From root, 5 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.71ms]
  3. SQL[[1;33mSELECT version() [0;33m[][0m 0.46ms]
  4. ===================================
  5. Version info:
  6. Commit SHA: 4e8acdd894d9a5fb3d03b23a31dfd97f373a9ca0
  7. Commit Date: 1541405427
  8. DB Schema: 270
  9. PHP: 7.2.11
  10. MySQL: 10.2.18-MariaDB
  11. RRDTool: 1.6.0
  12. SNMP: NET-SNMP 5.7.2
  13. ==================================DEBUG!
  14. Updating os_def.cache... Done
  15. SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.0.100.157' ORDER BY device_id DESC [0;33m[][0m 0.7ms]
  16. SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[23][0m 0.37ms]
  17. 10.0.100.157 23 valere [FPING] /usr/sbin/fping -e -q -c 3 -p 500 -t 500 10.0.100.157
  18. Array
  19. (
  20.     [xmt] => 3
  21.     [rcv] => 3
  22.     [loss] => 0
  23.     [min] => 0.62
  24.     [max] => 1.38
  25.     [avg] => 0.87
  26.     [exitcode] => 0
  27. )
  28. SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.62","max":"1.38","avg":"0.87","device_id":23}[0m 2.45ms]
  29. SNMP Check response code: 0
  30. SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ?  [0;33m[23,"poll_mib"][0m 0.87ms]
  31. Attempting to initialize OS: valere
  32. OS initilized as Generic
  33.  
  34. Modules status: Global+ OS  Device  
  35. #### Load disco module core ####
  36. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
  37. .*.*.0 = Eltek Compact Shelf            
  38. .*.*.0 = .*.4.1.13858
  39. .*.*.0 = Sys Description                
  40.  
  41.  
  42. >> Runtime for discovery module 'core': 0.0190 seconds with 984 bytes
  43. >> SNMP: [2/0.07s] MySQL: [4/0.01s] RRD: [0/0.00s]
  44. #### Unload disco module core ####
  45.  
  46. Modules status: Global+ OS+ Device  
  47. #### Load disco module os ####
  48. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
  49. Sys Description                
  50.  
  51. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
  52. .*.4.1.13858
  53.  
  54. | Sys Description | .1.3.6.1.4.1.13858 |
  55. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m]
  56.  
  57. OS: Eltek Valere (valere)
  58.  
  59. >> Runtime for discovery module 'os': 0.1470 seconds with 1336 bytes
  60. >> SNMP: [3/0.15s] MySQL: [0/0.00s] RRD: [0/0.00s]
  61. #### Unload disco module os ####
  62.  
  63. Modules status: Global+ OS+ Device  
  64. #### Load disco module ports ####
  65. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifDescr[0m]
  66. ifDescr.1 = Ethernet Interface
  67.  
  68. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifName[0m]
  69.  
  70. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifAlias[0m]
  71.  
  72. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifType[0m]
  73. ifType.1 = ethernetCsmacd
  74.  
  75. Array
  76. (
  77.     [1] => Array
  78.         (
  79.             [ifDescr] => Ethernet Interface
  80.             [ifType] => ethernetCsmacd
  81.         )
  82.  
  83. )
  84. SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[23][0m 1.77ms]
  85. .
  86.  
  87. >> Runtime for discovery module 'ports': 0.0970 seconds with 4152 bytes
  88. >> SNMP: [4/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s]
  89. #### Unload disco module ports ####
  90.  
  91. Modules status: Global+ OS+ Device  
  92. #### Load disco module ports-stack ####
  93. SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '23' [0;33m[][0m 1.03ms]
  94. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY  -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifStackStatus[0m]
  95.  
  96.  
  97.  
  98. >> Runtime for discovery module 'ports-stack': 0.0260 seconds with 1736 bytes
  99. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  100. #### Unload disco module ports-stack ####
  101.  
