  2. VERTIV-V5-MIB DEFINITIONS ::= BEGIN
  3.  
  4. IMPORTS
  5.  
  6. DisplayString, TruthValue, MacAddress FROM SNMPv2-TC
  7. SnmpAdminString FROM SNMP-FRAMEWORK-MIB
  8. MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32,
  9. Gauge32, NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
  10. sysName FROM SNMPv2-MIB;
  11.  
  12. vertiv MODULE-IDENTITY
  13.  LAST-UPDATED "202001070000Z"
  14.  ORGANIZATION "Vertiv"
  15.  CONTACT-INFO "support@geistglobal.com"
  16.  DESCRIPTION
  17.   "The MIB for Vertiv products"
  18.  
  19.  REVISION "202001070000Z"
  20.  DESCRIPTION
  21.   "Updates for VRC spec change"
  22.  
  23.  REVISION "201909300000Z"
  24.  DESCRIPTION
  25.   "Added hostname, alarm/warning count, and manufacturer to deviceInfo"
  26.  
  27.  REVISION "201909120000Z"
  28.  DESCRIPTION
  29.   "Added SN-2D door switch sensor"
  30.  
  31.  REVISION "201908300000Z"
  32.  DESCRIPTION
  33.   "Removed current min, max, and peak fields from pdu phase, line,
  34.   breaker, and outlet tables
  35.   Removed voltage min, max, and peak fields from pdu phase, line,
  36.   breaker, and outlet tables
  37.   Removed minmax reset value from pduOutletMeterReset
  38.   Added balance field to pdu phase table"
  39.  
  40.  REVISION "201906060000Z"
  41.  DESCRIPTION
  42.   "Updated pduOutletSwitchControl description"
  43.  
  44.  REVISION "201905070000Z"
  45.  DESCRIPTION
  46.   "Changed productMacAddress type to MacAddress"
  47.  
  48.  REVISION "201904300000Z"
  49.  DESCRIPTION
  50.   "Added remote humidity-only sensor"
  51.  
  52.  REVISION "201903070000Z"
  53.  DESCRIPTION
  54.   "Added VRC support"
  55.  
  56.  REVISION "201801190000Z"
  57.  DESCRIPTION
  58.   "Modified pduOutletSwitchTable to support outlet actions with delays"
  59.  
  60.  REVISION "201709190000Z"
  61.  DESCRIPTION
  62.   "Changed SYNTAX of objects, with a UTF-8 encoded string value, to
  63.   SnmpAdminString"
  64.  
  65.  REVISION "201708100000Z"
  66.  DESCRIPTION
  67.   "Added pduBreakerCurrentPeak, pduLineCurrentPeak,
  68.   pduOutletMeterCurrentPeak, pduPhaseVoltagePeak, and
  69.   pduPhaseCurrentPeak
  70.   Updated object descriptions, indicating which fields are not supported
  71.   on all platforms"
  72.  
  73.  REVISION "201705100000Z"
  74.  DESCRIPTION
  75.   "Added trapObj group with trap payload objects
  76.   Added additional payload objects to trap definitions"
  77.  
  78.  REVISION "201704050000Z"
  79.  DESCRIPTION
  80.   "Added productPlatform to deviceInfo group
  81.   Added product identity entries"
  82.  
  83.  REVISION "201606300000Z"
  84.  DESCRIPTION
  85.   "Raven version"
  86.  
  87.  REVISION "201209110000Z"
  88.  DESCRIPTION
  89.   "Original version"
  90.  ::= { enterprises 21239 }
  91.  
  92. v5 OBJECT IDENTIFIER ::= { vertiv 5 }
  93.  
  94. imd OBJECT IDENTIFIER ::= { v5 2 }
  95.  
  96. --###########################################################################################--
  97. --deviceInfo--
  98. --###########################################################################################--
  99.  
  100. deviceInfo OBJECT IDENTIFIER ::= { imd 1 }
  101.  
  102. productTitle OBJECT-TYPE
  103.  SYNTAX SnmpAdminString
  104.  MAX-ACCESS read-only
  105.  STATUS current
  106.  DESCRIPTION
  107.   "Product name"
  108.  ::= { deviceInfo 1 }
  109.  
  110. productVersion OBJECT-TYPE
  111.  SYNTAX SnmpAdminString
  112.  MAX-ACCESS read-only
  113.  STATUS current
  114.  DESCRIPTION
  115.   "Product version"
  116.  ::= { deviceInfo 2 }
  117.  
  118. productFriendlyName OBJECT-TYPE
  119.  SYNTAX SnmpAdminString
  120.  MAX-ACCESS read-only
  121.  STATUS current
  122.  DESCRIPTION
  123.   "User-assigned name"
  124.  ::= { deviceInfo 3 }
  125.  
  126. productMacAddress OBJECT-TYPE
  127.  SYNTAX MacAddress
  128.  MAX-ACCESS read-only
  129.  STATUS current
  130.  DESCRIPTION
  131.   "Product's unique MAC address"
  132.  ::= { deviceInfo 4 }
  133.  
  134. deviceCount OBJECT-TYPE
  135.  SYNTAX Integer32(0..16)
  136.  MAX-ACCESS read-only
  137.  STATUS current
  138.  DESCRIPTION
  139.   "Total number of devices on unit"
  140.  ::= { deviceInfo 6 }
  141.  
  142. temperatureUnits OBJECT-TYPE
  143.  SYNTAX INTEGER {
  144.    fahrenheit(0),
  145.    celsius(1)
  146.    }
  147.  MAX-ACCESS read-write
  148.  STATUS current
  149.  DESCRIPTION
  150.   "Current units for temperature/dewpoint values:
  151.   0 = Degrees Fahrenheit
  152.   1 = Degrees Celsius"
  153.  ::= { deviceInfo 7 }
  154.  
  155. productModelNumber OBJECT-TYPE
  156.  SYNTAX SnmpAdminString
  157.  MAX-ACCESS read-only
  158.  STATUS current
  159.  DESCRIPTION
  160.   "Product model number (factory-assigned)"
  161.  ::= { deviceInfo 8 }
  162.  
  163. productPartNumber OBJECT-TYPE
  164.  SYNTAX SnmpAdminString
  165.  MAX-ACCESS read-only
  166.  STATUS current
  167.  DESCRIPTION
  168.   "Product part number (factory-assigned)"
  169.  ::= { deviceInfo 9 }
  170.  
  171. productSerialNumber OBJECT-TYPE
  172.  SYNTAX SnmpAdminString
  173.  MAX-ACCESS read-only
  174.  STATUS current
  175.  DESCRIPTION
  176.   "Product serial number (factory-assigned)"
  177.  ::= { deviceInfo 10 }
  178.  
  179. productPlatform OBJECT-TYPE
  180.  SYNTAX SnmpAdminString
  181.  MAX-ACCESS read-only
  182.  STATUS current
  183.  DESCRIPTION
  184.   "Product platform"
  185.  ::= { deviceInfo 11 }
  186.  
  187. productHostname OBJECT-TYPE
  188.  SYNTAX SnmpAdminString
  189.  MAX-ACCESS read-only
  190.  STATUS current
  191.  DESCRIPTION
  192.   "Product hostname"
  193.  ::= { deviceInfo 12 }
  194.  
  195. productAlarmCount OBJECT-TYPE
  196.  SYNTAX Integer32
  197.  MAX-ACCESS read-only
  198.  STATUS current
  199.  DESCRIPTION
  200.   "Number of alarms currently tripped"
  201.  ::= { deviceInfo 13 }
  202.  
  203. productWarnCount OBJECT-TYPE
  204.  SYNTAX Integer32
  205.  MAX-ACCESS read-only
  206.  STATUS current
  207.  DESCRIPTION
  208.   "Number of warnings currently tripped"
  209.  ::= { deviceInfo 14 }
  210.  
  211. productManufacturer OBJECT-TYPE
  212.  SYNTAX SnmpAdminString
  213.  MAX-ACCESS read-only
  214.  STATUS current
  215.  DESCRIPTION
  216.   "Product manufacturer"
  217.  ::= { deviceInfo 15 }
  218.  
  219. --###########################################################################################--
  220. --pdu--
  221. --###########################################################################################--
  222.  
  223. pdu OBJECT IDENTIFIER ::= { imd 3 }
  224.  
  225. --###########################################################################################--
  226. --pduMainTable--
  227. --###########################################################################################--
  228.  
  229. pduMainTable OBJECT-TYPE
  230.  SYNTAX SEQUENCE OF PduMainEntry
  231.  MAX-ACCESS  not-accessible
  232.  STATUS current
  233.  DESCRIPTION
  234.   "PDU general information"
  235.  ::= { pdu 1 }
  236.  
  237. pduMainEntry OBJECT-TYPE
  238.  SYNTAX PduMainEntry
  239.  MAX-ACCESS  not-accessible
  240.  STATUS current
  241.  DESCRIPTION
  242.   "Entry in the pduMainTable table: each entry contains an index
  243.   and other sensor details"
  244.  INDEX { pduMainIndex }
  245.  ::= { pduMainTable 1 }
  246.  
  247. PduMainEntry ::= SEQUENCE {
  248.  pduMainIndex    Integer32,
  249.  pduMainSerial    DisplayString,
  250.  pduMainName    SnmpAdminString,
  251.  pduMainLabel    SnmpAdminString,
  252.  pduMainAvail    Gauge32,
  253.  pduMeterType    INTEGER,
  254.  pduTotalName    SnmpAdminString,
  255.  pduTotalLabel    SnmpAdminString,
  256.  pduTotalRealPower    Gauge32,
  257.  pduTotalApparentPower    Gauge32,
  258.  pduTotalPowerFactor    Gauge32,
  259.  pduTotalEnergy    Gauge32
  260. }
  261.  
  262. pduMainIndex OBJECT-TYPE
  263.  SYNTAX Integer32(1..100)
  264.  MAX-ACCESS not-accessible
  265.  STATUS current
  266.  DESCRIPTION
  267.   "Table entry index value"
  268.  ::= { pduMainEntry 1 }
  269.  
  270. pduMainSerial OBJECT-TYPE
  271.  SYNTAX DisplayString
  272.  MAX-ACCESS read-only
  273.  STATUS current
  274.  DESCRIPTION
  275.   "Serial number"
  276.  ::= { pduMainEntry 2 }
  277.  
  278. pduMainName OBJECT-TYPE
  279.  SYNTAX SnmpAdminString(SIZE (1..25))
  280.  MAX-ACCESS read-only
  281.  STATUS current
  282.  DESCRIPTION
  283.   "PDU name (factory-assigned)"
  284.  ::= { pduMainEntry 3 }
  285.  
  286. pduMainLabel OBJECT-TYPE
  287.  SYNTAX SnmpAdminString(SIZE (0..25))
  288.  MAX-ACCESS read-write
  289.  STATUS current
  290.  DESCRIPTION
  291.   "PDU label (user-defined)"
  292.  ::= { pduMainEntry 4 }
  293.  
  294. pduMainAvail OBJECT-TYPE
  295.  SYNTAX Gauge32
  296.  MAX-ACCESS read-only
  297.  STATUS current
  298.  DESCRIPTION
  299.   "Device availability:
  300.   0 = Unavailable
  301.   1 = Available
  302.   2 = Partially Unavailable"
  303.  ::= { pduMainEntry 5 }
  304.  
  305. pduMeterType OBJECT-TYPE
  306.  SYNTAX INTEGER {
  307.    wye(0),
  308.    delta(1)
  309.    }
  310.  MAX-ACCESS read-only
  311.  STATUS current
  312.  DESCRIPTION
  313.   "Current meter type:
  314.   0 = Wye
  315.   1 = Delta"
  316.  ::= { pduMainEntry 6 }
  317.  
  318. pduTotalName OBJECT-TYPE
  319.  SYNTAX SnmpAdminString(SIZE (1..25))
  320.  MAX-ACCESS read-only
  321.  STATUS current
  322.  DESCRIPTION
  323.   "Total name (factory-assigned)"
  324.  ::= { pduMainEntry 7 }
  325.  
  326. pduTotalLabel OBJECT-TYPE
  327.  SYNTAX SnmpAdminString(SIZE (0..25))
  328.  MAX-ACCESS read-write
  329.  STATUS current
  330.  DESCRIPTION
  331.   "Total label (user-defined)"
  332.  ::= { pduMainEntry 8 }
  333.  
  334. pduTotalRealPower OBJECT-TYPE
  335.  SYNTAX Gauge32(0..9999)
  336.  UNITS "watts"
  337.  MAX-ACCESS read-only
  338.  STATUS current
  339.  DESCRIPTION
  340.   "PDU total real power"
  341.  ::= { pduMainEntry 9 }
  342.  
  343. pduTotalApparentPower OBJECT-TYPE
  344.  SYNTAX Gauge32(0..9999)
  345.  UNITS "volt-amps"
  346.  MAX-ACCESS read-only
  347.  STATUS current
  348.  DESCRIPTION
  349.   "PDU total apparent power"
  350.  ::= { pduMainEntry 10 }
  351.  
  352. pduTotalPowerFactor OBJECT-TYPE
  353.  SYNTAX Gauge32(0..100)
  354.  UNITS "%"
  355.  MAX-ACCESS read-only
  356.  STATUS current
  357.  DESCRIPTION
  358.   "PDU total power factor"
  359.  ::= { pduMainEntry 11 }
  360.  
  361. pduTotalEnergy OBJECT-TYPE
  362.  SYNTAX Gauge32(0..9999000)
  363.  UNITS "watt-hours"
  364.  MAX-ACCESS read-only
  365.  STATUS current
  366.  DESCRIPTION
  367.   "PDU total accumulated energy in watt-hours"
  368.  ::= { pduMainEntry 12 }
  369.  
  370. --###########################################################################################--
  371. --pduPhaseTable--
  372. --###########################################################################################--
  373.  
  374. pduPhaseTable OBJECT-TYPE
  375.  SYNTAX SEQUENCE OF PduPhaseEntry
  376.  MAX-ACCESS  not-accessible
  377.  STATUS current
  378.  DESCRIPTION
  379.   "PDU phases information"
  380.  ::= { pdu 2 }
  381.  
  382. pduPhaseEntry OBJECT-TYPE
  383.  SYNTAX PduPhaseEntry
  384.  MAX-ACCESS  not-accessible
  385.  STATUS current
  386.  DESCRIPTION
  387.   "Entry in the pduPhaseTable table: each entry contains an index
  388.   and other sensor details"
  389.  INDEX { pduPhaseIndex }
  390.  ::= { pduPhaseTable 1 }
  391.  
  392. PduPhaseEntry ::= SEQUENCE {
  393.  pduPhaseIndex    Integer32,
  394.  pduPhaseName    SnmpAdminString,
  395.  pduPhaseLabel    SnmpAdminString,
  396.  pduPhaseVoltage    Gauge32,
  397.  pduPhaseCurrent    Gauge32,
  398.  pduPhaseRealPower    Gauge32,
  399.  pduPhaseApparentPower    Gauge32,
  400.  pduPhasePowerFactor    Gauge32,
  401.  pduPhaseEnergy    Gauge32,
  402.  pduPhaseBalance    Gauge32,
  403.  pduPhaseCurrentCrestFactor    Gauge32
  404. }
  405.  
  406. pduPhaseIndex OBJECT-TYPE
  407.  SYNTAX Integer32(1..100)
  408.  MAX-ACCESS not-accessible
  409.  STATUS current
  410.  DESCRIPTION
  411.   "Table entry index value"
  412.  ::= { pduPhaseEntry 1 }
  413.  
  414. pduPhaseName OBJECT-TYPE
  415.  SYNTAX SnmpAdminString(SIZE (0..25))
  416.  MAX-ACCESS read-only
  417.  STATUS current
  418.  DESCRIPTION
  419.   "PDU phase name (factory-assigned)"
  420.  ::= { pduPhaseEntry 2 }
  421.  
  422. pduPhaseLabel OBJECT-TYPE
  423.  SYNTAX SnmpAdminString(SIZE (1..25))
  424.  MAX-ACCESS read-write
  425.  STATUS current
  426.  DESCRIPTION
  427.   "PDU phase label (user-defined)"
  428.  ::= { pduPhaseEntry 3 }
  429.  
  430. pduPhaseVoltage OBJECT-TYPE
  431.  SYNTAX Gauge32(0..3100)
  432.  UNITS "decivolts (rms)"
  433.  MAX-ACCESS read-only
  434.  STATUS current
  435.  DESCRIPTION
  436.   "PDU phase voltage in tenths of a volt"
  437.  ::= { pduPhaseEntry 4 }
  438.  
  439. pduPhaseCurrent OBJECT-TYPE
  440.  SYNTAX Gauge32(0..9900)
  441.  UNITS "centiamps (rms)"
  442.  MAX-ACCESS read-only
  443.  STATUS current
  444.  DESCRIPTION
  445.   "PDU phase current reading in hundredths of an amp"
  446.  ::= { pduPhaseEntry 8 }
  447.  
  448. pduPhaseRealPower OBJECT-TYPE
  449.  SYNTAX Gauge32(0..9999)
  450.  UNITS "watts"
  451.  MAX-ACCESS read-only
  452.  STATUS current
  453.  DESCRIPTION
  454.   "Real power for phase in watts"
  455.  ::= { pduPhaseEntry 12 }
  456.  
  457. pduPhaseApparentPower OBJECT-TYPE
  458.  SYNTAX Gauge32(0..9999)
  459.  UNITS "volt-amps"
  460.  MAX-ACCESS read-only
  461.  STATUS current
  462.  DESCRIPTION
  463.   "Apparent power for phase in volt-amps"
  464.  ::= { pduPhaseEntry 13 }
  465.  
  466. pduPhasePowerFactor OBJECT-TYPE
  467.  SYNTAX Gauge32(0..100)
  468.  UNITS "%"
  469.  MAX-ACCESS read-only
  470.  STATUS current
  471.  DESCRIPTION
  472.   "Power factor for phase"
  473.  ::= { pduPhaseEntry 14 }
  474.  
  475. pduPhaseEnergy OBJECT-TYPE
  476.  SYNTAX Gauge32(0..9999000)
  477.  UNITS "watt-hours"
  478.  MAX-ACCESS read-only
  479.  STATUS current
  480.  DESCRIPTION
  481.   "Accumulated energy for phase in watt-hours"
  482.  ::= { pduPhaseEntry 15 }
  483.  
  484. pduPhaseBalance OBJECT-TYPE
  485.  SYNTAX Gauge32(0..100)
  486.  UNITS "%"
  487.  MAX-ACCESS read-only
  488.  STATUS current
  489.  DESCRIPTION
  490.   "Phase balance as percent"
  491.  ::= { pduPhaseEntry 17 }
  492.  
  493. pduPhaseCurrentCrestFactor OBJECT-TYPE
  494.  SYNTAX Gauge32(0..9999)
  495.  MAX-ACCESS read-only
  496.  STATUS current
  497.  DESCRIPTION
  498.   "Current crest factor for phase, in hundredths"
  499.  ::= { pduPhaseEntry 19 }
  500.  
  501. --###########################################################################################--
  502. --pduBreakerTable--
  503. --###########################################################################################--
  504.  
  505. pduBreakerTable OBJECT-TYPE
  506.  SYNTAX SEQUENCE OF PduBreakerEntry
  507.  MAX-ACCESS  not-accessible
  508.  STATUS current
  509.  DESCRIPTION
  510.   "PDU breaker information"
  511.  ::= { pdu 3 }
  512.  
  513. pduBreakerEntry OBJECT-TYPE
  514.  SYNTAX PduBreakerEntry
  515.  MAX-ACCESS  not-accessible
  516.  STATUS current
  517.  DESCRIPTION
  518.   "Entry in the pduBreakerTable table: each entry contains an index
  519.   and other sensor details"
  520.  INDEX { pduBreakerIndex }
  521.  ::= { pduBreakerTable 1 }
  522.  
  523. PduBreakerEntry ::= SEQUENCE {
  524.  pduBreakerIndex    Integer32,
  525.  pduBreakerName    SnmpAdminString,
  526.  pduBreakerLabel    SnmpAdminString,
  527.  pduBreakerCurrent    Gauge32,
  528.  pduBreakerVoltage    Gauge32,
  529.  pduBreakerRealPower    Gauge32,
  530.  pduBreakerApparentPower    Gauge32,
  531.  pduBreakerPowerFactor    Gauge32,
  532.  pduBreakerEnergy    Gauge32
  533. }
  534.  
  535. pduBreakerIndex OBJECT-TYPE
  536.  SYNTAX Integer32(1..100)
  537.  MAX-ACCESS not-accessible
  538.  STATUS current
  539.  DESCRIPTION
  540.   "Table entry index value"
  541.  ::= { pduBreakerEntry 1 }
  542.  
  543. pduBreakerName OBJECT-TYPE
  544.  SYNTAX SnmpAdminString(SIZE (1..25))
  545.  MAX-ACCESS read-only
  546.  STATUS current
  547.  DESCRIPTION
  548.   "PDU breaker name (factory-assigned)"
  549.  ::= { pduBreakerEntry 2 }
  550.  
  551. pduBreakerLabel OBJECT-TYPE
  552.  SYNTAX SnmpAdminString(SIZE (0..25))
  553.  MAX-ACCESS read-write
  554.  STATUS current
  555.  DESCRIPTION
  556.   "PDU breaker label (user-defined)"
  557.  ::= { pduBreakerEntry 3 }
  558.  
  559. pduBreakerCurrent OBJECT-TYPE
  560.  SYNTAX Gauge32(0..9900)
  561.  UNITS "centiamps (rms)"
  562.  MAX-ACCESS read-only
  563.  STATUS current
  564.  DESCRIPTION
  565.   "PDU breaker current reading in hundredths of an amp"
  566.  ::= { pduBreakerEntry 4 }
  567.  
  568. pduBreakerVoltage OBJECT-TYPE
  569.  SYNTAX Gauge32(0..3100)
  570.  UNITS "decivolts (rms)"
  571.  MAX-ACCESS read-only
  572.  STATUS current
  573.  DESCRIPTION
  574.   "PDU breaker voltage in tenths of a volt. This object may not exist on
  575.   all platforms, due to hardware differences."
  576.  ::= { pduBreakerEntry 8 }
  577.  
  578. pduBreakerRealPower OBJECT-TYPE
  579.  SYNTAX Gauge32(0..9999)
  580.  UNITS "watts"
  581.  MAX-ACCESS read-only
  582.  STATUS current
  583.  DESCRIPTION
  584.   "Real power for breaker in watts. This object may not exist on all
  585.   platforms, due to hardware differences."
  586.  ::= { pduBreakerEntry 12 }
  587.  
  588. pduBreakerApparentPower OBJECT-TYPE
  589.  SYNTAX Gauge32(0..9999)
  590.  UNITS "volt-amps"
  591.  MAX-ACCESS read-only
  592.  STATUS current
  593.  DESCRIPTION
  594.   "Apparent power for breaker in volt-amps. This object may not exist on
  595.   all platforms, due to hardware differences."
  596.  ::= { pduBreakerEntry 13 }
  597.  
  598. pduBreakerPowerFactor OBJECT-TYPE
  599.  SYNTAX Gauge32(0..100)
  600.  UNITS "%"
  601.  MAX-ACCESS read-only
  602.  STATUS current
  603.  DESCRIPTION
  604.   "Power factor for breaker. This object may not exist on all platforms,
  605.   due to hardware differences."
  606.  ::= { pduBreakerEntry 14 }
  607.  
  608. pduBreakerEnergy OBJECT-TYPE
  609.  SYNTAX Gauge32(0..9999000)
  610.  UNITS "watt-hours"
  611.  MAX-ACCESS read-only
  612.  STATUS current
  613.  DESCRIPTION
  614.   "Accumulated energy for breaker in watt-hours. This object may not
  615.   exist on all platforms, due to hardware differences."
  616.  ::= { pduBreakerEntry 15 }
  617.  
  618. --###########################################################################################--
  619. --pduLineTable--
  620. --###########################################################################################--
  621.  
  622. pduLineTable OBJECT-TYPE
  623.  SYNTAX SEQUENCE OF PduLineEntry
  624.  MAX-ACCESS  not-accessible
  625.  STATUS current
  626.  DESCRIPTION
  627.   "PDU line current information"
  628.  ::= { pdu 4 }
  629.  
  630. pduLineEntry OBJECT-TYPE
  631.  SYNTAX PduLineEntry
  632.  MAX-ACCESS  not-accessible
  633.  STATUS current
  634.  DESCRIPTION
  635.   "Entry in the pduLineTable table: each entry contains an index
  636.   and other sensor details"
  637.  INDEX { pduLineIndex }
  638.  ::= { pduLineTable 1 }
  639.  
  640. PduLineEntry ::= SEQUENCE {
  641.  pduLineIndex    Integer32,
  642.  pduLineName    SnmpAdminString,
  643.  pduLineLabel    SnmpAdminString,
  644.  pduLineCurrent    Gauge32
  645. }
  646.  
  647. pduLineIndex OBJECT-TYPE
  648.  SYNTAX Integer32(1..100)
  649.  MAX-ACCESS not-accessible
  650.  STATUS current
  651.  DESCRIPTION
  652.   "Table entry index value"
  653.  ::= { pduLineEntry 1 }
  654.  
  655. pduLineName OBJECT-TYPE
  656.  SYNTAX SnmpAdminString(SIZE (1..25))
  657.  MAX-ACCESS read-only
  658.  STATUS current
  659.  DESCRIPTION
  660.   "PDU line name (factory-assigned)"
  661.  ::= { pduLineEntry 2 }
  662.  
  663. pduLineLabel OBJECT-TYPE
  664.  SYNTAX SnmpAdminString(SIZE (0..25))
  665.  MAX-ACCESS read-write
  666.  STATUS current
  667.  DESCRIPTION
  668.   "PDU line label (user-defined)"
  669.  ::= { pduLineEntry 3 }
  670.  
  671. pduLineCurrent OBJECT-TYPE
  672.  SYNTAX Gauge32(0..9900)
  673.  UNITS "centiamps (rms)"
  674.  MAX-ACCESS read-only
  675.  STATUS current
  676.  DESCRIPTION
  677.   "PDU line current reading in hundredths of an amp"
  678.  ::= { pduLineEntry 4 }
  679.  
  680. --###########################################################################################--
  681. --pduOutletSwitchTable--
  682. --###########################################################################################--
  683.  
  684. pduOutletSwitchTable OBJECT-TYPE
  685.  SYNTAX SEQUENCE OF PduOutletSwitchEntry
  686.  MAX-ACCESS  not-accessible
  687.  STATUS current
  688.  DESCRIPTION
  689.   "Data, config and control for outlets with switching"
  690.  ::= { pdu 5 }
  691.  
  692. pduOutletSwitchEntry OBJECT-TYPE
  693.  SYNTAX PduOutletSwitchEntry
  694.  MAX-ACCESS  not-accessible
  695.  STATUS current
  696.  DESCRIPTION
  697.   "Entry in the pduOutletSwitchTable table: each entry contains an index
  698.   and other sensor details"
  699.  INDEX { pduOutletSwitchIndex }
  700.  ::= { pduOutletSwitchTable 1 }
  701.  
  702. PduOutletSwitchEntry ::= SEQUENCE {
  703.  pduOutletSwitchIndex    Integer32,
  704.  pduOutletSwitchName    SnmpAdminString,
  705.  pduOutletSwitchLabel    SnmpAdminString,
  706.  pduOutletSwitchState    INTEGER,
  707.  pduOutletSwitchRelayFailure    TruthValue,
  708.  pduOutletSwitchControl    INTEGER,
  709.  pduOutletSwitchTimeToAction    Integer32,
  710.  pduOutletSwitchOnDelay    Integer32,
  711.  pduOutletSwitchOffDelay    Integer32,
  712.  pduOutletSwitchRebootDelay    Integer32,
  713.  pduOutletSwitchRebootHoldDelay    Integer32,
  714.  pduOutletSwitchPoaAction    INTEGER,
  715.  pduOutletSwitchPoaDelay    Integer32
  716. }
  717.  
  718. pduOutletSwitchIndex OBJECT-TYPE
  719.  SYNTAX Integer32(1..100)
  720.  MAX-ACCESS not-accessible
  721.  STATUS current
  722.  DESCRIPTION
  723.   "Table entry index value"
  724.  ::= { pduOutletSwitchEntry 1 }
  725.  
  726. pduOutletSwitchName OBJECT-TYPE
  727.  SYNTAX SnmpAdminString(SIZE (1..25))
  728.  MAX-ACCESS read-only
  729.  STATUS current
  730.  DESCRIPTION
  731.   "PDU outlet name (factory-assigned)"
  732.  ::= { pduOutletSwitchEntry 2 }
  733.  
  734. pduOutletSwitchLabel OBJECT-TYPE
  735.  SYNTAX SnmpAdminString(SIZE (0..25))
  736.  MAX-ACCESS read-write
  737.  STATUS current
  738.  DESCRIPTION
  739.   "PDU outlet label (user-defined)"
  740.  ::= { pduOutletSwitchEntry 3 }
  741.  
  742. pduOutletSwitchState OBJECT-TYPE
  743.  SYNTAX INTEGER {
  744.    on(1),
  745.    off(2),
  746.    on2off(3),
  747.    off2on(4),
  748.    rebootOn(5),
  749.    rebootOff(6),
  750.    unavailable(7)
  751.    }
  752.  MAX-ACCESS read-only
  753.  STATUS current
  754.  DESCRIPTION
  755.   "Switch state of the outlet:
  756.   1 = Outlet is on
  757.   2 = Outlet is off
  758.   3 = Outlet is on, but will turn off after a delay
  759.   4 = Outlet is off, but will turn on after a delay
  760.   5 = Starting reboot cycle, outlet is on, but will go to the
  761.   rebootOff(6) state after a delay
  762.   6 = Rebooting, outlet is off, but it will turn on after a delay
  763.   7 = Cannot get outlet state"
  764.  ::= { pduOutletSwitchEntry 4 }
  765.  
  766. pduOutletSwitchRelayFailure OBJECT-TYPE
  767.  SYNTAX TruthValue
  768.  MAX-ACCESS read-only
  769.  STATUS current
  770.  DESCRIPTION
  771.   "Tells if the outlet relay has failed. In normal operation, the value
  772.   will be false(2)."
  773.  ::= { pduOutletSwitchEntry 5 }
  774.  
  775. pduOutletSwitchControl OBJECT-TYPE
  776.  SYNTAX INTEGER {
  777.    cancel(1),
  778.    on(2),
  779.    onAfterDelay(3),
  780.    off(4),
  781.    offAfterDelay(5),
  782.    reboot(6),
  783.    rebootAfterDelay(7),
  784.    none(8)
  785.    }
  786.  MAX-ACCESS read-write
  787.  STATUS current
  788.  DESCRIPTION
  789.   "Used for manual control of the outlet. If the outlet is in manual
  790.   mode, this field can be set to one of the following values:
  791.   1 = Cancel pending operation
  792.   2 = Turn outlet on
  793.   3 = After delay (pduOutletSwitchOnDelay), turn outlet on
  794.   4 = Turn outlet off
  795.   5 = After delay (pduOutletSwitchOffDelay), turn outlet off
  796.   6 = Reboot: turn off, delay (pduOutletSwitchRebootHoldDelay), turn
  797.   outlet back on
  798.   7 = After delay (pduOutletSwitchRebootDelay), reboot outlet
  799.   When not in manual mode, setting this field will give an
  800.   inconsistentValue error. Returns none(8) for all get requests."
  801.  ::= { pduOutletSwitchEntry 6 }
  802.  
  803. pduOutletSwitchTimeToAction OBJECT-TYPE
  804.  SYNTAX Integer32(0..600)
  805.  MAX-ACCESS read-only
  806.  STATUS current
  807.  DESCRIPTION
  808.   "Seconds until an outlet state change. The value of
  809.   pduOutletSwitchState tells what state the outlet will be set, after
  810.   the delay."
  811.  ::= { pduOutletSwitchEntry 7 }
  812.  
  813. pduOutletSwitchOnDelay OBJECT-TYPE
  814.  SYNTAX Integer32(0..600)
  815.  MAX-ACCESS read-write
  816.  STATUS current
  817.  DESCRIPTION
  818.   "Seconds to wait before powering on the outlet, during onAfterDelay(3)
  819.   operation. Changing this value has no effect on pending actions."
  820.  ::= { pduOutletSwitchEntry 8 }
  821.  
  822. pduOutletSwitchOffDelay OBJECT-TYPE
  823.  SYNTAX Integer32(0..600)
  824.  MAX-ACCESS read-write
  825.  STATUS current
  826.  DESCRIPTION
  827.   "Seconds to wait before powering off the outlet, during
  828.   offAfterDelay(5) operation. Changing this value has no effect on
  829.   pending actions."
  830.  ::= { pduOutletSwitchEntry 9 }
  831.  
  832. pduOutletSwitchRebootDelay OBJECT-TYPE
  833.  SYNTAX Integer32(0..600)
  834.  MAX-ACCESS read-write
  835.  STATUS current
  836.  DESCRIPTION
  837.   "Seconds to wait before powering off the outlet, during
  838.   rebootAfterDelay(7) operation. Changing this value has no effect on
  839.   pending actions. See pduOutletSwitchControl for more info."
  840.  ::= { pduOutletSwitchEntry 10 }
  841.  
  842. pduOutletSwitchRebootHoldDelay OBJECT-TYPE
  843.  SYNTAX Integer32(0..600)
  844.  MAX-ACCESS read-write
  845.  STATUS current
  846.  DESCRIPTION
  847.   "Seconds to hold the outlet off, before powering on the outlet, during
  848.   rebootAfterDelay(7) operation. Changing this value has no effect on
  849.   pending actions. See pduOutletSwitchControl for more info."
