- LibreNMS Discovery
- SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.71ms]
- SQL[[1;33mSELECT version() [0;33m[][0m 0.46ms]
- ===================================
- Version info:
- Commit SHA: 4e8acdd894d9a5fb3d03b23a31dfd97f373a9ca0
- Commit Date: 1541405427
- DB Schema: 270
- PHP: 7.2.11
- MySQL: 10.2.18-MariaDB
- RRDTool: 1.6.0
- SNMP: NET-SNMP 5.7.2
- ==================================DEBUG!
- Updating os_def.cache... Done
- SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.0.100.157' ORDER BY device_id DESC [0;33m[][0m 0.7ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[23][0m 0.37ms]
- 10.0.100.157 23 valere [FPING] /usr/sbin/fping -e -q -c 3 -p 500 -t 500 10.0.100.157
- Array
- (
- [xmt] => 3
- [rcv] => 3
- [loss] => 0
- [min] => 0.62
- [max] => 1.38
- [avg] => 0.87
- [exitcode] => 0
- )
- SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.62","max":"1.38","avg":"0.87","device_id":23}[0m 2.45ms]
- SNMP Check response code: 0
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[23,"poll_mib"][0m 0.87ms]
- Attempting to initialize OS: valere
- OS initilized as Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
- .*.*.0 = Eltek Compact Shelf
- .*.*.0 = .*.4.1.13858
- .*.*.0 = Sys Description
- >> Runtime for discovery module 'core': 0.0190 seconds with 984 bytes
- >> SNMP: [2/0.07s] MySQL: [4/0.01s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
- Sys Description
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
- .*.4.1.13858
- | Sys Description | .1.3.6.1.4.1.13858 |
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m]
- OS: Eltek Valere (valere)
- >> Runtime for discovery module 'os': 0.1470 seconds with 1336 bytes
- >> SNMP: [3/0.15s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifDescr[0m]
- ifDescr.1 = Ethernet Interface
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifName[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifAlias[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifType[0m]
- ifType.1 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => Ethernet Interface
- [ifType] => ethernetCsmacd
- )
- )
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[23][0m 1.77ms]
- .
- >> Runtime for discovery module 'ports': 0.0970 seconds with 4152 bytes
- >> SNMP: [4/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '23' [0;33m[][0m 1.03ms]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ifStackStatus[0m]
- >> Runtime for discovery module 'ports-stack': 0.0260 seconds with 1736 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 entPhysicalEntry[0m]
- SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[23][0m 1.26ms]
- >> Runtime for discovery module 'entity-physical': 0.0530 seconds with 5456 bytes
- >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global- OS- Device Module [ entity-state ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrProcessorLoad[0m]
- UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[23][0m 1.39ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[23][0m 0.57ms]
- SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[23][0m 0.59ms]
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m]
- SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[23][0m 0.97ms]
- SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.04ms]
- >> Runtime for discovery module 'processors': 0.0870 seconds with 139520 bytes
- >> SNMP: [2/0.08s] MySQL: [5/0.01s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[23][0m 0.7ms]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrStorageEntry[0m]
- SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '23' [0;33m[][0m 0.98ms]
- >> Runtime for discovery module 'mempools': 0.1140 seconds with 28600 bytes
- >> SNMP: [3/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[23][0m 0.43ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2664 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
- Modules status: Global- OS- Device Module [ vrf ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAdEntIfIndex[0m]
- ipAdEntIfIndex.* 1
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAdEntNetMask.10.0.100.157[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[23,"1"][0m 0.69ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[23,"1"][0m 0.55ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.100.157\/23"][0m 0.94ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.0.100.157\/23"][0m 1ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.0.100.157\/23"][0m 0.9ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["10.0.100.157",23,121][0m 0.66ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.0.100.157",23,121][0m 0.51ms]
- .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[23][0m 3.9ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.0530 seconds with 34328 bytes
- >> SNMP: [2/0.04s] MySQL: [3/0.01s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
- SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[23][0m 0.99ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.0490 seconds with 3384 bytes
- >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS- Device Module [ route ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- Caching data: sensors SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OteQUs -Ih -m VALERE-DC-POWER-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 vpwrSystemParameterGroup[0m]
- vpwrSystemShelfCapacity.0 = 2
- vpwrSystemVoltage.0 = 5408
- vpwrSystemCurrent.0 = 5
- vpwrSystemControllerState.0 = 3
- vpwrSystemInternalTemperature.0 = 27
- vpwrSystemTempCompensationState.0 = 0
- vpwrSystemType.0 = 0
- vpwrSystemParameterGroup.8.0 = 484214900
- vpwrSystemParameterGroup.9.0 = 8
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 entPhysicalDescr[0m]
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[23,"ipmi_hostname"][0m 0.85ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",23,"ipmi"][0m 1.28ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",23,"ipmi"][0m 1.16ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",23,"ipmi"][0m 1.08ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",23,"ipmi"][0m 1.11ms]
- Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",23,"snmp"][0m 1.06ms]
- Current: Dynamic Discovery (current): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => vpwrSystemParameterGroup
- [value] => vpwrSystemCurrent
- [num_oid] => .1.3.6.1.4.1.13858.2.3.3.
