVoltageStatusValue] => 2483 [apEnvMonVoltageState] => 2 ) [5] => Array ( [apEnvMonVoltageStatusType] => 2 [apEnvMonVoltageStatusDescr] => 3.3V voltage (millivolts) [apEnvMonVoltageStatusValue] => 3288 [apEnvMonVoltageState] => 2 ) [6] => Array ( [apEnvMonVoltageStatusType] => 3 [apEnvMonVoltageStatusDescr] => 5.0V voltage (millivolts) [apEnvMonVoltageStatusValue] => 5058 [apEnvMonVoltageState] => 2 ) [7] => Array ( [apEnvMonVoltageStatusType] => 15 [apEnvMonVoltageStatusDescr] => 3.3V Aux voltage (millivolts) [apEnvMonVoltageStatusValue] => 3263 [apEnvMonVoltageState] => 2 ) ) Final sensor value: 1205 Cur 1205, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1, apEnvMonVoltageStatusIndex.1, acmepacket, 1.2V voltage (millivolts), snmp, 1000, 1, , 1.205 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.1'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.1','apEnvMonVoltageStatusIndex.1','acmepacket','1.2V voltage (millivolts)','1000','1','1.38575','1.02425','1.205')[0m] ( 1056 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1056','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.1 1.2V voltage (millivolts)','')[0m] Final sensor value: 1493 Cur 1493, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .2, apEnvMonVoltageStatusIndex.2, acmepacket, 1.5V voltage (millivolts), snmp, 1000, 1, , 1.493 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.2'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.2','apEnvMonVoltageStatusIndex.2','acmepacket','1.5V voltage (millivolts)','1000','1','1.71695','1.26905','1.493')[0m] ( 1057 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1057','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.2 1.5V voltage (millivolts)','')[0m] Final sensor value: 1794 Cur 1794, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .3, apEnvMonVoltageStatusIndex.3, acmepacket, 1.8V voltage (millivolts), snmp, 1000, 1, , 1.794 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.3'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.3','apEnvMonVoltageStatusIndex.3','acmepacket','1.8V voltage (millivolts)','1000','1','2.0631','1.5249','1.794')[0m] ( 1058 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1058','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.3 1.8V voltage (millivolts)','')[0m] Final sensor value: 2483 Cur 2483, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .4, apEnvMonVoltageStatusIndex.4, acmepacket, 2.5V voltage (millivolts), snmp, 1000, 1, , 2.483 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.4'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.4','apEnvMonVoltageStatusIndex.4','acmepacket','2.5V voltage (millivolts)','1000','1','2.85545','2.11055','2.483')[0m] ( 1059 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1059','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.4 2.5V voltage (millivolts)','')[0m] Final sensor value: 3288 Cur 3288, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .5, apEnvMonVoltageStatusIndex.5, acmepacket, 3.3V voltage (millivolts), snmp, 1000, 1, , 3.288 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.5'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.5','apEnvMonVoltageStatusIndex.5','acmepacket','3.3V voltage (millivolts)','1000','1','3.7812','2.7948','3.288')[0m] ( 1060 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1060','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.5 3.3V voltage (millivolts)','')[0m] Final sensor value: 5058 Cur 5058, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .6, apEnvMonVoltageStatusIndex.6, acmepacket, 5.0V voltage (millivolts), snmp, 1000, 1, , 5.058 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.6'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.6','apEnvMonVoltageStatusIndex.6','acmepacket','5.0V voltage (millivolts)','1000','1','5.8167','4.2993','5.058')[0m] ( 1061 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1061','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.6 5.0V voltage (millivolts)','')[0m] Final sensor value: 3263 Cur 3263, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .7, apEnvMonVoltageStatusIndex.7, acmepacket, 3.3V Aux voltage (millivolts), snmp, 1000, 1, , 3.263 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '39' AND sensor_type = 'acmepacket' AND `sensor_index` = 'apEnvMonVoltageStatusIndex.7'[0m] SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_limit`,`sensor_limit_low`,`sensor_current`) VALUES ('snmp','voltage','39','.7','apEnvMonVoltageStatusIndex.7','acmepacket','3.3V Aux voltage (millivolts)','1000','1','3.75245','2.77355','3.263')[0m] ( 1062 inserted ) +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('39','39','1062','sensor',NOW(),'3','Sensor Added: voltage acmepacket apEnvMonVoltageStatusIndex.7 3.3V Aux voltage (millivolts)','')[0m] Array ( [acmepacket] => Array ( [apEnvMonVoltageStatusIndex.1] => 1 [apEnvMonVoltageStatusIndex.2] => 1 [apEnvMonVoltageStatusIndex.3] => 1 [apEnvMonVoltageStatusIndex.4] => 1 [apEnvMonVoltageStatusIndex.5] => 1 [apEnvMonVoltageStatusIndex.6] => 1 [apEnvMonVoltageStatusIndex.7] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] apEnvMonVoltageStatusIndex.1 -> acmepacket apEnvMonVoltageStatusIndex.2 -> acmepacket apEnvMonVoltageStatusIndex.3 -> acmepacket apEnvMonVoltageStatusIndex.4 -> acmepacket apEnvMonVoltageStatusIndex.5 -> acmepacket apEnvMonVoltageStatusIndex.6 -> acmepacket apEnvMonVoltageStatusIndex.7 -> acmepacket Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Delay: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Quality_factor: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Chromatic_dispersion: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Ber: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Eer: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] Waterflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m] >> Runtime for discovery module 'sensors': 0.1460 seconds with 32000 bytes >> SNMP: [6/0.11s] MySQL: [97/0.03s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '39' AND `storage_type` != 'dsk'[0m] SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '39'[0m] >> Runtime for discovery module 'storage': 0.0380 seconds with 8376 bytes >> SNMP: [2/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '39'[0m] >> Runtime for discovery module 'hr-device': 0.0330 seconds with 3704 bytes >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 lldpRemTable[0m] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='39'[0m] SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '39'[0m] SQL[[0;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL[0m] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.0440 seconds with 4848 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress = No Such Object available on this agent at this OID SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='39' AND `context_name`=''[0m] SQL[[0;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL[0m] >> Runtime for discovery module 'arp-table': 0.0590 seconds with 2360 bytes >> SNMP: [0/0.00s] MySQL: [2/0.02s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 bgpLocalAs[0m] "M0" No BGP on hostPeers : SQL[[0;33mDELETE FROM `bgpPeers` WHERE device_id='39' AND context_name=''[0m] SQL[[0;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id='39' AND context_name=''[0m] SQL[[0;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id='39'[0m] >> Runtime for discovery module 'bgp-peers': 0.0150 seconds with 5456 bytes >> SNMP: [1/0.01s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '39'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0460 seconds with 9296 bytes >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '39'[0m] >> Runtime for discovery module 'ucd-diskio': 0.0150 seconds with 3120 bytes >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device+ #### Load disco module applications #### Applications: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 nsExtendStatus[0m] nsExtendStatus = No Such Object available on this agent at this OID Available: Checking for: SQL[[0;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='39' ORDER BY `app_type`[0m] SQL[[0;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL[0m] >> Runtime for discovery module 'applications': 0.0240 seconds with 4752 bytes >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module applications #### Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '39'[0m] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0170 seconds with 5712 bytes >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device- Module [ ntp ] disabled on host. Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device- Module [ wireless ] disabled on host. Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '39'[0m] SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '39'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/oracle udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.0410 seconds with 3032 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m] SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.119' WHERE `device_id` = '39'[0m] Discovered in 6.119 seconds SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','39','1526081733.504','6.279','1','librenms')[0m] ./discovery.php 39 2018-05-11 23:35:39 - 1 devices discovered in 6.279 secs SNMP [165/4.08s]: Get[133/3.35s] Getnext[1/0.01s] Walk[31/0.71s] MySQL [1057/0.85s]: Cell[675/0.44s] Row[11/0.00s] Rows[52/0.03s] Column[2/0.00s] Update[270/0.34s] Insert[41/0.01s] Delete[6/0.02s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]