- LibreNMS Discovery
- SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 1.96ms]
- SQL[[1;33mselect count(*) as aggregate from `migrations` limit 1 [0;33m[][0m 2.28ms]
- SQL[[1;33mselect version() [0;33m[][0m 2.19ms]
- ===================================
- Version info:
- Commit SHA:
- Commit Date:
- DB Schema: 2021_25_01_0129_isis_adjacencies_nullable (224)
- PHP: 7.4.25
- MySQL: 10.3.29-MariaDB
- RRDTool: 1.7.2
- SNMP: NET-SNMP 5.9
- ==================================DEBUG!
- Updating os_def.cache
- SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE 'swzolder.high.local' ORDER BY device_id DESC [0;33m[][0m 3.85ms]
- SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[14][0m 2.12ms]
- SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[14][0m 2.12ms]
- swzolder.high.local 14 edgeswitch [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' 'swzolder.high.local'
- response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 2.17/4.53/7.58
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'[0m]
- SNMPv2-MIB::sysObjectID.0 = NET-SNMP-MIB::netSnmpAgentOIDs.10
- Modules status: Global+
- OS
- Device
- #### Load disco module core ####
- Attempting to initialize OS: edgeswitch
- OS initialized: LibreNMS\OS\Edgeswitch
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0'[0m]
- .*.*.0 = .*.4.1.8*
- .*.*.0 = Linux UBNT 3.18.24 #0 Thu Aug 30 12:10:54 2018 mips
- .*.*.0 = USW-16P
- | Linux UBNT 3.18.24 #0 Thu Aug 30 12:10:54 2018 mips | .1.3.6.1.4.1.8072.3.2.10 |
- OS: EdgeSwitch (edgeswitch)
- Attempting to initialize OS: edgeswitch
- OS initialized: LibreNMS\OS\Edgeswitch
- >> Runtime for discovery module 'core': 0.0850 seconds with 15352 bytes
- >> [0;36mSNMP[0m: [1/0.06s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+
- OS
- Device
- #### Load disco module os ####
- Yaml location data:
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'[0m]
- Default
- SQL[[1;33mselect * from `locations` where (`location` = ?) limit 1 [0;33m["Default"][0m 3.31ms]
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'sysContact.0'[0m]
- Default
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ENTITY-MIB::entPhysicalSerialNum.1'[0m]
- ENTITY-MIB::entPhysicalSerialNum.1 = No Such Object available on this agent at this OID
- Yaml OS data:
- Location: Default
- Hardware:
- OS Version:
- OS Features:
- Serial:
- >> Runtime for discovery module 'os': 0.1580 seconds with 288216 bytes
- >> [0;36mSNMP[0m: [4/0.12s] [1;33mMySQL[0m: [1/0.03s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifDescr'[0m]
- ifDescr.1 = Port 1
- ifDescr.2 = Port 2
- ifDescr.3 = Port 3
- ifDescr.4 = Port 4
- ifDescr.5 = Port 5
- ifDescr.6 = Port 6
- ifDescr.7 = Port 7
- ifDescr.8 = Port 8
- ifDescr.9 = Port 9
- ifDescr.10 = Port 10
- ifDescr.11 = Port 11
- ifDescr.12 = Port 12
- ifDescr.13 = Port 13
- ifDescr.14 = Port 14
- ifDescr.15 = Port 15
- ifDescr.16 = Port 16
- ifDescr.17 = Port 17
- ifDescr.18 = Port 18
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifName'[0m]
- ifName.1 = 0/1
- ifName.2 = 0/2
- ifName.3 = 0/3
- ifName.4 = 0/4
- ifName.5 = 0/5
- ifName.6 = 0/6
- ifName.7 = 0/7
- ifName.8 = 0/8
- ifName.9 = 0/9
- ifName.10 = 0/10
- ifName.11 = 0/11
- ifName.12 = 0/12
- ifName.13 = 0/13
- ifName.14 = 0/14
- ifName.15 = 0/15
- ifName.16 = 0/16
- ifName.17 = 0/17
- ifName.18 = 0/18
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifAlias'[0m]
- ifAlias.1 = Uplink Voorzolder
- ifAlias.2 = CK2
- ifAlias.3 = iSCSI switch
- ifAlias.4 = Solaredge
- ifAlias.5 = Atlas
- ifAlias.6 = Port 6
- ifAlias.7 = NAS MGMT
- ifAlias.8 = Port 8
- ifAlias.9 = ESX2 MGMT
- ifAlias.10 = Port 10
- ifAlias.11 = ESX1 MGMT
- ifAlias.12 = Port 12
- ifAlias.13 = Pi-Zolder
- ifAlias.14 = Port 14
- ifAlias.15 = MOXA
- ifAlias.16 = LTE_Backup
- ifAlias.17 = SFP 1
- ifAlias.18 = SFP 2
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifType'[0m]
- ifType.1 = ethernetCsmacd
- ifType.2 = ethernetCsmacd
- ifType.3 = ethernetCsmacd
- ifType.4 = ethernetCsmacd
- ifType.5 = ethernetCsmacd
- ifType.6 = ethernetCsmacd
- ifType.7 = ethernetCsmacd
- ifType.8 = ethernetCsmacd
- ifType.9 = ethernetCsmacd
- ifType.10 = ethernetCsmacd
- ifType.11 = ethernetCsmacd
- ifType.12 = ethernetCsmacd
- ifType.13 = ethernetCsmacd
- ifType.14 = ethernetCsmacd
- ifType.15 = ethernetCsmacd
- ifType.16 = ethernetCsmacd
- ifType.17 = ethernetCsmacd
- ifType.18 = ethernetCsmacd
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifOperStatus'[0m]
- ifOperStatus.1 = up
- ifOperStatus.2 = up
- ifOperStatus.3 = up
- ifOperStatus.4 = up
- ifOperStatus.5 = up
- ifOperStatus.6 = down
- ifOperStatus.7 = up
- ifOperStatus.8 = down
- ifOperStatus.9 = down
- ifOperStatus.10 = down
- ifOperStatus.11 = up
- ifOperStatus.12 = down
- ifOperStatus.13 = down
- ifOperStatus.14 = down
- ifOperStatus.15 = up
- ifOperStatus.16 = down
- ifOperStatus.17 = down