  102. Modules status: Global+ OS+ Device  
  103. #### Load disco module entity-physical ####
  104.  
  105. Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 entPhysicalEntry[0m]
  106.  
  107.  
  108. SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[23][0m 1.26ms]
  109.  
  110. >> Runtime for discovery module 'entity-physical': 0.0530 seconds with 5456 bytes
  111. >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
  112. #### Unload disco module entity-physical ####
  113.  
  114. Modules status: Global- OS- Device  Module [ entity-state ] disabled on os.
  115.  
  116. Modules status: Global+ OS+ Device  
  117. #### Load disco module processors ####
  118. No YAML Discovery data.
  119. Host Resources: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrProcessorLoad[0m]
  120.  
  121. UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[23][0m 1.39ms]
  122. SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[23][0m 0.57ms]
  123. SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[23][0m 0.59ms]
  124. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m]
  125.  
  126. SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[23][0m 0.97ms]
  127. SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.04ms]
  128.  
  129.  
  130. >> Runtime for discovery module 'processors': 0.0870 seconds with 139520 bytes
  131. >> SNMP: [2/0.08s] MySQL: [5/0.01s] RRD: [0/0.00s]
  132. #### Unload disco module processors ####
  133.  
  134. Modules status: Global+ OS+ Device  
  135. #### Load disco module mempools ####
  136. SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[23][0m 0.7ms]
  137. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
  138.  
  139. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
  140.  
  141. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrStorageEntry[0m]
  142.  
  143. SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id`  = '23' [0;33m[][0m 0.98ms]
  144.  
  145.  
  146. >> Runtime for discovery module 'mempools': 0.1140 seconds with 28600 bytes
  147. >> SNMP: [3/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s]
  148. #### Unload disco module mempools ####
  149.  
  150. Modules status: Global+ OS+ Device  
  151. #### Load disco module cisco-vrf-lite ####
  152. SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ?  [0;33m[23][0m 0.43ms]
  153.  
  154. >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2664 bytes
  155. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  156. #### Unload disco module cisco-vrf-lite ####
  157.  
  158. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  159.  
  160. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  161.  
  162. Modules status: Global- OS- Device  Module [ vrf ] disabled on os.
  163.  
  164. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  165.  
  166. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  167.  
  168. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  169.  
  170. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  171.  
  172. Modules status: Global+ OS+ Device  
  173. #### Load disco module ipv4-addresses ####
  174. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAdEntIfIndex[0m]
  175. ipAdEntIfIndex.* 1
  176.  
  177. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAdEntNetMask.10.0.100.157[0m]
  178. *
  179.  
  180. SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[23,"1"][0m 0.69ms]
  181. SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[23,"1"][0m 0.55ms]
  182. SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.100.157\/23"][0m 0.94ms]
  183. SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.0.100.157\/23"][0m 1ms]
  184. sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.100.157\/23"][0m 0.9ms]
  185. SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ?  [0;33m["10.0.100.157",23,121][0m 0.66ms]
  186. SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.0.100.157",23,121][0m 0.51ms]
  187. .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[23][0m 3.9ms]
  188.  
  189.  
  190. >> Runtime for discovery module 'ipv4-addresses': 0.0530 seconds with 34328 bytes
  191. >> SNMP: [2/0.04s] MySQL: [3/0.01s] RRD: [0/0.00s]
  192. #### Unload disco module ipv4-addresses ####
  193.  
  194. Modules status: Global+ OS+ Device  
  195. #### Load disco module ipv6-addresses ####
  196. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
  197.  
  198. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
  199.  
  200. SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[23][0m 0.99ms]
  201.  
  202.  
  203. >> Runtime for discovery module 'ipv6-addresses': 0.0490 seconds with 3384 bytes
  204. >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
  205. #### Unload disco module ipv6-addresses ####
  206.  
  207. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  208.  