  850.  ::= { pduOutletSwitchEntry 11 }
  851.  
  852. pduOutletSwitchPoaAction OBJECT-TYPE
  853.  SYNTAX INTEGER {
  854.    on(1),
  855.    off(2),
  856.    last(3)
  857.    }
  858.  MAX-ACCESS read-write
  859.  STATUS current
  860.  DESCRIPTION
  861.   "The outlet is set to this state during power-up. The action can be
  862.   have one the following values:
  863.   1 = Outlet will be turned on
  864.   2 = Outlet will stay off
  865.   3 = Outlet will be set to last known state"
  866.  ::= { pduOutletSwitchEntry 12 }
  867.  
  868. pduOutletSwitchPoaDelay OBJECT-TYPE
  869.  SYNTAX Integer32(0..600)
  870.  MAX-ACCESS read-write
  871.  STATUS current
  872.  DESCRIPTION
  873.   "Seconds to wait before setting the outlet to the
  874.   pduOutletSwitchPoaAction state. The delay starts at power-up."
  875.  ::= { pduOutletSwitchEntry 13 }
  876.  
  877. --###########################################################################################--
  878. --pduOutletMeterTable--
  879. --###########################################################################################--
  880.  
  881. pduOutletMeterTable OBJECT-TYPE
  882.  SYNTAX SEQUENCE OF PduOutletMeterEntry
  883.  MAX-ACCESS  not-accessible
  884.  STATUS current
  885.  DESCRIPTION
  886.   "Metering data for outlets that support this feature"
  887.  ::= { pdu 6 }
  888.  
  889. pduOutletMeterEntry OBJECT-TYPE
  890.  SYNTAX PduOutletMeterEntry
  891.  MAX-ACCESS  not-accessible
  892.  STATUS current
  893.  DESCRIPTION
  894.   "Entry in the pduOutletMeterTable table: each entry contains an index
  895.   and other sensor details"
  896.  INDEX { pduOutletMeterIndex }
  897.  ::= { pduOutletMeterTable 1 }
  898.  
  899. PduOutletMeterEntry ::= SEQUENCE {
  900.  pduOutletMeterIndex    Integer32,
  901.  pduOutletMeterName    SnmpAdminString,
  902.  pduOutletMeterLabel    SnmpAdminString,
  903.  pduOutletMeterVoltage    Gauge32,
  904.  pduOutletMeterCurrent    Gauge32,
  905.  pduOutletMeterRealPower    Gauge32,
  906.  pduOutletMeterApparentPower    Gauge32,
  907.  pduOutletMeterPowerFactor    Gauge32,
  908.  pduOutletMeterEnergy    Gauge32,
  909.  pduOutletMeterReset    INTEGER,
  910.  pduOutletCurrentCrestFactor    Gauge32
  911. }
  912.  
  913. pduOutletMeterIndex OBJECT-TYPE
  914.  SYNTAX Integer32(1..100)
  915.  MAX-ACCESS not-accessible
  916.  STATUS current
  917.  DESCRIPTION
  918.   "Table entry index value"
  919.  ::= { pduOutletMeterEntry 1 }
  920.  
  921. pduOutletMeterName OBJECT-TYPE
  922.  SYNTAX SnmpAdminString(SIZE (1..25))
  923.  MAX-ACCESS read-only
  924.  STATUS current
  925.  DESCRIPTION
  926.   "PDU outlet name (factory-assigned)"
  927.  ::= { pduOutletMeterEntry 2 }
  928.  
  929. pduOutletMeterLabel OBJECT-TYPE
  930.  SYNTAX SnmpAdminString(SIZE (0..25))
  931.  MAX-ACCESS read-write
  932.  STATUS current
  933.  DESCRIPTION
  934.   "PDU outlet label (user-defined)"
  935.  ::= { pduOutletMeterEntry 3 }
  936.  
  937. pduOutletMeterVoltage OBJECT-TYPE
  938.  SYNTAX Gauge32(0..3100)
  939.  UNITS "decivolts (rms)"
  940.  MAX-ACCESS read-only
  941.  STATUS current
  942.  DESCRIPTION
  943.   "PDU outlet voltage in tenths of a volt"
  944.  ::= { pduOutletMeterEntry 4 }
  945.  
  946. pduOutletMeterCurrent OBJECT-TYPE
  947.  SYNTAX Gauge32(0..9900)
  948.  UNITS "centiamps (rms)"
  949.  MAX-ACCESS read-only
  950.  STATUS current
  951.  DESCRIPTION
  952.   "PDU outlet current reading in hundredths of an amp"
  953.  ::= { pduOutletMeterEntry 8 }
  954.  
  955. pduOutletMeterRealPower OBJECT-TYPE
  956.  SYNTAX Gauge32(0..9999)
  957.  UNITS "watts"
  958.  MAX-ACCESS read-only
  959.  STATUS current
  960.  DESCRIPTION
  961.   "Real power for outlet in watts"
  962.  ::= { pduOutletMeterEntry 12 }
  963.  
  964. pduOutletMeterApparentPower OBJECT-TYPE
  965.  SYNTAX Gauge32(0..9999)
  966.  UNITS "volt-amps"
  967.  MAX-ACCESS read-only
  968.  STATUS current
  969.  DESCRIPTION
  970.   "Apparent power for outlet in volt-amps"
  971.  ::= { pduOutletMeterEntry 13 }
  972.  
  973. pduOutletMeterPowerFactor OBJECT-TYPE
  974.  SYNTAX Gauge32(0..100)
  975.  UNITS "%"
  976.  MAX-ACCESS read-only
  977.  STATUS current
  978.  DESCRIPTION
  979.   "Power factor for outlet"
  980.  ::= { pduOutletMeterEntry 14 }
  981.  
  982. pduOutletMeterEnergy OBJECT-TYPE
  983.  SYNTAX Gauge32(0..9999000)
  984.  UNITS "watt-hours"
  985.  MAX-ACCESS read-only
  986.  STATUS current
  987.  DESCRIPTION
  988.   "Accumulated energy for outlet in watt-hours"
  989.  ::= { pduOutletMeterEntry 15 }
  990.  
  991. pduOutletMeterReset OBJECT-TYPE
  992.  SYNTAX INTEGER {
  993.    resetEnergy(1),
  994.    none(8)
  995.    }
  996.  MAX-ACCESS read-write
  997.  STATUS current
  998.  DESCRIPTION
  999.   "Used to reset energy. If read, the value is none(8). It can be set to
  1000.   resetEnergy(1), which sets outlet energy to 0"
  1001.  ::= { pduOutletMeterEntry 16 }
  1002.  
  1003. pduOutletCurrentCrestFactor OBJECT-TYPE
  1004.  SYNTAX Gauge32(0..9999)
  1005.  MAX-ACCESS read-only
  1006.  STATUS current
  1007.  DESCRIPTION
  1008.   "Current crest factor for outlet, in hundredths"
  1009.  ::= { pduOutletMeterEntry 19 }
  1010.  
  1011. --###########################################################################################--
  1012. --tempSensorTable--
  1013. --###########################################################################################--
  1014.  
  1015. tempSensorTable OBJECT-TYPE
  1016.  SYNTAX SEQUENCE OF TempSensorEntry
  1017.  MAX-ACCESS  not-accessible
  1018.  STATUS current
  1019.  DESCRIPTION
  1020.   "Remote Temperature (RT) sensor"
  1021.  ::= { imd 4 }
  1022.  
  1023. tempSensorEntry OBJECT-TYPE
  1024.  SYNTAX TempSensorEntry
  1025.  MAX-ACCESS  not-accessible
  1026.  STATUS current
  1027.  DESCRIPTION
  1028.   "Entry in the tempSensorTable table: each entry contains an index
  1029.   and other sensor details"
  1030.  INDEX { tempSensorIndex }
  1031.  ::= { tempSensorTable 1 }
  1032.  
  1033. TempSensorEntry ::= SEQUENCE {
  1034.  tempSensorIndex    Integer32,
  1035.  tempSensorSerial    DisplayString,
  1036.  tempSensorLabel    SnmpAdminString,
  1037.  tempSensorAvail    Gauge32,
  1038.  tempSensorTemp    Integer32
  1039. }
  1040.  
  1041. tempSensorIndex OBJECT-TYPE
  1042.  SYNTAX Integer32(1..100)
  1043.  MAX-ACCESS not-accessible
  1044.  STATUS current
  1045.  DESCRIPTION
  1046.   "Table entry index value"
  1047.  ::= { tempSensorEntry 1 }
  1048.  
  1049. tempSensorSerial OBJECT-TYPE
  1050.  SYNTAX DisplayString
  1051.  MAX-ACCESS read-only
  1052.  STATUS current
  1053.  DESCRIPTION
  1054.   "Serial number"
  1055.  ::= { tempSensorEntry 2 }
  1056.  
  1057. tempSensorLabel OBJECT-TYPE
  1058.  SYNTAX SnmpAdminString(SIZE (0..25))
  1059.  MAX-ACCESS read-write
  1060.  STATUS current
  1061.  DESCRIPTION
  1062.   "User-defined label"
  1063.  ::= { tempSensorEntry 3 }
  1064.  
  1065. tempSensorAvail OBJECT-TYPE
  1066.  SYNTAX Gauge32
  1067.  MAX-ACCESS read-only
  1068.  STATUS current
  1069.  DESCRIPTION
  1070.   "Device availability:
  1071.   0 = Unavailable
  1072.   1 = Available
  1073.   2 = Partially Unavailable"
  1074.  ::= { tempSensorEntry 4 }
  1075.  
  1076. tempSensorTemp OBJECT-TYPE
  1077.  SYNTAX Integer32(-400..2540)
  1078.  UNITS "decidegrees"
  1079.  MAX-ACCESS read-only
  1080.  STATUS current
  1081.  DESCRIPTION
  1082.   "Temperature in tenths of a degree. Units are given by temperatureUnits
  1083.   field in deviceInfo."
  1084.  ::= { tempSensorEntry 5 }
  1085.  
  1086. --###########################################################################################--
  1087. --airFlowSensorTable--
  1088. --###########################################################################################--
  1089.  
  1090. airFlowSensorTable OBJECT-TYPE
  1091.  SYNTAX SEQUENCE OF AirFlowSensorEntry
  1092.  MAX-ACCESS  not-accessible
  1093.  STATUS current
  1094.  DESCRIPTION
  1095.   "Remote Airflow, Humidity, Temperature and Dewpoint (AFHT3) Sensor"
  1096.  ::= { imd 5 }
  1097.  
  1098. airFlowSensorEntry OBJECT-TYPE
  1099.  SYNTAX AirFlowSensorEntry
  1100.  MAX-ACCESS  not-accessible
  1101.  STATUS current
  1102.  DESCRIPTION
  1103.   "Entry in the airFlowSensorTable table: each entry contains an index
  1104.   and other sensor details"
  1105.  INDEX { airFlowSensorIndex }
  1106.  ::= { airFlowSensorTable 1 }
  1107.  
  1108. AirFlowSensorEntry ::= SEQUENCE {
  1109.  airFlowSensorIndex    Integer32,
  1110.  airFlowSensorSerial    DisplayString,
  1111.  airFlowSensorLabel    SnmpAdminString,
  1112.  airFlowSensorAvail    Gauge32,
  1113.  airFlowSensorTemp    Integer32,
  1114.  airFlowSensorFlow    Integer32,
  1115.  airFlowSensorHumidity    Integer32,
  1116.  airFlowSensorDewPoint    Integer32
  1117. }
  1118.  
  1119. airFlowSensorIndex OBJECT-TYPE
  1120.  SYNTAX Integer32(1..100)
  1121.  MAX-ACCESS not-accessible
  1122.  STATUS current
  1123.  DESCRIPTION
  1124.   "Table entry index value"
  1125.  ::= { airFlowSensorEntry 1 }
  1126.  
  1127. airFlowSensorSerial OBJECT-TYPE
  1128.  SYNTAX DisplayString
  1129.  MAX-ACCESS read-only
  1130.  STATUS current
  1131.  DESCRIPTION
  1132.   "Serial number"
  1133.  ::= { airFlowSensorEntry 2 }
  1134.  
  1135. airFlowSensorLabel OBJECT-TYPE
  1136.  SYNTAX SnmpAdminString(SIZE (0..25))
  1137.  MAX-ACCESS read-write
  1138.  STATUS current
  1139.  DESCRIPTION
  1140.   "User-defined label"
  1141.  ::= { airFlowSensorEntry 3 }
  1142.  
  1143. airFlowSensorAvail OBJECT-TYPE
  1144.  SYNTAX Gauge32
  1145.  MAX-ACCESS read-only
  1146.  STATUS current
  1147.  DESCRIPTION
  1148.   "Device availability:
  1149.   0 = Unavailable
  1150.   1 = Available
  1151.   2 = Partially Unavailable"
  1152.  ::= { airFlowSensorEntry 4 }
  1153.  
  1154. airFlowSensorTemp OBJECT-TYPE
  1155.  SYNTAX Integer32(-400..2540)
  1156.  UNITS "decidegrees"
  1157.  MAX-ACCESS read-only
  1158.  STATUS current
  1159.  DESCRIPTION
  1160.   "Temperature reading in tenths of a degree. Units are given by
  1161.   temperatureUnits field in deviceInfo."
  1162.  ::= { airFlowSensorEntry 5 }
  1163.  
  1164. airFlowSensorFlow OBJECT-TYPE
  1165.  SYNTAX Integer32(0..100)
  1166.  MAX-ACCESS read-only
  1167.  STATUS current
  1168.  DESCRIPTION
  1169.   "Airflow reading. Still air will be less than 20, while rushing air
  1170.   will be around 100."
  1171.  ::= { airFlowSensorEntry 6 }
  1172.  
  1173. airFlowSensorHumidity OBJECT-TYPE
  1174.  SYNTAX Integer32(0..100)
  1175.  UNITS "%"
  1176.  MAX-ACCESS read-only
  1177.  STATUS current
  1178.  DESCRIPTION
  1179.   "Humidity reading"
  1180.  ::= { airFlowSensorEntry 7 }
  1181.  
  1182. airFlowSensorDewPoint OBJECT-TYPE
  1183.  SYNTAX Integer32(-400..2540)
  1184.  UNITS "decidegrees"
  1185.  MAX-ACCESS read-only
  1186.  STATUS current
  1187.  DESCRIPTION
  1188.   "Dewpoint reading in tenths of a degree. Units are given by
  1189.   temperatureUnits field in deviceInfo."
  1190.  ::= { airFlowSensorEntry 8 }
  1191.  
  1192. --###########################################################################################--
  1193. --t3hdSensorTable--
  1194. --###########################################################################################--
  1195.  
  1196. t3hdSensorTable OBJECT-TYPE
  1197.  SYNTAX SEQUENCE OF T3hdSensorEntry
  1198.  MAX-ACCESS  not-accessible
  1199.  STATUS current
  1200.  DESCRIPTION
  1201.   "Remote Temperature x 3, Humidity and Dewpoint Sensor"
  1202.  ::= { imd 8 }
  1203.  
  1204. t3hdSensorEntry OBJECT-TYPE
  1205.  SYNTAX T3hdSensorEntry
  1206.  MAX-ACCESS  not-accessible
  1207.  STATUS current
  1208.  DESCRIPTION
  1209.   "Entry in the t3hdSensorTable table: each entry contains an index
  1210.   and other sensor details"
  1211.  INDEX { t3hdSensorIndex }
  1212.  ::= { t3hdSensorTable 1 }
  1213.  
  1214. T3hdSensorEntry ::= SEQUENCE {
  1215.  t3hdSensorIndex    Integer32,
  1216.  t3hdSensorSerial    DisplayString,
  1217.  t3hdSensorLabel    SnmpAdminString,
  1218.  t3hdSensorAvail    Gauge32,
  1219.  t3hdSensorIntLabel    SnmpAdminString,
  1220.  t3hdSensorIntTemp    Integer32,
  1221.  t3hdSensorIntHumidity    Integer32,
  1222.  t3hdSensorIntDewPoint    Integer32,
  1223.  t3hdSensorExtAAvail    Gauge32,
  1224.  t3hdSensorExtALabel    SnmpAdminString,
  1225.  t3hdSensorExtATemp    Integer32,
  1226.  t3hdSensorExtBAvail    Gauge32,
  1227.  t3hdSensorExtBLabel    SnmpAdminString,
  1228.  t3hdSensorExtBTemp    Integer32
  1229. }
  1230.  
  1231. t3hdSensorIndex OBJECT-TYPE
  1232.  SYNTAX Integer32(1..100)
  1233.  MAX-ACCESS not-accessible
  1234.  STATUS current
  1235.  DESCRIPTION
  1236.   "Table entry index value"
  1237.  ::= { t3hdSensorEntry 1 }
  1238.  
  1239. t3hdSensorSerial OBJECT-TYPE
  1240.  SYNTAX DisplayString
  1241.  MAX-ACCESS read-only
  1242.  STATUS current
  1243.  DESCRIPTION
  1244.   "Serial number"
  1245.  ::= { t3hdSensorEntry 2 }
  1246.  
  1247. t3hdSensorLabel OBJECT-TYPE
  1248.  SYNTAX SnmpAdminString(SIZE (0..25))
  1249.  MAX-ACCESS read-write
  1250.  STATUS current
  1251.  DESCRIPTION
  1252.   "User-defined label"
  1253.  ::= { t3hdSensorEntry 3 }
  1254.  
  1255. t3hdSensorAvail OBJECT-TYPE
  1256.  SYNTAX Gauge32
  1257.  MAX-ACCESS read-only
  1258.  STATUS current
  1259.  DESCRIPTION
  1260.   "Device availability:
  1261.   0 = Unavailable
  1262.   1 = Available
  1263.   2 = Partially Unavailable"
  1264.  ::= { t3hdSensorEntry 4 }
  1265.  
  1266. t3hdSensorIntLabel OBJECT-TYPE
  1267.  SYNTAX SnmpAdminString(SIZE (0..25))
  1268.  MAX-ACCESS read-write
  1269.  STATUS current
  1270.  DESCRIPTION
  1271.   "Internal label (user-defined)"
  1272.  ::= { t3hdSensorEntry 5 }
  1273.  
  1274. t3hdSensorIntTemp OBJECT-TYPE
  1275.  SYNTAX Integer32(-400..2540)
  1276.  UNITS "decidegrees"
  1277.  MAX-ACCESS read-only
  1278.  STATUS current
  1279.  DESCRIPTION
  1280.   "Internal temperature in tenths of a degree. Units are given by
  1281.   temperatureUnits field in deviceInfo."
  1282.  ::= { t3hdSensorEntry 6 }
  1283.  
  1284. t3hdSensorIntHumidity OBJECT-TYPE
  1285.  SYNTAX Integer32(0..100)
  1286.  UNITS "%"
  1287.  MAX-ACCESS read-only
  1288.  STATUS current
  1289.  DESCRIPTION
  1290.   "Internal humidity"
  1291.  ::= { t3hdSensorEntry 7 }
  1292.  
  1293. t3hdSensorIntDewPoint OBJECT-TYPE
  1294.  SYNTAX Integer32(-400..2540)
  1295.  UNITS "decidegrees"
  1296.  MAX-ACCESS read-only
  1297.  STATUS current
  1298.  DESCRIPTION
  1299.   "Internal dewpoint in tenths of a degree. Units are given by
  1300.   temperatureUnits field in deviceInfo."
  1301.  ::= { t3hdSensorEntry 8 }
  1302.  
  1303. t3hdSensorExtAAvail OBJECT-TYPE
  1304.  SYNTAX Gauge32
  1305.  MAX-ACCESS read-only
  1306.  STATUS current
  1307.  DESCRIPTION
  1308.   "External A status:
  1309.   0 = Unavailable
  1310.   1 = Available"
  1311.  ::= { t3hdSensorEntry 9 }
  1312.  
  1313. t3hdSensorExtALabel OBJECT-TYPE
  1314.  SYNTAX SnmpAdminString(SIZE (0..25))
  1315.  MAX-ACCESS read-write
  1316.  STATUS current
  1317.  DESCRIPTION
  1318.   "External A label (user-defined)"
  1319.  ::= { t3hdSensorEntry 10 }
  1320.  
  1321. t3hdSensorExtATemp OBJECT-TYPE
  1322.  SYNTAX Integer32(-400..2540)
  1323.  UNITS "decidegrees"
  1324.  MAX-ACCESS read-only
  1325.  STATUS current
  1326.  DESCRIPTION
  1327.   "External A temperature in tenths of a degree. Units are given by
  1328.   temperatureUnits field in deviceInfo."
  1329.  ::= { t3hdSensorEntry 11 }
  1330.  
  1331. t3hdSensorExtBAvail OBJECT-TYPE
  1332.  SYNTAX Gauge32
  1333.  MAX-ACCESS read-only
  1334.  STATUS current
  1335.  DESCRIPTION
  1336.   "External B status:
  1337.   0 = Unavailable
  1338.   1 = Available"
  1339.  ::= { t3hdSensorEntry 12 }
  1340.  
  1341. t3hdSensorExtBLabel OBJECT-TYPE
  1342.  SYNTAX SnmpAdminString(SIZE (0..25))
  1343.  MAX-ACCESS read-write
  1344.  STATUS current
  1345.  DESCRIPTION
  1346.   "External B label (user-defined)"
  1347.  ::= { t3hdSensorEntry 13 }
  1348.  
  1349. t3hdSensorExtBTemp OBJECT-TYPE
  1350.  SYNTAX Integer32(-400..2540)
  1351.  UNITS "decidegrees"
  1352.  MAX-ACCESS read-only
  1353.  STATUS current
  1354.  DESCRIPTION
  1355.   "External B temperature in tenths of a degree. Units are given by
  1356.   temperatureUnits field in deviceInfo."
  1357.  ::= { t3hdSensorEntry 14 }
  1358.  
  1359. --###########################################################################################--
  1360. --thdSensorTable--
  1361. --###########################################################################################--
  1362.  
  1363. thdSensorTable OBJECT-TYPE
  1364.  SYNTAX SEQUENCE OF ThdSensorEntry
  1365.  MAX-ACCESS  not-accessible
  1366.  STATUS current
  1367.  DESCRIPTION
  1368.   "Remote Temperature, Humidity, and Dewpoint (THD) Sensor"
  1369.  ::= { imd 9 }
  1370.  
  1371. thdSensorEntry OBJECT-TYPE
  1372.  SYNTAX ThdSensorEntry
  1373.  MAX-ACCESS  not-accessible
  1374.  STATUS current
  1375.  DESCRIPTION
  1376.   "Entry in the thdSensorTable table: each entry contains an index
  1377.   and other sensor details"
  1378.  INDEX { thdSensorIndex }
  1379.  ::= { thdSensorTable 1 }
  1380.  
  1381. ThdSensorEntry ::= SEQUENCE {
  1382.  thdSensorIndex    Integer32,
  1383.  thdSensorSerial    DisplayString,
  1384.  thdSensorLabel    SnmpAdminString,
  1385.  thdSensorAvail    Gauge32,
  1386.  thdSensorTemp    Integer32,
  1387.  thdSensorHumidity    Integer32,
  1388.  thdSensorDewPoint    Integer32
  1389. }
  1390.  
  1391. thdSensorIndex OBJECT-TYPE
  1392.  SYNTAX Integer32(1..100)
  1393.  MAX-ACCESS not-accessible
  1394.  STATUS current
  1395.  DESCRIPTION
  1396.   "Table entry index value"
  1397.  ::= { thdSensorEntry 1 }
  1398.  
  1399. thdSensorSerial OBJECT-TYPE
  1400.  SYNTAX DisplayString
  1401.  MAX-ACCESS read-only
  1402.  STATUS current
  1403.  DESCRIPTION
  1404.   "Serial number"
  1405.  ::= { thdSensorEntry 2 }
  1406.  
  1407. thdSensorLabel OBJECT-TYPE
  1408.  SYNTAX SnmpAdminString(SIZE (0..25))
  1409.  MAX-ACCESS read-write
  1410.  STATUS current
  1411.  DESCRIPTION
  1412.   "User-defined label"
  1413.  ::= { thdSensorEntry 3 }
  1414.  
  1415. thdSensorAvail OBJECT-TYPE
  1416.  SYNTAX Gauge32
  1417.  MAX-ACCESS read-only
  1418.  STATUS current
  1419.  DESCRIPTION
  1420.   "Device availability:
  1421.   0 = Unavailable
  1422.   1 = Available
  1423.   2 = Partially Unavailable"
  1424.  ::= { thdSensorEntry 4 }
  1425.  
  1426. thdSensorTemp OBJECT-TYPE
  1427.  SYNTAX Integer32(-400..2540)
  1428.  UNITS "decidegrees"
  1429.  MAX-ACCESS read-only
  1430.  STATUS current
  1431.  DESCRIPTION
  1432.   "Temperature value in tenths of a degree. Units are given by
  1433.   temperatureUnits field in deviceInfo."
  1434.  ::= { thdSensorEntry 5 }
  1435.  
  1436. thdSensorHumidity OBJECT-TYPE
  1437.  SYNTAX Integer32(0..100)
  1438.  UNITS "%"
  1439.  MAX-ACCESS read-only
  1440.  STATUS current
  1441.  DESCRIPTION
  1442.   "Humidity value"
  1443.  ::= { thdSensorEntry 6 }
  1444.  
  1445. thdSensorDewPoint OBJECT-TYPE
  1446.  SYNTAX Integer32(-400..2540)
  1447.  UNITS "decidegrees"
  1448.  MAX-ACCESS read-only
  1449.  STATUS current
  1450.  DESCRIPTION
  1451.   "Dewpoint value in tenths of a degree. Units are given by
  1452.   temperatureUnits field in deviceInfo."
  1453.  ::= { thdSensorEntry 7 }
  1454.  
  1455. --###########################################################################################--
  1456. --a2dSensorTable--
  1457. --###########################################################################################--
  1458.  
  1459. a2dSensorTable OBJECT-TYPE
  1460.  SYNTAX SEQUENCE OF A2dSensorEntry
  1461.  MAX-ACCESS  not-accessible
  1462.  STATUS current
  1463.  DESCRIPTION
  1464.   "Analog measurement (A2D) sensor (voltage, current, or dry-contact)"
  1465.  ::= { imd 11 }
  1466.  
  1467. a2dSensorEntry OBJECT-TYPE
  1468.  SYNTAX A2dSensorEntry
  1469.  MAX-ACCESS  not-accessible
  1470.  STATUS current
  1471.  DESCRIPTION
  1472.   "Entry in the a2dSensorTable table: each entry contains an index
  1473.   and other sensor details"
  1474.  INDEX { a2dSensorIndex }
  1475.  ::= { a2dSensorTable 1 }
  1476.  
  1477. A2dSensorEntry ::= SEQUENCE {
  1478.  a2dSensorIndex    Integer32,
  1479.  a2dSensorSerial    DisplayString,
  1480.  a2dSensorLabel    SnmpAdminString,
  1481.  a2dSensorAvail    Gauge32,
  1482.  a2dSensorValue    Integer32,
  1483.  a2dSensorDisplayValue    SnmpAdminString,
  1484.  a2dSensorMode    INTEGER,
  1485.  a2dSensorUnits    SnmpAdminString,
  1486.  a2dSensorMin    Integer32,
  1487.  a2dSensorMax    Integer32,
  1488.  a2dSensorLowLabel    SnmpAdminString,
  1489.  a2dSensorHighLabel    SnmpAdminString,
  1490.  a2dSensorAnalogLabel    SnmpAdminString
  1491. }
  1492.  
  1493. a2dSensorIndex OBJECT-TYPE
  1494.  SYNTAX Integer32(1..100)
  1495.  MAX-ACCESS not-accessible
  1496.  STATUS current
  1497.  DESCRIPTION
  1498.   "Table entry index value"
  1499.  ::= { a2dSensorEntry 1 }
  1500.  
  1501. a2dSensorSerial OBJECT-TYPE
  1502.  SYNTAX DisplayString
  1503.  MAX-ACCESS read-only
  1504.  STATUS current
  1505.  DESCRIPTION
  1506.   "Serial number"
  1507.  ::= { a2dSensorEntry 2 }
  1508.  
  1509. a2dSensorLabel OBJECT-TYPE
  1510.  SYNTAX SnmpAdminString(SIZE (0..25))
  1511.  MAX-ACCESS read-write
  1512.  STATUS current
  1513.  DESCRIPTION
  1514.   "User-defined label"
  1515.  ::= { a2dSensorEntry 3 }
  1516.  
  1517. a2dSensorAvail OBJECT-TYPE
  1518.  SYNTAX Gauge32
  1519.  MAX-ACCESS read-only
  1520.  STATUS current
  1521.  DESCRIPTION
  1522.   "Device availability:
  1523.   0 = Unavailable
  1524.   1 = Available
  1525.   2 = Partially Unavailable"
  1526.  ::= { a2dSensorEntry 4 }
  1527.  
  1528. a2dSensorValue OBJECT-TYPE
  1529.  SYNTAX Integer32(-1000000..1000000)
  1530.  MAX-ACCESS read-only
  1531.  STATUS current
  1532.  DESCRIPTION
  1533.   "Analog measurement value, within either a user-defined or preset
  1534.   range, depending on a2dSensorMode."
  1535.  ::= { a2dSensorEntry 5 }
  1536.  
  1537. a2dSensorDisplayValue OBJECT-TYPE
  1538.  SYNTAX SnmpAdminString(SIZE (0..25))
  1539.  MAX-ACCESS read-only
  1540.  STATUS current
  1541.  DESCRIPTION
  1542.   "For current/voltage modes, the analog value is given as a string. In
  1543.   binary modes, the value is either a2dSensorLowLabel or
  1544.   a2dSensorHighLabel, based on a2dSensorValue."
  1545.  ::= { a2dSensorEntry 6 }
  1546.  
  1547. a2dSensorMode OBJECT-TYPE
  1548.  SYNTAX INTEGER {
  1549.    door(1),
  1550.    powerFailure(2),
  1551.    flood(3),
  1552.    wscLeak(4),
  1553.    wscFault(5),
  1554.    smoke(6),
  1555.    ivsNegGnd(7),
  1556.    ivsPosGnd(8),
  1557.    customVoltage(9),
  1558.    customBinary(10),
  1559.    customCurrent(11)
  1560.    }
  1561.  MAX-ACCESS read-write
  1562.  STATUS current
  1563.  DESCRIPTION
  1564.   "Binary modes have two states represented by the values 0 (low) or 1
  1565.   (high). These correspond to a2dSensorLowLabel and a2dSensorHighLabel.
  1566.   Current and voltage modes provide a scaled value from a2dSensorMin to
  1567.   a2dSensorMax.
  1568.   Analog modes:
  1569.   1 = Door (binary)
  1570.   2 = Power failure (binary)
  1571.   3 = Flood (binary)
  1572.   4 = Water-sensing cable leak (binary)
  1573.   5 = Water-sensing cable fault (binary)
  1574.   6 = Smoke alarm (binary)
  1575.   7 = Isolated voltage negative ground (voltage)
  1576.   8 = Isolated voltage positive ground (voltage)
  1577.   9 = Custom voltage (voltage)
  1578.   10 = Custom binary (binary)
  1579.   11 = Custom current (current)"
  1580.  ::= { a2dSensorEntry 7 }
  1581.  
  1582. a2dSensorUnits OBJECT-TYPE
  1583.  SYNTAX SnmpAdminString(SIZE (0..7))
  1584.  MAX-ACCESS read-write
  1585.  STATUS current
  1586.  DESCRIPTION
  1587.   "The units for the analog value. If a2dSensorMode is customVoltage(9)
  1588.   or customCurrent(11), then this field has a user-defined value.
  1589.   Otherwise, the value is fixed, based on mode."
  1590.  ::= { a2dSensorEntry 8 }
  1591.  
  1592. a2dSensorMin OBJECT-TYPE
  1593.  SYNTAX Integer32(-1000000..1000000)
  1594.  MAX-ACCESS read-write
  1595.  STATUS current
  1596.  DESCRIPTION
  1597.   "Minimum analog value, given as an integer. The analog measurement is
  1598.   scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
  1599.   customVoltage(9) or customCurrent(11), then this field has a user-
  1600.   defined value. Otherwise, the value is fixed, based on mode."
  1601.  ::= { a2dSensorEntry 9 }
  1602.  
  1603. a2dSensorMax OBJECT-TYPE
  1604.  SYNTAX Integer32(-1000000..1000000)
  1605.  MAX-ACCESS read-write
  1606.  STATUS current
  1607.  DESCRIPTION
  1608.   "Maximum analog value, given as an integer. The analog measurement is
  1609.   scaled to the range a2dSensorMin to a2dSensorMax. If a2dSensorMode is
  1610.   customVoltage(9) or customCurrent(11), then this field has a user-
  1611.   defined value. Otherwise, the value is fixed, based on mode."
  1612.  ::= { a2dSensorEntry 10 }
  1613.  
  1614. a2dSensorLowLabel OBJECT-TYPE
  1615.  SYNTAX SnmpAdminString(SIZE (0..25))
  1616.  MAX-ACCESS read-write
  1617.  STATUS current
  1618.  DESCRIPTION
  1619.   "Label for 0 (low) binary value. This field is only applicable if
  1620.   a2dSensorMode is one of the binary modes. If a2dSensorMode is
  1621.   customBinary(10), then this field is user-defined. Otherwise, it has a
  1622.   pre-defined value based on the mode."
  1623.  ::= { a2dSensorEntry 11 }
  1624.  
