- WebGraph-2xThermometer-MIB DEFINITIONS ::= BEGIN
- ----------------------------------------------------------------
- -- Revison: 1.30
- ----------------------------------------------------------------
- -- 22.06.2010 Messwertausgabe mit Punkt als Trennzeichen
- --
- ----------------------------------------------------------------
- -- Revison: 1.28
- ----------------------------------------------------------------
- -- 19.01.2007 Webio
- -- New Graphics javascript base parameter
- ----------------------------------------------------------------
- -- Revison: 1.27
- ----------------------------------------------------------------
- -- 09.11.2006 Webio
- -- DHCP enable
- ----------------------------------------------------------------
- -- Revison: 1.25
- ----------------------------------------------------------------
- -- 28.06.2006 New: Community String Trap
- --
- ----------------------------------------------------------------
- -- Revison: 1.24
- ----------------------------------------------------------------
- -- 23.12.2005 #57607, WebGraph 2x Thermometer
- --
- IMPORTS
- OBJECT-TYPE FROM RFC-1212
- TRAP-TYPE FROM RFC-1215
- DisplayString, PhysAddress FROM RFC1213-MIB
- enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
- -- IpAddress ::=
- -- [APPLICATION 0]
- -- IMPLICIT OCTET STRING (SIZE (4))
- -- Counter ::=
- -- [APPLICATION 1]
- -- IMPLICIT INTEGER (0..4294967295)
- -- Gauge ::=
- -- [APPLICATION 2]
- -- IMPLICIT INTEGER (0..4294967295)
- -- TimeTicks ::=
- -- [APPLICATION 3]
- -- IMPLICIT INTEGER (0..4294967295)
- -- DisplayString ::= OCTET STRING
- -- PhysAddress ::= OCTET STRING
- -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
- -- privat OBJECT IDENTIFIER ::= { internet 4 }
- -- enterprises OBJECT IDENTIFIER ::= { privat 1 }
- -- Wiesemann & Theis Com-Server MIB
- wut OBJECT IDENTIFIER ::= { enterprises 5040 }
- wtComServer OBJECT IDENTIFIER ::= { wut 1 }
- wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
- -- wtWebio Tree
- wtWebioAn2Graph OBJECT IDENTIFIER ::= { wtWebio 7 }
- -- wtWebioAn2Graph Tree
- wtWebioAn2GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn2Graph 1 }
- wtWebioAn2GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn2Graph 2 }
- wtWebioAn2GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn2Graph 3 }
- wtWebioAn2GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn2Graph 4 }
- -- wtWebioAn2GraphConfig Tree
- wtWebioAn2GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 1 }
- wtWebioAn2GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 2 }
- wtWebioAn2GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 3 }
- -- wtWebioAn2GraphDevice Tree
- wtWebioAn2GraphText OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 1 }
- wtWebioAn2GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 2 }
- wtWebioAn2GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 3 }
- wtWebioAn2GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 4 }
- wtWebioAn2GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 5 }
- wtWebioAn2GraphGraphics OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 6 }
- -- wtWebioAn2GraphTimeDate Tree
- wtWebioAn2GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 1 }
- wtWebioAn2GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 2 }
- wtWebioAn2GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 3 }
- -- wtWebioAn2GraphBasic Tree
- wtWebioAn2GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 1 }
- wtWebioAn2GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 2 }
- wtWebioAn2GraphMail OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 3 }
- wtWebioAn2GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 4 }
- wtWebioAn2GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 5 }
- wtWebioAn2GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 6 }
- wtWebioAn2GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 7 }
- -- wtWebioAn2GraphGraphics Tree
- wtWebioAn2GraphGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 1 }
- wtWebioAn2GraphGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 2 }
- wtWebioAn2GraphGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 3 }
- -- wtWebioAn2GraphTemp Group
- ------------------------
- wtWebioAn2GraphSensors OBJECT-TYPE
- SYNTAX INTEGER (1..2)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Anzahl der Temperatursensoren"
- ::= { wtWebioAn2GraphTemp 1 }
- -- Interface Table
- wtWebioAn2GraphSensorTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphSensorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Sensoren."
- ::= { wtWebioAn2GraphTemp 2 }
- wtWebioAn2GraphSensorEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphSensorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Nummern der Temperatursensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphSensorTable 1 }
- wtWebioAn2GraphSensorEntry ::= SEQUENCE {
- wtWebioAn2GraphSensorNo INTEGER
- }
- wtWebioAn2GraphSensorNo OBJECT-TYPE
- SYNTAX INTEGER (1..2)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Nummer des Temperatursensors."
- ::= { wtWebioAn2GraphSensorEntry 1 }
- -- wtWebioAn2GraphTempValue Table
- wtWebioAn2GraphTempValueTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphTempValueEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste Temperaturwerte korrespondiernd zu den Kanalnummern."
- ::= { wtWebioAn2GraphTemp 3 }
- wtWebioAn2GraphTempValueEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphTempValueEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Temperaturen der Sensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphTempValueTable 1 }
- wtWebioAn2GraphTempValueEntry ::= SEQUENCE{
- wtWebioAn2GraphTempValue OCTET STRING
- }
- wtWebioAn2GraphTempValue OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (5))
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Temperaturwert des Sensors, ASCII, 5 Zeichen lang."
- ::= { wtWebioAn2GraphTempValueEntry 1 }
- -- wtWebioAn2GraphBinaryTempValue Table
- wtWebioAn2GraphBinaryTempValueTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphBinaryTempValueEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern."
- ::= { wtWebioAn2GraphTemp 4 }
- wtWebioAn2GraphBinaryTempValueEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphBinaryTempValueEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Binäre Temperaturen der Sensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphBinaryTempValueTable 1 }
- wtWebioAn2GraphBinaryTempValueEntry ::= SEQUENCE{
- wtWebioAn2GraphBinaryTempValue INTEGER
- }
- wtWebioAn2GraphBinaryTempValue OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Binärer Temperaturwert des Sensors in 1/10 Grad Celcius,
- vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen
- ungültigen Messwert an."
- ::= { wtWebioAn2GraphBinaryTempValueEntry 1 }
- -- wtWebioAn2GraphTempValuePkt Table
- wtWebioAn2GraphTempValuePktTable OBJECT-TYPE
- SYNTAX SEQUENCE OF WtWebioAn2GraphTempValuePktEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste Temperaturwerte korrespondiernd zu den Kanalnummern."