  209. Modules status: Global+ OS+ Device  
  210. #### Load disco module sensors ####
  211. Caching data: sensors SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OteQUs -Ih -m VALERE-DC-POWER-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 vpwrSystemParameterGroup[0m]
  212. vpwrSystemShelfCapacity.0 = 2
  213. vpwrSystemVoltage.0 = 5408
  214. vpwrSystemCurrent.0 = 5
  215. vpwrSystemControllerState.0 = 3
  216. vpwrSystemInternalTemperature.0 = 27
  217. vpwrSystemTempCompensationState.0 = 0
  218. vpwrSystemType.0 = 0
  219. vpwrSystemParameterGroup.8.0 = 484214900
  220. vpwrSystemParameterGroup.9.0 = 8
  221.  
  222.  
  223.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 entPhysicalDescr[0m]
  224.  
  225.  
  226. SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ?  [0;33m[23,"ipmi_hostname"][0m 0.85ms]
  227. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",23,"ipmi"][0m 1.28ms]
  228. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",23,"ipmi"][0m 1.16ms]
  229. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",23,"ipmi"][0m 1.08ms]
  230. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",23,"ipmi"][0m 1.11ms]
  231. Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",23,"snmp"][0m 1.06ms]
  232.  
  233. Current: Dynamic Discovery (current): Array
  234. (
  235.     [data] => Array
  236.         (
  237.             [0] => Array
  238.                 (
  239.                     [oid] => vpwrSystemParameterGroup
  240.                     [value] => vpwrSystemCurrent
  241.                     [num_oid] => .1.3.6.1.4.1.13858.2.3.3.
  242.                     [descr] => System Current
  243.                 )
  244.  
  245.         )
  246.  
  247. )
  248. Data vpwrSystemParameterGroup: Array
  249. (
  250.     [0] => Array
  251.         (
  252.             [vpwrSystemShelfCapacity] => 2
  253.             [vpwrSystemVoltage] => 5408
  254.             [vpwrSystemCurrent] => 5
  255.             [vpwrSystemControllerState] => 3
  256.             [vpwrSystemInternalTemperature] => 27
  257.             [vpwrSystemTempCompensationState] => 0
  258.             [vpwrSystemType] => 0
  259.         )
  260.  
  261.     [8.0] => Array
  262.         (
  263.             [vpwrSystemParameterGroup] => 484214900
  264.         )
  265.  
  266.     [9.0] => Array
  267.         (
  268.             [vpwrSystemParameterGroup] => 8
  269.         )
  270.  
  271. )
  272. Final sensor value: 5
  273. Cur 5, Low: null, Low Warn: null, Warn: null, High: null
  274. Discover sensor: .1.3.6.1.4.1.13858.2.3.3.0, 0, valere, System Current, snmp, 1, 1, , 5
  275. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",23,"valere","0"][0m 0.86ms]
  276. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",23,"valere","0"][0m 0.92ms]
  277. .Final sensor value:
  278. Final sensor value:
  279. Array
  280. (
  281.     [valere] => Array
  282.         (
  283.             [0] => 1
  284.         )
  285.  
  286. )
  287. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",23,"snmp"][0m 1.15ms]
  288. 0 -> valere
  289.  
  290. Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",23,"snmp"][0m 1.11ms]
  291.  
  292. Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",23,"snmp"][0m 1.13ms]
  293.  
  294. Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",23,"snmp"][0m 1.06ms]
  295.  
  296. Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",23,"snmp"][0m 1.24ms]
  297.  
  298. Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",23,"snmp"][0m 1.12ms]
  299.  
  300. Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",23,"snmp"][0m 1.08ms]
  301.  
  302. Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",23,"snmp"][0m 1.1ms]
  303.  
  304. Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",23,"snmp"][0m 1.07ms]
  305.  
  306. Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",23,"snmp"][0m 1.06ms]
  307.  