  1625. a2dSensorHighLabel OBJECT-TYPE
  1626.  SYNTAX SnmpAdminString(SIZE (0..25))
  1627.  MAX-ACCESS read-write
  1628.  STATUS current
  1629.  DESCRIPTION
  1630.   "Label for 1 (high) binary value. The field is only applicable if
  1631.   a2dSensorMode is one of the binary modes. If a2dSensorMode is
  1632.   customBinary(10), then this field is user-defined. Otherwise, it has a
  1633.   pre-defined value based on the mode."
  1634.  ::= { a2dSensorEntry 12 }
  1635.  
  1636. a2dSensorAnalogLabel OBJECT-TYPE
  1637.  SYNTAX SnmpAdminString(SIZE (0..25))
  1638.  MAX-ACCESS read-write
  1639.  STATUS current
  1640.  DESCRIPTION
  1641.   "Label for the analog measurement"
  1642.  ::= { a2dSensorEntry 13 }
  1643.  
  1644. --###########################################################################################--
  1645. --humiditySensorTable--
  1646. --###########################################################################################--
  1647.  
  1648. humiditySensorTable OBJECT-TYPE
  1649.  SYNTAX SEQUENCE OF HumiditySensorEntry
  1650.  MAX-ACCESS  not-accessible
  1651.  STATUS current
  1652.  DESCRIPTION
  1653.   "Remote humidity sensor"
  1654.  ::= { imd 12 }
  1655.  
  1656. humiditySensorEntry OBJECT-TYPE
  1657.  SYNTAX HumiditySensorEntry
  1658.  MAX-ACCESS  not-accessible
  1659.  STATUS current
  1660.  DESCRIPTION
  1661.   "Entry in the humiditySensorTable table: each entry contains an index
  1662.   and other sensor details"
  1663.  INDEX { humiditySensorIndex }
  1664.  ::= { humiditySensorTable 1 }
  1665.  
  1666. HumiditySensorEntry ::= SEQUENCE {
  1667.  humiditySensorIndex    Integer32,
  1668.  humiditySensorSerial    DisplayString,
  1669.  humiditySensorLabel    SnmpAdminString,
  1670.  humiditySensorAvail    Gauge32,
  1671.  humiditySensorValue    Integer32
  1672. }
  1673.  
  1674. humiditySensorIndex OBJECT-TYPE
  1675.  SYNTAX Integer32(1..100)
  1676.  MAX-ACCESS not-accessible
  1677.  STATUS current
  1678.  DESCRIPTION
  1679.   "Table entry index value"
  1680.  ::= { humiditySensorEntry 1 }
  1681.  
  1682. humiditySensorSerial OBJECT-TYPE
  1683.  SYNTAX DisplayString
  1684.  MAX-ACCESS read-only
  1685.  STATUS current
  1686.  DESCRIPTION
  1687.   "Serial number"
  1688.  ::= { humiditySensorEntry 2 }
  1689.  
  1690. humiditySensorLabel OBJECT-TYPE
  1691.  SYNTAX SnmpAdminString(SIZE (0..25))
  1692.  MAX-ACCESS read-write
  1693.  STATUS current
  1694.  DESCRIPTION
  1695.   "User-defined label"
  1696.  ::= { humiditySensorEntry 3 }
  1697.  
  1698. humiditySensorAvail OBJECT-TYPE
  1699.  SYNTAX Gauge32
  1700.  MAX-ACCESS read-only
  1701.  STATUS current
  1702.  DESCRIPTION
  1703.   "Device availability:
  1704.   0 = Unavailable
  1705.   1 = Available
  1706.   2 = Partially Unavailable"
  1707.  ::= { humiditySensorEntry 4 }
  1708.  
  1709. humiditySensorValue OBJECT-TYPE
  1710.  SYNTAX Integer32(0..100)
  1711.  MAX-ACCESS read-only
  1712.  STATUS current
  1713.  DESCRIPTION
  1714.   "Humidity value"
  1715.  ::= { humiditySensorEntry 5 }
  1716.  
  1717. --###########################################################################################--
  1718. --sn2dSensorTable--
  1719. --###########################################################################################--
  1720.  
  1721. sn2dSensorTable OBJECT-TYPE
  1722.  SYNTAX SEQUENCE OF Sn2dSensorEntry
  1723.  MAX-ACCESS  not-accessible
  1724.  STATUS current
  1725.  DESCRIPTION
  1726.   "2 Door Switch Sensor (SN-2D)"
  1727.  ::= { imd 13 }
  1728.  
  1729. sn2dSensorEntry OBJECT-TYPE
  1730.  SYNTAX Sn2dSensorEntry
  1731.  MAX-ACCESS  not-accessible
  1732.  STATUS current
  1733.  DESCRIPTION
  1734.   "Entry in the sn2dSensorTable table: each entry contains an index
  1735.   and other sensor details"
  1736.  INDEX { sn2dSensorIndex }
  1737.  ::= { sn2dSensorTable 1 }
  1738.  
  1739. Sn2dSensorEntry ::= SEQUENCE {
  1740.  sn2dSensorIndex    Integer32,
  1741.  sn2dSensorSerial    DisplayString,
  1742.  sn2dSensorLabel    SnmpAdminString,
  1743.  sn2dSensorAvail    Gauge32,
  1744.  sn2dSensorDoor1Label    SnmpAdminString,
  1745.  sn2dSensorDoor1State    INTEGER,
  1746.  sn2dSensorDoor1DisplayState    SnmpAdminString,
  1747.  sn2dSensorDoor2Label    SnmpAdminString,
  1748.  sn2dSensorDoor2State    INTEGER,
  1749.  sn2dSensorDoor2DisplayState    SnmpAdminString
  1750. }
  1751.  
  1752. sn2dSensorIndex OBJECT-TYPE
  1753.  SYNTAX Integer32(1..100)
  1754.  MAX-ACCESS not-accessible
  1755.  STATUS current
  1756.  DESCRIPTION
  1757.   "Table entry index value"
  1758.  ::= { sn2dSensorEntry 1 }
  1759.  
  1760. sn2dSensorSerial OBJECT-TYPE
  1761.  SYNTAX DisplayString
  1762.  MAX-ACCESS read-only
  1763.  STATUS current
  1764.  DESCRIPTION
  1765.   "Serial number"
  1766.  ::= { sn2dSensorEntry 2 }
  1767.  
  1768. sn2dSensorLabel OBJECT-TYPE
  1769.  SYNTAX SnmpAdminString(SIZE (0..25))
  1770.  MAX-ACCESS read-write
  1771.  STATUS current
  1772.  DESCRIPTION
  1773.   "User-defined label"
  1774.  ::= { sn2dSensorEntry 3 }
  1775.  
  1776. sn2dSensorAvail OBJECT-TYPE
  1777.  SYNTAX Gauge32
  1778.  MAX-ACCESS read-only
  1779.  STATUS current
  1780.  DESCRIPTION
  1781.   "Device availability:
  1782.   0 = Unavailable
  1783.   1 = Available
  1784.   2 = Partially Unavailable"
  1785.  ::= { sn2dSensorEntry 4 }
  1786.  
  1787. sn2dSensorDoor1Label OBJECT-TYPE
  1788.  SYNTAX SnmpAdminString(SIZE (0..25))
  1789.  MAX-ACCESS read-write
  1790.  STATUS current
  1791.  DESCRIPTION
  1792.   "Door switch 1 label"
  1793.  ::= { sn2dSensorEntry 5 }
  1794.  
  1795. sn2dSensorDoor1State OBJECT-TYPE
  1796.  SYNTAX INTEGER {
  1797.    open(1),
  1798.    closed(2)
  1799.    }
  1800.  MAX-ACCESS read-only
  1801.  STATUS current
  1802.  DESCRIPTION
  1803.   "Door switch 1 state:
  1804.   1 = open
  1805.   2 = closed"
  1806.  ::= { sn2dSensorEntry 6 }
  1807.  
  1808. sn2dSensorDoor1DisplayState OBJECT-TYPE
  1809.  SYNTAX SnmpAdminString(SIZE (0..25))
  1810.  MAX-ACCESS read-only
  1811.  STATUS current
  1812.  DESCRIPTION
  1813.   "Door switch 1 state given as a string"
  1814.  ::= { sn2dSensorEntry 7 }
  1815.  
  1816. sn2dSensorDoor2Label OBJECT-TYPE
  1817.  SYNTAX SnmpAdminString(SIZE (0..25))
  1818.  MAX-ACCESS read-write
  1819.  STATUS current
  1820.  DESCRIPTION
  1821.   "Door switch 2 label"
  1822.  ::= { sn2dSensorEntry 8 }
  1823.  
  1824. sn2dSensorDoor2State OBJECT-TYPE
  1825.  SYNTAX INTEGER {
  1826.    open(1),
  1827.    closed(2)
  1828.    }
  1829.  MAX-ACCESS read-only
  1830.  STATUS current
  1831.  DESCRIPTION
  1832.   "Door switch 2 state:
  1833.   1 = open
  1834.   2 = closed"
  1835.  ::= { sn2dSensorEntry 9 }
  1836.  
  1837. sn2dSensorDoor2DisplayState OBJECT-TYPE
  1838.  SYNTAX SnmpAdminString(SIZE (0..25))
  1839.  MAX-ACCESS read-only
  1840.  STATUS current
  1841.  DESCRIPTION
  1842.   "Door switch 2 state given as a string"
  1843.  ::= { sn2dSensorEntry 10 }
  1844.  
  1845. --###########################################################################################--
  1846. --cooling--
  1847. --###########################################################################################--
  1848.  
  1849. cooling OBJECT IDENTIFIER ::= { imd 30 }
  1850.  
  1851. --###########################################################################################--
  1852. --vrc--
  1853. --###########################################################################################--
  1854.  
  1855. vrc OBJECT IDENTIFIER ::= { cooling 1 }
  1856.  
  1857. --###########################################################################################--
  1858. --vrcMainTable--
  1859. --###########################################################################################--
  1860.  
  1861. vrcMainTable OBJECT-TYPE
  1862.  SYNTAX SEQUENCE OF VrcMainEntry
  1863.  MAX-ACCESS  not-accessible
  1864.  STATUS current
  1865.  DESCRIPTION
  1866.   "Table that contains general VRC information"
  1867.  ::= { vrc 1 }
  1868.  
  1869. vrcMainEntry OBJECT-TYPE
  1870.  SYNTAX VrcMainEntry
  1871.  MAX-ACCESS  not-accessible
  1872.  STATUS current
  1873.  DESCRIPTION
  1874.   "Entry in the vrcMainTable: each entry represents a VRC device"
  1875.  INDEX { vrcMainIndex }
  1876.  ::= { vrcMainTable 1 }
  1877.  
  1878. VrcMainEntry ::= SEQUENCE {
  1879.  vrcMainIndex    Integer32,
  1880.  vrcMainSerial    DisplayString,
  1881.  vrcMainName    SnmpAdminString,
  1882.  vrcMainLabel    SnmpAdminString,
  1883.  vrcMainAvail    Gauge32
  1884. }
  1885.  
  1886. vrcMainIndex OBJECT-TYPE
  1887.  SYNTAX Integer32(1..100)
  1888.  MAX-ACCESS not-accessible
  1889.  STATUS current
  1890.  DESCRIPTION
  1891.   "Unique id for each entry in the table"
  1892.  ::= { vrcMainEntry 1 }
  1893.  
  1894. vrcMainSerial OBJECT-TYPE
  1895.  SYNTAX DisplayString
  1896.  MAX-ACCESS read-only
  1897.  STATUS current
  1898.  DESCRIPTION
  1899.   "Serial number"
  1900.  ::= { vrcMainEntry 2 }
  1901.  
  1902. vrcMainName OBJECT-TYPE
  1903.  SYNTAX SnmpAdminString(SIZE (1..25))
  1904.  MAX-ACCESS read-only
  1905.  STATUS current
  1906.  DESCRIPTION
  1907.   "VRC name (factory-assigned)"
  1908.  ::= { vrcMainEntry 3 }
  1909.  
  1910. vrcMainLabel OBJECT-TYPE
  1911.  SYNTAX SnmpAdminString(SIZE (0..25))
  1912.  MAX-ACCESS read-write
  1913.  STATUS current
  1914.  DESCRIPTION
  1915.   "VRC label (user-defined)"
  1916.  ::= { vrcMainEntry 4 }
  1917.  
  1918. vrcMainAvail OBJECT-TYPE
  1919.  SYNTAX Gauge32
  1920.  MAX-ACCESS read-only
  1921.  STATUS current
  1922.  DESCRIPTION
  1923.   "Device availability:
  1924.   0 = Unavailable
  1925.   1 = Available
  1926.   2 = Partially Unavailable"
  1927.  ::= { vrcMainEntry 5 }
  1928.  
  1929. --###########################################################################################--
  1930. --vrcMainPtTable--
  1931. --###########################################################################################--
  1932.  
  1933. vrcMainPtTable OBJECT-TYPE
  1934.  SYNTAX SEQUENCE OF VrcMainPtEntry
  1935.  MAX-ACCESS  not-accessible
  1936.  STATUS current
  1937.  DESCRIPTION
  1938.   "Table that contains general VRC status"
  1939.  ::= { vrc 2 }
  1940.  
  1941. vrcMainPtEntry OBJECT-TYPE
  1942.  SYNTAX VrcMainPtEntry
  1943.  MAX-ACCESS  not-accessible
  1944.  STATUS current
  1945.  DESCRIPTION
  1946.   "Entry in the vrcMainPtTable: each entry contains status data for a VRC
  1947.   device"
  1948.  INDEX { vrcMainPtIndex }
  1949.  ::= { vrcMainPtTable 1 }
  1950.  
  1951. VrcMainPtEntry ::= SEQUENCE {
  1952.  vrcMainPtIndex    Integer32,
  1953.  vrcMainPtRunState    INTEGER,
  1954.  vrcMainPtEevOpened    Integer32,
  1955.  vrcMainPtAlarmNumbers    Integer32,
  1956.  vrcMainPtHistoryAlarmNumbers    Integer32,
  1957.  vrcMainPtHpAbnRecordCnt    Integer32,
  1958.  vrcMainPtMonitorBaudrate    INTEGER,
  1959.  vrcMainPtMonitorAddress    Integer32,
  1960.  vrcMainPtLp    TruthValue,
  1961.  vrcMainPtFilterMaintRemind    TruthValue,
  1962.  vrcMainPtCoolingFlag    TruthValue,
  1963.  vrcMainPtFirstOnFlag    TruthValue,
  1964.  vrcMainPtNewAlarmFlag    TruthValue,
  1965.  vrcMainPtComAlarmOutState    TruthValue,
  1966.  vrcMainPtHighWaterInput    TruthValue,
  1967.  vrcMainPtHighWaterAlarm    TruthValue,
  1968.  vrcMainPtWaterUnderFloorAlarm    TruthValue,
  1969.  vrcMainPtSwShutDownStatus    TruthValue,
  1970.  vrcMainPtRemoteShutdown    TruthValue,
  1971.  vrcMainPtRemoteShutDownFlag    TruthValue,
  1972.  vrcMainPtRemoteShutDownAlarm    TruthValue,
  1973.  vrcMainPtHmiShutDownFlag    TruthValue,
  1974.  vrcMainPtLpAlarm    TruthValue,
  1975.  vrcMainPtHpAlarm    TruthValue,
  1976.  vrcMainPtLpFreqAlarm    TruthValue,
  1977.  vrcMainPtHpFreqAlarm    TruthValue,
  1978.  vrcMainPtLpSensorFailAlarm    TruthValue,
  1979.  vrcMainPtHpSensorFailAlarm    TruthValue,
  1980.  vrcMainPtEevCommFailAlarm    TruthValue
  1981. }
  1982.  
  1983. vrcMainPtIndex OBJECT-TYPE
  1984.  SYNTAX Integer32(1..100)
  1985.  MAX-ACCESS not-accessible
  1986.  STATUS current
  1987.  DESCRIPTION
  1988.   "Unique id for each entry in the table"
  1989.  ::= { vrcMainPtEntry 1 }
  1990.  
  1991. vrcMainPtRunState OBJECT-TYPE
  1992.  SYNTAX INTEGER {
  1993.    on(1),
  1994.    off(2)
  1995.    }
  1996.  MAX-ACCESS read-only
  1997.  STATUS current
  1998.  DESCRIPTION
  1999.   "VRC run state:
  2000.   1 = on
  2001.   2 = off"
  2002.  ::= { vrcMainPtEntry 2 }
  2003.  
  2004. vrcMainPtEevOpened OBJECT-TYPE
  2005.  SYNTAX Integer32(0..100)
  2006.  UNITS "%"
  2007.  MAX-ACCESS read-only
  2008.  STATUS current
  2009.  DESCRIPTION
  2010.   "Eev opened value (percent)"
  2011.  ::= { vrcMainPtEntry 3 }
  2012.  
  2013. vrcMainPtAlarmNumbers OBJECT-TYPE
  2014.  SYNTAX Integer32(-32768..32767)
  2015.  MAX-ACCESS read-only
  2016.  STATUS current
  2017.  DESCRIPTION
  2018.   "Alarm numbers value"
  2019.  ::= { vrcMainPtEntry 4 }
  2020.  
  2021. vrcMainPtHistoryAlarmNumbers OBJECT-TYPE
  2022.  SYNTAX Integer32(-32768..32767)
  2023.  MAX-ACCESS read-only
  2024.  STATUS current
  2025.  DESCRIPTION
  2026.   "History alarm numbers value"
  2027.  ::= { vrcMainPtEntry 5 }
  2028.  
  2029. vrcMainPtHpAbnRecordCnt OBJECT-TYPE
  2030.  SYNTAX Integer32(-32768..32767)
  2031.  MAX-ACCESS read-only
  2032.  STATUS current
  2033.  DESCRIPTION
  2034.   "Hp Abnormal record count"
  2035.  ::= { vrcMainPtEntry 6 }
  2036.  
  2037. vrcMainPtMonitorBaudrate OBJECT-TYPE
  2038.  SYNTAX INTEGER {
  2039.    error(1),
  2040.    baud1200(2),
  2041.    baud2400(3),
  2042.    baud4800(4),
  2043.    baud9600(5),
  2044.    baud19200(6)
  2045.    }
  2046.  MAX-ACCESS read-only
  2047.  STATUS current
  2048.  DESCRIPTION
  2049.   "Monitor baud rate:
  2050.   1 = error
  2051.   2 = 1200
  2052.   3 = 2400
  2053.   4 = 4800
  2054.   5 = 9600
  2055.   6 = 19200"
  2056.  ::= { vrcMainPtEntry 7 }
  2057.  
  2058. vrcMainPtMonitorAddress OBJECT-TYPE
  2059.  SYNTAX Integer32(1..247)
  2060.  MAX-ACCESS read-only
  2061.  STATUS current
  2062.  DESCRIPTION
  2063.   "Monitor address"
  2064.  ::= { vrcMainPtEntry 8 }
  2065.  
  2066. vrcMainPtLp OBJECT-TYPE
  2067.  SYNTAX TruthValue
  2068.  MAX-ACCESS read-only
  2069.  STATUS current
  2070.  DESCRIPTION
  2071.   "Lp status"
  2072.  ::= { vrcMainPtEntry 9 }
  2073.  
  2074. vrcMainPtFilterMaintRemind OBJECT-TYPE
  2075.  SYNTAX TruthValue
  2076.  MAX-ACCESS read-only
  2077.  STATUS current
  2078.  DESCRIPTION
  2079.   "Filter maintenance reminder status"
  2080.  ::= { vrcMainPtEntry 10 }
  2081.  
  2082. vrcMainPtCoolingFlag OBJECT-TYPE
  2083.  SYNTAX TruthValue
  2084.  MAX-ACCESS read-only
  2085.  STATUS current
  2086.  DESCRIPTION
  2087.   "Cooling flag"
  2088.  ::= { vrcMainPtEntry 11 }
  2089.  
  2090. vrcMainPtFirstOnFlag OBJECT-TYPE
  2091.  SYNTAX TruthValue
  2092.  MAX-ACCESS read-only
  2093.  STATUS current
  2094.  DESCRIPTION
  2095.   "First on flag"
  2096.  ::= { vrcMainPtEntry 12 }
  2097.  
  2098. vrcMainPtNewAlarmFlag OBJECT-TYPE
  2099.  SYNTAX TruthValue
  2100.  MAX-ACCESS read-only
  2101.  STATUS current
  2102.  DESCRIPTION
  2103.   "New alarm flag"
  2104.  ::= { vrcMainPtEntry 13 }
  2105.  
  2106. vrcMainPtComAlarmOutState OBJECT-TYPE
  2107.  SYNTAX TruthValue
  2108.  MAX-ACCESS read-only
  2109.  STATUS current
  2110.  DESCRIPTION
  2111.   "Common alarm output state"
  2112.  ::= { vrcMainPtEntry 14 }
  2113.  
  2114. vrcMainPtHighWaterInput OBJECT-TYPE
  2115.  SYNTAX TruthValue
  2116.  MAX-ACCESS read-only
  2117.  STATUS current
  2118.  DESCRIPTION
  2119.   "High water input"
  2120.  ::= { vrcMainPtEntry 15 }
  2121.  
  2122. vrcMainPtHighWaterAlarm OBJECT-TYPE
  2123.  SYNTAX TruthValue
  2124.  MAX-ACCESS read-only
  2125.  STATUS current
  2126.  DESCRIPTION
  2127.   "High water alarm status"
  2128.  ::= { vrcMainPtEntry 16 }
  2129.  
  2130. vrcMainPtWaterUnderFloorAlarm OBJECT-TYPE
  2131.  SYNTAX TruthValue
  2132.  MAX-ACCESS read-only
  2133.  STATUS current
  2134.  DESCRIPTION
  2135.   "Water under floor alarm status"
  2136.  ::= { vrcMainPtEntry 17 }
  2137.  
  2138. vrcMainPtSwShutDownStatus OBJECT-TYPE
  2139.  SYNTAX TruthValue
  2140.  MAX-ACCESS read-only
  2141.  STATUS current
  2142.  DESCRIPTION
  2143.   "Software shutdown status"
  2144.  ::= { vrcMainPtEntry 18 }
  2145.  
  2146. vrcMainPtRemoteShutdown OBJECT-TYPE
  2147.  SYNTAX TruthValue
  2148.  MAX-ACCESS read-only
  2149.  STATUS current
  2150.  DESCRIPTION
  2151.   "Remote shutdown status"
  2152.  ::= { vrcMainPtEntry 19 }
  2153.  
  2154. vrcMainPtRemoteShutDownFlag OBJECT-TYPE
  2155.  SYNTAX TruthValue
  2156.  MAX-ACCESS read-only
  2157.  STATUS current
  2158.  DESCRIPTION
  2159.   "Remote shutdown flag"
  2160.  ::= { vrcMainPtEntry 20 }
  2161.  
  2162. vrcMainPtRemoteShutDownAlarm OBJECT-TYPE
  2163.  SYNTAX TruthValue
  2164.  MAX-ACCESS read-only
  2165.  STATUS current
  2166.  DESCRIPTION
  2167.   "Remote shutdown alarm status"
  2168.  ::= { vrcMainPtEntry 21 }
  2169.  
  2170. vrcMainPtHmiShutDownFlag OBJECT-TYPE
  2171.  SYNTAX TruthValue
  2172.  MAX-ACCESS read-only
  2173.  STATUS current
  2174.  DESCRIPTION
  2175.   "Hmi shutdown flag"
  2176.  ::= { vrcMainPtEntry 22 }
  2177.  
  2178. vrcMainPtLpAlarm OBJECT-TYPE
  2179.  SYNTAX TruthValue
  2180.  MAX-ACCESS read-only
  2181.  STATUS current
  2182.  DESCRIPTION
  2183.   "Low pressure alarm status"
  2184.  ::= { vrcMainPtEntry 23 }
  2185.  
  2186. vrcMainPtHpAlarm OBJECT-TYPE
  2187.  SYNTAX TruthValue
  2188.  MAX-ACCESS read-only
  2189.  STATUS current
  2190.  DESCRIPTION
  2191.   "High pressure alarm status"
  2192.  ::= { vrcMainPtEntry 24 }
  2193.  
  2194. vrcMainPtLpFreqAlarm OBJECT-TYPE
  2195.  SYNTAX TruthValue
  2196.  MAX-ACCESS read-only
  2197.  STATUS current
  2198.  DESCRIPTION
  2199.   "Low pressure frequently alarm status"
  2200.  ::= { vrcMainPtEntry 25 }
  2201.  
  2202. vrcMainPtHpFreqAlarm OBJECT-TYPE
  2203.  SYNTAX TruthValue
  2204.  MAX-ACCESS read-only
  2205.  STATUS current
  2206.  DESCRIPTION
  2207.   "High pressure frequently alarm status"
  2208.  ::= { vrcMainPtEntry 26 }
  2209.  
  2210. vrcMainPtLpSensorFailAlarm OBJECT-TYPE
  2211.  SYNTAX TruthValue
  2212.  MAX-ACCESS read-only
  2213.  STATUS current
  2214.  DESCRIPTION
  2215.   "Low pressure sensor failure alarm status"
  2216.  ::= { vrcMainPtEntry 27 }
  2217.  
  2218. vrcMainPtHpSensorFailAlarm OBJECT-TYPE
  2219.  SYNTAX TruthValue
  2220.  MAX-ACCESS read-only
  2221.  STATUS current
  2222.  DESCRIPTION
  2223.   "High pressure sensor failure alarm status"
  2224.  ::= { vrcMainPtEntry 28 }
  2225.  
  2226. vrcMainPtEevCommFailAlarm OBJECT-TYPE
  2227.  SYNTAX TruthValue
  2228.  MAX-ACCESS read-only
  2229.  STATUS current
  2230.  DESCRIPTION
  2231.   "Eev communication failure alarm status"
  2232.  ::= { vrcMainPtEntry 29 }
  2233.  
  2234. --###########################################################################################--
  2235. --vrcMainCfgTable--
  2236. --###########################################################################################--
  2237.  
  2238. vrcMainCfgTable OBJECT-TYPE
  2239.  SYNTAX SEQUENCE OF VrcMainCfgEntry
  2240.  MAX-ACCESS  not-accessible
  2241.  STATUS current
  2242.  DESCRIPTION
  2243.   "Table that contains general VRC configuration"
  2244.  ::= { vrc 3 }
  2245.  
  2246. vrcMainCfgEntry OBJECT-TYPE
  2247.  SYNTAX VrcMainCfgEntry
  2248.  MAX-ACCESS  not-accessible
  2249.  STATUS current
  2250.  DESCRIPTION
  2251.   "Entry in the vrcMainCfgTable: each entry contains general config
  2252.   fields for a VRC device"
  2253.  INDEX { vrcMainCfgIndex }
  2254.  ::= { vrcMainCfgTable 1 }
  2255.  
  2256. VrcMainCfgEntry ::= SEQUENCE {
  2257.  vrcMainCfgIndex    Integer32,
  2258.  vrcMainCfgModelSelect    INTEGER,
  2259.  vrcMainCfgSystemTimeYear    Integer32,
  2260.  vrcMainCfgSystemTimeMonth    Integer32,
  2261.  vrcMainCfgSystemTimeDay    Integer32,
  2262.  vrcMainCfgSystemTimeHour    Integer32,
  2263.  vrcMainCfgSystemTimeMin    Integer32,
  2264.  vrcMainCfgSystemTimeSec    Integer32,
  2265.  vrcMainCfgEevShtSettingMin    Integer32,
  2266.  vrcMainCfgEevShtSettingMax    Integer32,
  2267.  vrcMainCfgEevValveCloseSht    Integer32,
  2268.  vrcMainCfgEevMopPressSetting    Integer32,
  2269.  vrcMainCfgLpdt    Integer32,
  2270.  vrcMainCfgDeadBand    Integer32,
  2271.  vrcMainCfgOnOffSwitch    TruthValue,
  2272.  vrcMainCfgVacuumState    TruthValue,
  2273.  vrcMainCfgControlMode    INTEGER,
  2274.  vrcMainCfgManualRunEnable    TruthValue,
  2275.  vrcMainCfgRemShutdownInput    TruthValue,
  2276.  vrcMainCfgMonitorShutDownFlag    TruthValue,
  2277.  vrcMainCfgFirstOnPassword    Integer32,
  2278.  vrcMainCfgFilterMaintSetting    TruthValue,
  2279.  vrcMainCfgFilterMaintRemindTime    Integer32,
  2280.  vrcMainCfgFilterMaintRemindCtrl    INTEGER,
  2281.  vrcMainCfgCommonAlarmOutputDir    TruthValue,
  2282.  vrcMainCfgHpAbnAlarmSetting    Integer32,
  2283.  vrcMainCfgLpAlarmCtrl    INTEGER,
  2284.  vrcMainCfgHpAlarmCtrl    INTEGER,
  2285.  vrcMainCfgLpFreqAlarmCtrl    INTEGER,
  2286.  vrcMainCfgHpFreqAlarmCtrl    INTEGER,
  2287.  vrcMainCfgLpSensorFailAlarmCtrl    INTEGER,
  2288.  vrcMainCfgHpSensorFailAlarmCtrl    INTEGER,
  2289.  vrcMainCfgHighWaterAlarmCtrl    INTEGER,
  2290.  vrcMainCfgRemShutdownAlarmCtrl    INTEGER,
  2291.  vrcMainCfgEevCommFailAlarmCtrl    INTEGER
  2292. }
  2293.  
  2294. vrcMainCfgIndex OBJECT-TYPE
  2295.  SYNTAX Integer32(1..100)
  2296.  MAX-ACCESS not-accessible
  2297.  STATUS current
  2298.  DESCRIPTION
  2299.   "Unique id for each entry in the table"
  2300.  ::= { vrcMainCfgEntry 1 }
  2301.  
  2302. vrcMainCfgModelSelect OBJECT-TYPE
  2303.  SYNTAX INTEGER {
  2304.    tmLoc(1),
  2305.    r035Ap(2),
  2306.    r035Ak(3),
  2307.    scLoc(4),
  2308.    zeroULoc(5),
  2309.    r035Ep(6),
  2310.    r035Ek(7)
  2311.    }
  2312.  MAX-ACCESS read-write
  2313.  STATUS current
  2314.  DESCRIPTION
  2315.   "Model Selection:
  2316.   1 = TMM-Local 220V 50/60HZ
  2317.   2 = TMM-Global 208/230V 50/60HZ
  2318.   3 = TMM-Global 120V 50/60HZ
  2319.   4 = SC 220V 50/60HZ
  2320.   5 = 0U 220V 50/60HZ
  2321.   6 = SS 208/230V 50/60HZ
  2322.   7 = SS 120V 50/60HZ"
  2323.  ::= { vrcMainCfgEntry 2 }
  2324.  
  2325. vrcMainCfgSystemTimeYear OBJECT-TYPE
  2326.  SYNTAX Integer32(2000..2099)
  2327.  MAX-ACCESS read-write
  2328.  STATUS current
  2329.  DESCRIPTION
  2330.   "System time - year"
  2331.  ::= { vrcMainCfgEntry 3 }
  2332.  
  2333. vrcMainCfgSystemTimeMonth OBJECT-TYPE
  2334.  SYNTAX Integer32(1..12)
  2335.  MAX-ACCESS read-write
  2336.  STATUS current
  2337.  DESCRIPTION
  2338.   "System time - month"
  2339.  ::= { vrcMainCfgEntry 4 }
  2340.  
  2341. vrcMainCfgSystemTimeDay OBJECT-TYPE
  2342.  SYNTAX Integer32(1..31)
  2343.  MAX-ACCESS read-write
  2344.  STATUS current
  2345.  DESCRIPTION
  2346.   "System time - day"
  2347.  ::= { vrcMainCfgEntry 5 }
  2348.  
  2349. vrcMainCfgSystemTimeHour OBJECT-TYPE
  2350.  SYNTAX Integer32(0..23)
  2351.  MAX-ACCESS read-write
  2352.  STATUS current
  2353.  DESCRIPTION
  2354.   "System time - hour"
  2355.  ::= { vrcMainCfgEntry 6 }
  2356.  
  2357. vrcMainCfgSystemTimeMin OBJECT-TYPE
  2358.  SYNTAX Integer32(0..59)
  2359.  MAX-ACCESS read-write
  2360.  STATUS current
  2361.  DESCRIPTION
  2362.   "System time - minutes"
  2363.  ::= { vrcMainCfgEntry 7 }
  2364.  
  2365. vrcMainCfgSystemTimeSec OBJECT-TYPE
  2366.  SYNTAX Integer32(0..59)
  2367.  MAX-ACCESS read-write
  2368.  STATUS current
  2369.  DESCRIPTION
  2370.   "System time - seconds"
  2371.  ::= { vrcMainCfgEntry 8 }
  2372.  
  2373. vrcMainCfgEevShtSettingMin OBJECT-TYPE
  2374.  SYNTAX Integer32
  2375.  UNITS "decidegrees"
  2376.  MAX-ACCESS read-write
  2377.  STATUS current
  2378.  DESCRIPTION
  2379.   "Min Eev sht in tenths of a degree. Units are given by temperatureUnits
  2380.   field in deviceInfo. The settable range is determined by the current
  2381.   temperature units.
  2382.   Celsius:    50 to 200
  2383.   Fahrenheit: 90 to 359"
  2384.  ::= { vrcMainCfgEntry 9 }
  2385.  
  2386. vrcMainCfgEevShtSettingMax OBJECT-TYPE
  2387.  SYNTAX Integer32
  2388.  UNITS "decidegrees"
  2389.  MAX-ACCESS read-write
  2390.  STATUS current
  2391.  DESCRIPTION
  2392.   "Max Eev sht in tenths of a degree. Units are given by temperatureUnits
  2393.   field in deviceInfo. The settable range is determined by the current
  2394.   temperature units.
  2395.   Celsius:    50 to 200
  2396.   Fahrenheit: 90 to 359"
  2397.  ::= { vrcMainCfgEntry 10 }
  2398.  
