From Andrew Holmes, 6 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. ===================================
  3. Version info:
  4. Commit SHA: f2c69f35d0ddd675542af5338e8956924ea783a4
  5. Commit Date: 1503552539
  6. DB Schema: 204
  7. PHP: 7.0.22-0ubuntu0.16.04.1
  8. MySQL: 10.0.31-MariaDB-0ubuntu0.16.04.2
  9. RRDTool: 1.5.5
  10. SNMP: NET-SNMP 5.7.3
  11. ==================================DEBUG!
  12. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE '$HOSTNAME' ORDER BY device_id DESC]
  13. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '25']
  14. $HOSTNAME 25 netonix SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','4.02','5.97','4.79','25',NOW())]
  15. SNMP Check response code: 0
  16.  
  17. Modules status: Global+ OS  Device  
  18. #### Load disco module os ####
  19. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
  20. Netonix WS-12-250-DC
  21.  
  22. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
  23. .*.4.1.46242
  24.  
  25. | Netonix WS-12-250-DC | .1.3.6.1.4.1.46242 |
  26.  
  27. >> Runtime for discovery module 'os': 0.1130 seconds with 848 bytes
  28. #### Unload disco module os ####
  29.  
  30. Modules status: Global+ OS  Device  
  31. #### Load disco module ports ####
  32. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ifDescr]
  33. ifDescr.1 = Port 1
  34. ifDescr.2 = Port 2
  35. ifDescr.3 = Port 3
  36. ifDescr.4 = Port 4
  37. ifDescr.5 = Port 5
  38. ifDescr.6 = Port 6
  39. ifDescr.7 = Port 7
  40. ifDescr.8 = Port 8
  41. ifDescr.9 = Port 9
  42. ifDescr.10 = Port 10
  43. ifDescr.11 = Port 11
  44. ifDescr.12 = Port 12
  45. ifDescr.13 = Port 13
  46. ifDescr.14 = Port 14
  47.  
  48. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ifName]
  49. ifName.1 = Port 1
  50. ifName.2 = Port 2
  51. ifName.3 = Port 3
  52. ifName.4 = Port 4
  53. ifName.5 = Port 5
  54. ifName.6 = Port 6
  55. ifName.7 = Port 7
  56. ifName.8 = Port 8
  57. ifName.9 = Port 9
  58. ifName.10 = Port 10
  59. ifName.11 = Port 11
  60. ifName.12 = Port 12
  61. ifName.13 = Port 13
  62. ifName.14 = Port 14
  63.  
  64. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ifAlias]
  65. <snip>
  66.  
  67. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ifType]
  68. ifType.1 = ethernetCsmacd
  69. ifType.2 = ethernetCsmacd
  70. ifType.3 = ethernetCsmacd
  71. ifType.4 = ethernetCsmacd
  72. ifType.5 = ethernetCsmacd
  73. ifType.6 = ethernetCsmacd
  74. ifType.7 = ethernetCsmacd
  75. ifType.8 = ethernetCsmacd
  76. ifType.9 = ethernetCsmacd
  77. ifType.10 = ethernetCsmacd
  78. ifType.11 = ethernetCsmacd
  79. ifType.12 = ethernetCsmacd
  80. ifType.13 = ethernetCsmacd
  81. ifType.14 = ethernetCsmacd
  82.  
  83. Array
  84. (
  85.     [1] => Array
  86.         (
  87.             [ifDescr] => Port 1
  88.             [ifName] => Port 1
  89.             [ifAlias] => CMP-BH14 AF
  90.             [ifType] => ethernetCsmacd
  91.         )
  92.  
  93.     [2] => Array
  94.         (
  95.             [ifDescr] => Port 2
  96.             [ifName] => Port 2
  97.             [ifAlias] => Port 2
  98.             [ifType] => ethernetCsmacd
  99.         )
  100.  
  101.     [3] => Array
  102.         (
  103.             [ifDescr] => Port 3
  104.             [ifName] => Port 3
  105.             [ifAlias] => CMP-BH13 CMPCRG
  106.             [ifType] => ethernetCsmacd
  107.         )
  108.  
  109.     [4] => Array
  110.         (
  111.             [ifDescr] => Port 4
  112.             [ifName] => Port 4
  113.             [ifAlias] => CMP-BH15 CMPGVL
  114.             [ifType] => ethernetCsmacd
  115.         )
  116.  
  117.     [5] => Array
  118.         (
  119.             [ifDescr] => Port 5
  120.             [ifName] => Port 5
  121.             [ifAlias] => CMP-BH12 CMPHUM
  122.             [ifType] => ethernetCsmacd
  123.         )
  124.  
  125.     [6] => Array
  126.         (
  127.             [ifDescr] => Port 6
  128.             [ifName] => Port 6
  129.             [ifAlias] => Port 6
  130.             [ifType] => ethernetCsmacd
  131.         )
  132.  
  133.     [7] => Array
  134.         (
  135.             [ifDescr] => Port 7
  136.             [ifName] => Port 7
  137.             [ifAlias] => CMP-AP21
  138.             [ifType] => ethernetCsmacd
  139.         )
  140.  
  141.     [8] => Array
  142.         (
  143.             [ifDescr] => Port 8
  144.             [ifName] => Port 8
  145.             [ifAlias] => CMP-AP22
  146.             [ifType] => ethernetCsmacd
  147.         )
  148.  
  149.     [9] => Array
  150.         (
  151.             [ifDescr] => Port 9
  152.             [ifName] => Port 9
  153.             [ifAlias] => CMP-AP23
  154.             [ifType] => ethernetCsmacd
  155.         )
  156.  
  157.     [10] => Array
  158.         (
  159.             [ifDescr] => Port 10
  160.             [ifName] => Port 10
  161.             [ifAlias] => Management
  162.             [ifType] => ethernetCsmacd
  163.         )
  164.  
  165.     [11] => Array
  166.         (
  167.             [ifDescr] => Port 11
  168.             [ifName] => Port 11
  169.             [ifAlias] => Port 11
  170.             [ifType] => ethernetCsmacd
  171.         )
  172.  
  173.     [12] => Array
  174.         (
  175.             [ifDescr] => Port 12
  176.             [ifName] => Port 12
  177.             [ifAlias] => Port 12
  178.             [ifType] => ethernetCsmacd
  179.         )
  180.  
  181.     [13] => Array
  182.         (
  183.             [ifDescr] => Port 13
  184.             [ifName] => Port 13
  185.             [ifAlias] => SFP1
  186.             [ifType] => ethernetCsmacd
  187.         )
  188.  
  189.     [14] => Array
  190.         (
  191.             [ifDescr] => Port 14
  192.             [ifName] => Port 14
  193.             [ifAlias] => SFP2
  194.             [ifType] => ethernetCsmacd
  195.         )
  196.  
  197. )
  198. SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
  199. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' ORDER BY port_id]
  200. ..............
  201.  
  202. >> Runtime for discovery module 'ports': 0.3820 seconds with 2096 bytes
  203. #### Unload disco module ports ####
  204.  
  205. Modules status: Global+ OS  Device  
  206. #### Load disco module ports-stack ####
  207. SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '25']
  208. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ifStackStatus]
  209.  
  210.  
  211.  
  212. >> Runtime for discovery module 'ports-stack': 0.0130 seconds with 640 bytes
  213. #### Unload disco module ports-stack ####
  214.  
  215. Modules status: Global+ OS  Device  
  216. #### Load disco module entity-physical ####
  217.  
  218. Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhysicalEntry]
  219. entPhysicalEntry = No Such Object available on this agent at this OID
  220.  
  221.  entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entAliasMappingIdentifier]
  222. entAliasMappingIdentifier = No Such Object available on this agent at this OID
  223.  
  224.  
  225. SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '25']
  226.  
  227. >> Runtime for discovery module 'entity-physical': 0.0860 seconds with 2928 bytes
  228. #### Unload disco module entity-physical ####
  229.  
  230. Modules status: Global+ OS  Device  
  231. #### Load disco module processors ####
  232.  hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrDevice]
  233. hrDevice = No Such Object available on this agent at this OID
  234.  
  235. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrProcessorLoad]
  236. hrProcessorLoad = No Such Object available on this agent at this OID
  237.  
  238. NETONIX : SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OvQ -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 UCD-SNMP-MIB::ssCpuIdle.0]
  239. 51
  240.  
  241. Discover Processor: 0, 0, ucd-old, CPU, 1, 49, ,
  242. SQL[SELECT COUNT(processor_id) FROM `processors` WHERE `processor_index` = '0' AND `device_id` = '25' AND `processor_type` = 'ucd-old']
  243. .SQL[UPDATE `processors` set `processor_descr` ='CPU',`processor_oid` ='0',`processor_usage` ='49',`processor_precision` ='1' WHERE `device_id`='25' AND `processor_index`='0' AND `processor_type`='ucd-old']
  244. SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '25' AND `processor_type` != 'ucd-old']
  245. Array
  246. (
  247.     [ucd-old] => Array
  248.         (
  249.             [0] => 1
  250.         )
  251.  
  252. )
  253. SQL[SELECT * FROM `processors` WHERE `device_id`  = '25']
  254. 0 -> ucd-old
  255.  
  256.  
  257. >> Runtime for discovery module 'processors': 0.1310 seconds with 39872 bytes
  258. #### Unload disco module processors ####
  259.  
  260. Modules status: Global+ OS  Device  
  261. #### Load disco module mempools ####
  262. SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '25' AND `mempool_type` = 'cemp']
  263. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal]
  264. hpLocalMem = No Such Object available on this agent at this OID
  265.  
  266. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal]
  267. hpGlobalMem = No Such Object available on this agent at this OID
  268.  
  269. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrStorageEntry]
  270. hrStorageEntry = No Such Object available on this agent at this OID
  271.  
  272. NETONIX : SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OvQU -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 UCD-SNMP-MIB::memTotalFree.0]
  273. 76792
  274.  
  275. Discover Mempool: 0, netonix, Memory, 1024, ,
  276. SQL[SELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '0' AND `device_id` = '25' AND `mempool_type` = 'netonix']
  277. .SQL[UPDATE `mempools` set `mempool_descr` ='Memory' WHERE device_id='25' AND mempool_index='0' AND mempool_type='netonix']
  278. Array
  279. (
  280.     [netonix] => Array
  281.         (
  282.             [0] => 1
  283.         )
  284.  
  285. )
  286. SQL[SELECT * FROM `mempools` WHERE `device_id`  = '25']
  287. 0 -> netonix
  288.  
  289.  
  290. >> Runtime for discovery module 'mempools': 0.1290 seconds with 24824 bytes
  291. #### Unload disco module mempools ####
  292.  
  293. Modules status: Global+ OS  Device  
  294. #### Load disco module cisco-vrf-lite ####
  295. SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '25' ]
  296.  
  297. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1568 bytes
  298. #### Unload disco module cisco-vrf-lite ####
  299.  
  300. Modules status: Global- OS  Device  Module [ cisco-mac-accounting ] disabled globally.
  301.  
  302. Modules status: Global- OS  Device  Module [ cisco-pw ] disabled globally.
  303.  
  304. Modules status: Global- OS  Device  Module [ cisco-vrf ] disabled globally.
  305.  
  306. Modules status: Global- OS  Device  Module [ cisco-cef ] disabled globally.
  307.  
  308. Modules status: Global- OS  Device  Module [ cisco-sla ] disabled globally.
  309.  
  310. Modules status: Global- OS  Device  Module [ cisco-cbqos ] disabled globally.
  311.  
  312. Modules status: Global- OS  Device  Module [ cisco-otv ] disabled globally.
  313.  
  314. Modules status: Global+ OS  Device  
  315. #### Load disco module ipv4-addresses ####
  316. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipAdEntIfIndex]
  317. ipAdEntIfIndex No Such Object available on this agent at this OID
  318.  
  319. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipAdEntNetMask.]
  320. No Such Object available on this agent at this OID
  321.  
  322. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '25' AND `ifIndex` = '']
  323. !SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '25' OR `ports`.`device_id` IS NULL]
  324.  
  325.  
  326. >> Runtime for discovery module 'ipv4-addresses': 0.0720 seconds with 29856 bytes
  327. #### Unload disco module ipv4-addresses ####
  328.  
  329. Modules status: Global+ OS  Device  
  330. #### Load disco module ipv6-addresses ####
  331. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
  332. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  333.  
  334. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipv6AddrPfxLength]
  335. .*.*.8.1.2 No Such Object available on this agent at this OID
  336.  
  337. SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '25' OR `ports`.`device_id` IS NULL]
  338.  
  339.  
  340. >> Runtime for discovery module 'ipv6-addresses': 0.0610 seconds with 6848 bytes
  341. #### Unload disco module ipv6-addresses ####
  342.  
  343. Modules status: Global- OS  Device  Module [ route ] disabled globally.
  344.  
  345. Modules status: Global+ OS  Device  
  346. #### Load disco module sensors ####
  347. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OeQUs -Ih -m NETONIX-SWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 poeStatusTable]
  348. poeStatus.1 = "48VH"
  349. poeStatus.2 = "Off"
  350. poeStatus.3 = "24V"
  351. poeStatus.4 = "24V"
  352. poeStatus.5 = "24V"
  353. poeStatus.6 = "Off"
  354. poeStatus.7 = "48V"
  355. poeStatus.8 = "48V"
  356. poeStatus.9 = "48V"
  357. poeStatus.10 = "Off"
  358. poeStatus.11 = "Off"
  359. poeStatus.12 = "Off"
  360. poeStatus.13 = "Off"
  361. poeStatus.14 = "Off"
  362.  