- ::= { wtWebioAn2GraphTemp 8 }
- wtWebioAn2GraphTempValuePktEntry OBJECT-TYPE
- SYNTAX WtWebioAn2GraphTempValuePktEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Temperaturen der Sensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphTempValuePktTable 1 }
- WtWebioAn2GraphTempValuePktEntry ::= SEQUENCE{
- wtWebioAn2GraphTempValuePkt OCTET STRING
- }
- wtWebioAn2GraphTempValuePkt OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (5))
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Temperaturwert des Sensors, ASCII, 5 Zeichen lang, dezimal Punkt."
- ::= { wtWebioAn2GraphTempValuePktEntry 1 }
- -- wtWebioAn2GraphSessCntrl Group
- --------------------------------
- wtWebioAn2GraphSessCntrlPassword OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1
- in wtWebioAn2GraphSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der
- Länge Null."
- ::= { wtWebioAn2GraphSessCntrl 1 }
- wtWebioAn2GraphSessCntrlConfigMode OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphSessCntrl-NoSession(0),
- wtWebioAn2GraphSessCntrl-Session(1)
- }
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert
- 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0
- obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits
- im Configmodus und die Variablen können nur gelesen werden."
- ::= { wtWebioAn2GraphSessCntrl 2 }
- wtWebioAn2GraphSessCntrlLogout OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde
- von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese
- Variable die Session beendet werden und alle Parameter werden gespeichert.
- Durch Schreiben einer 2 werden alle Eingaben wieder verworfen.
- Gelesen liefert diese Variable den Wert 0."
- ::= { wtWebioAn2GraphSessCntrl 3 }
- wtWebioAn2GraphSessCntrlAdminPassword OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom
- Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort.
- Gelesen liefert diese Variable einen Null-Pointer."
- ::= { wtWebioAn2GraphSessCntrl 4 }
- wtWebioAn2GraphSessCntrlConfigPassword OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom
- Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist
- public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer."
- ::= { wtWebioAn2GraphSessCntrl 5 }
- -- wtWebioAn2GraphText Group
- ------------------------
- wtWebioAn2GraphDeviceName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name des Webio's, der userdefinierbar ist."
- ::= { wtWebioAn2GraphText 1 }
- wtWebioAn2GraphDeviceText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Beschreibung des Webio's, die userdefinierbar ist."
- ::= { wtWebioAn2GraphText 2 }
- wtWebioAn2GraphDeviceLocation OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Aufstellort des Webio's, die userdefinierbar ist."
- ::= { wtWebioAn2GraphText 3 }
- wtWebioAn2GraphDeviceContact OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Kontactadresse im Servicefall des Webio's, die userdefinierbar ist."
- ::= { wtWebioAn2GraphText 4 }
- -- wtWebioAn2GraphTimeZone Group
- ----------------------------
- wtWebioAn2GraphTzOffsetHrs OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC."
- ::= { wtWebioAn2GraphTimeZone 1 }
- wtWebioAn2GraphTzOffsetMin OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC."
- ::= { wtWebioAn2GraphTimeZone 2 }
- wtWebioAn2GraphTzEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Bedingung:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Apply Timezone"
- ::= { wtWebioAn2GraphTimeZone 3 }
- wtWebioAn2GraphStTzOffsetHrs OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC."
- ::= { wtWebioAn2GraphTimeZone 4 }
- wtWebioAn2GraphStTzOffsetMin OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC."
- ::= { wtWebioAn2GraphTimeZone 5 }
- wtWebioAn2GraphStTzEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Bedingung:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Apply Summertime"
- ::= { wtWebioAn2GraphTimeZone 6 }
- wtWebioAn2GraphStTzStartMonth OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStartMonth-January(1),
- wtWebioAn2GraphStartMonth-February(2),
- wtWebioAn2GraphStartMonth-March(3),
- wtWebioAn2GraphStartMonth-April(4),
- wtWebioAn2GraphStartMonth-May(5),
- wtWebioAn2GraphStartMonth-June(6),
- wtWebioAn2GraphStartMonth-July(7),
- wtWebioAn2GraphStartMonth-August(8),
- wtWebioAn2GraphStartMonth-September(9),
- wtWebioAn2GraphStartMonth-October(10),
- wtWebioAn2GraphStartMonth-November(11),
- wtWebioAn2GraphStartMonth-December(12)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 7 }
- wtWebioAn2GraphStTzStartMode OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStartMode-first(1),
- wtWebioAn2GraphStartMode-second(2),
- wtWebioAn2GraphStartMode-third(3),
- wtWebioAn2GraphStartMode-fourth(4),
- wtWebioAn2GraphStartMode-last(5)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 8 }
- wtWebioAn2GraphStTzStartWday OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStartWday-Sunday(1),
- wtWebioAn2GraphStartWday-Monday(2),
- wtWebioAn2GraphStartWday-Tuesday(3),
- wtWebioAn2GraphStartWday-Thursday(4),
- wtWebioAn2GraphStartWday-Wednesday(5),
- wtWebioAn2GraphStartWday-Friday(6),
- wtWebioAn2GraphStartWday-Saturday(7)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird"
- ::= { wtWebioAn2GraphTimeZone 9 }
- wtWebioAn2GraphStTzStartHrs OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
- umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 10 }
- wtWebioAn2GraphStTzStartMin OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC
- umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 11 }
- wtWebioAn2GraphStTzStopMonth OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStopMonth-January(1),
- wtWebioAn2GraphStopMonth-February(2),
- wtWebioAn2GraphStopMonth-March(3),
- wtWebioAn2GraphStopMonth-April(4),
- wtWebioAn2GraphStopMonth-May(5),
- wtWebioAn2GraphStopMonth-June(6),
- wtWebioAn2GraphStopMonth-July(7),
- wtWebioAn2GraphStopMonth-August(8),
- wtWebioAn2GraphStopMonth-September(9),
- wtWebioAn2GraphStopMonth-October(10),
- wtWebioAn2GraphStopMonth-November(11),
- wtWebioAn2GraphStopMonth-December(12)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 12 }
- wtWebioAn2GraphStTzStopMode OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStopMode-first(1),
- wtWebioAn2GraphStopMode-second(2),
- wtWebioAn2GraphStopMode-third(3),
- wtWebioAn2GraphStopMode-fourth(4),
- wtWebioAn2GraphStopMode-last(5)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 13 }
- wtWebioAn2GraphStTzStopWday OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphStopWday-Sunday(1),
- wtWebioAn2GraphStopWday-Monday(2),
- wtWebioAn2GraphStopWday-Tuesday(3),
- wtWebioAn2GraphStopWday-Thursday(4),
- wtWebioAn2GraphStopWday-Wednesday(5),
- wtWebioAn2GraphStopWday-Friday(6),
- wtWebioAn2GraphStopWday-Saturday(7)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 14 }
- wtWebioAn2GraphStTzStopHrs OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
- umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 15 }
- wtWebioAn2GraphStTzStopMin OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC
- umgestellt wird."
