WebGraph-2xThermometer-MIB DEFINITIONS ::= BEGIN ---------------------------------------------------------------- -- Revison: 1.30 ---------------------------------------------------------------- -- 22.06.2010 Messwertausgabe mit Punkt als Trennzeichen -- ---------------------------------------------------------------- -- Revison: 1.28 ---------------------------------------------------------------- -- 19.01.2007 Webio -- New Graphics javascript base parameter ---------------------------------------------------------------- -- Revison: 1.27 ---------------------------------------------------------------- -- 09.11.2006 Webio -- DHCP enable ---------------------------------------------------------------- -- Revison: 1.25 ---------------------------------------------------------------- -- 28.06.2006 New: Community String Trap -- ---------------------------------------------------------------- -- Revison: 1.24 ---------------------------------------------------------------- -- 23.12.2005 #57607, WebGraph 2x Thermometer -- IMPORTS OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, PhysAddress FROM RFC1213-MIB enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI; -- IpAddress ::= -- [APPLICATION 0] -- IMPLICIT OCTET STRING (SIZE (4)) -- Counter ::= -- [APPLICATION 1] -- IMPLICIT INTEGER (0..4294967295) -- Gauge ::= -- [APPLICATION 2] -- IMPLICIT INTEGER (0..4294967295) -- TimeTicks ::= -- [APPLICATION 3] -- IMPLICIT INTEGER (0..4294967295) -- DisplayString ::= OCTET STRING -- PhysAddress ::= OCTET STRING -- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 } -- privat OBJECT IDENTIFIER ::= { internet 4 } -- enterprises OBJECT IDENTIFIER ::= { privat 1 } -- Wiesemann & Theis Com-Server MIB wut OBJECT IDENTIFIER ::= { enterprises 5040 } wtComServer OBJECT IDENTIFIER ::= { wut 1 } wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 } -- wtWebio Tree wtWebioAn2Graph OBJECT IDENTIFIER ::= { wtWebio 7 } -- wtWebioAn2Graph Tree wtWebioAn2GraphTemp OBJECT IDENTIFIER ::= { wtWebioAn2Graph 1 } wtWebioAn2GraphSessCntrl OBJECT IDENTIFIER ::= { wtWebioAn2Graph 2 } wtWebioAn2GraphConfig OBJECT IDENTIFIER ::= { wtWebioAn2Graph 3 } wtWebioAn2GraphDiag OBJECT IDENTIFIER ::= { wtWebioAn2Graph 4 } -- wtWebioAn2GraphConfig Tree wtWebioAn2GraphDevice OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 1 } wtWebioAn2GraphPorts OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 2 } wtWebioAn2GraphManufact OBJECT IDENTIFIER ::= { wtWebioAn2GraphConfig 3 } -- wtWebioAn2GraphDevice Tree wtWebioAn2GraphText OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 1 } wtWebioAn2GraphTimeDate OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 2 } wtWebioAn2GraphBasic OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 3 } wtWebioAn2GraphDatalogger OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 4 } wtWebioAn2GraphAlarm OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 5 } wtWebioAn2GraphGraphics OBJECT IDENTIFIER ::= { wtWebioAn2GraphDevice 6 } -- wtWebioAn2GraphTimeDate Tree wtWebioAn2GraphTimeZone OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 1 } wtWebioAn2GraphTimeServer OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 2 } wtWebioAn2GraphDeviceClock OBJECT IDENTIFIER ::= { wtWebioAn2GraphTimeDate 3 } -- wtWebioAn2GraphBasic Tree wtWebioAn2GraphNetwork OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 1 } wtWebioAn2GraphHTTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 2 } wtWebioAn2GraphMail OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 3 } wtWebioAn2GraphSNMP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 4 } wtWebioAn2GraphUDP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 5 } wtWebioAn2GraphSyslog OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 6 } wtWebioAn2GraphFTP OBJECT IDENTIFIER ::= { wtWebioAn2GraphBasic 7 } -- wtWebioAn2GraphGraphics Tree wtWebioAn2GraphGraphicsBase OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 1 } wtWebioAn2GraphGraphicsSelect OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 2 } wtWebioAn2GraphGraphicsScale OBJECT IDENTIFIER ::= { wtWebioAn2GraphGraphics 3 } -- wtWebioAn2GraphTemp Group ------------------------ wtWebioAn2GraphSensors OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der Temperatursensoren" ::= { wtWebioAn2GraphTemp 1 } -- Interface Table wtWebioAn2GraphSensorTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Sensoren." ::= { wtWebioAn2GraphTemp 2 } wtWebioAn2GraphSensorEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphSensorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Temperatursensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphSensorTable 1 } wtWebioAn2GraphSensorEntry ::= SEQUENCE { wtWebioAn2GraphSensorNo INTEGER } wtWebioAn2GraphSensorNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Nummer des Temperatursensors." ::= { wtWebioAn2GraphSensorEntry 1 } -- wtWebioAn2GraphTempValue Table wtWebioAn2GraphTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." ::= { wtWebioAn2GraphTemp 3 } wtWebioAn2GraphTempValueEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperaturen der Sensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphTempValueTable 1 } wtWebioAn2GraphTempValueEntry ::= SEQUENCE{ wtWebioAn2GraphTempValue OCTET STRING } wtWebioAn2GraphTempValue OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperaturwert des Sensors, ASCII, 5 Zeichen lang." ::= { wtWebioAn2GraphTempValueEntry 1 } -- wtWebioAn2GraphBinaryTempValue Table wtWebioAn2GraphBinaryTempValueTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste binärer Temperaturwerte korrespondiernd zu den Kanalnummern." ::= { wtWebioAn2GraphTemp 4 } wtWebioAn2GraphBinaryTempValueEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphBinaryTempValueEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Binäre Temperaturen der Sensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphBinaryTempValueTable 1 } wtWebioAn2GraphBinaryTempValueEntry ::= SEQUENCE{ wtWebioAn2GraphBinaryTempValue INTEGER } wtWebioAn2GraphBinaryTempValue OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Binärer Temperaturwert des Sensors in 1/10 Grad Celcius, vorzeichenbehaftete Zahl, der Wert 0x4FFF6 zeigt einen ungültigen Messwert an." ::= { wtWebioAn2GraphBinaryTempValueEntry 1 } -- wtWebioAn2GraphTempValuePkt Table wtWebioAn2GraphTempValuePktTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn2GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste Temperaturwerte korrespondiernd zu den Kanalnummern." ::= { wtWebioAn2GraphTemp 8 } wtWebioAn2GraphTempValuePktEntry OBJECT-TYPE SYNTAX WtWebioAn2GraphTempValuePktEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Temperaturen der Sensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphTempValuePktTable 1 } WtWebioAn2GraphTempValuePktEntry ::= SEQUENCE{ wtWebioAn2GraphTempValuePkt OCTET STRING } wtWebioAn2GraphTempValuePkt OBJECT-TYPE SYNTAX OCTET STRING (SIZE (5)) ACCESS read-only STATUS mandatory DESCRIPTION "Temperaturwert des Sensors, ASCII, 5 Zeichen lang, dezimal Punkt." ::= { wtWebioAn2GraphTempValuePktEntry 1 } -- wtWebioAn2GraphSessCntrl Group -------------------------------- wtWebioAn2GraphSessCntrlPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Durch Eintrag diese Passworts wird eine Session eröffnet, die durch Schreiben einer 1 in wtWebioAn2GraphSessCntrlLogout beendet wird. Gelesen liefert diese Variable einen String der Länge Null." ::= { wtWebioAn2GraphSessCntrl 1 } wtWebioAn2GraphSessCntrlConfigMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphSessCntrl-NoSession(0), wtWebioAn2GraphSessCntrl-Session(1) } ACCESS read-only STATUS mandatory DESCRIPTION "Wenn sich das Gerät im SNMP-Konfigurationsmodus befindet, wird der Wert 1 zurückgeliefert, ansonsten 0. Ist der ausgelesene Wert 0 obwohl das Passwort geschrieben wurde, befindet sich das Gerät bereits im Configmodus und die Variablen können nur gelesen werden." ::= { wtWebioAn2GraphSessCntrl 2 } wtWebioAn2GraphSessCntrlLogout OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Wenn sich das Gerät im Konfigurationsmodus befindet und die Session wurde von diesem SNMP Manager eröffnet, kann durch Schreiben einer 1 in diese Variable die Session beendet werden und alle Parameter werden gespeichert. Durch Schreiben einer 2 werden alle Eingaben wieder verworfen. Gelesen liefert diese Variable den Wert 0." ::= { wtWebioAn2GraphSessCntrl 3 } wtWebioAn2GraphSessCntrlAdminPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieses Passwort schützt den Zugang der Variablen mit Administratorrechten. Es kann nur vom Administrator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort. Gelesen liefert diese Variable einen Null-Pointer." ::= { wtWebioAn2GraphSessCntrl 4 } wtWebioAn2GraphSessCntrlConfigPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieses Passwort schützt den Zugang der Variablen mit Configuratorrechten. Es kann vom Administrator und vom Configurator verändert werden. Wurde kein Passwort vergeben so ist public das gültige Passwort.Gelesen liefert diese Variable einen Null-Pointer." ::= { wtWebioAn2GraphSessCntrl 5 } -- wtWebioAn2GraphText Group ------------------------ wtWebioAn2GraphDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Webio's, der userdefinierbar ist." ::= { wtWebioAn2GraphText 1 } wtWebioAn2GraphDeviceText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Beschreibung des Webio's, die userdefinierbar ist." ::= { wtWebioAn2GraphText 2 } wtWebioAn2GraphDeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Aufstellort des Webio's, die userdefinierbar ist." ::= { wtWebioAn2GraphText 3 } wtWebioAn2GraphDeviceContact OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Kontactadresse im Servicefall des Webio's, die userdefinierbar ist." ::= { wtWebioAn2GraphText 4 } -- wtWebioAn2GraphTimeZone Group ---------------------------- wtWebioAn2GraphTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Stunden der Zeitzone (Winterzeit) in Bezug auf UTC." ::= { wtWebioAn2GraphTimeZone 1 } wtWebioAn2GraphTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Minuten der Zeitzone (Winterzeit) in Bezug auf UTC." ::= { wtWebioAn2GraphTimeZone 2 } wtWebioAn2GraphTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Timezone" ::= { wtWebioAn2GraphTimeZone 3 } wtWebioAn2GraphStTzOffsetHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Stunden der Zeitzone (Sommerzeit) in Bezug auf UTC." ::= { wtWebioAn2GraphTimeZone 4 } wtWebioAn2GraphStTzOffsetMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Offset Minuten der Zeitzone (Sommerzeit) in Bezug auf UTC." ::= { wtWebioAn2GraphTimeZone 5 } wtWebioAn2GraphStTzEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Summertime" ::= { wtWebioAn2GraphTimeZone 6 } wtWebioAn2GraphStTzStartMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartMonth-January(1), wtWebioAn2GraphStartMonth-February(2), wtWebioAn2GraphStartMonth-March(3), wtWebioAn2GraphStartMonth-April(4), wtWebioAn2GraphStartMonth-May(5), wtWebioAn2GraphStartMonth-June(6), wtWebioAn2GraphStartMonth-July(7), wtWebioAn2GraphStartMonth-August(8), wtWebioAn2GraphStartMonth-September(9), wtWebioAn2GraphStartMonth-October(10), wtWebioAn2GraphStartMonth-November(11), wtWebioAn2GraphStartMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Monat, in dem von Winterzeit auf Sommerzeit umgestellt wird." ::= { wtWebioAn2GraphTimeZone 7 } wtWebioAn2GraphStTzStartMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartMode-first(1), wtWebioAn2GraphStartMode-second(2), wtWebioAn2GraphStartMode-third(3), wtWebioAn2GraphStartMode-fourth(4), wtWebioAn2GraphStartMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Modus des Wochentages, bei dem von Winterzeit auf Sommerzeit umgestellt wird." ::= { wtWebioAn2GraphTimeZone 8 } wtWebioAn2GraphStTzStartWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStartWday-Sunday(1), wtWebioAn2GraphStartWday-Monday(2), wtWebioAn2GraphStartWday-Tuesday(3), wtWebioAn2GraphStartWday-Thursday(4), wtWebioAn2GraphStartWday-Wednesday(5), wtWebioAn2GraphStartWday-Friday(6), wtWebioAn2GraphStartWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Wochentag, bei dem von