- ifOperStatus.18 = down
- array (
- 1 =>
- array (
- 'ifDescr' => 'Port 1',
- 'ifName' => '0/1',
- 'ifAlias' => 'Uplink Voorzolder',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 2 =>
- array (
- 'ifDescr' => 'Port 2',
- 'ifName' => '0/2',
- 'ifAlias' => 'CK2',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 3 =>
- array (
- 'ifDescr' => 'Port 3',
- 'ifName' => '0/3',
- 'ifAlias' => 'iSCSI switch',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 4 =>
- array (
- 'ifDescr' => 'Port 4',
- 'ifName' => '0/4',
- 'ifAlias' => 'Solaredge',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 5 =>
- array (
- 'ifDescr' => 'Port 5',
- 'ifName' => '0/5',
- 'ifAlias' => 'Atlas',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 6 =>
- array (
- 'ifDescr' => 'Port 6',
- 'ifName' => '0/6',
- 'ifAlias' => 'Port 6',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 7 =>
- array (
- 'ifDescr' => 'Port 7',
- 'ifName' => '0/7',
- 'ifAlias' => 'NAS MGMT',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 8 =>
- array (
- 'ifDescr' => 'Port 8',
- 'ifName' => '0/8',
- 'ifAlias' => 'Port 8',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 9 =>
- array (
- 'ifDescr' => 'Port 9',
- 'ifName' => '0/9',
- 'ifAlias' => 'ESX2 MGMT',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 10 =>
- array (
- 'ifDescr' => 'Port 10',
- 'ifName' => '0/10',
- 'ifAlias' => 'Port 10',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 11 =>
- array (
- 'ifDescr' => 'Port 11',
- 'ifName' => '0/11',
- 'ifAlias' => 'ESX1 MGMT',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 12 =>
- array (
- 'ifDescr' => 'Port 12',
- 'ifName' => '0/12',
- 'ifAlias' => 'Port 12',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 13 =>
- array (
- 'ifDescr' => 'Port 13',
- 'ifName' => '0/13',
- 'ifAlias' => 'Pi-Zolder',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 14 =>
- array (
- 'ifDescr' => 'Port 14',
- 'ifName' => '0/14',
- 'ifAlias' => 'Port 14',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 15 =>
- array (
- 'ifDescr' => 'Port 15',
- 'ifName' => '0/15',
- 'ifAlias' => 'MOXA',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 16 =>
- array (
- 'ifDescr' => 'Port 16',
- 'ifName' => '0/16',
- 'ifAlias' => 'LTE_Backup',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 17 =>
- array (
- 'ifDescr' => 'Port 17',
- 'ifName' => '0/17',
- 'ifAlias' => 'SFP 1',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- 18 =>
- array (
- 'ifDescr' => 'Port 18',
- 'ifName' => '0/18',
- 'ifAlias' => 'SFP 2',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'down',
- ),
- )
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[14][0m 3.5ms]
- SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 1","0\/1","Uplink Voorzolder","ethernetCsmacd","up",1,155][0m 1.65ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 2","0\/2","CK2","ethernetCsmacd","up",2,156][0m 1.15ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 3","0\/3","iSCSI switch","ethernetCsmacd","up",3,159][0m 1.14ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 4","0\/4","Solaredge","ethernetCsmacd","up",4,162][0m 1.31ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 5","0\/5","Atlas","ethernetCsmacd","up",5,164][0m 1.46ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 6","0\/6","Port 6","ethernetCsmacd","down",6,166][0m 1.39ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 7","0\/7","NAS MGMT","ethernetCsmacd","up",7,168][0m 1.23ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 8","0\/8","Port 8","ethernetCsmacd","down",8,170][0m 1.19ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 9","0\/9","ESX2 MGMT","ethernetCsmacd","down",9,172][0m 1.01ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 10","0\/10","Port 10","ethernetCsmacd","down",10,174][0m 2.12ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 11","0\/11","ESX1 MGMT","ethernetCsmacd","up",11,176][0m 1.29ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 12","0\/12","Port 12","ethernetCsmacd","down",12,177][0m 1.57ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 13","0\/13","Pi-Zolder","ethernetCsmacd","down",13,178][0m 1.48ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 14","0\/14","Port 14","ethernetCsmacd","down",14,179][0m 1.39ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 15","0\/15","MOXA","ethernetCsmacd","up",15,180][0m 1.33ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 16","0\/16","LTE_Backup","ethernetCsmacd","down",16,181][0m 1.38ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 17","0\/17","SFP 1","ethernetCsmacd","down",17,182][0m 1.21ms]
- .SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifName`=?,`ifAlias`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=? WHERE `port_id` = ? [0;33m["Port 18","0\/18","SFP 2","ethernetCsmacd","down",18,183][0m 1.29ms]
- .
