- LibreNMS Discovery
- SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 0.32ms]
- SQL[[1;33mselect count(*) as aggregate from `migrations` limit 1 [0;33m[][0m 0.19ms]
- SQL[[1;33mSELECT version() [0;33m[][0m 0.24ms]
- ===================================
- Version info:
- Commit SHA: 21192a9cf2a3226e1a06bf69e5688242c5903dfa
- Commit Date: 1549635449
- DB Schema: 2019_01_16_195644_add_vrf_id_and_bgpLocalAs (131)
- PHP: 7.0.33-0ubuntu0.16.04.1
- MySQL: 10.0.38-MariaDB-0ubuntu0.16.04.1
- RRDTool: 1.5.5
- SNMP: NET-SNMP 5.7.3
- ==================================DEBUG!
- Updating os_def.cache... Done
- SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '192.168.0.121' ORDER BY device_id DESC [0;33m[][0m 1.85ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[259][0m 0.49ms]
- 192.168.0.121 259 drac [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 192.168.0.121
- Array
- (
- [xmt] => 3
- [rcv] => 3
- [loss] => 0
- [min] => 2.02
- [max] => 2.28
- [avg] => 2.17
- [exitcode] => 0
- )
- SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"2.02","max":"2.28","avg":"2.17","device_id":259,"debug":"[]"}[0m 4.26ms]
- SNMP Check response code: 0
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[259,"poll_mib"][0m 0.34ms]
- MIB: registering
- Attempting to initialize OS: drac
- OS initialized as Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0'[0m]
- .*.*.0 = iDRAC-DPJ115J
- .*.*.0 = .*.4.1.674.10892.2
- .*.*.0 = Linux iDRAC-DPJ115J 2.6.24-ami #1 Wed Jul 12 15:31:56 UTC 2017 armv5tejl
- >> Runtime for discovery module 'core': 0.0100 seconds with 1088 bytes
- >> SNMP: [2/0.02s] MySQL: [4/0.01s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysDescr.0'[0m]
- Linux iDRAC-DPJ115J 2.6.24-ami #1 Wed Jul 12 15:31:56 UTC 2017 armv5tejl
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'[0m]
- .*.4.1.674.10892.2
- | Linux iDRAC-DPJ115J 2.6.24-ami #1 Wed Jul 12 15:31:56 UTC 2017 armv5tejl | .1.3.6.1.4.1.674.10892.2 |
- OS: Dell DRAC (drac)
- >> Runtime for discovery module 'os': 0.0180 seconds with 1384 bytes
- >> SNMP: [2/0.02s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ifDescr'[0m]
- ifDescr.1 = lo
- ifDescr.2 = eth1
- ifDescr.3 = eth0
- ifDescr.4 = ncsi-eth2
- ifDescr.5 = ip6tnl0
- ifDescr.6 = eth1.4003
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ifName'[0m]
- ifName = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ifAlias'[0m]
- ifAlias = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ifType'[0m]
- ifType.1 = softwareLoopback
- ifType.2 = ethernetCsmacd
- ifType.3 = ethernetCsmacd
- ifType.4 = ethernetCsmacd
- ifType.5 = tunnel
- ifType.6 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => lo
- [ifType] => softwareLoopback
- )
- [2] => Array
- (
- [ifDescr] => eth1
- [ifType] => ethernetCsmacd
- )
- [3] => Array
- (
- [ifDescr] => eth0
- [ifType] => ethernetCsmacd
- )
- [4] => Array
- (
- [ifDescr] => ncsi-eth2
- [ifType] => ethernetCsmacd
- )
- [5] => Array
- (
- [ifDescr] => ip6tnl0
- [ifType] => tunnel
- )
- [6] => Array
- (
- [ifDescr] => eth1.4003
- [ifType] => ethernetCsmacd
- )
- )
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[259][0m 1.31ms]
- Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["lo","softwareLoopback",1,"lo","lo",12548][0m 5.2ms]
- . Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["eth1","ethernetCsmacd",2,"eth1","eth1",12549][0m 6.86ms]
- . Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["eth0","ethernetCsmacd",3,"eth0","eth0",12550][0m 6.62ms]
- . Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["ncsi-eth2","ethernetCsmacd",4,"ncsi-eth2","ncsi-eth2",12551][0m 7.47ms]
- . Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["ip6tnl0","tunnel",5,"ip6tnl0","ip6tnl0",12552][0m 7.81ms]
- . Using ifDescr as ifAlias Using ifDescr as ifNameSQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["eth1.4003","ethernetCsmacd",6,"eth1.4003","eth1.4003",12553][0m 8.13ms]
- .