- ::= { wtWebioAn2GraphTimeZone 16 }
- -- wtWebioAn2GraphTimeServer Group
- ----------------------------
- wtWebioAn2GraphTimeServer1 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse oder Name des 1. Time Servers in ASCII"
- ::= { wtWebioAn2GraphTimeServer 1 }
- wtWebioAn2GraphTimeServer2 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse oder Name des 2. Time Servers in ASCII"
- ::= { wtWebioAn2GraphTimeServer 2 }
- wtWebioAn2GraphTsEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Bedingung:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Apply Time Server"
- ::= { wtWebioAn2GraphTimeServer 3 }
- wtWebioAn2GraphTsSyncTime OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)."
- ::= { wtWebioAn2GraphTimeServer 4 }
- -- wtWebioAn2GraphDeviceClock Group
- ----------------------------
- wtWebioAn2GraphClockHrs OBJECT-TYPE
- SYNTAX INTEGER (0..23)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen."
- ::= { wtWebioAn2GraphDeviceClock 1 }
- wtWebioAn2GraphClockMin OBJECT-TYPE
- SYNTAX INTEGER (0..59)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen."
- ::= { wtWebioAn2GraphDeviceClock 2 }
- wtWebioAn2GraphClockDay OBJECT-TYPE
- SYNTAX INTEGER (1..31)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen."
- ::= { wtWebioAn2GraphDeviceClock 3 }
- wtWebioAn2GraphClockMonth OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphClockMonth-January(1),
- wtWebioAn2GraphClockMonth-February(2),
- wtWebioAn2GraphClockMonth-March(3),
- wtWebioAn2GraphClockMonth-April(4),
- wtWebioAn2GraphClockMonth-May(5),
- wtWebioAn2GraphClockMonth-June(6),
- wtWebioAn2GraphClockMonth-July(7),
- wtWebioAn2GraphClockMonth-August(8),
- wtWebioAn2GraphClockMonth-September(9),
- wtWebioAn2GraphClockMonth-October(10),
- wtWebioAn2GraphClockMonth-November(11),
- wtWebioAn2GraphClockMonth-December(12)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen."
- ::= { wtWebioAn2GraphDeviceClock 4 }
- wtWebioAn2GraphClockYear OBJECT-TYPE
- SYNTAX INTEGER (0..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen."
- ::= { wtWebioAn2GraphDeviceClock 5 }
- -- wtWebioAn2GraphNetwork Group
- ------------------------
- wtWebioAn2GraphIpAddress OBJECT-TYPE
- SYNTAX IpAddress
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse des Webio's"
- ::= { wtWebioAn2GraphNetwork 1 }
- wtWebioAn2GraphSubnetMask OBJECT-TYPE
- SYNTAX IpAddress
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Subnetmask des Webio's"
- ::= { wtWebioAn2GraphNetwork 2 }
- wtWebioAn2GraphGateway OBJECT-TYPE
- SYNTAX IpAddress
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Gateway des Webio's"
- ::= { wtWebioAn2GraphNetwork 3 }
- wtWebioAn2GraphDnsServer1 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse des 1. DNS Servers in ASCII"
- ::= { wtWebioAn2GraphNetwork 4 }
- wtWebioAn2GraphDnsServer2 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse des 2. DNS Servers in ASCII"
- ::= { wtWebioAn2GraphNetwork 5 }
- wtWebioAn2GraphAddConfig OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Zusatzkonfiguration (1=EIN):
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: BOOTP disable
- Bit 1: DHCP disable
- "
- ::= { wtWebioAn2GraphNetwork 6 }
- -- wtWebioAn2GraphHTTP Group
- --------------------------------
- wtWebioAn2GraphStartup OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Legt die Startseite fest, nur eine Auswahl zulässig:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 2: user.htm
- Bit 1: home.htm
- Bit 0: index.htm"
- ::= { wtWebioAn2GraphHTTP 1 }
- wtWebioAn2GraphGetHeaderEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wenn freigeschaltet, wird eine Erkennungssequenz und /oder ein HTTP-Kopf nach
- jeder GET-Anfrage der Antwort vorangestellt:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-6: ungenutzt
- Bit 1 : GET HTTP enable
- Bit 0 : GET Header enable"
- ::= { wtWebioAn2GraphHTTP 2 }
- wtWebioAn2GraphHttpPort OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "HTTP Port, an den die TCP-Anfragen gesendet werden können (Default: 80)."
- ::= { wtWebioAn2GraphHTTP 3 }
- -- wtWebioAn2GraphMail Group
- --------------------------------
- wtWebioAn2GraphMailAdName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Gerätename für die Mail-Administration."
- ::= { wtWebioAn2GraphMail 1 }
- wtWebioAn2GraphMailReply OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Reply-Adresse für den Mailserver."
- ::= { wtWebioAn2GraphMail 2 }
- wtWebioAn2GraphMailServer OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder Ip-Adresse des Mailservers."
- ::= { wtWebioAn2GraphMail 3 }
- wtWebioAn2GraphMailEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Erlaubt das versenden von Mails:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Mail enable"
- ::= { wtWebioAn2GraphMail 4 }
- wtWebioAn2GraphMailAuthentication OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE (4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Auswahl des Authenticationmodi:
- die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein.
- Bit 0 entspricht dem LSB.
- OCTET 1: ungenutzt
- OCTET 2: ungenutzt
- OCTET 3: ungenutzt
- OCTET 4: Bit 3-7: ungenutzt
- Bit 2 : POP3 vor SMTP
- Bit 1 : ESMTP, Authentifizierung
- Bit 0 : SMTP, keine Authentifizierung"
- ::= { wtWebioAn2GraphMail 5 }
- wtWebioAn2GraphMailAuthUser OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name des Postfaches / Postfachusers."
- ::= { wtWebioAn2GraphMail 6 }
- wtWebioAn2GraphMailAuthPassword OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Passwort zur Identifizierung des Users."