  2399. vrcMainCfgEevValveCloseSht OBJECT-TYPE
  2400.  SYNTAX Integer32
  2401.  UNITS "decidegrees"
  2402.  MAX-ACCESS read-write
  2403.  STATUS current
  2404.  DESCRIPTION
  2405.   "Eev valve close sht in tenths of a degree. Units are given by
  2406.   temperatureUnits field in deviceInfo. The settable range is determined
  2407.   by the current temperature units.
  2408.   Celsius:    0 to 100
  2409.   Fahrenheit: 0 to 179"
  2410.  ::= { vrcMainCfgEntry 11 }
  2411.  
  2412. vrcMainCfgEevMopPressSetting OBJECT-TYPE
  2413.  SYNTAX Integer32(0..200)
  2414.  UNITS "decibars"
  2415.  MAX-ACCESS read-write
  2416.  STATUS current
  2417.  DESCRIPTION
  2418.   "Eev mop pressure setting in tenths of a bar."
  2419.  ::= { vrcMainCfgEntry 12 }
  2420.  
  2421. vrcMainCfgLpdt OBJECT-TYPE
  2422.  SYNTAX Integer32(30..600)
  2423.  UNITS "seconds"
  2424.  MAX-ACCESS read-write
  2425.  STATUS current
  2426.  DESCRIPTION
  2427.   "Low pressure dt in seconds"
  2428.  ::= { vrcMainCfgEntry 13 }
  2429.  
  2430. vrcMainCfgDeadBand OBJECT-TYPE
  2431.  SYNTAX Integer32
  2432.  UNITS "decidegrees"
  2433.  MAX-ACCESS read-write
  2434.  STATUS current
  2435.  DESCRIPTION
  2436.   "Dead band in tenths of a degree. Units are given by temperatureUnits
  2437.   field in deviceInfo. The settable range is determined by the current
  2438.   temperature units.
  2439.   Celsius:    0 to 20
  2440.   Fahrenheit: 0 to 35"
  2441.  ::= { vrcMainCfgEntry 14 }
  2442.  
  2443. vrcMainCfgOnOffSwitch OBJECT-TYPE
  2444.  SYNTAX TruthValue
  2445.  MAX-ACCESS read-write
  2446.  STATUS current
  2447.  DESCRIPTION
  2448.   "On-off switch"
  2449.  ::= { vrcMainCfgEntry 15 }
  2450.  
  2451. vrcMainCfgVacuumState OBJECT-TYPE
  2452.  SYNTAX TruthValue
  2453.  MAX-ACCESS read-write
  2454.  STATUS current
  2455.  DESCRIPTION
  2456.   "Vacuum state"
  2457.  ::= { vrcMainCfgEntry 16 }
  2458.  
  2459. vrcMainCfgControlMode OBJECT-TYPE
  2460.  SYNTAX INTEGER {
  2461.    supply(1),
  2462.    return(2)
  2463.    }
  2464.  MAX-ACCESS read-write
  2465.  STATUS current
  2466.  DESCRIPTION
  2467.   "Control mode:
  2468.   1 = supply
  2469.   2 = return"
  2470.  ::= { vrcMainCfgEntry 17 }
  2471.  
  2472. vrcMainCfgManualRunEnable OBJECT-TYPE
  2473.  SYNTAX TruthValue
  2474.  MAX-ACCESS read-write
  2475.  STATUS current
  2476.  DESCRIPTION
  2477.   "Manual run enable"
  2478.  ::= { vrcMainCfgEntry 18 }
  2479.  
  2480. vrcMainCfgRemShutdownInput OBJECT-TYPE
  2481.  SYNTAX TruthValue
  2482.  MAX-ACCESS read-write
  2483.  STATUS current
  2484.  DESCRIPTION
  2485.   "Remote shutdown input"
  2486.  ::= { vrcMainCfgEntry 19 }
  2487.  
  2488. vrcMainCfgMonitorShutDownFlag OBJECT-TYPE
  2489.  SYNTAX TruthValue
  2490.  MAX-ACCESS read-write
  2491.  STATUS current
  2492.  DESCRIPTION
  2493.   "Monitor shutdown flag"
  2494.  ::= { vrcMainCfgEntry 20 }
  2495.  
  2496. vrcMainCfgFirstOnPassword OBJECT-TYPE
  2497.  SYNTAX Integer32(-32768..32767)
  2498.  MAX-ACCESS read-write
  2499.  STATUS current
  2500.  DESCRIPTION
  2501.   "First on password value"
  2502.  ::= { vrcMainCfgEntry 21 }
  2503.  
  2504. vrcMainCfgFilterMaintSetting OBJECT-TYPE
  2505.  SYNTAX TruthValue
  2506.  MAX-ACCESS read-write
  2507.  STATUS current
  2508.  DESCRIPTION
  2509.   "Filter maintenance setting"
  2510.  ::= { vrcMainCfgEntry 22 }
  2511.  
  2512. vrcMainCfgFilterMaintRemindTime OBJECT-TYPE
  2513.  SYNTAX Integer32(30..360)
  2514.  UNITS "days"
  2515.  MAX-ACCESS read-write
  2516.  STATUS current
  2517.  DESCRIPTION
  2518.   "Time between filter maintenance reminders in days"
  2519.  ::= { vrcMainCfgEntry 23 }
  2520.  
  2521. vrcMainCfgFilterMaintRemindCtrl OBJECT-TYPE
  2522.  SYNTAX INTEGER {
  2523.    close(1),
  2524.    suspend(2),
  2525.    open(3)
  2526.    }
  2527.  MAX-ACCESS read-write
  2528.  STATUS current
  2529.  DESCRIPTION
  2530.   "Filter maintenance reminder:
  2531.   1 = close
  2532.   2 = suspend
  2533.   3 = open"
  2534.  ::= { vrcMainCfgEntry 24 }
  2535.  
  2536. vrcMainCfgCommonAlarmOutputDir OBJECT-TYPE
  2537.  SYNTAX TruthValue
  2538.  MAX-ACCESS read-write
  2539.  STATUS current
  2540.  DESCRIPTION
  2541.   "Common alarm output direction"
  2542.  ::= { vrcMainCfgEntry 25 }
  2543.  
  2544. vrcMainCfgHpAbnAlarmSetting OBJECT-TYPE
  2545.  SYNTAX Integer32(300..360)
  2546.  UNITS "decibars"
  2547.  MAX-ACCESS read-write
  2548.  STATUS current
  2549.  DESCRIPTION
  2550.   "Abnormal high pressure alarm value in tenths of a bar"
  2551.  ::= { vrcMainCfgEntry 26 }
  2552.  
  2553. vrcMainCfgLpAlarmCtrl OBJECT-TYPE
  2554.  SYNTAX INTEGER {
  2555.    suspend(2),
  2556.    open(3)
  2557.    }
  2558.  MAX-ACCESS read-write
  2559.  STATUS current
  2560.  DESCRIPTION
  2561.   "Low pressure alarm control:
  2562.   2 = suspend
  2563.   3 = open"
  2564.  ::= { vrcMainCfgEntry 27 }
  2565.  
  2566. vrcMainCfgHpAlarmCtrl OBJECT-TYPE
  2567.  SYNTAX INTEGER {
  2568.    suspend(2),
  2569.    open(3)
  2570.    }
  2571.  MAX-ACCESS read-write
  2572.  STATUS current
  2573.  DESCRIPTION
  2574.   "High pressure alarm control:
  2575.   2 = suspend
  2576.   3 = open"
  2577.  ::= { vrcMainCfgEntry 28 }
  2578.  
  2579. vrcMainCfgLpFreqAlarmCtrl OBJECT-TYPE
  2580.  SYNTAX INTEGER {
  2581.    suspend(2),
  2582.    open(3)
  2583.    }
  2584.  MAX-ACCESS read-write
  2585.  STATUS current
  2586.  DESCRIPTION
  2587.   "Low pressure frequently alarm control:
  2588.   2 = suspend
  2589.   3 = open"
  2590.  ::= { vrcMainCfgEntry 29 }
  2591.  
  2592. vrcMainCfgHpFreqAlarmCtrl OBJECT-TYPE
  2593.  SYNTAX INTEGER {
  2594.    suspend(2),
  2595.    open(3)
  2596.    }
  2597.  MAX-ACCESS read-write
  2598.  STATUS current
  2599.  DESCRIPTION
  2600.   "High pressure frequently alarm control:
  2601.   2 = suspend
  2602.   3 = open"
  2603.  ::= { vrcMainCfgEntry 30 }
  2604.  
  2605. vrcMainCfgLpSensorFailAlarmCtrl OBJECT-TYPE
  2606.  SYNTAX INTEGER {
  2607.    suspend(2),
  2608.    open(3)
  2609.    }
  2610.  MAX-ACCESS read-write
  2611.  STATUS current
  2612.  DESCRIPTION
  2613.   "Low pressure sensor failure alarm control:
  2614.   2 = suspend
  2615.   3 = open"
  2616.  ::= { vrcMainCfgEntry 31 }
  2617.  
  2618. vrcMainCfgHpSensorFailAlarmCtrl OBJECT-TYPE
  2619.  SYNTAX INTEGER {
  2620.    suspend(2),
  2621.    open(3)
  2622.    }
  2623.  MAX-ACCESS read-write
  2624.  STATUS current
  2625.  DESCRIPTION
  2626.   "High pressure sensor failure alarm control:
  2627.   2 = suspend
  2628.   3 = open"
  2629.  ::= { vrcMainCfgEntry 32 }
  2630.  
  2631. vrcMainCfgHighWaterAlarmCtrl OBJECT-TYPE
  2632.  SYNTAX INTEGER {
  2633.    close(1),
  2634.    suspend(2),
  2635.    open(3)
  2636.    }
  2637.  MAX-ACCESS read-write
  2638.  STATUS current
  2639.  DESCRIPTION
  2640.   "High water alarm control:
  2641.   1 = close
  2642.   2 = suspend
  2643.   3 = open"
  2644.  ::= { vrcMainCfgEntry 33 }
  2645.  
  2646. vrcMainCfgRemShutdownAlarmCtrl OBJECT-TYPE
  2647.  SYNTAX INTEGER {
  2648.    suspend(2),
  2649.    open(3)
  2650.    }
  2651.  MAX-ACCESS read-write
  2652.  STATUS current
  2653.  DESCRIPTION
  2654.   "Remote shutdown alarm control:
  2655.   2 = suspend
  2656.   3 = open"
  2657.  ::= { vrcMainCfgEntry 34 }
  2658.  
  2659. vrcMainCfgEevCommFailAlarmCtrl OBJECT-TYPE
  2660.  SYNTAX INTEGER {
  2661.    suspend(2),
  2662.    open(3)
  2663.    }
  2664.  MAX-ACCESS read-write
  2665.  STATUS current
  2666.  DESCRIPTION
  2667.   "Eev communication failure alarm:
  2668.   2 = suspend
  2669.   3 = open"
  2670.  ::= { vrcMainCfgEntry 35 }
  2671.  
  2672. --###########################################################################################--
  2673. --vrcOutFanPtTable--
  2674. --###########################################################################################--
  2675.  
  2676. vrcOutFanPtTable OBJECT-TYPE
  2677.  SYNTAX SEQUENCE OF VrcOutFanPtEntry
  2678.  MAX-ACCESS  not-accessible
  2679.  STATUS current
  2680.  DESCRIPTION
  2681.   "Table that contains VRC out-fan status"
  2682.  ::= { vrc 4 }
  2683.  
  2684. vrcOutFanPtEntry OBJECT-TYPE
  2685.  SYNTAX VrcOutFanPtEntry
  2686.  MAX-ACCESS  not-accessible
  2687.  STATUS current
  2688.  DESCRIPTION
  2689.   "Entry in the vrcOutFanPtTable: each entry represents data for a VRC
  2690.   out-fan"
  2691.  INDEX { vrcOutFanPtIndex }
  2692.  ::= { vrcOutFanPtTable 1 }
  2693.  
  2694. VrcOutFanPtEntry ::= SEQUENCE {
  2695.  vrcOutFanPtIndex    Integer32,
  2696.  vrcOutFanPtName    SnmpAdminString,
  2697.  vrcOutFanPtSpeed    Integer32
  2698. }
  2699.  
  2700. vrcOutFanPtIndex OBJECT-TYPE
  2701.  SYNTAX Integer32(1..100)
  2702.  MAX-ACCESS not-accessible
  2703.  STATUS current
  2704.  DESCRIPTION
  2705.   "Unique id for each entry in the table"
  2706.  ::= { vrcOutFanPtEntry 1 }
  2707.  
  2708. vrcOutFanPtName OBJECT-TYPE
  2709.  SYNTAX SnmpAdminString(SIZE (1..25))
  2710.  MAX-ACCESS read-only
  2711.  STATUS current
  2712.  DESCRIPTION
  2713.   "Out-fan name (factory-assigned)"
  2714.  ::= { vrcOutFanPtEntry 2 }
  2715.  
  2716. vrcOutFanPtSpeed OBJECT-TYPE
  2717.  SYNTAX Integer32(0..100)
  2718.  UNITS "%"
  2719.  MAX-ACCESS read-only
  2720.  STATUS current
  2721.  DESCRIPTION
  2722.   "Fan speed (percent)"
  2723.  ::= { vrcOutFanPtEntry 3 }
  2724.  
  2725. --###########################################################################################--
  2726. --vrcOutFanCfgTable--
  2727. --###########################################################################################--
  2728.  
  2729. vrcOutFanCfgTable OBJECT-TYPE
  2730.  SYNTAX SEQUENCE OF VrcOutFanCfgEntry
  2731.  MAX-ACCESS  not-accessible
  2732.  STATUS current
  2733.  DESCRIPTION
  2734.   "Table used for VRC out-fan configuration"
  2735.  ::= { vrc 5 }
  2736.  
  2737. vrcOutFanCfgEntry OBJECT-TYPE
  2738.  SYNTAX VrcOutFanCfgEntry
  2739.  MAX-ACCESS  not-accessible
  2740.  STATUS current
  2741.  DESCRIPTION
  2742.   "Entry in the vrcOutFanCfgTable: each entry contains config fields for
  2743.   a VRC out-fan"
  2744.  INDEX { vrcOutFanCfgIndex }
  2745.  ::= { vrcOutFanCfgTable 1 }
  2746.  
  2747. VrcOutFanCfgEntry ::= SEQUENCE {
  2748.  vrcOutFanCfgIndex    Integer32,
  2749.  vrcOutFanCfgStartPress    Integer32,
  2750.  vrcOutFanCfgPressSetting    Integer32,
  2751.  vrcOutFanCfgMinPowerVoltage    Integer32,
  2752.  vrcOutFanCfgMaxPowerVoltage    Integer32,
  2753.  vrcOutFanCfgSpeed    Integer32
  2754. }
  2755.  
  2756. vrcOutFanCfgIndex OBJECT-TYPE
  2757.  SYNTAX Integer32(1..100)
  2758.  MAX-ACCESS not-accessible
  2759.  STATUS current
  2760.  DESCRIPTION
  2761.   "Unique id for each entry in the table"
  2762.  ::= { vrcOutFanCfgEntry 1 }
  2763.  
  2764. vrcOutFanCfgStartPress OBJECT-TYPE
  2765.  SYNTAX Integer32(190..250)
  2766.  UNITS "decibars"
  2767.  MAX-ACCESS read-write
  2768.  STATUS current
  2769.  DESCRIPTION
  2770.   "Out-fan start pressure in tenths of a bar"
  2771.  ::= { vrcOutFanCfgEntry 2 }
  2772.  
  2773. vrcOutFanCfgPressSetting OBJECT-TYPE
  2774.  SYNTAX Integer32(50..80)
  2775.  UNITS "decibars"
  2776.  MAX-ACCESS read-write
  2777.  STATUS current
  2778.  DESCRIPTION
  2779.   "Out-fan pressure setting in tenths of a bar"
  2780.  ::= { vrcOutFanCfgEntry 3 }
  2781.  
  2782. vrcOutFanCfgMinPowerVoltage OBJECT-TYPE
  2783.  SYNTAX Integer32(30..50)
  2784.  UNITS "%"
  2785.  MAX-ACCESS read-write
  2786.  STATUS current
  2787.  DESCRIPTION
  2788.   "Min out-fan voltage (percent)"
  2789.  ::= { vrcOutFanCfgEntry 4 }
  2790.  
  2791. vrcOutFanCfgMaxPowerVoltage OBJECT-TYPE
  2792.  SYNTAX Integer32(60..100)
  2793.  UNITS "%"
  2794.  MAX-ACCESS read-write
  2795.  STATUS current
  2796.  DESCRIPTION
  2797.   "Max out-fan voltage (percent)"
  2798.  ::= { vrcOutFanCfgEntry 5 }
  2799.  
  2800. vrcOutFanCfgSpeed OBJECT-TYPE
  2801.  SYNTAX Integer32(0..100)
  2802.  UNITS "%"
  2803.  MAX-ACCESS read-write
  2804.  STATUS current
  2805.  DESCRIPTION
  2806.   "Out-fan speed  (percent)"
  2807.  ::= { vrcOutFanCfgEntry 6 }
  2808.  
  2809. --###########################################################################################--
  2810. --vrcInFanPtTable--
  2811. --###########################################################################################--
  2812.  
  2813. vrcInFanPtTable OBJECT-TYPE
  2814.  SYNTAX SEQUENCE OF VrcInFanPtEntry
  2815.  MAX-ACCESS  not-accessible
  2816.  STATUS current
  2817.  DESCRIPTION
  2818.   "Table that contains VRC in-fan status"
  2819.  ::= { vrc 6 }
  2820.  
  2821. vrcInFanPtEntry OBJECT-TYPE
  2822.  SYNTAX VrcInFanPtEntry
  2823.  MAX-ACCESS  not-accessible
  2824.  STATUS current
  2825.  DESCRIPTION
  2826.   "Entry in the vrcInFanPtTable: each entry represents data for a VRC in-
  2827.   fan"
  2828.  INDEX { vrcInFanPtIndex }
  2829.  ::= { vrcInFanPtTable 1 }
  2830.  
  2831. VrcInFanPtEntry ::= SEQUENCE {
  2832.  vrcInFanPtIndex    Integer32,
  2833.  vrcInFanPtName    SnmpAdminString,
  2834.  vrcInFanPtRunTimeHours    Integer32,
  2835.  vrcInFanPtStartStopCount    Integer32
  2836. }
  2837.  
  2838. vrcInFanPtIndex OBJECT-TYPE
  2839.  SYNTAX Integer32(1..100)
  2840.  MAX-ACCESS not-accessible
  2841.  STATUS current
  2842.  DESCRIPTION
  2843.   "Unique id for each entry in the table"
  2844.  ::= { vrcInFanPtEntry 1 }
  2845.  
  2846. vrcInFanPtName OBJECT-TYPE
  2847.  SYNTAX SnmpAdminString(SIZE (1..25))
  2848.  MAX-ACCESS read-only
  2849.  STATUS current
  2850.  DESCRIPTION
  2851.   "In-fan name (factory-assigned)"
  2852.  ::= { vrcInFanPtEntry 2 }
  2853.  
  2854. vrcInFanPtRunTimeHours OBJECT-TYPE
  2855.  SYNTAX Integer32(-32768..32767)
  2856.  UNITS "hours"
  2857.  MAX-ACCESS read-only
  2858.  STATUS current
  2859.  DESCRIPTION
  2860.   "In-fan run time in hours"
  2861.  ::= { vrcInFanPtEntry 3 }
  2862.  
  2863. vrcInFanPtStartStopCount OBJECT-TYPE
  2864.  SYNTAX Integer32(-32768..32767)
  2865.  MAX-ACCESS read-only
  2866.  STATUS current
  2867.  DESCRIPTION
  2868.   "In-fan start/stop count"
  2869.  ::= { vrcInFanPtEntry 4 }
  2870.  
  2871. --###########################################################################################--
  2872. --vrcInFanCfgTable--
  2873. --###########################################################################################--
  2874.  
  2875. vrcInFanCfgTable OBJECT-TYPE
  2876.  SYNTAX SEQUENCE OF VrcInFanCfgEntry
  2877.  MAX-ACCESS  not-accessible
  2878.  STATUS current
  2879.  DESCRIPTION
  2880.   "Table used for VRC in-fan configuration"
  2881.  ::= { vrc 7 }
  2882.  
  2883. vrcInFanCfgEntry OBJECT-TYPE
  2884.  SYNTAX VrcInFanCfgEntry
  2885.  MAX-ACCESS  not-accessible
  2886.  STATUS current
  2887.  DESCRIPTION
  2888.   "Entry in the vrcInFanCfgTable: each entry contains config fields for a
  2889.   VRC in-fan"
  2890.  INDEX { vrcInFanCfgIndex }
  2891.  ::= { vrcInFanCfgTable 1 }
  2892.  
  2893. VrcInFanCfgEntry ::= SEQUENCE {
  2894.  vrcInFanCfgIndex    Integer32,
  2895.  vrcInFanCfgOutputStatus    TruthValue,
  2896.  vrcInFanCfgLowSpeedStep    Integer32,
  2897.  vrcInFanCfgHighSpeedStep    Integer32,
  2898.  vrcInFanCfgMinSpeed    Integer32,
  2899.  vrcInFanCfgStandardSpeed    Integer32,
  2900.  vrcInFanCfgMinCfc    Integer32,
  2901.  vrcInFanCfgStandardCfc    Integer32,
  2902.  vrcInFanCfgStartDelay    Integer32,
  2903.  vrcInFanCfgStopDelay    Integer32,
  2904.  vrcInFanCfgReduceSpeedDelay    Integer32,
  2905.  vrcInFanCfgJumpBand1    Integer32,
  2906.  vrcInFanCfgJumpBand2    Integer32,
  2907.  vrcInFanCfgJumpBand3    Integer32,
  2908.  vrcInFanCfgJumpBand4    Integer32,
  2909.  vrcInFanCfgJumpBand5    Integer32,
  2910.  vrcInFanCfgJumpFreq1    Integer32,
  2911.  vrcInFanCfgJumpFreq2    Integer32,
  2912.  vrcInFanCfgJumpFreq3    Integer32,
  2913.  vrcInFanCfgJumpFreq4    Integer32,
  2914.  vrcInFanCfgJumpFreq5    Integer32,
  2915.  vrcInFanCfgTempP    Integer32,
  2916.  vrcInFanCfgTempI    Integer32,
  2917.  vrcInFanCfgTempD    Integer32
  2918. }
  2919.  
  2920. vrcInFanCfgIndex OBJECT-TYPE
  2921.  SYNTAX Integer32(1..100)
  2922.  MAX-ACCESS not-accessible
  2923.  STATUS current
  2924.  DESCRIPTION
  2925.   "Unique id for each entry in the table"
  2926.  ::= { vrcInFanCfgEntry 1 }
  2927.  
  2928. vrcInFanCfgOutputStatus OBJECT-TYPE
  2929.  SYNTAX TruthValue
  2930.  MAX-ACCESS read-write
  2931.  STATUS current
  2932.  DESCRIPTION
  2933.   "In-fan output status"
  2934.  ::= { vrcInFanCfgEntry 2 }
  2935.  
  2936. vrcInFanCfgLowSpeedStep OBJECT-TYPE
  2937.  SYNTAX Integer32(1..20)
  2938.  UNITS "0.1%/s"
  2939.  MAX-ACCESS read-write
  2940.  STATUS current
  2941.  DESCRIPTION
  2942.   "In-fan low speed step in tenths of a percent per second"
  2943.  ::= { vrcInFanCfgEntry 3 }
  2944.  
  2945. vrcInFanCfgHighSpeedStep OBJECT-TYPE
  2946.  SYNTAX Integer32(1..50)
  2947.  UNITS "0.1%/s"
  2948.  MAX-ACCESS read-write
  2949.  STATUS current
  2950.  DESCRIPTION
  2951.   "In-fan high speed step in tenths of a percent per second"
  2952.  ::= { vrcInFanCfgEntry 4 }
  2953.  
  2954. vrcInFanCfgMinSpeed OBJECT-TYPE
  2955.  SYNTAX Integer32(30..80)
  2956.  UNITS "%"
  2957.  MAX-ACCESS read-write
  2958.  STATUS current
  2959.  DESCRIPTION
  2960.   "Min in-fan speed (percent)"
  2961.  ::= { vrcInFanCfgEntry 5 }
  2962.  
  2963. vrcInFanCfgStandardSpeed OBJECT-TYPE
  2964.  SYNTAX Integer32(80..100)
  2965.  UNITS "%"
  2966.  MAX-ACCESS read-write
  2967.  STATUS current
  2968.  DESCRIPTION
  2969.   "Standard in-fan speed (percent)"
  2970.  ::= { vrcInFanCfgEntry 6 }
  2971.  
  2972. vrcInFanCfgMinCfc OBJECT-TYPE
  2973.  SYNTAX Integer32(0..30)
  2974.  UNITS "%"
  2975.  MAX-ACCESS read-write
  2976.  STATUS current
  2977.  DESCRIPTION
  2978.   "Min in-fan cfc (percent)"
  2979.  ::= { vrcInFanCfgEntry 7 }
  2980.  
  2981. vrcInFanCfgStandardCfc OBJECT-TYPE
  2982.  SYNTAX Integer32(85..100)
  2983.  UNITS "%"
  2984.  MAX-ACCESS read-write
  2985.  STATUS current
  2986.  DESCRIPTION
  2987.   "Standard in-fan cfc (percent)"
  2988.  ::= { vrcInFanCfgEntry 8 }
  2989.  
  2990. vrcInFanCfgStartDelay OBJECT-TYPE
  2991.  SYNTAX Integer32(10..600)
  2992.  UNITS "seconds"
  2993.  MAX-ACCESS read-write
  2994.  STATUS current
  2995.  DESCRIPTION
  2996.   "In-fan start delay in seconds"
  2997.  ::= { vrcInFanCfgEntry 9 }
  2998.  
  2999. vrcInFanCfgStopDelay OBJECT-TYPE
  3000.  SYNTAX Integer32(10..300)
  3001.  UNITS "seconds"
  3002.  MAX-ACCESS read-write
  3003.  STATUS current
  3004.  DESCRIPTION
  3005.   "In-fan stop delay in seconds"
  3006.  ::= { vrcInFanCfgEntry 10 }
  3007.  
  3008. vrcInFanCfgReduceSpeedDelay OBJECT-TYPE
  3009.  SYNTAX Integer32(0..300)
  3010.  UNITS "seconds"
  3011.  MAX-ACCESS read-write
  3012.  STATUS current
  3013.  DESCRIPTION
  3014.   "In-fan reduce speed delay in seconds"
  3015.  ::= { vrcInFanCfgEntry 11 }
  3016.  
  3017. vrcInFanCfgJumpBand1 OBJECT-TYPE
  3018.  SYNTAX Integer32(0..100)
  3019.  UNITS "0.1%"
  3020.  MAX-ACCESS read-write
  3021.  STATUS current
  3022.  DESCRIPTION
  3023.   "In-fan jump band 1 in tenths of a percent"
  3024.  ::= { vrcInFanCfgEntry 12 }
  3025.  
  3026. vrcInFanCfgJumpBand2 OBJECT-TYPE
  3027.  SYNTAX Integer32(0..100)
  3028.  UNITS "0.1%"
  3029.  MAX-ACCESS read-write
  3030.  STATUS current
  3031.  DESCRIPTION
  3032.   "In-fan jump band 2 in tenths of a percent"
  3033.  ::= { vrcInFanCfgEntry 13 }
  3034.  
  3035. vrcInFanCfgJumpBand3 OBJECT-TYPE
  3036.  SYNTAX Integer32(0..100)
  3037.  UNITS "0.1%"
  3038.  MAX-ACCESS read-write
  3039.  STATUS current
  3040.  DESCRIPTION
  3041.   "In-fan jump band 3 in tenths of a percent"
  3042.  ::= { vrcInFanCfgEntry 14 }
  3043.  
  3044. vrcInFanCfgJumpBand4 OBJECT-TYPE
  3045.  SYNTAX Integer32(0..100)
  3046.  UNITS "0.1%"
  3047.  MAX-ACCESS read-write
  3048.  STATUS current
  3049.  DESCRIPTION
  3050.   "In-fan jump band 4 in tenths of a percent"
  3051.  ::= { vrcInFanCfgEntry 15 }
  3052.  
  3053. vrcInFanCfgJumpBand5 OBJECT-TYPE
  3054.  SYNTAX Integer32(0..100)
  3055.  UNITS "0.1%"
  3056.  MAX-ACCESS read-write
  3057.  STATUS current
  3058.  DESCRIPTION
  3059.   "In-fan jump band 5 in tenths of a percent"
  3060.  ::= { vrcInFanCfgEntry 16 }
  3061.  
  3062. vrcInFanCfgJumpFreq1 OBJECT-TYPE
  3063.  SYNTAX Integer32(0..1000)
  3064.  UNITS "0.1%"
  3065.  MAX-ACCESS read-write
  3066.  STATUS current
  3067.  DESCRIPTION
  3068.   "In-fan jump frequency 1 in tenths of a percent"
  3069.  ::= { vrcInFanCfgEntry 17 }
  3070.  
  3071. vrcInFanCfgJumpFreq2 OBJECT-TYPE
  3072.  SYNTAX Integer32(0..1000)
  3073.  UNITS "0.1%"
  3074.  MAX-ACCESS read-write
  3075.  STATUS current
  3076.  DESCRIPTION
  3077.   "In-fan jump frequency 2 in tenths of a percent"
  3078.  ::= { vrcInFanCfgEntry 18 }
  3079.  
  3080. vrcInFanCfgJumpFreq3 OBJECT-TYPE
  3081.  SYNTAX Integer32(0..1000)
  3082.  UNITS "0.1%"
  3083.  MAX-ACCESS read-write
  3084.  STATUS current
  3085.  DESCRIPTION
  3086.   "In-fan jump frequency 3 in tenths of a percent"
  3087.  ::= { vrcInFanCfgEntry 19 }
  3088.  
  3089. vrcInFanCfgJumpFreq4 OBJECT-TYPE
  3090.  SYNTAX Integer32(0..1000)
  3091.  UNITS "0.1%"
  3092.  MAX-ACCESS read-write
  3093.  STATUS current
  3094.  DESCRIPTION
  3095.   "In-fan jump frequency 4 in tenths of a percent"
  3096.  ::= { vrcInFanCfgEntry 20 }
  3097.  
  3098. vrcInFanCfgJumpFreq5 OBJECT-TYPE
  3099.  SYNTAX Integer32(0..1000)
  3100.  UNITS "0.1%"
  3101.  MAX-ACCESS read-write
  3102.  STATUS current
  3103.  DESCRIPTION
  3104.   "In-fan jump frequency 5 in tenths of a percent"
  3105.  ::= { vrcInFanCfgEntry 21 }
  3106.  
  3107. vrcInFanCfgTempP OBJECT-TYPE
  3108.  SYNTAX Integer32(10..150)
  3109.  UNITS "decidegrees"
  3110.  MAX-ACCESS read-write
  3111.  STATUS current
  3112.  DESCRIPTION
  3113.   "In-fan temperature P in tenths of a degree. Units are given by
  3114.   temperatureUnits field in deviceInfo."
  3115.  ::= { vrcInFanCfgEntry 22 }
  3116.  
  3117. vrcInFanCfgTempI OBJECT-TYPE
  3118.  SYNTAX Integer32(0..900)
  3119.  UNITS "seconds"
  3120.  MAX-ACCESS read-write
  3121.  STATUS current
  3122.  DESCRIPTION
  3123.   "In-fan temperature I in seconds"
  3124.  ::= { vrcInFanCfgEntry 23 }
  3125.  
  3126. vrcInFanCfgTempD OBJECT-TYPE
  3127.  SYNTAX Integer32(0..900)
  3128.  UNITS "seconds"
  3129.  MAX-ACCESS read-write
  3130.  STATUS current
  3131.  DESCRIPTION
  3132.   "In-fan temperature D in seconds"
  3133.  ::= { vrcInFanCfgEntry 24 }
  3134.  
  3135. --###########################################################################################--
  3136. --vrcCompPtTable--
  3137. --###########################################################################################--
  3138.  
  3139. vrcCompPtTable OBJECT-TYPE
  3140.  SYNTAX SEQUENCE OF VrcCompPtEntry
  3141.  MAX-ACCESS  not-accessible
  3142.  STATUS current
  3143.  DESCRIPTION
  3144.   "Table that contains VRC compressor status"
  3145.  ::= { vrc 8 }
  3146.  
  3147. vrcCompPtEntry OBJECT-TYPE
  3148.  SYNTAX VrcCompPtEntry
  3149.  MAX-ACCESS  not-accessible
  3150.  STATUS current
  3151.  DESCRIPTION
  3152.   "Entry in the vrcCompPtTable: each entry represents data for a VRC
  3153.   compressor"
  3154.  INDEX { vrcCompPtIndex }
  3155.  ::= { vrcCompPtTable 1 }
  3156.  