- >> Runtime for discovery module 'ports': 0.2510 seconds with 4432 bytes
- >> [0;36mSNMP[0m: [5/0.21s] [1;33mMySQL[0m: [19/0.28s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports-stack ####
- SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '14' [0;33m[][0m 2.02ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ifStackStatus'[0m]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.0480 seconds with 32 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+
- OS
- Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m]
- entPhysicalEntry = No Such Object available on this agent at this OID
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 1 in (none)
- Invalid snmp_walk() data = entPhysicalEntry = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[14][0m 2.73ms]
- >> Runtime for discovery module 'entity-physical': 0.0420 seconds with 5840 bytes
- >> [0;36mSNMP[0m: [1/0.04s] [1;33mMySQL[0m: [1/0.03s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global-
- OS
- Device
- Module [ entity-state ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ isis ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module processors ####
- No YAML Discovery data.
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.4413.1.1.1.1.4.9.0'[0m]
- No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[14][0m 2.98ms]
- SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 2.03ms]
- >> Runtime for discovery module 'processors': 0.0510 seconds with 2936 bytes
- >> [0;36mSNMP[0m: [1/0.04s] [1;33mMySQL[0m: [2/0.05s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mempools ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUb' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable'[0m]
- EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable = No Such Object available on this agent at this OID
- SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:EdgeSwitch-BOXSERVICES-PRIVATE-MIB\/EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable"][0m 2.92ms]
- SNMP[[0;36m'/usr/bin/snmptranslate' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' '-m' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' '-On' '-Pu' 'EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable'[0m]
- .*.4.1.44*.1.4.2
- SQL[[1;33minsert into `cache` (`key`, `value`, `expiration`) values (?, ?, ?) [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:EdgeSwitch-BOXSERVICES-PRIVATE-MIB\/EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemAvailable","s:29:\".1.3.6.1.4.1.4413.1.1.1.1.4.2\";",1637337762][0m 62.88ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUb' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree'[0m]
- EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree = No Such Object available on this agent at this OID
- SQL[[1;33mselect * from `cache` where `key` = ? limit 1 [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:EdgeSwitch-BOXSERVICES-PRIVATE-MIB\/EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree"][0m 1.54ms]
- SNMP[[0;36m'/usr/bin/snmptranslate' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' '-m' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' '-On' '-Pu' 'EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree'[0m]
- .*.4.1.44*.1.4.1
- SQL[[1;33minsert into `cache` (`key`, `value`, `expiration`) values (?, ?, ?) [0;33m["laravel_cacheYamlDiscovery:oidToNumeric:EdgeSwitch-BOXSERVICES-PRIVATE-MIB\/EdgeSwitch-SWITCHING-MIB::agentSwitchCpuProcessMemFree","s:29:\".1.3.6.1.4.1.4413.1.1.1.1.4.1\";",1637337762][0m 20.18ms]
- SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[14][0m 2.26ms]
- >> Runtime for discovery module 'mempools': 0.3690 seconds with 139512 bytes
- >> [0;36mSNMP[0m: [4/0.26s] [1;33mMySQL[0m: [5/0.90s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+
- OS
- Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[14][0m 1.72ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0020 seconds with 80 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global-
- OS
- Device
- Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-pw ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ vrf ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cef ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ slas ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cbqos ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-otv ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-qfp ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv4-addresses ####
- SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[14][0m 1.91ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m]
- ipAdEntIfIndex.* 1
- ipAdEntIfIndex.* 3
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ipAdEntNetMask.127.0.0.1'[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[14,"1"][0m 1.86ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[14,"1"][0m 1.28ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.0\/8"][0m 2.57ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m["","127.0.0.0\/8"][0m 1.3ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.0\/8"][0m 1.35ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["127.0.0.1",8,155][0m 2.2ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["","127.0.0.1",8,155][0m 1.39ms]