- ::= { wtWebioAn2GraphMail 7 }
- wtWebioAn2GraphMailPop3Server OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder Ip-Adresse des POP3 Servers."
- ::= { wtWebioAn2GraphMail 8 }
- -- wtWebioAn2GraphSNMP Group
- --------------------------------
- wtWebioAn2GraphSnmpCommunityStringRead OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Community string read only"
- ::= { wtWebioAn2GraphSNMP 1 }
- wtWebioAn2GraphSnmpCommunityStringReadWrite OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Community string read / write"
- ::= { wtWebioAn2GraphSNMP 2 }
- wtWebioAn2GraphSystemTrapManagerIP OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt."
- ::= { wtWebioAn2GraphSNMP 3 }
- wtWebioAn2GraphSystemTrapEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Triggerbedingungen:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: ColdStart
- Bit 1: WarmStart
- Bit 2-7: ungenutzt"
- ::= { wtWebioAn2GraphSNMP 4 }
- wtWebioAn2GraphSnmpEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bit 0 schaltet SNMP frei:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : SNMP enable"
- ::= { wtWebioAn2GraphSNMP 5 }
- wtWebioAn2GraphSnmpCommunityStringTrap OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Community string der Traps."
- ::= { wtWebioAn2GraphSNMP 6 }
- -- wtWebioAn2GraphUDP Group
- --------------------------------
- wtWebioAn2GraphUdpPort OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können"
- ::= { wtWebioAn2GraphUDP 1 }
- wtWebioAn2GraphUdpEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Schaltet UDP frei:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : UDP enable"
- ::= { wtWebioAn2GraphUDP 2 }
- -- wtWebioAn2GraphSyslog Group
- --------------------------------
- wtWebioAn2GraphSyslogServerIP OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt."
- ::= { wtWebioAn2GraphSyslog 1 }
- wtWebioAn2GraphSyslogServerPort OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Portnummer des Syslog-Servers, default ist 514."
- ::= { wtWebioAn2GraphSyslog 2 }
- wtWebioAn2GraphSyslogSystemMessagesEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Triggerbedingungen:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: ColdStart
- Bit 1: WarmStart
- Bit 2: Diag Messages
- Bit 3-7: ungenutzt"
- ::= { wtWebioAn2GraphSyslog 3 }
- wtWebioAn2GraphSyslogEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bit 0 schaltet Syslog frei:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Syslog enable"
- ::= { wtWebioAn2GraphSyslog 4 }
- -- wtWebioAn2GraphFTP Group
- --------------------------------
- wtWebioAn2GraphFTPServerIP OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt."
- ::= { wtWebioAn2GraphFTP 1 }
- wtWebioAn2GraphFTPServerControlPort OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Portnummer des Kontrollports des FTP-Servers, default ist 21."
- ::= { wtWebioAn2GraphFTP 2 }
- wtWebioAn2GraphFTPUserName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "FTP Loggin: Name des Anwenders."
- ::= { wtWebioAn2GraphFTP 3 }
- wtWebioAn2GraphFTPPassword OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "FTP Loggin: Passwort des Anwenders."
- ::= { wtWebioAn2GraphFTP 4 }
- wtWebioAn2GraphFTPAccount OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "FTP Loggin: Account-Name des Anwenderkontos."
- ::= { wtWebioAn2GraphFTP 5 }
- wtWebioAn2GraphFTPOption OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bit 0 schaltet den FTP Server in den Passiv-Modus,
- der Client kontrolliert die Datenverbindung allein:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : PASV enable"
- ::= { wtWebioAn2GraphFTP 6 }
- wtWebioAn2GraphFTPEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bit 0 schaltet FTP frei:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : FTP enable"
- ::= { wtWebioAn2GraphFTP 7 }
- -- wtWebioAn2GraphDatalogger Group
- --------------------------------
- wtWebioAn2GraphLoggerTimebase OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphDatalogger-1Min(1),
- wtWebioAn2GraphDatalogger-5Min(2),
- wtWebioAn2GraphDatalogger-15Min(3),
- wtWebioAn2GraphDatalogger-60Min(4)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Zeitbasis des Dataloggers"
- ::= { wtWebioAn2GraphDatalogger 1 }
- wtWebioAn2GraphLoggerSensorSel OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Triggerbedingungen:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: Sensor 1
- Bit 1: Sensor 2
- Bit 2: Sensor 3
- Bit 3: Sensor 4
- Bit 4: Sensor 5
- Bit 5: Sensor 6
- Bit 6: Sensor 7
- Bit 7: Sensor 8"
- ::= { wtWebioAn2GraphDatalogger 2 }
- wtWebioAn2GraphDisplaySensorSel OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Die hier ausgewählten Sensoren werden grafisch angezeigt:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: Sensor 1
- Bit 1: Sensor 2
- Bit 2: Sensor 3
- Bit 3: Sensor 4
- Bit 4: Sensor 5
- Bit 5: Sensor 6
- Bit 6: Sensor 7
- Bit 7: Sensor 8"
- ::= { wtWebioAn2GraphDatalogger 3 }
- -- Graph Sensor Color Table
- wtWebioAn2GraphSensorColorTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphSensorColorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Sensorfarben in der grafischen Darstellung."
- ::= { wtWebioAn2GraphDatalogger 4 }
- wtWebioAn2GraphSensorColorEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphSensorColorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Nummern der Sensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphSensorColorTable 1 }
- wtWebioAn2GraphSensorColorEntry ::= SEQUENCE {
- wtWebioAn2GraphSensorColor OCTET STRING
- }
- wtWebioAn2GraphSensorColor OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(3))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Farbe des Sensors in der grafischen Darstellung."
- ::= { wtWebioAn2GraphSensorColorEntry 1 }
- wtWebioAn2GraphAutoScaleEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bit 0 schaltet Vertical Auto Scale frei:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 1-7: ungenutzt
- Bit 0 : Auto Scale enable"
- ::= { wtWebioAn2GraphDatalogger 5 }
- wtWebioAn2GraphVerticalUpperLimit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert die maximal sichtbare Temperatur für die grafische Darstellung.
- Temperatur in Grad mit maximal 2 Nachkommastellen."
- ::= { wtWebioAn2GraphDatalogger 6 }
- wtWebioAn2GraphVerticalLowerLimit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert die Minal sichtbare Temperatur für die grafische Darstellung.
- Temperatur in Grad mit maximal 2 Nachkommastellen."