- >> Runtime for discovery module 'ports': 0.1410 seconds with 4736 bytes
- >> SNMP: [4/0.09s] MySQL: [7/0.04s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '259' [0;33m[][0m 0.59ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ifStackStatus'[0m]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.0270 seconds with 1736 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m]
- entPhysicalEntry = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[259][0m 0.78ms]
- >> Runtime for discovery module 'entity-physical': 0.0460 seconds with 5456 bytes
- >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-state ####
- SQL[[1;33mSELECT entPhysical_id, entPhysicalIndex FROM entPhysical WHERE device_id=? [0;33m[259][0m 0.48ms]
- >> Runtime for discovery module 'entity-state': 0.0000 seconds with 2056 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module entity-state ####
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hrProcessorLoad'[0m]
- hrProcessorLoad = No Such Object available on this agent at this OID
- UCD Resources: SQL[[1;33mSELECT `devices`.*, `location`, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.location_id=`locations`.`id` WHERE `device_id` = ? [0;33m[259][0m 0.63ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[259][0m 0.28ms]
- SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[259][0m 0.22ms]
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'[0m]
- No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[259][0m 0.47ms]
- SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.94ms]
- >> Runtime for discovery module 'processors': 0.0400 seconds with 66472 bytes
- >> SNMP: [2/0.04s] MySQL: [5/0.00s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[259][0m 0.49ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hpLocal'[0m]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hpGlobal'[0m]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hrStorageEntry'[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '259' [0;33m[][0m 0.52ms]
- >> Runtime for discovery module 'mempools': 0.0870 seconds with 28752 bytes
- >> SNMP: [3/0.08s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[259][0m 0.65ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2624 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-mac-accounting ####
- >> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds with 1064 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-mac-accounting ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-pw ####
- >> Runtime for discovery module 'cisco-pw': 0.0000 seconds with 1344 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-pw ####
- Modules status: Global+ OS+ Device
- #### Load disco module vrf ####
- SQL[[1;33mSELECT * FROM ports WHERE device_id = '259' [0;33m[][0m 0.77ms]
- SQL[[1;33mSELECT * FROM vrfs WHERE device_id = '259' [0;33m[][0m 0.51ms]
- >> Runtime for discovery module 'vrf': 0.0010 seconds with 9760 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module vrf ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-cef ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'CISCO-CEF-MIB::cefSwitchingPath'[0m]
- cefSwitchingPath = No Such Object available on this agent at this OID
- cefSwitchingPath = No Such Object available on this agent at this OID || cefSwitchingPath || || ||
- Array
- (
- )
- Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m]
- entPhysicalDescr = No Such Object available on this agent at this OID
- entPhysicalNameSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'entPhysicalName'[0m]
- entPhysicalName = No Such Object available on this agent at this OID
- entPhysicalModelNameSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'entPhysicalModelName'[0m]
- entPhysicalModelName = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'cisco-cef': 0.1230 seconds with 2792 bytes
- >> SNMP: [3/0.10s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-cef ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-sla ####
- >> Runtime for discovery module 'cisco-sla': 0.0000 seconds with 1616 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-sla ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-cbqos ####
- >> Runtime for discovery module 'cisco-cbqos': 0.0000 seconds with 2728 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-cbqos ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-otv ####
- >> Runtime for discovery module 'cisco-otv': 0.0000 seconds with 4224 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-otv ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m]