- [descr] => System Current
- )
- )
- )
- Data vpwrSystemParameterGroup: Array
- (
- [0] => Array
- (
- [vpwrSystemShelfCapacity] => 2
- [vpwrSystemVoltage] => 5408
- [vpwrSystemCurrent] => 5
- [vpwrSystemControllerState] => 3
- [vpwrSystemInternalTemperature] => 27
- [vpwrSystemTempCompensationState] => 0
- [vpwrSystemType] => 0
- )
- [8.0] => Array
- (
- [vpwrSystemParameterGroup] => 484214900
- )
- [9.0] => Array
- (
- [vpwrSystemParameterGroup] => 8
- )
- )
- Final sensor value: 5
- Cur 5, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1.3.6.1.4.1.13858.2.3.3.0, 0, valere, System Current, snmp, 1, 1, , 5
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",23,"valere","0"][0m 0.86ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",23,"valere","0"][0m 0.92ms]
- .Final sensor value:
- Final sensor value:
- Array
- (
- [valere] => Array
- (
- [0] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",23,"snmp"][0m 1.15ms]
- 0 -> valere
- Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",23,"snmp"][0m 1.11ms]
- Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",23,"snmp"][0m 1.13ms]
- Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",23,"snmp"][0m 1.06ms]
- Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",23,"snmp"][0m 1.24ms]
- Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",23,"snmp"][0m 1.12ms]
- Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",23,"snmp"][0m 1.08ms]
- Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",23,"snmp"][0m 1.1ms]
- Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",23,"snmp"][0m 1.07ms]
- Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",23,"snmp"][0m 1.06ms]
- State: Dynamic Discovery (state): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => vpwrSystemParameterGroup
- [value] => vpwrSystemControllerState
- [num_oid] => .1.3.6.1.4.1.13858.2.3.4.
- [descr] => Controller State
- [state_name] => vpwrSystemControllerState
- [states] => Array
- (
- [0] => Array
- (
- [descr] => systemControllerStateUnknown
- [graph] => 0
- [value] => 0
- [generic] => 3
- )
- [1] => Array
- (
- [descr] => systemControllerStateNormal
- [graph] => 0
- [value] => 1
- [generic] => 0
- )
- [2] => Array
- (
- [descr] => systemControllerStateChange
- [graph] => 0
- [value] => 2
- [generic] => 1
- )
- [3] => Array
- (
- [descr] => systemControllerStateAlarm
- [graph] => 0
- [value] => 3
- [generic] => 2
- )
- [4] => Array
- (
- [descr] => systemControllerStateMenu
- [graph] => 0
- [value] => 4
- [generic] => 1
- )
- [5] => Array
- (
- [descr] => systemControllerStateIrActive
- [graph] => 0
- [value] => 5
- [generic] => 1
- )
- )
- )
- [1] => Array
- (
- [oid] => vpwrSystemParameterGroup
- [value] => vpwrSystemTempCompensationState
- [num_oid] => .1.3.6.1.4.1.13858.2.3.4.