- .SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ipAdEntNetMask.172.16.1.11'[0m]
- *
- SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[14,"3"][0m 1.83ms]
- SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[14,"3"][0m 1.12ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["172.16.1.0\/24"][0m 1.14ms]
- SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m["","172.16.1.0\/24"][0m 1.36ms]
- sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["172.16.1.0\/24"][0m 1.31ms]
- SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["172.16.1.11",24,159][0m 1.44ms]
- SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["","172.16.1.11",24,159][0m 1.67ms]
- .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[14][0m 1.9ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.1540 seconds with 27912 bytes
- >> [0;36mSNMP[0m: [3/0.12s] [1;33mMySQL[0m: [16/0.26s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'[0m]
- ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = .1.3.6.1.2.1.55.1.8.1.2 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[14][0m 2.56ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.0880 seconds with -16 bytes
- >> [0;36mSNMP[0m: [2/0.08s] [1;33mMySQL[0m: [1/0.03s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global-
- OS
- Device
- Module [ route ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module sensors ####
- Caching data: mempools os sensors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'boxServicesTempUnitEntry'[0m]
- boxServicesTempUnitEntry = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = boxServicesTempUnitEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'boxServicesTempSensorsEntry'[0m]
- boxServicesTempSensorsEntry = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = boxServicesTempSensorsEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUs' '-Ih' '-m' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'boxServicesFansEntry'[0m]
- boxServicesFansEntry = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = boxServicesFansEntry = No Such Object available on this agent at this OID
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m]
- entPhysicalDescr = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",14,"ipmi"][0m 5.23ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",14,"ipmi"][0m 5.96ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",14,"ipmi"][0m 3.01ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",14,"ipmi"][0m 3.56ms]
- Airflow: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",14,"snmp"][0m 2.32ms]
- Current: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",14,"snmp"][0m 5.33ms]
- Charge: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",14,"snmp"][0m 8.28ms]
- Dbm: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",14,"snmp"][0m 3.39ms]
- Fanspeed: Dynamic Discovery (fanspeed):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'boxServicesFansEntry',
- 'value' => 'boxServicesFanSpeed',
- 'num_oid' => '.1.3.6.1.4.1.4413.1.1.43.1.6.1.4.{{ $index }}',
- 'index' => 'boxServicesFanSpeed.{{ $index }}',
- 'descr' => 'Fan {{ $index }}',
- ),
- ),
- )
- Data boxServicesFansEntry:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",14,"snmp"][0m 3.34ms]
- Frequency: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",14,"snmp"][0m 2.59ms]
- Humidity: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",14,"snmp"][0m 2.58ms]
- Load: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",14,"snmp"][0m 6.25ms]
- Loss: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",14,"snmp"][0m 2.67ms]
- Power: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",14,"snmp"][0m 2.39ms]
- Power_consumed: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",14,"snmp"][0m 4.17ms]
- Power_factor: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",14,"snmp"][0m 4.32ms]
- Runtime: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",14,"snmp"][0m 3.44ms]
- Signal: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",14,"snmp"][0m 2.59ms]
- State: Dynamic Discovery (state):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'boxServicesTempUnitEntry',
- 'value' => 'boxServicesTempUnitState',
- 'num_oid' => '.1.3.6.1.4.1.4413.1.1.43.1.15.1.2.{{ $index }}',
- 'descr' => 'Chassis state',
- 'index' => 'boxServicesTempUnitState.{{ $index }}',
- 'states' =>
- array (
- 0 =>
- array (
- 'value' => 0,
- 'descr' => 'low',
- 'graph' => 1,
- 'generic' => 1,
- ),
- 1 =>
- array (
- 'value' => 1,
- 'descr' => 'normal',
- 'graph' => 1,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'value' => 2,
- 'descr' => 'warning',
- 'graph' => 1,
- 'generic' => 1,
- ),
- 3 =>
- array (
- 'value' => 3,
- 'descr' => 'critical',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 4 =>
- array (
- 'value' => 4,
- 'descr' => 'shutdown',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'value' => 5,
- 'descr' => 'notpresent',
- 'graph' => 1,
- 'generic' => 3,
- ),
- 6 =>
- array (
- 'value' => 6,
- 'descr' => 'notoperational',
- 'graph' => 1,