- ::= { wtWebioAn2GraphDatalogger 7 }
- wtWebioAn2GraphHorizontalZoom OBJECT-TYPE
- SYNTAX INTEGER {
- wtWebioAn2GraphZoom-25Min(1),
- wtWebioAn2GraphZoom-75Min(2),
- wtWebioAn2GraphZoom-5Std(3),
- wtWebioAn2GraphZoom-30Std(4),
- wtWebioAn2GraphZoom-5Tage(5),
- wtWebioAn2GraphZoom-25Tage(6)
- }
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert den default Zoom."
- ::= { wtWebioAn2GraphDatalogger 8 }
- -- wtWebioAn2GraphAlarm Group
- ----------------------------
- wtWebioAn2GraphAlarmCount OBJECT-TYPE
- SYNTAX INTEGER (1..2)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Anzahl der unabhängigen Alarme."
- ::= { wtWebioAn2GraphAlarm 1 }
- -- Alarm Interface Table
- wtWebioAn2GraphAlarmIfTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphAlarmIfEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Alarmindizes."
- ::= { wtWebioAn2GraphAlarm 2 }
- wtWebioAn2GraphAlarmIfEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphAlarmIfEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Nummern der Alarme."
- INDEX { wtWebioAn2GraphAlarmNo }
- ::= { wtWebioAn2GraphAlarmIfTable 1 }
- wtWebioAn2GraphAlarmIfEntry ::= SEQUENCE {
- wtWebioAn2GraphAlarmNo INTEGER
- }
- wtWebioAn2GraphAlarmNo OBJECT-TYPE
- SYNTAX INTEGER (1..2)
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Nummer des Alarms."
- ::= { wtWebioAn2GraphAlarmIfEntry 1 }
- -- Alarm Table
- wtWebioAn2GraphAlarmTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphAlarmEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Einstellungen abhängig von der Alarmnummer."
- ::= { wtWebioAn2GraphAlarm 3 }
- wtWebioAn2GraphAlarmEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphAlarmEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Alarm-Parameter der einzelnen Alarme."
- INDEX { wtWebioAn2GraphAlarmNo }
- ::= { wtWebioAn2GraphAlarmTable 1 }
- wtWebioAn2GraphAlarmEntry ::= SEQUENCE {
- wtWebioAn2GraphAlarmTrigger OCTET STRING,
- wtWebioAn2GraphAlarmMin OCTET STRING,
- wtWebioAn2GraphAlarmMax OCTET STRING,
- wtWebioAn2GraphAlarmHysteresis OCTET STRING,
- wtWebioAn2GraphAlarmDelay OCTET STRING,
- wtWebioAn2GraphAlarmInterval OCTET STRING,
- wtWebioAn2GraphAlarmEnable OCTET STRING,
- wtWebioAn2GraphAlarmEMailAddr OCTET STRING,
- wtWebioAn2GraphAlarmMailSubject OCTET STRING,
- wtWebioAn2GraphAlarmMailText OCTET STRING,
- wtWebioAn2GraphAlarmManagerIP OCTET STRING,
- wtWebioAn2GraphAlarmTrapText OCTET STRING,
- wtWebioAn2GraphAlarmMailOptions OCTET STRING,
- wtWebioAn2GraphAlarmTcpIpAddr OCTET STRING,
- wtWebioAn2GraphAlarmTcpPort INTEGER,
- wtWebioAn2GraphAlarmTcpText OCTET STRING,
- wtWebioAn2GraphAlarmClearMailSubject OCTET STRING,
- wtWebioAn2GraphAlarmClearMailText OCTET STRING,
- wtWebioAn2GraphAlarmClearTrapText OCTET STRING,
- wtWebioAn2GraphAlarmClearTcpText OCTET STRING,
- wtWebioAn2GraphAlarmSyslogIpAddr OCTET STRING,
- wtWebioAn2GraphAlarmSyslogPort INTEGER,
- wtWebioAn2GraphAlarmSyslogText OCTET STRING,
- wtWebioAn2GraphAlarmSyslogClearText OCTET STRING,
- wtWebioAn2GraphAlarmFtpDataPort OCTET STRING,
- wtWebioAn2GraphAlarmFtpFileName OCTET STRING,
- wtWebioAn2GraphAlarmFtpText OCTET STRING,
- wtWebioAn2GraphAlarmFtpClearText OCTET STRING,
- wtWebioAn2GraphAlarmFtpOption OCTET STRING,
- wtWebioAn2GraphAlarmTimerCron OCTET STRING
- }
- wtWebioAn2GraphAlarmTrigger OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Triggerbedingungen:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3:
- Bit 0: Timer
- Bit 1: ColdStart
- Bit 2: WarmStart
- Bit 3: Sensor lost
- Bit 4-7 ungenutzt
- Octet 4:
- Bit 0: Sensor 1
- Bit 1: Sensor 2
- Bit 2: Sensor 3
- Bit 3: Sensor 4
- Bit 4: Sensor 5
- Bit 5: Sensor 6
- Bit 6: Sensor 7
- Bit 7: Sensor 8"
- ::= { wtWebioAn2GraphAlarmEntry 1 }
- wtWebioAn2GraphAlarmMin OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen."
- ::= { wtWebioAn2GraphAlarmEntry 2 }
- wtWebioAn2GraphAlarmMax OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen."
- ::= { wtWebioAn2GraphAlarmEntry 3 }
- wtWebioAn2GraphAlarmHysteresis OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst.
- wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen."
- ::= { wtWebioAn2GraphAlarmEntry 4 }
- wtWebioAn2GraphAlarmDelay OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit
- die Alarmbedingungen erfüllt sind (Zeit in Minuten)."
- ::= { wtWebioAn2GraphAlarmEntry 5 }
- wtWebioAn2GraphAlarmInterval OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Sendeintervall von Alarmmeldungen."
- ::= { wtWebioAn2GraphAlarmEntry 6 }
- wtWebioAn2GraphAlarmEnable OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Alarmfreischaltung:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: Mail Enable
- Bit 1: SNMP Trap enable
- Bit 2: TCP Client enable"
- ::= { wtWebioAn2GraphAlarmEntry 7 }
- wtWebioAn2GraphAlarmEMailAddr OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "E-Mail Adresse, an die die Alarmmail gesendet werden soll."
- ::= { wtWebioAn2GraphAlarmEntry 8 }
- wtWebioAn2GraphAlarmMailSubject OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Betreffzeile der Alarmmail."
- ::= { wtWebioAn2GraphAlarmEntry 9 }
- wtWebioAn2GraphAlarmMailText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Text der Alarmmail: <Tn> liefert die aktuelle Temperatur; n = 1..2.