- ipAdEntIfIndex.* 1
- ipAdEntIfIndex.* 6
- ipAdEntIfIndex.* 3
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipAdEntNetMask.127.0.0.1'[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[259,"1"][0m 0.43ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[259,"1"][0m 0.48ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/8"][0m 1.18ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"127.0.0.1\/8"][0m 6.06ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/8"][0m 0.62ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["127.0.0.1",8,12548][0m 0.39ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"127.0.0.1",8,12548][0m 4.44ms]
- .SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipAdEntNetMask.169.254.31.1'[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[259,"6"][0m 0.49ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[259,"6"][0m 0.48ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.31.1\/16"][0m 0.89ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"169.254.31.1\/16"][0m 9.52ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.31.1\/16"][0m 1.32ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["169.254.31.1",16,12553][0m 0.42ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"169.254.31.1",16,12553][0m 6.27ms]
- .SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipAdEntNetMask.192.168.0.121'[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[259,"3"][0m 0.55ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[259,"3"][0m 0.3ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["192.168.0.121\/24"][0m 0.98ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"192.168.0.121\/24"][0m 9.03ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["192.168.0.121\/24"][0m 0.92ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["192.168.0.121",24,12550][0m 0.51ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"192.168.0.121",24,12550][0m 6.71ms]
- .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[259][0m 23.56ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.1630 seconds with 34384 bytes
- >> SNMP: [4/0.08s] MySQL: [7/0.07s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'[0m]
- ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[259][0m 0.65ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.0470 seconds with 3272 bytes
- >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module route ####
- >> Runtime for discovery module 'route': 0.0000 seconds with 1336 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module route ####
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- Caching data: sensors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'DELL-RAC-MIB:IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'drsGlobalSystemStatus'[0m]
- drsGlobalSystemStatus.0 = 3
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'DELL-RAC-MIB:IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'systemStateIDSDMCardUnitStatusCombined'[0m]
- systemStateIDSDMCardUnitStatusCombined = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'DELL-RAC-MIB:IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'systemStateIDSDMCardDeviceStatusCombined'[0m]
- systemStateIDSDMCardDeviceStatusCombined = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'DELL-RAC-MIB:IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'intrusionStatus'[0m]
- intrusionStatus = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'DELL-RAC-MIB:IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'intrusionReading'[0m]
- intrusionReading = No Such Object available on this agent at this OID
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescr
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[259,"ipmi_hostname"][0m 0.89ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",259,"ipmi"][0m 0.85ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",259,"ipmi"][0m 0.63ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",259,"ipmi"][0m 0.63ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",259,"ipmi"][0m 0.75ms]
- Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",259,"snmp"][0m 0.71ms]
- Current: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",259,"snmp"][0m 0.79ms]
- Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",259,"snmp"][0m 0.67ms]
- Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",259,"snmp"][0m 1.03ms]
- Fanspeed: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'coolingDevicechassisIndex.1'[0m]
- .*.4.1.674.108**.1 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",259,"snmp"][0m 0.9ms]
- Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",259,"snmp"][0m 0.73ms]
- Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",259,"snmp"][0m 0.88ms]
- Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",259,"snmp"][0m 0.72ms]
- Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",259,"snmp"][0m 0.55ms]
- Power_consumed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",259,"snmp"][0m 0.6ms]
- Power_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",259,"snmp"][0m 0.73ms]
- Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",259,"snmp"][0m 0.6ms]
- Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",259,"snmp"][0m 0.54ms]
- State: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'virtualDiskTable'[0m]
- virtualDiskTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'processorDeviceTable'[0m]
- processorDeviceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'memoryDeviceTable'[0m]
- memoryDeviceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'voltageProbeTable'[0m]
- voltageProbeTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'amperageProbeTable'[0m]
- amperageProbeTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUse' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'systemBatteryTable'[0m]
- systemBatteryTable = No Such Object available on this agent at this OID
- Dynamic Discovery (state): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => drsGlobalSystemStatus
- [value] => drsGlobalSystemStatus
- [num_oid] => .1.3.6.1.4.1.674.10892.2.2.1.{{ $index }}
- [descr] => Global System Status
- [index] => drsGlobalSystemStatus.{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [descr] => other
- [graph] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [value] => 2
- [descr] => unknown
- [graph] => 1
- [generic] => 3
- )
- [2] => Array
- (
- [value] => 3
- [descr] => ok
- [graph] => 1
- [generic] => 0
- )
- [3] => Array
- (
- [value] => 4
- [descr] => nonCritical
- [graph] => 1
- [generic] => 1
- )
- [4] => Array
- (
- [value] => 5
- [descr] => critical
- [graph] => 1
- [generic] => 2
- )
- [5] => Array
- (
- [value] => 6
- [descr] => nonRecoverable
- [graph] => 1
- [generic] => 2
- )
- )
- )
- [1] => Array
- (
- [oid] => systemStateIDSDMCardUnitStatusCombined
- [value] => systemStateIDSDMCardUnitStatusCombined
- [num_oid] => .1.3.6.1.4.1.674.10892.5.4.200.10.1.58.{{ $index }}
- [descr] => IDSDM Card Unit Combined Status
- [index] => systemStateIDSDMCardUnitStatusCombined.{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [descr] => other
- [graph] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [value] => 2
- [descr] => unknown
- [graph] => 1
- [generic] => 3
- )
- [2] => Array
- (
- [value] => 3
- [descr] => ok
- [graph] => 1
- [generic] => 0
- )
- [3] => Array
- (
- [value] => 4
- [descr] => nonCritical
- [graph] => 1
- [generic] => 1
- )
- [4] => Array
- (
- [value] => 5
- [descr] => critical
- [graph] => 1
- [generic] => 2
- )
- [5] => Array
- (
- [value] => 6
- [descr] => nonRecoverable
- [graph] => 1
- [generic] => 2
- )
- )
- )
- [2] => Array
- (
- [oid] => systemStateIDSDMCardDeviceStatusCombined
- [value] => systemStateIDSDMCardDeviceStatusCombined
- [num_oid] => .1.3.6.1.4.1.674.10892.5.4.200.10.1.60.{{ $index }}
- [descr] => IDSDM Card Device Combined Status
- [index] => systemStateIDSDMCardDeviceStatusCombined.{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [descr] => other
- [graph] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [value] => 2
- [descr] => unknown
- [graph] => 1
- [generic] => 3
- )
- [2] => Array
- (
- [value] => 3
- [descr] => ok
- [graph] => 1
- [generic] => 0
- )
- [3] => Array
- (
- [value] => 4
- [descr] => nonCritical
- [graph] => 1
- [generic] => 1
- )
- [4] => Array
- (
- [value] => 5
- [descr] => critical
- [graph] => 1
- [generic] => 2
- )
- [5] => Array
- (
- [value] => 6
- [descr] => nonRecoverable
- [graph] => 1
- [generic] => 2
- )
- )
- )
- [3] => Array
- (
- [oid] => intrusionStatus
- [value] => intrusionStatus
- [num_oid] => .1.3.6.1.4.1.674.10892.5.4.300.70.1.5.{{ $index }}
- [descr] => Intrusion Status
- [index] => intrusionStatus.{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [descr] => other
- [graph] => 1
- [generic] => 3
- )
- [1] => Array
- (
- [value] => 2
- [descr] => unknown
- [graph] => 1
- [generic] => 3
- )
- [2] => Array
- (
- [value] => 3
- [descr] => ok
- [graph] => 1
- [generic] => 0
- )
- [3] => Array
- (
- [value] => 4
- [descr] => nonCritical
- [graph] => 1
- [generic] => 1
- )
- [4] => Array
- (
- [value] => 5
- [descr] => critical
- [graph] => 1
- [generic] => 2
- )
- [5] => Array