  3157. VrcCompPtEntry ::= SEQUENCE {
  3158.  vrcCompPtIndex    Integer32,
  3159.  vrcCompPtName    SnmpAdminString,
  3160.  vrcCompPtCapacity    Integer32,
  3161.  vrcCompPtRunTimeHours    Integer32,
  3162.  vrcCompPtStartStopCount    Integer32,
  3163.  vrcCompPtDriverFaultU00    TruthValue,
  3164.  vrcCompPtDriverFaultU01    TruthValue,
  3165.  vrcCompPtDriverFaultU02    TruthValue,
  3166.  vrcCompPtDriverFaultU03    TruthValue,
  3167.  vrcCompPtDriverFaultU04    TruthValue,
  3168.  vrcCompPtDriverFaultU05    TruthValue,
  3169.  vrcCompPtDriverFaultU06    TruthValue,
  3170.  vrcCompPtDriverFaultU07    TruthValue,
  3171.  vrcCompPtDriverFaultU08    TruthValue,
  3172.  vrcCompPtDriverFaultU09    TruthValue,
  3173.  vrcCompPtDriverFaultU10    TruthValue,
  3174.  vrcCompPtDriverFaultU11    TruthValue,
  3175.  vrcCompPtDriverFaultU12    TruthValue,
  3176.  vrcCompPtDriverFaultU13    TruthValue,
  3177.  vrcCompPtDriverFaultU14    TruthValue,
  3178.  vrcCompPtDriverFaultU15    TruthValue,
  3179.  vrcCompPtDriverCommFailAlarm    TruthValue,
  3180.  vrcCompPtFaultLockAlarm    TruthValue
  3181. }
  3182.  
  3183. vrcCompPtIndex OBJECT-TYPE
  3184.  SYNTAX Integer32(1..100)
  3185.  MAX-ACCESS not-accessible
  3186.  STATUS current
  3187.  DESCRIPTION
  3188.   "Unique id for each entry in the table"
  3189.  ::= { vrcCompPtEntry 1 }
  3190.  
  3191. vrcCompPtName OBJECT-TYPE
  3192.  SYNTAX SnmpAdminString(SIZE (1..25))
  3193.  MAX-ACCESS read-only
  3194.  STATUS current
  3195.  DESCRIPTION
  3196.   "Compressor name (factory-assigned)"
  3197.  ::= { vrcCompPtEntry 2 }
  3198.  
  3199. vrcCompPtCapacity OBJECT-TYPE
  3200.  SYNTAX Integer32(0..100)
  3201.  UNITS "%"
  3202.  MAX-ACCESS read-only
  3203.  STATUS current
  3204.  DESCRIPTION
  3205.   "Compressor capacity value (percent)"
  3206.  ::= { vrcCompPtEntry 3 }
  3207.  
  3208. vrcCompPtRunTimeHours OBJECT-TYPE
  3209.  SYNTAX Integer32(-32768..32767)
  3210.  UNITS "hours"
  3211.  MAX-ACCESS read-only
  3212.  STATUS current
  3213.  DESCRIPTION
  3214.   "Compressor run time in hours"
  3215.  ::= { vrcCompPtEntry 4 }
  3216.  
  3217. vrcCompPtStartStopCount OBJECT-TYPE
  3218.  SYNTAX Integer32(-32768..32767)
  3219.  MAX-ACCESS read-only
  3220.  STATUS current
  3221.  DESCRIPTION
  3222.   "Compressor start/stop count"
  3223.  ::= { vrcCompPtEntry 5 }
  3224.  
  3225. vrcCompPtDriverFaultU00 OBJECT-TYPE
  3226.  SYNTAX TruthValue
  3227.  MAX-ACCESS read-only
  3228.  STATUS current
  3229.  DESCRIPTION
  3230.   "Compressor driver fault alarm U00 state"
  3231.  ::= { vrcCompPtEntry 6 }
  3232.  
  3233. vrcCompPtDriverFaultU01 OBJECT-TYPE
  3234.  SYNTAX TruthValue
  3235.  MAX-ACCESS read-only
  3236.  STATUS current
  3237.  DESCRIPTION
  3238.   "Compressor driver fault alarm U01 state"
  3239.  ::= { vrcCompPtEntry 7 }
  3240.  
  3241. vrcCompPtDriverFaultU02 OBJECT-TYPE
  3242.  SYNTAX TruthValue
  3243.  MAX-ACCESS read-only
  3244.  STATUS current
  3245.  DESCRIPTION
  3246.   "Compressor driver fault alarm U02 state"
  3247.  ::= { vrcCompPtEntry 8 }
  3248.  
  3249. vrcCompPtDriverFaultU03 OBJECT-TYPE
  3250.  SYNTAX TruthValue
  3251.  MAX-ACCESS read-only
  3252.  STATUS current
  3253.  DESCRIPTION
  3254.   "Compressor driver fault alarm U03 state"
  3255.  ::= { vrcCompPtEntry 9 }
  3256.  
  3257. vrcCompPtDriverFaultU04 OBJECT-TYPE
  3258.  SYNTAX TruthValue
  3259.  MAX-ACCESS read-only
  3260.  STATUS current
  3261.  DESCRIPTION
  3262.   "Compressor driver fault alarm U04 state"
  3263.  ::= { vrcCompPtEntry 10 }
  3264.  
  3265. vrcCompPtDriverFaultU05 OBJECT-TYPE
  3266.  SYNTAX TruthValue
  3267.  MAX-ACCESS read-only
  3268.  STATUS current
  3269.  DESCRIPTION
  3270.   "Compressor driver fault alarm U05 state"
  3271.  ::= { vrcCompPtEntry 11 }
  3272.  
  3273. vrcCompPtDriverFaultU06 OBJECT-TYPE
  3274.  SYNTAX TruthValue
  3275.  MAX-ACCESS read-only
  3276.  STATUS current
  3277.  DESCRIPTION
  3278.   "Compressor driver fault alarm U06 state"
  3279.  ::= { vrcCompPtEntry 12 }
  3280.  
  3281. vrcCompPtDriverFaultU07 OBJECT-TYPE
  3282.  SYNTAX TruthValue
  3283.  MAX-ACCESS read-only
  3284.  STATUS current
  3285.  DESCRIPTION
  3286.   "Compressor driver fault alarm U07 state"
  3287.  ::= { vrcCompPtEntry 13 }
  3288.  
  3289. vrcCompPtDriverFaultU08 OBJECT-TYPE
  3290.  SYNTAX TruthValue
  3291.  MAX-ACCESS read-only
  3292.  STATUS current
  3293.  DESCRIPTION
  3294.   "Compressor driver fault alarm U08 state"
  3295.  ::= { vrcCompPtEntry 14 }
  3296.  
  3297. vrcCompPtDriverFaultU09 OBJECT-TYPE
  3298.  SYNTAX TruthValue
  3299.  MAX-ACCESS read-only
  3300.  STATUS current
  3301.  DESCRIPTION
  3302.   "Compressor driver fault alarm U09 state"
  3303.  ::= { vrcCompPtEntry 15 }
  3304.  
  3305. vrcCompPtDriverFaultU10 OBJECT-TYPE
  3306.  SYNTAX TruthValue
  3307.  MAX-ACCESS read-only
  3308.  STATUS current
  3309.  DESCRIPTION
  3310.   "Compressor driver fault alarm U10 state"
  3311.  ::= { vrcCompPtEntry 16 }
  3312.  
  3313. vrcCompPtDriverFaultU11 OBJECT-TYPE
  3314.  SYNTAX TruthValue
  3315.  MAX-ACCESS read-only
  3316.  STATUS current
  3317.  DESCRIPTION
  3318.   "Compressor driver fault alarm U11 state"
  3319.  ::= { vrcCompPtEntry 17 }
  3320.  
  3321. vrcCompPtDriverFaultU12 OBJECT-TYPE
  3322.  SYNTAX TruthValue
  3323.  MAX-ACCESS read-only
  3324.  STATUS current
  3325.  DESCRIPTION
  3326.   "Compressor driver fault alarm U12 state"
  3327.  ::= { vrcCompPtEntry 18 }
  3328.  
  3329. vrcCompPtDriverFaultU13 OBJECT-TYPE
  3330.  SYNTAX TruthValue
  3331.  MAX-ACCESS read-only
  3332.  STATUS current
  3333.  DESCRIPTION
  3334.   "Compressor driver fault alarm U13 state"
  3335.  ::= { vrcCompPtEntry 19 }
  3336.  
  3337. vrcCompPtDriverFaultU14 OBJECT-TYPE
  3338.  SYNTAX TruthValue
  3339.  MAX-ACCESS read-only
  3340.  STATUS current
  3341.  DESCRIPTION
  3342.   "Compressor driver fault alarm U14 state"
  3343.  ::= { vrcCompPtEntry 20 }
  3344.  
  3345. vrcCompPtDriverFaultU15 OBJECT-TYPE
  3346.  SYNTAX TruthValue
  3347.  MAX-ACCESS read-only
  3348.  STATUS current
  3349.  DESCRIPTION
  3350.   "Compressor driver fault alarm U15 state"
  3351.  ::= { vrcCompPtEntry 21 }
  3352.  
  3353. vrcCompPtDriverCommFailAlarm OBJECT-TYPE
  3354.  SYNTAX TruthValue
  3355.  MAX-ACCESS read-only
  3356.  STATUS current
  3357.  DESCRIPTION
  3358.   "Compressor driver communication failure alarm state"
  3359.  ::= { vrcCompPtEntry 22 }
  3360.  
  3361. vrcCompPtFaultLockAlarm OBJECT-TYPE
  3362.  SYNTAX TruthValue
  3363.  MAX-ACCESS read-only
  3364.  STATUS current
  3365.  DESCRIPTION
  3366.   "Compressor fault lock alarm state"
  3367.  ::= { vrcCompPtEntry 23 }
  3368.  
  3369. --###########################################################################################--
  3370. --vrcCompCfgTable--
  3371. --###########################################################################################--
  3372.  
  3373. vrcCompCfgTable OBJECT-TYPE
  3374.  SYNTAX SEQUENCE OF VrcCompCfgEntry
  3375.  MAX-ACCESS  not-accessible
  3376.  STATUS current
  3377.  DESCRIPTION
  3378.   "Table used for VRC compressor configuration"
  3379.  ::= { vrc 9 }
  3380.  
  3381. vrcCompCfgEntry OBJECT-TYPE
  3382.  SYNTAX VrcCompCfgEntry
  3383.  MAX-ACCESS  not-accessible
  3384.  STATUS current
  3385.  DESCRIPTION
  3386.   "Entry in the vrcCompCfgTable: each entry contains config fields for a
  3387.   VRC compressor"
  3388.  INDEX { vrcCompCfgIndex }
  3389.  ::= { vrcCompCfgTable 1 }
  3390.  
  3391. VrcCompCfgEntry ::= SEQUENCE {
  3392.  vrcCompCfgIndex    Integer32,
  3393.  vrcCompCfgOutputStatus    TruthValue,
  3394.  vrcCompCfgOutputDeadBand    Integer32,
  3395.  vrcCompCfgCapacityOutputValue    Integer32,
  3396.  vrcCompCfgMinCapacity    Integer32,
  3397.  vrcCompCfgStartCapacity    Integer32,
  3398.  vrcCompCfgStandardCapacity    Integer32,
  3399.  vrcCompCfgStartCfc    Integer32,
  3400.  vrcCompCfgStopCfc    Integer32,
  3401.  vrcCompCfgMinRunTime    Integer32,
  3402.  vrcCompCfgMinStopTime    Integer32,
  3403.  vrcCompCfgJumpBand1    Integer32,
  3404.  vrcCompCfgJumpBand2    Integer32,
  3405.  vrcCompCfgJumpBand3    Integer32,
  3406.  vrcCompCfgJumpBand4    Integer32,
  3407.  vrcCompCfgJumpBand5    Integer32,
  3408.  vrcCompCfgJumpFreq1    Integer32,
  3409.  vrcCompCfgJumpFreq2    Integer32,
  3410.  vrcCompCfgJumpFreq3    Integer32,
  3411.  vrcCompCfgJumpFreq4    Integer32,
  3412.  vrcCompCfgJumpFreq5    Integer32,
  3413.  vrcCompCfgTempP    Integer32,
  3414.  vrcCompCfgTempI    Integer32,
  3415.  vrcCompCfgTempD    Integer32,
  3416.  vrcCompCfgDriverFaultAlmCtrl    INTEGER,
  3417.  vrcCompCfgDriverCommFailAlmCtrl    INTEGER,
  3418.  vrcCompCfgFaultLockAlmCtrl    INTEGER
  3419. }
  3420.  
  3421. vrcCompCfgIndex OBJECT-TYPE
  3422.  SYNTAX Integer32(1..100)
  3423.  MAX-ACCESS not-accessible
  3424.  STATUS current
  3425.  DESCRIPTION
  3426.   "Unique id for each entry in the table"
  3427.  ::= { vrcCompCfgEntry 1 }
  3428.  
  3429. vrcCompCfgOutputStatus OBJECT-TYPE
  3430.  SYNTAX TruthValue
  3431.  MAX-ACCESS read-write
  3432.  STATUS current
  3433.  DESCRIPTION
  3434.   "Compressor output status"
  3435.  ::= { vrcCompCfgEntry 2 }
  3436.  
  3437. vrcCompCfgOutputDeadBand OBJECT-TYPE
  3438.  SYNTAX Integer32(0..50)
  3439.  UNITS "0.1%"
  3440.  MAX-ACCESS read-write
  3441.  STATUS current
  3442.  DESCRIPTION
  3443.   "Compressor output dead band in tenths of a percent"
  3444.  ::= { vrcCompCfgEntry 3 }
  3445.  
  3446. vrcCompCfgCapacityOutputValue OBJECT-TYPE
  3447.  SYNTAX Integer32(0..100)
  3448.  UNITS "%"
  3449.  MAX-ACCESS read-write
  3450.  STATUS current
  3451.  DESCRIPTION
  3452.   "Compressor capacity output (percent)"
  3453.  ::= { vrcCompCfgEntry 4 }
  3454.  
  3455. vrcCompCfgMinCapacity OBJECT-TYPE
  3456.  SYNTAX Integer32(15..50)
  3457.  UNITS "%"
  3458.  MAX-ACCESS read-write
  3459.  STATUS current
  3460.  DESCRIPTION
  3461.   "Compressor min capacity (percent)"
  3462.  ::= { vrcCompCfgEntry 5 }
  3463.  
  3464. vrcCompCfgStartCapacity OBJECT-TYPE
  3465.  SYNTAX Integer32(40..100)
  3466.  UNITS "%"
  3467.  MAX-ACCESS read-write
  3468.  STATUS current
  3469.  DESCRIPTION
  3470.   "Compressor start capacity (percent)"
  3471.  ::= { vrcCompCfgEntry 6 }
  3472.  
  3473. vrcCompCfgStandardCapacity OBJECT-TYPE
  3474.  SYNTAX Integer32(80..100)
  3475.  UNITS "%"
  3476.  MAX-ACCESS read-write
  3477.  STATUS current
  3478.  DESCRIPTION
  3479.   "Compressor standard capacity (percent)"
  3480.  ::= { vrcCompCfgEntry 7 }
  3481.  
  3482. vrcCompCfgStartCfc OBJECT-TYPE
  3483.  SYNTAX Integer32(1..100)
  3484.  UNITS "%"
  3485.  MAX-ACCESS read-write
  3486.  STATUS current
  3487.  DESCRIPTION
  3488.   "Compressor start cfc (percent)"
  3489.  ::= { vrcCompCfgEntry 8 }
  3490.  
  3491. vrcCompCfgStopCfc OBJECT-TYPE
  3492.  SYNTAX Integer32(-200..-50)
  3493.  UNITS "%"
  3494.  MAX-ACCESS read-write
  3495.  STATUS current
  3496.  DESCRIPTION
  3497.   "Compressor stop cfc (percent)"
  3498.  ::= { vrcCompCfgEntry 9 }
  3499.  
  3500. vrcCompCfgMinRunTime OBJECT-TYPE
  3501.  SYNTAX Integer32(0..30)
  3502.  UNITS "minutes"
  3503.  MAX-ACCESS read-write
  3504.  STATUS current
  3505.  DESCRIPTION
  3506.   "Compressor min run time in minutes"
  3507.  ::= { vrcCompCfgEntry 10 }
  3508.  
  3509. vrcCompCfgMinStopTime OBJECT-TYPE
  3510.  SYNTAX Integer32(0..10)
  3511.  UNITS "minutes"
  3512.  MAX-ACCESS read-write
  3513.  STATUS current
  3514.  DESCRIPTION
  3515.   "Compressor min stop time in minutes"
  3516.  ::= { vrcCompCfgEntry 11 }
  3517.  
  3518. vrcCompCfgJumpBand1 OBJECT-TYPE
  3519.  SYNTAX Integer32(0..100)
  3520.  UNITS "0.1%"
  3521.  MAX-ACCESS read-write
  3522.  STATUS current
  3523.  DESCRIPTION
  3524.   "Compressor jump band 1 in tenths of a percent"
  3525.  ::= { vrcCompCfgEntry 12 }
  3526.  
  3527. vrcCompCfgJumpBand2 OBJECT-TYPE
  3528.  SYNTAX Integer32(0..100)
  3529.  UNITS "0.1%"
  3530.  MAX-ACCESS read-write
  3531.  STATUS current
  3532.  DESCRIPTION
  3533.   "Compressor jump band 2 in tenths of a percent"
  3534.  ::= { vrcCompCfgEntry 13 }
  3535.  
  3536. vrcCompCfgJumpBand3 OBJECT-TYPE
  3537.  SYNTAX Integer32(0..100)
  3538.  UNITS "0.1%"
  3539.  MAX-ACCESS read-write
  3540.  STATUS current
  3541.  DESCRIPTION
  3542.   "Compressor jump band 3 in tenths of a percent"
  3543.  ::= { vrcCompCfgEntry 14 }
  3544.  
  3545. vrcCompCfgJumpBand4 OBJECT-TYPE
  3546.  SYNTAX Integer32(0..100)
  3547.  UNITS "0.1%"
  3548.  MAX-ACCESS read-write
  3549.  STATUS current
  3550.  DESCRIPTION
  3551.   "Compressor jump band 4 in tenths of a percent"
  3552.  ::= { vrcCompCfgEntry 15 }
  3553.  
  3554. vrcCompCfgJumpBand5 OBJECT-TYPE
  3555.  SYNTAX Integer32(0..100)
  3556.  UNITS "0.1%"
  3557.  MAX-ACCESS read-write
  3558.  STATUS current
  3559.  DESCRIPTION
  3560.   "Compressor jump band 5 in tenths of a percent"
  3561.  ::= { vrcCompCfgEntry 16 }
  3562.  
  3563. vrcCompCfgJumpFreq1 OBJECT-TYPE
  3564.  SYNTAX Integer32(0..1000)
  3565.  UNITS "0.1%"
  3566.  MAX-ACCESS read-write
  3567.  STATUS current
  3568.  DESCRIPTION
  3569.   "Compressor jump frequency 1 in tenths of a percent"
  3570.  ::= { vrcCompCfgEntry 17 }
  3571.  
  3572. vrcCompCfgJumpFreq2 OBJECT-TYPE
  3573.  SYNTAX Integer32(0..1000)
  3574.  UNITS "0.1%"
  3575.  MAX-ACCESS read-write
  3576.  STATUS current
  3577.  DESCRIPTION
  3578.   "Compressor jump frequency 2 in tenths of a percent"
  3579.  ::= { vrcCompCfgEntry 18 }
  3580.  
  3581. vrcCompCfgJumpFreq3 OBJECT-TYPE
  3582.  SYNTAX Integer32(0..1000)
  3583.  UNITS "0.1%"
  3584.  MAX-ACCESS read-write
  3585.  STATUS current
  3586.  DESCRIPTION
  3587.   "Compressor jump frequency 3 in tenths of a percent"
  3588.  ::= { vrcCompCfgEntry 19 }
  3589.  
  3590. vrcCompCfgJumpFreq4 OBJECT-TYPE
  3591.  SYNTAX Integer32(0..1000)
  3592.  UNITS "0.1%"
  3593.  MAX-ACCESS read-write
  3594.  STATUS current
  3595.  DESCRIPTION
  3596.   "Compressor jump frequency 4 in tenths of a percent"
  3597.  ::= { vrcCompCfgEntry 20 }
  3598.  
  3599. vrcCompCfgJumpFreq5 OBJECT-TYPE
  3600.  SYNTAX Integer32(0..1000)
  3601.  UNITS "0.1%"
  3602.  MAX-ACCESS read-write
  3603.  STATUS current
  3604.  DESCRIPTION
  3605.   "Compressor jump frequency 5 in tenths of a percent"
  3606.  ::= { vrcCompCfgEntry 21 }
  3607.  
  3608. vrcCompCfgTempP OBJECT-TYPE
  3609.  SYNTAX Integer32
  3610.  UNITS "decidegrees"
  3611.  MAX-ACCESS read-write
  3612.  STATUS current
  3613.  DESCRIPTION
  3614.   "Compressor temperature P in tenths of a degree. Units are given by
  3615.   temperatureUnits field in deviceInfo. The settable range is determined
  3616.   by the current temperature units.
  3617.   Celsius:    10 to 150
  3618.   Fahrenheit: 18 to 269"
  3619.  ::= { vrcCompCfgEntry 22 }
  3620.  
  3621. vrcCompCfgTempI OBJECT-TYPE
  3622.  SYNTAX Integer32(0..900)
  3623.  UNITS "seconds"
  3624.  MAX-ACCESS read-write
  3625.  STATUS current
  3626.  DESCRIPTION
  3627.   "Compressor temperature I in seconds"
  3628.  ::= { vrcCompCfgEntry 23 }
  3629.  
  3630. vrcCompCfgTempD OBJECT-TYPE
  3631.  SYNTAX Integer32(0..900)
  3632.  UNITS "seconds"
  3633.  MAX-ACCESS read-write
  3634.  STATUS current
  3635.  DESCRIPTION
  3636.   "Compressor temperature D in seconds"
  3637.  ::= { vrcCompCfgEntry 24 }
  3638.  
  3639. vrcCompCfgDriverFaultAlmCtrl OBJECT-TYPE
  3640.  SYNTAX INTEGER {
  3641.    suspend(2),
  3642.    open(3)
  3643.    }
  3644.  MAX-ACCESS read-write
  3645.  STATUS current
  3646.  DESCRIPTION
  3647.   "Compressor driver fault alarm control:
  3648.   2 = suspend
  3649.   3 = open"
  3650.  ::= { vrcCompCfgEntry 25 }
  3651.  
  3652. vrcCompCfgDriverCommFailAlmCtrl OBJECT-TYPE
  3653.  SYNTAX INTEGER {
  3654.    suspend(2),
  3655.    open(3)
  3656.    }
  3657.  MAX-ACCESS read-write
  3658.  STATUS current
  3659.  DESCRIPTION
  3660.   "Compressor driver communication failure alarm control:
  3661.   2 = suspend
  3662.   3 = open"
  3663.  ::= { vrcCompCfgEntry 26 }
  3664.  
  3665. vrcCompCfgFaultLockAlmCtrl OBJECT-TYPE
  3666.  SYNTAX INTEGER {
  3667.    suspend(2),
  3668.    open(3)
  3669.    }
  3670.  MAX-ACCESS read-write
  3671.  STATUS current
  3672.  DESCRIPTION
  3673.   "Compressor fault lock alarm control:
  3674.   2 = suspend
  3675.   3 = open"
  3676.  ::= { vrcCompCfgEntry 27 }
  3677.  
  3678. --###########################################################################################--
  3679. --vrcReturnPtTable--
  3680. --###########################################################################################--
  3681.  
  3682. vrcReturnPtTable OBJECT-TYPE
  3683.  SYNTAX SEQUENCE OF VrcReturnPtEntry
  3684.  MAX-ACCESS  not-accessible
  3685.  STATUS current
  3686.  DESCRIPTION
  3687.   "Table that contains VRC return status"
  3688.  ::= { vrc 10 }
  3689.  
  3690. vrcReturnPtEntry OBJECT-TYPE
  3691.  SYNTAX VrcReturnPtEntry
  3692.  MAX-ACCESS  not-accessible
  3693.  STATUS current
  3694.  DESCRIPTION
  3695.   "Entry in the vrcReturnPtTable: each entry represents return data for a
  3696.   VRC"
  3697.  INDEX { vrcReturnPtIndex }
  3698.  ::= { vrcReturnPtTable 1 }
  3699.  
  3700. VrcReturnPtEntry ::= SEQUENCE {
  3701.  vrcReturnPtIndex    Integer32,
  3702.  vrcReturnPtName    SnmpAdminString,
  3703.  vrcReturnPtTemp    Integer32,
  3704.  vrcReturnPtHighTempAlarm    TruthValue,
  3705.  vrcReturnPtTempSensorFailAlarm    TruthValue
  3706. }
  3707.  
  3708. vrcReturnPtIndex OBJECT-TYPE
  3709.  SYNTAX Integer32(1..100)
  3710.  MAX-ACCESS not-accessible
  3711.  STATUS current
  3712.  DESCRIPTION
  3713.   "Unique id for each entry in the table"
  3714.  ::= { vrcReturnPtEntry 1 }
  3715.  
  3716. vrcReturnPtName OBJECT-TYPE
  3717.  SYNTAX SnmpAdminString(SIZE (1..25))
  3718.  MAX-ACCESS read-only
  3719.  STATUS current
  3720.  DESCRIPTION
  3721.   "Return name (factory-assigned)"
  3722.  ::= { vrcReturnPtEntry 2 }
  3723.  
  3724. vrcReturnPtTemp OBJECT-TYPE
  3725.  SYNTAX Integer32
  3726.  UNITS "decidegrees"
  3727.  MAX-ACCESS read-only
  3728.  STATUS current
  3729.  DESCRIPTION
  3730.   "Return temperature value in tenths of a degree. Units are given by
  3731.   temperatureUnits field in deviceInfo. The range is determined by the
  3732.   current temperature units.
  3733.   Celsius:    -400 to 1000
  3734.   Fahrenheit: -400 to 2120"
  3735.  ::= { vrcReturnPtEntry 3 }
  3736.  
  3737. vrcReturnPtHighTempAlarm OBJECT-TYPE
  3738.  SYNTAX TruthValue
  3739.  MAX-ACCESS read-only
  3740.  STATUS current
  3741.  DESCRIPTION
  3742.   "Return high temperature alarm state"
  3743.  ::= { vrcReturnPtEntry 4 }
  3744.  
  3745. vrcReturnPtTempSensorFailAlarm OBJECT-TYPE
  3746.  SYNTAX TruthValue
  3747.  MAX-ACCESS read-only
  3748.  STATUS current
  3749.  DESCRIPTION
  3750.   "Return temperature sensor failure alarm state"
  3751.  ::= { vrcReturnPtEntry 5 }
  3752.  
  3753. --###########################################################################################--
  3754. --vrcReturnCfgTable--
  3755. --###########################################################################################--
  3756.  
  3757. vrcReturnCfgTable OBJECT-TYPE
  3758.  SYNTAX SEQUENCE OF VrcReturnCfgEntry
  3759.  MAX-ACCESS  not-accessible
  3760.  STATUS current
  3761.  DESCRIPTION
  3762.   "Table used for VRC return configuration"
  3763.  ::= { vrc 11 }
  3764.  
  3765. vrcReturnCfgEntry OBJECT-TYPE
  3766.  SYNTAX VrcReturnCfgEntry
  3767.  MAX-ACCESS  not-accessible
  3768.  STATUS current
  3769.  DESCRIPTION
  3770.   "Entry in the vrcReturnCfgTable: each entry contains config fields for
  3771.   VRC return"
  3772.  INDEX { vrcReturnCfgIndex }
  3773.  ::= { vrcReturnCfgTable 1 }
  3774.  
  3775. VrcReturnCfgEntry ::= SEQUENCE {
  3776.  vrcReturnCfgIndex    Integer32,
  3777.  vrcReturnCfgOilCycle    Integer32,
  3778.  vrcReturnCfgOilRunCapacity    Integer32,
  3779.  vrcReturnCfgOilRunTime    Integer32,
  3780.  vrcReturnCfgTempCalValue    Integer32,
  3781.  vrcReturnCfgTempSetting    Integer32,
  3782.  vrcReturnCfgHighTempAlarmValue    Integer32,
  3783.  vrcReturnCfgHighTempAlarmCtrl    INTEGER,
  3784.  vrcReturnCfgTempSensFailAlmCtrl    INTEGER
  3785. }
  3786.  
  3787. vrcReturnCfgIndex OBJECT-TYPE
  3788.  SYNTAX Integer32(1..100)
  3789.  MAX-ACCESS not-accessible
  3790.  STATUS current
  3791.  DESCRIPTION
  3792.   "Unique id for each entry in the table"
  3793.  ::= { vrcReturnCfgEntry 1 }
  3794.  
  3795. vrcReturnCfgOilCycle OBJECT-TYPE
  3796.  SYNTAX Integer32(5..50)
  3797.  UNITS "decihours"
  3798.  MAX-ACCESS read-write
  3799.  STATUS current
  3800.  DESCRIPTION
  3801.   "Return oil cycle in tenths of an hour"
  3802.  ::= { vrcReturnCfgEntry 2 }
  3803.  
  3804. vrcReturnCfgOilRunCapacity OBJECT-TYPE
  3805.  SYNTAX Integer32(50..100)
  3806.  UNITS "%"
  3807.  MAX-ACCESS read-write
  3808.  STATUS current
  3809.  DESCRIPTION
  3810.   "Return Oil run capacity (percent)"
  3811.  ::= { vrcReturnCfgEntry 3 }
  3812.  
  3813. vrcReturnCfgOilRunTime OBJECT-TYPE
  3814.  SYNTAX Integer32(0..10)
  3815.  UNITS "minutes"
  3816.  MAX-ACCESS read-write
  3817.  STATUS current
  3818.  DESCRIPTION
  3819.   "Return oil run time in minutes"
  3820.  ::= { vrcReturnCfgEntry 4 }
  3821.  
  3822. vrcReturnCfgTempCalValue OBJECT-TYPE
  3823.  SYNTAX Integer32
  3824.  UNITS "decidegrees"
  3825.  MAX-ACCESS read-write
  3826.  STATUS current
  3827.  DESCRIPTION
  3828.   "Return temperature calibration value in tenths of a degree. Units are
  3829.   given by temperatureUnits field in deviceInfo. The settable range is
  3830.   determined by the current temperature units.
  3831.   Celsius:    -100 to 100
  3832.   Fahrenheit: -179 to 179"
  3833.  ::= { vrcReturnCfgEntry 5 }
  3834.  
  3835. vrcReturnCfgTempSetting OBJECT-TYPE
  3836.  SYNTAX Integer32
  3837.  UNITS "decidegrees"
  3838.  MAX-ACCESS read-write
  3839.  STATUS current
  3840.  DESCRIPTION
  3841.   "Return temperature setting in tenths of a degree. Units are given by
  3842.   temperatureUnits field in deviceInfo. The settable range is determined
  3843.   by the current temperature units.
  3844.   Celsius:    250 to 350
  3845.   Fahrenheit: 770 to 949"
  3846.  ::= { vrcReturnCfgEntry 6 }
  3847.  
  3848. vrcReturnCfgHighTempAlarmValue OBJECT-TYPE
  3849.  SYNTAX Integer32
  3850.  UNITS "decidegrees"
  3851.  MAX-ACCESS read-write
  3852.  STATUS current
  3853.  DESCRIPTION
  3854.   "Return high temperature alarm value in tenths of a degree. Units are
  3855.   given by temperatureUnits field in deviceInfo. The settable range is
  3856.   determined by the current temperature units.
  3857.   Celsius:    300 to 450
  3858.   Fahrenheit: 860 to 1129"
  3859.  ::= { vrcReturnCfgEntry 7 }
  3860.  
  3861. vrcReturnCfgHighTempAlarmCtrl OBJECT-TYPE
  3862.  SYNTAX INTEGER {
  3863.    close(1),
  3864.    suspend(2),
  3865.    open(3)
  3866.    }
  3867.  MAX-ACCESS read-write
  3868.  STATUS current
  3869.  DESCRIPTION
  3870.   "Return high temperature alarm control:
  3871.   1 = close
  3872.   2 = suspend
  3873.   3 = open"
  3874.  ::= { vrcReturnCfgEntry 8 }
  3875.  
  3876. vrcReturnCfgTempSensFailAlmCtrl OBJECT-TYPE
  3877.  SYNTAX INTEGER {
  3878.    close(1),
  3879.    suspend(2),
  3880.    open(3)
  3881.    }
  3882.  MAX-ACCESS read-write
  3883.  STATUS current
  3884.  DESCRIPTION
  3885.   "Return temperature sensor failure alarm control:
  3886.   1 = close
  3887.   2 = suspend
  3888.   3 = open"
  3889.  ::= { vrcReturnCfgEntry 9 }
  3890.  
  3891. --###########################################################################################--
  3892. --vrcSupplyPtTable--
  3893. --###########################################################################################--
  3894.  
  3895. vrcSupplyPtTable OBJECT-TYPE
  3896.  SYNTAX SEQUENCE OF VrcSupplyPtEntry
  3897.  MAX-ACCESS  not-accessible
  3898.  STATUS current
  3899.  DESCRIPTION
  3900.   "Table that contains VRC supply status"
  3901.  ::= { vrc 12 }
  3902.  
  3903. vrcSupplyPtEntry OBJECT-TYPE
  3904.  SYNTAX VrcSupplyPtEntry
  3905.  MAX-ACCESS  not-accessible
  3906.  STATUS current
  3907.  DESCRIPTION
  3908.   "Entry in the vrcSupplyPtTable: each entry represents supply data for a
  3909.   VRC"
  3910.  INDEX { vrcSupplyPtIndex }
  3911.  ::= { vrcSupplyPtTable 1 }
  3912.  
  3913. VrcSupplyPtEntry ::= SEQUENCE {
  3914.  vrcSupplyPtIndex    Integer32,
  3915.  vrcSupplyPtName    SnmpAdminString,
  3916.  vrcSupplyPtTemp    Integer32,
  3917.  vrcSupplyPtLowTempAlarm    TruthValue,
  3918.  vrcSupplyPtHighTempAlarm    TruthValue,
  3919.  vrcSupplyPtTempSensorFailAlarm    TruthValue
  3920. }
  3921.  