Winterzeit auf Sommerzeit umgestellt wird" ::= { wtWebioAn2GraphTimeZone 9 } wtWebioAn2GraphStTzStartHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Stunde, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird." ::= { wtWebioAn2GraphTimeZone 10 } wtWebioAn2GraphStTzStartMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute, in der die Zeitzone von Winter auf Sommerzeit in Bezug auf UTC umgestellt wird." ::= { wtWebioAn2GraphTimeZone 11 } wtWebioAn2GraphStTzStopMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopMonth-January(1), wtWebioAn2GraphStopMonth-February(2), wtWebioAn2GraphStopMonth-March(3), wtWebioAn2GraphStopMonth-April(4), wtWebioAn2GraphStopMonth-May(5), wtWebioAn2GraphStopMonth-June(6), wtWebioAn2GraphStopMonth-July(7), wtWebioAn2GraphStopMonth-August(8), wtWebioAn2GraphStopMonth-September(9), wtWebioAn2GraphStopMonth-October(10), wtWebioAn2GraphStopMonth-November(11), wtWebioAn2GraphStopMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Monat, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebioAn2GraphTimeZone 12 } wtWebioAn2GraphStTzStopMode OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopMode-first(1), wtWebioAn2GraphStopMode-second(2), wtWebioAn2GraphStopMode-third(3), wtWebioAn2GraphStopMode-fourth(4), wtWebioAn2GraphStopMode-last(5) } ACCESS read-write STATUS mandatory DESCRIPTION "Modus des Wochentages, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebioAn2GraphTimeZone 13 } wtWebioAn2GraphStTzStopWday OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphStopWday-Sunday(1), wtWebioAn2GraphStopWday-Monday(2), wtWebioAn2GraphStopWday-Tuesday(3), wtWebioAn2GraphStopWday-Thursday(4), wtWebioAn2GraphStopWday-Wednesday(5), wtWebioAn2GraphStopWday-Friday(6), wtWebioAn2GraphStopWday-Saturday(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Wochentage, bei dem von Sommerzeit auf Winterzeit umgestellt wird." ::= { wtWebioAn2GraphTimeZone 14 } wtWebioAn2GraphStTzStopHrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Stunde, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird." ::= { wtWebioAn2GraphTimeZone 15 } wtWebioAn2GraphStTzStopMin OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Minute, in der die Zeitzone von Sommer auf Winterzeit in Bezug auf UTC umgestellt wird." ::= { wtWebioAn2GraphTimeZone 16 } -- wtWebioAn2GraphTimeServer Group ---------------------------- wtWebioAn2GraphTimeServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse oder Name des 1. Time Servers in ASCII" ::= { wtWebioAn2GraphTimeServer 1 } wtWebioAn2GraphTimeServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse oder Name des 2. Time Servers in ASCII" ::= { wtWebioAn2GraphTimeServer 2 } wtWebioAn2GraphTsEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Bedingung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Apply Time Server" ::= { wtWebioAn2GraphTimeServer 3 } wtWebioAn2GraphTsSyncTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Die Abfrage der Timeserver erfolgt zu dieser vollen Stunde (0-23)." ::= { wtWebioAn2GraphTimeServer 4 } -- wtWebioAn2GraphDeviceClock Group ---------------------------- wtWebioAn2GraphClockHrs OBJECT-TYPE SYNTAX INTEGER (0..23) ACCESS read-write STATUS mandatory DESCRIPTION "Uhrzeit Stunde, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebioAn2GraphDeviceClock 1 } wtWebioAn2GraphClockMin OBJECT-TYPE SYNTAX INTEGER (0..59) ACCESS read-write STATUS mandatory DESCRIPTION "Uhrzeit Minute, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebioAn2GraphDeviceClock 2 } wtWebioAn2GraphClockDay OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Tag des Monats, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebioAn2GraphDeviceClock 3 } wtWebioAn2GraphClockMonth OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphClockMonth-January(1), wtWebioAn2GraphClockMonth-February(2), wtWebioAn2GraphClockMonth-March(3), wtWebioAn2GraphClockMonth-April(4), wtWebioAn2GraphClockMonth-May(5), wtWebioAn2GraphClockMonth-June(6), wtWebioAn2GraphClockMonth-July(7), wtWebioAn2GraphClockMonth-August(8), wtWebioAn2GraphClockMonth-September(9), wtWebioAn2GraphClockMonth-October(10), wtWebioAn2GraphClockMonth-November(11), wtWebioAn2GraphClockMonth-December(12) } ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Monat, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebioAn2GraphDeviceClock 4 } wtWebioAn2GraphClockYear OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Datum: Jahr, unter Berücksichtigung der Zeitzoneneinstellungen." ::= { wtWebioAn2GraphDeviceClock 5 } -- wtWebioAn2GraphNetwork Group ------------------------ wtWebioAn2GraphIpAddress OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Webio's" ::= { wtWebioAn2GraphNetwork 1 } wtWebioAn2GraphSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Subnetmask des Webio's" ::= { wtWebioAn2GraphNetwork 2 } wtWebioAn2GraphGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "Gateway des Webio's" ::= { wtWebioAn2GraphNetwork 3 } wtWebioAn2GraphDnsServer1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des 1. DNS Servers in ASCII" ::= { wtWebioAn2GraphNetwork 4 } wtWebioAn2GraphDnsServer2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des 2. DNS Servers in ASCII" ::= { wtWebioAn2GraphNetwork 5 } wtWebioAn2GraphAddConfig OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Zusatzkonfiguration (1=EIN): Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: BOOTP disable Bit 1: DHCP disable " ::= { wtWebioAn2GraphNetwork 6 } -- wtWebioAn2GraphHTTP Group -------------------------------- wtWebioAn2GraphStartup OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Legt die Startseite fest, nur eine Auswahl zulässig: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 2: user.htm Bit 1: home.htm Bit 0: index.htm" ::= { wtWebioAn2GraphHTTP 1 } wtWebioAn2GraphGetHeaderEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wenn freigeschaltet, wird eine Erkennungssequenz und /oder ein HTTP-Kopf nach jeder GET-Anfrage der Antwort vorangestellt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-6: ungenutzt Bit 1 : GET HTTP