- <Z> liefert die aktuelle Zeit."
- ::= { wtWebioAn2GraphAlarmEntry 10 }
- wtWebioAn2GraphAlarmManagerIP OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt."
- ::= { wtWebioAn2GraphAlarmEntry 11 }
- wtWebioAn2GraphAlarmTrapText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird im Trapbody gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 12 }
- wtWebioAn2GraphAlarmMailOptions OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Optionen:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : Attach Thermo.csv Enable
- Bit 1 : CSV-Data_since_last_report
- Bit 2-7: ungenutzt"
- ::= { wtWebioAn2GraphAlarmEntry 13 }
- wtWebioAn2GraphAlarmTcpIpAddr OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll."
- ::= { wtWebioAn2GraphAlarmEntry 14 }
- wtWebioAn2GraphAlarmTcpPort OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll."
- ::= { wtWebioAn2GraphAlarmEntry 15 }
- wtWebioAn2GraphAlarmTcpText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird im TCP Trapbody gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 16 }
- wtWebioAn2GraphAlarmClearMailSubject OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Betreffzeile der Alarm Clear Mail."
- ::= { wtWebioAn2GraphAlarmEntry 17 }
- wtWebioAn2GraphAlarmClearMailText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Text der Alarm Clear Mail: <Tn> liefert die aktuelle Temperatur; n = 1..2.
- <Z> liefert die aktuelle Zeit."
- ::= { wtWebioAn2GraphAlarmEntry 18 }
- wtWebioAn2GraphAlarmClearTrapText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird im Trapbody gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 19 }
- wtWebioAn2GraphAlarmClearTcpText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird im TCP Trapbody gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 20 }
- wtWebioAn2GraphAlarmSyslogIpAddr OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "IP-Adresse des Gerätes, dass eine Syslog-Nachricht empfangen soll."
- ::= { wtWebioAn2GraphAlarmEntry 21 }
- wtWebioAn2GraphAlarmSyslogPort OBJECT-TYPE
- SYNTAX INTEGER (1..65535)
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Portnummer des Gerätes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514."
- ::= { wtWebioAn2GraphAlarmEntry 22 }
- wtWebioAn2GraphAlarmSyslogText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164.
- Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 23 }
- wtWebioAn2GraphAlarmSyslogClearText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164.
- Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet."
- ::= { wtWebioAn2GraphAlarmEntry 24 }
- wtWebioAn2GraphAlarmFtpDataPort OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Lokaler Datenport: 1..65535 oder AUTO: der nächste ungenutzte Port wird automatisch zugewiesen."
- ::= { wtWebioAn2GraphAlarmEntry 25 }
- wtWebioAn2GraphAlarmFtpFileName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Der File Name kann auch Pfadinformationen enthalten."
- ::= { wtWebioAn2GraphAlarmEntry 26 }
- wtWebioAn2GraphAlarmFtpText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird in die angegebene Datei geschrieben."
- ::= { wtWebioAn2GraphAlarmEntry 27 }
- wtWebioAn2GraphAlarmFtpClearText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Text wird in die angegebene Datei geschrieben."
- ::= { wtWebioAn2GraphAlarmEntry 28 }
- wtWebioAn2GraphAlarmFtpOptions OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Optionen, nur eine Option darf eingeschaltet sein:
- STORE = Datei ersetzen
- APPEND = Nachrichten ans Dateiende anhängen
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : STORE
- Bit 1 : APPEND
- Bit 2-7: ungenutzt"
- ::= { wtWebioAn2GraphAlarmEntry 29 }
- wtWebioAn2GraphAlarmTimerCron OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Dieser Eintrag enthält 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten
- Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit übereinstimmen, um
- das Senden einer Nachricht auszulösen, Wochentag und Monatstag werden getrennt ausgewertet.
- Feld möglicher Zahlenbereich
- 1: Minuten 0-59
- 2. Stunden 0-23, 0 ist Mitternacht
- 3: Monatstag 1-31
- 4: Monat 1-12
- 5: Wochentag 0-6, 0 ist Sonntag
- Für jedes Feld kann nun angegeben werden:
- - eine ganze Zahl aus dem angegebenen Zahlenbereich
- - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs
- - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10)
- - ein Stern * (deckt den gesamten erlaubten Bereich ab)
- - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)."
- ::= { wtWebioAn2GraphAlarmEntry 30 }
- -- wtWebioAn2GraphGraphicsBase Group
- ----------------------------
- wtWebioAn2GraphGraphicsBaseEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Legt die Anzeigeelemente der Grafik fest:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : Auto scroll enable
- Bit 1 : Show table
- Bit 2 : Show graph
- Bit 3 : Show control buttons
- Bit 4 : Show config menu
- Bit 5-7: ungenutzt"
- ::= { wtWebioAn2GraphGraphicsBase 1 }
- wtWebioAn2GraphGraphicsBaseWidth OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert die Breite der Grafik in Pixeln."
- ::= { wtWebioAn2GraphGraphicsBase 2 }
- wtWebioAn2GraphGraphicsBaseHeight OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert die Höhe der Grafik in Pixeln."
- ::= { wtWebioAn2GraphGraphicsBase 3 }
- wtWebioAn2GraphGraphicsBaseFrameColor OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(3))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Farbe des Rahmens in der grafischen Darstellung."
- ::= { wtWebioAn2GraphGraphicsBase 4 }
- wtWebioAn2GraphGraphicsBaseBackgroundColor OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(3))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Farbe der Hintergrundfarbe in der grafischen Darstellung."
- ::= { wtWebioAn2GraphGraphicsBase 5 }
- wtWebioAn2GraphGraphicsBasePollingrate OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Definiert die Abfragerate in Sekunden,
- mit der die Grafik aktualisiert wird."