  308. State: Dynamic Discovery (state): Array
  309. (
  310.     [data] => Array
  311.         (
  312.             [0] => Array
  313.                 (
  314.                     [oid] => vpwrSystemParameterGroup
  315.                     [value] => vpwrSystemControllerState
  316.                     [num_oid] => .1.3.6.1.4.1.13858.2.3.4.
  317.                     [descr] => Controller State
  318.                     [state_name] => vpwrSystemControllerState
  319.                     [states] => Array
  320.                         (
  321.                             [0] => Array
  322.                                 (
  323.                                     [descr] => systemControllerStateUnknown
  324.                                     [graph] => 0
  325.                                     [value] => 0
  326.                                     [generic] => 3
  327.                                 )
  328.  
  329.                             [1] => Array
  330.                                 (
  331.                                     [descr] => systemControllerStateNormal
  332.                                     [graph] => 0
  333.                                     [value] => 1
  334.                                     [generic] => 0
  335.                                 )
  336.  
  337.                             [2] => Array
  338.                                 (
  339.                                     [descr] => systemControllerStateChange
  340.                                     [graph] => 0
  341.                                     [value] => 2
  342.                                     [generic] => 1
  343.                                 )
  344.  
  345.                             [3] => Array
  346.                                 (
  347.                                     [descr] => systemControllerStateAlarm
  348.                                     [graph] => 0
  349.                                     [value] => 3
  350.                                     [generic] => 2
  351.                                 )
  352.  
  353.                             [4] => Array
  354.                                 (
  355.                                     [descr] => systemControllerStateMenu
  356.                                     [graph] => 0
  357.                                     [value] => 4
  358.                                     [generic] => 1
  359.                                 )
  360.  
  361.                             [5] => Array
  362.                                 (
  363.                                     [descr] => systemControllerStateIrActive
  364.                                     [graph] => 0
  365.                                     [value] => 5
  366.                                     [generic] => 1
  367.                                 )
  368.  
  369.                         )
  370.  
  371.                 )
  372.  
  373.             [1] => Array
  374.                 (
  375.                     [oid] => vpwrSystemParameterGroup
  376.                     [value] => vpwrSystemTempCompensationState
  377.                     [num_oid] => .1.3.6.1.4.1.13858.2.3.4.
  378.                     [descr] => Temperature Compensation State
  379.                     [state_name] => vpwrSystemTempCompensationState
  380.                     [states] => Array
  381.                         (
  382.                             [0] => Array
  383.                                 (
  384.                                     [descr] => systemTempCompInactive
  385.                                     [graph] => 0
  386.                                     [value] => 0
  387.                                     [generic] => 0
  388.                                 )
  389.  
  390.                             [1] => Array
  391.                                 (
  392.                                     [descr] => systemTempCompActive
  393.                                     [graph] => 0
  394.                                     [value] => 1
  395.                                     [generic] => 1
  396.                                 )
  397.  
  398.                         )
  399.  
  400.                 )
  401.  
  402.         )
  403.  
  404. )
  405. Data vpwrSystemParameterGroup: Array
  406. (
  407.     [0] => Array
  408.         (
  409.             [vpwrSystemShelfCapacity] => 2
  410.             [vpwrSystemVoltage] => 5408
  411.             [vpwrSystemCurrent] => 5
  412.             [vpwrSystemControllerState] => 3
  413.             [vpwrSystemInternalTemperature] => 27
  414.             [vpwrSystemTempCompensationState] => 0
  415.             [vpwrSystemType] => 0
  416.         )
  417.  
  418.     [8.0] => Array
  419.         (
  420.             [vpwrSystemParameterGroup] => 484214900
  421.         )
  422.  
  423.     [9.0] => Array
  424.         (
  425.             [vpwrSystemParameterGroup] => 8
  426.         )
  427.  