- 'generic' => 2,
- ),
- ),
- ),
- 1 =>
- array (
- 'oid' => 'boxServicesTempSensorsEntry',
- 'value' => 'boxServicesTempSensorState',
- 'num_oid' => '.1.3.6.1.4.1.4413.1.1.43.1.8.1.4.{{ $index }}',
- 'descr' => 'Temp Sensor {{ $index }}',
- 'index' => 'boxServicesTempSensorState.{{ $index }}',
- 'states' =>
- array (
- 0 =>
- array (
- 'value' => 0,
- 'descr' => 'low',
- 'graph' => 1,
- 'generic' => 1,
- ),
- 1 =>
- array (
- 'value' => 1,
- 'descr' => 'normal',
- 'graph' => 1,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'value' => 2,
- 'descr' => 'warning',
- 'graph' => 1,
- 'generic' => 1,
- ),
- 3 =>
- array (
- 'value' => 3,
- 'descr' => 'critical',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 4 =>
- array (
- 'value' => 4,
- 'descr' => 'shutdown',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'value' => 5,
- 'descr' => 'notpresent',
- 'graph' => 1,
- 'generic' => 3,
- ),
- 6 =>
- array (
- 'value' => 6,
- 'descr' => 'notoperational',
- 'graph' => 1,
- 'generic' => 2,
- ),
- ),
- ),
- 2 =>
- array (
- 'oid' => 'boxServicesFansEntry',
- 'value' => 'boxServicesFanItemState',
- 'num_oid' => '.1.3.6.1.4.1.4413.1.1.43.1.6.1.3.{{ $index }}',
- 'descr' => 'Fan {{ $index }}',
- 'index' => 'boxServicesFanItemState.{{ $index }}',
- 'states' =>
- array (
- 0 =>
- array (
- 'value' => 1,
- 'descr' => 'notpresent',
- 'graph' => 1,
- 'generic' => 3,
- ),
- 1 =>
- array (
- 'value' => 2,
- 'descr' => 'operational',
- 'graph' => 1,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'value' => 3,
- 'descr' => 'failed',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 3 =>
- array (
- 'value' => 4,
- 'descr' => 'powering',
- 'graph' => 1,
- 'generic' => 0,
- ),
- 4 =>
- array (
- 'value' => 5,
- 'descr' => 'nopower',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'value' => 6,
- 'descr' => 'notpowering',
- 'graph' => 1,
- 'generic' => 2,
- ),
- 6 =>
- array (
- 'value' => 7,
- 'descr' => 'incompatible',
- 'graph' => 1,
- 'generic' => 1,
- ),
- ),
- ),
- ),
- )
- Data boxServicesTempUnitEntry:
- array (
- )
- Data boxServicesTempSensorsEntry:
- array (
- )
- Data boxServicesFansEntry:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",14,"snmp"][0m 13.05ms]
- Count: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",14,"snmp"][0m 2.44ms]
- Temperature: Dynamic Discovery (temperature):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'boxServicesTempSensorsEntry',
- 'value' => 'boxServicesTempSensorTemperature',
- 'num_oid' => '.1.3.6.1.4.1.4413.1.1.43.1.8.1.5.{{ $index }}',
- 'index' => 'boxServicesTempSensorTemperature.{{ $index }}',
- 'descr' => 'Temperature {{ $index }}',
- ),
- ),
- )
- Data boxServicesTempSensorsEntry:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",14,"snmp"][0m 2.7ms]
- Tv_signal: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",14,"snmp"][0m 2.38ms]
- Voltage: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",14,"snmp"][0m 2.76ms]
- Snr: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",14,"snmp"][0m 3.49ms]
- Pressure: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",14,"snmp"][0m 3.76ms]
- Cooling: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",14,"snmp"][0m 2.3ms]
- Delay: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",14,"snmp"][0m 30.38ms]
- Quality_factor: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",14,"snmp"][0m 5.06ms]
- Chromatic_dispersion: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",14,"snmp"][0m 2.47ms]
- Ber: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",14,"snmp"][0m 2.12ms]
- Eer: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",14,"snmp"][0m 2.16ms]
- Waterflow: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",14,"snmp"][0m 3.48ms]
- Percent: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",14,"snmp"][0m 26.94ms]
- >> Runtime for discovery module 'sensors': 0.3720 seconds with 2680 bytes
- >> [0;36mSNMP[0m: [4/0.16s] [1;33mMySQL[0m: [33/1.77s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module storage ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'aixFsTableEntry'[0m]
- Exitcode: 1
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (IBM-AIX-MIB): At line 1 in (none)
- aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (IBM-AIX-MIB): At line 1 in (none)
- aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)
- aix_filesystem : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m]
- fileSystemSpaceTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = fileSystemSpaceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'datasetTable'[0m]
- Exitcode: 1
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (FREENAS-MIB): At line 1 in (none)
- datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (FREENAS-MIB): At line 1 in (none)
- datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable)
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '14' AND `storage_type` != 'dataset' [0;33m[][0m 2.4ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'zpoolTable'[0m]
- Exitcode: 1
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (FREENAS-MIB): At line 1 in (none)
- zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (FREENAS-MIB): At line 1 in (none)
- zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable)
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '14' AND `storage_type` != 'zpool' [0;33m[][0m 2.23ms]
- communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'hrStorageTable'[0m]
- hrStorageTable = No Such Object available on this agent at this OID
- hrStorage : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dskTable'[0m]
- dskTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '14' AND `storage_type` != 'dsk' [0;33m[][0m 1.99ms]
- SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '14' [0;33m[][0m 1.79ms]
- >> Runtime for discovery module 'storage': 0.2180 seconds with 2856 bytes
- >> [0;36mSNMP[0m: [5/0.16s] [1;33mMySQL[0m: [4/0.08s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+
- OS
- Device
- #### Load disco module hr-device ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m]
- hrDeviceIndex.196608 = 196608
- hrDeviceType.196608 = hrDeviceProcessor
- hrDeviceDescr.196608 =
- hrDeviceID.196608 = zeroDotZero
- hrDeviceStatus.196608 = running
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m]
- hrProcessorFrwID.196608 = zeroDotZero
- hrProcessorLoad.196608 = 16
- array (
- 196608 =>
- array (
- 'hrDeviceIndex' => '196608',
- 'hrDeviceType' => 'hrDeviceProcessor',
- 'hrDeviceDescr' => '',
- 'hrDeviceID' => 'zeroDotZero',
- 'hrDeviceStatus' => 'running',
- 'hrProcessorFrwID' => 'zeroDotZero',
- 'hrProcessorLoad' => '16',
- ),
- )
- SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[14,"196608"][0m 2.44ms]
- SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=?,`hrProcessorLoad`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceProcessor","","running",null,"16",14,"196608"][0m 40.23ms]
- .SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '14' [0;33m[][0m 2.49ms]
- >> Runtime for discovery module 'hr-device': 0.1360 seconds with 2488 bytes
- >> [0;36mSNMP[0m: [2/0.09s] [1;33mMySQL[0m: [3/0.45s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+
- OS
- Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'cdpCache'[0m]
- Exitcode: 1
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (CISCO-CDP-MIB): At line 1 in (none)
- cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache)
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/edgeswitch
- Cannot find module (CISCO-CDP-MIB): At line 1 in (none)
- cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache)
- LLDP-MIB: communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'lldpRemTable'[0m]
- lldpRemTable = No Such Object available on this agent at this OID
- OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[14][0m 2.22ms]
- SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[14][0m 2.53ms]
- SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.28ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0840 seconds with 48 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [3/0.06s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+
- OS
- Device
- #### Load disco module arp-table ####
- communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'EdgeSwitch-SWITCHING-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'agentDynamicDsBindingTable'[0m]
- agentDynamicDsBindingTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[14,""][0m 2.59ms]
- Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/arp-table.inc.php on line 51
- SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 2.01ms]
- >> Runtime for discovery module 'arp-table': 0.0670 seconds with 192 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [2/0.05s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global-
- OS
- Device
- Module [ discovery-arp ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module bgp-peers ####
- SNMP[[0;36m'/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m]
- "FC EC DA 77 73 21 "
- No BGP on hostPeers :
- SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[14,""][0m 2.07ms]
- SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[14,""][0m 1.73ms]
- SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[14][0m 1.59ms]
- >> Runtime for discovery module 'bgp-peers': 0.0430 seconds with 632 bytes
- >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [3/0.05s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+
- OS
- Device
- #### Load disco module vlans ####
- SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[14][0m 1.95ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m]
- version1
- ver version1 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qVlanStaticName'[0m]
- dot1qVlanStaticName = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = dot1qVlanStaticName = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '--hexOutputLength=0' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qVlanCurrentEgressPorts'[0m]
- dot1qVlanCurrentEgressPorts.0.1 = "00 00 00 00 00 07 7F CE "
- dot1qVlanCurrentEgressPorts.0.2 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.3 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.4 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.5 = "00 00 00 00 00 07 FF 4A "