- ::= { wtWebioAn2GraphGraphicsBase 6 }
- -- wtWebioAn2GraphGraphicsSelect Group
- ----------------------------
- wtWebioAn2GraphGraphicsSelectDisplaySensorSel OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Die hier ausgewählten Sensoren werden grafisch angezeigt:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: Sensor 1
- Bit 1: Sensor 2
- Bit 2: Sensor 3
- Bit 3: Sensor 4
- Bit 4: Sensor 5
- Bit 5: Sensor 6
- Bit 6: Sensor 7
- Bit 7: Sensor 8"
- ::= { wtWebioAn2GraphGraphicsSelect 1 }
- wtWebioAn2GraphGraphicsSelectDisplayShowExtrem OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Die Anzeige von Minima und Maxima der hier ausgewählten Sensoren
- wird freigeschaltet:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0: Sensor 1
- Bit 1: Sensor 2
- Bit 2: Sensor 3
- Bit 3: Sensor 4
- Bit 4: Sensor 5
- Bit 5: Sensor 6
- Bit 6: Sensor 7
- Bit 7: Sensor 8"
- ::= { wtWebioAn2GraphGraphicsSelect 2 }
- -- Graph Sensor Color Table
- wtWebioAn8GraphSensorColorTable OBJECT-TYPE
- SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Sensorfarben in der grafischen Darstellung."
- ::= { wtWebioAn2GraphGraphicsSelect 3 }
- wtWebioAn8GraphSensorColorEntry OBJECT-TYPE
- SYNTAX WtWebioAn8GraphSensorColorEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Nummern der Sensoren."
- INDEX { wtWebioAn8GraphSensorNo }
- ::= { wtWebioAn8GraphSensorColorTable 1 }
- WtWebioAn8GraphSensorColorEntry ::= SEQUENCE {
- wtWebioAn2GraphGraphicsSensorColor OCTET STRING,
- wtWebioAn2GraphGraphicsSelectScale OCTET STRING
- }
- wtWebioAn2GraphGraphicsSensorColor OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(3))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Farbe des Sensors in der grafischen Darstellung."
- ::= { wtWebioAn8GraphSensorColorEntry 1 }
- wtWebioAn2GraphGraphicsSelectScale OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Zuweisung einer Skalierung zu einem Sensor:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : Use Scale 1
- Bit 1 : Use Scale 2
- Bit 2 : Use Scale 3
- Bit 3 : Use Scale 4
- Bit 4-7: ungenutzt"
- ::= { wtWebioAn8GraphSensorColorEntry 2 }
- -- wtWebioAn2GraphGraphicsScale Group
- ----------------------------
- wtWebioAn2GraphGraphicsScaleAutoScaleEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wählt den Auto Scale Modus für die jeweilige Skalierung aus:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : Scale 1 Auto scale enable
- Bit 1 : Scale 2 Auto scale enable
- Bit 2 : Scale 3 Auto scale enable
- Bit 3 : Scale 4 Auto scale enable
- Bit 4-7: ungenutzt"
- ::= { wtWebioAn2GraphGraphicsScale 1 }
- wtWebioAn2GraphGraphicsScaleAutoFitEnable OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Wählt den Auto Fit Modus für die jeweilige Skalierung aus:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : Scale 1 Auto fit enable
- Bit 1 : Scale 2 Auto fit enable
- Bit 2 : Scale 3 Auto fit enable
- Bit 3 : Scale 4 Auto fit enable
- Bit 4-7: ungenutzt"
- ::= { wtWebioAn2GraphGraphicsScale 2 }
- wtWebioAn2GraphGraphicsScale1Min OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 1: Minimum."
- ::= { wtWebioAn2GraphGraphicsScale 3 }
- wtWebioAn2GraphGraphicsScale2Min OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 2: Minimum."
- ::= { wtWebioAn2GraphGraphicsScale 4 }
- wtWebioAn2GraphGraphicsScale3Min OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 3: Minimum."
- ::= { wtWebioAn2GraphGraphicsScale 5 }
- wtWebioAn2GraphGraphicsScale4Min OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 4: Minimum."
- ::= { wtWebioAn2GraphGraphicsScale 6 }
- wtWebioAn2GraphGraphicsScale1Max OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 1: Maximum."
- ::= { wtWebioAn2GraphGraphicsScale 7 }
- wtWebioAn2GraphGraphicsScale2Max OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 2: Maximum."
- ::= { wtWebioAn2GraphGraphicsScale 8 }
- wtWebioAn2GraphGraphicsScale3Max OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 3: Maximum."
- ::= { wtWebioAn2GraphGraphicsScale 9 }
- wtWebioAn2GraphGraphicsScale4Max OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 4: Maximum."
- ::= { wtWebioAn2GraphGraphicsScale 10 }
- wtWebioAn2GraphGraphicsScale1Unit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 1: Einheit."
- ::= { wtWebioAn2GraphGraphicsScale 11 }
- wtWebioAn2GraphGraphicsScale2Unit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 2: Einheit."
- ::= { wtWebioAn2GraphGraphicsScale 12 }
- wtWebioAn2GraphGraphicsScale3Unit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 3: Einheit."
- ::= { wtWebioAn2GraphGraphicsScale 13 }
- wtWebioAn2GraphGraphicsScale4Unit OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Skalierung 4: Einheit."
- ::= { wtWebioAn2GraphGraphicsScale 14 }
- -- wtWebioAn2GraphPorts Group
- ----------------------------
- -- Table
- wtWebioAn2GraphPortTable OBJECT-TYPE
- SYNTAX SEQUENCE OF wtWebioAn2GraphPortEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Liste der Einstellungen abhängig von der Sensornummer."
- ::= { wtWebioAn2GraphPorts 1 }
- wtWebioAn2GraphPortEntry OBJECT-TYPE
- SYNTAX wtWebioAn2GraphPortEntry
- ACCESS not-accessible
- STATUS mandatory
- DESCRIPTION
- "Sensor-Parameter der einzelnen Sensoren."
- INDEX { wtWebioAn2GraphSensorNo }
- ::= { wtWebioAn2GraphPortTable 1 }
- wtWebioAn2GraphPortEntry ::= SEQUENCE {
- wtWebioAn2GraphPortName OCTET STRING,
- wtWebioAn2GraphPortText OCTET STRING,
- wtWebioAn2GraphPortOffset1 OCTET STRING,
- wtWebioAn2GraphPortTemperature1 OCTET STRING,
- wtWebioAn2GraphPortOffset2 OCTET STRING,
- wtWebioAn2GraphPortTemperature2 OCTET STRING,
- wtWebioAn2GraphPortComment OCTET STRING,
- wtWebioAn2GraphPortSensorSelect OCTET STRING
- }
- wtWebioAn2GraphPortName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Name des Sensors."
- ::= { wtWebioAn2GraphPortEntry 1 }
- wtWebioAn2GraphPortText OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Beschreibung des Sensors."
- ::= { wtWebioAn2GraphPortEntry 2 }
- wtWebioAn2GraphPortOffset1 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1."