  428. )
  429. Final sensor value: 3
  430. Cur 3, Low: null, Low Warn: null, Warn: null, High: null
  431. SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["vpwrSystemControllerState"][0m 0.63ms]
  432. SQL[[1;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [0;33m[8][0m 0.61ms]
  433. Discover sensor: .1.3.6.1.4.1.13858.2.3.4.0, 0, vpwrSystemControllerState, Controller State, snmp, 1, 1, , 3
  434. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",23,"vpwrSystemControllerState","0"][0m 0.73ms]
  435. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemControllerState","0"][0m 0.85ms]
  436. .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemControllerState","0"][0m 0.73ms]
  437. SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["vpwrSystemControllerState"][0m 0.52ms]
  438. SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":234,"state_index_id":8}[0m 2.57ms]
  439. Final sensor value:
  440. Final sensor value:
  441. Data vpwrSystemParameterGroup: Array
  442. (
  443.     [0] => Array
  444.         (
  445.             [vpwrSystemShelfCapacity] => 2
  446.             [vpwrSystemVoltage] => 5408
  447.             [vpwrSystemCurrent] => 5
  448.             [vpwrSystemControllerState] => 3
  449.             [vpwrSystemInternalTemperature] => 27
  450.             [vpwrSystemTempCompensationState] => 0
  451.             [vpwrSystemType] => 0
  452.         )
  453.  
  454.     [8.0] => Array
  455.         (
  456.             [vpwrSystemParameterGroup] => 484214900
  457.         )
  458.  
  459.     [9.0] => Array
  460.         (
  461.             [vpwrSystemParameterGroup] => 8
  462.         )
  463.  
  464. )
  465. Final sensor value: 0
  466. Cur 0, Low: null, Low Warn: null, Warn: null, High: null
  467. SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["vpwrSystemTempCompensationState"][0m 0.54ms]
  468. SQL[[1;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [0;33m[9][0m 0.62ms]
  469. Discover sensor: .1.3.6.1.4.1.13858.2.3.4.0, 0, vpwrSystemTempCompensationState, Temperature Compensation State, snmp, 1, 1, , 0
  470. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",23,"vpwrSystemTempCompensationState","0"][0m 0.74ms]
  471. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemTempCompensationState","0"][0m 0.85ms]
  472. .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemTempCompensationState","0"][0m 0.7ms]
  473. SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["vpwrSystemTempCompensationState"][0m 0.53ms]
  474. SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":235,"state_index_id":9}[0m 2.41ms]
  475. Final sensor value:
  476. Final sensor value:
  477. Array
  478. (
  479.     [vpwrSystemControllerState] => Array
  480.         (
  481.             [0] => 1
  482.         )
  483.  
  484.     [vpwrSystemTempCompensationState] => Array
  485.         (
  486.             [0] => 1
  487.         )
  488.  
  489. )
  490. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",23,"snmp"][0m 1.24ms]
  491. 0 -> vpwrSystemControllerState
  492. 0 -> vpwrSystemTempCompensationState
  493.  
  494. Temperature: Dynamic Discovery (temperature): Array
  495. (
  496.     [data] => Array
  497.         (
  498.             [0] => Array
  499.                 (
  500.                     [oid] => vpwrSystemParameterGroup
  501.                     [value] => vpwrSystemInternalTemperature
  502.                     [num_oid] => .1.3.6.1.4.1.13858.2.3.5.
  503.                     [descr] => Internal Temperature
  504.                 )
  505.  
  506.         )
  507.  
  508. )
  509. Data vpwrSystemParameterGroup: Array
  510. (
  511.     [0] => Array
  512.         (
  513.             [vpwrSystemShelfCapacity] => 2
  514.             [vpwrSystemVoltage] => 5408
  515.             [vpwrSystemCurrent] => 5
  516.             [vpwrSystemControllerState] => 3
  517.             [vpwrSystemInternalTemperature] => 27
  518.             [vpwrSystemTempCompensationState] => 0
  519.             [vpwrSystemType] => 0
  520.         )
  521.  