  363.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhysicalDescr]
  364. entPhysicalDescr = No Such Object available on this agent at this OID
  365.  
  366.  entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhysicalName]
  367. entPhysicalName = No Such Object available on this agent at this OID
  368.  
  369.  entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhySensorType]
  370. entPhySensorType = No Such Object available on this agent at this OID
  371.  
  372.  entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhySensorScale]
  373. entPhySensorScale = No Such Object available on this agent at this OID
  374.  
  375.  entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhySensorPrecision]
  376. entPhySensorPrecision = No Such Object available on this agent at this OID
  377.  
  378.  entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 entPhySensorValue]
  379. entPhySensorValue = No Such Object available on this agent at this OID
  380.  
  381.  
  382. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '25' AND `attrib_type` = 'ipmi_hostname' ]
  383. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'ipmi']
  384. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'ipmi']
  385. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'ipmi']
  386. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'ipmi']
  387. Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  388.  
  389. Current: Netonix: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 .1.3.6.1.4.1.46242.7.0]
  390. 27
  391.  
  392. Discover sensor: .1.3.6.1.4.1.46242.7.0, 0, netonix, DC Input Current, snmp, 10, 1, , 2.7
  393. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '0']
  394. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '0']
  395. .Array
  396. (
  397.     [netonix] => Array
  398.         (
  399.             [0] => 1
  400.         )
  401.  
  402. )
  403. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  404. 0 -> netonix
  405.  
  406. Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  407.  
  408. Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  409.  
  410. Fanspeed: Netonix: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETONIX-SWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/netonix udp:HOSTNAME:161 fanTable]
  411. fanIndex.1 = 1
  412. fanSpeed.1 = 2220
  413.  
  414. Discover sensor: .1.3.6.1.4.1.46242.2.1.2.1, 1, netonix, Fan 1, snmp, 1, 1, , 2220
  415. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'fanspeed' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '1']
  416. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'fanspeed' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '1']
  417. .Array
  418. (
  419.     [netonix] => Array
  420.         (
  421.             [1] => 1
  422.         )
  423.  
  424. )
  425. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  426. 1 -> netonix
  427.  
  428. Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  429.  
  430. Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  431.  
  432. Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  433.  
  434. Power: Netonix: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 .1.3.6.1.4.1.46242.6.0]
  435. 683
  436.  
  437. Discover sensor: .1.3.6.1.4.1.46242.6.0, 0, netonix, Total Consumption, snmp, 10, 1, , 68.3
  438. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'power' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '0']
  439. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'power' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '0']
  440. .Array
  441. (
  442.     [netonix] => Array
  443.         (
  444.             [0] => 1
  445.         )
  446.  
  447. )
  448. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  449. 0 -> netonix
  450.  
  451. Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  452.  
  453. Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  454.  
  455. State: Final sensor value: 5
  456. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  457. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  458. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.1, 1, netonixPoeStatus, Port 1 PoE, snmp, 1, 1, , 5
  459. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '1']
  460. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '1']
  461. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '1']
  462. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  463. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('245','3')]
  464. Final sensor value: 1
  465. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  466. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  467. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.2, 2, netonixPoeStatus, Port 2 PoE, snmp, 1, 1, , 1
  468. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '2']
  469. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '2']
  470. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '2']
  471. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  472. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('246','3')]
  473. Final sensor value: 2
  474. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  475. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  476. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.3, 3, netonixPoeStatus, Port 3 PoE, snmp, 1, 1, , 2
  477. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '3']
  478. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '3']
  479. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '3']
  480. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  481. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('247','3')]
  482. Final sensor value: 2
  483. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  484. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  485. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.4, 4, netonixPoeStatus, Port 4 PoE, snmp, 1, 1, , 2
  486. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '4']
  487. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '4']
  488. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '4']
  489. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  490. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('248','3')]
  491. Final sensor value: 2
  492. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  493. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  494. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.5, 5, netonixPoeStatus, Port 5 PoE, snmp, 1, 1, , 2
  495. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '5']
  496. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '5']
  497. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '5']
  498. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  499. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('249','3')]
  500. Final sensor value: 1
  501. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  502. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  503. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.6, 6, netonixPoeStatus, Port 6 PoE, snmp, 1, 1, , 1
  504. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '6']
  505. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '6']
  506. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '6']
  507. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  508. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('250','3')]
  509. Final sensor value: 3
  510. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  511. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  512. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.7, 7, netonixPoeStatus, Port 7 PoE, snmp, 1, 1, , 3
  513. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '7']
  514. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '7']
  515. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '7']
  516. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  517. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('251','3')]
  518. Final sensor value: 3
  519. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  520. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  521. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.8, 8, netonixPoeStatus, Port 8 PoE, snmp, 1, 1, , 3
  522. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '8']
  523. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '8']
  524. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '8']
  525. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  526. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('252','3')]
  527. Final sensor value: 3
  528. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  529. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  530. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.9, 9, netonixPoeStatus, Port 9 PoE, snmp, 1, 1, , 3
  531. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '9']
  532. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '9']
  533. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '9']
  534. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  535. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('253','3')]
  536. Final sensor value: 1
  537. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  538. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  539. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.10, 10, netonixPoeStatus, Port 10 PoE, snmp, 1, 1, , 1
  540. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '10']
  541. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '10']
  542. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '10']
  543. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  544. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('254','3')]
  545. Final sensor value: 1
  546. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  547. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  548. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.11, 11, netonixPoeStatus, Port 11 PoE, snmp, 1, 1, , 1
  549. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '11']
  550. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '11']
  551. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '11']
  552. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  553. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('255','3')]
  554. Final sensor value: 1
  555. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  556. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  557. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.12, 12, netonixPoeStatus, Port 12 PoE, snmp, 1, 1, , 1
  558. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '12']
  559. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '12']
  560. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '12']
  561. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  562. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('256','3')]
  563. Final sensor value: 1
  564. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  565. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  566. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.13, 13, netonixPoeStatus, Port 13 PoE, snmp, 1, 1, , 1
  567. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '13']
  568. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '13']
  569. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '13']
  570. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  571. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('257','3')]
  572. Final sensor value: 1
  573. SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = 'netonixPoeStatus' LIMIT 1]
  574. SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='3']
  575. Discover sensor: .1.3.6.1.4.1.46242.5.1.2.14, 14, netonixPoeStatus, Port 14 PoE, snmp, 1, 1, , 1
  576. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '25' AND sensor_type = 'netonixPoeStatus' AND `sensor_index` = '14']
  577. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '14']
  578. .SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '25' AND `sensor_type` = 'netonixPoeStatus' AND `sensor_index` = '14']
  579. SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'netonixPoeStatus']
  580. SQL[INSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('258','3')]
  581. Array
  582. (
  583.     [netonixPoeStatus] => Array
  584.         (
  585.             [1] => 1
  586.             [2] => 1
  587.             [3] => 1
  588.             [4] => 1
  589.             [5] => 1
  590.             [6] => 1
  591.             [7] => 1
  592.             [8] => 1
  593.             [9] => 1
  594.             [10] => 1
  595.             [11] => 1
  596.             [12] => 1
  597.             [13] => 1
  598.             [14] => 1
  599.         )
  600.  
  601. )
  602. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  603. 1 -> netonixPoeStatus
  604. 2 -> netonixPoeStatus
  605. 3 -> netonixPoeStatus
  606. 4 -> netonixPoeStatus
  607. 5 -> netonixPoeStatus
  608. 6 -> netonixPoeStatus
  609. 7 -> netonixPoeStatus
  610. 8 -> netonixPoeStatus
  611. 9 -> netonixPoeStatus
  612. 10 -> netonixPoeStatus
  613. 11 -> netonixPoeStatus
  614. 12 -> netonixPoeStatus
  615. 13 -> netonixPoeStatus
  616. 14 -> netonixPoeStatus
  617.  
  618. Temperature: Netonix: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETONIX-SWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/netonix udp:HOSTNAME:161 tempTable]
  619. tempIndex.1 = 1
  620. tempIndex.2 = 2
  621. tempIndex.3 = 3
  622. tempIndex.4 = 4
  623. tempIndex.5 = 5
  624. tempIndex.6 = 6
  625. tempIndex.7 = 7
  626. tempDescription.1 = Board Temp
  627. tempDescription.2 = CPU Temp
  628. tempDescription.3 = PHY Temp
  629. tempDescription.4 = DCDC Board Temp
  630. tempDescription.5 = DCDC Heatsink #1 Temp
  631. tempDescription.6 = DCDC Heatsink #2 Temp
  632. tempDescription.7 = DCDC Controller Temp
  633. temp.1 = 39
  634. temp.2 = 72
  635. temp.3 = 80
  636. temp.4 = 29
  637. temp.5 = 28
  638. temp.6 = 28
  639. temp.7 = 43
  640.  
  641. Discover sensor: .1.3.6.1.4.1.46242.3.1.3.1, 1, netonix, Board Temp, snmp, 1, 1, , 39
  642. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '1']
  643. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '1']
  644. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.2, 2, netonix, CPU Temp, snmp, 1, 1, , 72
  645. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '2']
  646. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '2']
  647. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.3, 3, netonix, PHY Temp, snmp, 1, 1, , 80
  648. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '3']
  649. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '3']
  650. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.4, 4, netonix, DCDC Board Temp, snmp, 1, 1, , 29
  651. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '4']
  652. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '4']
  653. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.5, 5, netonix, DCDC Heatsink #1 Temp, snmp, 1, 1, , 28
  654. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '5']
  655. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '5']
  656. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.6, 6, netonix, DCDC Heatsink #2 Temp, snmp, 1, 1, , 28
  657. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '6']
  658. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '6']
  659. .Discover sensor: .1.3.6.1.4.1.46242.3.1.3.7, 7, netonix, DCDC Controller Temp, snmp, 1, 1, , 43
  660. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '7']
  661. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '7']
  662. .Array
  663. (
  664.     [netonix] => Array
  665.         (
  666.             [1] => 1
  667.             [2] => 1
  668.             [3] => 1
  669.             [4] => 1
  670.             [5] => 1
  671.             [6] => 1
  672.             [7] => 1
  673.         )
  674.  
  675. )
  676. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  677. 1 -> netonix
  678. 2 -> netonix
  679. 3 -> netonix
  680. 4 -> netonix
  681. 5 -> netonix
  682. 6 -> netonix
  683. 7 -> netonix
  684.  
  685. Voltage: Netonix: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETONIX-SWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/netonix udp:HOSTNAME:161 voltageTable]
  686. voltageIndex.1 = 1
  687. voltageIndex.2 = 2
  688. voltageIndex.3 = 3
  689. voltageIndex.4 = 4
  690. voltageIndex.5 = 5
  691. voltageDescription.1 = Board 48V
  692. voltageDescription.2 = Board 24V
  693. voltageDescription.3 = Board 3V
  694. voltageDescription.4 = DCDC Input Voltage
  695. voltageDescription.5 = DCDC Output Voltage
  696. voltage.1 = 48.20
  697. voltage.2 = 24.80
  698. voltage.3 = 3.30
  699. voltage.4 = 27.30
  700. voltage.5 = 49.60
  701.  
  702. Discover sensor: .1.3.6.1.4.1.46242.4.1.3.1, 1, netonix, Board 48V, snmp, 100, 1, , 48.20
  703. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '1']
  704. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '1']
  705. .Discover sensor: .1.3.6.1.4.1.46242.4.1.3.2, 2, netonix, Board 24V, snmp, 100, 1, , 24.80
  706. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '2']
  707. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '2']
  708. .Discover sensor: .1.3.6.1.4.1.46242.4.1.3.3, 3, netonix, Board 3V, snmp, 100, 1, , 3.30
  709. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '3']
  710. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '3']
  711. .Discover sensor: .1.3.6.1.4.1.46242.4.1.3.4, 4, netonix, DCDC Input Voltage, snmp, 100, 1, , 27.30
  712. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '4']
  713. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '4']
  714. .Discover sensor: .1.3.6.1.4.1.46242.4.1.3.5, 5, netonix, DCDC Output Voltage, snmp, 100, 1, , 49.60
  715. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '25' AND sensor_type = 'netonix' AND `sensor_index` = '5']
  716. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '25' AND `sensor_type` = 'netonix' AND `sensor_index` = '5']
  717. .Array
  718. (
  719.     [netonix] => Array
  720.         (
  721.             [1] => 1
  722.             [2] => 1
  723.             [3] => 1
  724.             [4] => 1
  725.             [5] => 1
  726.         )
  727.  
  728. )
  729. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  730. 1 -> netonix
  731. 2 -> netonix
  732. 3 -> netonix
  733. 4 -> netonix
  734. 5 -> netonix
  735.  
  736. Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '25' AND S.poller_type = 'snmp']
  737.  
  738.  
  739. >> Runtime for discovery module 'sensors': 0.4360 seconds with 19440 bytes
  740. #### Unload disco module sensors ####
  741.  
  742. Modules status: Global+ OS  Device  
  743. #### Load disco module storage ####
  744. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry]
  745. eqliscsiVolumeEntry = No Such Object available on this agent at this OID
  746.  
  747. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrStorageEntry]
  748. hrStorageEntry = No Such Object available on this agent at this OID
  749.  
  750. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dfEntry]
  751. dfEntry = No Such Object available on this agent at this OID
  752.  
  753. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dskTable]
  754. dskIndex.1 = 1
  755. dskPath.1 = /jffs
  756. dskDevice.1 = /dev/mtdblock6
  757. dskMinimum.1 = -1
  758. dskMinPercent.1 = -1
  759. dskTotal.1 = 4352
  760. dskAvail.1 = 3108
  761. dskUsed.1 = 1244
  762. dskPercent.1 = 29
  763. dskPercentNode.1 = 100
  764. dskErrorFlag.1 = noError
  765. dskErrorMsg.1 =
  766.  
  767. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id`  = '25' AND `storage_type` != 'dsk']
  768. Discover Storage: 1, dsk, ucd-dsktable, /jffs, 4456448, 1024, 4456448
  769. SQL[SELECT * FROM `storage` WHERE `storage_index` = '1' AND `device_id` = '25' AND `storage_mib` = 'ucd-dsktable']
  770. SQL[UPDATE `storage` set `storage_descr` ='/jffs',`storage_type` ='dsk',`storage_units` ='1024',`storage_size` ='4456448' WHERE `device_id` = '25' AND `storage_index` = '1' AND `storage_mib` = 'ucd-dsktable']
  771. .Array
  772. (
  773.     [ucd-dsktable] => Array
  774.         (
  775.             [1] => 1
  776.         )
  777.  
  778. )
  779. SQL[SELECT * FROM `storage` WHERE `device_id`  = '25']
  780. 1 -> ucd-dsktable
  781.  
  782.  
  783. >> Runtime for discovery module 'storage': 0.1950 seconds with 7616 bytes
  784. #### Unload disco module storage ####
  785.  
  786. Modules status: Global+ OS  Device  
  787. #### Load disco module hr-device ####
  788. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrDeviceEntry]
  789. hrDeviceEntry = No Such Object available on this agent at this OID
  790.  
  791. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 hrProcessorEntry]
  792. hrProcessorEntry = No Such Object available on this agent at this OID
  793.  
  794. Array
  795. (
  796. )
  797. SQL[SELECT * FROM `hrDevice` WHERE `device_id`  = '25']
  798.  
  799.  
  800. >> Runtime for discovery module 'hr-device': 0.0470 seconds with 840 bytes
  801. #### Unload disco module hr-device ####
  802.  
  803. Modules status: Global+ OS  Device  
  804. #### Load disco module discovery-protocols ####
  805.  CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 cdpCache]
  806. cdpCacheIfIndex.10.1 = 10
  807. cdpCacheIfIndex.5.2 = 5
  808. cdpCacheIfIndex.5.3 = 5
  809. cdpCacheIfIndex.1.4 = 1
  810. cdpCacheIfIndex.4.5 = 4
  811. cdpCacheIfIndex.3.6 = 3
  812. cdpCacheIfIndex.4.7 = 4
  813. cdpCacheIfIndex.4.8 = 4
  814. cdpCacheIfIndex.4.9 = 4
  815. cdpCacheIfIndex.4.10 = 4
  816. cdpCacheIfIndex.4.11 = 4
  817. cdpCacheIfIndex.4.12 = 4
  818. cdpCacheDeviceIndex.10.1 = 1
  819. cdpCacheDeviceIndex.5.2 = 2
  820. cdpCacheDeviceIndex.5.3 = 3
  821. cdpCacheDeviceIndex.1.4 = 4
  822. cdpCacheDeviceIndex.4.5 = 5
  823. cdpCacheDeviceIndex.3.6 = 6
  824. cdpCacheDeviceIndex.4.7 = 7
  825. cdpCacheDeviceIndex.4.8 = 8
  826. cdpCacheDeviceIndex.4.9 = 9
  827. cdpCacheDeviceIndex.4.10 = 10
  828. cdpCacheDeviceIndex.4.11 = 11
  829. cdpCacheDeviceIndex.4.12 = 12
  830. cdpCacheAddressType.10.1 = ip
  831. cdpCacheAddressType.5.2 = ip
  832. cdpCacheAddressType.5.3 = ip
  833. cdpCacheAddressType.1.4 = ip
  834. cdpCacheAddressType.4.5 = ip
  835. cdpCacheAddressType.3.6 = ip
  836. cdpCacheAddressType.4.7 = ip
  837. cdpCacheAddressType.4.8 = ip
  838. cdpCacheAddressType.4.9 = ip
  839. cdpCacheAddressType.4.10 = ip
  840. cdpCacheAddressType.4.11 = ip
  841. cdpCacheAddressType.4.12 = ip
  842. cdpCacheAddress.10.1 = "AC 14 11 02 "
  843. cdpCacheAddress.5.2 = "AC 10 09 03 "
  844. cdpCacheAddress.5.3 = "AC 14 15 01 "
  845. cdpCacheAddress.1.4 = "AC 14 01 01 "
  846. cdpCacheAddress.4.5 = "AC 14 12 03 "
  847. cdpCacheAddress.3.6 = "AC 14 12 01 "
  848. cdpCacheAddress.4.7 = "AC 14 1E 01 "
  849. cdpCacheAddress.4.8 = "AC 14 25 01 "
  850. cdpCacheAddress.4.9 = "AC 14 23 01 "
  851. cdpCacheAddress.4.10 = "AC 14 1E 02 "
  852. cdpCacheAddress.4.11 = "AC 14 16 01 "
  853. cdpCacheAddress.4.12 = "AC 14 25 01 "
  854. cdpCacheDeviceId.10.1 = CMP-SW2
  855. cdpCacheDeviceId.5.2 = Bundoora retirement Switch
  856. cdpCacheDeviceId.5.3 = HUM-SW1
  857. cdpCacheDeviceId.1.4 = CN-MEL-NAB-SW01.clearnw.net.au
  858. cdpCacheDeviceId.4.5 = CN11435 - NTU
  859. cdpCacheDeviceId.3.6 = CRG-SW1
  860. cdpCacheDeviceId.4.7 = GVL-SW1
  861. cdpCacheDeviceId.4.8 = ROM-SW1
  862. cdpCacheDeviceId.4.9 = BEV-SW1
  863. cdpCacheDeviceId.4.10 = GVL-SW2
  864. cdpCacheDeviceId.4.11 = WAL-SW1
  865. cdpCacheDeviceId.4.12 = ROM-SW1
  866.  
  867. Array
  868. (
  869.     [10] => Array
  870.         (
  871.             [1] => Array
  872.                 (
  873.                     [cdpCacheIfIndex] => 10
  874.                     [cdpCacheDeviceIndex] => 1
  875.                     [cdpCacheAddressType] => ip
  876.                     [cdpCacheAddress] => AC 14 11 02
  877.                     [cdpCacheDeviceId] => CMP-SW2
  878.                 )
  879.  
  880.         )
  881.  
  882.     [5] => Array
  883.         (
  884.             [2] => Array
  885.                 (
  886.                     [cdpCacheIfIndex] => 5
  887.                     [cdpCacheDeviceIndex] => 2
  888.                     [cdpCacheAddressType] => ip
  889.                     [cdpCacheAddress] => AC 10 09 03
  890.                     [cdpCacheDeviceId] => Bundoora retirement Switch
  891.                 )
  892.  
  893.             [3] => Array
  894.                 (
  895.                     [cdpCacheIfIndex] => 5
  896.                     [cdpCacheDeviceIndex] => 3
  897.                     [cdpCacheAddressType] => ip
  898.                     [cdpCacheAddress] => AC 14 15 01
  899.                     [cdpCacheDeviceId] => HUM-SW1
  900.                 )
  901.  
  902.         )
  903.  
  904.     [1] => Array
  905.         (
  906.             [4] => Array
  907.                 (
  908.                     [cdpCacheIfIndex] => 1
  909.                     [cdpCacheDeviceIndex] => 4
  910.                     [cdpCacheAddressType] => ip
  911.                     [cdpCacheAddress] => AC 14 01 01
  912.                     [cdpCacheDeviceId] => CN-MEL-NAB-SW01.clearnw.net.au
  913.                 )
  914.  
  915.         )
  916.  
  917.     [4] => Array
  918.         (
  919.             [5] => Array
  920.                 (
  921.                     [cdpCacheIfIndex] => 4
  922.                     [cdpCacheDeviceIndex] => 5
  923.                     [cdpCacheAddressType] => ip
  924.                     [cdpCacheAddress] => AC 14 12 03
  925.                     [cdpCacheDeviceId] => CN11435 - NTU
  926.                 )
  927.  
  928.             [7] => Array
  929.                 (
  930.                     [cdpCacheIfIndex] => 4
  931.                     [cdpCacheDeviceIndex] => 7
  932.                     [cdpCacheAddressType] => ip
  933.                     [cdpCacheAddress] => AC 14 1E 01
  934.                     [cdpCacheDeviceId] => GVL-SW1
  935.                 )
  936.  
  937.             [8] => Array
  938.                 (
  939.                     [cdpCacheIfIndex] => 4
  940.                     [cdpCacheDeviceIndex] => 8
  941.                     [cdpCacheAddressType] => ip
  942.                     [cdpCacheAddress] => AC 14 25 01
  943.                     [cdpCacheDeviceId] => ROM-SW1
  944.                 )
  945.  
  946.             [9] => Array
  947.                 (
  948.                     [cdpCacheIfIndex] => 4
  949.                     [cdpCacheDeviceIndex] => 9
  950.                     [cdpCacheAddressType] => ip
  951.                     [cdpCacheAddress] => AC 14 23 01
  952.                     [cdpCacheDeviceId] => BEV-SW1
  953.                 )
  954.  
  955.             [10] => Array
  956.                 (
  957.                     [cdpCacheIfIndex] => 4
  958.                     [cdpCacheDeviceIndex] => 10
  959.                     [cdpCacheAddressType] => ip
  960.                     [cdpCacheAddress] => AC 14 1E 02
  961.                     [cdpCacheDeviceId] => GVL-SW2
  962.                 )
  963.  
  964.             [11] => Array
  965.                 (
  966.                     [cdpCacheIfIndex] => 4
  967.                     [cdpCacheDeviceIndex] => 11
  968.                     [cdpCacheAddressType] => ip
  969.                     [cdpCacheAddress] => AC 14 16 01
  970.                     [cdpCacheDeviceId] => WAL-SW1
  971.                 )
  972.  
  973.             [12] => Array
  974.                 (
  975.                     [cdpCacheIfIndex] => 4
  976.                     [cdpCacheDeviceIndex] => 12
  977.                     [cdpCacheAddressType] => ip
  978.                     [cdpCacheAddress] => AC 14 25 01
  979.                     [cdpCacheDeviceId] => ROM-SW1
  980.                 )
  981.  
  982.         )
  983.  
  984.     [3] => Array
  985.         (
  986.             [6] => Array
  987.                 (
  988.                     [cdpCacheIfIndex] => 3
  989.                     [cdpCacheDeviceIndex] => 6
  990.                     [cdpCacheAddressType] => ip
  991.                     [cdpCacheAddress] => AC 14 12 01
  992.                     [cdpCacheDeviceId] => CRG-SW1
  993.                 )
  994.  
  995.         )
  996.  
  997. )
  998. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '10']
  999. Array
  1000. (
  1001.     [1] => Array
  1002.         (
  1003.             [cdpCacheIfIndex] => 10
  1004.             [cdpCacheDeviceIndex] => 1
  1005.             [cdpCacheAddressType] => ip
  1006.             [cdpCacheAddress] => AC 14 11 02
  1007.             [cdpCacheDeviceId] => CMP-SW2
  1008.         )
  1009.  
  1010. )
  1011. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'CMP-SW2' OR `hostname` = 'CMP-SW2' OR `hostname` = '172.20.17.2']
  1012. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '25']
  1013. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '5']
  1014. Array
  1015. (
  1016.     [2] => Array
  1017.         (
  1018.             [cdpCacheIfIndex] => 5
  1019.             [cdpCacheDeviceIndex] => 2
  1020.             [cdpCacheAddressType] => ip
  1021.             [cdpCacheAddress] => AC 10 09 03
  1022.             [cdpCacheDeviceId] => Bundoora retirement Switch
  1023.         )
  1024.  
  1025.     [3] => Array
  1026.         (
  1027.             [cdpCacheIfIndex] => 5
  1028.             [cdpCacheDeviceIndex] => 3
  1029.             [cdpCacheAddressType] => ip
  1030.             [cdpCacheAddress] => AC 14 15 01
  1031.             [cdpCacheDeviceId] => HUM-SW1
  1032.         )
  1033.  
  1034. )
  1035. XSQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'HUM-SW1' OR `hostname` = 'HUM-SW1' OR `hostname` = '172.20.21.1']
  1036. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '97']
  1037. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '1']
  1038. Array
  1039. (
  1040.     [4] => Array
  1041.         (
  1042.             [cdpCacheIfIndex] => 1
  1043.             [cdpCacheDeviceIndex] => 4
  1044.             [cdpCacheAddressType] => ip
  1045.             [cdpCacheAddress] => AC 14 01 01
  1046.             [cdpCacheDeviceId] => CN-MEL-NAB-SW01.clearnw.net.au
  1047.         )
  1048.  
  1049. )
  1050. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'CN-MEL-NAB-SW01.clearnw.net.au' OR `hostname` = 'CN-MEL-NAB-SW01.clearnw.net.au' OR `hostname` = '172.20.1.1']
  1051. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '37']
  1052. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '4']
  1053. Array
  1054. (
  1055.     [5] => Array
  1056.         (
  1057.             [cdpCacheIfIndex] => 4
  1058.             [cdpCacheDeviceIndex] => 5
  1059.             [cdpCacheAddressType] => ip
  1060.             [cdpCacheAddress] => AC 14 12 03
  1061.             [cdpCacheDeviceId] => CN11435 - NTU
  1062.         )
  1063.  
  1064.     [7] => Array
  1065.         (
  1066.             [cdpCacheIfIndex] => 4
  1067.             [cdpCacheDeviceIndex] => 7
  1068.             [cdpCacheAddressType] => ip
  1069.             [cdpCacheAddress] => AC 14 1E 01
  1070.             [cdpCacheDeviceId] => GVL-SW1
  1071.         )
  1072.  
  1073.     [8] => Array
  1074.         (
  1075.             [cdpCacheIfIndex] => 4
  1076.             [cdpCacheDeviceIndex] => 8
  1077.             [cdpCacheAddressType] => ip
  1078.             [cdpCacheAddress] => AC 14 25 01
  1079.             [cdpCacheDeviceId] => ROM-SW1
  1080.         )
  1081.  
  1082.     [9] => Array
  1083.         (
  1084.             [cdpCacheIfIndex] => 4
  1085.             [cdpCacheDeviceIndex] => 9
  1086.             [cdpCacheAddressType] => ip
  1087.             [cdpCacheAddress] => AC 14 23 01
  1088.             [cdpCacheDeviceId] => BEV-SW1
  1089.         )
  1090.  
  1091.     [10] => Array
  1092.         (
  1093.             [cdpCacheIfIndex] => 4
  1094.             [cdpCacheDeviceIndex] => 10
  1095.             [cdpCacheAddressType] => ip
  1096.             [cdpCacheAddress] => AC 14 1E 02
  1097.             [cdpCacheDeviceId] => GVL-SW2
  1098.         )
  1099.  
  1100.     [11] => Array
  1101.         (
  1102.             [cdpCacheIfIndex] => 4
  1103.             [cdpCacheDeviceIndex] => 11
  1104.             [cdpCacheAddressType] => ip
  1105.             [cdpCacheAddress] => AC 14 16 01
  1106.             [cdpCacheDeviceId] => WAL-SW1
  1107.         )
  1108.  
  1109.     [12] => Array
  1110.         (
  1111.             [cdpCacheIfIndex] => 4
  1112.             [cdpCacheDeviceIndex] => 12
  1113.             [cdpCacheAddressType] => ip
  1114.             [cdpCacheAddress] => AC 14 25 01
  1115.             [cdpCacheDeviceId] => ROM-SW1
  1116.         )
  1117.  
  1118. )
  1119. XSQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'GVL-SW1' OR `hostname` = 'GVL-SW1' OR `hostname` = '172.20.30.1']
  1120. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '105']
  1121. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'ROM-SW1' OR `hostname` = 'ROM-SW1' OR `hostname` = '172.20.37.1']
  1122. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '111']
  1123. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'BEV-SW1' OR `hostname` = 'BEV-SW1' OR `hostname` = '172.20.35.1']
  1124. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '110']
  1125. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'GVL-SW2' OR `hostname` = 'GVL-SW2' OR `hostname` = '172.20.30.2']
  1126. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '104']
  1127. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'WAL-SW1' OR `hostname` = 'WAL-SW1' OR `hostname` = '172.20.22.1']
  1128. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '98']
  1129. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'ROM-SW1' OR `hostname` = 'ROM-SW1' OR `hostname` = '172.20.37.1']
  1130. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '111']
  1131. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '3']
  1132. Array
  1133. (
  1134.     [6] => Array
  1135.         (
  1136.             [cdpCacheIfIndex] => 3
  1137.             [cdpCacheDeviceIndex] => 6
  1138.             [cdpCacheAddressType] => ip
  1139.             [cdpCacheAddress] => AC 14 12 01
  1140.             [cdpCacheDeviceId] => CRG-SW1
  1141.         )
  1142.  
  1143. )
  1144. SQL[SELECT `device_id` FROM `devices` WHERE `sysName` = 'CRG-SW1' OR `hostname` = 'CRG-SW1' OR `hostname` = '172.20.18.1']
  1145. SQL[SELECT port_id FROM `ports` WHERE (`ifDescr` = '' OR `ifName` = '') AND `device_id` = '92']
  1146.  LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 lldpRemoteSystemsData]
  1147. lldpRemoteSystemsData = No Such Object available on this agent at this OID
  1148.  
  1149. lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData ||  ||  ||
  1150. Array
  1151. (
  1152. )
  1153. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dBasePortIfIndex]
  1154. dot1dBasePortIfIndex.1 = 1
  1155. dot1dBasePortIfIndex.2 = 2
  1156. dot1dBasePortIfIndex.3 = 3
  1157. dot1dBasePortIfIndex.4 = 4
  1158. dot1dBasePortIfIndex.5 = 5
  1159. dot1dBasePortIfIndex.6 = 6
  1160. dot1dBasePortIfIndex.7 = 7
  1161. dot1dBasePortIfIndex.8 = 8
  1162. dot1dBasePortIfIndex.9 = 9
  1163. dot1dBasePortIfIndex.10 = 10
  1164. dot1dBasePortIfIndex.11 = 11
  1165. dot1dBasePortIfIndex.12 = 12
  1166. dot1dBasePortIfIndex.13 = 13
  1167. dot1dBasePortIfIndex.14 = 14
  1168.  
  1169. Array
  1170. (
  1171.     [1] => Array
  1172.         (
  1173.             [dot1dBasePortIfIndex] => 1
  1174.         )
  1175.  
  1176.     [2] => Array
  1177.         (
  1178.             [dot1dBasePortIfIndex] => 2
  1179.         )
  1180.  
  1181.     [3] => Array
  1182.         (
  1183.             [dot1dBasePortIfIndex] => 3
  1184.         )
  1185.  
  1186.     [4] => Array
  1187.         (
  1188.             [dot1dBasePortIfIndex] => 4
  1189.         )
  1190.  
  1191.     [5] => Array
  1192.         (
  1193.             [dot1dBasePortIfIndex] => 5
  1194.         )
  1195.  
  1196.     [6] => Array
  1197.         (
  1198.             [dot1dBasePortIfIndex] => 6
  1199.         )
  1200.  
  1201.     [7] => Array
  1202.         (
  1203.             [dot1dBasePortIfIndex] => 7
  1204.         )
  1205.  
  1206.     [8] => Array
  1207.         (
  1208.             [dot1dBasePortIfIndex] => 8
  1209.         )
  1210.  
  1211.     [9] => Array
  1212.         (
  1213.             [dot1dBasePortIfIndex] => 9
  1214.         )
  1215.  
  1216.     [10] => Array
  1217.         (
  1218.             [dot1dBasePortIfIndex] => 10
  1219.         )
  1220.  
  1221.     [11] => Array
  1222.         (
  1223.             [dot1dBasePortIfIndex] => 11
  1224.         )
  1225.  
  1226.     [12] => Array
  1227.         (
  1228.             [dot1dBasePortIfIndex] => 12
  1229.         )
  1230.  
  1231.     [13] => Array
  1232.         (
  1233.             [dot1dBasePortIfIndex] => 13
  1234.         )
  1235.  
  1236.     [14] => Array
  1237.         (
  1238.             [dot1dBasePortIfIndex] => 14
  1239.         )
  1240.  
  1241. )
  1242.  OSPF Discovery: enabled
  1243. SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='25']
  1244. SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '25']
  1245.  
  1246.  
  1247. >> Runtime for discovery module 'discovery-protocols': 0.1510 seconds with 36480 bytes
  1248. #### Unload disco module discovery-protocols ####
  1249.  
  1250. Modules status: Global+ OS  Device  
  1251. #### Load disco module arp-table ####
  1252. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
  1253. ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  1254.  
  1255. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 ipNetToMediaPhysAddress]
  1256. ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
  1257.  
  1258. SQL[SELECT * from `ipv4_mac` WHERE `device_id`='25' AND `context_name`='']
  1259. SQL[DELETE `ipv4_mac` FROM `ipv4_mac`
  1260.  LEFT JOIN `ports` ON `ipv4_mac`.`port_id` = `ports`.`port_id`
  1261.  LEFT JOIN `devices` ON `ipv4_mac`.`device_id` = `devices`.`device_id`
  1262.  WHERE `ports`.`port_id` IS NULL OR `devices`.`device_id` IS NULL]
  1263.  
  1264.  
  1265. >> Runtime for discovery module 'arp-table': 0.0630 seconds with -12536 bytes
  1266. #### Unload disco module arp-table ####
  1267.  
  1268. Modules status: Global- OS  Device  Module [ discovery-arp ] disabled globally.
  1269.  
  1270. Modules status: Global- OS  Device  Module [ junose-atm-vp ] disabled globally.
  1271.  
  1272. Modules status: Global+ OS  Device  
  1273. #### Load disco module bgp-peers ####
  1274. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 .1.3.6.1.2.1.15.2]
  1275. No Such Object available on this agent at this OID
  1276.  
  1277. No BGP on hostPeers :
  1278. SQL[SELECT * FROM bgpPeers WHERE device_id = '25' AND (context_name = '' OR context_name IS NULL)]
  1279.  
  1280.  
  1281. >> Runtime for discovery module 'bgp-peers': 0.0510 seconds with 2648 bytes
  1282. #### Unload disco module bgp-peers ####
  1283.  
  1284. Modules status: Global+ OS  Device  
  1285. #### Load disco module vlans ####
  1286. SQL[SELECT * FROM `vlans` WHERE `device_id` = '25']
  1287. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dBasePortIfIndex]
  1288. dot1dBasePortIfIndex.1 = 1
  1289. dot1dBasePortIfIndex.2 = 2
  1290. dot1dBasePortIfIndex.3 = 3
  1291. dot1dBasePortIfIndex.4 = 4
  1292. dot1dBasePortIfIndex.5 = 5
  1293. dot1dBasePortIfIndex.6 = 6
  1294. dot1dBasePortIfIndex.7 = 7
  1295. dot1dBasePortIfIndex.8 = 8
  1296. dot1dBasePortIfIndex.9 = 9
  1297. dot1dBasePortIfIndex.10 = 10
  1298. dot1dBasePortIfIndex.11 = 11
  1299. dot1dBasePortIfIndex.12 = 12
  1300. dot1dBasePortIfIndex.13 = 13
  1301. dot1dBasePortIfIndex.14 = 14
  1302.  
  1303.  
  1304. >> Runtime for discovery module 'vlans': 0.0240 seconds with 2784 bytes
  1305. #### Unload disco module vlans ####
  1306.  
  1307. Modules status: Global- OS  Device  Module [ vmware-vminfo ] disabled globally.
  1308.  
  1309. Modules status: Global- OS  Device  Module [ libvirt-vminfo ] disabled globally.
  1310.  
  1311. Modules status: Global- OS  Device  Module [ toner ] disabled globally.
  1312.  
  1313. Modules status: Global+ OS  Device  
  1314. #### Load disco module ucd-diskio ####
  1315. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 diskIOEntry]
  1316. diskIOEntry = No Such Object available on this agent at this OID
  1317.  
  1318. Array
  1319. (
  1320. )
  1321. SQL[SELECT * FROM `ucd_diskio` where `device_id`  = '25']
  1322.  
  1323.  
  1324. >> Runtime for discovery module 'ucd-diskio': 0.0260 seconds with 736 bytes
  1325. #### Unload disco module ucd-diskio ####
  1326.  
  1327. Modules status: Global- OS  Device  Module [ applications ] disabled globally.
  1328.  
  1329. Modules status: Global+ OS  Device  
  1330. #### Load disco module services ####
  1331.  
  1332. >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
  1333. #### Unload disco module services ####
  1334.  
  1335. Modules status: Global+ OS  Device  
  1336. #### Load disco module stp ####
  1337. SQL[SELECT * FROM `stp` WHERE `device_id` = '25']
  1338. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
  1339. ieee8021d
  1340.  
  1341. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dStp]
  1342. dot1dStpProtocolSpecification.0 = ieee8021d
  1343. dot1dStpPriority.0 = 32768
  1344. dot1dStpTimeSinceTopologyChange.0 = 2147483647
  1345. dot1dStpTopChanges.0 = 0
  1346. dot1dStpDesignatedRoot.0 = "80 00 EC 13 B2 81 96 2C "
  1347. dot1dStpRootCost.0 = 0
  1348. dot1dStpRootPort.0 = 65535
  1349. dot1dStpMaxAge.0 = 20
  1350. dot1dStpHelloTime.0 = 2
  1351. dot1dStpHoldTime.0 = 6
  1352. dot1dStpForwardDelay.0 = 15
  1353. dot1dStpBridgeMaxAge.0 = 20
  1354. dot1dStpBridgeHelloTime.0 = 2
  1355. dot1dStpBridgeForwardDelay.0 = 15
  1356. dot1dStpPort.1 = 1
  1357. dot1dStpPort.2 = 2
  1358. dot1dStpPort.3 = 3
  1359. dot1dStpPort.4 = 4
  1360. dot1dStpPort.5 = 5
  1361. dot1dStpPort.6 = 6
  1362. dot1dStpPort.7 = 7
  1363. dot1dStpPort.8 = 8
  1364. dot1dStpPort.9 = 9
  1365. dot1dStpPort.10 = 10
  1366. dot1dStpPort.11 = 11
  1367. dot1dStpPort.12 = 12
  1368. dot1dStpPort.13 = 13
  1369. dot1dStpPort.14 = 14
  1370. dot1dStpPortPriority.1 = 128
  1371. dot1dStpPortPriority.2 = 128
  1372. dot1dStpPortPriority.3 = 128
  1373. dot1dStpPortPriority.4 = 128
  1374. dot1dStpPortPriority.5 = 128
  1375. dot1dStpPortPriority.6 = 128
  1376. dot1dStpPortPriority.7 = 128
  1377. dot1dStpPortPriority.8 = 128
  1378. dot1dStpPortPriority.9 = 128
  1379. dot1dStpPortPriority.10 = 128
  1380. dot1dStpPortPriority.11 = 128
  1381. dot1dStpPortPriority.12 = 128
  1382. dot1dStpPortPriority.13 = 128
  1383. dot1dStpPortPriority.14 = 128
  1384. dot1dStpPortState.1 = forwarding
  1385. dot1dStpPortState.2 = forwarding
  1386. dot1dStpPortState.3 = forwarding
  1387. dot1dStpPortState.4 = forwarding
  1388. dot1dStpPortState.5 = forwarding
  1389. dot1dStpPortState.6 = forwarding
  1390. dot1dStpPortState.7 = forwarding
  1391. dot1dStpPortState.8 = forwarding
  1392. dot1dStpPortState.9 = forwarding
  1393. dot1dStpPortState.10 = forwarding
  1394. dot1dStpPortState.11 = forwarding
  1395. dot1dStpPortState.12 = forwarding
  1396. dot1dStpPortState.13 = forwarding
  1397. dot1dStpPortState.14 = forwarding
  1398. dot1dStpPortEnable.1 = enabled
  1399. dot1dStpPortEnable.2 = enabled
  1400. dot1dStpPortEnable.3 = enabled
  1401. dot1dStpPortEnable.4 = enabled
  1402. dot1dStpPortEnable.5 = enabled
  1403. dot1dStpPortEnable.6 = enabled
  1404. dot1dStpPortEnable.7 = enabled
  1405. dot1dStpPortEnable.8 = enabled
  1406. dot1dStpPortEnable.9 = enabled
  1407. dot1dStpPortEnable.10 = enabled
  1408. dot1dStpPortEnable.11 = enabled
  1409. dot1dStpPortEnable.12 = enabled
  1410. dot1dStpPortEnable.13 = enabled
  1411. dot1dStpPortEnable.14 = enabled
  1412. dot1dStpPortDesignatedRoot.1 = "00 00 00 00 00 00 00 00 "
  1413. dot1dStpPortDesignatedRoot.2 = "00 00 00 00 00 00 00 00 "
  1414. dot1dStpPortDesignatedRoot.3 = "00 00 00 00 00 00 00 00 "
  1415. dot1dStpPortDesignatedRoot.4 = "00 00 00 00 00 00 00 00 "
  1416. dot1dStpPortDesignatedRoot.5 = "00 00 00 00 00 00 00 00 "
  1417. dot1dStpPortDesignatedRoot.6 = "00 00 00 00 00 00 00 00 "
  1418. dot1dStpPortDesignatedRoot.7 = "00 00 00 00 00 00 00 00 "
  1419. dot1dStpPortDesignatedRoot.8 = "00 00 00 00 00 00 00 00 "
  1420. dot1dStpPortDesignatedRoot.9 = "00 00 00 00 00 00 00 00 "
  1421. dot1dStpPortDesignatedRoot.10 = "00 00 00 00 00 00 00 00 "
  1422. dot1dStpPortDesignatedRoot.11 = "00 00 00 00 00 00 00 00 "
  1423. dot1dStpPortDesignatedRoot.12 = "00 00 00 00 00 00 00 00 "
  1424. dot1dStpPortDesignatedRoot.13 = "00 00 00 00 00 00 00 00 "
  1425. dot1dStpPortDesignatedRoot.14 = "00 00 00 00 00 00 00 00 "
  1426. dot1dStpPortDesignatedCost.1 = 0
  1427. dot1dStpPortDesignatedCost.2 = 0
  1428. dot1dStpPortDesignatedCost.3 = 0
  1429. dot1dStpPortDesignatedCost.4 = 0
  1430. dot1dStpPortDesignatedCost.5 = 0
  1431. dot1dStpPortDesignatedCost.6 = 0
  1432. dot1dStpPortDesignatedCost.7 = 0
  1433. dot1dStpPortDesignatedCost.8 = 0
  1434. dot1dStpPortDesignatedCost.9 = 0
  1435. dot1dStpPortDesignatedCost.10 = 0
  1436. dot1dStpPortDesignatedCost.11 = 0
  1437. dot1dStpPortDesignatedCost.12 = 0
  1438. dot1dStpPortDesignatedCost.13 = 0
  1439. dot1dStpPortDesignatedCost.14 = 0
  1440. dot1dStpPortDesignatedBridge.1 = "00 00 00 00 00 00 00 00 "
  1441. dot1dStpPortDesignatedBridge.2 = "00 00 00 00 00 00 00 00 "
  1442. dot1dStpPortDesignatedBridge.3 = "00 00 00 00 00 00 00 00 "
  1443. dot1dStpPortDesignatedBridge.4 = "00 00 00 00 00 00 00 00 "
  1444. dot1dStpPortDesignatedBridge.5 = "00 00 00 00 00 00 00 00 "
  1445. dot1dStpPortDesignatedBridge.6 = "00 00 00 00 00 00 00 00 "
  1446. dot1dStpPortDesignatedBridge.7 = "00 00 00 00 00 00 00 00 "
  1447. dot1dStpPortDesignatedBridge.8 = "00 00 00 00 00 00 00 00 "
  1448. dot1dStpPortDesignatedBridge.9 = "00 00 00 00 00 00 00 00 "
  1449. dot1dStpPortDesignatedBridge.10 = "00 00 00 00 00 00 00 00 "
  1450. dot1dStpPortDesignatedBridge.11 = "00 00 00 00 00 00 00 00 "
  1451. dot1dStpPortDesignatedBridge.12 = "00 00 00 00 00 00 00 00 "
  1452. dot1dStpPortDesignatedBridge.13 = "00 00 00 00 00 00 00 00 "
  1453. dot1dStpPortDesignatedBridge.14 = "00 00 00 00 00 00 00 00 "
  1454. dot1dStpPortDesignatedPort.1 = "00 00 "
  1455. dot1dStpPortDesignatedPort.2 = "00 00 "
  1456. dot1dStpPortDesignatedPort.3 = "00 00 "
  1457. dot1dStpPortDesignatedPort.4 = "00 00 "
  1458. dot1dStpPortDesignatedPort.5 = "00 00 "
  1459. dot1dStpPortDesignatedPort.6 = "00 00 "
  1460. dot1dStpPortDesignatedPort.7 = "00 00 "
  1461. dot1dStpPortDesignatedPort.8 = "00 00 "
  1462. dot1dStpPortDesignatedPort.9 = "00 00 "
  1463. dot1dStpPortDesignatedPort.10 = "00 00 "
  1464. dot1dStpPortDesignatedPort.11 = "00 00 "
  1465. dot1dStpPortDesignatedPort.12 = "00 00 "
  1466. dot1dStpPortDesignatedPort.13 = "00 00 "
  1467. dot1dStpPortDesignatedPort.14 = "00 00 "
  1468. dot1dStpPortPathCost32.1 = 0
  1469. dot1dStpPortPathCost32.2 = 0
  1470. dot1dStpPortPathCost32.3 = 0
  1471. dot1dStpPortPathCost32.4 = 0
  1472. dot1dStpPortPathCost32.5 = 0
  1473. dot1dStpPortPathCost32.6 = 0
  1474. dot1dStpPortPathCost32.7 = 0
  1475. dot1dStpPortPathCost32.8 = 0
  1476. dot1dStpPortPathCost32.9 = 0
  1477. dot1dStpPortPathCost32.10 = 0
  1478. dot1dStpPortPathCost32.11 = 0
  1479. dot1dStpPortPathCost32.12 = 0
  1480. dot1dStpPortPathCost32.13 = 0
  1481. dot1dStpPortPathCost32.14 = 0
  1482. dot1dStpVersion.0 = rstp
  1483. dot1dStpTxHoldCount.0 = 6
  1484.  
  1485. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dBaseBridgeAddress.0]
  1486. ec:13:b2:81:96:2c
  1487.  
  1488. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovt -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dStpTimeSinceTopologyChange.0]
  1489. Wrong Type (should be Timeticks): Counter32: 2147483647
  1490.  
  1491. Array
  1492. (
  1493.     [protocolSpecification] => ieee8021d
  1494.     [priority] => 32768
  1495.     [topChanges] => 0
  1496.     [rootCost] => 0
  1497.     [rootPort] => 65535
  1498.     [maxAge] => 0.2
  1499.     [helloTime] => 0.02
  1500.     [holdTime] => 0.06
  1501.     [forwardDelay] => 0.15
  1502.     [bridgeMaxAge] => 0.2
  1503.     [bridgeHelloTime] => 0.02
  1504.     [bridgeForwardDelay] => 0.15
  1505.     [device_id] => 25
  1506.     [timeSinceTopologyChange] => Wrong Type (should be Timeticks): Counter32: 21474836
  1507.     [designatedRoot] => ec13b281962c
  1508.     [bridgeAddress] => ec13b281962c
  1509.     [rootBridge] => 1
  1510. )
  1511. STP SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '1']
  1512. Array
  1513. (
  1514.     [priority] => 128
  1515.     [state] => forwarding
  1516.     [enable] => enabled
  1517.     [pathCost] =>
  1518.     [designatedCost] => 0
  1519.     [designatedPort] => 0
  1520.     [forwardTransitions] =>
  1521.     [device_id] => 25
  1522.     [port_id] => 111
  1523.     [designatedRoot] => 000000000000
  1524.     [designatedBridge] => 000000000000
  1525. )
  1526. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '111']
  1527. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '2']
  1528. Array
  1529. (
  1530.     [priority] => 128
  1531.     [state] => forwarding
  1532.     [enable] => enabled
  1533.     [pathCost] =>
  1534.     [designatedCost] => 0
  1535.     [designatedPort] => 0
  1536.     [forwardTransitions] =>
  1537.     [device_id] => 25
  1538.     [port_id] => 112
  1539.     [designatedRoot] => 000000000000
  1540.     [designatedBridge] => 000000000000
  1541. )
  1542. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '112']
  1543. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '3']
  1544. Array
  1545. (
  1546.     [priority] => 128
  1547.     [state] => forwarding
  1548.     [enable] => enabled
  1549.     [pathCost] =>
  1550.     [designatedCost] => 0
  1551.     [designatedPort] => 0
  1552.     [forwardTransitions] =>
  1553.     [device_id] => 25
  1554.     [port_id] => 113
  1555.     [designatedRoot] => 000000000000
  1556.     [designatedBridge] => 000000000000
  1557. )
  1558. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '113']
  1559. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '4']
  1560. Array
  1561. (
  1562.     [priority] => 128
  1563.     [state] => forwarding
  1564.     [enable] => enabled
  1565.     [pathCost] =>
  1566.     [designatedCost] => 0
  1567.     [designatedPort] => 0
  1568.     [forwardTransitions] =>
  1569.     [device_id] => 25
  1570.     [port_id] => 114
  1571.     [designatedRoot] => 000000000000
  1572.     [designatedBridge] => 000000000000
  1573. )
  1574. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '114']
  1575. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '5']
  1576. Array
  1577. (
  1578.     [priority] => 128
  1579.     [state] => forwarding
  1580.     [enable] => enabled
  1581.     [pathCost] =>
  1582.     [designatedCost] => 0
  1583.     [designatedPort] => 0
  1584.     [forwardTransitions] =>
  1585.     [device_id] => 25
  1586.     [port_id] => 115
  1587.     [designatedRoot] => 000000000000
  1588.     [designatedBridge] => 000000000000
  1589. )
  1590. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '115']
  1591. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '6']
  1592. Array
  1593. (
  1594.     [priority] => 128
  1595.     [state] => forwarding
  1596.     [enable] => enabled
  1597.     [pathCost] =>
  1598.     [designatedCost] => 0
  1599.     [designatedPort] => 0
  1600.     [forwardTransitions] =>
  1601.     [device_id] => 25
  1602.     [port_id] => 116
  1603.     [designatedRoot] => 000000000000
  1604.     [designatedBridge] => 000000000000
  1605. )
  1606. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '116']
  1607. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '7']
  1608. Array
  1609. (
  1610.     [priority] => 128
  1611.     [state] => forwarding
  1612.     [enable] => enabled
  1613.     [pathCost] =>
  1614.     [designatedCost] => 0
  1615.     [designatedPort] => 0
  1616.     [forwardTransitions] =>
  1617.     [device_id] => 25
  1618.     [port_id] => 117
  1619.     [designatedRoot] => 000000000000
  1620.     [designatedBridge] => 000000000000
  1621. )
  1622. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '117']
  1623. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '8']
  1624. Array
  1625. (
  1626.     [priority] => 128
  1627.     [state] => forwarding
  1628.     [enable] => enabled
  1629.     [pathCost] =>
  1630.     [designatedCost] => 0
  1631.     [designatedPort] => 0
  1632.     [forwardTransitions] =>
  1633.     [device_id] => 25
  1634.     [port_id] => 118
  1635.     [designatedRoot] => 000000000000
  1636.     [designatedBridge] => 000000000000
  1637. )
  1638. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '118']
  1639. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '9']
  1640. Array
  1641. (
  1642.     [priority] => 128
  1643.     [state] => forwarding
  1644.     [enable] => enabled
  1645.     [pathCost] =>
  1646.     [designatedCost] => 0
  1647.     [designatedPort] => 0
  1648.     [forwardTransitions] =>
  1649.     [device_id] => 25
  1650.     [port_id] => 119
  1651.     [designatedRoot] => 000000000000
  1652.     [designatedBridge] => 000000000000
  1653. )
  1654. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '119']
  1655. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '10']
  1656. Array
  1657. (
  1658.     [priority] => 128
  1659.     [state] => forwarding
  1660.     [enable] => enabled
  1661.     [pathCost] =>
  1662.     [designatedCost] => 0
  1663.     [designatedPort] => 0
  1664.     [forwardTransitions] =>
  1665.     [device_id] => 25
  1666.     [port_id] => 120
  1667.     [designatedRoot] => 000000000000
  1668.     [designatedBridge] => 000000000000
  1669. )
  1670. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '120']
  1671. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '11']
  1672. Array
  1673. (
  1674.     [priority] => 128
  1675.     [state] => forwarding
  1676.     [enable] => enabled
  1677.     [pathCost] =>
  1678.     [designatedCost] => 0
  1679.     [designatedPort] => 0
  1680.     [forwardTransitions] =>
  1681.     [device_id] => 25
  1682.     [port_id] => 121
  1683.     [designatedRoot] => 000000000000
  1684.     [designatedBridge] => 000000000000
  1685. )
  1686. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '121']
  1687. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '12']
  1688. Array
  1689. (
  1690.     [priority] => 128
  1691.     [state] => forwarding
  1692.     [enable] => enabled
  1693.     [pathCost] =>
  1694.     [designatedCost] => 0
  1695.     [designatedPort] => 0
  1696.     [forwardTransitions] =>
  1697.     [device_id] => 25
  1698.     [port_id] => 122
  1699.     [designatedRoot] => 000000000000
  1700.     [designatedBridge] => 000000000000
  1701. )
  1702. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '122']
  1703. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '13']
  1704. Array
  1705. (
  1706.     [priority] => 128
  1707.     [state] => forwarding
  1708.     [enable] => enabled
  1709.     [pathCost] =>
  1710.     [designatedCost] => 0
  1711.     [designatedPort] => 0
  1712.     [forwardTransitions] =>
  1713.     [device_id] => 25
  1714.     [port_id] => 123
  1715.     [designatedRoot] => 000000000000
  1716.     [designatedBridge] => 000000000000
  1717. )
  1718. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '123']
  1719. SQL[SELECT port_id FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '14']
  1720. Array
  1721. (
  1722.     [priority] => 128
  1723.     [state] => forwarding
  1724.     [enable] => enabled
  1725.     [pathCost] =>
  1726.     [designatedCost] => 0
  1727.     [designatedPort] => 0
  1728.     [forwardTransitions] =>
  1729.     [device_id] => 25
  1730.     [port_id] => 124
  1731.     [designatedRoot] => 000000000000
  1732.     [designatedBridge] => 000000000000
  1733. )
  1734. SQL[SELECT 1 FROM `ports_stp` WHERE `device_id` = '25' AND `port_id` = '124']
  1735. SQL[SELECT * FROM `ports_stp` WHERE `device_id` = '25']
  1736. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '111']
  1737. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '112']
  1738. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '113']
  1739. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '114']
  1740. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '115']
  1741. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '116']
  1742. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '117']
  1743. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '118']
  1744. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '119']
  1745. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '120']
  1746. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '121']
  1747. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '122']
  1748. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '123']
  1749. SQL[SELECT `ifIndex` FROM `ports` WHERE `device_id` = '25' AND `port_id` = '124']
  1750.  
  1751.  
  1752. >> Runtime for discovery module 'stp': 0.1790 seconds with 6472 bytes
  1753. #### Unload disco module stp ####
  1754.  
  1755. Modules status: Global+ OS  Device  
  1756. #### Load disco module ntp ####
  1757.  
  1758. >> Runtime for discovery module 'ntp': 6.6040 seconds with 144 bytes
  1759. #### Unload disco module ntp ####
  1760.  
  1761. Modules status: Global- OS  Device  Module [ loadbalancers ] disabled globally.
  1762.  
  1763. Modules status: Global- OS  Device  Module [ mef ] disabled globally.
  1764.  
  1765. Modules status: Global+ OS  Device  
  1766. #### Load disco module wireless ####
  1767. Attempting to initialize OS: netonix
  1768. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='ap-count']
  1769. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='clients']
  1770. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='quality']
  1771. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='capacity']
  1772. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='utilization']
  1773. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='rate']
  1774. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='ccq']
  1775. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='snr']
  1776. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='mse']
  1777. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='rssi']
  1778. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='power']
  1779. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='noise-floor']
  1780. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='error-ratio']
  1781. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='error-rate']
  1782. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='frequency']
  1783. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='25' AND `sensor_class`='distance']
  1784.  
  1785. >> Runtime for discovery module 'wireless': 0.0050 seconds with 132776 bytes
  1786. #### Unload disco module wireless ####
  1787.  
  1788. Modules status: Global+ OS  Device  
  1789. #### Load disco module fdb-table ####
  1790. SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '25']
  1791. SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = '25']
  1792. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1qTpFdbPort]
  1793. dot1qTpFdbPort = No Such Object available on this agent at this OID
  1794.  
  1795. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dTpFdbPort]
  1796. dot1dTpFdbPort[.1 = 0
  1797. dot1dTpFdbPort[.2 = 1
  1798. dot1dTpFdbPort[.3 = 1
  1799. dot1dTpFdbPort[.4 = 4
  1800. dot1dTpFdbPort[.5 = 4
  1801. dot1dTpFdbPort[.6 = 4
  1802. dot1dTpFdbPort[.7 = 4
  1803. dot1dTpFdbPort[.8 = 4
  1804. dot1dTpFdbPort[.9 = 3
  1805. dot1dTpFdbPort[.10 = 4
  1806. dot1dTpFdbPort[.11 = 3
  1807. dot1dTpFdbPort[.12 = 1
  1808. dot1dTpFdbPort[.13 = 1
  1809. dot1dTpFdbPort[.14 = 1
  1810. dot1dTpFdbPort[.15 = 3
  1811. dot1dTpFdbPort[.16 = 4
  1812. dot1dTpFdbPort[.17 = 4
  1813. dot1dTpFdbPort[.18 = 4
  1814. dot1dTpFdbPort[.19 = 4
  1815. dot1dTpFdbPort[.20 = 3
  1816. dot1dTpFdbPort[.21 = 4
  1817. dot1dTpFdbPort[.22 = 1
  1818. dot1dTpFdbPort[.23 = 1
  1819. dot1dTpFdbPort[.24 = 4
  1820. dot1dTpFdbPort[.25 = 4
  1821. dot1dTpFdbPort[.26 = 1
  1822. dot1dTpFdbPort[.27 = 1
  1823. dot1dTpFdbPort[.28 = 1
  1824. dot1dTpFdbPort[.29 = 4
  1825. dot1dTpFdbPort[.30 = 1
  1826. dot1dTpFdbPort[.31 = 1
  1827. dot1dTpFdbPort[.32 = 1
  1828. dot1dTpFdbPort[.33 = 1
  1829. dot1dTpFdbPort[.34 = 1
  1830. dot1dTpFdbPort[.35 = 1
  1831. dot1dTpFdbPort[.36 = 4
  1832. dot1dTpFdbPort[.37 = 9
  1833. dot1dTpFdbPort[.38 = 7
  1834. dot1dTpFdbPort[.39 = 8
  1835. dot1dTpFdbPort[.40 = 1
  1836. dot1dTpFdbPort[.41 = 1
  1837. dot1dTpFdbPort[.42 = 1
  1838. dot1dTpFdbPort[.43 = 1
  1839. dot1dTpFdbPort[.44 = 1
  1840. dot1dTpFdbPort[.45 = 1
  1841. dot1dTpFdbPort[.46 = 1
  1842. dot1dTpFdbPort[.47 = 1
  1843. dot1dTpFdbPort[.48 = 1
  1844. dot1dTpFdbPort[.49 = 1
  1845. dot1dTpFdbPort[.50 = 1
  1846. dot1dTpFdbPort[.51 = 1
  1847. dot1dTpFdbPort[.52 = 1
  1848. dot1dTpFdbPort[.53 = 4
  1849. dot1dTpFdbPort[.54 = 1
  1850. dot1dTpFdbPort[.55 = 1
  1851. dot1dTpFdbPort[.56 = 4
  1852. dot1dTpFdbPort[.57 = 1
  1853. dot1dTpFdbPort[.58 = 4
  1854. dot1dTpFdbPort[.59 = 1
  1855. dot1dTpFdbPort[.60 = 1
  1856. dot1dTpFdbPort[.61 = 1
  1857. dot1dTpFdbPort[.62 = 1
  1858. dot1dTpFdbPort[.63 = 1
  1859. dot1dTpFdbPort[.64 = 1
  1860. dot1dTpFdbPort[.65 = 1
  1861. dot1dTpFdbPort[.66 = 1
  1862. dot1dTpFdbPort[.67 = 1
  1863. dot1dTpFdbPort[.68 = 1
  1864. dot1dTpFdbPort[.69 = 1
  1865. dot1dTpFdbPort[.70 = 1
  1866. dot1dTpFdbPort[.71 = 3
  1867. dot1dTpFdbPort[.72 = 4
  1868. dot1dTpFdbPort[.73 = 1
  1869. dot1dTpFdbPort[.74 = 4
  1870. dot1dTpFdbPort[.75 = 4
  1871. dot1dTpFdbPort[.76 = 5
  1872. dot1dTpFdbPort[.77 = 3
  1873. dot1dTpFdbPort[.78 = 1
  1874. dot1dTpFdbPort[.79 = 4
  1875. dot1dTpFdbPort[.80 = 3
  1876. dot1dTpFdbPort[.81 = 4
  1877. dot1dTpFdbPort[.82 = 4
  1878. dot1dTpFdbPort[.83 = 9
  1879. dot1dTpFdbPort[.84 = 3
  1880. dot1dTpFdbPort[.85 = 1
  1881. dot1dTpFdbPort[.86 = 1
  1882. dot1dTpFdbPort[.87 = 1
  1883. dot1dTpFdbPort[.88 = 3
  1884. dot1dTpFdbPort[.89 = 1
  1885. dot1dTpFdbPort[.90 = 9
  1886. dot1dTpFdbPort[.91 = 1
  1887. dot1dTpFdbPort[.92 = 4
  1888. dot1dTpFdbPort[.93 = 4
  1889. dot1dTpFdbPort[.94 = 1
  1890. dot1dTpFdbPort[.95 = 1
  1891. dot1dTpFdbPort[.96 = 1
  1892. dot1dTpFdbPort[.97 = 4
  1893. dot1dTpFdbPort[.98 = 1
  1894. dot1dTpFdbPort[.99 = 1
  1895. dot1dTpFdbPort[.100 = 1
  1896. dot1dTpFdbPort[.101 = 4
  1897. dot1dTpFdbPort[.102 = 1
  1898. dot1dTpFdbPort[.103 = 5
  1899. dot1dTpFdbPort[.104 = 3
  1900. dot1dTpFdbPort[.105 = 1
  1901. dot1dTpFdbPort[.106 = 1
  1902. dot1dTpFdbPort[.107 = 1
  1903. dot1dTpFdbPort[.108 = 1
  1904. dot1dTpFdbPort[.109 = 1
  1905. dot1dTpFdbPort[.110 = 1
  1906. dot1dTpFdbPort[.111 = 1
  1907. dot1dTpFdbPort[.112 = 1
  1908. dot1dTpFdbPort[.113 = 1
  1909. dot1dTpFdbPort[.114 = 1
  1910. dot1dTpFdbPort[.115 = 5
  1911. dot1dTpFdbPort[.116 = 3
  1912. dot1dTpFdbPort[.117 = 1
  1913. dot1dTpFdbPort[.118 = 1
  1914. dot1dTpFdbPort[.119 = 5
  1915. dot1dTpFdbPort[.120 = 4
  1916. dot1dTpFdbPort[.121 = 4
  1917. dot1dTpFdbPort[.122 = 4
  1918. dot1dTpFdbPort[.123 = 10
  1919. dot1dTpFdbPort[.124 = 4
  1920. dot1dTpFdbPort[.125 = 3
  1921. dot1dTpFdbPort[.126 = 1
  1922. dot1dTpFdbPort[.127 = 1
  1923. dot1dTpFdbPort[.128 = 5
  1924. dot1dTpFdbPort[.129 = 3
  1925. dot1dTpFdbPort[.130 = 4
  1926. dot1dTpFdbPort[.131 = 1
  1927. dot1dTpFdbPort[.132 = 1
  1928. dot1dTpFdbPort[.133 = 1
  1929. dot1dTpFdbPort[.134 = 4
  1930. dot1dTpFdbPort[.135 = 5
  1931. dot1dTpFdbPort[.136 = 3
  1932. dot1dTpFdbPort[.137 = 5
  1933. dot1dTpFdbPort[.138 = 1
  1934. dot1dTpFdbPort[.139 = 4
  1935. dot1dTpFdbPort[.140 = 4
  1936. dot1dTpFdbPort[.141 = 4
  1937. dot1dTpFdbPort[.142 = 1
  1938. dot1dTpFdbPort[.143 = 4
  1939. dot1dTpFdbPort[.144 = 1
  1940. dot1dTpFdbPort[.145 = 4
  1941. dot1dTpFdbPort[.146 = 4
  1942. dot1dTpFdbPort[.147 = 4
  1943. dot1dTpFdbPort[.148 = 3
  1944. dot1dTpFdbPort[.149 = 4
  1945. dot1dTpFdbPort[.150 = 3
  1946. dot1dTpFdbPort[.151 = 4
  1947. dot1dTpFdbPort[.152 = 5
  1948. dot1dTpFdbPort[.153 = 5
  1949. dot1dTpFdbPort[.154 = 7
  1950. dot1dTpFdbPort[.155 = 7
  1951. dot1dTpFdbPort[.156 = 7
  1952. dot1dTpFdbPort[.157 = 4
  1953. dot1dTpFdbPort[.158 = 3
  1954. dot1dTpFdbPort[.159 = 4
  1955. dot1dTpFdbPort[.160 = 3
  1956. dot1dTpFdbPort[.161 = 4
  1957. dot1dTpFdbPort[.162 = 3
  1958. dot1dTpFdbPort[.163 = 4
  1959. dot1dTpFdbPort[.164 = 7
  1960. dot1dTpFdbPort[.165 = 1
  1961. dot1dTpFdbPort[.166 = 1
  1962. dot1dTpFdbPort[.167 = 4
  1963. dot1dTpFdbPort[.168 = 4
  1964. dot1dTpFdbPort[.169 = 4
  1965. dot1dTpFdbPort[.170 = 3
  1966. dot1dTpFdbPort[.171 = 4
  1967. dot1dTpFdbPort[.172 = 4
  1968. dot1dTpFdbPort[.173 = 3
  1969. dot1dTpFdbPort[.174 = 4
  1970. dot1dTpFdbPort[.175 = 3
  1971. dot1dTpFdbPort[.176 = 4
  1972. dot1dTpFdbPort[.177 = 1
  1973. dot1dTpFdbPort[.178 = 1
  1974. dot1dTpFdbPort[.179 = 4
  1975. dot1dTpFdbPort[.180 = 3
  1976. dot1dTpFdbPort[.181 = 1
  1977. dot1dTpFdbPort[.182 = 4
  1978. dot1dTpFdbPort[.183 = 4
  1979. dot1dTpFdbPort[.184 = 5
  1980. dot1dTpFdbPort[.185 = 5
  1981. dot1dTpFdbPort[.186 = 4
  1982. dot1dTpFdbPort[.187 = 4
  1983. dot1dTpFdbPort[.188 = 3
  1984. dot1dTpFdbPort[.189 = 4
  1985. dot1dTpFdbPort[.190 = 4
  1986. dot1dTpFdbPort[.191 = 1
  1987. dot1dTpFdbPort[.192 = 1
  1988. dot1dTpFdbPort[.193 = 9
  1989. dot1dTpFdbPort[.194 = 1
  1990. dot1dTpFdbPort[.195 = 1
  1991. dot1dTpFdbPort[.196 = 1
  1992. dot1dTpFdbPort[.197 = 1
  1993. dot1dTpFdbPort[.198 = 1
  1994. dot1dTpFdbPort[.199 = 1
  1995. dot1dTpFdbPort[.200 = 4
  1996. dot1dTpFdbPort[.201 = 1
  1997. dot1dTpFdbPort[.202 = 4
  1998. dot1dTpFdbPort[.203 = 1
  1999. dot1dTpFdbPort[.204 = 1
  2000. dot1dTpFdbPort[.205 = 1
  2001. dot1dTpFdbPort[.206 = 1
  2002. dot1dTpFdbPort[.207 = 1
  2003. dot1dTpFdbPort[.208 = 1
  2004. dot1dTpFdbPort[.209 = 1
  2005. dot1dTpFdbPort[.210 = 1
  2006. dot1dTpFdbPort[.211 = 10
  2007. dot1dTpFdbPort[.212 = 1
  2008. dot1dTpFdbPort[.213 = 1
  2009. dot1dTpFdbPort[.214 = 1
  2010. dot1dTpFdbPort[.215 = 9
  2011. dot1dTpFdbPort[.216 = 1
  2012. dot1dTpFdbPort[.217 = 1
  2013. dot1dTpFdbPort[.218 = 1
  2014. dot1dTpFdbPort[.219 = 1
  2015. dot1dTpFdbPort[.220 = 4
  2016. dot1dTpFdbPort[.221 = 1
  2017. dot1dTpFdbPort[.222 = 5
  2018. dot1dTpFdbPort[.223 = 4
  2019. dot1dTpFdbPort[.224 = 4
  2020. dot1dTpFdbPort[.225 = 7
  2021. dot1dTpFdbPort[.226 = 3
  2022. dot1dTpFdbPort[.227 = 1
  2023. dot1dTpFdbPort[.228 = 4
  2024. dot1dTpFdbPort[.229 = 1
  2025. dot1dTpFdbPort[.230 = 5
  2026. dot1dTpFdbPort[.231 = 4
  2027. dot1dTpFdbPort[.232 = 1
  2028. dot1dTpFdbPort[.233 = 4
  2029. dot1dTpFdbPort[.234 = 1
  2030. dot1dTpFdbPort[.235 = 1
  2031. dot1dTpFdbPort[.236 = 4
  2032. dot1dTpFdbPort[.237 = 4
  2033. dot1dTpFdbPort[.238 = 4
  2034. dot1dTpFdbPort[.239 = 4
  2035. dot1dTpFdbPort[.240 = 4
  2036. dot1dTpFdbPort[.241 = 4
  2037. dot1dTpFdbPort[.242 = 4
  2038. dot1dTpFdbPort[.243 = 3
  2039. dot1dTpFdbPort[.244 = 7
  2040. dot1dTpFdbPort[.245 = 4
  2041. dot1dTpFdbPort[.246 = 4
  2042. dot1dTpFdbPort[.247 = 4
  2043. dot1dTpFdbPort[.248 = 4
  2044. dot1dTpFdbPort[.249 = 3
  2045. dot1dTpFdbPort[.250 = 4
  2046. dot1dTpFdbPort[.251 = 3
  2047. dot1dTpFdbPort[.252 = 1
  2048. dot1dTpFdbPort[.253 = 4
  2049. dot1dTpFdbPort[.254 = 4
  2050. dot1dTpFdbPort[.255 = 4
  2051. dot1dTpFdbPort[.256 = 3
  2052. dot1dTpFdbPort[.257 = 3
  2053. dot1dTpFdbPort[.258 = 3
  2054. dot1dTpFdbPort[.259 = 4
  2055. dot1dTpFdbPort[.260 = 4
  2056. dot1dTpFdbPort[.261 = 4
  2057. dot1dTpFdbPort[.262 = 3
  2058. dot1dTpFdbPort[.263 = 7
  2059. dot1dTpFdbPort[.264 = 4
  2060. dot1dTpFdbPort[.265 = 4
  2061. dot1dTpFdbPort[.266 = 3
  2062. dot1dTpFdbPort[.267 = 4
  2063. dot1dTpFdbPort[.268 = 4
  2064. dot1dTpFdbPort[.269 = 4
  2065. dot1dTpFdbPort[.270 = 4
  2066. dot1dTpFdbPort[.271 = 4
  2067. dot1dTpFdbPort[.272 = 4
  2068. dot1dTpFdbPort[.273 = 4
  2069. dot1dTpFdbPort[.274 = 7
  2070. dot1dTpFdbPort[.275 = 4
  2071. dot1dTpFdbPort[.276 = 1
  2072. dot1dTpFdbPort[.277 = 4
  2073. dot1dTpFdbPort[.278 = 1
  2074. dot1dTpFdbPort[.279 = 1
  2075. dot1dTpFdbPort[.280 = 1
  2076. dot1dTpFdbPort[.281 = 1
  2077. dot1dTpFdbPort[.282 = 1
  2078. dot1dTpFdbPort[.283 = 1
  2079. dot1dTpFdbPort[.284 = 1
  2080. dot1dTpFdbPort[.285 = 4
  2081. dot1dTpFdbPort[.286 = 5
  2082. dot1dTpFdbPort[.287 = 1
  2083. dot1dTpFdbPort[.288 = 5
  2084. dot1dTpFdbPort[.289 = 4
  2085. dot1dTpFdbPort[.290 = 1
  2086. dot1dTpFdbPort[.291 = 1
  2087. dot1dTpFdbPort[.292 = 4
  2088. dot1dTpFdbPort[.293 = 1
  2089. dot1dTpFdbPort[.294 = 1
  2090. dot1dTpFdbPort[.295 = 1
  2091. dot1dTpFdbPort[.296 = 1
  2092. dot1dTpFdbPort[.297 = 1
  2093. dot1dTpFdbPort[.298 = 4
  2094. dot1dTpFdbPort[.299 = 1
  2095. dot1dTpFdbPort[.300 = 1
  2096. dot1dTpFdbPort[.301 = 1
  2097. dot1dTpFdbPort[.302 = 1
  2098. dot1dTpFdbPort[.303 = 1
  2099. dot1dTpFdbPort[.304 = 1
  2100. dot1dTpFdbPort[.305 = 1
  2101. dot1dTpFdbPort[.306 = 4
  2102. dot1dTpFdbPort[.307 = 1
  2103. dot1dTpFdbPort[.308 = 4
  2104. dot1dTpFdbPort[.309 = 1
  2105. dot1dTpFdbPort[.310 = 1
  2106. dot1dTpFdbPort[.311 = 4
  2107. dot1dTpFdbPort[.312 = 1
  2108. dot1dTpFdbPort[.313 = 1
  2109. dot1dTpFdbPort[.314 = 1
  2110. dot1dTpFdbPort[.315 = 1
  2111. dot1dTpFdbPort[.316 = 4
  2112. dot1dTpFdbPort[.317 = 5
  2113. dot1dTpFdbPort[.318 = 3
  2114. dot1dTpFdbPort[.319 = 4
  2115. dot1dTpFdbPort[.320 = 1
  2116. dot1dTpFdbPort[.321 = 1
  2117. dot1dTpFdbPort[.322 = 4
  2118. dot1dTpFdbPort[.323 = 4
  2119. dot1dTpFdbPort[.324 = 4
  2120. dot1dTpFdbPort[.325 = 0
  2121. dot1dTpFdbPort[.326 = 5
  2122.  
  2123. BRIDGE-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/netonix udp:HOSTNAME:161 dot1dBasePortIfIndex]
  2124. dot1dBasePortIfIndex[1] = 1
  2125. dot1dBasePortIfIndex[2] = 2
  2126. dot1dBasePortIfIndex[3] = 3
  2127. dot1dBasePortIfIndex[4] = 4
  2128. dot1dBasePortIfIndex[5] = 5
  2129. dot1dBasePortIfIndex[6] = 6
  2130. dot1dBasePortIfIndex[7] = 7
  2131. dot1dBasePortIfIndex[8] = 8
  2132. dot1dBasePortIfIndex[9] = 9
  2133. dot1dBasePortIfIndex[10] = 10
  2134. dot1dBasePortIfIndex[11] = 11
  2135. dot1dBasePortIfIndex[12] = 12
  2136. dot1dBasePortIfIndex[13] = 13
  2137. dot1dBasePortIfIndex[14] = 14
  2138.  
  2139. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '1']
  2140. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '2']
  2141. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '3']
  2142. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '4']
  2143. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '5']
  2144. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '6']
  2145. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '7']
  2146. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '8']
  2147. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '9']
  2148. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '10']
  2149. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '11']
  2150. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '12']
  2151. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '13']
  2152. SQL[SELECT * FROM `ports` WHERE `device_id` = '25' AND `ifIndex` = '14']
  2153. No port known for .1
  2154. MAC address padding failed for .2
  2155. MAC address padding failed for .3
  2156. MAC address padding failed for .4
  2157. MAC address padding failed for .5
  2158. MAC address padding failed for .6
  2159. MAC address padding failed for .7
  2160. MAC address padding failed for .8
  2161. MAC address padding failed for .9
  2162. MAC address padding failed for .10
  2163. MAC address padding failed for .11
  2164. MAC address padding failed for .12
  2165. MAC address padding failed for .13
  2166. MAC address padding failed for .14
  2167. MAC address padding failed for .15
  2168. MAC address padding failed for .16
  2169. MAC address padding failed for .17
  2170. MAC address padding failed for .18
  2171. MAC address padding failed for .19
  2172. MAC address padding failed for .20
  2173. MAC address padding failed for .21
  2174. MAC address padding failed for .22
  2175. MAC address padding failed for .23
  2176. MAC address padding failed for .24
  2177. MAC address padding failed for .25
  2178. MAC address padding failed for .26
  2179. MAC address padding failed for .27
  2180. MAC address padding failed for .28
  2181. MAC address padding failed for .29
  2182. MAC address padding failed for .30
  2183. MAC address padding failed for .31
  2184. MAC address padding failed for .32
  2185. MAC address padding failed for .33
  2186. MAC address padding failed for .34
  2187. MAC address padding failed for .35
  2188. MAC address padding failed for .36
  2189. MAC address padding failed for .37
  2190. MAC address padding failed for .38
  2191. MAC address padding failed for .39
  2192. MAC address padding failed for .40
  2193. MAC address padding failed for .41
  2194. MAC address padding failed for .42
  2195. MAC address padding failed for .43
  2196. MAC address padding failed for .44
  2197. MAC address padding failed for .45
  2198. MAC address padding failed for .46
  2199. MAC address padding failed for .47
  2200. MAC address padding failed for .48
  2201. MAC address padding failed for .49
  2202. MAC address padding failed for .50
  2203. MAC address padding failed for .51
  2204. MAC address padding failed for .52
  2205. MAC address padding failed for .53
  2206. MAC address padding failed for .54
  2207. MAC address padding failed for .55
  2208. MAC address padding failed for .56
  2209. MAC address padding failed for .57
  2210. MAC address padding failed for .58
  2211. MAC address padding failed for .59
  2212. MAC address padding failed for .60
  2213. MAC address padding failed for .61
  2214. MAC address padding failed for .62
  2215. MAC address padding failed for .63
  2216. MAC address padding failed for .64
  2217. MAC address padding failed for .65
  2218. MAC address padding failed for .66
  2219. MAC address padding failed for .67
  2220. MAC address padding failed for .68
  2221. MAC address padding failed for .69
  2222. MAC address padding failed for .70
  2223. MAC address padding failed for .71
  2224. MAC address padding failed for .72
  2225. MAC address padding failed for .73
  2226. MAC address padding failed for .74
  2227. MAC address padding failed for .75
  2228. MAC address padding failed for .76
  2229. MAC address padding failed for .77
  2230. MAC address padding failed for .78
  2231. MAC address padding failed for .79
  2232. MAC address padding failed for .80
  2233. MAC address padding failed for .81
  2234. MAC address padding failed for .82
  2235. MAC address padding failed for .83
  2236. MAC address padding failed for .84
  2237. MAC address padding failed for .85
  2238. MAC address padding failed for .86
  2239. MAC address padding failed for .87
  2240. MAC address padding failed for .88
  2241. MAC address padding failed for .89
  2242. MAC address padding failed for .90
  2243. MAC address padding failed for .91
  2244. MAC address padding failed for .92
  2245. MAC address padding failed for .93
  2246. MAC address padding failed for .94
  2247. MAC address padding failed for .95
  2248. MAC address padding failed for .96
  2249. MAC address padding failed for .97
  2250. MAC address padding failed for .98
  2251. MAC address padding failed for .99
  2252. MAC address padding failed for .100
  2253. MAC address padding failed for .101
  2254. MAC address padding failed for .102
  2255. MAC address padding failed for .103
  2256. MAC address padding failed for .104
  2257. MAC address padding failed for .105
  2258. MAC address padding failed for .106
  2259. MAC address padding failed for .107
  2260. MAC address padding failed for .108
  2261. MAC address padding failed for .109
  2262. MAC address padding failed for .110
  2263. MAC address padding failed for .111
  2264. MAC address padding failed for .112
  2265. MAC address padding failed for .113
  2266. MAC address padding failed for .114
  2267. MAC address padding failed for .115
  2268. MAC address padding failed for .116
  2269. MAC address padding failed for .117
  2270. MAC address padding failed for .118
  2271. MAC address padding failed for .119
  2272. MAC address padding failed for .120
  2273. MAC address padding failed for .121
  2274. MAC address padding failed for .122
  2275. MAC address padding failed for .123
  2276. MAC address padding failed for .124
  2277. MAC address padding failed for .125
  2278. MAC address padding failed for .126
  2279. MAC address padding failed for .127
  2280. MAC address padding failed for .128
  2281. MAC address padding failed for .129
  2282. MAC address padding failed for .130
  2283. MAC address padding failed for .131
  2284. MAC address padding failed for .132
  2285. MAC address padding failed for .133
  2286. MAC address padding failed for .134
  2287. MAC address padding failed for .135
  2288. MAC address padding failed for .136
  2289. MAC address padding failed for .137
  2290. MAC address padding failed for .138
  2291. MAC address padding failed for .139
  2292. MAC address padding failed for .140
  2293. MAC address padding failed for .141
  2294. MAC address padding failed for .142
  2295. MAC address padding failed for .143
  2296. MAC address padding failed for .144
  2297. MAC address padding failed for .145
  2298. MAC address padding failed for .146
  2299. MAC address padding failed for .147
  2300. MAC address padding failed for .148
  2301. MAC address padding failed for .149
  2302. MAC address padding failed for .150
  2303. MAC address padding failed for .151
  2304. MAC address padding failed for .152
  2305. MAC address padding failed for .153
  2306. MAC address padding failed for .154
  2307. MAC address padding failed for .155
  2308. MAC address padding failed for .156
  2309. MAC address padding failed for .157
  2310. MAC address padding failed for .158
  2311. MAC address padding failed for .159
  2312. MAC address padding failed for .160
  2313. MAC address padding failed for .161
  2314. MAC address padding failed for .162
  2315. MAC address padding failed for .163
  2316. MAC address padding failed for .164
  2317. MAC address padding failed for .165
  2318. MAC address padding failed for .166
  2319. MAC address padding failed for .167
  2320. MAC address padding failed for .168
  2321. MAC address padding failed for .169
  2322. MAC address padding failed for .170
  2323. MAC address padding failed for .171
  2324. MAC address padding failed for .172
  2325. MAC address padding failed for .173
  2326. MAC address padding failed for .174
  2327. MAC address padding failed for .175
  2328. MAC address padding failed for .176
  2329. MAC address padding failed for .177
  2330. MAC address padding failed for .178
  2331. MAC address padding failed for .179
  2332. MAC address padding failed for .180
  2333. MAC address padding failed for .181
  2334. MAC address padding failed for .182
  2335. MAC address padding failed for .183
  2336. MAC address padding failed for .184
  2337. MAC address padding failed for .185
  2338. MAC address padding failed for .186
  2339. MAC address padding failed for .187
  2340. MAC address padding failed for .188
  2341. MAC address padding failed for .189
  2342. MAC address padding failed for .190
  2343. MAC address padding failed for .191
  2344. MAC address padding failed for .192
  2345. MAC address padding failed for .193
  2346. MAC address padding failed for .194
  2347. MAC address padding failed for .195
  2348. MAC address padding failed for .196
  2349. MAC address padding failed for .197
  2350. MAC address padding failed for .198
  2351. MAC address padding failed for .199
  2352. MAC address padding failed for .200
  2353. MAC address padding failed for .201
  2354. MAC address padding failed for .202
  2355. MAC address padding failed for .203
  2356. MAC address padding failed for .204
  2357. MAC address padding failed for .205
  2358. MAC address padding failed for .206
  2359. MAC address padding failed for .207
  2360. MAC address padding failed for .208
  2361. MAC address padding failed for .209
  2362. MAC address padding failed for .210
  2363. MAC address padding failed for .211
  2364. MAC address padding failed for .212
  2365. MAC address padding failed for .213
  2366. MAC address padding failed for .214
  2367. MAC address padding failed for .215
  2368. MAC address padding failed for .216
  2369. MAC address padding failed for .217
  2370. MAC address padding failed for .218
  2371. MAC address padding failed for .219
  2372. MAC address padding failed for .220
  2373. MAC address padding failed for .221
  2374. MAC address padding failed for .222
  2375. MAC address padding failed for .223
  2376. MAC address padding failed for .224
  2377. MAC address padding failed for .225
  2378. MAC address padding failed for .226
  2379. MAC address padding failed for .227
  2380. MAC address padding failed for .228
  2381. MAC address padding failed for .229
  2382. MAC address padding failed for .230
  2383. MAC address padding failed for .231
  2384. MAC address padding failed for .232
  2385. MAC address padding failed for .233
  2386. MAC address padding failed for .234
  2387. MAC address padding failed for .235
  2388. MAC address padding failed for .236
  2389. MAC address padding failed for .237
  2390. MAC address padding failed for .238
  2391. MAC address padding failed for .239
  2392. MAC address padding failed for .240
  2393. MAC address padding failed for .241
  2394. MAC address padding failed for .242
  2395. MAC address padding failed for .243
  2396. MAC address padding failed for .244
  2397. MAC address padding failed for .245
  2398. MAC address padding failed for .246
  2399. MAC address padding failed for .247
  2400. MAC address padding failed for .248
  2401. MAC address padding failed for .249
  2402. MAC address padding failed for .250
  2403. MAC address padding failed for .251
  2404. MAC address padding failed for .252
  2405. MAC address padding failed for .253
  2406. MAC address padding failed for .254
  2407. MAC address padding failed for .255
  2408. MAC address padding failed for .256
  2409. MAC address padding failed for .257
  2410. MAC address padding failed for .258
  2411. MAC address padding failed for .259
  2412. MAC address padding failed for .260
  2413. MAC address padding failed for .261
  2414. MAC address padding failed for .262
  2415. MAC address padding failed for .263
  2416. MAC address padding failed for .264
  2417. MAC address padding failed for .265
  2418. MAC address padding failed for .266
  2419. MAC address padding failed for .267
  2420. MAC address padding failed for .268
  2421. MAC address padding failed for .269
  2422. MAC address padding failed for .270
  2423. MAC address padding failed for .271
  2424. MAC address padding failed for .272
  2425. MAC address padding failed for .273
  2426. MAC address padding failed for .274
  2427. MAC address padding failed for .275
  2428. MAC address padding failed for .276
  2429. MAC address padding failed for .277
  2430. MAC address padding failed for .278
  2431. MAC address padding failed for .279
  2432. MAC address padding failed for .280
  2433. MAC address padding failed for .281
  2434. MAC address padding failed for .282
  2435. MAC address padding failed for .283
  2436. MAC address padding failed for .284
  2437. MAC address padding failed for .285
  2438. MAC address padding failed for .286
  2439. MAC address padding failed for .287
  2440. MAC address padding failed for .288
  2441. MAC address padding failed for .289
  2442. MAC address padding failed for .290
  2443. MAC address padding failed for .291
  2444. MAC address padding failed for .292
  2445. MAC address padding failed for .293
  2446. MAC address padding failed for .294
  2447. MAC address padding failed for .295
  2448. MAC address padding failed for .296
  2449. MAC address padding failed for .297
  2450. MAC address padding failed for .298
  2451. MAC address padding failed for .299
  2452. MAC address padding failed for .300
  2453. MAC address padding failed for .301
  2454. MAC address padding failed for .302
  2455. MAC address padding failed for .303
  2456. MAC address padding failed for .304
  2457. MAC address padding failed for .305
  2458. MAC address padding failed for .306
  2459. MAC address padding failed for .307
  2460. MAC address padding failed for .308
  2461. MAC address padding failed for .309
  2462. MAC address padding failed for .310
  2463. MAC address padding failed for .311
  2464. MAC address padding failed for .312
  2465. MAC address padding failed for .313
  2466. MAC address padding failed for .314
  2467. MAC address padding failed for .315
  2468. MAC address padding failed for .316
  2469. MAC address padding failed for .317
  2470. MAC address padding failed for .318
  2471. MAC address padding failed for .319
  2472. MAC address padding failed for .320
  2473. MAC address padding failed for .321
  2474. MAC address padding failed for .322
  2475. MAC address padding failed for .323
  2476. MAC address padding failed for .324
  2477. No port known for .325
  2478. MAC address padding failed for .326
  2479.  
  2480.  
  2481. >> Runtime for discovery module 'fdb-table': 0.2950 seconds with 255688 bytes
  2482. #### Unload disco module fdb-table ####
  2483.  
  2484. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '25' AND `attrib_type` = 'poll_mib' ]
  2485. SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='2.895' WHERE `device_id` = '25']
  2486. Discovered in 2.895 seconds
  2487.  
  2488. SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','$HOSTNAME','1503619500.8179','2.948','1','orwell\n')]
  2489. /opt/librenms/discovery.php $HOSTNAME 2017-08-25 10:05:03 - 1 devices discovered in 2.948 secs
  2490. SNMP: Get[11/0.22s] Walk [34/1.44s]
  2491. MySQL: Cell[112/0.02s] Row[81/0.01s] Rows[72/0.02s] Column[1/0.00s] Update[4/0.02s] Insert[16/0.14s] Delete[0/0.00s]
  2492.