  3922. vrcSupplyPtIndex OBJECT-TYPE
  3923.  SYNTAX Integer32(1..100)
  3924.  MAX-ACCESS not-accessible
  3925.  STATUS current
  3926.  DESCRIPTION
  3927.   "Unique id for each entry in the table"
  3928.  ::= { vrcSupplyPtEntry 1 }
  3929.  
  3930. vrcSupplyPtName OBJECT-TYPE
  3931.  SYNTAX SnmpAdminString(SIZE (1..25))
  3932.  MAX-ACCESS read-only
  3933.  STATUS current
  3934.  DESCRIPTION
  3935.   "Supply name (factory-assigned)"
  3936.  ::= { vrcSupplyPtEntry 2 }
  3937.  
  3938. vrcSupplyPtTemp OBJECT-TYPE
  3939.  SYNTAX Integer32
  3940.  UNITS "decidegrees"
  3941.  MAX-ACCESS read-only
  3942.  STATUS current
  3943.  DESCRIPTION
  3944.   "Supply temperature value in tenths of a degree. Units are given by
  3945.   temperatureUnits field in deviceInfo. The range is determined by the
  3946.   current temperature units.
  3947.   Celsius:    -400 to 1000
  3948.   Fahrenheit: -400 to 2120"
  3949.  ::= { vrcSupplyPtEntry 3 }
  3950.  
  3951. vrcSupplyPtLowTempAlarm OBJECT-TYPE
  3952.  SYNTAX TruthValue
  3953.  MAX-ACCESS read-only
  3954.  STATUS current
  3955.  DESCRIPTION
  3956.   "Supply low temperature alarm state"
  3957.  ::= { vrcSupplyPtEntry 4 }
  3958.  
  3959. vrcSupplyPtHighTempAlarm OBJECT-TYPE
  3960.  SYNTAX TruthValue
  3961.  MAX-ACCESS read-only
  3962.  STATUS current
  3963.  DESCRIPTION
  3964.   "Supply high temperature alarm state"
  3965.  ::= { vrcSupplyPtEntry 5 }
  3966.  
  3967. vrcSupplyPtTempSensorFailAlarm OBJECT-TYPE
  3968.  SYNTAX TruthValue
  3969.  MAX-ACCESS read-only
  3970.  STATUS current
  3971.  DESCRIPTION
  3972.   "Supply temperature sensor failure alarm state"
  3973.  ::= { vrcSupplyPtEntry 6 }
  3974.  
  3975. --###########################################################################################--
  3976. --vrcSupplyCfgTable--
  3977. --###########################################################################################--
  3978.  
  3979. vrcSupplyCfgTable OBJECT-TYPE
  3980.  SYNTAX SEQUENCE OF VrcSupplyCfgEntry
  3981.  MAX-ACCESS  not-accessible
  3982.  STATUS current
  3983.  DESCRIPTION
  3984.   "Table used for VRC supply configuration"
  3985.  ::= { vrc 13 }
  3986.  
  3987. vrcSupplyCfgEntry OBJECT-TYPE
  3988.  SYNTAX VrcSupplyCfgEntry
  3989.  MAX-ACCESS  not-accessible
  3990.  STATUS current
  3991.  DESCRIPTION
  3992.   "Entry in the vrcSupplyCfgTable: each entry contains config fields for
  3993.   a VRC supply"
  3994.  INDEX { vrcSupplyCfgIndex }
  3995.  ::= { vrcSupplyCfgTable 1 }
  3996.  
  3997. VrcSupplyCfgEntry ::= SEQUENCE {
  3998.  vrcSupplyCfgIndex    Integer32,
  3999.  vrcSupplyCfgTempCalValue    Integer32,
  4000.  vrcSupplyCfgTempSetting    Integer32,
  4001.  vrcSupplyCfgLowTempAlarmValue    Integer32,
  4002.  vrcSupplyCfgHighTempAlarmValue    Integer32,
  4003.  vrcSupplyCfgLowTempAlmCtrl    INTEGER,
  4004.  vrcSupplyCfgHighTempAlmCtrl    INTEGER,
  4005.  vrcSupplyCfgTempSensFailAlmCtrl    INTEGER
  4006. }
  4007.  
  4008. vrcSupplyCfgIndex OBJECT-TYPE
  4009.  SYNTAX Integer32(1..100)
  4010.  MAX-ACCESS not-accessible
  4011.  STATUS current
  4012.  DESCRIPTION
  4013.   "Unique id for each entry in the table"
  4014.  ::= { vrcSupplyCfgEntry 1 }
  4015.  
  4016. vrcSupplyCfgTempCalValue OBJECT-TYPE
  4017.  SYNTAX Integer32
  4018.  UNITS "decidegrees"
  4019.  MAX-ACCESS read-write
  4020.  STATUS current
  4021.  DESCRIPTION
  4022.   "Supply temperature calibration value in tenths of a degree. Units are
  4023.   given by temperatureUnits field in deviceInfo. The settable range is
  4024.   determined by the current temperature units.
  4025.   Celsius:    -100 to 100
  4026.   Fahrenheit: -179 to 179"
  4027.  ::= { vrcSupplyCfgEntry 2 }
  4028.  
  4029. vrcSupplyCfgTempSetting OBJECT-TYPE
  4030.  SYNTAX Integer32
  4031.  UNITS "decidegrees"
  4032.  MAX-ACCESS read-write
  4033.  STATUS current
  4034.  DESCRIPTION
  4035.   "Supply temperature setting in tenths of a degree. Units are given by
  4036.   temperatureUnits field in deviceInfo. The settable range is determined
  4037.   by the current temperature units.
  4038.   Celsius:    130 to 280
  4039.   Fahrenheit: 554 to 823"
  4040.  ::= { vrcSupplyCfgEntry 3 }
  4041.  
  4042. vrcSupplyCfgLowTempAlarmValue OBJECT-TYPE
  4043.  SYNTAX Integer32
  4044.  UNITS "decidegrees"
  4045.  MAX-ACCESS read-write
  4046.  STATUS current
  4047.  DESCRIPTION
  4048.   "Supply low temperature alarm value in tenths of a degree. Units are
  4049.   given by temperatureUnits field in deviceInfo. The settable range is
  4050.   determined by the current temperature units.
  4051.   Celsius:    50 to 200
  4052.   Fahrenheit: 410 to 679"
  4053.  ::= { vrcSupplyCfgEntry 4 }
  4054.  
  4055. vrcSupplyCfgHighTempAlarmValue OBJECT-TYPE
  4056.  SYNTAX Integer32
  4057.  UNITS "decidegrees"
  4058.  MAX-ACCESS read-write
  4059.  STATUS current
  4060.  DESCRIPTION
  4061.   "Supply high temperature alarm value in tenths of a degree. Units are
  4062.   given by temperatureUnits field in deviceInfo. The settable range is
  4063.   determined by the current temperature units.
  4064.   Celsius:    200 to 350
  4065.   Fahrenheit: 680 to 949"
  4066.  ::= { vrcSupplyCfgEntry 5 }
  4067.  
  4068. vrcSupplyCfgLowTempAlmCtrl OBJECT-TYPE
  4069.  SYNTAX INTEGER {
  4070.    close(1),
  4071.    suspend(2),
  4072.    open(3)
  4073.    }
  4074.  MAX-ACCESS read-write
  4075.  STATUS current
  4076.  DESCRIPTION
  4077.   "Supply low temperature alarm control:
  4078.   1 = close
  4079.   2 = suspend
  4080.   3 = open"
  4081.  ::= { vrcSupplyCfgEntry 6 }
  4082.  
  4083. vrcSupplyCfgHighTempAlmCtrl OBJECT-TYPE
  4084.  SYNTAX INTEGER {
  4085.    close(1),
  4086.    suspend(2),
  4087.    open(3)
  4088.    }
  4089.  MAX-ACCESS read-write
  4090.  STATUS current
  4091.  DESCRIPTION
  4092.   "Supply high temperature alarm control:
  4093.   1 = close
  4094.   2 = suspend
  4095.   3 = open"
  4096.  ::= { vrcSupplyCfgEntry 7 }
  4097.  
  4098. vrcSupplyCfgTempSensFailAlmCtrl OBJECT-TYPE
  4099.  SYNTAX INTEGER {
  4100.    close(1),
  4101.    suspend(2),
  4102.    open(3)
  4103.    }
  4104.  MAX-ACCESS read-write
  4105.  STATUS current
  4106.  DESCRIPTION
  4107.   "Supply temperature sensor failure alarm control:
  4108.   1 = close
  4109.   2 = suspend
  4110.   3 = open"
  4111.  ::= { vrcSupplyCfgEntry 8 }
  4112.  
  4113. --###########################################################################################--
  4114. --vrcPowerPtTable--
  4115. --###########################################################################################--
  4116.  
  4117. vrcPowerPtTable OBJECT-TYPE
  4118.  SYNTAX SEQUENCE OF VrcPowerPtEntry
  4119.  MAX-ACCESS  not-accessible
  4120.  STATUS current
  4121.  DESCRIPTION
  4122.   "Table that contains VRC power status"
  4123.  ::= { vrc 14 }
  4124.  
  4125. vrcPowerPtEntry OBJECT-TYPE
  4126.  SYNTAX VrcPowerPtEntry
  4127.  MAX-ACCESS  not-accessible
  4128.  STATUS current
  4129.  DESCRIPTION
  4130.   "Entry in the vrcPowerPtTable: each entry represents power data for a
  4131.   VRC"
  4132.  INDEX { vrcPowerPtIndex }
  4133.  ::= { vrcPowerPtTable 1 }
  4134.  
  4135. VrcPowerPtEntry ::= SEQUENCE {
  4136.  vrcPowerPtIndex    Integer32,
  4137.  vrcPowerPtName    SnmpAdminString,
  4138.  vrcPowerPtVoltage    Integer32,
  4139.  vrcPowerPtFrequency    Integer32,
  4140.  vrcPowerPtLowVoltageAlarm    TruthValue,
  4141.  vrcPowerPtHighVoltageAlarm    TruthValue,
  4142.  vrcPowerPtLossOfPhasePowerAlarm    TruthValue,
  4143.  vrcPowerPtLossOfPowerAlarm    TruthValue,
  4144.  vrcPowerPtFrequencyErrorAlarm    TruthValue
  4145. }
  4146.  
  4147. vrcPowerPtIndex OBJECT-TYPE
  4148.  SYNTAX Integer32(1..100)
  4149.  MAX-ACCESS not-accessible
  4150.  STATUS current
  4151.  DESCRIPTION
  4152.   "Unique id for each entry in the table"
  4153.  ::= { vrcPowerPtEntry 1 }
  4154.  
  4155. vrcPowerPtName OBJECT-TYPE
  4156.  SYNTAX SnmpAdminString(SIZE (1..25))
  4157.  MAX-ACCESS read-only
  4158.  STATUS current
  4159.  DESCRIPTION
  4160.   "Power name (factory-assigned)"
  4161.  ::= { vrcPowerPtEntry 2 }
  4162.  
  4163. vrcPowerPtVoltage OBJECT-TYPE
  4164.  SYNTAX Integer32(-32768..32767)
  4165.  UNITS "decivolts"
  4166.  MAX-ACCESS read-only
  4167.  STATUS current
  4168.  DESCRIPTION
  4169.   "Power voltage measurement in tenths of a volt"
  4170.  ::= { vrcPowerPtEntry 3 }
  4171.  
  4172. vrcPowerPtFrequency OBJECT-TYPE
  4173.  SYNTAX Integer32(-32768..32767)
  4174.  UNITS "decihertz"
  4175.  MAX-ACCESS read-only
  4176.  STATUS current
  4177.  DESCRIPTION
  4178.   "Power frequency measurement in tenths of hertz"
  4179.  ::= { vrcPowerPtEntry 4 }
  4180.  
  4181. vrcPowerPtLowVoltageAlarm OBJECT-TYPE
  4182.  SYNTAX TruthValue
  4183.  MAX-ACCESS read-only
  4184.  STATUS current
  4185.  DESCRIPTION
  4186.   "Power low voltage alarm state"
  4187.  ::= { vrcPowerPtEntry 5 }
  4188.  
  4189. vrcPowerPtHighVoltageAlarm OBJECT-TYPE
  4190.  SYNTAX TruthValue
  4191.  MAX-ACCESS read-only
  4192.  STATUS current
  4193.  DESCRIPTION
  4194.   "Power high voltage alarm state"
  4195.  ::= { vrcPowerPtEntry 6 }
  4196.  
  4197. vrcPowerPtLossOfPhasePowerAlarm OBJECT-TYPE
  4198.  SYNTAX TruthValue
  4199.  MAX-ACCESS read-only
  4200.  STATUS current
  4201.  DESCRIPTION
  4202.   "Phase power loss alarm state"
  4203.  ::= { vrcPowerPtEntry 7 }
  4204.  
  4205. vrcPowerPtLossOfPowerAlarm OBJECT-TYPE
  4206.  SYNTAX TruthValue
  4207.  MAX-ACCESS read-only
  4208.  STATUS current
  4209.  DESCRIPTION
  4210.   "Power loss alarm state"
  4211.  ::= { vrcPowerPtEntry 8 }
  4212.  
  4213. vrcPowerPtFrequencyErrorAlarm OBJECT-TYPE
  4214.  SYNTAX TruthValue
  4215.  MAX-ACCESS read-only
  4216.  STATUS current
  4217.  DESCRIPTION
  4218.   "Power frequency error alarm state"
  4219.  ::= { vrcPowerPtEntry 9 }
  4220.  
  4221. --###########################################################################################--
  4222. --vrcPowerCfgTable--
  4223. --###########################################################################################--
  4224.  
  4225. vrcPowerCfgTable OBJECT-TYPE
  4226.  SYNTAX SEQUENCE OF VrcPowerCfgEntry
  4227.  MAX-ACCESS  not-accessible
  4228.  STATUS current
  4229.  DESCRIPTION
  4230.   "Table used for VRC power configuration"
  4231.  ::= { vrc 15 }
  4232.  
  4233. vrcPowerCfgEntry OBJECT-TYPE
  4234.  SYNTAX VrcPowerCfgEntry
  4235.  MAX-ACCESS  not-accessible
  4236.  STATUS current
  4237.  DESCRIPTION
  4238.   "Entry in the vrcPowerCfgTable: each entry contains config fields for
  4239.   VRC power"
  4240.  INDEX { vrcPowerCfgIndex }
  4241.  ::= { vrcPowerCfgTable 1 }
  4242.  
  4243. VrcPowerCfgEntry ::= SEQUENCE {
  4244.  vrcPowerCfgIndex    Integer32,
  4245.  vrcPowerCfgLowVoltageSetting    Integer32,
  4246.  vrcPowerCfgHighVoltageSetting    Integer32,
  4247.  vrcPowerCfgLowVoltageAlarmCtrl    INTEGER,
  4248.  vrcPowerCfgHighVoltageAlarmCtrl    INTEGER,
  4249.  vrcPowerCfgLossOfPowerAlarmCtrl    INTEGER,
  4250.  vrcPowerCfgFreqErrorAlarmCtrl    INTEGER
  4251. }
  4252.  
  4253. vrcPowerCfgIndex OBJECT-TYPE
  4254.  SYNTAX Integer32(1..100)
  4255.  MAX-ACCESS not-accessible
  4256.  STATUS current
  4257.  DESCRIPTION
  4258.   "Unique id for each entry in the table"
  4259.  ::= { vrcPowerCfgEntry 1 }
  4260.  
  4261. vrcPowerCfgLowVoltageSetting OBJECT-TYPE
  4262.  SYNTAX Integer32(100..230)
  4263.  UNITS "volts"
  4264.  MAX-ACCESS read-write
  4265.  STATUS current
  4266.  DESCRIPTION
  4267.   "Power low voltage setting in volts"
  4268.  ::= { vrcPowerCfgEntry 2 }
  4269.  
  4270. vrcPowerCfgHighVoltageSetting OBJECT-TYPE
  4271.  SYNTAX Integer32(100..300)
  4272.  UNITS "volts"
  4273.  MAX-ACCESS read-write
  4274.  STATUS current
  4275.  DESCRIPTION
  4276.   "Power high voltage setting in volts"
  4277.  ::= { vrcPowerCfgEntry 3 }
  4278.  
  4279. vrcPowerCfgLowVoltageAlarmCtrl OBJECT-TYPE
  4280.  SYNTAX INTEGER {
  4281.    close(1),
  4282.    suspend(2),
  4283.    open(3)
  4284.    }
  4285.  MAX-ACCESS read-write
  4286.  STATUS current
  4287.  DESCRIPTION
  4288.   "Power low voltage alarm control:
  4289.   1 = close
  4290.   2 = suspend
  4291.   3 = open"
  4292.  ::= { vrcPowerCfgEntry 4 }
  4293.  
  4294. vrcPowerCfgHighVoltageAlarmCtrl OBJECT-TYPE
  4295.  SYNTAX INTEGER {
  4296.    close(1),
  4297.    suspend(2),
  4298.    open(3)
  4299.    }
  4300.  MAX-ACCESS read-write
  4301.  STATUS current
  4302.  DESCRIPTION
  4303.   "Power high voltage alarm control:
  4304.   1 = close
  4305.   2 = suspend
  4306.   3 = open"
  4307.  ::= { vrcPowerCfgEntry 5 }
  4308.  
  4309. vrcPowerCfgLossOfPowerAlarmCtrl OBJECT-TYPE
  4310.  SYNTAX INTEGER {
  4311.    close(1),
  4312.    suspend(2),
  4313.    open(3)
  4314.    }
  4315.  MAX-ACCESS read-write
  4316.  STATUS current
  4317.  DESCRIPTION
  4318.   "Power loss alarm control:
  4319.   1 = close
  4320.   2 = suspend
  4321.   3 = open"
  4322.  ::= { vrcPowerCfgEntry 6 }
  4323.  
  4324. vrcPowerCfgFreqErrorAlarmCtrl OBJECT-TYPE
  4325.  SYNTAX INTEGER {
  4326.    close(1),
  4327.    suspend(2),
  4328.    open(3)
  4329.    }
  4330.  MAX-ACCESS read-write
  4331.  STATUS current
  4332.  DESCRIPTION
  4333.   "Power frequency error alarm control:
  4334.   1 = close
  4335.   2 = suspend
  4336.   3 = open"
  4337.  ::= { vrcPowerCfgEntry 7 }
  4338.  
  4339. --###########################################################################################--
  4340. --vrcOutdoorPtTable--
  4341. --###########################################################################################--
  4342.  
  4343. vrcOutdoorPtTable OBJECT-TYPE
  4344.  SYNTAX SEQUENCE OF VrcOutdoorPtEntry
  4345.  MAX-ACCESS  not-accessible
  4346.  STATUS current
  4347.  DESCRIPTION
  4348.   "Table that contains VRC outdoor status"
  4349.  ::= { vrc 16 }
  4350.  
  4351. vrcOutdoorPtEntry OBJECT-TYPE
  4352.  SYNTAX VrcOutdoorPtEntry
  4353.  MAX-ACCESS  not-accessible
  4354.  STATUS current
  4355.  DESCRIPTION
  4356.   "Entry in the vrcOutdoorPtTable: each entry represents data for a VRC
  4357.   outdoor"
  4358.  INDEX { vrcOutdoorPtIndex }
  4359.  ::= { vrcOutdoorPtTable 1 }
  4360.  
  4361. VrcOutdoorPtEntry ::= SEQUENCE {
  4362.  vrcOutdoorPtIndex    Integer32,
  4363.  vrcOutdoorPtName    SnmpAdminString,
  4364.  vrcOutdoorPtTemp    Integer32
  4365. }
  4366.  
  4367. vrcOutdoorPtIndex OBJECT-TYPE
  4368.  SYNTAX Integer32(1..100)
  4369.  MAX-ACCESS not-accessible
  4370.  STATUS current
  4371.  DESCRIPTION
  4372.   "Unique id for each entry in the table"
  4373.  ::= { vrcOutdoorPtEntry 1 }
  4374.  
  4375. vrcOutdoorPtName OBJECT-TYPE
  4376.  SYNTAX SnmpAdminString(SIZE (1..25))
  4377.  MAX-ACCESS read-only
  4378.  STATUS current
  4379.  DESCRIPTION
  4380.   "Outdoor name (factory-assigned)"
  4381.  ::= { vrcOutdoorPtEntry 2 }
  4382.  
  4383. vrcOutdoorPtTemp OBJECT-TYPE
  4384.  SYNTAX Integer32
  4385.  UNITS "decidegrees"
  4386.  MAX-ACCESS read-only
  4387.  STATUS current
  4388.  DESCRIPTION
  4389.   "Outdoor temperature value in tenths of a degree. Units are given by
  4390.   temperatureUnits field in deviceInfo. The range is determined by the
  4391.   current temperature units.
  4392.   Celsius:    -400 to 1000
  4393.   Fahrenheit: -400 to 2120"
  4394.  ::= { vrcOutdoorPtEntry 3 }
  4395.  
  4396. --###########################################################################################--
  4397. --vrcDischPtTable--
  4398. --###########################################################################################--
  4399.  
  4400. vrcDischPtTable OBJECT-TYPE
  4401.  SYNTAX SEQUENCE OF VrcDischPtEntry
  4402.  MAX-ACCESS  not-accessible
  4403.  STATUS current
  4404.  DESCRIPTION
  4405.   "Table that contains VRC discharge status"
  4406.  ::= { vrc 18 }
  4407.  
  4408. vrcDischPtEntry OBJECT-TYPE
  4409.  SYNTAX VrcDischPtEntry
  4410.  MAX-ACCESS  not-accessible
  4411.  STATUS current
  4412.  DESCRIPTION
  4413.   "Entry in the vrcDischPtTable: each entry represents discharge data for
  4414.   a VRC"
  4415.  INDEX { vrcDischPtIndex }
  4416.  ::= { vrcDischPtTable 1 }
  4417.  
  4418. VrcDischPtEntry ::= SEQUENCE {
  4419.  vrcDischPtIndex    Integer32,
  4420.  vrcDischPtName    SnmpAdminString,
  4421.  vrcDischPtTemp    Integer32,
  4422.  vrcDischPtPressure    Integer32,
  4423.  vrcDischPtHighTempAlarm    TruthValue,
  4424.  vrcDischPtHighTempFreqAlarm    TruthValue,
  4425.  vrcDischPtTempSensorFailAlarm    TruthValue
  4426. }
  4427.  
  4428. vrcDischPtIndex OBJECT-TYPE
  4429.  SYNTAX Integer32(1..100)
  4430.  MAX-ACCESS not-accessible
  4431.  STATUS current
  4432.  DESCRIPTION
  4433.   "Unique id for each entry in the table"
  4434.  ::= { vrcDischPtEntry 1 }
  4435.  
  4436. vrcDischPtName OBJECT-TYPE
  4437.  SYNTAX SnmpAdminString(SIZE (1..25))
  4438.  MAX-ACCESS read-only
  4439.  STATUS current
  4440.  DESCRIPTION
  4441.   "Discharge name (factory-assigned)"
  4442.  ::= { vrcDischPtEntry 2 }
  4443.  
  4444. vrcDischPtTemp OBJECT-TYPE
  4445.  SYNTAX Integer32
  4446.  UNITS "decidegrees"
  4447.  MAX-ACCESS read-write
  4448.  STATUS current
  4449.  DESCRIPTION
  4450.   "Discharge temperature value in tenths of a degree. Units are given by
  4451.   temperatureUnits field in deviceInfo. The range is determined by the
  4452.   current temperature units.
  4453.   Celsius:    -400 to 1560
  4454.   Fahrenheit: -400 to 3128"
  4455.  ::= { vrcDischPtEntry 3 }
  4456.  
  4457. vrcDischPtPressure OBJECT-TYPE
  4458.  SYNTAX Integer32(0..460)
  4459.  UNITS "decibars"
  4460.  MAX-ACCESS read-write
  4461.  STATUS current
  4462.  DESCRIPTION
  4463.   "Discharge air pressure value in tenths of a bar"
  4464.  ::= { vrcDischPtEntry 4 }
  4465.  
  4466. vrcDischPtHighTempAlarm OBJECT-TYPE
  4467.  SYNTAX TruthValue
  4468.  MAX-ACCESS read-only
  4469.  STATUS current
  4470.  DESCRIPTION
  4471.   "Discharge high temperature alarm state"
  4472.  ::= { vrcDischPtEntry 5 }
  4473.  
  4474. vrcDischPtHighTempFreqAlarm OBJECT-TYPE
  4475.  SYNTAX TruthValue
  4476.  MAX-ACCESS read-only
  4477.  STATUS current
  4478.  DESCRIPTION
  4479.   "Discharge high temperature frequently alarm state"
  4480.  ::= { vrcDischPtEntry 6 }
  4481.  
  4482. vrcDischPtTempSensorFailAlarm OBJECT-TYPE
  4483.  SYNTAX TruthValue
  4484.  MAX-ACCESS read-only
  4485.  STATUS current
  4486.  DESCRIPTION
  4487.   "Discharge temperature sensor failure alarm state"
  4488.  ::= { vrcDischPtEntry 7 }
  4489.  
  4490. --###########################################################################################--
  4491. --vrcDischCfgTable--
  4492. --###########################################################################################--
  4493.  
  4494. vrcDischCfgTable OBJECT-TYPE
  4495.  SYNTAX SEQUENCE OF VrcDischCfgEntry
  4496.  MAX-ACCESS  not-accessible
  4497.  STATUS current
  4498.  DESCRIPTION
  4499.   "Table used for VRC discharge configuration"
  4500.  ::= { vrc 19 }
  4501.  
  4502. vrcDischCfgEntry OBJECT-TYPE
  4503.  SYNTAX VrcDischCfgEntry
  4504.  MAX-ACCESS  not-accessible
  4505.  STATUS current
  4506.  DESCRIPTION
  4507.   "Entry in the vrcDischCfgTable: each entry contains config fields for
  4508.   VRC discharge"
  4509.  INDEX { vrcDischCfgIndex }
  4510.  ::= { vrcDischCfgTable 1 }
  4511.  
  4512. VrcDischCfgEntry ::= SEQUENCE {
  4513.  vrcDischCfgIndex    Integer32,
  4514.  vrcDischCfgTempCalValue    Integer32,
  4515.  vrcDischCfgPressCalValue    Integer32,
  4516.  vrcDischCfgHighTempAlmCtrl    INTEGER,
  4517.  vrcDischCfgHighTempFreqAlmCtrl    INTEGER,
  4518.  vrcDischCfgTempSensFailAlmCtrl    INTEGER
  4519. }
  4520.  
  4521. vrcDischCfgIndex OBJECT-TYPE
  4522.  SYNTAX Integer32(1..100)
  4523.  MAX-ACCESS not-accessible
  4524.  STATUS current
  4525.  DESCRIPTION
  4526.   "Unique id for each entry in the table"
  4527.  ::= { vrcDischCfgEntry 1 }
  4528.  
  4529. vrcDischCfgTempCalValue OBJECT-TYPE
  4530.  SYNTAX Integer32
  4531.  UNITS "decidegrees"
  4532.  MAX-ACCESS read-write
  4533.  STATUS current
  4534.  DESCRIPTION
  4535.   "Discharge temperature calibration value in tenths of a degree. Units
  4536.   are given by temperatureUnits field in deviceInfo. The settable range
  4537.   is determined by the current temperature units.
  4538.   Celsius:    -100 to 100
  4539.   Fahrenheit: -179 to 179"
  4540.  ::= { vrcDischCfgEntry 2 }
  4541.  
  4542. vrcDischCfgPressCalValue OBJECT-TYPE
  4543.  SYNTAX Integer32(-100..100)
  4544.  UNITS "decibars"
  4545.  MAX-ACCESS read-write
  4546.  STATUS current
  4547.  DESCRIPTION
  4548.   "Discharge pressure calibration value in tenths of a bar"
  4549.  ::= { vrcDischCfgEntry 3 }
  4550.  
  4551. vrcDischCfgHighTempAlmCtrl OBJECT-TYPE
  4552.  SYNTAX INTEGER {
  4553.    suspend(2),
  4554.    open(3)
  4555.    }
  4556.  MAX-ACCESS read-write
  4557.  STATUS current
  4558.  DESCRIPTION
  4559.   "Discharge high temperature alarm control:
  4560.   2 = suspend
  4561.   3 = open"
  4562.  ::= { vrcDischCfgEntry 4 }
  4563.  
  4564. vrcDischCfgHighTempFreqAlmCtrl OBJECT-TYPE
  4565.  SYNTAX INTEGER {
  4566.    suspend(2),
  4567.    open(3)
  4568.    }
  4569.  MAX-ACCESS read-write
  4570.  STATUS current
  4571.  DESCRIPTION
  4572.   "Discharge high temperature frequenctly alarm control:
  4573.   2 = suspend
  4574.   3 = open"
  4575.  ::= { vrcDischCfgEntry 5 }
  4576.  
  4577. vrcDischCfgTempSensFailAlmCtrl OBJECT-TYPE
  4578.  SYNTAX INTEGER {
  4579.    suspend(2),
  4580.    open(3)
  4581.    }
  4582.  MAX-ACCESS read-write
  4583.  STATUS current
  4584.  DESCRIPTION
  4585.   "Discharge temperature sensor failure alarm control:
  4586.   2 = suspend
  4587.   3 = open"
  4588.  ::= { vrcDischCfgEntry 6 }
  4589.  
  4590. --###########################################################################################--
  4591. --vrcSuctPtTable--
  4592. --###########################################################################################--
  4593.  
  4594. vrcSuctPtTable OBJECT-TYPE
  4595.  SYNTAX SEQUENCE OF VrcSuctPtEntry
  4596.  MAX-ACCESS  not-accessible
  4597.  STATUS current
  4598.  DESCRIPTION
  4599.   "Table that contains VRC suction status"
  4600.  ::= { vrc 20 }
  4601.  
  4602. vrcSuctPtEntry OBJECT-TYPE
  4603.  SYNTAX VrcSuctPtEntry
  4604.  MAX-ACCESS  not-accessible
  4605.  STATUS current
  4606.  DESCRIPTION
  4607.   "Entry in the vrcSuctPtTable: each entry represents suction data for a
  4608.   VRC"
  4609.  INDEX { vrcSuctPtIndex }
  4610.  ::= { vrcSuctPtTable 1 }
  4611.  
  4612. VrcSuctPtEntry ::= SEQUENCE {
  4613.  vrcSuctPtIndex    Integer32,
  4614.  vrcSuctPtName    SnmpAdminString,
  4615.  vrcSuctPtTemp    Integer32,
  4616.  vrcSuctPtPressure    Integer32,
  4617.  vrcSuctPtSuperHeatTemp    Integer32,
  4618.  vrcSuctPtTempSensorFailAlarm    TruthValue
  4619. }
  4620.  
  4621. vrcSuctPtIndex OBJECT-TYPE
  4622.  SYNTAX Integer32(1..100)
  4623.  MAX-ACCESS not-accessible
  4624.  STATUS current
  4625.  DESCRIPTION
  4626.   "Unique id for each entry in the table"
  4627.  ::= { vrcSuctPtEntry 1 }
  4628.  
  4629. vrcSuctPtName OBJECT-TYPE
  4630.  SYNTAX SnmpAdminString(SIZE (1..25))
  4631.  MAX-ACCESS read-only
  4632.  STATUS current
  4633.  DESCRIPTION
  4634.   "Suction name (factory-assigned)"
  4635.  ::= { vrcSuctPtEntry 2 }
  4636.  
  4637. vrcSuctPtTemp OBJECT-TYPE
  4638.  SYNTAX Integer32
  4639.  UNITS "decidegrees"
  4640.  MAX-ACCESS read-only
  4641.  STATUS current
  4642.  DESCRIPTION
  4643.   "Suction temperature in tenths of a degree. Units are given by
  4644.   temperatureUnits field in deviceInfo. The range is determined by the
  4645.   current temperature units.
  4646.   Celsius:    -400 to 1000
  4647.   Fahrenheit: -400 to 2120"
  4648.  ::= { vrcSuctPtEntry 3 }
  4649.  
  4650. vrcSuctPtPressure OBJECT-TYPE
  4651.  SYNTAX Integer32(0..173)
  4652.  UNITS "decibars"
  4653.  MAX-ACCESS read-only
  4654.  STATUS current
  4655.  DESCRIPTION
  4656.   "Suction air pressure in tenths of a bar"
  4657.  ::= { vrcSuctPtEntry 4 }
  4658.  
  4659. vrcSuctPtSuperHeatTemp OBJECT-TYPE
  4660.  SYNTAX Integer32
  4661.  UNITS "decidegrees"
  4662.  MAX-ACCESS read-only
  4663.  STATUS current
  4664.  DESCRIPTION
  4665.   "Suction super heat temperature in tenths of a degree. Units are given
  4666.   by temperatureUnits field in deviceInfo. The range is determined by
  4667.   the current temperature units.
  4668.   Celsius:    -400 to 1000
  4669.   Fahrenheit: -400 to 2120"
  4670.  ::= { vrcSuctPtEntry 5 }
  4671.  
  4672. vrcSuctPtTempSensorFailAlarm OBJECT-TYPE
  4673.  SYNTAX TruthValue
  4674.  MAX-ACCESS read-only
  4675.  STATUS current
  4676.  DESCRIPTION
  4677.   "Suction temperature sensor failure alarm state"
  4678.  ::= { vrcSuctPtEntry 6 }
  4679.  
  4680. --###########################################################################################--
  4681. --vrcSuctCfgTable--
  4682. --###########################################################################################--
  4683.  
  4684. vrcSuctCfgTable OBJECT-TYPE
  4685.  SYNTAX SEQUENCE OF VrcSuctCfgEntry
  4686.  MAX-ACCESS  not-accessible
  4687.  STATUS current
  4688.  DESCRIPTION
  4689.   "Table used for VRC suction configuration"
  4690.  ::= { vrc 21 }
  4691.  