  522.     [8.0] => Array
  523.         (
  524.             [vpwrSystemParameterGroup] => 484214900
  525.         )
  526.  
  527.     [9.0] => Array
  528.         (
  529.             [vpwrSystemParameterGroup] => 8
  530.         )
  531.  
  532. )
  533. Final sensor value: 27
  534. Cur 27, Low: null, Low Warn: null, Warn: null, High: null
  535. Discover sensor: .1.3.6.1.4.1.13858.2.3.5.0, 0, valere, Internal Temperature, snmp, 1, 1, , 27
  536. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",23,"valere","0"][0m 0.82ms]
  537. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",23,"valere","0"][0m 0.91ms]
  538. .Final sensor value:
  539. Final sensor value:
  540. Array
  541. (
  542.     [valere] => Array
  543.         (
  544.             [0] => 1
  545.         )
  546.  
  547. )
  548. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",23,"snmp"][0m 1.23ms]
  549. 0 -> valere
  550.  
  551. Voltage: Dynamic Discovery (voltage): Array
  552. (
  553.     [data] => Array
  554.         (
  555.             [0] => Array
  556.                 (
  557.                     [oid] => vpwrSystemParameterGroup
  558.                     [value] => vpwrSystemVoltage
  559.                     [num_oid] => .1.3.6.1.4.1.13858.2.3.2.
  560.                     [descr] => System Voltage
  561.                     [divisor] => 100
  562.                 )
  563.  
  564.         )
  565.  
  566. )
  567. Data vpwrSystemParameterGroup: Array
  568. (
  569.     [0] => Array
  570.         (
  571.             [vpwrSystemShelfCapacity] => 2
  572.             [vpwrSystemVoltage] => 5408
  573.             [vpwrSystemCurrent] => 5
  574.             [vpwrSystemControllerState] => 3
  575.             [vpwrSystemInternalTemperature] => 27
  576.             [vpwrSystemTempCompensationState] => 0
  577.             [vpwrSystemType] => 0
  578.         )
  579.  
  580.     [8.0] => Array
  581.         (
  582.             [vpwrSystemParameterGroup] => 484214900
  583.         )
  584.  
  585.     [9.0] => Array
  586.         (
  587.             [vpwrSystemParameterGroup] => 8
  588.         )
  589.  
  590. )
  591. Final sensor value: 5408
  592. Cur 5408, Low: null, Low Warn: null, Warn: null, High: null
  593. Discover sensor: .1.3.6.1.4.1.13858.2.3.2.0, 0, valere, System Voltage, snmp, 100, 1, , 54.08
  594. SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",23,"valere","0"][0m 0.77ms]
  595. SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",23,"valere","0"][0m 0.9ms]
  596. .Final sensor value:
  597. Final sensor value:
  598. Array
  599. (
  600.     [valere] => Array
  601.         (
  602.             [0] => 1
  603.         )
  604.  
  605. )
  606. SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",23,"snmp"][0m 1.16ms]
  607. 0 -> valere
  608.  
  609. Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",23,"snmp"][0m 1.06ms]
  610.  
  611. Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",23,"snmp"][0m 1.05ms]
  612.  
  613. Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",23,"snmp"][0m 1.05ms]
  614.  
  615. Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",23,"snmp"][0m 1.06ms]
  616.  
  617. Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",23,"snmp"][0m 1.06ms]
  618.  
  619. Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",23,"snmp"][0m 1.06ms]
  620.  
  621. Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",23,"snmp"][0m 1.05ms]
  622.  
  623. Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",23,"snmp"][0m 1.08ms]
  624.  
  625. Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",23,"snmp"][0m 1.05ms]
  626.  
  627.  
  628. >> Runtime for discovery module 'sensors': 0.1260 seconds with 50672 bytes
  629. >> SNMP: [2/0.06s] MySQL: [41/0.05s] RRD: [0/0.00s]
  630. #### Unload disco module sensors ####
  631.  