- dot1qVlanCurrentEgressPorts.0.6 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.7 = "00 00 00 00 00 07 7F 6A "
- dot1qVlanCurrentEgressPorts.0.8 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.9 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.10 = "00 00 00 00 00 07 7F 5A "
- dot1qVlanCurrentEgressPorts.0.25 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.40 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.60 = "00 00 00 00 00 07 7F 4A "
- dot1qVlanCurrentEgressPorts.0.100 = "00 00 00 00 00 07 7F 4A "
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '--hexOutputLength=0' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qVlanCurrentUntaggedPorts'[0m]
- dot1qVlanCurrentUntaggedPorts.0.1 = "00 00 00 00 00 07 7F CE "
- dot1qVlanCurrentUntaggedPorts.0.2 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.3 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.4 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.5 = "00 00 00 00 00 00 80 00 "
- dot1qVlanCurrentUntaggedPorts.0.6 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.7 = "00 00 00 00 00 00 00 20 "
- dot1qVlanCurrentUntaggedPorts.0.8 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.9 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.10 = "00 00 00 00 00 00 00 10 "
- dot1qVlanCurrentUntaggedPorts.0.25 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.40 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.60 = "00 00 00 00 00 00 00 00 "
- dot1qVlanCurrentUntaggedPorts.0.100 = "00 00 00 00 00 00 00 00 "
- >> Runtime for discovery module 'vlans': 0.6860 seconds with 16424 bytes
- >> [0;36mSNMP[0m: [5/0.68s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global-
- OS
- Device
- Module [ vmware-vminfo ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ libvirt-vminfo ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ printer-supplies ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'diskIOEntry'[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '14' [0;33m[][0m 2.03ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0350 seconds with 160 bytes
- >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global-
- OS
- Device
- Module [ applications ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 80 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+
- OS
- Device
- #### Load disco module stp ####
- SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[14][0m 2.33ms]
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1dStpProtocolSpecification.0'[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0360 seconds with 80 bytes
- >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 80 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global-
- OS
- Device
- Module [ loadbalancers ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ mef ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module wireless ####
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"ap-count"][0m 3.08ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"clients"][0m 2.06ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"quality"][0m 2.03ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"capacity"][0m 1.98ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"utilization"][0m 1.85ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"rate"][0m 3.68ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"ccq"][0m 2.13ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"snr"][0m 1.94ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"sinr"][0m 2.01ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"rsrp"][0m 1.57ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"rsrq"][0m 1.62ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"ssr"][0m 1.56ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"mse"][0m 2.35ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"xpi"][0m 2.25ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"rssi"][0m 2ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"power"][0m 2.32ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"noise-floor"][0m 1.79ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"errors"][0m 1.83ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"error-ratio"][0m 1.9ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"error-rate"][0m 2.08ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"frequency"][0m 1.59ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"distance"][0m 2.14ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"cell"][0m 3.18ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[14,"channel"][0m 1.85ms]
- >> Runtime for discovery module 'wireless': 0.0670 seconds with 10600 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [24/0.51s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+
- OS
- Device
- #### Load disco module fdb-table ####
- SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[14][0m 1.67ms]
- SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[14][0m 2.39ms]
- communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'EdgeSwitch-SWITCHING-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'agentDynamicDsBindingTable'[0m]