- [descr] => Temperature Compensation State
- [state_name] => vpwrSystemTempCompensationState
- [states] => Array
- (
- [0] => Array
- (
- [descr] => systemTempCompInactive
- [graph] => 0
- [value] => 0
- [generic] => 0
- )
- [1] => Array
- (
- [descr] => systemTempCompActive
- [graph] => 0
- [value] => 1
- [generic] => 1
- )
- )
- )
- )
- )
- Data vpwrSystemParameterGroup: Array
- (
- [0] => Array
- (
- [vpwrSystemShelfCapacity] => 2
- [vpwrSystemVoltage] => 5408
- [vpwrSystemCurrent] => 5
- [vpwrSystemControllerState] => 3
- [vpwrSystemInternalTemperature] => 27
- [vpwrSystemTempCompensationState] => 0
- [vpwrSystemType] => 0
- )
- [8.0] => Array
- (
- [vpwrSystemParameterGroup] => 484214900
- )
- [9.0] => Array
- (
- [vpwrSystemParameterGroup] => 8
- )
- )
- Final sensor value: 3
- Cur 3, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["vpwrSystemControllerState"][0m 0.63ms]
- SQL[[1;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [0;33m[8][0m 0.61ms]
- Discover sensor: .1.3.6.1.4.1.13858.2.3.4.0, 0, vpwrSystemControllerState, Controller State, snmp, 1, 1, , 3
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",23,"vpwrSystemControllerState","0"][0m 0.73ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemControllerState","0"][0m 0.85ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemControllerState","0"][0m 0.73ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["vpwrSystemControllerState"][0m 0.52ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":234,"state_index_id":8}[0m 2.57ms]
- Final sensor value:
- Final sensor value:
- Data vpwrSystemParameterGroup: Array
- (
- [0] => Array
- (
- [vpwrSystemShelfCapacity] => 2
- [vpwrSystemVoltage] => 5408
- [vpwrSystemCurrent] => 5
- [vpwrSystemControllerState] => 3
- [vpwrSystemInternalTemperature] => 27
- [vpwrSystemTempCompensationState] => 0
- [vpwrSystemType] => 0
- )
- [8.0] => Array
- (
- [vpwrSystemParameterGroup] => 484214900
- )
- [9.0] => Array
- (
- [vpwrSystemParameterGroup] => 8
- )
- )
- Final sensor value: 0
- Cur 0, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["vpwrSystemTempCompensationState"][0m 0.54ms]
- SQL[[1;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [0;33m[9][0m 0.62ms]
- Discover sensor: .1.3.6.1.4.1.13858.2.3.4.0, 0, vpwrSystemTempCompensationState, Temperature Compensation State, snmp, 1, 1, , 0
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",23,"vpwrSystemTempCompensationState","0"][0m 0.74ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemTempCompensationState","0"][0m 0.85ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",23,"vpwrSystemTempCompensationState","0"][0m 0.7ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["vpwrSystemTempCompensationState"][0m 0.53ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":235,"state_index_id":9}[0m 2.41ms]
- Final sensor value:
- Final sensor value:
- Array
- (
- [vpwrSystemControllerState] => Array
- (
- [0] => 1
- )
- [vpwrSystemTempCompensationState] => Array
- (
- [0] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",23,"snmp"][0m 1.24ms]
- 0 -> vpwrSystemControllerState
- 0 -> vpwrSystemTempCompensationState
- Temperature: Dynamic Discovery (temperature): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => vpwrSystemParameterGroup
- [value] => vpwrSystemInternalTemperature
- [num_oid] => .1.3.6.1.4.1.13858.2.3.5.
- [descr] => Internal Temperature
- )
- )
- )
- Data vpwrSystemParameterGroup: Array
- (
- [0] => Array
- (
- [vpwrSystemShelfCapacity] => 2
- [vpwrSystemVoltage] => 5408
- [vpwrSystemCurrent] => 5
- [vpwrSystemControllerState] => 3
- [vpwrSystemInternalTemperature] => 27
- [vpwrSystemTempCompensationState] => 0
- [vpwrSystemType] => 0
- )
- [8.0] => Array
- (
- [vpwrSystemParameterGroup] => 484214900
- )
- [9.0] => Array
- (
- [vpwrSystemParameterGroup] => 8
- )
- )
- Final sensor value: 27
- Cur 27, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1.3.6.1.4.1.13858.2.3.5.0, 0, valere, Internal Temperature, snmp, 1, 1, , 27
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",23,"valere","0"][0m 0.82ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",23,"valere","0"][0m 0.91ms]
- .Final sensor value:
- Final sensor value:
- Array
- (
- [valere] => Array
- (
- [0] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",23,"snmp"][0m 1.23ms]
- 0 -> valere
- Voltage: Dynamic Discovery (voltage): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => vpwrSystemParameterGroup
- [value] => vpwrSystemVoltage
- [num_oid] => .1.3.6.1.4.1.13858.2.3.2.