enable Bit 0 : GET Header enable" ::= { wtWebioAn2GraphHTTP 2 } wtWebioAn2GraphHttpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "HTTP Port, an den die TCP-Anfragen gesendet werden können (Default: 80)." ::= { wtWebioAn2GraphHTTP 3 } -- wtWebioAn2GraphMail Group -------------------------------- wtWebioAn2GraphMailAdName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Gerätename für die Mail-Administration." ::= { wtWebioAn2GraphMail 1 } wtWebioAn2GraphMailReply OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Reply-Adresse für den Mailserver." ::= { wtWebioAn2GraphMail 2 } wtWebioAn2GraphMailServer OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder Ip-Adresse des Mailservers." ::= { wtWebioAn2GraphMail 3 } wtWebioAn2GraphMailEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Erlaubt das versenden von Mails: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Mail enable" ::= { wtWebioAn2GraphMail 4 } wtWebioAn2GraphMailAuthentication OBJECT-TYPE SYNTAX OCTET STRING (SIZE (4)) ACCESS read-write STATUS mandatory DESCRIPTION "Auswahl des Authenticationmodi: die OCTETS werden bitweise interpretiert, es darf nur ein Bit gesetzt sein. Bit 0 entspricht dem LSB. OCTET 1: ungenutzt OCTET 2: ungenutzt OCTET 3: ungenutzt OCTET 4: Bit 3-7: ungenutzt Bit 2 : POP3 vor SMTP Bit 1 : ESMTP, Authentifizierung Bit 0 : SMTP, keine Authentifizierung" ::= { wtWebioAn2GraphMail 5 } wtWebioAn2GraphMailAuthUser OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Postfaches / Postfachusers." ::= { wtWebioAn2GraphMail 6 } wtWebioAn2GraphMailAuthPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Passwort zur Identifizierung des Users." ::= { wtWebioAn2GraphMail 7 } wtWebioAn2GraphMailPop3Server OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder Ip-Adresse des POP3 Servers." ::= { wtWebioAn2GraphMail 8 } -- wtWebioAn2GraphSNMP Group -------------------------------- wtWebioAn2GraphSnmpCommunityStringRead OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read only" ::= { wtWebioAn2GraphSNMP 1 } wtWebioAn2GraphSnmpCommunityStringReadWrite OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string read / write" ::= { wtWebioAn2GraphSNMP 2 } wtWebioAn2GraphSystemTrapManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des SNMP-Managers, der den System Trap entgegen nimmt." ::= { wtWebioAn2GraphSNMP 3 } wtWebioAn2GraphSystemTrapEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2-7: ungenutzt" ::= { wtWebioAn2GraphSNMP 4 } wtWebioAn2GraphSnmpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet SNMP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : SNMP enable" ::= { wtWebioAn2GraphSNMP 5 } wtWebioAn2GraphSnmpCommunityStringTrap OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Community string der Traps." ::= { wtWebioAn2GraphSNMP 6 } -- wtWebioAn2GraphUDP Group -------------------------------- wtWebioAn2GraphUdpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Udp Port, an den die Udp-Anfragen GET Single gesendet werden können" ::= { wtWebioAn2GraphUDP 1 } wtWebioAn2GraphUdpEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Schaltet UDP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : UDP enable" ::= { wtWebioAn2GraphUDP 2 } -- wtWebioAn2GraphSyslog Group -------------------------------- wtWebioAn2GraphSyslogServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des Syslog-Servers, der die Syslog-Nachricht entgegen nimmt." ::= { wtWebioAn2GraphSyslog 1 } wtWebioAn2GraphSyslogServerPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Syslog-Servers, default ist 514." ::= { wtWebioAn2GraphSyslog 2 } wtWebioAn2GraphSyslogSystemMessagesEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: ColdStart Bit 1: WarmStart Bit 2: Diag Messages Bit 3-7: ungenutzt" ::= { wtWebioAn2GraphSyslog 3 } wtWebioAn2GraphSyslogEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet Syslog frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Syslog enable" ::= { wtWebioAn2GraphSyslog 4 } -- wtWebioAn2GraphFTP Group -------------------------------- wtWebioAn2GraphFTPServerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des FTP-Servers, der die FTP-Nachricht entgegen nimmt." ::= { wtWebioAn2GraphFTP 1 } wtWebioAn2GraphFTPServerControlPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Kontrollports des FTP-Servers, default ist 21." ::= { wtWebioAn2GraphFTP 2 } wtWebioAn2GraphFTPUserName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Name des Anwenders." ::= { wtWebioAn2GraphFTP 3 } wtWebioAn2GraphFTPPassword OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Passwort des Anwenders." ::= { wtWebioAn2GraphFTP 4 } wtWebioAn2GraphFTPAccount OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "FTP Loggin: Account-Name des Anwenderkontos." ::= { wtWebioAn2GraphFTP 5 } wtWebioAn2GraphFTPOption OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet den FTP Server in den Passiv-Modus, der Client kontrolliert die Datenverbindung allein: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : PASV enable" ::= { wtWebioAn2GraphFTP 6 } wtWebioAn2GraphFTPEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet FTP frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : FTP enable" ::= { wtWebioAn2GraphFTP 7 } -- wtWebioAn2GraphDatalogger Group -------------------------------- wtWebioAn2GraphLoggerTimebase OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphDatalogger-1Min(1), wtWebioAn2GraphDatalogger-5Min(2), wtWebioAn2GraphDatalogger-15Min(3), wtWebioAn2GraphDatalogger-60Min(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Zeitbasis des Dataloggers" ::= { wtWebioAn2GraphDatalogger 1 } wtWebioAn2GraphLoggerSensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphDatalogger 2 } wtWebioAn2GraphDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Die hier ausgewählten Sensoren werden grafisch angezeigt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphDatalogger 3 } -- Graph Sensor Color Table wtWebioAn2GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Sensorfarben in der grafischen Darstellung." ::= { wtWebioAn2GraphDatalogger 4 } wtWebioAn2GraphSensorColorEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Sensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphSensorColorTable 1 } wtWebioAn2GraphSensorColorEntry ::= SEQUENCE { wtWebioAn2GraphSensorColor OCTET STRING } wtWebioAn2GraphSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe des Sensors in der grafischen Darstellung." ::= { wtWebioAn2GraphSensorColorEntry 1 } wtWebioAn2GraphAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bit 0 schaltet Vertical Auto Scale frei: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 1-7: ungenutzt Bit 0 : Auto Scale enable" ::= { wtWebioAn2GraphDatalogger 5 } wtWebioAn2GraphVerticalUpperLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die maximal sichtbare Temperatur für die grafische Darstellung. Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebioAn2GraphDatalogger 6 } wtWebioAn2GraphVerticalLowerLimit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Minal sichtbare Temperatur für die grafische Darstellung. Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebioAn2GraphDatalogger 7 } wtWebioAn2GraphHorizontalZoom OBJECT-TYPE SYNTAX INTEGER { wtWebioAn2GraphZoom-25Min(1), wtWebioAn2GraphZoom-75Min(2), wtWebioAn2GraphZoom-5Std(3), wtWebioAn2GraphZoom-30Std(4), wtWebioAn2GraphZoom-5Tage(5), wtWebioAn2GraphZoom-25Tage(6) } ACCESS read-write STATUS mandatory DESCRIPTION "Definiert den default Zoom." ::= { wtWebioAn2GraphDatalogger 8 } -- wtWebioAn2GraphAlarm Group ---------------------------- wtWebioAn2GraphAlarmCount OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der unabhängigen Alarme." ::= { wtWebioAn2GraphAlarm 1 } -- Alarm Interface Table wtWebioAn2GraphAlarmIfTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Alarmindizes." ::= { wtWebioAn2GraphAlarm 2 } wtWebioAn2GraphAlarmIfEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphAlarmIfEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Alarme." INDEX { wtWebioAn2GraphAlarmNo } ::= { wtWebioAn2GraphAlarmIfTable 1 } wtWebioAn2GraphAlarmIfEntry ::= SEQUENCE { wtWebioAn2GraphAlarmNo INTEGER } wtWebioAn2GraphAlarmNo OBJECT-TYPE SYNTAX INTEGER (1..2) ACCESS read-only STATUS mandatory DESCRIPTION "Nummer des Alarms." ::= { wtWebioAn2GraphAlarmIfEntry 1 } -- Alarm Table wtWebioAn2GraphAlarmTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Einstellungen abhängig von der Alarmnummer." ::= { wtWebioAn2GraphAlarm 3 } wtWebioAn2GraphAlarmEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphAlarmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Alarm-Parameter der einzelnen Alarme." INDEX { wtWebioAn2GraphAlarmNo } ::= { wtWebioAn2GraphAlarmTable 1 } wtWebioAn2GraphAlarmEntry ::= SEQUENCE { wtWebioAn2GraphAlarmTrigger OCTET STRING, wtWebioAn2GraphAlarmMin OCTET STRING, wtWebioAn2GraphAlarmMax OCTET STRING, wtWebioAn2GraphAlarmHysteresis OCTET STRING, wtWebioAn2GraphAlarmDelay OCTET STRING, wtWebioAn2GraphAlarmInterval OCTET STRING, wtWebioAn2GraphAlarmEnable OCTET STRING, wtWebioAn2GraphAlarmEMailAddr OCTET STRING, wtWebioAn2GraphAlarmMailSubject OCTET STRING, wtWebioAn2GraphAlarmMailText OCTET STRING, wtWebioAn2GraphAlarmManagerIP OCTET STRING, wtWebioAn2GraphAlarmTrapText OCTET STRING, wtWebioAn2GraphAlarmMailOptions OCTET STRING, wtWebioAn2GraphAlarmTcpIpAddr OCTET STRING, wtWebioAn2GraphAlarmTcpPort INTEGER, wtWebioAn2GraphAlarmTcpText OCTET STRING, wtWebioAn2GraphAlarmClearMailSubject OCTET STRING, wtWebioAn2GraphAlarmClearMailText OCTET STRING, wtWebioAn2GraphAlarmClearTrapText OCTET STRING, wtWebioAn2GraphAlarmClearTcpText OCTET STRING, wtWebioAn2GraphAlarmSyslogIpAddr OCTET STRING, wtWebioAn2GraphAlarmSyslogPort INTEGER, wtWebioAn2GraphAlarmSyslogText OCTET STRING, wtWebioAn2GraphAlarmSyslogClearText OCTET STRING, wtWebioAn2GraphAlarmFtpDataPort OCTET STRING, wtWebioAn2GraphAlarmFtpFileName OCTET STRING, wtWebioAn2GraphAlarmFtpText OCTET STRING, wtWebioAn2GraphAlarmFtpClearText OCTET STRING, wtWebioAn2GraphAlarmFtpOption OCTET STRING, wtWebioAn2GraphAlarmTimerCron OCTET STRING } wtWebioAn2GraphAlarmTrigger OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Triggerbedingungen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: Bit 0: Timer Bit 1: ColdStart Bit 2: WarmStart Bit 3: Sensor lost Bit 4-7 ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphAlarmEntry 1 } wtWebioAn2GraphAlarmMin OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Minimum Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebioAn2GraphAlarmEntry 2 } wtWebioAn2GraphAlarmMax OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Maximum Temperatur in Grad mit maximal 2 Nachkommastellen." ::= { wtWebioAn2GraphAlarmEntry 3 } wtWebioAn2GraphAlarmHysteresis OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bei Überschreiten der Temperatur Min+Hyst. und Unterschreiten der Temperatur Max-Hyst. wird der Alarm gelöscht: pos. Temperaturdifferenz in Grad mit maximal 2 Nachkommastellen." ::= { wtWebioAn2GraphAlarmEntry 4 } wtWebioAn2GraphAlarmDelay OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Der Alarm wird erst ausgelöst, wenn für die Dauer dieser Zeit die Alarmbedingungen erfüllt sind (Zeit in Minuten)." ::= { wtWebioAn2GraphAlarmEntry 5 } wtWebioAn2GraphAlarmInterval OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Sendeintervall von Alarmmeldungen." ::= { wtWebioAn2GraphAlarmEntry 6 } wtWebioAn2GraphAlarmEnable OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Alarmfreischaltung: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Mail Enable Bit 1: SNMP Trap enable Bit 2: TCP Client enable" ::= { wtWebioAn2GraphAlarmEntry 7 } wtWebioAn2GraphAlarmEMailAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "E-Mail Adresse, an die die Alarmmail gesendet werden soll." ::= { wtWebioAn2GraphAlarmEntry 8 } wtWebioAn2GraphAlarmMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Betreffzeile der Alarmmail." ::= { wtWebioAn2GraphAlarmEntry 9 } wtWebioAn2GraphAlarmMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Text der Alarmmail: liefert die aktuelle Temperatur; n = 1..2. liefert die aktuelle Zeit." ::= { wtWebioAn2GraphAlarmEntry 10 } wtWebioAn2GraphAlarmManagerIP OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name oder IP-Adresse des SNMP-Managers, der den Trap entgegen nimmt." ::= { wtWebioAn2GraphAlarmEntry 11 } wtWebioAn2GraphAlarmTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im Trapbody gesendet." ::= { wtWebioAn2GraphAlarmEntry 12 } wtWebioAn2GraphAlarmMailOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Attach Thermo.csv Enable Bit 1 : CSV-Data_since_last_report Bit 2-7: ungenutzt" ::= { wtWebioAn2GraphAlarmEntry 13 } wtWebioAn2GraphAlarmTcpIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Gerätes, dass eine TCP-Nachricht empfangen soll." ::= { wtWebioAn2GraphAlarmEntry 14 } wtWebioAn2GraphAlarmTcpPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Gerätes, dass eine TCP-Nachricht empfangen soll." ::= { wtWebioAn2GraphAlarmEntry 15 } wtWebioAn2GraphAlarmTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im TCP Trapbody gesendet." ::= { wtWebioAn2GraphAlarmEntry 16 } wtWebioAn2GraphAlarmClearMailSubject OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Betreffzeile der Alarm Clear Mail." ::= { wtWebioAn2GraphAlarmEntry 17 } wtWebioAn2GraphAlarmClearMailText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Text der Alarm Clear Mail: liefert die aktuelle Temperatur; n = 1..2. liefert die aktuelle Zeit." ::= { wtWebioAn2GraphAlarmEntry 18 } wtWebioAn2GraphAlarmClearTrapText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im Trapbody gesendet." ::= { wtWebioAn2GraphAlarmEntry 19 } wtWebioAn2GraphAlarmClearTcpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird im TCP Trapbody gesendet." ::= { wtWebioAn2GraphAlarmEntry 20 } wtWebioAn2GraphAlarmSyslogIpAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "IP-Adresse des Gerätes, dass eine Syslog-Nachricht empfangen soll." ::= { wtWebioAn2GraphAlarmEntry 21 } wtWebioAn2GraphAlarmSyslogPort OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "Portnummer des Gerätes, dass eine Syslog-Nachricht empfangen soll, default Port ist 514." ::= { wtWebioAn2GraphAlarmEntry 22 } wtWebioAn2GraphAlarmSyslogText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." ::= { wtWebioAn2GraphAlarmEntry 23 } wtWebioAn2GraphAlarmSyslogClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Jede Syslog-Nachricht beginnt mit einem Prioritätsschlüssel, einem Zeitstempel und der Host Ip-Nummer gemäß RFC3164. Dieser Text wird im darauf folgenden Syslog-Nachrichtenteil gesendet." ::= { wtWebioAn2GraphAlarmEntry 24 } wtWebioAn2GraphAlarmFtpDataPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Lokaler Datenport: 1..65535 oder AUTO: der nächste ungenutzte Port wird automatisch zugewiesen." ::= { wtWebioAn2GraphAlarmEntry 25 } wtWebioAn2GraphAlarmFtpFileName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Der File Name kann auch Pfadinformationen enthalten." ::= { wtWebioAn2GraphAlarmEntry 26 } wtWebioAn2GraphAlarmFtpText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird in die angegebene Datei geschrieben." ::= { wtWebioAn2GraphAlarmEntry 27 } wtWebioAn2GraphAlarmFtpClearText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Text wird in die angegebene Datei geschrieben." ::= { wtWebioAn2GraphAlarmEntry 28 } wtWebioAn2GraphAlarmFtpOptions OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen, nur eine Option darf eingeschaltet sein: STORE = Datei ersetzen APPEND = Nachrichten ans Dateiende anhängen Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : STORE Bit 1 : APPEND Bit 2-7: ungenutzt" ::= { wtWebioAn2GraphAlarmEntry 29 } wtWebioAn2GraphAlarmTimerCron OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Dieser Eintrag enthält 5 Leerzeichen- oder Tab-getrente Felder zur Definition von zeitgesteuerten Ausgabe von Alarmnachrichten. Jedes der 5 Felder muss mit der aktuelle Zeit übereinstimmen, um das Senden einer Nachricht auszulösen, Wochentag und Monatstag werden getrennt ausgewertet. Feld möglicher Zahlenbereich 1: Minuten 0-59 2. Stunden 0-23, 0 ist Mitternacht 3: Monatstag 1-31 4: Monat 1-12 5: Wochentag 0-6, 0 ist Sonntag Für jedes Feld kann nun angegeben werden: - eine ganze Zahl aus dem angegebenen Zahlenbereich - ein Teil-Zahlenbereich (wie z.B. 1-5) innerhalb des angegebenen Zahlenbereichs - eine mit Komma getrennte Liste von ganzen Zahlen oder Tei-Zahlenbereichen (wie z.B. 2,4-6,8,10) - ein Stern * (deckt den gesamten erlaubten Bereich ab) - ein / gibt die Schrittweite bei Teil-Zahlenbereichen an (z.B. 0-59/2 jede zweite Minute)." ::= { wtWebioAn2GraphAlarmEntry 30 } -- wtWebioAn2GraphGraphicsBase Group ---------------------------- wtWebioAn2GraphGraphicsBaseEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Legt die Anzeigeelemente der Grafik fest: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Auto scroll enable Bit 1 : Show table Bit 2 : Show graph Bit 3 : Show control buttons Bit 4 : Show config menu Bit 5-7: ungenutzt" ::= { wtWebioAn2GraphGraphicsBase 1 } wtWebioAn2GraphGraphicsBaseWidth OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Breite der Grafik in Pixeln." ::= { wtWebioAn2GraphGraphicsBase 2 } wtWebioAn2GraphGraphicsBaseHeight OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Höhe der Grafik in Pixeln." ::= { wtWebioAn2GraphGraphicsBase 3 } wtWebioAn2GraphGraphicsBaseFrameColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe des Rahmens in der grafischen Darstellung." ::= { wtWebioAn2GraphGraphicsBase 4 } wtWebioAn2GraphGraphicsBaseBackgroundColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe der Hintergrundfarbe in der grafischen Darstellung." ::= { wtWebioAn2GraphGraphicsBase 5 } wtWebioAn2GraphGraphicsBasePollingrate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Definiert die Abfragerate in Sekunden, mit der die Grafik aktualisiert wird." ::= { wtWebioAn2GraphGraphicsBase 6 } -- wtWebioAn2GraphGraphicsSelect Group ---------------------------- wtWebioAn2GraphGraphicsSelectDisplaySensorSel OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Die hier ausgewählten Sensoren werden grafisch angezeigt: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphGraphicsSelect 1 } wtWebioAn2GraphGraphicsSelectDisplayShowExtrem OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Die Anzeige von Minima und Maxima der hier ausgewählten Sensoren wird freigeschaltet: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0: Sensor 1 Bit 1: Sensor 2 Bit 2: Sensor 3 Bit 3: Sensor 4 Bit 4: Sensor 5 Bit 5: Sensor 6 Bit 6: Sensor 7 Bit 7: Sensor 8" ::= { wtWebioAn2GraphGraphicsSelect 2 } -- Graph Sensor Color Table wtWebioAn8GraphSensorColorTable OBJECT-TYPE SYNTAX SEQUENCE OF WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Sensorfarben in der grafischen Darstellung." ::= { wtWebioAn2GraphGraphicsSelect 3 } wtWebioAn8GraphSensorColorEntry OBJECT-TYPE SYNTAX WtWebioAn8GraphSensorColorEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Nummern der Sensoren." INDEX { wtWebioAn8GraphSensorNo } ::= { wtWebioAn8GraphSensorColorTable 1 } WtWebioAn8GraphSensorColorEntry ::= SEQUENCE { wtWebioAn2GraphGraphicsSensorColor OCTET STRING, wtWebioAn2GraphGraphicsSelectScale OCTET STRING } wtWebioAn2GraphGraphicsSensorColor OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3)) ACCESS read-write STATUS mandatory DESCRIPTION "Farbe des Sensors in der grafischen Darstellung." ::= { wtWebioAn8GraphSensorColorEntry 1 } wtWebioAn2GraphGraphicsSelectScale OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Zuweisung einer Skalierung zu einem Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Use Scale 1 Bit 1 : Use Scale 2 Bit 2 : Use Scale 3 Bit 3 : Use Scale 4 Bit 4-7: ungenutzt" ::= { wtWebioAn8GraphSensorColorEntry 2 } -- wtWebioAn2GraphGraphicsScale Group ---------------------------- wtWebioAn2GraphGraphicsScaleAutoScaleEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wählt den Auto Scale Modus für die jeweilige Skalierung aus: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Scale 1 Auto scale enable Bit 1 : Scale 2 Auto scale enable Bit 2 : Scale 3 Auto scale enable Bit 3 : Scale 4 Auto scale enable Bit 4-7: ungenutzt" ::= { wtWebioAn2GraphGraphicsScale 1 } wtWebioAn2GraphGraphicsScaleAutoFitEnable OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Wählt den Auto Fit Modus für die jeweilige Skalierung aus: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : Scale 1 Auto fit enable Bit 1 : Scale 2 Auto fit enable Bit 2 : Scale 3 Auto fit enable Bit 3 : Scale 4 Auto fit enable Bit 4-7: ungenutzt" ::= { wtWebioAn2GraphGraphicsScale 2 } wtWebioAn2GraphGraphicsScale1Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Minimum." ::= { wtWebioAn2GraphGraphicsScale 3 } wtWebioAn2GraphGraphicsScale2Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Minimum." ::= { wtWebioAn2GraphGraphicsScale 4 } wtWebioAn2GraphGraphicsScale3Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Minimum." ::= { wtWebioAn2GraphGraphicsScale 5 } wtWebioAn2GraphGraphicsScale4Min OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Minimum." ::= { wtWebioAn2GraphGraphicsScale 6 } wtWebioAn2GraphGraphicsScale1Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Maximum." ::= { wtWebioAn2GraphGraphicsScale 7 } wtWebioAn2GraphGraphicsScale2Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Maximum." ::= { wtWebioAn2GraphGraphicsScale 8 } wtWebioAn2GraphGraphicsScale3Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Maximum." ::= { wtWebioAn2GraphGraphicsScale 9 } wtWebioAn2GraphGraphicsScale4Max OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Maximum." ::= { wtWebioAn2GraphGraphicsScale 10 } wtWebioAn2GraphGraphicsScale1Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 1: Einheit." ::= { wtWebioAn2GraphGraphicsScale 11 } wtWebioAn2GraphGraphicsScale2Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 2: Einheit." ::= { wtWebioAn2GraphGraphicsScale 12 } wtWebioAn2GraphGraphicsScale3Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 3: Einheit." ::= { wtWebioAn2GraphGraphicsScale 13 } wtWebioAn2GraphGraphicsScale4Unit OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Skalierung 4: Einheit." ::= { wtWebioAn2GraphGraphicsScale 14 } -- wtWebioAn2GraphPorts Group ---------------------------- -- Table wtWebioAn2GraphPortTable OBJECT-TYPE SYNTAX SEQUENCE OF wtWebioAn2GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Liste der Einstellungen abhängig von der Sensornummer." ::= { wtWebioAn2GraphPorts 1 } wtWebioAn2GraphPortEntry OBJECT-TYPE SYNTAX wtWebioAn2GraphPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Sensor-Parameter der einzelnen Sensoren." INDEX { wtWebioAn2GraphSensorNo } ::= { wtWebioAn2GraphPortTable 1 } wtWebioAn2GraphPortEntry ::= SEQUENCE { wtWebioAn2GraphPortName OCTET STRING, wtWebioAn2GraphPortText OCTET STRING, wtWebioAn2GraphPortOffset1 OCTET STRING, wtWebioAn2GraphPortTemperature1 OCTET STRING, wtWebioAn2GraphPortOffset2 OCTET STRING, wtWebioAn2GraphPortTemperature2 OCTET STRING, wtWebioAn2GraphPortComment OCTET STRING, wtWebioAn2GraphPortSensorSelect OCTET STRING } wtWebioAn2GraphPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Name des Sensors." ::= { wtWebioAn2GraphPortEntry 1 } wtWebioAn2GraphPortText OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Beschreibung des Sensors." ::= { wtWebioAn2GraphPortEntry 2 } wtWebioAn2GraphPortOffset1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 1." ::= { wtWebioAn2GraphPortEntry 3 } wtWebioAn2GraphPortTemperature1 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Referenztemperatur 1 in Grad mit max. 2 Nachkommastellen." ::= { wtWebioAn2GraphPortEntry 4 } wtWebioAn2GraphPortOffset2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Offset in Grad mit max. 2 Nachkommastellen bei Temperatur 2." ::= { wtWebioAn2GraphPortEntry 5 } wtWebioAn2GraphPortTemperature2 OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Referenztemperatur 2 in Grad mit max. 2 Nachkommastellen." ::= { wtWebioAn2GraphPortEntry 6 } wtWebioAn2GraphPortComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Offset-Kalibrierung: Angaben zu Datum, Referenzgerät, Operator." ::= { wtWebioAn2GraphPortEntry 7 } wtWebioAn2GraphPortSensorSelect OBJECT-TYPE SYNTAX OCTET