  4692. vrcSuctCfgEntry OBJECT-TYPE
  4693.  SYNTAX VrcSuctCfgEntry
  4694.  MAX-ACCESS  not-accessible
  4695.  STATUS current
  4696.  DESCRIPTION
  4697.   "Entry in the vrcSuctCfgTable: each entry contains config fields for
  4698.   VRC suction"
  4699.  INDEX { vrcSuctCfgIndex }
  4700.  ::= { vrcSuctCfgTable 1 }
  4701.  
  4702. VrcSuctCfgEntry ::= SEQUENCE {
  4703.  vrcSuctCfgIndex    Integer32,
  4704.  vrcSuctCfgPressCalValue    Integer32,
  4705.  vrcSuctCfgTempSensFailAlmCtrl    INTEGER
  4706. }
  4707.  
  4708. vrcSuctCfgIndex OBJECT-TYPE
  4709.  SYNTAX Integer32(1..100)
  4710.  MAX-ACCESS not-accessible
  4711.  STATUS current
  4712.  DESCRIPTION
  4713.   "Unique id for each entry in the table"
  4714.  ::= { vrcSuctCfgEntry 1 }
  4715.  
  4716. vrcSuctCfgPressCalValue OBJECT-TYPE
  4717.  SYNTAX Integer32(-100..100)
  4718.  UNITS "decibars"
  4719.  MAX-ACCESS read-write
  4720.  STATUS current
  4721.  DESCRIPTION
  4722.   "Suction pressure calibration value in tenths of a bar"
  4723.  ::= { vrcSuctCfgEntry 2 }
  4724.  
  4725. vrcSuctCfgTempSensFailAlmCtrl OBJECT-TYPE
  4726.  SYNTAX INTEGER {
  4727.    suspend(2),
  4728.    open(3)
  4729.    }
  4730.  MAX-ACCESS read-write
  4731.  STATUS current
  4732.  DESCRIPTION
  4733.   "Suction temperature sensor failure alarm control:
  4734.   2 = suspend
  4735.   3 = open"
  4736.  ::= { vrcSuctCfgEntry 3 }
  4737.  
  4738. --###########################################################################################--
  4739. --Notifications--
  4740. --###########################################################################################--
  4741.  
  4742. trap OBJECT IDENTIFIER ::= { imd 32767 }
  4743.  
  4744. trapPrefix OBJECT IDENTIFIER ::= { trap 0 }
  4745.  
  4746. trapObj OBJECT IDENTIFIER ::= { trap 1 }
  4747.  
  4748.  
  4749. trapSeverity OBJECT-TYPE
  4750.  SYNTAX INTEGER {
  4751.    none(0),
  4752.    warning(1),
  4753.    alarm(2)
  4754.    }
  4755.  MAX-ACCESS accessible-for-notify
  4756.  STATUS current
  4757.  DESCRIPTION
  4758.   "Indicates the severity of the trap:
  4759.   0 = None
  4760.   1 = Warning
  4761.   2 = Alarm"
  4762.  ::= { trapObj 1 }
  4763.  
  4764. trapThreshType OBJECT-TYPE
  4765.  SYNTAX INTEGER {
  4766.    low(1),
  4767.    high(2)
  4768.    }
  4769.  MAX-ACCESS accessible-for-notify
  4770.  STATUS current
  4771.  DESCRIPTION
  4772.   "Only sent for threshold alarms. Identifies the threshold type:
  4773.   1 = Low
  4774.   2 = High"
  4775.  ::= { trapObj 2 }
  4776.  
  4777. internalTestNOTIFY NOTIFICATION-TYPE
  4778.  STATUS current
  4779.  DESCRIPTION "Test SNMP Trap"
  4780.  ::= { trapPrefix 10101 }
  4781.  
  4782. --#####deviceInfo#####--
  4783.  
  4784. --#####pdu#####--
  4785.  
  4786. --#####pduMainTable#####--
  4787.  
  4788. pduMainAvailNOTIFY NOTIFICATION-TYPE
  4789.  OBJECTS {
  4790.    pduMainAvail,
  4791.    trapSeverity,
  4792.    sysName,
  4793.    pduMainLabel
  4794.   }
  4795.  STATUS current
  4796.  DESCRIPTION "PDU availability trap"
  4797.  ::= { trapPrefix 10305 }
  4798.  
  4799. pduMainAvailCLEAR NOTIFICATION-TYPE
  4800.  OBJECTS {
  4801.    pduMainAvail,
  4802.    trapSeverity,
  4803.    sysName,
  4804.    pduMainLabel
  4805.   }
  4806.  STATUS current
  4807.  DESCRIPTION "PDU availability clear trap"
  4808.  ::= { trapPrefix 20305 }
  4809.  
  4810. pduTotalRealPowerNOTIFY NOTIFICATION-TYPE
  4811.  OBJECTS {
  4812.    pduTotalRealPower,
  4813.    trapThreshType,
  4814.    trapSeverity,
  4815.    sysName,
  4816.    pduMainLabel,
  4817.    pduTotalLabel
  4818.   }
  4819.  STATUS current
  4820.  DESCRIPTION "PDU total real power trap"
  4821.  ::= { trapPrefix 10309 }
  4822.  
  4823. pduTotalRealPowerCLEAR NOTIFICATION-TYPE
  4824.  OBJECTS {
  4825.    pduTotalRealPower,
  4826.    trapThreshType,
  4827.    trapSeverity,
  4828.    sysName,
  4829.    pduMainLabel,
  4830.    pduTotalLabel
  4831.   }
  4832.  STATUS current
  4833.  DESCRIPTION "PDU total real power clear trap"
  4834.  ::= { trapPrefix 20309 }
  4835.  
  4836. pduTotalApparentPowerNOTIFY NOTIFICATION-TYPE
  4837.  OBJECTS {
  4838.    pduTotalApparentPower,
  4839.    trapThreshType,
  4840.    trapSeverity,
  4841.    sysName,
  4842.    pduMainLabel,
  4843.    pduTotalLabel
  4844.   }
  4845.  STATUS current
  4846.  DESCRIPTION "PDU total apparent power trap"
  4847.  ::= { trapPrefix 10310 }
  4848.  
  4849. pduTotalApparentPowerCLEAR NOTIFICATION-TYPE
  4850.  OBJECTS {
  4851.    pduTotalApparentPower,
  4852.    trapThreshType,
  4853.    trapSeverity,
  4854.    sysName,
  4855.    pduMainLabel,
  4856.    pduTotalLabel
  4857.   }
  4858.  STATUS current
  4859.  DESCRIPTION "PDU total apparent power clear trap"
  4860.  ::= { trapPrefix 20310 }
  4861.  
  4862. pduTotalPowerFactorNOTIFY NOTIFICATION-TYPE
  4863.  OBJECTS {
  4864.    pduTotalPowerFactor,
  4865.    trapThreshType,
  4866.    trapSeverity,
  4867.    sysName,
  4868.    pduMainLabel,
  4869.    pduTotalLabel
  4870.   }
  4871.  STATUS current
  4872.  DESCRIPTION "PDU total power factor trap"
  4873.  ::= { trapPrefix 10311 }
  4874.  
  4875. pduTotalPowerFactorCLEAR NOTIFICATION-TYPE
  4876.  OBJECTS {
  4877.    pduTotalPowerFactor,
  4878.    trapThreshType,
  4879.    trapSeverity,
  4880.    sysName,
  4881.    pduMainLabel,
  4882.    pduTotalLabel
  4883.   }
  4884.  STATUS current
  4885.  DESCRIPTION "PDU total power factor clear trap"
  4886.  ::= { trapPrefix 20311 }
  4887.  
  4888. pduTotalEnergyNOTIFY NOTIFICATION-TYPE
  4889.  OBJECTS {
  4890.    pduTotalEnergy,
  4891.    trapThreshType,
  4892.    trapSeverity,
  4893.    sysName,
  4894.    pduMainLabel,
  4895.    pduTotalLabel
  4896.   }
  4897.  STATUS current
  4898.  DESCRIPTION "PDU total energy trap"
  4899.  ::= { trapPrefix 10312 }
  4900.  
  4901. pduTotalEnergyCLEAR NOTIFICATION-TYPE
  4902.  OBJECTS {
  4903.    pduTotalEnergy,
  4904.    trapThreshType,
  4905.    trapSeverity,
  4906.    sysName,
  4907.    pduMainLabel,
  4908.    pduTotalLabel
  4909.   }
  4910.  STATUS current
  4911.  DESCRIPTION "PDU total energy clear trap"
  4912.  ::= { trapPrefix 20312 }
  4913.  
  4914. --#####pduPhaseTable#####--
  4915.  
  4916. pduPhaseVoltageNOTIFY NOTIFICATION-TYPE
  4917.  OBJECTS {
  4918.    pduPhaseVoltage,
  4919.    trapThreshType,
  4920.    trapSeverity,
  4921.    sysName,
  4922.    pduMainLabel,
  4923.    pduPhaseLabel
  4924.   }
  4925.  STATUS current
  4926.  DESCRIPTION "PDU phase voltage trap"
  4927.  ::= { trapPrefix 10324 }
  4928.  
  4929. pduPhaseVoltageCLEAR NOTIFICATION-TYPE
  4930.  OBJECTS {
  4931.    pduPhaseVoltage,
  4932.    trapThreshType,
  4933.    trapSeverity,
  4934.    sysName,
  4935.    pduMainLabel,
  4936.    pduPhaseLabel
  4937.   }
  4938.  STATUS current
  4939.  DESCRIPTION "PDU phase voltage clear trap"
  4940.  ::= { trapPrefix 20324 }
  4941.  
  4942. pduPhaseCurrentNOTIFY NOTIFICATION-TYPE
  4943.  OBJECTS {
  4944.    pduPhaseCurrent,
  4945.    trapThreshType,
  4946.    trapSeverity,
  4947.    sysName,
  4948.    pduMainLabel,
  4949.    pduPhaseLabel
  4950.   }
  4951.  STATUS current
  4952.  DESCRIPTION "PDU phase current trap"
  4953.  ::= { trapPrefix 10328 }
  4954.  
  4955. pduPhaseCurrentCLEAR NOTIFICATION-TYPE
  4956.  OBJECTS {
  4957.    pduPhaseCurrent,
  4958.    trapThreshType,
  4959.    trapSeverity,
  4960.    sysName,
  4961.    pduMainLabel,
  4962.    pduPhaseLabel
  4963.   }
  4964.  STATUS current
  4965.  DESCRIPTION "PDU phase current clear trap"
  4966.  ::= { trapPrefix 20328 }
  4967.  
  4968. pduPhaseRealPowerNOTIFY NOTIFICATION-TYPE
  4969.  OBJECTS {
  4970.    pduPhaseRealPower,
  4971.    trapThreshType,
  4972.    trapSeverity,
  4973.    sysName,
  4974.    pduMainLabel,
  4975.    pduPhaseLabel
  4976.   }
  4977.  STATUS current
  4978.  DESCRIPTION "PDU phase real power trap"
  4979.  ::= { trapPrefix 10332 }
  4980.  
  4981. pduPhaseRealPowerCLEAR NOTIFICATION-TYPE
  4982.  OBJECTS {
  4983.    pduPhaseRealPower,
  4984.    trapThreshType,
  4985.    trapSeverity,
  4986.    sysName,
  4987.    pduMainLabel,
  4988.    pduPhaseLabel
  4989.   }
  4990.  STATUS current
  4991.  DESCRIPTION "PDU phase real power clear trap"
  4992.  ::= { trapPrefix 20332 }
  4993.  
  4994. pduPhaseApparentPowerNOTIFY NOTIFICATION-TYPE
  4995.  OBJECTS {
  4996.    pduPhaseApparentPower,
  4997.    trapThreshType,
  4998.    trapSeverity,
  4999.    sysName,
  5000.    pduMainLabel,
  5001.    pduPhaseLabel
  5002.   }
  5003.  STATUS current
  5004.  DESCRIPTION "PDU phase apparent power trap"
  5005.  ::= { trapPrefix 10333 }
  5006.  
  5007. pduPhaseApparentPowerCLEAR NOTIFICATION-TYPE
  5008.  OBJECTS {
  5009.    pduPhaseApparentPower,
  5010.    trapThreshType,
  5011.    trapSeverity,
  5012.    sysName,
  5013.    pduMainLabel,
  5014.    pduPhaseLabel
  5015.   }
  5016.  STATUS current
  5017.  DESCRIPTION "PDU phase apparent power clear trap"
  5018.  ::= { trapPrefix 20333 }
  5019.  
  5020. pduPhasePowerFactorNOTIFY NOTIFICATION-TYPE
  5021.  OBJECTS {
  5022.    pduPhasePowerFactor,
  5023.    trapThreshType,
  5024.    trapSeverity,
  5025.    sysName,
  5026.    pduMainLabel,
  5027.    pduPhaseLabel
  5028.   }
  5029.  STATUS current
  5030.  DESCRIPTION "PDU phase power factor trap"
  5031.  ::= { trapPrefix 10334 }
  5032.  
  5033. pduPhasePowerFactorCLEAR NOTIFICATION-TYPE
  5034.  OBJECTS {
  5035.    pduPhasePowerFactor,
  5036.    trapThreshType,
  5037.    trapSeverity,
  5038.    sysName,
  5039.    pduMainLabel,
  5040.    pduPhaseLabel
  5041.   }
  5042.  STATUS current
  5043.  DESCRIPTION "PDU phase power factor clear trap"
  5044.  ::= { trapPrefix 20334 }
  5045.  
  5046. pduPhaseEnergyNOTIFY NOTIFICATION-TYPE
  5047.  OBJECTS {
  5048.    pduPhaseEnergy,
  5049.    trapThreshType,
  5050.    trapSeverity,
  5051.    sysName,
  5052.    pduMainLabel,
  5053.    pduPhaseLabel
  5054.   }
  5055.  STATUS current
  5056.  DESCRIPTION "PDU phase energy trap"
  5057.  ::= { trapPrefix 10335 }
  5058.  
  5059. pduPhaseEnergyCLEAR NOTIFICATION-TYPE
  5060.  OBJECTS {
  5061.    pduPhaseEnergy,
  5062.    trapThreshType,
  5063.    trapSeverity,
  5064.    sysName,
  5065.    pduMainLabel,
  5066.    pduPhaseLabel
  5067.   }
  5068.  STATUS current
  5069.  DESCRIPTION "PDU phase energy clear trap"
  5070.  ::= { trapPrefix 20335 }
  5071.  
  5072. pduPhaseBalanceNOTIFY NOTIFICATION-TYPE
  5073.  OBJECTS {
  5074.    pduPhaseBalance,
  5075.    trapThreshType,
  5076.    trapSeverity,
  5077.    sysName,
  5078.    pduMainLabel,
  5079.    pduPhaseLabel
  5080.   }
  5081.  STATUS current
  5082.  DESCRIPTION "PDU phase balance trap"
  5083.  ::= { trapPrefix 10337 }
  5084.  
  5085. pduPhaseBalanceCLEAR NOTIFICATION-TYPE
  5086.  OBJECTS {
  5087.    pduPhaseBalance,
  5088.    trapThreshType,
  5089.    trapSeverity,
  5090.    sysName,
  5091.    pduMainLabel,
  5092.    pduPhaseLabel
  5093.   }
  5094.  STATUS current
  5095.  DESCRIPTION "PDU phase balance clear trap"
  5096.  ::= { trapPrefix 20337 }
  5097.  
  5098. pduPhaseCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
  5099.  OBJECTS {
  5100.    pduPhaseCurrentCrestFactor,
  5101.    trapThreshType,
  5102.    trapSeverity,
  5103.    sysName,
  5104.    pduMainLabel,
  5105.    pduPhaseLabel
  5106.   }
  5107.  STATUS current
  5108.  DESCRIPTION "PDU phase current crest factor trap"
  5109.  ::= { trapPrefix 10339 }
  5110.  
  5111. pduPhaseCurrentCrestFactorCLEAR NOTIFICATION-TYPE
  5112.  OBJECTS {
  5113.    pduPhaseCurrentCrestFactor,
  5114.    trapThreshType,
  5115.    trapSeverity,
  5116.    sysName,
  5117.    pduMainLabel,
  5118.    pduPhaseLabel
  5119.   }
  5120.  STATUS current
  5121.  DESCRIPTION "PDU phase current crest factor clear trap"
  5122.  ::= { trapPrefix 20339 }
  5123.  
  5124. --#####pduBreakerTable#####--
  5125.  
  5126. pduBreakerCurrentNOTIFY NOTIFICATION-TYPE
  5127.  OBJECTS {
  5128.    pduBreakerCurrent,
  5129.    trapThreshType,
  5130.    trapSeverity,
  5131.    sysName,
  5132.    pduMainLabel,
  5133.    pduBreakerLabel
  5134.   }
  5135.  STATUS current
  5136.  DESCRIPTION "PDU breaker current trap"
  5137.  ::= { trapPrefix 10354 }
  5138.  
  5139. pduBreakerCurrentCLEAR NOTIFICATION-TYPE
  5140.  OBJECTS {
  5141.    pduBreakerCurrent,
  5142.    trapThreshType,
  5143.    trapSeverity,
  5144.    sysName,
  5145.    pduMainLabel,
  5146.    pduBreakerLabel
  5147.   }
  5148.  STATUS current
  5149.  DESCRIPTION "PDU breaker current clear trap"
  5150.  ::= { trapPrefix 20354 }
  5151.  
  5152. pduBreakerVoltageNOTIFY NOTIFICATION-TYPE
  5153.  OBJECTS {
  5154.    pduBreakerVoltage,
  5155.    trapThreshType,
  5156.    trapSeverity,
  5157.    sysName,
  5158.    pduMainLabel,
  5159.    pduBreakerLabel
  5160.   }
  5161.  STATUS current
  5162.  DESCRIPTION "PDU breaker voltage trap"
  5163.  ::= { trapPrefix 10358 }
  5164.  
  5165. pduBreakerVoltageCLEAR NOTIFICATION-TYPE
  5166.  OBJECTS {
  5167.    pduBreakerVoltage,
  5168.    trapThreshType,
  5169.    trapSeverity,
  5170.    sysName,
  5171.    pduMainLabel,
  5172.    pduBreakerLabel
  5173.   }
  5174.  STATUS current
  5175.  DESCRIPTION "PDU breaker voltage clear trap"
  5176.  ::= { trapPrefix 20358 }
  5177.  
  5178. pduBreakerRealPowerNOTIFY NOTIFICATION-TYPE
  5179.  OBJECTS {
  5180.    pduBreakerRealPower,
  5181.    trapThreshType,
  5182.    trapSeverity,
  5183.    sysName,
  5184.    pduMainLabel,
  5185.    pduBreakerLabel
  5186.   }
  5187.  STATUS current
  5188.  DESCRIPTION "PDU breaker real power trap"
  5189.  ::= { trapPrefix 10362 }
  5190.  
  5191. pduBreakerRealPowerCLEAR NOTIFICATION-TYPE
  5192.  OBJECTS {
  5193.    pduBreakerRealPower,
  5194.    trapThreshType,
  5195.    trapSeverity,
  5196.    sysName,
  5197.    pduMainLabel,
  5198.    pduBreakerLabel
  5199.   }
  5200.  STATUS current
  5201.  DESCRIPTION "PDU breaker real power clear trap"
  5202.  ::= { trapPrefix 20362 }
  5203.  
  5204. pduBreakerApparentPowerNOTIFY NOTIFICATION-TYPE
  5205.  OBJECTS {
  5206.    pduBreakerApparentPower,
  5207.    trapThreshType,
  5208.    trapSeverity,
  5209.    sysName,
  5210.    pduMainLabel,
  5211.    pduBreakerLabel
  5212.   }
  5213.  STATUS current
  5214.  DESCRIPTION "PDU breaker apparent power trap"
  5215.  ::= { trapPrefix 10363 }
  5216.  
  5217. pduBreakerApparentPowerCLEAR NOTIFICATION-TYPE
  5218.  OBJECTS {
  5219.    pduBreakerApparentPower,
  5220.    trapThreshType,
  5221.    trapSeverity,
  5222.    sysName,
  5223.    pduMainLabel,
  5224.    pduBreakerLabel
  5225.   }
  5226.  STATUS current
  5227.  DESCRIPTION "PDU breaker apparent power clear trap"
  5228.  ::= { trapPrefix 20363 }
  5229.  
  5230. pduBreakerPowerFactorNOTIFY NOTIFICATION-TYPE
  5231.  OBJECTS {
  5232.    pduBreakerPowerFactor,
  5233.    trapThreshType,
  5234.    trapSeverity,
  5235.    sysName,
  5236.    pduMainLabel,
  5237.    pduBreakerLabel
  5238.   }
  5239.  STATUS current
  5240.  DESCRIPTION "PDU breaker power factor trap"
  5241.  ::= { trapPrefix 10364 }
  5242.  
  5243. pduBreakerPowerFactorCLEAR NOTIFICATION-TYPE
  5244.  OBJECTS {
  5245.    pduBreakerPowerFactor,
  5246.    trapThreshType,
  5247.    trapSeverity,
  5248.    sysName,
  5249.    pduMainLabel,
  5250.    pduBreakerLabel
  5251.   }
  5252.  STATUS current
  5253.  DESCRIPTION "PDU breaker power factor clear trap"
  5254.  ::= { trapPrefix 20364 }
  5255.  
  5256. pduBreakerEnergyNOTIFY NOTIFICATION-TYPE
  5257.  OBJECTS {
  5258.    pduBreakerEnergy,
  5259.    trapThreshType,
  5260.    trapSeverity,
  5261.    sysName,
  5262.    pduMainLabel,
  5263.    pduBreakerLabel
  5264.   }
  5265.  STATUS current
  5266.  DESCRIPTION "PDU breaker energy trap"
  5267.  ::= { trapPrefix 10365 }
  5268.  
  5269. pduBreakerEnergyCLEAR NOTIFICATION-TYPE
  5270.  OBJECTS {
  5271.    pduBreakerEnergy,
  5272.    trapThreshType,
  5273.    trapSeverity,
  5274.    sysName,
  5275.    pduMainLabel,
  5276.    pduBreakerLabel
  5277.   }
  5278.  STATUS current
  5279.  DESCRIPTION "PDU breaker energy clear trap"
  5280.  ::= { trapPrefix 20365 }
  5281.  
  5282. --#####pduLineTable#####--
  5283.  
  5284. pduLineCurrentNOTIFY NOTIFICATION-TYPE
  5285.  OBJECTS {
  5286.    pduLineCurrent,
  5287.    trapThreshType,
  5288.    trapSeverity,
  5289.    sysName,
  5290.    pduMainLabel,
  5291.    pduLineLabel
  5292.   }
  5293.  STATUS current
  5294.  DESCRIPTION "PDU line current trap"
  5295.  ::= { trapPrefix 10374 }
  5296.  
  5297. pduLineCurrentCLEAR NOTIFICATION-TYPE
  5298.  OBJECTS {
  5299.    pduLineCurrent,
  5300.    trapThreshType,
  5301.    trapSeverity,
  5302.    sysName,
  5303.    pduMainLabel,
  5304.    pduLineLabel
  5305.   }
  5306.  STATUS current
  5307.  DESCRIPTION "PDU line current clear trap"
  5308.  ::= { trapPrefix 20374 }
  5309.  
  5310. --#####pduOutletSwitchTable#####--
  5311.  
  5312. --#####pduOutletMeterTable#####--
  5313.  
  5314. pduOutletMeterVoltageNOTIFY NOTIFICATION-TYPE
  5315.  OBJECTS {
  5316.    pduOutletMeterVoltage,
  5317.    trapThreshType,
  5318.    trapSeverity,
  5319.    sysName,
  5320.    pduMainLabel,
  5321.    pduOutletMeterLabel
  5322.   }
  5323.  STATUS current
  5324.  DESCRIPTION "PDU outlet voltage trap"
  5325.  ::= { trapPrefix 10385 }
  5326.  
  5327. pduOutletMeterVoltageCLEAR NOTIFICATION-TYPE
  5328.  OBJECTS {
  5329.    pduOutletMeterVoltage,
  5330.    trapThreshType,
  5331.    trapSeverity,
  5332.    sysName,
  5333.    pduMainLabel,
  5334.    pduOutletMeterLabel
  5335.   }
  5336.  STATUS current
  5337.  DESCRIPTION "PDU outlet voltage clear trap"
  5338.  ::= { trapPrefix 20385 }
  5339.  
  5340. pduOutletMeterCurrentNOTIFY NOTIFICATION-TYPE
  5341.  OBJECTS {
  5342.    pduOutletMeterCurrent,
  5343.    trapThreshType,
  5344.    trapSeverity,
  5345.    sysName,
  5346.    pduMainLabel,
  5347.    pduOutletMeterLabel
  5348.   }
  5349.  STATUS current
  5350.  DESCRIPTION "PDU outlet current trap"
  5351.  ::= { trapPrefix 10389 }
  5352.  
  5353. pduOutletMeterCurrentCLEAR NOTIFICATION-TYPE
  5354.  OBJECTS {
  5355.    pduOutletMeterCurrent,
  5356.    trapThreshType,
  5357.    trapSeverity,
  5358.    sysName,
  5359.    pduMainLabel,
  5360.    pduOutletMeterLabel
  5361.   }
  5362.  STATUS current
  5363.  DESCRIPTION "PDU outlet current clear trap"
  5364.  ::= { trapPrefix 20389 }
  5365.  
  5366. pduOutletMeterRealPowerNOTIFY NOTIFICATION-TYPE
  5367.  OBJECTS {
  5368.    pduOutletMeterRealPower,
  5369.    trapThreshType,
  5370.    trapSeverity,
  5371.    sysName,
  5372.    pduMainLabel,
  5373.    pduOutletMeterLabel
  5374.   }
  5375.  STATUS current
  5376.  DESCRIPTION "PDU outlet real power trap"
  5377.  ::= { trapPrefix 10393 }
  5378.  
  5379. pduOutletMeterRealPowerCLEAR NOTIFICATION-TYPE
  5380.  OBJECTS {
  5381.    pduOutletMeterRealPower,
  5382.    trapThreshType,
  5383.    trapSeverity,
  5384.    sysName,
  5385.    pduMainLabel,
  5386.    pduOutletMeterLabel
  5387.   }
  5388.  STATUS current
  5389.  DESCRIPTION "PDU outlet real power clear trap"
  5390.  ::= { trapPrefix 20393 }
  5391.  
  5392. pduOutletMeterApparentPowerNOTIFY NOTIFICATION-TYPE
  5393.  OBJECTS {
  5394.    pduOutletMeterApparentPower,
  5395.    trapThreshType,
  5396.    trapSeverity,
  5397.    sysName,
  5398.    pduMainLabel,
  5399.    pduOutletMeterLabel
  5400.   }
  5401.  STATUS current
  5402.  DESCRIPTION "PDU outlet apparent power trap"
  5403.  ::= { trapPrefix 10394 }
  5404.  
  5405. pduOutletMeterApparentPowerCLEAR NOTIFICATION-TYPE
  5406.  OBJECTS {
  5407.    pduOutletMeterApparentPower,
  5408.    trapThreshType,
  5409.    trapSeverity,
  5410.    sysName,
  5411.    pduMainLabel,
  5412.    pduOutletMeterLabel
  5413.   }
  5414.  STATUS current
  5415.  DESCRIPTION "PDU outlet apparent power clear trap"
  5416.  ::= { trapPrefix 20394 }
  5417.  
  5418. pduOutletMeterPowerFactorNOTIFY NOTIFICATION-TYPE
  5419.  OBJECTS {
  5420.    pduOutletMeterPowerFactor,
  5421.    trapThreshType,
  5422.    trapSeverity,
  5423.    sysName,
  5424.    pduMainLabel,
  5425.    pduOutletMeterLabel
  5426.   }
  5427.  STATUS current
  5428.  DESCRIPTION "PDU outlet power factor trap"
  5429.  ::= { trapPrefix 10395 }
  5430.  
  5431. pduOutletMeterPowerFactorCLEAR NOTIFICATION-TYPE
  5432.  OBJECTS {
  5433.    pduOutletMeterPowerFactor,
  5434.    trapThreshType,
  5435.    trapSeverity,
  5436.    sysName,
  5437.    pduMainLabel,
  5438.    pduOutletMeterLabel
  5439.   }
  5440.  STATUS current
  5441.  DESCRIPTION "PDU outlet power factor clear trap"
  5442.  ::= { trapPrefix 20395 }
  5443.  
  5444. pduOutletMeterEnergyNOTIFY NOTIFICATION-TYPE
  5445.  OBJECTS {
  5446.    pduOutletMeterEnergy,
  5447.    trapThreshType,
  5448.    trapSeverity,
  5449.    sysName,
  5450.    pduMainLabel,
  5451.    pduOutletMeterLabel
  5452.   }
  5453.  STATUS current
  5454.  DESCRIPTION "PDU outlet energy trap"
  5455.  ::= { trapPrefix 10396 }
  5456.  
  5457. pduOutletMeterEnergyCLEAR NOTIFICATION-TYPE
  5458.  OBJECTS {
  5459.    pduOutletMeterEnergy,
  5460.    trapThreshType,
  5461.    trapSeverity,
  5462.    sysName,
  5463.    pduMainLabel,
  5464.    pduOutletMeterLabel
  5465.   }
  5466.  STATUS current
  5467.  DESCRIPTION "PDU outlet energy clear trap"
  5468.  ::= { trapPrefix 20396 }
  5469.  
  5470. pduOutletCurrentCrestFactorNOTIFY NOTIFICATION-TYPE
  5471.  OBJECTS {
  5472.    pduOutletCurrentCrestFactor,
  5473.    trapThreshType,
  5474.    trapSeverity,
  5475.    sysName,
  5476.    pduMainLabel,
  5477.    pduOutletMeterLabel
  5478.   }
  5479.  STATUS current
  5480.  DESCRIPTION "PDU outlet current crest factor trap"
  5481.  ::= { trapPrefix 10400 }
  5482.  
  5483. pduOutletCurrentCrestFactorCLEAR NOTIFICATION-TYPE
  5484.  OBJECTS {
  5485.    pduOutletCurrentCrestFactor,
  5486.    trapThreshType,
  5487.    trapSeverity,
  5488.    sysName,
  5489.    pduMainLabel,
  5490.    pduOutletMeterLabel
  5491.   }
  5492.  STATUS current
  5493.  DESCRIPTION "PDU outlet current crest factor clear trap"
  5494.  ::= { trapPrefix 20400 }
  5495.  
  5496. --#####tempSensorTable#####--
  5497.  
  5498. tempSensorAvailNOTIFY NOTIFICATION-TYPE
  5499.  OBJECTS {
  5500.    tempSensorAvail,
  5501.    trapSeverity,
  5502.    sysName,
  5503.    tempSensorLabel
  5504.   }
  5505.  STATUS current
  5506.  DESCRIPTION "RT availability trap"
  5507.  ::= { trapPrefix 10404 }
  5508.  
  5509. tempSensorAvailCLEAR NOTIFICATION-TYPE
  5510.  OBJECTS {
  5511.    tempSensorAvail,
  5512.    trapSeverity,
  5513.    sysName,
  5514.    tempSensorLabel
  5515.   }
  5516.  STATUS current
  5517.  DESCRIPTION "RT availability clear trap"
  5518.  ::= { trapPrefix 20404 }
  5519.  
  5520. tempSensorTempNOTIFY NOTIFICATION-TYPE
  5521.  OBJECTS {
  5522.    tempSensorTemp,
  5523.    temperatureUnits,
  5524.    trapThreshType,
  5525.    trapSeverity,
  5526.    sysName,
  5527.    tempSensorLabel
  5528.   }
  5529.  STATUS current
  5530.  DESCRIPTION "RT temperature trap"
  5531.  ::= { trapPrefix 10405 }
  5532.  
  5533. tempSensorTempCLEAR NOTIFICATION-TYPE
  5534.  OBJECTS {
  5535.    tempSensorTemp,
  5536.    temperatureUnits,
  5537.    trapThreshType,
  5538.    trapSeverity,
  5539.    sysName,
  5540.    tempSensorLabel
  5541.   }
  5542.  STATUS current
  5543.  DESCRIPTION "RT temperature clear trap"
  5544.  ::= { trapPrefix 20405 }
  5545.  
  5546. --#####airFlowSensorTable#####--
  5547.  
  5548. airFlowSensorAvailNOTIFY NOTIFICATION-TYPE
  5549.  OBJECTS {
  5550.    airFlowSensorAvail,
  5551.    trapSeverity,
  5552.    sysName,
  5553.    airFlowSensorLabel
  5554.   }
  5555.  STATUS current
  5556.  DESCRIPTION "AFHT3 availability trap"
  5557.  ::= { trapPrefix 10504 }
  5558.  
  5559. airFlowSensorAvailCLEAR NOTIFICATION-TYPE
  5560.  OBJECTS {
  5561.    airFlowSensorAvail,
  5562.    trapSeverity,
  5563.    sysName,
  5564.    airFlowSensorLabel
  5565.   }
  5566.  STATUS current
  5567.  DESCRIPTION "AFHT3 availability clear trap"
  5568.  ::= { trapPrefix 20504 }
  5569.  
  5570. airFlowSensorTempNOTIFY NOTIFICATION-TYPE
  5571.  OBJECTS {
  5572.    airFlowSensorTemp,
  5573.    temperatureUnits,
  5574.    trapThreshType,
  5575.    trapSeverity,
  5576.    sysName,
  5577.    airFlowSensorLabel
  5578.   }
  5579.  STATUS current
  5580.  DESCRIPTION "AFHT3 temperature trap"
  5581.  ::= { trapPrefix 10505 }
  5582.  