- ::= { wtWebioAn2GraphPortEntry 3 }
- wtWebioAn2GraphPortTemperature1 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen."
- ::= { wtWebioAn2GraphPortEntry 4 }
- wtWebioAn2GraphPortOffset2 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2."
- ::= { wtWebioAn2GraphPortEntry 5 }
- wtWebioAn2GraphPortTemperature2 OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen."
- ::= { wtWebioAn2GraphPortEntry 6 }
- wtWebioAn2GraphPortComment OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator."
- ::= { wtWebioAn2GraphPortEntry 7 }
- wtWebioAn2GraphPortSensorSelect OBJECT-TYPE
- SYNTAX OCTET STRING (SIZE(4))
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Binär kodierte Optionen für Sensor:
- Octet 1: ungenutzt
- Octet 2: ungenutzt
- Octet 3: ungenutzt
- Octet 4:
- Bit 0 : PT100
- Bit 1 : PT1000 (default)
- Bit 2-7: ungenutzt"
- ::= { wtWebioAn2GraphPortEntry 8 }
- -- wtWebioAn2GraphManufact Group
- ----------------------------
- wtWebioAn2GraphMfName OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Hersteller Firmenname"
- ::= { wtWebioAn2GraphManufact 1 }
- wtWebioAn2GraphMfAddr OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Adresse des Herstellers."
- ::= { wtWebioAn2GraphManufact 2 }
- wtWebioAn2GraphMfHotline OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Hotline des Herstellers."
- ::= { wtWebioAn2GraphManufact 3 }
- wtWebioAn2GraphMfInternet OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Internet-Adresse des Herstellers."
- ::= { wtWebioAn2GraphManufact 4 }
- wtWebioAn2GraphMfDeviceTyp OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Gerätebezeichnung (Typ) des Herstellers."
- ::= { wtWebioAn2GraphManufact 5 }
- wtWebioAn2GraphMfOrderNo OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Bestellnummer des Gerätes des Herstellers."
- ::= { wtWebioAn2GraphManufact 6 }
- -- wtWebioAn2GraphDiag Group
- ----------------------------
- wtWebioAn2GraphDiagErrorCount OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Anzahl der Einträge im Fehlerspeicher."
- ::= { wtWebioAn2GraphDiag 1 }
- wtWebioAn2GraphDiagBinaryError OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Bitweise kodierte Fehlerursachen."
- ::= { wtWebioAn2GraphDiag 2 }
- wtWebioAn2GraphDiagErrorIndex OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS read-write
- STATUS mandatory
- DESCRIPTION
- "Der Wert dieser Variable wird als Index für die Ausgabe
- eines Fehlertextes (wtWebioAn2GraphDiagErrorMessage) verwendet.
- Die Fehler im Speicher sind von 1 bis wtWebioAn2GraphDiagErrorCount durchnummeriert.
- Nach dem Schreiben einens gültigen Wertes in diese Variable kann der dazugehörige Text
- in wtWebioAn2GraphDiagErrorMessage ausgelesen werden."
- ::= { wtWebioAn2GraphDiag 3 }
- wtWebioAn2GraphDiagErrorMessage OBJECT-TYPE
- SYNTAX OCTET STRING
- ACCESS read-only
- STATUS mandatory
- DESCRIPTION
- "Abhängig vom Wert wtWebioAn2GraphDiagErrorIndex wird ein Fehlertext angezeigt."
- ::= { wtWebioAn2GraphDiag 4 }
- wtWebioAn2GraphDiagErrorClear OBJECT-TYPE
- SYNTAX INTEGER
- ACCESS write-only
- STATUS mandatory
- DESCRIPTION
- "Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelöscht."
- ::= { wtWebioAn2GraphDiag 5 }
- -- TRAP DEFINITIONS
- -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
- wtWebioAn2GraphAlert1 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 1"
- --#SUMMARY "Alarm 1: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 21
- wtWebioAn2GraphAlert2 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 2"
- --#SUMMARY "Alarm 2: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 22
- wtWebioAn2GraphAlert3 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 3"
- --#SUMMARY "Alarm 3: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 23
- wtWebioAn2GraphAlert4 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 4"
- --#SUMMARY "Alarm 4: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 24
- wtWebioAn2GraphAlert5 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 5"
- --#SUMMARY "Alarm 5: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 25
- wtWebioAn2GraphAlert6 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 6"
- --#SUMMARY "Alarm 6: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 26
- wtWebioAn2GraphAlert7 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 7"
- --#SUMMARY "Alarm 7: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 27
- wtWebioAn2GraphAlert8 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Alarm 8"
- --#SUMMARY "Alarm 8: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 28
- wtWebioAn2GraphAlert9 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 1"
- --#SUMMARY "Release Alarm 1: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 81
- wtWebioAn2GraphAlert10 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 2"
- --#SUMMARY "Release Alarm 2: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 82
- wtWebioAn2GraphAlert11 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 3"
- --#SUMMARY "Release Alarm 3: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 83
- wtWebioAn2GraphAlert12 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 4"
- --#SUMMARY "Release Alarm 4: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 84
- wtWebioAn2GraphAlert13 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 5"
- --#SUMMARY "Release Alarm 5: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 85
- wtWebioAn2GraphAlert14 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 6"
- --#SUMMARY "Release Alarm 6: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 86
- wtWebioAn2GraphAlert15 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 7"
- --#SUMMARY "Release Alarm 7: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 87
- wtWebioAn2GraphAlert16 TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES { wtWebioAn2GraphAlarmClearTrapText }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Release Alarm 8"
- --#SUMMARY "Release Alarm 8: %s"
- --#ARGUMENTS {0}
- --#SEVERITY INFORMATIONAL
- --#TIMEINDEX 99
- --#STATE OPERATIONAL
- ::= 88
- wtWebioAn2GraphAlertDiag TRAP-TYPE
- ENTERPRISE wtWebioAn2Graph
- VARIABLES {
- wtWebioAn2GraphDiagErrorIndex,
- wtWebioAn2GraphDiagErrorMessage
- }
- DESCRIPTION
- "Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelöst wurde,
- das SNMP-Trap-Enable gesetzt ist und
- SNMP in Enable freigegeben ist."
- -- NMS trap annotation
- --#TYPE "Web-Thermograph Diagnose Error"
- --#SUMMARY "Diagnose error index: %d, Message: %s."
- --#ARGUMENTS {0,1}
- --#SEVERITY MAJOR
- --#TIMEINDEX 99
- --#STATE DEGRADED
- ::= 110
- END