  632. Modules status: Global+ OS+ Device  
  633. #### Load disco module storage ####
  634. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/datadomain udp:HOSTNAME:161 fileSystemSpaceTable[0m]
  635. enterprises.138*.0 = "Eltek"
  636.  
  637. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrStorageEntry[0m]
  638.  
  639. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dskTable[0m]
  640.  
  641. SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '23' AND `storage_type` != 'dsk' [0;33m[][0m 1.24ms]
  642. SQL[[1;33mSELECT * FROM `storage` WHERE `device_id`  = '23' [0;33m[][0m 0.65ms]
  643.  
  644.  
  645. >> Runtime for discovery module 'storage': 0.1150 seconds with 9520 bytes
  646. >> SNMP: [3/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s]
  647. #### Unload disco module storage ####
  648.  
  649. Modules status: Global+ OS+ Device  
  650. #### Load disco module hr-device ####
  651. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrDeviceEntry[0m]
  652.  
  653. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrProcessorEntry[0m]
  654.  
  655. Array
  656. (
  657. )
  658. SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '23' [0;33m[][0m 0.81ms]
  659.  
  660.  
  661. >> Runtime for discovery module 'hr-device': 0.0510 seconds with 3656 bytes
  662. >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
  663. #### Unload disco module hr-device ####
  664.  
  665. Modules status: Global+ OS+ Device  
  666. #### Load disco module discovery-protocols ####
  667.  CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 cdpCache[0m]
  668.  
  669.  
  670.  LLDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 lldpRemTable[0m]
  671.  
  672.  
  673.  OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[23][0m 0.82ms]
  674.  
  675. SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[23][0m 1.21ms]
  676. SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.02ms]
  677.  0 orphaned links deleted
  678.  
  679. >> Runtime for discovery module 'discovery-protocols': 0.0770 seconds with 5000 bytes
  680. >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
  681. #### Unload disco module discovery-protocols ####
  682.  
  683. Modules status: Global+ OS+ Device  
  684. #### Load disco module arp-table ####
  685. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
  686.  
  687. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
  688. ipNetToMediaPhysAddress[1][*] = 0:a:19:d:22:96
  689.  
  690. SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[23,""][0m 5.16ms]
  691. SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[23,1][0m 1.09ms]
  692. Ethernet Interface:
  693. 0:a:19:d:22:96 => 10.0.100.157
  694.  
  695. SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 7.48ms]
  696.  
  697.  
  698. >> Runtime for discovery module 'arp-table': 0.0690 seconds with 15232 bytes
  699. >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s]
  700. #### Unload disco module arp-table ####
  701.  
  702. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  703.  
  704. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  705.  
  706. Modules status: Global+ OS+ Device  
  707. #### Load disco module bgp-peers ####
  708. SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 bgpLocalAs[0m]
  709. "Eltek"
  710.  
  711. No BGP on hostPeers :
  712. SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[23,""][0m 0.58ms]
  713. SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[23,""][0m 0.54ms]
  714.  
  715. SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[23][0m 0.63ms]
  716.  
  717. >> Runtime for discovery module 'bgp-peers': 0.0240 seconds with 5568 bytes
  718. >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
  719. #### Unload disco module bgp-peers ####
  720.  
  721. Modules status: Global+ OS+ Device  
  722. #### Load disco module vlans ####
  723. SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[23][0m 0.75ms]
  724. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
  725.  
  726. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
  727.  
  728.  
  729.  
  730. >> Runtime for discovery module 'vlans': 0.0780 seconds with 9256 bytes
  731. >> SNMP: [2/0.08s] MySQL: [1/0.00s] RRD: [0/0.00s]
  732. #### Unload disco module vlans ####
  733.  
  734. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  735.  
  736. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  737.  
  738. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  739.  