- agentDynamicDsBindingTable = No Such Object available on this agent at this OID
- communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m]
- dot1qTpFdbPort[1][0:c:29:e:51:1b] = 11
- dot1qTpFdbPort[1][0:c:29:1e:95:1d] = 11
- dot1qTpFdbPort[1][0:11:32:9b:b:cf] = 7
- dot1qTpFdbPort[1][0:50:56:a1:13:d] = 11
- dot1qTpFdbPort[1][0:50:56:a1:5a:b9] = 11
- dot1qTpFdbPort[1][0:50:56:a1:d0:68] = 11
- dot1qTpFdbPort[1][0:50:56:ae:bd:73] = 11
- dot1qTpFdbPort[1][0:50:56:ae:c1:19] = 11
- dot1qTpFdbPort[1][0:50:56:ae:eb:28] = 11
- dot1qTpFdbPort[1][0:50:56:b7:65:b1] = 11
- dot1qTpFdbPort[1][2:42:ac:10:1:d6] = 7
- dot1qTpFdbPort[1][2:42:ac:10:1:fd] = 7
- dot1qTpFdbPort[1][2:42:ac:10:1:fe] = 7
- dot1qTpFdbPort[1][4:18:d6:a0:d5:d6] = 2
- dot1qTpFdbPort[1][24:5a:4c:6e:ef:49] = 1
- dot1qTpFdbPort[1][2e:64:4e:61:67:4a] = 1
- dot1qTpFdbPort[1][3e:93:50:df:fc:f0] = 1
- dot1qTpFdbPort[1][68:d7:9a:2a:df:dd] = 1
- dot1qTpFdbPort[1][74:83:c2:c:1c:8c] = 1
- dot1qTpFdbPort[1][74:83:c2:9f:4b:f] = 3
- dot1qTpFdbPort[1][74:83:c2:9f:4b:10] = 3
- dot1qTpFdbPort[1][94:c6:91:a4:59:87] = 1
- dot1qTpFdbPort[1][b8:27:eb:39:2a:7a] = 1
- dot1qTpFdbPort[1][b8:27:eb:60:e3:aa] = 1
- dot1qTpFdbPort[1][c4:2f:90:a:e6:aa] = 1
- dot1qTpFdbPort[1][f0:9f:c2:dc:d1:2a] = 1
- dot1qTpFdbPort[1][f4:4d:30:63:5b:40] = 11
- dot1qTpFdbPort[1][fc:ec:da:77:46:86] = 1
- dot1qTpFdbPort[1][fc:ec:da:77:56:6] = 1
- dot1qTpFdbPort[2][74:83:c2:9f:4b:f] = 3
- dot1qTpFdbPort[2][94:c6:91:a4:59:87] = 1
- dot1qTpFdbPort[3][0:c:29:5a:ae:78] = 11
- dot1qTpFdbPort[3][0:11:32:9b:b:d0] = 3
- dot1qTpFdbPort[3][fc:ec:da:77:56:6] = 1
- dot1qTpFdbPort[4][0:19:8f:17:d9:9] = 1
- dot1qTpFdbPort[5][0:50:56:ae:99:ca] = 11
- dot1qTpFdbPort[5][0:90:e8:68:ba:98] = 15
- dot1qTpFdbPort[5][74:83:c2:9f:4b:f] = 3
- dot1qTpFdbPort[5][94:c6:91:a4:59:87] = 1
- Q-BRIDGE-MIB:communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- communityStringIndexing
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/edgeswitch' 'udp:HOSTNAME:161' 'dot1qVlanFdbId'[0m]
- dot1qVlanFdbId[0][1] = 1
- dot1qVlanFdbId[0][2] = 2
- dot1qVlanFdbId[0][3] = 3
- dot1qVlanFdbId[0][4] = 4
- dot1qVlanFdbId[0][5] = 5
- dot1qVlanFdbId[0][6] = 6
- dot1qVlanFdbId[0][7] = 7
- dot1qVlanFdbId[0][8] = 8
- dot1qVlanFdbId[0][9] = 9
- dot1qVlanFdbId[0][10] = 10
- dot1qVlanFdbId[0][25] = 25
- dot1qVlanFdbId[0][40] = 40
- dot1qVlanFdbId[0][60] = 60
- dot1qVlanFdbId[0][100] = 100
- vlan 1 mac 000c290e511b port (11)
- vlan 1 mac 000c291e951d port (11)
- vlan 1 mac 0011329b0bcf port (7)
- vlan 1 mac 005056a1130d port (11)
- vlan 1 mac 005056a15ab9 port (11)
- vlan 1 mac 005056a1d068 port (11)
- vlan 1 mac 005056aebd73 port (11)
- vlan 1 mac 005056aec119 port (11)
- vlan 1 mac 005056aeeb28 port (11)
- vlan 1 mac 005056b765b1 port (11)
- vlan 1 mac 0242ac1001d6 port (7)
- vlan 1 mac 0242ac1001fd port (7)
- vlan 1 mac 0242ac1001fe port (7)
- vlan 1 mac 0418d6a0d5d6 port (2)
- vlan 1 mac 245a4c6eef49 port (1)
- vlan 1 mac 2e644e61674a port (1)
- vlan 1 mac 3e9350dffcf0 port (1)
- vlan 1 mac 68d79a2adfdd port (1)
- vlan 1 mac 7483c20c1c8c port (1)
- vlan 1 mac 7483c29f4b0f port (3)
- vlan 1 mac 7483c29f4b10 port (3)
- vlan 1 mac 94c691a45987 port (1)
- vlan 1 mac b827eb392a7a port (1)
- vlan 1 mac b827eb60e3aa port (1)
- vlan 1 mac c42f900ae6aa port (1)
- vlan 1 mac f09fc2dcd12a port (1)
- vlan 1 mac f44d30635b40 port (11)
- vlan 1 mac fcecda774686 port (1)
- vlan 1 mac fcecda775606 port (1)
- vlan 2 mac 7483c29f4b0f port (3)
- vlan 2 mac 94c691a45987 port (1)
- vlan 3 mac 000c295aae78 port (11)
- vlan 3 mac 0011329b0bd0 port (3)
- vlan 3 mac fcecda775606 port (1)
- vlan 4 mac 00198f17d909 port (1)
- vlan 5 mac 005056ae99ca port (11)
- vlan 5 mac 0090e868ba98 port (15)
- vlan 5 mac 7483c29f4b0f port (3)
- vlan 5 mac 94c691a45987 port (1)
- : ................SQL[[1;33minsert into `ports_fdb` (`port_id`, `mac_address`, `vlan_id`, `device_id`, `created_at`, `updated_at`) values (?, ?, ?, ?, ?, ?) [0;33m["","3e9350dffcf0",0,14,"2021-11-19 16:32:45","2021-11-19 16:32:45"][0m 33.94ms]
- +.................
- SQL[[1;33mupdate `ports_fdb` set `updated_at` = ? where `ports_fdb_id` in (?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?, ?) [0;33m["2021-11-19 16:32:45",32,34,38,40,42,44,46,48,50,54,56,58,60,62,64,66,70,72,74,76,78,80,82,84,86,89,90,91,92,93,108,95,96][0m 20.88ms]
- >> Runtime for discovery module 'fdb-table': 1.0770 seconds with 29008 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [4/0.59s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module fdb-table ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mpls ####
- >> Runtime for discovery module 'mpls': 0.0000 seconds with 488 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module mpls ####
- SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[5.18,14][0m 9.94ms]
- Discovered in 5.18 seconds
- discovery.php swzolder.high.local 2021-11-19 16:32:45 - 1 devices discovered in 5.503 secs
- [0;36mSNMP[0m [41/2.17s]: Snmpget[11/0.44s] Snmpwalk[27/1.61s] Snmptranslate[2/0.09s] Snmpgetnext[1/0.03s]
- [1;33mSQL[0m [136/5.67s]: Select[103/3.39s] Update[25/1.01s] Delete[5/0.09s] Insert[3/1.17s]
- [0;32mRRD[0m [0/0.00s]: