ℹ️ Your data is safe here... unless you make the SNIP gods angry. And let's just say they have a really bad sense of humor.

From sikasa, 2 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 0.41ms]
  3.  
  4. SQL[[1;33mselect count(*) as aggregate from `migrations` limit 1 [0;33m[][0m 0.45ms]
  5.  
  6. SQL[[1;33mselect version() [0;33m[][0m 0.31ms]
  7.  
  8. ===================================
  9. Version info:
  10. Commit SHA: 2e35844056657a2535c1e1f5716e0e3d4862bc1c
  11. Commit Date: 1644185607
  12. DB Schema: 2021_12_02_113537_ports_stp_designated_cost_change_to_int (234)
  13. PHP: 7.4.3
  14. MySQL: 10.3.32-MariaDB-0ubuntu0.20.04.1
  15. RRDTool: 1.7.2
  16. SNMP: 5.8
  17. ==================================DEBUG!
  18. Updating os_def.cache  
  19. SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE 'brapciscoosa000.br.sika.com' ORDER BY device_id DESC [0;33m[][0m 1.1ms]
  20.  
  21. SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[3][0m 0.57ms]
  22.  
  23. SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[3][0m 0.5ms]
  24.  
  25. brapciscoosa000.br.sika.com 3 ciscowlc [FPING] '/usr/bin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' 'brapciscoosa000.br.sika.com'
  26.  
  27. response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.62/0.81/1.19  
  28. SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'[0m]  
  29. SNMPv2-MIB::sysObjectID.0 = SNMPv2-SMI::enterprises.9.1.2370
  30.  
  31.  
  32. Modules status: Global+  
  33. OS  
  34. Device  
  35.  
  36. #### Load disco module core ####
  37. Attempting to initialize OS: ciscowlc  
  38. OS initialized: LibreNMS\OS\Ciscowlc  
  39. SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0'[0m]  
  40. .*.*.0 = .*.*.2370
  41. .*.*.0 = Cisco Controller
  42. .*.*.0 = BRAP-2802M01
  43.  
  44.  
  45. | Cisco Controller | .1.3.6.1.4.1.9.1.2370 |
  46.  
  47. OS: Cisco WLC (ciscowlc)
  48.  
  49. Attempting to initialize OS: ciscowlc  
  50. OS initialized: LibreNMS\OS\Ciscowlc  
  51.  
  52. >> Runtime for discovery module 'core': 0.0330 seconds with 27200 bytes
  53. >> [0;36mSNMP[0m: [1/0.02s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  54. #### Unload disco module core ####
  55.  
  56. Modules status: Global+  
  57. OS  
  58. Device  
  59.  
  60. #### Load disco module os ####
  61. Yaml location data:  
  62. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'[0m]
  63.  
  64.  
  65. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'sysContact.0'[0m]
  66.  
  67.  
  68. SNMP[[0;36m'/usr/bin/snmptranslate' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-m' 'CISCO-PRODUCTS-MIB' '-Os' '.1.3.6.1.4.1.9.1.2370'[0m]
  69. ciscoProducts.2370  
  70.  
  71. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ENTITY-MIB::entPhysicalModelName.1' 'ENTITY-MIB::entPhysicalName.1' 'ENTITY-MIB::entPhysicalSoftwareRev.1' 'ENTITY-MIB::entPhysicalSerialNum.1'[0m]
  72. ENTITY-MIB::entPhysicalModelName.1 = AIR-AP2802I-Z-K9
  73. ENTITY-MIB::entPhysicalName.1 = Mobility Express
  74. ENTITY-MIB::entPhysicalSoftwareRev.1 = *
  75. ENTITY-MIB::entPhysicalSerialNum.1 = TSP2405AAAU  
  76.  
  77. Yaml OS data: {"ENTITY-MIB::entPhysicalModelName.1":"AIR-AP2802I-Z-K9","ENTITY-MIB::entPhysicalName.1":"Mobility Express","ENTITY-MIB::entPhysicalSoftwareRev.1":"8.10.142.0","ENTITY-MIB::entPhysicalSerialNum.1":"TSP2405AAAU"}
  78. Location:
  79. Hardware: AIR-AP2802I-Z-K9
  80. OS Version: 8.10.142.0
  81. OS Features:
  82. Serial: TSP2405AAAU
  83.  
  84. >> Runtime for discovery module 'os': 0.0980 seconds with 252320 bytes
  85. >> [0;36mSNMP[0m: [5/0.09s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  86. #### Unload disco module os ####
  87.  
  88. Modules status: Global+  
  89. OS  
  90. Device  
  91.  
  92. #### Load disco module ports ####
  93. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifDescr'[0m]
  94. ifDescr.1 = Unit: 0 Slot: 0 Port: 1 Gigabit - Level 0x8010001
  95. ifDescr.2 = Virtual Interface  
  96.  
  97. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifName'[0m]
  98. ifName.1 = GigabitEthernet0/0/1
  99. ifName.2 = Virtual Interface  
  100.  
  101. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifAlias'[0m]
  102. ifAlias = No Such Instance currently exists at this OID  
  103.  
  104. Invalid snmp_walk() data = ifAlias = No Such Instance currently exists at this OID  
  105. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifType'[0m]
  106. ifType.1 = ethernetCsmacd
  107. ifType.2 = ethernetCsmacd  
  108.  
  109. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifOperStatus'[0m]
  110. ifOperStatus.1 = up
  111. ifOperStatus.2 = up  
  112.  
  113. array (
  114.   1 =>
  115.   array (
  116.     'ifDescr' => 'Unit: 0 Slot: 0 Port: 1 Gigabit - Level 0x8010001',
  117.     'ifName' => 'GigabitEthernet0/0/1',
  118.     'ifType' => 'ethernetCsmacd',
  119.     'ifOperStatus' => 'up',
  120.   ),
  121.   2 =>
  122.   array (
  123.     'ifDescr' => 'Virtual Interface',
  124.     'ifName' => 'Virtual Interface',
  125.     'ifType' => 'ethernetCsmacd',
  126.     'ifOperStatus' => 'up',
  127.   ),
  128. )  
  129. SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[3][0m 1.26ms]
  130.  
  131.  Using ifDescr as ifAlias  
  132. SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=? WHERE `port_id` = ? [0;33m["Unit: 0 Slot: 0 Port: 1 Gigabit - Level 0x8010001","GigabitEthernet0\/0\/1","ethernetCsmacd","up",1,"Unit: 0 Slot: 0 Port: 1 Gigabit - Level 0x8010001",44][0m 0.4ms]
  133.  
  134. .ignored by ifDescr: Virtual Interface (matched: irtual)  
  135. X
  136.  
  137. >> Runtime for discovery module 'ports': 0.0940 seconds with 8656 bytes
  138. >> [0;36mSNMP[0m: [5/0.09s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.00s]  
  139. #### Unload disco module ports ####
  140.  
  141. Modules status: Global+  
  142. OS  
  143. Device  
  144.  
  145. #### Load disco module ports-stack ####
  146. SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '3' [0;33m[][0m 0.34ms]
  147.  
  148. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ifStackStatus'[0m]
  149. ifStackStatus = No Such Instance currently exists at this OID  
  150.  
  151.  
  152.  
  153. >> Runtime for discovery module 'ports-stack': 0.0200 seconds with 744 bytes
  154. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]  
  155. #### Unload disco module ports-stack ####
  156.  
  157. Modules status: Global+  
  158. OS  
  159. Device  
  160.  
  161. #### Load disco module entity-physical ####
  162.  
  163. Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m]
  164. entPhysicalDescr.1 = Cisco Aironet 2800 Series Mobility Express
  165. entPhysicalDescr.8 = Cisco Aironet 2800 Series (IEEE 802.11ac) Access Point
  166. entPhysicalDescr.448 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  167. entPhysicalDescr.48 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  168. entPhysicalDescr.504 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  169. entPhysicalDescr.296 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  170. entPhysicalDescr.336 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  171. entPhysicalDescr.584 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  172. entPhysicalDescr.24 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  173. entPhysicalDescr.480 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  174. entPhysicalDescr.128 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  175. entPhysicalDescr.792 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  176. entPhysicalDescr.768 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  177. entPhysicalDescr.712 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  178. entPhysicalDescr.496 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  179. entPhysicalDescr.664 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  180. entPhysicalDescr.376 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  181. entPhysicalDescr.320 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  182. entPhysicalDescr.640 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  183. entPhysicalDescr.240 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  184. entPhysicalDescr.168 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  185. entPhysicalDescr.416 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  186. entPhysicalDescr.632 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  187. entPhysicalDescr.528 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  188. entPhysicalDescr.256 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  189. entPhysicalDescr.144 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  190. entPhysicalDescr.216 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  191. entPhysicalDescr.368 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  192. entPhysicalDescr.248 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  193. entPhysicalDescr.136 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  194. entPhysicalDescr.40 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  195. entPhysicalDescr.208 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  196. entPhysicalDescr.192 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  197. entPhysicalDescr.720 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  198. entPhysicalDescr.288 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  199. entPhysicalDescr.384 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  200. entPhysicalContainedIn.1 = 0
  201. entPhysicalContainedIn.8 = 0
  202. entPhysicalContainedIn.448 = 0
  203. entPhysicalContainedIn.48 = 0
  204. entPhysicalContainedIn.504 = 0
  205. entPhysicalContainedIn.296 = 0
  206. entPhysicalContainedIn.336 = 0
  207. entPhysicalContainedIn.584 = 0
  208. entPhysicalContainedIn.24 = 0
  209. entPhysicalContainedIn.480 = 0
  210. entPhysicalContainedIn.128 = 0
  211. entPhysicalContainedIn.792 = 0
  212. entPhysicalContainedIn.768 = 0
  213. entPhysicalContainedIn.712 = 0
  214. entPhysicalContainedIn.496 = 0
  215. entPhysicalContainedIn.664 = 0
  216. entPhysicalContainedIn.376 = 0
  217. entPhysicalContainedIn.320 = 0
  218. entPhysicalContainedIn.640 = 0
  219. entPhysicalContainedIn.240 = 0
  220. entPhysicalContainedIn.168 = 0
  221. entPhysicalContainedIn.416 = 0
  222. entPhysicalContainedIn.632 = 0
  223. entPhysicalContainedIn.528 = 0
  224. entPhysicalContainedIn.256 = 0
  225. entPhysicalContainedIn.144 = 0
  226. entPhysicalContainedIn.216 = 0
  227. entPhysicalContainedIn.368 = 0
  228. entPhysicalContainedIn.248 = 0
  229. entPhysicalContainedIn.136 = 0
  230. entPhysicalContainedIn.40 = 0
  231. entPhysicalContainedIn.208 = 0
  232. entPhysicalContainedIn.192 = 0
  233. entPhysicalContainedIn.720 = 0
  234. entPhysicalContainedIn.288 = 0
  235. entPhysicalContainedIn.384 = 0
  236. entPhysicalParentRelPos.1 = -1
  237. entPhysicalParentRelPos.8 = -1
  238. entPhysicalParentRelPos.448 = -1
  239. entPhysicalParentRelPos.48 = -1
  240. entPhysicalParentRelPos.504 = -1
  241. entPhysicalParentRelPos.296 = -1
  242. entPhysicalParentRelPos.336 = -1
  243. entPhysicalParentRelPos.584 = -1
  244. entPhysicalParentRelPos.24 = -1
  245. entPhysicalParentRelPos.480 = -1
  246. entPhysicalParentRelPos.128 = -1
  247. entPhysicalParentRelPos.792 = -1
  248. entPhysicalParentRelPos.768 = -1
  249. entPhysicalParentRelPos.712 = -1
  250. entPhysicalParentRelPos.496 = -1
  251. entPhysicalParentRelPos.664 = -1
  252. entPhysicalParentRelPos.376 = -1
  253. entPhysicalParentRelPos.320 = -1
  254. entPhysicalParentRelPos.640 = -1
  255. entPhysicalParentRelPos.240 = -1
  256. entPhysicalParentRelPos.168 = -1
  257. entPhysicalParentRelPos.416 = -1
  258. entPhysicalParentRelPos.632 = -1
  259. entPhysicalParentRelPos.528 = -1
  260. entPhysicalParentRelPos.256 = -1
  261. entPhysicalParentRelPos.144 = -1
  262. entPhysicalParentRelPos.216 = -1
  263. entPhysicalParentRelPos.368 = -1
  264. entPhysicalParentRelPos.248 = -1
  265. entPhysicalParentRelPos.136 = -1
  266. entPhysicalParentRelPos.40 = -1
  267. entPhysicalParentRelPos.208 = -1
  268. entPhysicalParentRelPos.192 = -1
  269. entPhysicalParentRelPos.720 = -1
  270. entPhysicalParentRelPos.288 = -1
  271. entPhysicalParentRelPos.384 = -1
  272. entPhysicalName.1 = Mobility Express
  273. entPhysicalName.8 = AP2800
  274. entPhysicalName.448 = AP2700
  275. entPhysicalName.48 = AP2700
  276. entPhysicalName.504 = AP2700
  277. entPhysicalName.296 = AP2700
  278. entPhysicalName.336 = AP2700
  279. entPhysicalName.584 = AP2700
  280. entPhysicalName.24 = AP2700
  281. entPhysicalName.480 = AP2700
  282. entPhysicalName.128 = AP2700
  283. entPhysicalName.792 = AP2700
  284. entPhysicalName.768 = AP2700
  285. entPhysicalName.712 = AP2700
  286. entPhysicalName.496 = AP2700
  287. entPhysicalName.664 = AP2700
  288. entPhysicalName.376 = AP2700
  289. entPhysicalName.320 = AP2700
  290. entPhysicalName.640 = AP2700
  291. entPhysicalName.240 = AP2700
  292. entPhysicalName.168 = AP2700
  293. entPhysicalName.416 = AP2700
  294. entPhysicalName.632 = AP2700
  295. entPhysicalName.528 = AP2700
  296. entPhysicalName.256 = AP2700
  297. entPhysicalName.144 = AP2700
  298. entPhysicalName.216 = AP2700
  299. entPhysicalName.368 = AP2700
  300. entPhysicalName.248 = AP2700
  301. entPhysicalName.136 = AP2700
  302. entPhysicalName.40 = AP2700
  303. entPhysicalName.208 = AP2700
  304. entPhysicalName.192 = AP2700
  305. entPhysicalName.720 = AP2700
  306. entPhysicalName.288 = AP2700
  307. entPhysicalName.384 = AP2700
  308. entPhysicalHardwareRev.1 = V03
  309. entPhysicalHardwareRev.8 = V03
  310. entPhysicalHardwareRev.448 = V04
  311. entPhysicalHardwareRev.48 = V04
  312. entPhysicalHardwareRev.504 = V04
  313. entPhysicalHardwareRev.296 = V04
  314. entPhysicalHardwareRev.336 = V04
  315. entPhysicalHardwareRev.584 = V04
  316. entPhysicalHardwareRev.24 = V04
  317. entPhysicalHardwareRev.480 = V04
  318. entPhysicalHardwareRev.128 = V04
  319. entPhysicalHardwareRev.792 = V04
  320. entPhysicalHardwareRev.768 = V04
  321. entPhysicalHardwareRev.712 = V04
  322. entPhysicalHardwareRev.496 = V04
  323. entPhysicalHardwareRev.664 = V04
  324. entPhysicalHardwareRev.376 = V04
  325. entPhysicalHardwareRev.320 = V04
  326. entPhysicalHardwareRev.640 = V04
  327. entPhysicalHardwareRev.240 = V04
  328. entPhysicalHardwareRev.168 = V04
  329. entPhysicalHardwareRev.416 = V04
  330. entPhysicalHardwareRev.632 = V02
  331. entPhysicalHardwareRev.528 = V02
  332. entPhysicalHardwareRev.256 = V02
  333. entPhysicalHardwareRev.144 = V02
  334. entPhysicalHardwareRev.216 = V02
  335. entPhysicalHardwareRev.368 = V04
  336. entPhysicalHardwareRev.248 = V02
  337. entPhysicalHardwareRev.136 = V02
  338. entPhysicalHardwareRev.40 = V02
  339. entPhysicalHardwareRev.208 = V04
  340. entPhysicalHardwareRev.192 = V02
  341. entPhysicalHardwareRev.720 = V04
  342. entPhysicalHardwareRev.288 = V04
  343. entPhysicalHardwareRev.384 = V04
  344. entPhysicalSoftwareRev.1 = *
  345. entPhysicalSoftwareRev.8 = *
  346. entPhysicalSoftwareRev.448 = *
  347. entPhysicalSoftwareRev.48 = *
  348. entPhysicalSoftwareRev.504 = *
  349. entPhysicalSoftwareRev.296 = *
  350. entPhysicalSoftwareRev.336 = *
  351. entPhysicalSoftwareRev.584 = *
  352. entPhysicalSoftwareRev.24 = *
  353. entPhysicalSoftwareRev.480 = *
  354. entPhysicalSoftwareRev.128 = *
  355. entPhysicalSoftwareRev.792 = *
  356. entPhysicalSoftwareRev.768 = *
  357. entPhysicalSoftwareRev.712 = *
  358. entPhysicalSoftwareRev.496 = *
  359. entPhysicalSoftwareRev.664 = *
  360. entPhysicalSoftwareRev.376 = *
  361. entPhysicalSoftwareRev.320 = *
  362. entPhysicalSoftwareRev.640 = *
  363. entPhysicalSoftwareRev.240 = *
  364. entPhysicalSoftwareRev.168 = *
  365. entPhysicalSoftwareRev.416 = *
  366. entPhysicalSoftwareRev.632 = *
  367. entPhysicalSoftwareRev.528 = *
  368. entPhysicalSoftwareRev.256 = *
  369. entPhysicalSoftwareRev.144 = *
  370. entPhysicalSoftwareRev.216 = *
  371. entPhysicalSoftwareRev.368 = *
  372. entPhysicalSoftwareRev.248 = *
  373. entPhysicalSoftwareRev.136 = *
  374. entPhysicalSoftwareRev.40 = *
  375. entPhysicalSoftwareRev.208 = *
  376. entPhysicalSoftwareRev.192 = *
  377. entPhysicalSoftwareRev.720 = *
  378. entPhysicalSoftwareRev.288 = *
  379. entPhysicalSoftwareRev.384 = *
  380. entPhysicalSerialNum.1 = TSP2405AAAU
  381. entPhysicalSerialNum.8 = TSP2405AAAU
  382. entPhysicalSerialNum.448 = TSP2234AKPP
  383. entPhysicalSerialNum.48 = TSP2235ACDJ
  384. entPhysicalSerialNum.504 = TSP2235ACDG
  385. entPhysicalSerialNum.296 = TSP2237AFSF
  386. entPhysicalSerialNum.336 = TSP2235ABLU
  387. entPhysicalSerialNum.584 = TSP2234ALCL
  388. entPhysicalSerialNum.24 = TSP2235ABKZ
  389. entPhysicalSerialNum.480 = TSP2235ABLB
  390. entPhysicalSerialNum.128 = TSP2237ADUU
  391. entPhysicalSerialNum.792 = TSP2238AABS
  392. entPhysicalSerialNum.768 = TSP2235ABKM
  393. entPhysicalSerialNum.712 = TSP2235ACDD
  394. entPhysicalSerialNum.496 = TSP2234ALCP
  395. entPhysicalSerialNum.664 = TSP2237AFSJ
  396. entPhysicalSerialNum.376 = TSP2234ALNM
  397. entPhysicalSerialNum.320 = TSP2235ACCU
  398. entPhysicalSerialNum.640 = TSP2234AHGF
  399. entPhysicalSerialNum.240 = TSP2235ACDP
  400. entPhysicalSerialNum.168 = TSP2235ACFU
  401. entPhysicalSerialNum.416 = TSP2237ADMN
  402. entPhysicalSerialNum.632 = TSP2022AAAA
  403. entPhysicalSerialNum.528 = TSP2022AAKZ
  404. entPhysicalSerialNum.256 = TSP2022AALD
  405. entPhysicalSerialNum.144 = TSP2022AAKC
  406. entPhysicalSerialNum.216 = TSP2022AAKT
  407. entPhysicalSerialNum.368 = TSP2238AACB
  408. entPhysicalSerialNum.248 = TSP2022AALC
  409. entPhysicalSerialNum.136 = TSP2022AAAB
  410. entPhysicalSerialNum.40 = TSP2022AABU
  411. entPhysicalSerialNum.208 = TSP2234AKPT
  412. entPhysicalSerialNum.192 = TSP2022AAAG
  413. entPhysicalSerialNum.720 = TSP2238AAAS
  414. entPhysicalSerialNum.288 = TSP2237ADMD
  415. entPhysicalSerialNum.384 = TSP2237ADMC
  416. entPhysicalModelName.1 = AIR-AP2802I-Z-K9
  417. entPhysicalModelName.8 = AIR-AP2802I-Z-K9
  418. entPhysicalModelName.448 = AIR-CAP2702I-Z-K9
  419. entPhysicalModelName.48 = AIR-CAP2702I-Z-K9
  420. entPhysicalModelName.504 = AIR-CAP2702I-Z-K9
  421. entPhysicalModelName.296 = AIR-CAP2702I-Z-K9
  422. entPhysicalModelName.336 = AIR-CAP2702I-Z-K9
  423. entPhysicalModelName.584 = AIR-CAP2702I-Z-K9
  424. entPhysicalModelName.24 = AIR-CAP2702I-Z-K9
  425. entPhysicalModelName.480 = AIR-CAP2702I-Z-K9
  426. entPhysicalModelName.128 = AIR-CAP2702I-Z-K9
  427. entPhysicalModelName.792 = AIR-CAP2702I-Z-K9
  428. entPhysicalModelName.768 = AIR-CAP2702I-Z-K9
  429. entPhysicalModelName.712 = AIR-CAP2702I-Z-K9
  430. entPhysicalModelName.496 = AIR-CAP2702I-Z-K9
  431. entPhysicalModelName.664 = AIR-CAP2702I-Z-K9
  432. entPhysicalModelName.376 = AIR-CAP2702I-Z-K9
  433. entPhysicalModelName.320 = AIR-CAP2702I-Z-K9
  434. entPhysicalModelName.640 = AIR-CAP2702I-Z-K9
  435. entPhysicalModelName.240 = AIR-CAP2702I-Z-K9
  436. entPhysicalModelName.168 = AIR-CAP2702I-Z-K9
  437. entPhysicalModelName.416 = AIR-CAP2702I-Z-K9
  438. entPhysicalModelName.632 = AIR-CAP2702E-Z-K9
  439. entPhysicalModelName.528 = AIR-CAP2702E-Z-K9
  440. entPhysicalModelName.256 = AIR-CAP2702E-Z-K9
  441. entPhysicalModelName.144 = AIR-CAP2702E-Z-K9
  442. entPhysicalModelName.216 = AIR-CAP2702E-Z-K9
  443. entPhysicalModelName.368 = AIR-CAP2702I-Z-K9
  444. entPhysicalModelName.248 = AIR-CAP2702E-Z-K9
  445. entPhysicalModelName.136 = AIR-CAP2702E-Z-K9
  446. entPhysicalModelName.40 = AIR-CAP2702E-Z-K9
  447. entPhysicalModelName.208 = AIR-CAP2702I-Z-K9
  448. entPhysicalModelName.192 = AIR-CAP2702E-Z-K9
  449. entPhysicalModelName.720 = AIR-CAP2702I-Z-K9
  450. entPhysicalModelName.288 = AIR-CAP2702I-Z-K9
  451. entPhysicalModelName.384 = AIR-CAP2702I-Z-K9  
  452.  
  453.  entAliasMappingIdentifierSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-MIB:IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entAliasMappingIdentifier'[0m]
  454. entAliasMappingIdentifier = No Such Instance currently exists at this OID  
  455.  
  456. Discover Inventory Item: 1, Cisco Aironet 2800 Series Mobility Express, , Mobility Express, AIR-AP2802I-Z-K9, TSP2405AAAU, 0, , -1, , V03, , 8.10.142.0, , , ,  
  457. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,1][0m 0.78ms]
  458.  
  459. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[1,"Cisco Aironet 2800 Series Mobility Express","","Mobility Express","AIR-AP2802I-Z-K9","TSP2405AAAU","0","","-1","","V03","","8.10.142.0","","","",null,3,1][0m 0.6ms]
  460.  
  461. Discover Inventory Item: 8, Cisco Aironet 2800 Series (IEEE 802.11ac) Access Point, , AP2800, AIR-AP2802I-Z-K9, TSP2405AAAU, 0, , -1, , V03, , 8.10.142.0, , , ,  
  462. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,8][0m 0.46ms]
  463.  
  464. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[8,"Cisco Aironet 2800 Series (IEEE 802.11ac) Access Point","","AP2800","AIR-AP2802I-Z-K9","TSP2405AAAU","0","","-1","","V03","","8.10.142.0","","","",null,3,8][0m 0.43ms]
  465.  
  466. Discover Inventory Item: 448, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234AKPP, 0, , -1, , V04, , 8.10.142.0, , , ,  
  467. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,448][0m 0.5ms]
  468.  
  469. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[448,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234AKPP","0","","-1","","V04","","8.10.142.0","","","",null,3,448][0m 0.54ms]
  470.  
  471. Discover Inventory Item: 48, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACDJ, 0, , -1, , V04, , 8.10.142.0, , , ,  
  472. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,48][0m 0.37ms]
  473.  
  474. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[48,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACDJ","0","","-1","","V04","","8.10.142.0","","","",null,3,48][0m 0.56ms]
  475.  
  476. Discover Inventory Item: 504, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACDG, 0, , -1, , V04, , 8.10.142.0, , , ,  
  477. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,504][0m 0.43ms]
  478.  
  479. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[504,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACDG","0","","-1","","V04","","8.10.142.0","","","",null,3,504][0m 0.42ms]
  480.  
  481. Discover Inventory Item: 296, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237AFSF, 0, , -1, , V04, , 8.10.142.0, , , ,  
  482. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,296][0m 0.43ms]
  483.  
  484. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[296,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237AFSF","0","","-1","","V04","","8.10.142.0","","","",null,3,296][0m 0.51ms]
  485.  
  486. Discover Inventory Item: 336, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ABLU, 0, , -1, , V04, , 8.10.142.0, , , ,  
  487. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,336][0m 0.36ms]
  488.  
  489. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[336,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ABLU","0","","-1","","V04","","8.10.142.0","","","",null,3,336][0m 0.5ms]
  490.  
  491. Discover Inventory Item: 584, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234ALCL, 0, , -1, , V04, , 8.10.142.0, , , ,  
  492. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,584][0m 0.37ms]
  493.  
  494. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[584,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234ALCL","0","","-1","","V04","","8.10.142.0","","","",null,3,584][0m 0.43ms]
  495.  
  496. Discover Inventory Item: 24, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ABKZ, 0, , -1, , V04, , 8.10.142.0, , , ,  
  497. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,24][0m 0.41ms]
  498.  
  499. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[24,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ABKZ","0","","-1","","V04","","8.10.142.0","","","",null,3,24][0m 0.44ms]
  500.  
  501. Discover Inventory Item: 480, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ABLB, 0, , -1, , V04, , 8.10.142.0, , , ,  
  502. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,480][0m 0.35ms]
  503.  
  504. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[480,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ABLB","0","","-1","","V04","","8.10.142.0","","","",null,3,480][0m 0.51ms]
  505.  
  506. Discover Inventory Item: 128, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237ADUU, 0, , -1, , V04, , 8.10.142.0, , , ,  
  507. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,128][0m 0.35ms]
  508.  
  509. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[128,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237ADUU","0","","-1","","V04","","8.10.142.0","","","",null,3,128][0m 0.58ms]
  510.  
  511. Discover Inventory Item: 792, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2238AABS, 0, , -1, , V04, , 8.10.142.0, , , ,  
  512. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,792][0m 0.42ms]
  513.  
  514. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[792,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2238AABS","0","","-1","","V04","","8.10.142.0","","","",null,3,792][0m 0.42ms]
  515.  
  516. Discover Inventory Item: 768, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ABKM, 0, , -1, , V04, , 8.10.142.0, , , ,  
  517. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,768][0m 0.39ms]
  518.  
  519. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[768,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ABKM","0","","-1","","V04","","8.10.142.0","","","",null,3,768][0m 0.87ms]
  520.  
  521. Discover Inventory Item: 712, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACDD, 0, , -1, , V04, , 8.10.142.0, , , ,  
  522. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,712][0m 0.38ms]
  523.  
  524. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[712,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACDD","0","","-1","","V04","","8.10.142.0","","","",null,3,712][0m 0.42ms]
  525.  
  526. Discover Inventory Item: 496, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234ALCP, 0, , -1, , V04, , 8.10.142.0, , , ,  
  527. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,496][0m 0.37ms]
  528.  
  529. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[496,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234ALCP","0","","-1","","V04","","8.10.142.0","","","",null,3,496][0m 0.42ms]
  530.  
  531. Discover Inventory Item: 664, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237AFSJ, 0, , -1, , V04, , 8.10.142.0, , , ,  
  532. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,664][0m 0.35ms]
  533.  
  534. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[664,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237AFSJ","0","","-1","","V04","","8.10.142.0","","","",null,3,664][0m 0.47ms]
  535.  
  536. Discover Inventory Item: 376, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234ALNM, 0, , -1, , V04, , 8.10.142.0, , , ,  
  537. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,376][0m 0.4ms]
  538.  
  539. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[376,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234ALNM","0","","-1","","V04","","8.10.142.0","","","",null,3,376][0m 0.44ms]
  540.  
  541. Discover Inventory Item: 320, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACCU, 0, , -1, , V04, , 8.10.142.0, , , ,  
  542. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,320][0m 0.34ms]
  543.  
  544. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[320,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACCU","0","","-1","","V04","","8.10.142.0","","","",null,3,320][0m 0.56ms]
  545.  
  546. Discover Inventory Item: 640, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234AHGF, 0, , -1, , V04, , 8.10.142.0, , , ,  
  547. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,640][0m 0.36ms]
  548.  
  549. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[640,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234AHGF","0","","-1","","V04","","8.10.142.0","","","",null,3,640][0m 0.43ms]
  550.  
  551. Discover Inventory Item: 240, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACDP, 0, , -1, , V04, , 8.10.142.0, , , ,  
  552. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,240][0m 0.39ms]
  553.  
  554. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[240,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACDP","0","","-1","","V04","","8.10.142.0","","","",null,3,240][0m 0.42ms]
  555.  
  556. Discover Inventory Item: 168, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2235ACFU, 0, , -1, , V04, , 8.10.142.0, , , ,  
  557. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,168][0m 0.35ms]
  558.  
  559. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[168,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2235ACFU","0","","-1","","V04","","8.10.142.0","","","",null,3,168][0m 0.39ms]
  560.  
  561. Discover Inventory Item: 416, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237ADMN, 0, , -1, , V04, , 8.10.142.0, , , ,  
  562. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,416][0m 0.38ms]
  563.  
  564. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[416,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237ADMN","0","","-1","","V04","","8.10.142.0","","","",null,3,416][0m 0.57ms]
  565.  
  566. Discover Inventory Item: 632, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAAA, 0, , -1, , V02, , 8.10.142.0, , , ,  
  567. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,632][0m 0.5ms]
  568.  
  569. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[632,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAAA","0","","-1","","V02","","8.10.142.0","","","",null,3,632][0m 0.57ms]
  570.  
  571. Discover Inventory Item: 528, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAKZ, 0, , -1, , V02, , 8.10.142.0, , , ,  
  572. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,528][0m 0.55ms]
  573.  
  574. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[528,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAKZ","0","","-1","","V02","","8.10.142.0","","","",null,3,528][0m 0.7ms]
  575.  
  576. Discover Inventory Item: 256, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AALD, 0, , -1, , V02, , 8.10.142.0, , , ,  
  577. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,256][0m 0.47ms]
  578.  
  579. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[256,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AALD","0","","-1","","V02","","8.10.142.0","","","",null,3,256][0m 0.65ms]
  580.  
  581. Discover Inventory Item: 144, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAKC, 0, , -1, , V02, , 8.10.142.0, , , ,  
  582. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,144][0m 0.41ms]
  583.  
  584. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[144,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAKC","0","","-1","","V02","","8.10.142.0","","","",null,3,144][0m 0.55ms]
  585.  
  586. Discover Inventory Item: 216, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAKT, 0, , -1, , V02, , 8.10.142.0, , , ,  
  587. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,216][0m 0.32ms]
  588.  
  589. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[216,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAKT","0","","-1","","V02","","8.10.142.0","","","",null,3,216][0m 0.47ms]
  590.  
  591. Discover Inventory Item: 368, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2238AACB, 0, , -1, , V04, , 8.10.142.0, , , ,  
  592. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,368][0m 0.39ms]
  593.  
  594. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[368,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2238AACB","0","","-1","","V04","","8.10.142.0","","","",null,3,368][0m 0.48ms]
  595.  
  596. Discover Inventory Item: 248, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AALC, 0, , -1, , V02, , 8.10.142.0, , , ,  
  597. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,248][0m 0.37ms]
  598.  
  599. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[248,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AALC","0","","-1","","V02","","8.10.142.0","","","",null,3,248][0m 0.36ms]
  600.  
  601. Discover Inventory Item: 136, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAAB, 0, , -1, , V02, , 8.10.142.0, , , ,  
  602. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,136][0m 0.3ms]
  603.  
  604. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[136,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAAB","0","","-1","","V02","","8.10.142.0","","","",null,3,136][0m 0.86ms]
  605.  
  606. Discover Inventory Item: 40, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AABU, 0, , -1, , V02, , 8.10.142.0, , , ,  
  607. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,40][0m 0.41ms]
  608.  
  609. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[40,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AABU","0","","-1","","V02","","8.10.142.0","","","",null,3,40][0m 0.35ms]
  610.  
  611. Discover Inventory Item: 208, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2234AKPT, 0, , -1, , V04, , 8.10.142.0, , , ,  
  612. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,208][0m 0.37ms]
  613.  
  614. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[208,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2234AKPT","0","","-1","","V04","","8.10.142.0","","","",null,3,208][0m 0.34ms]
  615.  
  616. Discover Inventory Item: 192, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702E-Z-K9, TSP2022AAAG, 0, , -1, , V02, , 8.10.142.0, , , ,  
  617. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,192][0m 1.45ms]
  618.  
  619. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[192,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702E-Z-K9","TSP2022AAAG","0","","-1","","V02","","8.10.142.0","","","",null,3,192][0m 0.37ms]
  620.  
  621. Discover Inventory Item: 720, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2238AAAS, 0, , -1, , V04, , 8.10.142.0, , , ,  
  622. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,720][0m 0.4ms]
  623.  
  624. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[720,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2238AAAS","0","","-1","","V04","","8.10.142.0","","","",null,3,720][0m 0.59ms]
  625.  
  626. Discover Inventory Item: 288, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237ADMD, 0, , -1, , V04, , 8.10.142.0, , , ,  
  627. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,288][0m 0.37ms]
  628.  
  629. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[288,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237ADMD","0","","-1","","V04","","8.10.142.0","","","",null,3,288][0m 0.33ms]
  630.  
  631. Discover Inventory Item: 384, Cisco Aironet 2700 Series (IEEE 802.11n) Access Point, , AP2700, AIR-CAP2702I-Z-K9, TSP2237ADMC, 0, , -1, , V04, , 8.10.142.0, , , ,  
  632. SQL[[1;33mSELECT COUNT(entPhysical_id) FROM `entPhysical` WHERE `device_id` = ? AND `entPhysicalIndex` = ? [0;33m[3,384][0m 0.27ms]
  633.  
  634. .SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=?,`ifIndex`=? WHERE `device_id`=? AND `entPhysicalIndex`=? [0;33m[384,"Cisco Aironet 2700 Series (IEEE 802.11n) Access Point","","AP2700","AIR-CAP2702I-Z-K9","TSP2237ADMC","0","","-1","","V04","","8.10.142.0","","","",null,3,384][0m 0.31ms]
  635.  
  636.  
  637. SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[3][0m 0.47ms]
  638.  
  639.  
  640. >> Runtime for discovery module 'entity-physical': 0.1310 seconds with 16088 bytes
  641. >> [0;36mSNMP[0m: [1/0.06s] [1;33mMySQL[0m: [73/0.34s] [0;32mRRD[0m: [0/0.00s]  
  642. #### Unload disco module entity-physical ####
  643.  
  644. Modules status: Global+  
  645. OS  
  646. Device  
  647.  
  648. #### Load disco module entity-state ####
  649. SQL[[1;33mSELECT entPhysical_id, entPhysicalIndex FROM entPhysical WHERE device_id=? [0;33m[3][0m 0.42ms]
  650.  
  651.  
  652. Entity States: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'ENTITY-STATE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entStateTable'[0m]
  653. entStateTable = No Such Object available on this agent at this OID  
  654.  
  655. SQL[[1;33mSELECT * FROM entityState WHERE device_id=? [0;33m[3][0m 0.62ms]
  656.  
  657.  
  658.  
  659. >> Runtime for discovery module 'entity-state': 0.0200 seconds with 1112 bytes
  660. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [2/0.01s] [0;32mRRD[0m: [0/0.00s]  
  661. #### Unload disco module entity-state ####
  662.  
  663. Modules status: Global+  
  664. OS  
  665. Device  
  666.  
  667. #### Load disco module isis ####
  668. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ISIS-MIB::isisCirc'[0m]
  669. isisCirc = No Such Object available on this agent at this OID  
  670.  
  671. Invalid snmp_walk() data = isisCirc = No Such Object available on this agent at this OID  
  672. SQL[[1;33mselect * from `isis_adjacencies` where `isis_adjacencies`.`device_id` = ? and `isis_adjacencies`.`device_id` is not null [0;33m[3][0m 0.5ms]
  673.  
  674.  
  675. >> Runtime for discovery module 'isis': 0.0290 seconds with 92280 bytes
  676. >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]  
  677. #### Unload disco module isis ####
  678.  
  679. Modules status: Global+  
  680. OS  
  681. Device  
  682.  
  683. #### Load disco module processors ####
  684. Caching data: os mempools processors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-Cc' '-Ih' '-m' 'AIRESPACE-SWITCHING-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'agentCurrentCPUUtilization'[0m]
  685. AIRESPACE-SWITCHING-MIB::agentCurrentCPUUtilization.0 = INTEGER: 7  
  686.  
  687.  
  688. YAML Discovery Data:  
  689. array (
  690.   'data' =>
  691.   array (
  692.     0 =>
  693.     array (
  694.       'oid' => 'agentCurrentCPUUtilization',
  695.       'num_oid' => '.1.3.6.1.4.1.14179.1.1.5.1.{{ $index }}',
  696.       'snmp_flags' =>
  697.       array (
  698.         0 => '-Cc',
  699.       ),
  700.     ),
  701.   ),
  702. )  
  703. Data agentCurrentCPUUtilization:  
  704. array (
  705.   0 =>
  706.   array (
  707.     'AIRESPACE-SWITCHING-MIB::agentCurrentCPUUtilization' => 'INTEGER: 7',
  708.   ),
  709. )  
  710.  
  711. Warning: preg_match() expects parameter 2 to be string, array given in /opt/librenms/LibreNMS/Device/Processor.php on line 239
  712. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.14179.1.1.5.1.0'[0m]
  713. 7  
  714.  
  715. Discovered LibreNMS\Device\Processor Array
  716. (
  717.     [processor_id] =>
  718.     [entPhysicalIndex] => 0
  719.     [hrDeviceIndex] => 0
  720.     [device_id] => 3
  721.     [processor_oid] => .1.3.6.1.4.1.14179.1.1.5.1.0
  722.     [processor_index] => 0
  723.     [processor_type] => ciscowlc
  724.     [processor_usage] => 7
  725.     [processor_descr] => Processor
  726.     [processor_precision] => 1
  727.     [processor_perc_warn] => 75
  728. )  
  729. SQL[[1;33mSELECT * FROM `processors` WHERE  device_id=? AND processor_index=? AND processor_type=? [0;33m[3,"0","ciscowlc"][0m 0.57ms]
  730.  
  731. .SQL[[1;33mSELECT * FROM `processors` WHERE  device_id=? AND processor_index=? AND processor_type=? [0;33m[3,"0","ciscowlc"][0m 0.35ms]
  732.  
  733. .SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? AND `processor_id` NOT IN (?,?) [0;33m[3,273,273][0m 0.23ms]
  734.  
  735. SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.56ms]
  736.  
  737.  
  738.  
  739. >> Runtime for discovery module 'processors': 0.0550 seconds with 179632 bytes
  740. >> [0;36mSNMP[0m: [2/0.05s] [1;33mMySQL[0m: [4/0.02s] [0;32mRRD[0m: [0/0.00s]  
  741. #### Unload disco module processors ####
  742.  
  743. Modules status: Global+  
  744. OS  
  745. Device  
  746.  
  747. #### Load disco module mempools ####
  748. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUb' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'AIRESPACE-SWITCHING-MIB::agentTotalMemory'[0m]
  749. AIRESPACE-SWITCHING-MIB::agentTotalMemory.0 = 1028260  
  750.  
  751. SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentTotalMemory"][0m 0.48ms]
  752.  
  753. SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentTotalMemory"][0m 0.29ms]
  754.  
  755. SQL[[1;33mupdate `cache` set `value` = ?, `expiration` = ? where `key` = ? [0;33m["s:26:\".1.3.6.1.4.1.14179.1.1.5.2\";",1644249026,"laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentTotalMemory"][0m 0.26ms]
  756.  
  757. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUb' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'AIRESPACE-SWITCHING-MIB::agentFreeMemory'[0m]
  758. AIRESPACE-SWITCHING-MIB::agentFreeMemory.0 = 213940  
  759.  
  760. SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentFreeMemory"][0m 0.56ms]
  761.  
  762. SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentFreeMemory"][0m 0.54ms]
  763.  
  764. SQL[[1;33mupdate `cache` set `value` = ?, `expiration` = ? where `key` = ? [0;33m["s:26:\".1.3.6.1.4.1.14179.1.1.5.3\";",1644249026,"laravel_cacheYamlDiscovery:oidToNumeric:AIRESPACE-SWITCHING-MIB\/AIRESPACE-SWITCHING-MIB::agentFreeMemory"][0m 0.27ms]
  765.  
  766. SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[3][0m 0.4ms]
  767.  
  768. SQL[[1;33mupdate `mempools` set `mempool_used` = ?, `mempool_free` = ? where `mempool_id` = ? [0;33m[833863680,219074560,155][0m 0.23ms]
  769.  
  770. Updated data:  
  771. array (
  772.   'mempool_used' => 833863680,
  773.   'mempool_free' => 219074560,
  774. )  
  775.  
  776. ciscowlc [system]: Memory: 79y5.23 MiB / 1004.16 MiB
  777.  
  778. >> Runtime for discovery module 'mempools': 0.0700 seconds with 333208 bytes
  779. >> [0;36mSNMP[0m: [2/0.06s] [1;33mMySQL[0m: [8/0.03s] [0;32mRRD[0m: [0/0.00s]  
  780. #### Unload disco module mempools ####
  781.  
  782. Modules status: Global+  
  783. OS+  
  784. Device  
  785.  
  786. #### Load disco module cisco-vrf-lite ####
  787. SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ?  [0;33m[3][0m 0.27ms]
  788.  
  789.  
  790. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1552 bytes
  791. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]  
  792. #### Unload disco module cisco-vrf-lite ####
  793.  
  794. Modules status: Global+  
  795. OS+  
  796. Device  
  797.  
  798. #### Load disco module cisco-mac-accounting ####
  799.  
  800. >> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds with 928 bytes
  801. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  802. #### Unload disco module cisco-mac-accounting ####
  803.  
  804. Modules status: Global+  
  805. OS+  
  806. Device  
  807.  
  808. #### Load disco module cisco-pw ####
  809.  
  810. >> Runtime for discovery module 'cisco-pw': 0.0000 seconds with 1480 bytes
  811. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  812. #### Unload disco module cisco-pw ####
  813.  
  814. Modules status: Global+  
  815. OS+  
  816. Device-  
  817. Module [ vrf ] disabled on host.
  818.  
  819. Modules status: Global+  
  820. OS+  
  821. Device  
  822.  
  823. #### Load disco module cisco-cef ####
  824. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'CISCO-CEF-MIB::cefSwitchingPath'[0m]
  825. cefSwitchingPath = No Such Object available on this agent at this OID  
  826.  
  827. cefSwitchingPath = No Such Object available on this agent at this OID || cefSwitchingPath ||  ||  ||
  828. array (
  829. )  
  830. Caching OIDs:  entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m]
  831. entPhysicalDescr.1 = Cisco Aironet 2800 Series Mobility Express
  832. entPhysicalDescr.8 = Cisco Aironet 2800 Series (IEEE 802.11ac) Access Point
  833. entPhysicalDescr.448 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  834. entPhysicalDescr.48 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  835. entPhysicalDescr.504 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  836. entPhysicalDescr.296 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  837. entPhysicalDescr.336 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  838. entPhysicalDescr.584 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  839. entPhysicalDescr.24 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  840. entPhysicalDescr.480 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  841. entPhysicalDescr.128 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  842. entPhysicalDescr.792 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  843. entPhysicalDescr.768 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  844. entPhysicalDescr.712 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  845. entPhysicalDescr.496 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  846. entPhysicalDescr.664 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  847. entPhysicalDescr.376 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  848. entPhysicalDescr.320 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  849. entPhysicalDescr.640 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  850. entPhysicalDescr.240 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  851. entPhysicalDescr.168 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  852. entPhysicalDescr.416 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  853. entPhysicalDescr.632 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  854. entPhysicalDescr.528 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  855. entPhysicalDescr.256 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  856. entPhysicalDescr.144 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  857. entPhysicalDescr.216 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  858. entPhysicalDescr.368 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  859. entPhysicalDescr.248 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  860. entPhysicalDescr.136 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  861. entPhysicalDescr.40 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  862. entPhysicalDescr.208 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  863. entPhysicalDescr.192 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  864. entPhysicalDescr.720 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  865. entPhysicalDescr.288 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point
  866. entPhysicalDescr.384 = Cisco Aironet 2700 Series (IEEE 802.11n) Access Point  
  867.  
  868.  entPhysicalNameSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhysicalName'[0m]
  869. entPhysicalName.1 = Mobility Express
  870. entPhysicalName.8 = AP2800
  871. entPhysicalName.448 = AP2700
  872. entPhysicalName.48 = AP2700
  873. entPhysicalName.504 = AP2700
  874. entPhysicalName.296 = AP2700
  875. entPhysicalName.336 = AP2700
  876. entPhysicalName.584 = AP2700
  877. entPhysicalName.24 = AP2700
  878. entPhysicalName.480 = AP2700
  879. entPhysicalName.128 = AP2700
  880. entPhysicalName.792 = AP2700
  881. entPhysicalName.768 = AP2700
  882. entPhysicalName.712 = AP2700
  883. entPhysicalName.496 = AP2700
  884. entPhysicalName.664 = AP2700
  885. entPhysicalName.376 = AP2700
  886. entPhysicalName.320 = AP2700
  887. entPhysicalName.640 = AP2700
  888. entPhysicalName.240 = AP2700
  889. entPhysicalName.168 = AP2700
  890. entPhysicalName.416 = AP2700
  891. entPhysicalName.632 = AP2700
  892. entPhysicalName.528 = AP2700
  893. entPhysicalName.256 = AP2700
  894. entPhysicalName.144 = AP2700
  895. entPhysicalName.216 = AP2700
  896. entPhysicalName.368 = AP2700
  897. entPhysicalName.248 = AP2700
  898. entPhysicalName.136 = AP2700
  899. entPhysicalName.40 = AP2700
  900. entPhysicalName.208 = AP2700
  901. entPhysicalName.192 = AP2700
  902. entPhysicalName.720 = AP2700
  903. entPhysicalName.288 = AP2700
  904. entPhysicalName.384 = AP2700  
  905.  
  906.  entPhysicalModelNameSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhysicalModelName'[0m]
  907. entPhysicalModelName.1 = AIR-AP2802I-Z-K9
  908. entPhysicalModelName.8 = AIR-AP2802I-Z-K9
  909. entPhysicalModelName.448 = AIR-CAP2702I-Z-K9
  910. entPhysicalModelName.48 = AIR-CAP2702I-Z-K9
  911. entPhysicalModelName.504 = AIR-CAP2702I-Z-K9
  912. entPhysicalModelName.296 = AIR-CAP2702I-Z-K9
  913. entPhysicalModelName.336 = AIR-CAP2702I-Z-K9
  914. entPhysicalModelName.584 = AIR-CAP2702I-Z-K9
  915. entPhysicalModelName.24 = AIR-CAP2702I-Z-K9
  916. entPhysicalModelName.480 = AIR-CAP2702I-Z-K9
  917. entPhysicalModelName.128 = AIR-CAP2702I-Z-K9
  918. entPhysicalModelName.792 = AIR-CAP2702I-Z-K9
  919. entPhysicalModelName.768 = AIR-CAP2702I-Z-K9
  920. entPhysicalModelName.712 = AIR-CAP2702I-Z-K9
  921. entPhysicalModelName.496 = AIR-CAP2702I-Z-K9
  922. entPhysicalModelName.664 = AIR-CAP2702I-Z-K9
  923. entPhysicalModelName.376 = AIR-CAP2702I-Z-K9
  924. entPhysicalModelName.320 = AIR-CAP2702I-Z-K9
  925. entPhysicalModelName.640 = AIR-CAP2702I-Z-K9
  926. entPhysicalModelName.240 = AIR-CAP2702I-Z-K9
  927. entPhysicalModelName.168 = AIR-CAP2702I-Z-K9
  928. entPhysicalModelName.416 = AIR-CAP2702I-Z-K9
  929. entPhysicalModelName.632 = AIR-CAP2702E-Z-K9
  930. entPhysicalModelName.528 = AIR-CAP2702E-Z-K9
  931. entPhysicalModelName.256 = AIR-CAP2702E-Z-K9
  932. entPhysicalModelName.144 = AIR-CAP2702E-Z-K9
  933. entPhysicalModelName.216 = AIR-CAP2702E-Z-K9
  934. entPhysicalModelName.368 = AIR-CAP2702I-Z-K9
  935. entPhysicalModelName.248 = AIR-CAP2702E-Z-K9
  936. entPhysicalModelName.136 = AIR-CAP2702E-Z-K9
  937. entPhysicalModelName.40 = AIR-CAP2702E-Z-K9
  938. entPhysicalModelName.208 = AIR-CAP2702I-Z-K9
  939. entPhysicalModelName.192 = AIR-CAP2702E-Z-K9
  940. entPhysicalModelName.720 = AIR-CAP2702I-Z-K9
  941. entPhysicalModelName.288 = AIR-CAP2702I-Z-K9
  942. entPhysicalModelName.384 = AIR-CAP2702I-Z-K9  
  943.  
  944.  
  945.  
  946. >> Runtime for discovery module 'cisco-cef': 0.0890 seconds with 61280 bytes
  947. >> [0;36mSNMP[0m: [3/0.07s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  948. #### Unload disco module cisco-cef ####
  949.  
  950. Modules status: Global+  
  951. OS+  
  952. Device+  
  953.  
  954. #### Load disco module slas ####
  955. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'CISCO-RTTMON-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'rttMonCtrl'[0m]
  956. rttMonCtrl = No Such Object available on this agent at this OID  
  957.  
  958. Invalid snmp_walk() data = rttMonCtrl = No Such Object available on this agent at this OID  
  959. SQL[[1;33mselect * from `slas` where `slas`.`device_id` = ? and `slas`.`device_id` is not null [0;33m[3][0m 0.44ms]
  960.  
  961.  
  962. >> Runtime for discovery module 'slas': 0.0400 seconds with 37672 bytes
  963. >> [0;36mSNMP[0m: [1/0.04s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]  
  964. #### Unload disco module slas ####
  965.  
  966. Modules status: Global+  
  967. OS  
  968. Device  
  969.  
  970. #### Load disco module cisco-cbqos ####
  971.  
  972. >> Runtime for discovery module 'cisco-cbqos': 0.0000 seconds with 2784 bytes
  973. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  974. #### Unload disco module cisco-cbqos ####
  975.  
  976. Modules status: Global+  
  977. OS+  
  978. Device  
  979.  
  980. #### Load disco module cisco-otv ####
  981.  
  982. >> Runtime for discovery module 'cisco-otv': 0.0000 seconds with 4224 bytes
  983. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  984. #### Unload disco module cisco-otv ####
  985.  
  986. Modules status: Global+  
  987. OS  
  988. Device  
  989.  
  990. #### Load disco module cisco-qfp ####
  991.  
  992. >> Runtime for discovery module 'cisco-qfp': 0.0000 seconds with 1144 bytes
  993. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  994. #### Unload disco module cisco-qfp ####
  995.  
  996. Modules status: Global+  
  997. OS  
  998. Device  
  999.  
  1000. #### Load disco module ipv4-addresses ####
  1001. SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[3][0m 0.39ms]
  1002.  
  1003. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m]
  1004. ipAdEntIfIndex.* 1
  1005. ipAdEntIfIndex.* 2  
  1006.  
  1007. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.66.23.80'[0m]
  1008. *  
  1009.  
  1010. SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[3,"1"][0m 0.55ms]
  1011.  
  1012. SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[3,"1"][0m 0.35ms]
  1013.  
  1014. SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.66.23.0\/24"][0m 0.29ms]
  1015.  
  1016. SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m["","10.66.23.0\/24"][0m 0.25ms]
  1017.  
  1018. sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.66.23.0\/24"][0m 0.58ms]
  1019.  
  1020. SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ?  [0;33m["10.66.23.80",24,44][0m 0.3ms]
  1021.  
  1022. SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["","10.66.23.80",24,44][0m 0.28ms]
  1023.  
  1024. .SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'ipAdEntNetMask.192.0.2.1'[0m]
  1025. *  
  1026.  
  1027. SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[3,"2"][0m 0.51ms]
  1028.  
  1029. !SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[3][0m 1.05ms]
  1030.  
  1031.  
  1032.  
  1033. >> Runtime for discovery module 'ipv4-addresses': 0.0780 seconds with 39384 bytes
  1034. >> [0;36mSNMP[0m: [3/0.07s] [1;33mMySQL[0m: [10/0.05s] [0;32mRRD[0m: [0/0.00s]  
  1035. #### Unload disco module ipv4-addresses ####
  1036.  
  1037. Modules status: Global-  
  1038. OS  
  1039. Device  
  1040. Module [ ipv6-addresses ] disabled globally.
  1041.  
  1042. Modules status: Global+  
  1043. OS  
  1044. Device  
  1045.  
  1046. #### Load disco module route ####
  1047. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'IP-FORWARD-MIB::inetCidrRouteNumber.0'[0m]
  1048. .*.*.6.0 No Such Object available on this agent at this OID  
  1049.  
  1050. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IP-FORWARD-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'inetCidrRouteNumber.0' 'ipCidrRouteNumber.0'[0m]
  1051. inetCidrRouteNumber.0 = No Such Object available on this agent at this OID
  1052. ipCidrRouteNumber.0 = No Such Object available on this agent at this OID  
  1053.  
  1054. SQL[[1;33mselect now() as now [0;33m[][0m 0.33ms]
  1055.  
  1056. SQL[[1;33mselect * from `route` where `device_id` = ? [0;33m[3][0m 2.73ms]
  1057.  
  1058. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'RFC1213-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.21'[0m]
  1059. ipRouteDest[*] = *
  1060. ipRouteDest[*] = *
  1061. ipRouteDest[*] = *
  1062. ipRouteIfIndex[*] = 2
  1063. ipRouteIfIndex[*] = 2
  1064. ipRouteIfIndex[*] = 2
  1065. ipRouteMetric1[*] = 0
  1066. ipRouteMetric1[*] = 0
  1067. ipRouteMetric1[*] = 0
  1068. ipRouteMetric2[*] = -1
  1069. ipRouteMetric2[*] = -1
  1070. ipRouteMetric2[*] = -1
  1071. ipRouteMetric3[*] = -1
  1072. ipRouteMetric3[*] = -1
  1073. ipRouteMetric3[*] = -1
  1074. ipRouteMetric4[*] = -1
  1075. ipRouteMetric4[*] = -1
  1076. ipRouteMetric4[*] = -1
  1077. ipRouteNextHop[*] = *
  1078. ipRouteNextHop[*] = *
  1079. ipRouteNextHop[*] = *
  1080. ipRouteType[*] = 3
  1081. ipRouteType[*] = 3
  1082. ipRouteType[*] = 3
  1083. ipRouteProto[*] = 1
  1084. ipRouteProto[*] = 1
  1085. ipRouteProto[*] = 1
  1086. ipRouteMask[*] = *
  1087. ipRouteMask[*] = *
  1088. ipRouteMask[*] = *
  1089. ipRouteMetric5[*] = -1
  1090. ipRouteMetric5[*] = -1
  1091. ipRouteMetric5[*] = -1
  1092. ipRouteInfo[*] = ccitt.0
  1093. ipRouteInfo[*] = ccitt.0
  1094. ipRouteInfo[*] = ccitt.0  
  1095.  
  1096. Routing table:  
  1097. array (
  1098.   '0.0.0.0' =>
  1099.   array (
  1100.     'ipRouteDest' => '0.0.0.0',
  1101.     'ipRouteIfIndex' => '2',
  1102.     'ipRouteMetric1' => '0',
  1103.     'ipRouteMetric2' => '-1',
  1104.     'ipRouteMetric3' => '-1',
  1105.     'ipRouteMetric4' => '-1',
  1106.     'ipRouteNextHop' => '0.0.0.0',
  1107.     'ipRouteType' => '3',
  1108.     'ipRouteProto' => '1',
  1109.     'ipRouteMask' => '0.0.0.0',
  1110.     'ipRouteMetric5' => '-1',
  1111.     'ipRouteInfo' => 'ccitt.0',
  1112.   ),
  1113.   '0.0.0.7' =>
  1114.   array (
  1115.     'ipRouteDest' => '7.0.0.0',
  1116.     'ipRouteIfIndex' => '2',
  1117.     'ipRouteMetric1' => '0',
  1118.     'ipRouteMetric2' => '-1',
  1119.     'ipRouteMetric3' => '-1',
  1120.     'ipRouteMetric4' => '-1',
  1121.     'ipRouteNextHop' => '0.0.0.0',
  1122.     'ipRouteType' => '3',
  1123.     'ipRouteProto' => '1',
  1124.     'ipRouteMask' => '255.255.255.0',
  1125.     'ipRouteMetric5' => '-1',
  1126.     'ipRouteInfo' => 'ccitt.0',
  1127.   ),
  1128.   '0.2.0.192' =>
  1129.   array (
  1130.     'ipRouteDest' => '192.0.2.0',
  1131.     'ipRouteIfIndex' => '2',
  1132.     'ipRouteMetric1' => '0',
  1133.     'ipRouteMetric2' => '-1',
  1134.     'ipRouteMetric3' => '-1',
  1135.     'ipRouteMetric4' => '-1',
  1136.     'ipRouteNextHop' => '0.0.0.0',
  1137.     'ipRouteType' => '3',
  1138.     'ipRouteProto' => '1',
  1139.     'ipRouteMask' => '255.255.255.0',
  1140.     'ipRouteMetric5' => '-1',
  1141.     'ipRouteInfo' => 'ccitt.0',
  1142.   ),
  1143. )  
  1144. RFC1213 SQL[[1;33mselect * from `devices` where `devices`.`device_id` = ? limit 1 [0;33m[3][0m 0.82ms]
  1145.  
  1146. SQL[[1;33mselect * from `ports` where `ports`.`device_id` = ? and `ports`.`device_id` is not null and `ifIndex` = ? limit 1 [0;33m[3,"2"][0m 0.6ms]
  1147.  
  1148. SQL[[1;33mselect * from `devices` where `devices`.`device_id` = ? limit 1 [0;33m[3][0m 0.41ms]
  1149.  
  1150. SQL[[1;33mselect * from `ports` where `ports`.`device_id` = ? and `ports`.`device_id` is not null and `ifIndex` = ? limit 1 [0;33m[3,"2"][0m 0.42ms]
  1151.  
  1152. SQL[[1;33mselect * from `devices` where `devices`.`device_id` = ? limit 1 [0;33m[3][0m 0.34ms]
  1153.  
  1154. SQL[[1;33mselect * from `ports` where `ports`.`device_id` = ? and `ports`.`device_id` is not null and `ifIndex` = ? limit 1 [0;33m[3,"2"][0m 0.39ms]
  1155.  
  1156. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'MPLS-L3VPN-STD-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'mplsL3VpnVrfPerfCurrNumRoutes'[0m]
  1157. mplsL3VpnVrfPerfCurrNumRoutes = No Such Object available on this agent at this OID  
  1158.  
  1159. mplsL3VpnVrfRteTable SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'MPLS-L3VPN-STD-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'mplsL3VpnVrfRteTable'[0m]
  1160. mplsL3VpnVrfRteTable = No Such Object available on this agent at this OID  
  1161.  
  1162.  
  1163. Processing: SQL[[1;33mDELETE FROM `route` WHERE `route_id` = ? [0;33m[26868][0m 0.5ms]
  1164.  
  1165. -array (
  1166.   'route_id' => 26868,
  1167.   'created_at' => '2022-02-07 12:19:12',
  1168.   'updated_at' => '2022-02-07 12:19:12',
  1169.   'device_id' => 3,
  1170.   'port_id' => 0,
  1171.   'context_name' => '',
  1172.   'inetCidrRouteIfIndex' => 2,
  1173.   'inetCidrRouteType' => 3,
  1174.   'inetCidrRouteProto' => 1,
  1175.   'inetCidrRouteNextHopAS' => 0,
  1176.   'inetCidrRouteMetric1' => 0,
  1177.   'inetCidrRouteDestType' => 'ipv4',
  1178.   'inetCidrRouteDest' => '0.0.0.0',
  1179.   'inetCidrRouteNextHopType' => 'ipv4',
  1180.   'inetCidrRouteNextHop' => '0.0.0.0',
  1181.   'inetCidrRoutePolicy' => 'ccitt.0',
  1182.   'inetCidrRoutePfxLen' => 0,
  1183. )  
  1184. SQL[[1;33mDELETE FROM `route` WHERE `route_id` = ? [0;33m[26869][0m 0.3ms]
  1185.  
  1186. -array (
  1187.   'route_id' => 26869,
  1188.   'created_at' => '2022-02-07 12:19:12',
  1189.   'updated_at' => '2022-02-07 12:19:12',
  1190.   'device_id' => 3,
  1191.   'port_id' => 0,
  1192.   'context_name' => '',
  1193.   'inetCidrRouteIfIndex' => 2,
  1194.   'inetCidrRouteType' => 3,
  1195.   'inetCidrRouteProto' => 1,
  1196.   'inetCidrRouteNextHopAS' => 0,
  1197.   'inetCidrRouteMetric1' => 0,
  1198.   'inetCidrRouteDestType' => 'ipv4',
  1199.   'inetCidrRouteDest' => '7.0.0.0',
  1200.   'inetCidrRouteNextHopType' => 'ipv4',
  1201.   'inetCidrRouteNextHop' => '0.0.0.0',
  1202.   'inetCidrRoutePolicy' => 'ccitt.0',
  1203.   'inetCidrRoutePfxLen' => 24,
  1204. )  
  1205. SQL[[1;33mDELETE FROM `route` WHERE `route_id` = ? [0;33m[26870][0m 0.24ms]
  1206.  
  1207. -array (
  1208.   'route_id' => 26870,
  1209.   'created_at' => '2022-02-07 12:19:12',
  1210.   'updated_at' => '2022-02-07 12:19:12',
  1211.   'device_id' => 3,
  1212.   'port_id' => 0,
  1213.   'context_name' => '',
  1214.   'inetCidrRouteIfIndex' => 2,
  1215.   'inetCidrRouteType' => 3,
  1216.   'inetCidrRouteProto' => 1,
  1217.   'inetCidrRouteNextHopAS' => 0,
  1218.   'inetCidrRouteMetric1' => 0,
  1219.   'inetCidrRouteDestType' => 'ipv4',
  1220.   'inetCidrRouteDest' => '192.0.2.0',
  1221.   'inetCidrRouteNextHopType' => 'ipv4',
  1222.   'inetCidrRouteNextHop' => '0.0.0.0',
  1223.   'inetCidrRoutePolicy' => 'ccitt.0',
  1224.   'inetCidrRoutePfxLen' => 24,
  1225. )  
  1226. SQL[[1;33mINSERT IGNORE INTO `route` (`inetCidrRouteDestType`,`inetCidrRouteDest`,`inetCidrRoutePfxLen`,`inetCidrRoutePolicy`,`inetCidrRouteNextHopType`,`inetCidrRouteNextHop`,`inetCidrRouteMetric1`,`inetCidrRouteNextHopAS`,`inetCidrRouteProto`,`inetCidrRouteType`,`inetCidrRouteIfIndex`,`context_name`,`device_id`,`port_id`,`updated_at`,`created_at`)  VALUES (:inetCidrRouteDestType,:inetCidrRouteDest,:inetCidrRoutePfxLen,:inetCidrRoutePolicy,:inetCidrRouteNextHopType,:inetCidrRouteNextHop,:inetCidrRouteMetric1,:inetCidrRouteNextHopAS,:inetCidrRouteProto,:inetCidrRouteType,:inetCidrRouteIfIndex,:context_name,:device_id,:port_id,:updated_at,:created_at) [0;33m{"inetCidrRouteDestType":"ipv4","inetCidrRouteDest":"0.0.0.0","inetCidrRoutePfxLen":0,"inetCidrRoutePolicy":"ccitt.0","inetCidrRouteNextHopType":"ipv4","inetCidrRouteNextHop":"0.0.0.0","inetCidrRouteMetric1":"0","inetCidrRouteNextHopAS":"0","inetCidrRouteProto":"1","inetCidrRouteType":"3","inetCidrRouteIfIndex":"2","context_name":"","device_id":3,"port_id":null,"updated_at":"2022-02-07 12:20:26","created_at":"2022-02-07 12:20:26"}[0m 0.32ms]
  1227.  
  1228. +SQL[[1;33mINSERT IGNORE INTO `route` (`inetCidrRouteDestType`,`inetCidrRouteDest`,`inetCidrRoutePfxLen`,`inetCidrRoutePolicy`,`inetCidrRouteNextHopType`,`inetCidrRouteNextHop`,`inetCidrRouteMetric1`,`inetCidrRouteNextHopAS`,`inetCidrRouteProto`,`inetCidrRouteType`,`inetCidrRouteIfIndex`,`context_name`,`device_id`,`port_id`,`updated_at`,`created_at`)  VALUES (:inetCidrRouteDestType,:inetCidrRouteDest,:inetCidrRoutePfxLen,:inetCidrRoutePolicy,:inetCidrRouteNextHopType,:inetCidrRouteNextHop,:inetCidrRouteMetric1,:inetCidrRouteNextHopAS,:inetCidrRouteProto,:inetCidrRouteType,:inetCidrRouteIfIndex,:context_name,:device_id,:port_id,:updated_at,:created_at) [0;33m{"inetCidrRouteDestType":"ipv4","inetCidrRouteDest":"7.0.0.0","inetCidrRoutePfxLen":24,"inetCidrRoutePolicy":"ccitt.0","inetCidrRouteNextHopType":"ipv4","inetCidrRouteNextHop":"0.0.0.0","inetCidrRouteMetric1":"0","inetCidrRouteNextHopAS":"0","inetCidrRouteProto":"1","inetCidrRouteType":"3","inetCidrRouteIfIndex":"2","context_name":"","device_id":3,"port_id":null,"updated_at":"2022-02-07 12:20:26","created_at":"2022-02-07 12:20:26"}[0m 0.72ms]
  1229.  
  1230. +SQL[[1;33mINSERT IGNORE INTO `route` (`inetCidrRouteDestType`,`inetCidrRouteDest`,`inetCidrRoutePfxLen`,`inetCidrRoutePolicy`,`inetCidrRouteNextHopType`,`inetCidrRouteNextHop`,`inetCidrRouteMetric1`,`inetCidrRouteNextHopAS`,`inetCidrRouteProto`,`inetCidrRouteType`,`inetCidrRouteIfIndex`,`context_name`,`device_id`,`port_id`,`updated_at`,`created_at`)  VALUES (:inetCidrRouteDestType,:inetCidrRouteDest,:inetCidrRoutePfxLen,:inetCidrRoutePolicy,:inetCidrRouteNextHopType,:inetCidrRouteNextHop,:inetCidrRouteMetric1,:inetCidrRouteNextHopAS,:inetCidrRouteProto,:inetCidrRouteType,:inetCidrRouteIfIndex,:context_name,:device_id,:port_id,:updated_at,:created_at) [0;33m{"inetCidrRouteDestType":"ipv4","inetCidrRouteDest":"192.0.2.0","inetCidrRoutePfxLen":24,"inetCidrRoutePolicy":"ccitt.0","inetCidrRouteNextHopType":"ipv4","inetCidrRouteNextHop":"0.0.0.0","inetCidrRouteMetric1":"0","inetCidrRouteNextHopAS":"0","inetCidrRouteProto":"1","inetCidrRouteType":"3","inetCidrRouteIfIndex":"2","context_name":"","device_id":3,"port_id":null,"updated_at":"2022-02-07 12:20:26","created_at":"2022-02-07 12:20:26"}[0m 0.31ms]
  1231.  
  1232. +
  1233. >> Runtime for discovery module 'route': 0.1380 seconds with 107384 bytes
  1234. >> [0;36mSNMP[0m: [2/0.04s] [1;33mMySQL[0m: [14/0.08s] [0;32mRRD[0m: [0/0.00s]  
  1235. #### Unload disco module route ####
  1236.  
  1237. Modules status: Global+  
  1238. OS  
  1239. Device  
  1240.  
  1241. #### Load disco module sensors ####
  1242.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entPhySensorTypeSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhySensorType'[0m]
  1243. entPhySensorType = No Such Object available on this agent at this OID  
  1244.  
  1245. Invalid snmp_walk() data = entPhySensorType = No Such Object available on this agent at this OID  
  1246.  entPhySensorScaleSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhySensorScale'[0m]
  1247. entPhySensorScale = No Such Object available on this agent at this OID  
  1248.  
  1249. Invalid snmp_walk() data = entPhySensorScale = No Such Object available on this agent at this OID  
  1250.  entPhySensorPrecisionSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhySensorPrecision'[0m]
  1251. entPhySensorPrecision = No Such Object available on this agent at this OID  
  1252.  
  1253. Invalid snmp_walk() data = entPhySensorPrecision = No Such Object available on this agent at this OID  
  1254.  entPhySensorValueSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhySensorValue'[0m]
  1255. entPhySensorValue = No Such Object available on this agent at this OID  
  1256.  
  1257. Invalid snmp_walk() data = entPhySensorValue = No Such Object available on this agent at this OID  
  1258.  entPhySensorOperStatusSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'ENTITY-SENSOR-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'entPhySensorOperStatus'[0m]
  1259. entPhySensorOperStatus = No Such Object available on this agent at this OID  
  1260.  
  1261. Invalid snmp_walk() data = entPhySensorOperStatus = No Such Object available on this agent at this OID  
  1262.  
  1263. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",3,"ipmi"][0m 1.57ms]
  1264.  
  1265. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",3,"ipmi"][0m 1.3ms]
  1266.  
  1267. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",3,"ipmi"][0m 0.79ms]
  1268.  
  1269. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",3,"ipmi"][0m 0.73ms]
  1270.  
  1271. Airflow: array (
  1272. )  
  1273. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",3,"snmp"][0m 0.59ms]
  1274.  
  1275.  
  1276. Current: array (
  1277. )  
  1278. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",3,"snmp"][0m 0.58ms]
  1279.  
  1280.  
  1281. Charge: array (
  1282. )  
  1283. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",3,"snmp"][0m 0.67ms]
  1284.  
  1285.  
  1286. Dbm: array (
  1287. )  
  1288. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",3,"snmp"][0m 0.6ms]
  1289.  
  1290.  
  1291. Fanspeed: array (
  1292. )  
  1293. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",3,"snmp"][0m 0.56ms]
  1294.  
  1295.  
  1296. Frequency: array (
  1297. )  
  1298. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",3,"snmp"][0m 0.57ms]
  1299.  
  1300.  
  1301. Humidity: array (
  1302. )  
  1303. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",3,"snmp"][0m 0.55ms]
  1304.  
  1305.  
  1306. Load: array (
  1307. )  
  1308. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",3,"snmp"][0m 0.88ms]
  1309.  
  1310.  
  1311. Loss: array (
  1312. )  
  1313. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",3,"snmp"][0m 0.56ms]
  1314.  
  1315.  
  1316. Power: array (
  1317. )  
  1318. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",3,"snmp"][0m 0.55ms]
  1319.  
  1320.  
  1321. Power_consumed: array (
  1322. )  
  1323. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",3,"snmp"][0m 0.67ms]
  1324.  
  1325.  
  1326. Power_factor: array (
  1327. )  
  1328. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",3,"snmp"][0m 0.56ms]
  1329.  
  1330.  
  1331. Runtime: array (
  1332. )  
  1333. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",3,"snmp"][0m 0.6ms]
  1334.  
  1335.  
  1336. Signal: array (
  1337. )  
  1338. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",3,"snmp"][0m 0.58ms]
  1339.  
  1340.  
  1341. State: array (
  1342. )  
  1343. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",3,"snmp"][0m 0.6ms]
  1344.  
  1345.  
  1346. Count: array (
  1347. )  
  1348. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",3,"snmp"][0m 0.57ms]
  1349.  
  1350.  
  1351. Temperature:  AIRESPACE temperature SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'AIRESPACE-WIRELESS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bsnSensorTemperature'[0m]
  1352. bsnSensorTemperature.0 = 5000  
  1353.  
  1354. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'AIRESPACE-WIRELESS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bsnTemperatureAlarmLowLimit'[0m]
  1355. bsnTemperatureAlarmLowLimit.0 = 0  
  1356.  
  1357. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'AIRESPACE-WIRELESS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bsnTemperatureAlarmHighLimit'[0m]
  1358. bsnTemperatureAlarmHighLimit.0 = 0  
  1359.  
  1360.  Unit Temperature 0, Discover sensor: .1.3.6.1.4.1.14179.2.3.1.13.0, 0, wlc, Unit Temperature 0, snmp, 1, 1, 0, 5000, (limits: LL: , LW: 0, W: 0, H: )  
  1361. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",3,"wlc","0"][0m 0.83ms]
  1362.  
  1363. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",3,"wlc","0"][0m 0.49ms]
  1364.  
  1365. .array (
  1366.   'wlc' =>
  1367.   array (
  1368.     0 => 1,
  1369.   ),
  1370. )  
  1371. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",3,"snmp"][0m 0.61ms]
  1372.  
  1373. 0 -> wlc  
  1374.  
  1375. Tv_signal: array (
  1376. )  
  1377. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",3,"snmp"][0m 0.48ms]
  1378.  
  1379.  
  1380. Bitrate: array (
  1381. )  
  1382. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["bitrate",3,"snmp"][0m 0.54ms]
  1383.  
  1384.  
  1385. Voltage: array (
  1386. )  
  1387. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",3,"snmp"][0m 0.55ms]
  1388.  
  1389.  
  1390. Snr: array (
  1391. )  
  1392. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",3,"snmp"][0m 0.47ms]
  1393.  
  1394.  
  1395. Pressure: array (
  1396. )  
  1397. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",3,"snmp"][0m 0.45ms]
  1398.  
  1399.  
  1400. Cooling: array (
  1401. )  
  1402. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",3,"snmp"][0m 0.45ms]
  1403.  
  1404.  
  1405. Delay: array (
  1406. )  
  1407. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",3,"snmp"][0m 0.63ms]
  1408.  
  1409.  
  1410. Quality_factor: array (
  1411. )  
  1412. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",3,"snmp"][0m 0.66ms]
  1413.  
  1414.  
  1415. Chromatic_dispersion: array (
  1416. )  
  1417. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",3,"snmp"][0m 0.65ms]
  1418.  
  1419.  
  1420. Ber: array (
  1421. )  
  1422. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",3,"snmp"][0m 0.63ms]
  1423.  
  1424.  
  1425. Eer: array (
  1426. )  
  1427. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",3,"snmp"][0m 0.65ms]
  1428.  
  1429.  
  1430. Waterflow: array (
  1431. )  
  1432. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",3,"snmp"][0m 0.63ms]
  1433.  
  1434.  
  1435. Percent: array (
  1436. )  
  1437. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",3,"snmp"][0m 0.63ms]
  1438.  
  1439.  
  1440.  
  1441. >> Runtime for discovery module 'sensors': 0.2590 seconds with 13552 bytes
  1442. >> [0;36mSNMP[0m: [8/0.22s] [1;33mMySQL[0m: [36/0.23s] [0;32mRRD[0m: [0/0.00s]  
  1443. #### Unload disco module sensors ####
  1444.  
  1445. Modules status: Global+  
  1446. OS  
  1447. Device  
  1448.  
  1449. #### Load disco module storage ####
  1450. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'aixFsTableEntry'[0m]
  1451. Exitcode: 1  
  1452. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1453. Cannot find module (IBM-AIX-MIB): At line 15 in (none)
  1454. aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)  
  1455.  
  1456. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1457. Cannot find module (IBM-AIX-MIB): At line 15 in (none)
  1458. aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)  
  1459. aix_filesystem : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m]
  1460. fileSystemSpaceTable = No more variables left in this MIB View (It is past the end of the MIB tree)  
  1461.  
  1462. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'datasetTable'[0m]
  1463. Exitcode: 1  
  1464. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1465. Cannot find module (FREENAS-MIB): At line 15 in (none)
  1466. datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)  
  1467.  
  1468. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1469. Cannot find module (FREENAS-MIB): At line 15 in (none)
  1470. datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)  
  1471. SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '3' AND `storage_type` != 'dataset' [0;33m[][0m 0.53ms]
  1472.  
  1473. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'zpoolTable'[0m]
  1474. Exitcode: 1  
  1475. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1476. Cannot find module (FREENAS-MIB): At line 15 in (none)
  1477. zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)  
  1478.  
  1479. MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/cisco
  1480. Cannot find module (FREENAS-MIB): At line 15 in (none)
  1481. zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)  
  1482. SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '3' AND `storage_type` != 'zpool' [0;33m[][0m 0.58ms]
  1483.  
  1484. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'hrStorageTable'[0m]
  1485. hrStorageTable = No Such Object available on this agent at this OID  
  1486.  
  1487. hrStorage : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'dskTable'[0m]
  1488. dskTable = No Such Object available on this agent at this OID  
  1489.  
  1490. Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID  
  1491. SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '3' AND `storage_type` != 'dsk' [0;33m[][0m 0.72ms]
  1492.  
  1493.  
  1494. SQL[[1;33mSELECT * FROM `storage` WHERE `device_id`  = '3' [0;33m[][0m 0.4ms]
  1495.  
  1496.  
  1497.  
  1498. >> Runtime for discovery module 'storage': 0.1220 seconds with 15112 bytes
  1499. >> [0;36mSNMP[0m: [5/0.09s] [1;33mMySQL[0m: [4/0.02s] [0;32mRRD[0m: [0/0.00s]  
  1500. #### Unload disco module storage ####
  1501.  
  1502. Modules status: Global+  
  1503. OS  
  1504. Device  
  1505.  
  1506. #### Load disco module hr-device ####
  1507.  
  1508. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m]
  1509. hrDeviceEntry = No Such Object available on this agent at this OID  
  1510.  
  1511. Invalid snmp_walk() data = hrDeviceEntry = No Such Object available on this agent at this OID  
  1512. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m]
  1513. hrProcessorEntry = No Such Object available on this agent at this OID  
  1514.  
  1515. Invalid snmp_walk() data = hrProcessorEntry = No Such Object available on this agent at this OID  
  1516. array (
  1517. )  
  1518. SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '3' [0;33m[][0m 0.57ms]
  1519.  
  1520.  
  1521.  
  1522. >> Runtime for discovery module 'hr-device': 0.0420 seconds with 1448 bytes
  1523. >> [0;36mSNMP[0m: [2/0.04s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]  
  1524. #### Unload disco module hr-device ####
  1525.  
  1526. Modules status: Global+  
  1527. OS  
  1528. Device  
  1529.  
  1530. #### Load disco module discovery-protocols ####
  1531.  CISCO-CDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'cdpCache'[0m]
  1532. cdpCacheAddressType[1][2] = 1
  1533. cdpCacheAddress[1][2] = "0A 42 21 1A "
  1534. cdpCacheVersion[1][2] = Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(7)E4, RELEASE SOFTWARE (fc2)
  1535. Technical Support: http://www.cisco.com/techsupport
  1536. Copyright (c) 1986-2021 by Cisco Systems, Inc.
  1537. Compiled Mon 08-Mar-21 11:26 by prod_rel_team
  1538. cdpCacheDeviceId[1][2] = BRSAOSW99003.sika.com
  1539. cdpCacheDevicePort[1][2] = GigabitEthernet1/0/37
  1540. cdpCachePlatform[1][2] = cisco WS-C2960X-48LPD-L
  1541. cdpCacheCapabilities[1][2] = "28 00 00 00 "
  1542. cdpCacheNativeVLAN[1][2] = 0
  1543. cdpCacheDuplex[1][2] = 3
  1544. cdpCtAddressType[1][2][1] = 1
  1545. cdpCtAddress[1][2][1] = "0A 42 21 1A "  
  1546.  
  1547. SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[3,1][0m 0.84ms]
  1548.  
  1549. array (
  1550.   'cdpCacheAddressType' => '1',
  1551.   'cdpCacheAddress' => '0A 42 21 1A',
  1552.   'cdpCacheVersion' => 'Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(7)E4, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport
  1553. Copyright (c) 1986-2021 by Cisco Systems, Inc.
  1554. Compiled Mon 08-Mar-21 11:26 by prod_rel_team',
  1555.   'cdpCacheDeviceId' => 'BRSAOSW99003.sika.com',
  1556.   'cdpCacheDevicePort' => 'GigabitEthernet1/0/37',
  1557.   'cdpCachePlatform' => 'cisco WS-C2960X-48LPD-L',
  1558.   'cdpCacheCapabilities' => '28 00 00 00',
  1559.   'cdpCacheNativeVLAN' => '0',
  1560.   'cdpCacheDuplex' => '3',
  1561.   'cdpCtAddressType' =>
  1562.   array (
  1563.     1 => '1',
  1564.   ),
  1565.   'cdpCtAddress' =>
  1566.   array (
  1567.     1 => '0A 42 21 1A',
  1568.   ),
  1569. )  
  1570. SQL[[1;33mSELECT `device_id` FROM `devices` WHERE `hostname`=? OR `hostname`=? OR concat(`hostname`, '.', ?) =? OR `hostname`=? OR `ip`=? [0;33m["BRSAOSW99003.sika.com","BRSAOSW99003.sika.com.sika.com","sika.com","BRSAOSW99003.sika.com",{"ip":"10.66.33.26","cidr":32,"host_bits":32},"\nB!\u001a"][0m 0.69ms]
  1571.  
  1572. SQL[[1;33mSELECT `device_id` FROM `devices` WHERE `sysName`=? OR `sysName`=? OR concat(`sysName`, '.', ?) =? LIMIT 2 [0;33m["BRSAOSW99003.sika.com","BRSAOSW99003.sika.com.sika.com","sika.com","BRSAOSW99003.sika.com"][0m 0.53ms]
  1573.  
  1574. SQL[[1;33mSELECT * FROM (SELECT `port_id` FROM `ports` WHERE `device_id`=? AND (`ifDescr`=? OR `ifName`=?) UNION SELECT `port_id` FROM `ports` WHERE `device_id`=? AND `ifAlias`=? LIMIT 1) p [0;33m[14,"GigabitEthernet1\/0\/37","GigabitEthernet1\/0\/37",14,"GigabitEthernet1\/0\/37"][0m 0.76ms]
  1575.  
  1576. Discover link: 44, cdp, 377, BRSAOSW99003.sika.com, GigabitEthernet1/0/37, cisco WS-C2960X-48LPD-L, Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(7)E4, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport
  1577. Copyright (c) 1986-2021 by Cisco Systems, Inc.
  1578. Compiled Mon 08-Mar-21 11:26 by prod_rel_team, 14  
  1579. SQL[[1;33mSELECT COUNT(*) FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["BRSAOSW99003.sika.com",44,"cdp","GigabitEthernet1\/0\/37"][0m 0.36ms]
  1580.  
  1581. SQL[[1;33mSELECT `id`,`local_device_id`,`remote_platform`,`remote_version`,`remote_device_id`,`remote_port_id` FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["BRSAOSW99003.sika.com",44,"cdp","GigabitEthernet1\/0\/37"][0m 0.42ms]
  1582.  
  1583. .
  1584.  LLDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'lldpRemTable'[0m]
  1585. lldpRemTable = No Such Object available on this agent at this OID  
  1586.  
  1587.  
  1588.  OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[3][0m 0.58ms]
  1589.  
  1590.  
  1591. array (
  1592.   44 =>
  1593.   array (
  1594.     'BRSAOSW99003.sika.com' =>
  1595.     array (
  1596.       'GigabitEthernet1/0/37' => 1,
  1597.     ),
  1598.   ),
  1599. )  
  1600. SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[3][0m 1.05ms]
  1601.  
  1602. 44 -> BRSAOSW99003.sika.com -> GigabitEthernet1/0/37  
  1603. SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.47ms]
  1604.  
  1605.  0 orphaned links deleted  
  1606.  
  1607. >> Runtime for discovery module 'discovery-protocols': 0.0880 seconds with 44568 bytes
  1608. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [9/0.06s] [0;32mRRD[0m: [0/0.00s]  
  1609. #### Unload disco module discovery-protocols ####
  1610.  
  1611. Modules status: Global+  
  1612. OS  
  1613. Device  
  1614.  
  1615. #### Load disco module arp-table ####
  1616. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress'[0m]  
  1617. IP-MIB::ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  1618.  
  1619.  
  1620. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress'[0m]  
  1621. IP-MIB::ipNetToMediaPhysAddress = No Such Instance currently exists at this OID
  1622.  
  1623.  
  1624. SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[3,""][0m 1.87ms]
  1625.  
  1626. SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 3.14ms]
  1627.  
  1628.  
  1629.  
  1630. >> Runtime for discovery module 'arp-table': 0.0510 seconds with -10912 bytes
  1631. >> [0;36mSNMP[0m: [2/0.04s] [1;33mMySQL[0m: [2/0.05s] [0;32mRRD[0m: [0/0.00s]  
  1632. #### Unload disco module arp-table ####
  1633.  
  1634. Modules status: Global+  
  1635. OS  
  1636. Device  
  1637.  
  1638. #### Load disco module discovery-arp ####
  1639. SQL[[1;33m
  1640.     SELECT *
  1641.     FROM ipv4_mac as m, ports as i
  1642.     WHERE m.port_id = i.port_id
  1643.     AND i.device_id = ?
  1644.     AND i.deleted = 0
  1645.     AND NOT EXISTS (
  1646.         SELECT * FROM ipv4_addresses a
  1647.         WHERE a.ipv4_address = m.ipv4_address
  1648.     )
  1649.     GROUP BY ipv4_address
  1650.     ORDER BY ipv4_address
  1651.      [0;33m[3][0m 1.52ms]
  1652.  
  1653.  
  1654.  
  1655. >> Runtime for discovery module 'discovery-arp': 0.0020 seconds with 896 bytes
  1656. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]  
  1657. #### Unload disco module discovery-arp ####
  1658.  
  1659. Modules status: Global-  
  1660. OS  
  1661. Device  
  1662. Module [ junose-atm-vp ] disabled globally.
  1663.  
  1664. Modules status: Global+  
  1665. OS  
  1666. Device  
  1667.  
  1668. #### Load disco module bgp-peers ####
  1669. SNMP[[0;36m'/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m]
  1670. "A0 B4 39 3F 84 80 "  
  1671.  
  1672. No BGP on hostPeers :  
  1673. SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[3,""][0m 0.61ms]
  1674.  
  1675. SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[3,""][0m 0.48ms]
  1676.  
  1677.  
  1678. SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[3][0m 1ms]
  1679.  
  1680.  
  1681. >> Runtime for discovery module 'bgp-peers': 0.0240 seconds with 3600 bytes
  1682. >> [0;36mSNMP[0m: [1/0.02s] [1;33mMySQL[0m: [3/0.02s] [0;32mRRD[0m: [0/0.00s]  
  1683. #### Unload disco module bgp-peers ####
  1684.  
  1685. Modules status: Global+  
  1686. OS  
  1687. Device  
  1688.  
  1689. #### Load disco module vlans ####
  1690. SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[3][0m 0.63ms]
  1691.  
  1692. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m]
  1693. dot1dBasePortIfIndex.1 = 1  
  1694.  
  1695. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m]
  1696. version1  
  1697.  
  1698. ver version1 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'Q-BRIDGE-MIB::dot1qVlanCurrentUntaggedPorts'[0m]  
  1699. Q-BRIDGE-MIB::dot1qVlanCurrentUntaggedPorts[0][1] = "FF FF FF "
  1700.  
  1701.  
  1702. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'Q-BRIDGE-MIB::dot1qVlanCurrentEgressPorts'[0m]  
  1703. Q-BRIDGE-MIB::dot1qVlanCurrentEgressPorts[0][1] = "80 00 00 "
  1704.  
  1705.  
  1706. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'Q-BRIDGE-MIB::dot1qVlanStaticName'[0m]  
  1707. Q-BRIDGE-MIB::dot1qVlanStaticName[1] = Default
  1708.  
  1709.  
  1710. Processing vlan ID: 1  
  1711. SQL[[1;33mselect * from `vlans` where (`device_id` = ? and `vlan_vlan` = ?) limit 1 [0;33m[3,1][0m 0.69ms]
  1712.  
  1713.  
  1714. VLAN 1
  1715. dot1d id  ifIndex   Port Name                Priority  State          Cost      
  1716. SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[3,1][0m 0.91ms]
  1717.  
  1718.           1         Unit: 0 Slot: 0 Port: 1 Gigabit - Level 0x8010001                                   SQL[[1;33mSELECT * FROM `ports_vlans` WHERE device_id = ? AND port_id = ? AND `vlan` = ? [0;33m[3,44,1][0m 0.98ms]
  1719.  
  1720. SQL[[1;33mUPDATE `ports_vlans` set `baseport`=?,`priority`=?,`state`=?,`cost`=?,`untagged`=? WHERE `port_vlan_id` = ? [0;33m[1,0,"unknown",0,1,301][0m 0.39ms]
  1721.  
  1722. Updated
  1723. SQL[[1;33mDELETE FROM `ports_vlans` WHERE `device_id`=? AND `port_vlan_id` NOT IN (?) [0;33m[3,301][0m 0.55ms]
  1724.  
  1725. Deleted 0 vlan mappings  
  1726.  
  1727. >> Runtime for discovery module 'vlans': 0.1510 seconds with 52976 bytes
  1728. >> [0;36mSNMP[0m: [5/0.14s] [1;33mMySQL[0m: [6/0.04s] [0;32mRRD[0m: [0/0.00s]  
  1729. #### Unload disco module vlans ####
  1730.  
  1731. Modules status: Global-  
  1732. OS  
  1733. Device  
  1734. Module [ vmware-vminfo ] disabled globally.
  1735.  
  1736. Modules status: Global-  
  1737. OS  
  1738. Device  
  1739. Module [ libvirt-vminfo ] disabled globally.
  1740.  
  1741. Modules status: Global+  
  1742. OS  
  1743. Device-  
  1744. Module [ printer-supplies ] disabled on host.
  1745.  
  1746. Modules status: Global+  
  1747. OS  
  1748. Device-  
  1749. Module [ ucd-diskio ] disabled on host.
  1750.  
  1751. Modules status: Global+  
  1752. OS  
  1753. Device  
  1754.  
  1755. #### Load disco module applications ####
  1756.  
  1757. Applications: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'nsExtendStatus'[0m]
  1758. nsExtendStatus = No Such Object available on this agent at this OID  
  1759.  
  1760. Invalid snmp_walk() data = nsExtendStatus = No Such Object available on this agent at this OID  
  1761.  
  1762. Available:  
  1763. Checking for:  
  1764. SQL[[1;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`=? ORDER BY `app_type` [0;33m[3][0m 0.68ms]
  1765.  
  1766. SQL[[1;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL [0;33m[][0m 1.39ms]
  1767.  
  1768.  
  1769.  
  1770. >> Runtime for discovery module 'applications': 0.0270 seconds with 2496 bytes
  1771. >> [0;36mSNMP[0m: [1/0.02s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.00s]  
  1772. #### Unload disco module applications ####
  1773.  
  1774. Modules status: Global+  
  1775. OS  
  1776. Device  
  1777.  
  1778. #### Load disco module services ####
  1779.  
  1780. >> Runtime for discovery module 'services': 0.0000 seconds with 768 bytes
  1781. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]  
  1782. #### Unload disco module services ####
  1783.  
  1784. Modules status: Global+  
  1785. OS  
  1786. Device  
  1787.  
  1788. #### Load disco module stp ####
  1789. Instances: SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0'[0m]  
  1790. BRIDGE-MIB::dot1dStpProtocolSpecification.0 = 3
  1791.  
  1792.  
  1793. SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUt' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dBaseBridgeAddress.0' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0' 'BRIDGE-MIB::dot1dStpPriority.0' 'BRIDGE-MIB::dot1dStpTimeSinceTopologyChange.0' 'BRIDGE-MIB::dot1dStpTopChanges.0' 'BRIDGE-MIB::dot1dStpDesignatedRoot.0' 'BRIDGE-MIB::dot1dStpRootCost.0' 'BRIDGE-MIB::dot1dStpRootPort.0' 'BRIDGE-MIB::dot1dStpMaxAge.0' 'BRIDGE-MIB::dot1dStpHelloTime.0' 'BRIDGE-MIB::dot1dStpHoldTime.0' 'BRIDGE-MIB::dot1dStpForwardDelay.0' 'BRIDGE-MIB::dot1dStpBridgeMaxAge.0' 'BRIDGE-MIB::dot1dStpBridgeHelloTime.0' 'BRIDGE-MIB::dot1dStpBridgeForwardDelay.0'[0m]  
  1794. BRIDGE-MIB::dot1dBaseBridgeAddress.0 = a0:b4:39:3f:84:80
  1795. BRIDGE-MIB::dot1dStpProtocolSpecification.0 = ieee8021d
  1796. BRIDGE-MIB::dot1dStpPriority.0 = 32768
  1797. BRIDGE-MIB::dot1dStpTimeSinceTopologyChange.0 = 0
  1798. BRIDGE-MIB::dot1dStpTopChanges.0 = 0
  1799. BRIDGE-MIB::dot1dStpDesignatedRoot.0 = "00 00 A0 B4 39 3F 84 80 "
  1800. BRIDGE-MIB::dot1dStpRootCost.0 = 0
  1801. BRIDGE-MIB::dot1dStpRootPort.0 = 0
  1802. BRIDGE-MIB::dot1dStpMaxAge.0 = 0
  1803. BRIDGE-MIB::dot1dStpHelloTime.0 = 0
  1804. BRIDGE-MIB::dot1dStpHoldTime.0 = 1
  1805. BRIDGE-MIB::dot1dStpForwardDelay.0 = 0
  1806. BRIDGE-MIB::dot1dStpBridgeMaxAge.0 = 2000
  1807. BRIDGE-MIB::dot1dStpBridgeHelloTime.0 = 200
  1808. BRIDGE-MIB::dot1dStpBridgeForwardDelay.0 = 1500
  1809.  
  1810.  
  1811. VLAN: 1 Bridge: a0:b4:39:3f:84:80 DR: 00 00 A0 B4 39 3F 84 80  
  1812. SQL[[1;33mselect * from `stp` where `stp`.`device_id` = ? and `stp`.`device_id` is not null [0;33m[3][0m 0.75ms]
  1813.  
  1814. SQL[[1;33mupdate `stp` set `holdTime` = ? where `stp_id` = ? [0;33m[0.01,2][0m 0.49ms]
  1815.  
  1816. Updated data:  
  1817. array (
  1818.   'holdTime' => 0.01,
  1819. )  
  1820.  
  1821. Ports: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' '-v2c' '-c' 'COMMUNITY' '-OQXUt' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpPortTable'[0m]  
  1822. BRIDGE-MIB::dot1dStpPort[1] = 1
  1823. BRIDGE-MIB::dot1dStpPortPriority[1] = 128
  1824. BRIDGE-MIB::dot1dStpPortState[1] = forwarding
  1825. BRIDGE-MIB::dot1dStpPortEnable[1] = enabled
  1826. BRIDGE-MIB::dot1dStpPortPathCost[1] = 4
  1827. BRIDGE-MIB::dot1dStpPortDesignatedRoot[1] = "00 00 00 00 00 00 00 00 "
  1828. BRIDGE-MIB::dot1dStpPortDesignatedCost[1] = 0
  1829. BRIDGE-MIB::dot1dStpPortDesignatedBridge[1] = "00 00 00 00 00 00 00 00 "
  1830. BRIDGE-MIB::dot1dStpPortDesignatedPort[1] = "00 00 "
  1831. BRIDGE-MIB::dot1dStpPortForwardTransitions[1] = 0
  1832.  
  1833.  
  1834. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dBasePortIfIndex'[0m]
  1835. dot1dBasePortIfIndex.1 = 1  
  1836.  
  1837. SQL[[1;33mselect `port_id`, `ifIndex` from `ports` where `ports`.`device_id` = ? and `ports`.`device_id` is not null [0;33m[3][0m 0.82ms]
  1838.  
  1839. Discovered STP port 1 (): 44  
  1840. SQL[[1;33mselect * from `ports_stp` where `ports_stp`.`device_id` = ? and `ports_stp`.`device_id` is not null [0;33m[3][0m 0.81ms]
  1841.  
  1842. .
  1843.  
  1844. >> Runtime for discovery module 'stp': 0.0960 seconds with 79904 bytes
  1845. >> [0;36mSNMP[0m: [4/0.09s] [1;33mMySQL[0m: [4/0.03s] [0;32mRRD[0m: [0/0.00s]  
  1846. #### Unload disco module stp ####
  1847.  
  1848. Modules status: Global+  
  1849. OS  
  1850. Device-  
  1851. Module [ ntp ] disabled on host.
  1852.  
  1853. Modules status: Global-  
  1854. OS  
  1855. Device  
  1856. Module [ loadbalancers ] disabled globally.
  1857.  
  1858. Modules status: Global+  
  1859. OS  
  1860. Device  
  1861.  
  1862. #### Load disco module mef ####
  1863. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'MEF-UNI-EVC-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'MefServiceEvcCfgEntry'[0m]
  1864. mefServiceEvcCfgEntry = No more variables left in this MIB View (It is past the end of the MIB tree)  
  1865.  
  1866. MEF :
  1867. Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/mef.inc.php on line 20
  1868. SQL[[1;33mSELECT id, mefID, mefIdent FROM mefinfo WHERE device_id = '3' [0;33m[][0m 0.83ms]
  1869.  
  1870.  
  1871.  
  1872. >> Runtime for discovery module 'mef': 0.0330 seconds with 1312 bytes
  1873. >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]  
  1874. #### Unload disco module mef ####
  1875.  
  1876. Modules status: Global+  
  1877. OS  
  1878. Device  
  1879.  
  1880. #### Load disco module wireless ####
  1881. ap-count: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'CISCO-LWAPP-SYS-MIB::clsSysApConnectCount.0' 'AIRESPACE-SWITCHING-MIB::agentInventoryMaxNumberOfAPsSupported.0'[0m]
  1882. clsSysApConnectCount.0 = 35
  1883. agentInventoryMaxNumberOfAPsSupported.0 = 100  
  1884.  
  1885. Discovered LibreNMS\Device\WirelessSensor Array
  1886. (
  1887.     [sensor_class] => ap-count
  1888.     [device_id] => 3
  1889.     [sensor_oids] => [".1.3.6.1.4.1.9.9.618.1.8.4.0"]
  1890.     [sensor_index] => 0
  1891.     [sensor_type] => ciscowlc
  1892.     [sensor_descr] => Connected APs
  1893.     [sensor_divisor] => 1
  1894.     [sensor_multiplier] => 1
  1895.     [sensor_aggregator] => sum
  1896.     [sensor_limit] => 100
  1897.     [sensor_limit_warn] =>
  1898.     [sensor_limit_low] => 0
  1899.     [sensor_limit_low_warn] =>
  1900.     [sensor_current] => 35
  1901.     [entPhysicalIndex] =>
  1902.     [entPhysicalIndex_measured] =>
  1903.     [access_point_id] =>
  1904. )  
  1905. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"ap-count","ciscowlc",0][0m 0.87ms]
  1906.  
  1907. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_id` NOT IN (?) [0;33m[3,"ap-count",1][0m 0.5ms]
  1908.  
  1909.  
  1910. clients: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'AIRESPACE-WIRELESS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bsnDot11EssSsid'[0m]
  1911. bsnDot11EssSsid.1 = SRAEY001-Akis
  1912. bsnDot11EssSsid.2 = AKISHANDHELD
  1913. bsnDot11EssSsid.3 = Guest@Sika
  1914. bsnDot11EssSsid.4 = MOBILE@SIKA  
  1915.  
  1916. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUs' '-m' 'AIRESPACE-WIRELESS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'bsnDot11EssNumberOfMobileStations'[0m]
  1917. bsnDot11EssNumberOfMobileStations.1 = 40
  1918. bsnDot11EssNumberOfMobileStations.2 = 8
  1919. bsnDot11EssNumberOfMobileStations.3 = 97
  1920. bsnDot11EssNumberOfMobileStations.4 = 27  
  1921.  
  1922. Discovered LibreNMS\Device\WirelessSensor Array
  1923. (
  1924.     [sensor_class] => clients
  1925.     [device_id] => 3
  1926.     [sensor_oids] => [".1.3.6.1.4.1.14179.2.1.1.1.38.1"]
  1927.     [sensor_index] => 1
  1928.     [sensor_type] => ciscowlc-ssid
  1929.     [sensor_descr] => SSID: SRAEY001-Akis
  1930.     [sensor_divisor] => 1
  1931.     [sensor_multiplier] => 1
  1932.     [sensor_aggregator] => sum
  1933.     [sensor_limit] =>
  1934.     [sensor_limit_warn] =>
  1935.     [sensor_limit_low] =>
  1936.     [sensor_limit_low_warn] =>
  1937.     [sensor_current] => 40
  1938.     [entPhysicalIndex] =>
  1939.     [entPhysicalIndex_measured] =>
  1940.     [access_point_id] =>
  1941. )  
  1942. Discovered LibreNMS\Device\WirelessSensor Array
  1943. (
  1944.     [sensor_class] => clients
  1945.     [device_id] => 3
  1946.     [sensor_oids] => [".1.3.6.1.4.1.14179.2.1.1.1.38.2"]
  1947.     [sensor_index] => 2
  1948.     [sensor_type] => ciscowlc-ssid
  1949.     [sensor_descr] => SSID: AKISHANDHELD
  1950.     [sensor_divisor] => 1
  1951.     [sensor_multiplier] => 1
  1952.     [sensor_aggregator] => sum
  1953.     [sensor_limit] =>
  1954.     [sensor_limit_warn] =>
  1955.     [sensor_limit_low] =>
  1956.     [sensor_limit_low_warn] =>
  1957.     [sensor_current] => 8
  1958.     [entPhysicalIndex] =>
  1959.     [entPhysicalIndex_measured] =>
  1960.     [access_point_id] =>
  1961. )  
  1962. Discovered LibreNMS\Device\WirelessSensor Array
  1963. (
  1964.     [sensor_class] => clients
  1965.     [device_id] => 3
  1966.     [sensor_oids] => [".1.3.6.1.4.1.14179.2.1.1.1.38.3"]
  1967.     [sensor_index] => 3
  1968.     [sensor_type] => ciscowlc-ssid
  1969.     [sensor_descr] => SSID: Guest@Sika
  1970.     [sensor_divisor] => 1
  1971.     [sensor_multiplier] => 1
  1972.     [sensor_aggregator] => sum
  1973.     [sensor_limit] =>
  1974.     [sensor_limit_warn] =>
  1975.     [sensor_limit_low] =>
  1976.     [sensor_limit_low_warn] =>
  1977.     [sensor_current] => 97
  1978.     [entPhysicalIndex] =>
  1979.     [entPhysicalIndex_measured] =>
  1980.     [access_point_id] =>
  1981. )  
  1982. Discovered LibreNMS\Device\WirelessSensor Array
  1983. (
  1984.     [sensor_class] => clients
  1985.     [device_id] => 3
  1986.     [sensor_oids] => [".1.3.6.1.4.1.14179.2.1.1.1.38.4"]
  1987.     [sensor_index] => 4
  1988.     [sensor_type] => ciscowlc-ssid
  1989.     [sensor_descr] => SSID: MOBILE@SIKA
  1990.     [sensor_divisor] => 1
  1991.     [sensor_multiplier] => 1
  1992.     [sensor_aggregator] => sum
  1993.     [sensor_limit] =>
  1994.     [sensor_limit_warn] =>
  1995.     [sensor_limit_low] =>
  1996.     [sensor_limit_low_warn] =>
  1997.     [sensor_current] => 27
  1998.     [entPhysicalIndex] =>
  1999.     [entPhysicalIndex_measured] =>
  2000.     [access_point_id] =>
  2001. )  
  2002. Discovered LibreNMS\Device\WirelessSensor Array
  2003. (
  2004.     [sensor_class] => clients
  2005.     [device_id] => 3
  2006.     [sensor_oids] => [".1.3.6.1.4.1.14179.2.1.1.1.38.1",".1.3.6.1.4.1.14179.2.1.1.1.38.2",".1.3.6.1.4.1.14179.2.1.1.1.38.3",".1.3.6.1.4.1.14179.2.1.1.1.38.4"]
  2007.     [sensor_index] => 0
  2008.     [sensor_type] => ciscowlc
  2009.     [sensor_descr] => Clients: Total
  2010.     [sensor_divisor] => 1
  2011.     [sensor_multiplier] => 1
  2012.     [sensor_aggregator] => sum
  2013.     [sensor_limit] =>
  2014.     [sensor_limit_warn] =>
  2015.     [sensor_limit_low] =>
  2016.     [sensor_limit_low_warn] =>
  2017.     [sensor_current] => 172
  2018.     [entPhysicalIndex] =>
  2019.     [entPhysicalIndex_measured] =>
  2020.     [access_point_id] =>
  2021. )  
  2022. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"clients","ciscowlc-ssid",1][0m 1.39ms]
  2023.  
  2024. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"clients","ciscowlc-ssid",2][0m 0.42ms]
  2025.  
  2026. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"clients","ciscowlc-ssid",3][0m 0.43ms]
  2027.  
  2028. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"clients","ciscowlc-ssid",4][0m 0.48ms]
  2029.  
  2030. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_type`=? AND `sensor_index`=? [0;33m[3,"clients","ciscowlc",0][0m 0.63ms]
  2031.  
  2032. .SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? AND `sensor_id` NOT IN (?,?,?,?,?) [0;33m[3,"clients",7,8,9,10,11][0m 0.52ms]
  2033.  
  2034.  
  2035. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"quality"][0m 1.08ms]
  2036.  
  2037. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"capacity"][0m 0.44ms]
  2038.  
  2039. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"utilization"][0m 0.53ms]
  2040.  
  2041. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"rate"][0m 0.5ms]
  2042.  
  2043. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"ccq"][0m 0.45ms]
  2044.  
  2045. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"snr"][0m 0.48ms]
  2046.  
  2047. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"sinr"][0m 0.45ms]
  2048.  
  2049. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"rsrp"][0m 0.73ms]
  2050.  
  2051. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"rsrq"][0m 0.43ms]
  2052.  
  2053. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"ssr"][0m 0.38ms]
  2054.  
  2055. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"mse"][0m 0.52ms]
  2056.  
  2057. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"xpi"][0m 0.44ms]
  2058.  
  2059. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"rssi"][0m 0.44ms]
  2060.  
  2061. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"power"][0m 0.36ms]
  2062.  
  2063. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"noise-floor"][0m 0.29ms]
  2064.  
  2065. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"errors"][0m 0.26ms]
  2066.  
  2067. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"error-ratio"][0m 0.27ms]
  2068.  
  2069. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"error-rate"][0m 0.37ms]
  2070.  
  2071. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"frequency"][0m 0.3ms]
  2072.  
  2073. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"distance"][0m 0.28ms]
  2074.  
  2075. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"cell"][0m 0.25ms]
  2076.  
  2077. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[3,"channel"][0m 0.23ms]
  2078.  
  2079.  
  2080. >> Runtime for discovery module 'wireless': 0.1400 seconds with 194856 bytes
  2081. >> [0;36mSNMP[0m: [3/0.12s] [1;33mMySQL[0m: [30/0.15s] [0;32mRRD[0m: [0/0.00s]  
  2082. #### Unload disco module wireless ####
  2083.  
  2084. Modules status: Global+  
  2085. OS  
  2086. Device  
  2087.  
  2088. #### Load disco module fdb-table ####
  2089. SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[3][0m 0.27ms]
  2090.  
  2091. SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[3][0m 0.23ms]
  2092.  
  2093. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m]
  2094. dot1qTpFdbPort = No Such Instance currently exists at this OID  
  2095.  
  2096. SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Cc' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cisco' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m]
  2097. dot1dTpFdbPort = No Such Instance currently exists at this OID  
  2098.  
  2099.  
  2100.  
  2101. >> Runtime for discovery module 'fdb-table': 0.0530 seconds with 1544 bytes
  2102. >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [2/0.01s] [0;32mRRD[0m: [0/0.00s]  
  2103. #### Unload disco module fdb-table ####
  2104.  
  2105. Modules status: Global+  
  2106. OS  
  2107. Device-  
  2108. Module [ mpls ] disabled on host.
  2109.  
  2110. SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[3.047,3][0m 0.57ms]
  2111.  
  2112. Discovered in 3.047 seconds
  2113.  
  2114. ./discovery.php brapciscoosa000.br.sika.com 2022-02-07 12:20:27 - 1 devices discovered in 3.314 secs  
  2115.  
  2116. [0;36mSNMP[0m [59/1.46s]: Snmpget[15/0.32s] Snmptranslate[1/0.04s] Snmpwalk[42/1.08s] Snmpgetnext[1/0.02s]  
  2117. [1;33mSQL[0m [228/1.29s]: Select[169/0.97s] Update[45/0.21s] Delete[10/0.08s] Insert[3/0.01s]
  2118. [1/0.02s]  
  2119. [0;32mRRD[0m [0/0.00s]:  
  2120.  

Replies to Untitled rss

Title Name Language When
SNMP - CiscoWLC Ygor Almeida text 2 Years ago.
captcha