  740. Modules status: Global+ OS+ Device  
  741. #### Load disco module ucd-diskio ####
  742. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 diskIOEntry[0m]
  743.  
  744. Array
  745. (
  746. )
  747. SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id`  = '23' [0;33m[][0m 0.85ms]
  748.  
  749.  
  750. >> Runtime for discovery module 'ucd-diskio': 0.0300 seconds with 3112 bytes
  751. >> SNMP: [1/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
  752. #### Unload disco module ucd-diskio ####
  753.  
  754. Modules status: Global- OS- Device  Module [ applications ] disabled on os.
  755.  
  756. Modules status: Global+ OS+ Device  
  757. #### Load disco module services ####
  758.  
  759. >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes
  760. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  761. #### Unload disco module services ####
  762.  
  763. Modules status: Global+ OS+ Device  
  764. #### Load disco module stp ####
  765. SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[23][0m 0.71ms]
  766. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
  767.  
  768.  
  769.  
  770. >> Runtime for discovery module 'stp': 0.0260 seconds with 5744 bytes
  771. >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
  772. #### Unload disco module stp ####
  773.  
  774. Modules status: Global+ OS+ Device  
  775. #### Load disco module ntp ####
  776.  
  777. >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
  778. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  779. #### Unload disco module ntp ####
  780.  
  781. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  782.  
  783. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  784.  
  785. Modules status: Global+ OS+ Device  
  786. #### Load disco module wireless ####
  787. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ap-count"][0m 1ms]
  788. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"clients"][0m 0.76ms]
  789. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"quality"][0m 0.74ms]
  790. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"capacity"][0m 0.73ms]
  791. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"utilization"][0m 0.74ms]
  792. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"rate"][0m 0.74ms]
  793. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ccq"][0m 0.72ms]
  794. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"snr"][0m 0.75ms]
  795. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ssr"][0m 0.7ms]
  796. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"mse"][0m 0.7ms]
  797. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"rssi"][0m 0.7ms]
  798. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"power"][0m 0.69ms]
  799. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"noise-floor"][0m 0.69ms]
  800. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"errors"][0m 0.7ms]
  801. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"error-ratio"][0m 0.71ms]
  802. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"error-rate"][0m 0.72ms]
  803. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"frequency"][0m 0.73ms]
  804. SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"distance"][0m 0.78ms]
  805.  
  806. >> Runtime for discovery module 'wireless': 0.0210 seconds with 123048 bytes
  807. >> SNMP: [0/0.00s] MySQL: [18/0.02s] RRD: [0/0.00s]
  808. #### Unload disco module wireless ####
  809.  
  810. Modules status: Global+ OS+ Device  
  811. #### Load disco module fdb-table ####
  812. SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[23][0m 0.55ms]
  813. SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[23][0m 0.72ms]
  814. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1qTpFdbPort[0m]
  815.  
  816. SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dTpFdbPort[0m]
  817.  
  818.  
  819.  
  820. >> Runtime for discovery module 'fdb-table': 0.0760 seconds with 19320 bytes
  821. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  822. #### Unload disco module fdb-table ####
  823.  
  824. SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ?  [0;33m[23,"poll_mib"][0m 0.83ms]
  825. SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[2.424,23][0m 2.81ms]
  826. Discovered in 2.424 seconds
  827.  
  828. SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.0.100.157","start":1541439077.101513,"duration":"2.761","devices":1,"poller":"soc-tools"}[0m 2.05ms]
  829. ./discovery.php 10.0.100.157 2018-11-05 11:31:19 - 1 devices discovered in 2.761 secs
  830. SNMP [31/1.00s]: Get[9/0.35s] Getnext[1/0.02s] Walk[21/0.63s]
  831. MySQL [95/0.13s]: Cell[14/0.01s] Row[1/0.00s] Rows[66/0.08s] Column[2/0.00s] Update[3/0.00s] Insert[4/0.01s] Delete[5/0.01s]