STRING (SIZE(4)) ACCESS read-write STATUS mandatory DESCRIPTION "Binär kodierte Optionen für Sensor: Octet 1: ungenutzt Octet 2: ungenutzt Octet 3: ungenutzt Octet 4: Bit 0 : PT100 Bit 1 : PT1000 (default) Bit 2-7: ungenutzt" ::= { wtWebioAn2GraphPortEntry 8 } -- wtWebioAn2GraphManufact Group ---------------------------- wtWebioAn2GraphMfName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hersteller Firmenname" ::= { wtWebioAn2GraphManufact 1 } wtWebioAn2GraphMfAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Adresse des Herstellers." ::= { wtWebioAn2GraphManufact 2 } wtWebioAn2GraphMfHotline OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Hotline des Herstellers." ::= { wtWebioAn2GraphManufact 3 } wtWebioAn2GraphMfInternet OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Internet-Adresse des Herstellers." ::= { wtWebioAn2GraphManufact 4 } wtWebioAn2GraphMfDeviceTyp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Gerätebezeichnung (Typ) des Herstellers." ::= { wtWebioAn2GraphManufact 5 } wtWebioAn2GraphMfOrderNo OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Bestellnummer des Gerätes des Herstellers." ::= { wtWebioAn2GraphManufact 6 } -- wtWebioAn2GraphDiag Group ---------------------------- wtWebioAn2GraphDiagErrorCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Anzahl der Einträge im Fehlerspeicher." ::= { wtWebioAn2GraphDiag 1 } wtWebioAn2GraphDiagBinaryError OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Bitweise kodierte Fehlerursachen." ::= { wtWebioAn2GraphDiag 2 } wtWebioAn2GraphDiagErrorIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Der Wert dieser Variable wird als Index für die Ausgabe eines Fehlertextes (wtWebioAn2GraphDiagErrorMessage) verwendet. Die Fehler im Speicher sind von 1 bis wtWebioAn2GraphDiagErrorCount durchnummeriert. Nach dem Schreiben einens gültigen Wertes in diese Variable kann der dazugehörige Text in wtWebioAn2GraphDiagErrorMessage ausgelesen werden." ::= { wtWebioAn2GraphDiag 3 } wtWebioAn2GraphDiagErrorMessage OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Abhängig vom Wert wtWebioAn2GraphDiagErrorIndex wird ein Fehlertext angezeigt." ::= { wtWebioAn2GraphDiag 4 } wtWebioAn2GraphDiagErrorClear OBJECT-TYPE SYNTAX INTEGER ACCESS write-only STATUS mandatory DESCRIPTION "Durch Schreiben eine 1 in diese Variable, wird der Fehlerspeicher gelöscht." ::= { wtWebioAn2GraphDiag 5 } -- TRAP DEFINITIONS -- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen wtWebioAn2GraphAlert1 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 1" --#SUMMARY "Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 21 wtWebioAn2GraphAlert2 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 2" --#SUMMARY "Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 22 wtWebioAn2GraphAlert3 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 3" --#SUMMARY "Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 23 wtWebioAn2GraphAlert4 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 4" --#SUMMARY "Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 24 wtWebioAn2GraphAlert5 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 5" --#SUMMARY "Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 25 wtWebioAn2GraphAlert6 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 6" --#SUMMARY "Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 26 wtWebioAn2GraphAlert7 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 7" --#SUMMARY "Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 27 wtWebioAn2GraphAlert8 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Alarm 8" --#SUMMARY "Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 28 wtWebioAn2GraphAlert9 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 1 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 1" --#SUMMARY "Release Alarm 1: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 81 wtWebioAn2GraphAlert10 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 2 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 2" --#SUMMARY "Release Alarm 2: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 82 wtWebioAn2GraphAlert11 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 3 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 3" --#SUMMARY "Release Alarm 3: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 83 wtWebioAn2GraphAlert12 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 4 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 4" --#SUMMARY "Release Alarm 4: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 84 wtWebioAn2GraphAlert13 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 5 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 5" --#SUMMARY "Release Alarm 5: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 85 wtWebioAn2GraphAlert14 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 6 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 6" --#SUMMARY "Release Alarm 6: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 86 wtWebioAn2GraphAlert15 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 7 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 7" --#SUMMARY "Release Alarm 7: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 87 wtWebioAn2GraphAlert16 TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphAlarmClearTrapText } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn der Alarm 8 gelöscht wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Release Alarm 8" --#SUMMARY "Release Alarm 8: %s" --#ARGUMENTS {0} --#SEVERITY INFORMATIONAL --#TIMEINDEX 99 --#STATE OPERATIONAL ::= 88 wtWebioAn2GraphAlertDiag TRAP-TYPE ENTERPRISE wtWebioAn2Graph VARIABLES { wtWebioAn2GraphDiagErrorIndex, wtWebioAn2GraphDiagErrorMessage } DESCRIPTION "Dieser SNMP-Trap wird generiert, wenn eine Diagnose/Error-Message ausgelöst wurde, das SNMP-Trap-Enable gesetzt ist und SNMP in Enable freigegeben ist." -- NMS trap annotation --#TYPE "Web-Thermograph Diagnose Error" --#SUMMARY "Diagnose error index: %d, Message: %s." --#ARGUMENTS {0,1} --#SEVERITY MAJOR --#TIMEINDEX 99 --#STATE DEGRADED ::= 110 END