- (
- [value] => 6
- [descr] => nonRecoverable
- [graph] => 1
- [generic] => 2
- )
- )
- )
- [4] => Array
- (
- [oid] => intrusionReading
- [value] => intrusionReading
- [num_oid] => .1.3.6.1.4.1.674.10892.5.4.300.70.1.6.{{ $index }}
- [descr] => Intrusion Reading
- [index] => intrusionReading.{{ $index }}
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [descr] => chassisNotBreached
- [graph] => 1
- [generic] => 0
- )
- [1] => Array
- (
- [value] => 2
- [descr] => chassisBreached
- [graph] => 1
- [generic] => 2
- )
- [2] => Array
- (
- [value] => 3
- [descr] => chassisBreachedPrior
- [graph] => 1
- [generic] => 1
- )
- [3] => Array
- (
- [value] => 4
- [descr] => chassisBreachSensorFailure
- [graph] => 1
- [generic] => 1
- )
- )
- )
- )
- )
- Data drsGlobalSystemStatus: Array
- (
- [0] => Array
- (
- [drsGlobalSystemStatus] => 3
- )
- )
- Final sensor value: 3
- Cur 3, Low: null, Low Warn: null, Warn: null, High: null
- SQL[[1;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 [0;33m["drsGlobalSystemStatus"][0m 2.48ms]
- SQL[[1;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [0;33m[43][0m 0.58ms]
- Discover sensor: .1.3.6.1.4.1.674.10892.2.2.1.0, drsGlobalSystemStatus.0, drsGlobalSystemStatus, Global System Status, snmp, 1, 1, , 3
- SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",259,"drsGlobalSystemStatus","drsGlobalSystemStatus.0"][0m 0.59ms]
- SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",259,"drsGlobalSystemStatus","drsGlobalSystemStatus.0"][0m 0.58ms]
- .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",259,"drsGlobalSystemStatus","drsGlobalSystemStatus.0"][0m 0.41ms]
- SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["drsGlobalSystemStatus"][0m 0.3ms]
- SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":1514,"state_index_id":43}[0m 4.84ms]
- Data systemStateIDSDMCardUnitStatusCombined: Array
- (
- )
- Data systemStateIDSDMCardDeviceStatusCombined: Array
- (
- )
- Data intrusionStatus: Array
- (
- )
- Data intrusionReading: Array
- (
- )
- Array
- (
- [drsGlobalSystemStatus] => Array
- (
- [drsGlobalSystemStatus.0] => 1
- )
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",259,"snmp"][0m 0.93ms]
- drsGlobalSystemStatus.0 -> drsGlobalSystemStatus
- Count: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",259,"snmp"][0m 0.61ms]
- Temperature: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'temperatureProbeStatus'[0m]
- .*.4.1.674.108** No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",259,"snmp"][0m 1.47ms]
- Voltage: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'IDRAC-MIB-SMIv2' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'powerSupplyIndex.1'[0m]
- .*.4.1.674.108**.1 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",259,"snmp"][0m 0.88ms]
- Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",259,"snmp"][0m 0.66ms]
- Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",259,"snmp"][0m 0.69ms]
- Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",259,"snmp"][0m 0.67ms]
- Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",259,"snmp"][0m 0.68ms]
- Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",259,"snmp"][0m 0.73ms]
- Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",259,"snmp"][0m 0.64ms]
- Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",259,"snmp"][0m 0.82ms]
- Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",259,"snmp"][0m 0.78ms]
- Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",259,"snmp"][0m 0.86ms]
- >> Runtime for discovery module 'sensors': 0.3760 seconds with 47464 bytes
- >> SNMP: [14/0.33s] MySQL: [36/0.03s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell:/opt/librenms/mibs/datadomain' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m]
- fileSystemSpaceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hrStorageEntry'[0m]
- hrStorageEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dskTable'[0m]
- dskTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '259' AND `storage_type` != 'dsk' [0;33m[][0m 0.65ms]
- SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '259' [0;33m[][0m 0.54ms]
- >> Runtime for discovery module 'storage': 0.0770 seconds with 8992 bytes
- >> SNMP: [3/0.07s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m]
- hrDeviceEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m]
- hrProcessorEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '259' [0;33m[][0m 0.65ms]
- >> Runtime for discovery module 'hr-device': 0.0580 seconds with 3704 bytes
- >> SNMP: [2/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'cdpCache'[0m]