  5583. airFlowSensorTempCLEAR NOTIFICATION-TYPE
  5584.  OBJECTS {
  5585.    airFlowSensorTemp,
  5586.    temperatureUnits,
  5587.    trapThreshType,
  5588.    trapSeverity,
  5589.    sysName,
  5590.    airFlowSensorLabel
  5591.   }
  5592.  STATUS current
  5593.  DESCRIPTION "AFHT3 temperature clear trap"
  5594.  ::= { trapPrefix 20505 }
  5595.  
  5596. airFlowSensorFlowNOTIFY NOTIFICATION-TYPE
  5597.  OBJECTS {
  5598.    airFlowSensorFlow,
  5599.    trapThreshType,
  5600.    trapSeverity,
  5601.    sysName,
  5602.    airFlowSensorLabel
  5603.   }
  5604.  STATUS current
  5605.  DESCRIPTION "AFHT3 airflow trap"
  5606.  ::= { trapPrefix 10506 }
  5607.  
  5608. airFlowSensorFlowCLEAR NOTIFICATION-TYPE
  5609.  OBJECTS {
  5610.    airFlowSensorFlow,
  5611.    trapThreshType,
  5612.    trapSeverity,
  5613.    sysName,
  5614.    airFlowSensorLabel
  5615.   }
  5616.  STATUS current
  5617.  DESCRIPTION "AFHT3 airflow clear trap"
  5618.  ::= { trapPrefix 20506 }
  5619.  
  5620. airFlowSensorHumidityNOTIFY NOTIFICATION-TYPE
  5621.  OBJECTS {
  5622.    airFlowSensorHumidity,
  5623.    trapThreshType,
  5624.    trapSeverity,
  5625.    sysName,
  5626.    airFlowSensorLabel
  5627.   }
  5628.  STATUS current
  5629.  DESCRIPTION "AFHT3 humidity trap"
  5630.  ::= { trapPrefix 10507 }
  5631.  
  5632. airFlowSensorHumidityCLEAR NOTIFICATION-TYPE
  5633.  OBJECTS {
  5634.    airFlowSensorHumidity,
  5635.    trapThreshType,
  5636.    trapSeverity,
  5637.    sysName,
  5638.    airFlowSensorLabel
  5639.   }
  5640.  STATUS current
  5641.  DESCRIPTION "AFHT3 humidity clear trap"
  5642.  ::= { trapPrefix 20507 }
  5643.  
  5644. airFlowSensorDewPointNOTIFY NOTIFICATION-TYPE
  5645.  OBJECTS {
  5646.    airFlowSensorDewPoint,
  5647.    temperatureUnits,
  5648.    trapThreshType,
  5649.    trapSeverity,
  5650.    sysName,
  5651.    airFlowSensorLabel
  5652.   }
  5653.  STATUS current
  5654.  DESCRIPTION "AFHT3 dewpoint trap"
  5655.  ::= { trapPrefix 10508 }
  5656.  
  5657. airFlowSensorDewPointCLEAR NOTIFICATION-TYPE
  5658.  OBJECTS {
  5659.    airFlowSensorDewPoint,
  5660.    temperatureUnits,
  5661.    trapThreshType,
  5662.    trapSeverity,
  5663.    sysName,
  5664.    airFlowSensorLabel
  5665.   }
  5666.  STATUS current
  5667.  DESCRIPTION "AFHT3 dewpoint clear trap"
  5668.  ::= { trapPrefix 20508 }
  5669.  
  5670. --#####t3hdSensorTable#####--
  5671.  
  5672. t3hdSensorAvailNOTIFY NOTIFICATION-TYPE
  5673.  OBJECTS {
  5674.    t3hdSensorAvail,
  5675.    trapSeverity,
  5676.    sysName,
  5677.    t3hdSensorLabel
  5678.   }
  5679.  STATUS current
  5680.  DESCRIPTION "T3HD availability trap"
  5681.  ::= { trapPrefix 10804 }
  5682.  
  5683. t3hdSensorAvailCLEAR NOTIFICATION-TYPE
  5684.  OBJECTS {
  5685.    t3hdSensorAvail,
  5686.    trapSeverity,
  5687.    sysName,
  5688.    t3hdSensorLabel
  5689.   }
  5690.  STATUS current
  5691.  DESCRIPTION "T3HD availability clear trap"
  5692.  ::= { trapPrefix 20804 }
  5693.  
  5694. t3hdSensorIntTempNOTIFY NOTIFICATION-TYPE
  5695.  OBJECTS {
  5696.    t3hdSensorIntTemp,
  5697.    temperatureUnits,
  5698.    trapThreshType,
  5699.    trapSeverity,
  5700.    sysName,
  5701.    t3hdSensorLabel,
  5702.    t3hdSensorIntLabel
  5703.   }
  5704.  STATUS current
  5705.  DESCRIPTION "T3HD Internal temperature trap"
  5706.  ::= { trapPrefix 10806 }
  5707.  
  5708. t3hdSensorIntTempCLEAR NOTIFICATION-TYPE
  5709.  OBJECTS {
  5710.    t3hdSensorIntTemp,
  5711.    temperatureUnits,
  5712.    trapThreshType,
  5713.    trapSeverity,
  5714.    sysName,
  5715.    t3hdSensorLabel,
  5716.    t3hdSensorIntLabel
  5717.   }
  5718.  STATUS current
  5719.  DESCRIPTION "T3HD Internal temperature clear trap"
  5720.  ::= { trapPrefix 20806 }
  5721.  
  5722. t3hdSensorIntHumidityNOTIFY NOTIFICATION-TYPE
  5723.  OBJECTS {
  5724.    t3hdSensorIntHumidity,
  5725.    trapThreshType,
  5726.    trapSeverity,
  5727.    sysName,
  5728.    t3hdSensorLabel,
  5729.    t3hdSensorIntLabel
  5730.   }
  5731.  STATUS current
  5732.  DESCRIPTION "T3HD Internal humidity trap"
  5733.  ::= { trapPrefix 10807 }
  5734.  
  5735. t3hdSensorIntHumidityCLEAR NOTIFICATION-TYPE
  5736.  OBJECTS {
  5737.    t3hdSensorIntHumidity,
  5738.    trapThreshType,
  5739.    trapSeverity,
  5740.    sysName,
  5741.    t3hdSensorLabel,
  5742.    t3hdSensorIntLabel
  5743.   }
  5744.  STATUS current
  5745.  DESCRIPTION "T3HD Internal humidity clear trap"
  5746.  ::= { trapPrefix 20807 }
  5747.  
  5748. t3hdSensorIntDewPointNOTIFY NOTIFICATION-TYPE
  5749.  OBJECTS {
  5750.    t3hdSensorIntDewPoint,
  5751.    temperatureUnits,
  5752.    trapThreshType,
  5753.    trapSeverity,
  5754.    sysName,
  5755.    t3hdSensorLabel,
  5756.    t3hdSensorIntLabel
  5757.   }
  5758.  STATUS current
  5759.  DESCRIPTION "T3HD Internal dewpoint trap"
  5760.  ::= { trapPrefix 10808 }
  5761.  
  5762. t3hdSensorIntDewPointCLEAR NOTIFICATION-TYPE
  5763.  OBJECTS {
  5764.    t3hdSensorIntDewPoint,
  5765.    temperatureUnits,
  5766.    trapThreshType,
  5767.    trapSeverity,
  5768.    sysName,
  5769.    t3hdSensorLabel,
  5770.    t3hdSensorIntLabel
  5771.   }
  5772.  STATUS current
  5773.  DESCRIPTION "T3HD Internal dewpoint clear trap"
  5774.  ::= { trapPrefix 20808 }
  5775.  
  5776. t3hdSensorExtATempNOTIFY NOTIFICATION-TYPE
  5777.  OBJECTS {
  5778.    t3hdSensorExtATemp,
  5779.    temperatureUnits,
  5780.    trapThreshType,
  5781.    trapSeverity,
  5782.    sysName,
  5783.    t3hdSensorLabel,
  5784.    t3hdSensorExtALabel
  5785.   }
  5786.  STATUS current
  5787.  DESCRIPTION "T3HD External A temperature trap"
  5788.  ::= { trapPrefix 10811 }
  5789.  
  5790. t3hdSensorExtATempCLEAR NOTIFICATION-TYPE
  5791.  OBJECTS {
  5792.    t3hdSensorExtATemp,
  5793.    temperatureUnits,
  5794.    trapThreshType,
  5795.    trapSeverity,
  5796.    sysName,
  5797.    t3hdSensorLabel,
  5798.    t3hdSensorExtALabel
  5799.   }
  5800.  STATUS current
  5801.  DESCRIPTION "T3HD External A temperature clear trap"
  5802.  ::= { trapPrefix 20811 }
  5803.  
  5804. t3hdSensorExtBTempNOTIFY NOTIFICATION-TYPE
  5805.  OBJECTS {
  5806.    t3hdSensorExtBTemp,
  5807.    temperatureUnits,
  5808.    trapThreshType,
  5809.    trapSeverity,
  5810.    sysName,
  5811.    t3hdSensorLabel,
  5812.    t3hdSensorExtBLabel
  5813.   }
  5814.  STATUS current
  5815.  DESCRIPTION "T3HD External B temperature trap"
  5816.  ::= { trapPrefix 10814 }
  5817.  
  5818. t3hdSensorExtBTempCLEAR NOTIFICATION-TYPE
  5819.  OBJECTS {
  5820.    t3hdSensorExtBTemp,
  5821.    temperatureUnits,
  5822.    trapThreshType,
  5823.    trapSeverity,
  5824.    sysName,
  5825.    t3hdSensorLabel,
  5826.    t3hdSensorExtBLabel
  5827.   }
  5828.  STATUS current
  5829.  DESCRIPTION "T3HD External B temperature clear trap"
  5830.  ::= { trapPrefix 20814 }
  5831.  
  5832. --#####thdSensorTable#####--
  5833.  
  5834. thdSensorAvailNOTIFY NOTIFICATION-TYPE
  5835.  OBJECTS {
  5836.    thdSensorAvail,
  5837.    trapSeverity,
  5838.    sysName,
  5839.    thdSensorLabel
  5840.   }
  5841.  STATUS current
  5842.  DESCRIPTION "THD availability trap"
  5843.  ::= { trapPrefix 10904 }
  5844.  
  5845. thdSensorAvailCLEAR NOTIFICATION-TYPE
  5846.  OBJECTS {
  5847.    thdSensorAvail,
  5848.    trapSeverity,
  5849.    sysName,
  5850.    thdSensorLabel
  5851.   }
  5852.  STATUS current
  5853.  DESCRIPTION "THD availability clear trap"
  5854.  ::= { trapPrefix 20904 }
  5855.  
  5856. thdSensorTempNOTIFY NOTIFICATION-TYPE
  5857.  OBJECTS {
  5858.    thdSensorTemp,
  5859.    temperatureUnits,
  5860.    trapThreshType,
  5861.    trapSeverity,
  5862.    sysName,
  5863.    thdSensorLabel
  5864.   }
  5865.  STATUS current
  5866.  DESCRIPTION "THD temperature trap"
  5867.  ::= { trapPrefix 10905 }
  5868.  
  5869. thdSensorTempCLEAR NOTIFICATION-TYPE
  5870.  OBJECTS {
  5871.    thdSensorTemp,
  5872.    temperatureUnits,
  5873.    trapThreshType,
  5874.    trapSeverity,
  5875.    sysName,
  5876.    thdSensorLabel
  5877.   }
  5878.  STATUS current
  5879.  DESCRIPTION "THD temperature clear trap"
  5880.  ::= { trapPrefix 20905 }
  5881.  
  5882. thdSensorHumidityNOTIFY NOTIFICATION-TYPE
  5883.  OBJECTS {
  5884.    thdSensorHumidity,
  5885.    trapThreshType,
  5886.    trapSeverity,
  5887.    sysName,
  5888.    thdSensorLabel
  5889.   }
  5890.  STATUS current
  5891.  DESCRIPTION "THD humidity trap"
  5892.  ::= { trapPrefix 10906 }
  5893.  
  5894. thdSensorHumidityCLEAR NOTIFICATION-TYPE
  5895.  OBJECTS {
  5896.    thdSensorHumidity,
  5897.    trapThreshType,
  5898.    trapSeverity,
  5899.    sysName,
  5900.    thdSensorLabel
  5901.   }
  5902.  STATUS current
  5903.  DESCRIPTION "THD humidity clear trap"
  5904.  ::= { trapPrefix 20906 }
  5905.  
  5906. thdSensorDewPointNOTIFY NOTIFICATION-TYPE
  5907.  OBJECTS {
  5908.    thdSensorDewPoint,
  5909.    temperatureUnits,
  5910.    trapThreshType,
  5911.    trapSeverity,
  5912.    sysName,
  5913.    thdSensorLabel
  5914.   }
  5915.  STATUS current
  5916.  DESCRIPTION "THD dewpoint trap"
  5917.  ::= { trapPrefix 10907 }
  5918.  
  5919. thdSensorDewPointCLEAR NOTIFICATION-TYPE
  5920.  OBJECTS {
  5921.    thdSensorDewPoint,
  5922.    temperatureUnits,
  5923.    trapThreshType,
  5924.    trapSeverity,
  5925.    sysName,
  5926.    thdSensorLabel
  5927.   }
  5928.  STATUS current
  5929.  DESCRIPTION "THD dewpoint clear trap"
  5930.  ::= { trapPrefix 20907 }
  5931.  
  5932. --#####a2dSensorTable#####--
  5933.  
  5934. a2dSensorAvailNOTIFY NOTIFICATION-TYPE
  5935.  OBJECTS {
  5936.    a2dSensorAvail,
  5937.    trapSeverity,
  5938.    sysName,
  5939.    a2dSensorLabel
  5940.   }
  5941.  STATUS current
  5942.  DESCRIPTION "A2D availability trap"
  5943.  ::= { trapPrefix 11104 }
  5944.  
  5945. a2dSensorAvailCLEAR NOTIFICATION-TYPE
  5946.  OBJECTS {
  5947.    a2dSensorAvail,
  5948.    trapSeverity,
  5949.    sysName,
  5950.    a2dSensorLabel
  5951.   }
  5952.  STATUS current
  5953.  DESCRIPTION "A2D availability clear trap"
  5954.  ::= { trapPrefix 21104 }
  5955.  
  5956. a2dSensorValueNOTIFY NOTIFICATION-TYPE
  5957.  OBJECTS {
  5958.    a2dSensorValue,
  5959.    trapThreshType,
  5960.    trapSeverity,
  5961.    sysName,
  5962.    a2dSensorLabel,
  5963.    a2dSensorAnalogLabel,
  5964.    a2dSensorDisplayValue
  5965.   }
  5966.  STATUS current
  5967.  DESCRIPTION "A2D measurement trap"
  5968.  ::= { trapPrefix 11105 }
  5969.  
  5970. a2dSensorValueCLEAR NOTIFICATION-TYPE
  5971.  OBJECTS {
  5972.    a2dSensorValue,
  5973.    trapThreshType,
  5974.    trapSeverity,
  5975.    sysName,
  5976.    a2dSensorLabel,
  5977.    a2dSensorAnalogLabel,
  5978.    a2dSensorDisplayValue
  5979.   }
  5980.  STATUS current
  5981.  DESCRIPTION "A2D measurement clear trap"
  5982.  ::= { trapPrefix 21105 }
  5983.  
  5984. --#####humiditySensorTable#####--
  5985.  
  5986. humiditySensorAvailNOTIFY NOTIFICATION-TYPE
  5987.  OBJECTS {
  5988.    humiditySensorAvail,
  5989.    trapSeverity,
  5990.    sysName,
  5991.    humiditySensorLabel
  5992.   }
  5993.  STATUS current
  5994.  DESCRIPTION "Remote humidity availability trap"
  5995.  ::= { trapPrefix 11204 }
  5996.  
  5997. humiditySensorAvailCLEAR NOTIFICATION-TYPE
  5998.  OBJECTS {
  5999.    humiditySensorAvail,
  6000.    trapSeverity,
  6001.    sysName,
  6002.    humiditySensorLabel
  6003.   }
  6004.  STATUS current
  6005.  DESCRIPTION "Remote humidity availability clear trap"
  6006.  ::= { trapPrefix 21204 }
  6007.  
  6008. humiditySensorValueNOTIFY NOTIFICATION-TYPE
  6009.  OBJECTS {
  6010.    humiditySensorValue,
  6011.    trapThreshType,
  6012.    trapSeverity,
  6013.    sysName,
  6014.    humiditySensorLabel
  6015.   }
  6016.  STATUS current
  6017.  DESCRIPTION "Remote humidity value trap"
  6018.  ::= { trapPrefix 11205 }
  6019.  
  6020. humiditySensorValueCLEAR NOTIFICATION-TYPE
  6021.  OBJECTS {
  6022.    humiditySensorValue,
  6023.    trapThreshType,
  6024.    trapSeverity,
  6025.    sysName,
  6026.    humiditySensorLabel
  6027.   }
  6028.  STATUS current
  6029.  DESCRIPTION "Remote humidity value clear trap"
  6030.  ::= { trapPrefix 21205 }
  6031.  
  6032. --#####sn2dSensorTable#####--
  6033.  
  6034. sn2dSensorAvailNOTIFY NOTIFICATION-TYPE
  6035.  OBJECTS {
  6036.    sn2dSensorAvail,
  6037.    trapSeverity,
  6038.    sysName,
  6039.    sn2dSensorLabel
  6040.   }
  6041.  STATUS current
  6042.  DESCRIPTION "SN-2D availability trap"
  6043.  ::= { trapPrefix 11304 }
  6044.  
  6045. sn2dSensorAvailCLEAR NOTIFICATION-TYPE
  6046.  OBJECTS {
  6047.    sn2dSensorAvail,
  6048.    trapSeverity,
  6049.    sysName,
  6050.    sn2dSensorLabel
  6051.   }
  6052.  STATUS current
  6053.  DESCRIPTION "SN-2D availability clear trap"
  6054.  ::= { trapPrefix 21304 }
  6055.  
  6056. sn2dSensorDoor1StateNOTIFY NOTIFICATION-TYPE
  6057.  OBJECTS {
  6058.    sn2dSensorDoor1State,
  6059.    trapThreshType,
  6060.    trapSeverity,
  6061.    sysName,
  6062.    sn2dSensorLabel,
  6063.    sn2dSensorDoor1Label,
  6064.    sn2dSensorDoor1DisplayState
  6065.   }
  6066.  STATUS current
  6067.  DESCRIPTION "SN-2D Door switch 1 state trap"
  6068.  ::= { trapPrefix 11306 }
  6069.  
  6070. sn2dSensorDoor1StateCLEAR NOTIFICATION-TYPE
  6071.  OBJECTS {
  6072.    sn2dSensorDoor1State,
  6073.    trapThreshType,
  6074.    trapSeverity,
  6075.    sysName,
  6076.    sn2dSensorLabel,
  6077.    sn2dSensorDoor1Label,
  6078.    sn2dSensorDoor1DisplayState
  6079.   }
  6080.  STATUS current
  6081.  DESCRIPTION "SN-2D Door switch 1 state clear trap"
  6082.  ::= { trapPrefix 21306 }
  6083.  
  6084. sn2dSensorDoor2StateNOTIFY NOTIFICATION-TYPE
  6085.  OBJECTS {
  6086.    sn2dSensorDoor2State,
  6087.    trapThreshType,
  6088.    trapSeverity,
  6089.    sysName,
  6090.    sn2dSensorLabel,
  6091.    sn2dSensorDoor2Label,
  6092.    sn2dSensorDoor2DisplayState
  6093.   }
  6094.  STATUS current
  6095.  DESCRIPTION "SN-2D Door switch 2 state trap"
  6096.  ::= { trapPrefix 11309 }
  6097.  
  6098. sn2dSensorDoor2StateCLEAR NOTIFICATION-TYPE
  6099.  OBJECTS {
  6100.    sn2dSensorDoor2State,
  6101.    trapThreshType,
  6102.    trapSeverity,
  6103.    sysName,
  6104.    sn2dSensorLabel,
  6105.    sn2dSensorDoor2Label,
  6106.    sn2dSensorDoor2DisplayState
  6107.   }
  6108.  STATUS current
  6109.  DESCRIPTION "SN-2D Door switch 2 state clear trap"
  6110.  ::= { trapPrefix 21309 }
  6111.  
  6112. --#####cooling#####--
  6113.  
  6114. --#####vrc#####--
  6115.  
  6116. --#####vrcMainTable#####--
  6117.  
  6118. vrcMainAvailNOTIFY NOTIFICATION-TYPE
  6119.  OBJECTS {
  6120.    vrcMainAvail,
  6121.    trapSeverity,
  6122.    sysName,
  6123.    vrcMainLabel
  6124.   }
  6125.  STATUS current
  6126.  DESCRIPTION "VRC availability trap"
  6127.  ::= { trapPrefix 13001 }
  6128.  
  6129. vrcMainAvailCLEAR NOTIFICATION-TYPE
  6130.  OBJECTS {
  6131.    vrcMainAvail,
  6132.    trapSeverity,
  6133.    sysName,
  6134.    vrcMainLabel
  6135.   }
  6136.  STATUS current
  6137.  DESCRIPTION "VRC availability clear trap"
  6138.  ::= { trapPrefix 23001 }
  6139.  
  6140. --#####vrcMainPtTable#####--
  6141.  
  6142. --#####vrcMainCfgTable#####--
  6143.  
  6144. --#####vrcOutFanPtTable#####--
  6145.  
  6146. vrcOutFanPtSpeedNOTIFY NOTIFICATION-TYPE
  6147.  OBJECTS {
  6148.    vrcOutFanPtSpeed,
  6149.    trapThreshType,
  6150.    trapSeverity,
  6151.    sysName,
  6152.    vrcMainLabel
  6153.   }
  6154.  STATUS current
  6155.  DESCRIPTION "VRC out-fan speed trap"
  6156.  ::= { trapPrefix 13002 }
  6157.  
  6158. vrcOutFanPtSpeedCLEAR NOTIFICATION-TYPE
  6159.  OBJECTS {
  6160.    vrcOutFanPtSpeed,
  6161.    trapThreshType,
  6162.    trapSeverity,
  6163.    sysName,
  6164.    vrcMainLabel
  6165.   }
  6166.  STATUS current
  6167.  DESCRIPTION "VRC out-fan speed clear trap"
  6168.  ::= { trapPrefix 23002 }
  6169.  
  6170. --#####vrcOutFanCfgTable#####--
  6171.  
  6172. --#####vrcInFanPtTable#####--
  6173.  
  6174. --#####vrcInFanCfgTable#####--
  6175.  
  6176. --#####vrcCompPtTable#####--
  6177.  
  6178. vrcCompPtCapacityNOTIFY NOTIFICATION-TYPE
  6179.  OBJECTS {
  6180.    vrcCompPtCapacity,
  6181.    trapThreshType,
  6182.    trapSeverity,
  6183.    sysName,
  6184.    vrcMainLabel
  6185.   }
  6186.  STATUS current
  6187.  DESCRIPTION "VRC compressor capacity trap"
  6188.  ::= { trapPrefix 13003 }
  6189.  
  6190. vrcCompPtCapacityCLEAR NOTIFICATION-TYPE
  6191.  OBJECTS {
  6192.    vrcCompPtCapacity,
  6193.    trapThreshType,
  6194.    trapSeverity,
  6195.    sysName,
  6196.    vrcMainLabel
  6197.   }
  6198.  STATUS current
  6199.  DESCRIPTION "VRC compressor capacity clear trap"
  6200.  ::= { trapPrefix 23003 }
  6201.  
  6202. --#####vrcCompCfgTable#####--
  6203.  
  6204. --#####vrcReturnPtTable#####--
  6205.  
  6206. vrcReturnPtTempNOTIFY NOTIFICATION-TYPE
  6207.  OBJECTS {
  6208.    vrcReturnPtTemp,
  6209.    temperatureUnits,
  6210.    trapThreshType,
  6211.    trapSeverity,
  6212.    sysName,
  6213.    vrcMainLabel
  6214.   }
  6215.  STATUS current
  6216.  DESCRIPTION "VRC return temperature trap"
  6217.  ::= { trapPrefix 13004 }
  6218.  
  6219. vrcReturnPtTempCLEAR NOTIFICATION-TYPE
  6220.  OBJECTS {
  6221.    vrcReturnPtTemp,
  6222.    temperatureUnits,
  6223.    trapThreshType,
  6224.    trapSeverity,
  6225.    sysName,
  6226.    vrcMainLabel
  6227.   }
  6228.  STATUS current
  6229.  DESCRIPTION "VRC return temperature clear trap"
  6230.  ::= { trapPrefix 23004 }
  6231.  
  6232. --#####vrcReturnCfgTable#####--
  6233.  
  6234. --#####vrcSupplyPtTable#####--
  6235.  
  6236. vrcSupplyPtTempNOTIFY NOTIFICATION-TYPE
  6237.  OBJECTS {
  6238.    vrcSupplyPtTemp,
  6239.    temperatureUnits,
  6240.    trapThreshType,
  6241.    trapSeverity,
  6242.    sysName,
  6243.    vrcMainLabel
  6244.   }
  6245.  STATUS current
  6246.  DESCRIPTION "VRC supply temperature trap"
  6247.  ::= { trapPrefix 13005 }
  6248.  
  6249. vrcSupplyPtTempCLEAR NOTIFICATION-TYPE
  6250.  OBJECTS {
  6251.    vrcSupplyPtTemp,
  6252.    temperatureUnits,
  6253.    trapThreshType,
  6254.    trapSeverity,
  6255.    sysName,
  6256.    vrcMainLabel
  6257.   }
  6258.  STATUS current
  6259.  DESCRIPTION "VRC supply temperature clear trap"
  6260.  ::= { trapPrefix 23005 }
  6261.  
  6262. --#####vrcSupplyCfgTable#####--
  6263.  
  6264. --#####vrcPowerPtTable#####--
  6265.  
  6266. vrcPowerPtVoltageNOTIFY NOTIFICATION-TYPE
  6267.  OBJECTS {
  6268.    vrcPowerPtVoltage,
  6269.    trapThreshType,
  6270.    trapSeverity,
  6271.    sysName,
  6272.    vrcMainLabel
  6273.   }
  6274.  STATUS current
  6275.  DESCRIPTION "VRC power voltage trap"
  6276.  ::= { trapPrefix 13006 }
  6277.  
  6278. vrcPowerPtVoltageCLEAR NOTIFICATION-TYPE
  6279.  OBJECTS {
  6280.    vrcPowerPtVoltage,
  6281.    trapThreshType,
  6282.    trapSeverity,
  6283.    sysName,
  6284.    vrcMainLabel
  6285.   }
  6286.  STATUS current
  6287.  DESCRIPTION "VRC power voltage clear trap"
  6288.  ::= { trapPrefix 23006 }
  6289.  
  6290. vrcPowerPtFrequencyNOTIFY NOTIFICATION-TYPE
  6291.  OBJECTS {
  6292.    vrcPowerPtFrequency,
  6293.    trapThreshType,
  6294.    trapSeverity,
  6295.    sysName,
  6296.    vrcMainLabel
  6297.   }
  6298.  STATUS current
  6299.  DESCRIPTION "VRC power frequency trap"
  6300.  ::= { trapPrefix 13007 }
  6301.  
  6302. vrcPowerPtFrequencyCLEAR NOTIFICATION-TYPE
  6303.  OBJECTS {
  6304.    vrcPowerPtFrequency,
  6305.    trapThreshType,
  6306.    trapSeverity,
  6307.    sysName,
  6308.    vrcMainLabel
  6309.   }
  6310.  STATUS current
  6311.  DESCRIPTION "VRC power frequency clear trap"
  6312.  ::= { trapPrefix 23007 }
  6313.  
  6314. --#####vrcPowerCfgTable#####--
  6315.  
  6316. --#####vrcOutdoorPtTable#####--
  6317.  
  6318. vrcOutdoorPtTempNOTIFY NOTIFICATION-TYPE
  6319.  OBJECTS {
  6320.    vrcOutdoorPtTemp,
  6321.    temperatureUnits,
  6322.    trapThreshType,
  6323.    trapSeverity,
  6324.    sysName,
  6325.    vrcMainLabel
  6326.   }
  6327.  STATUS current
  6328.  DESCRIPTION "VRC outdoor temperature trap"
  6329.  ::= { trapPrefix 13008 }
  6330.  
  6331. vrcOutdoorPtTempCLEAR NOTIFICATION-TYPE
  6332.  OBJECTS {
  6333.    vrcOutdoorPtTemp,
  6334.    temperatureUnits,
  6335.    trapThreshType,
  6336.    trapSeverity,
  6337.    sysName,
  6338.    vrcMainLabel
  6339.   }
  6340.  STATUS current
  6341.  DESCRIPTION "VRC outdoor temperature clear trap"
  6342.  ::= { trapPrefix 23008 }
  6343.  
  6344. --#####vrcDischPtTable#####--
  6345.  
  6346. vrcDischPtTempNOTIFY NOTIFICATION-TYPE
  6347.  OBJECTS {
  6348.    vrcDischPtTemp,
  6349.    temperatureUnits,
  6350.    trapThreshType,
  6351.    trapSeverity,
  6352.    sysName,
  6353.    vrcMainLabel
  6354.   }
  6355.  STATUS current
  6356.  DESCRIPTION "VRC discharge temperature trap"
  6357.  ::= { trapPrefix 13009 }
  6358.  
  6359. vrcDischPtTempCLEAR NOTIFICATION-TYPE
  6360.  OBJECTS {
  6361.    vrcDischPtTemp,
  6362.    temperatureUnits,
  6363.    trapThreshType,
  6364.    trapSeverity,
  6365.    sysName,
  6366.    vrcMainLabel
  6367.   }
  6368.  STATUS current
  6369.  DESCRIPTION "VRC discharge temperature clear trap"
  6370.  ::= { trapPrefix 23009 }
  6371.  
  6372. vrcDischPtPressureNOTIFY NOTIFICATION-TYPE
  6373.  OBJECTS {
  6374.    vrcDischPtPressure,
  6375.    trapThreshType,
  6376.    trapSeverity,
  6377.    sysName,
  6378.    vrcMainLabel
  6379.   }
  6380.  STATUS current
  6381.  DESCRIPTION "VRC discharge pressure trap"
  6382.  ::= { trapPrefix 13010 }
  6383.  
  6384. vrcDischPtPressureCLEAR NOTIFICATION-TYPE
  6385.  OBJECTS {
  6386.    vrcDischPtPressure,
  6387.    trapThreshType,
  6388.    trapSeverity,
  6389.    sysName,
  6390.    vrcMainLabel
  6391.   }
  6392.  STATUS current
  6393.  DESCRIPTION "VRC discharge pressure clear trap"
  6394.  ::= { trapPrefix 23010 }
  6395.  
  6396. --#####vrcDischCfgTable#####--
  6397.  
  6398. --#####vrcSuctPtTable#####--
  6399.  
  6400. vrcSuctPtTempNOTIFY NOTIFICATION-TYPE
  6401.  OBJECTS {
  6402.    vrcSuctPtTemp,
  6403.    temperatureUnits,
  6404.    trapThreshType,
  6405.    trapSeverity,
  6406.    sysName,
  6407.    vrcMainLabel
  6408.   }
  6409.  STATUS current
  6410.  DESCRIPTION "VRC suction temperature trap"
  6411.  ::= { trapPrefix 13011 }
  6412.  
  6413. vrcSuctPtTempCLEAR NOTIFICATION-TYPE
  6414.  OBJECTS {
  6415.    vrcSuctPtTemp,
  6416.    temperatureUnits,
  6417.    trapThreshType,
  6418.    trapSeverity,
  6419.    sysName,
  6420.    vrcMainLabel
  6421.   }
  6422.  STATUS current
  6423.  DESCRIPTION "VRC suction temperature clear trap"
  6424.  ::= { trapPrefix 23011 }
  6425.  
  6426. vrcSuctPtPressureNOTIFY NOTIFICATION-TYPE
  6427.  OBJECTS {
  6428.    vrcSuctPtPressure,
  6429.    trapThreshType,
  6430.    trapSeverity,
  6431.    sysName,
  6432.    vrcMainLabel
  6433.   }
  6434.  STATUS current
  6435.  DESCRIPTION "VRC suction pressure trap"
  6436.  ::= { trapPrefix 13012 }
  6437.  
  6438. vrcSuctPtPressureCLEAR NOTIFICATION-TYPE
  6439.  OBJECTS {
  6440.    vrcSuctPtPressure,
  6441.    trapThreshType,
  6442.    trapSeverity,
  6443.    sysName,
  6444.    vrcMainLabel
  6445.   }
  6446.  STATUS current
  6447.  DESCRIPTION "VRC suction pressure clear trap"
  6448.  ::= { trapPrefix 23012 }
  6449.  
  6450. --#####vrcSuctCfgTable#####--
  6451.  
  6452. --###########################################################################################--
  6453. --common group--
  6454. --###########################################################################################--
  6455.  
  6456. common OBJECT IDENTIFIER ::= { vertiv 42 }
  6457.  
  6458. identity OBJECT IDENTIFIER ::= { common 1 }
  6459.  
  6460. i03 OBJECT-IDENTITY
  6461.  STATUS current
  6462.  DESCRIPTION
  6463.   "Value given for sysObjectID on IMD3 units"
  6464.  ::= { identity 53 }
  6465.  
  6466. r05 OBJECT-IDENTITY
  6467.  STATUS current
  6468.  DESCRIPTION
  6469.   "Value given for sysObjectID on R-Series units"
  6470.  ::= { identity 15 }