- [descr] => System Voltage
- [divisor] => 100
- )
- )
- )
- Data vpwrSystemParameterGroup: Array
- (
- [0] => Array
- (
- [vpwrSystemShelfCapacity] => 2
- [vpwrSystemVoltage] => 5408
- [vpwrSystemCurrent] => 5
- [vpwrSystemControllerState] => 3
- [vpwrSystemInternalTemperature] => 27
- [vpwrSystemTempCompensationState] => 0
- [vpwrSystemType] => 0
- )
- [8.0] => Array
- (
- [vpwrSystemParameterGroup] => 484214900
- )
- [9.0] => Array
- (
- [vpwrSystemParameterGroup] => 8
- )
- )
- Final sensor value: 5408
- Cur 5408, Low: null, Low Warn: null, Warn: null, High: null
- Discover sensor: .1.3.6.1.4.1.13858.2.3.2.0, 0, valere, System Voltage, snmp, 100, 1, , 54.08
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",23,"valere","0"][0m 0.77ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",23,"valere","0"][0m 0.9ms]
- .Final sensor value:
- Final sensor value:
- Array
- (
- [valere] => Array
- (
- [0] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",23,"snmp"][0m 1.16ms]
- 0 -> valere
- Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",23,"snmp"][0m 1.06ms]
- Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",23,"snmp"][0m 1.05ms]
- Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",23,"snmp"][0m 1.05ms]
- Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",23,"snmp"][0m 1.06ms]
- Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",23,"snmp"][0m 1.06ms]
- Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",23,"snmp"][0m 1.06ms]
- Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",23,"snmp"][0m 1.05ms]
- Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",23,"snmp"][0m 1.08ms]
- Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",23,"snmp"][0m 1.05ms]
- >> Runtime for discovery module 'sensors': 0.1260 seconds with 50672 bytes
- >> SNMP: [2/0.06s] MySQL: [41/0.05s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek:/opt/librenms/mibs/datadomain udp:HOSTNAME:161 fileSystemSpaceTable[0m]
- enterprises.138*.0 = "Eltek"
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrStorageEntry[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dskTable[0m]
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '23' AND `storage_type` != 'dsk' [0;33m[][0m 1.24ms]
- SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '23' [0;33m[][0m 0.65ms]
- >> Runtime for discovery module 'storage': 0.1150 seconds with 9520 bytes
- >> SNMP: [3/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrDeviceEntry[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 hrProcessorEntry[0m]
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '23' [0;33m[][0m 0.81ms]
- >> Runtime for discovery module 'hr-device': 0.0510 seconds with 3656 bytes
- >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 cdpCache[0m]
- LLDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 lldpRemTable[0m]
- OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[23][0m 0.82ms]
- SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[23][0m 1.21ms]
- SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.02ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0770 seconds with 5000 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
- ipNetToMediaPhysAddress[1][*] = 0:a:19:d:22:96
- SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[23,""][0m 5.16ms]
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[23,1][0m 1.09ms]
- Ethernet Interface:
- 0:a:19:d:22:96 => 10.0.100.157
- SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 7.48ms]
- >> Runtime for discovery module 'arp-table': 0.0690 seconds with 15232 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os.
- Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module bgp-peers ####
- SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 bgpLocalAs[0m]
- "Eltek"
- No BGP on hostPeers :
- SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[23,""][0m 0.58ms]
- SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[23,""][0m 0.54ms]
- SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[23][0m 0.63ms]
- >> Runtime for discovery module 'bgp-peers': 0.0240 seconds with 5568 bytes
- >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[23][0m 0.75ms]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
- >> Runtime for discovery module 'vlans': 0.0780 seconds with 9256 bytes
- >> SNMP: [2/0.08s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 diskIOEntry[0m]
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '23' [0;33m[][0m 0.85ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0300 seconds with 3112 bytes
- >> SNMP: [1/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS- Device Module [ applications ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS+ Device
- #### Load disco module stp ####
- SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[23][0m 0.71ms]
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
- >> Runtime for discovery module 'stp': 0.0260 seconds with 5744 bytes
- >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+ OS+ Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
- Modules status: Global- OS- Device Module [ mef ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module wireless ####
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ap-count"][0m 1ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"clients"][0m 0.76ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"quality"][0m 0.74ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"capacity"][0m 0.73ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"utilization"][0m 0.74ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"rate"][0m 0.74ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ccq"][0m 0.72ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"snr"][0m 0.75ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"ssr"][0m 0.7ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"mse"][0m 0.7ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"rssi"][0m 0.7ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"power"][0m 0.69ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"noise-floor"][0m 0.69ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"errors"][0m 0.7ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"error-ratio"][0m 0.71ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"error-rate"][0m 0.72ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"frequency"][0m 0.73ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[23,"distance"][0m 0.78ms]
- >> Runtime for discovery module 'wireless': 0.0210 seconds with 123048 bytes
- >> SNMP: [0/0.00s] MySQL: [18/0.02s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[23][0m 0.55ms]
- SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[23][0m 0.72ms]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1qTpFdbPort[0m]
- SNMP[[0;36m/usr/bin/snmpwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/eltek udp:HOSTNAME:161 dot1dTpFdbPort[0m]
- >> Runtime for discovery module 'fdb-table': 0.0760 seconds with 19320 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[23,"poll_mib"][0m 0.83ms]
- SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[2.424,23][0m 2.81ms]
- Discovered in 2.424 seconds
- SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.0.100.157","start":1541439077.101513,"duration":"2.761","devices":1,"poller":"soc-tools"}[0m 2.05ms]
- ./discovery.php 10.0.100.157 2018-11-05 11:31:19 - 1 devices discovered in 2.761 secs
- SNMP [31/1.00s]: Get[9/0.35s] Getnext[1/0.02s] Walk[21/0.63s]
- MySQL [95/0.13s]: Cell[14/0.01s] Row[1/0.00s] Rows[66/0.08s] Column[2/0.00s] Update[3/0.00s] Insert[4/0.01s] Delete[5/0.01s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]