- cdpCache = No Such Object available on this agent at this OID
- LLDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'lldpRemTable'[0m]
- lldpRemTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[259][0m 0.94ms]
- SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.11ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0610 seconds with 5112 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipNetToPhysicalPhysAddress'[0m]
- ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'ipNetToMediaPhysAddress'[0m]
- ipNetToMediaPhysAddress[1][*] = 84:2b:2b:6b:89:2c
- ipNetToMediaPhysAddress[1][*] = 68:b5:99:1b:62:40
- ipNetToMediaPhysAddress[1][*] = 0:15:5d:46:7:2e
- SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[259,""][0m 8.84ms]
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[259,1][0m 2.58ms]
- lo:
- 84:2b:2b:6b:89:2c => 169.254.31.40
- 68:b5:99:1b:62:40 => 192.168.0.101
- 0:15:5d:46:7:2e => 192.168.0.199
- SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 12.96ms]
- >> Runtime for discovery module 'arp-table': 0.0680 seconds with 15440 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.02s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-arp ####
- SQL[[1;33m
- SELECT *
- FROM ipv4_mac as m, ports as i
- WHERE m.port_id = i.port_id
- AND i.device_id = ?
- AND i.deleted = 0
- AND NOT EXISTS (
- SELECT * FROM ipv4_addresses a
- WHERE a.ipv4_address = m.ipv4_address
- )
- GROUP BY ipv4_address
- ORDER BY ipv4_address
- [0;33m[259][0m 8.76ms]
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 81
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 82
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
- SQL[[1;33mSELECT `devices`.*, `location`, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.location_id=`locations`.`id` WHERE `device_id` = ? [0;33m[null][0m 0.68ms]
- SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[null][0m 0.28ms]
- No OS to load
- SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[null][0m 0.29ms]
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 100
- x
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 81
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 82
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
- Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 100
- Warning: array_key_exists() expects parameter 2 to be array, null given in /opt/librenms/includes/common.php on line 1008
- +
- discovering 192.168.0.199
- Discovery by IP disabled, skipping 192.168.0.199SQL[[1;33mINSERT IGNORE INTO `eventlog` (`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:device_id,:reference,:type,:datetime,:severity,:message,:username) [0;33m{"device_id":259,"reference":null,"type":"discovery","datetime":"2019-02-21 10:39:20","severity":4,"message":"ARP discovery of 192.168.0.199 failed - Discovery by IP disabled","username":""}[0m 8.32ms]
- >> Runtime for discovery module 'discovery-arp': 0.0430 seconds with 2137296 bytes
- >> SNMP: [0/0.00s] MySQL: [5/0.02s] RRD: [0/0.00s]
- #### Unload disco module discovery-arp ####
- Modules status: Global+ OS+ Device
- #### Load disco module junose-atm-vp ####
- >> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds with 520 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module junose-atm-vp ####
- Modules status: Global+ OS+ Device
- #### Load disco module bgp-peers ####
- SNMP[[0;36m'/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-Oqvn' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m]
- 0:0:00:00.00
- No BGP on hostPeers :
- SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[259,""][0m 1.41ms]
- SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[259,""][0m 0.52ms]
- SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[259][0m 0.37ms]
- >> Runtime for discovery module 'bgp-peers': 0.0130 seconds with 6344 bytes
- >> SNMP: [1/0.01s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[259][0m 0.59ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.0600 seconds with 9184 bytes
- >> SNMP: [2/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'diskIOEntry'[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '259' [0;33m[][0m 0.51ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0160 seconds with 3160 bytes
- >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global+ OS+ Device
- #### Load disco module applications ####
- Applications: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'nsExtendStatus'[0m]
- nsExtendStatus = No Such Object available on this agent at this OID
- Available:
- Checking for:
- SQL[[1;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`=? ORDER BY `app_type` [0;33m[259][0m 4.61ms]
- SQL[[1;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL [0;33m[][0m 0.88ms]
- >> Runtime for discovery module 'applications': 0.0200 seconds with 4464 bytes
- >> SNMP: [1/0.01s] MySQL: [2/0.01s] RRD: [0/0.00s]
- #### Unload disco module applications ####
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 256 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS+ Device
- #### Load disco module stp ####
- SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[259][0m 0.48ms]
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dot1dStpProtocolSpecification.0'[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0140 seconds with 5752 bytes
- >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+ OS+ Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global+ OS+ Device
- #### Load disco module loadbalancers ####
- >> Runtime for discovery module 'loadbalancers': 3.9100 seconds with 240 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module loadbalancers ####
- Modules status: Global+ OS+ Device
- #### Load disco module mef ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'MEF-UNI-EVC-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'MefServiceEvcCfgEntry'[0m]
- mefServiceEvcCfgEntry = No Such Object available on this agent at this OID
- MEF :
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/mef.inc.php on line 20
- SQL[[1;33mSELECT id, mefID, mefIdent FROM mefinfo WHERE device_id = '259' [0;33m[][0m 0.52ms]
- >> Runtime for discovery module 'mef': 0.0290 seconds with 3472 bytes
- >> SNMP: [1/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module mef ####
- Modules status: Global+ OS+ Device
- #### Load disco module wireless ####
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"ap-count"][0m 0.67ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"clients"][0m 0.44ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"quality"][0m 0.49ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"capacity"][0m 0.43ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"utilization"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"rate"][0m 0.43ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"ccq"][0m 0.37ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"snr"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"ssr"][0m 0.43ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"mse"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"xpi"][0m 0.63ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"rssi"][0m 0.38ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"power"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"noise-floor"][0m 0.42ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"errors"][0m 0.32ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"error-ratio"][0m 0.4ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"error-rate"][0m 0.35ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"frequency"][0m 0.35ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[259,"distance"][0m 0.33ms]
- >> Runtime for discovery module 'wireless': 0.0120 seconds with 191144 bytes
- >> SNMP: [0/0.00s] MySQL: [19/0.01s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[259][0m 0.3ms]
- SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[259][0m 0.41ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-t' '1' '-r' '2' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.0670 seconds with 3008 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[259,"poll_mib"][0m 0.29ms]
- SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[259,"poll_mib"][0m 0.23ms]
- MIB: registering
- SNMP[[0;36m'/usr/bin/snmptranslate' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/drac:/opt/librenms/mibs/dell' '-IR' '-m' 'all' '.1.3.6.1.4.1.674.10892.2'[0m]
- Unknown object identifier: .1.3.6.1.4.1.674.10892.2
- This doesn't look like a MIB:
- MIB: Could not find all::.1.3.6.1.4.1.674.10892.2
- SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[3.089,259][0m 7.1ms]
- Discovered in 3.089 seconds
- SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"192.168.0.121","start":1550745558.3118,"duration":"3.264","devices":1,"poller":"UBUNTU-MONITOR"}[0m 12.39ms]
- ./discovery.php 192.168.0.121 2019-02-21 10:39:21 - 1 devices discovered in 3.264 secs
- SNMP [49/1.12s]: Get[10/0.14s] Getnext[1/0.01s] Walk[38/0.97s]
- MySQL [112/0.25s]: Cell[19/0.02s] Row[-8/-0.01s] Rows[76/0.10s] Column[2/0.00s] Update[13/0.09s] Insert[4/0.03s] Delete[6/0.02s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]