- LibreNMS Discovery
- SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 0.49ms]
- SQL[[1;33mselect count(*) as aggregate from `migrations` [0;33m[][0m 0.42ms]
- SQL[[1;33mselect version() [0;33m[][0m 0.35ms]
- ===========================================
- Component | Version
- --------- | -------
- LibreNMS | 24.6.0 (2024-06-16T18:23:37+02:00)
- DB Schema | 2024_04_29_183605_custom_maps_drop_background_suffix_and_background_version (294)
- PHP | 8.1.28
- Python | 3.6.8
- Database | MariaDB 10.5.24-MariaDB
- RRDTool | 1.4.8
- SNMP | 5.7.2
- ===========================================
- DEBUG!
- Updating os_def.cache
- SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE 'skycontrol' ORDER BY device_id DESC [0;33m[][0m 0.84ms]
- skycontrol 8 linux SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[8][0m 0.6ms]
- SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[8][0m 0.4ms]
- [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' 'skycontrol'
- response: skycontrol : xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.36/0.42/0.49
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'[0m]
- SNMPv2-MIB::sysObjectID.0 = NET-SNMP-MIB::netSnmpAgentOIDs.10
- Modules status: Global+
- OS
- Device
- #### Load disco module core ####
- Attempting to initialize OS: linux
- OS initialized: LibreNMS\OS\Linux
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' '-r' '4' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0'[0m]
- .*.*.0 = .*.4.1.8*
- .*.*.0 = Skycontrol EMS
- .*.*.0 = skycontrol
- | Skycontrol EMS | .1.3.6.1.4.1.8072.3.2.10 |
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/haproxy' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'EXCELIANCE-MIB::alProductName'[0m]
- EXCELIANCE-MIB::alProductName = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/arris' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.1166.1.621.14.2.0'[0m]
- SNMPv2-SMI::enterprises.1166.1.6* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.7890.1.101.1'[0m]
- SNMPv2-SMI::enterprises.2021.78* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.3.1.2.6.100.105.115.116.114.111'[0m]
- NET-SNMP-MIB::netSnmpObjects.*.*.* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cirpack' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.9193.1.0'[0m]
- SNMPv2-SMI::enterprises.9193.1.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."distro"'[0m]
- NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[distro] = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ddn' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'SFA-INFO::systemName.0'[0m]
- SFA-INFO::systemName.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.5.0.11.0'[0m]
- SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.12.1.16.0'[0m]
- SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.14.1.16.0'[0m]
- SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/eltek' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.12148.10.2.6.0'[0m]
- SNMPv2-SMI::enterprises.12*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/extrahop' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'EXTRAHOP-MIB::extrahopInfoVersionString'[0m]
- EXTRAHOP-MIB::extrahopInfoVersionString = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.2.1.3.7.118.101.114.115.105.111.110'[0m]
- NET-SNMP-MIB::netSnmpObjects.*.*.*.110 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/checkpoint' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'CHECKPOINT-MIB::osName.0'[0m]
- CHECKPOINT-MIB::osName.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hikvision' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.39165.1.1.0'[0m]
- SNMPv2-SMI::enterprises.39* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/huawei' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2011.6.164.1.1.1.4.0'[0m]
- SNMPv2-SMI::enterprises.2*.* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/infinera' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'CORIANT-GROOVE-MIB::softwareloadSwloadProduct.1'[0m]
- CORIANT-GROOVE-MIB::softwareloadSwloadProduct[1] = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.54849.1.1.4.0'[0m]
- SNMPv2-SMI::enterprises.548*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/trellix' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8962.2.1.2.1.1.6.0'[0m]
- SNMPv2-SMI::enterprises.89*.* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'UPS-MIB::upsIdentAgentSoftwareVersion.0'[0m]
- UPS-MIB::upsIdentAgentSoftwareVersion.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."distro"'[0m]
- NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[distro] = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/orvaldi' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.21111.1.1.1.6.0'[0m]
- SNMPv2-SMI::enterprises.21*.6.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '1.3.6.1.4.1.4515.1.3.6.1.1.1.2.0'[0m]
- SNMPv2-SMI::enterprises.45*.*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/carel' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'CAREL-ug40cdz-MIB::roomTemp.0'[0m]
- CAREL-ug40cdz-MIB::roomTemp.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/primekey' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'PK-SOFTWARE-APPLIANCE-V2::pk-SAV2-systemVersion.0'[0m]
- PK-SOFTWARE-APPLIANCE-V2::pk-SAV2-systemVersion.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/primekey' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'PRIMEKEY-APPLIANCE-MIB::pkAVersion'[0m]
- PRIMEKEY-APPLIANCE-MIB::pkAVersion = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/osnexus' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'QUANTASTOR-SYS-STATS::storageSystem-ProductId.0'[0m]
- QUANTASTOR-SYS-STATS::storageSystem-ProductId[0] = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/unitrends' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.21865.1.6.1.0'[0m]
- SNMPv2-SMI::enterprises.218*.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/toshiba' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'UPS-MIB::upsIdentAgentSoftwareVersion.0'[0m]
- UPS-MIB::upsIdentAgentSoftwareVersion.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/teltonika' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.48690.1.3.0'[0m]
- SNMPv2-SMI::enterprises.486* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/checkpoint' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'CHECKPOINT-MIB::osName.0'[0m]
- CHECKPOINT-MIB::osName.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'ATEN-IPMI-MIB::bmcMajorVesion.0'[0m]
- ATEN-IPMI-MIB::bmcMajorVesion.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.7890.1.101.1'[0m]
- SNMPv2-SMI::enterprises.2021.78* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/wisi' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.2'[0m]
- SNMPv2-SMI::enterprises.74*.*.1.2 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/wti' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'WTI-MPC-MIB::environmentUnitName.1'[0m]
- WTI-MPC-MIB::environmentUnitName[1] = No Such Object available on this agent at this OID
- OS: Linux (linux)
- Attempting to initialize OS: linux
- OS initialized: LibreNMS\OS\Linux
- >> Runtime for discovery module 'core': 1.1650 seconds with 114632 bytes
- >> [0;36mSNMP[0m: [36/1.13s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+
- OS
- Device
- #### Load disco module os ####
- Yaml location data:
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'[0m]
- Skycontrol EMS
- SQL[[1;33mselect * from `locations` where (`location` = ?) limit 1 [0;33m["Skycontrol EMS"][0m 1.06ms]
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'sysContact.0'[0m]
- support@skycontrol.com
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' '-r' '4' 'udp:HOSTNAME:161' 'MIB-Dell-10892::chassisModelName.1' 'MIB-Dell-10892::chassisServiceTagName.1'[0m]
- MIB-Dell-10892::chassisModelName.1 = No Such Object available on this agent at this OID
- MIB-Dell-10892::chassisServiceTagName.1 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hp' '-r' '4' 'udp:HOSTNAME:161' 'CPQSINFO-MIB::cpqSiProductName.0' 'CPQSINFO-MIB::cpqSiSysSerialNum.0'[0m]
- CPQSINFO-MIB::cpqSiProductName.0 = No Such Object available on this agent at this OID
- CPQSINFO-MIB::cpqSiSysSerialNum.0 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' '-r' '4' 'udp:HOSTNAME:161' 'SUPERMICRO-SD5-MIB::mbProductName.1' 'SUPERMICRO-SD5-MIB::mbSerialNumber.1'[0m]
- SUPERMICRO-SD5-MIB::mbProductName.1 = No Such Object available on this agent at this OID
- SUPERMICRO-SD5-MIB::mbSerialNumber.1 = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."distro"' '.1.3.6.1.4.1.2021.7890.1.3.1.1.6.100.105.115.116.114.111' '.1.3.6.1.4.1.2021.7890.1.101.1'[0m]
- NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[distro] = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78*.*.* = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."hardware"' '.1.3.6.1.4.1.2021.7890.2.4.1.2.8.104.97.114.100.119.97.114.101.1' '.1.3.6.1.4.1.2021.7890.2.101.2'[0m]
- NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[hardware] = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78*.*.*.114.101.1 = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78* = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."serial"' '.1.3.6.1.4.1.2021.7890.4.4.1.2.6.115.101.114.105.97.108.1' '.1.3.6.1.4.1.2021.7890.4.101.1'[0m]
- NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[serial] = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78*.*.*.1 = No Such Object available on this agent at this OID
- SNMPv2-SMI::enterprises.2021.78* = No Such Object available on this agent at this OID
- Location: Skycontrol EMS
- Hardware:
- OS Version:
- OS Features:
- Serial:
- >> Runtime for discovery module 'os': 0.3280 seconds with 693072 bytes
- >> [0;36mSNMP[0m: [9/0.31s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifDescr'[0m]
- ifDescr = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ifDescr = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifName'[0m]
- ifName = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ifName = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifAlias'[0m]
- ifAlias = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ifAlias = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifType'[0m]
- ifType = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ifType = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifOperStatus'[0m]
- ifOperStatus = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = ifOperStatus = No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[8][0m 0.89ms]
- >> Runtime for discovery module 'ports': 0.2300 seconds with 16016 bytes
- >> [0;36mSNMP[0m: [5/0.23s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports-stack ####
- SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '8' [0;33m[][0m 0.36ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ifStackStatus'[0m]
- ifStackStatus = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'ports-stack': 0.0640 seconds with 1928 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global-
- OS
- Device
- Module [ xdsl ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m]
- entPhysicalEntry = No Such Object available on this agent at this OID
- MIB search path: /opt/librenms/mibs
- Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 1 in (none)
- Invalid snmp_walk() data = entPhysicalEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'adapterInfoTable'[0m]
- adapterInfoTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = adapterInfoTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'enclosureTable'[0m]
- enclosureTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = enclosureTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'physicalDriveTable'[0m]
- physicalDriveTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = physicalDriveTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'bbuTable'[0m]
- bbuTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = bbuTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[8][0m 0.64ms]
- >> Runtime for discovery module 'entity-physical': 0.3600 seconds with 29408 bytes
- >> [0;36mSNMP[0m: [5/0.36s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global+
- OS
- Device
- #### Load disco module entity-state ####
- SQL[[1;33mSELECT entPhysical_id, entPhysicalIndex FROM entPhysical WHERE device_id=? [0;33m[8][0m 0.39ms]
- >> Runtime for discovery module 'entity-state': 0.0000 seconds with 1880 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module entity-state ####
- Modules status: Global-
- OS
- Device
- Module [ isis ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'hrProcessorLoad'[0m]
- hrProcessorLoad = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = hrProcessorLoad = No Such Object available on this agent at this OID
- UCD Resources: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'[0m]
- No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[8][0m 0.68ms]
- SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.02ms]
- >> Runtime for discovery module 'processors': 0.1110 seconds with 109352 bytes
- >> [0;36mSNMP[0m: [2/0.10s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mempools ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'hrStorageTable'[0m]
- hrStorageTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'hrMemorySize.0'[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0'[0m]
- memTotalSwap.0 = No Such Object available on this agent at this OID
- memAvailSwap.0 = No Such Object available on this agent at this OID
- memTotalReal.0 = No Such Object available on this agent at this OID
- memAvailReal.0 = No Such Object available on this agent at this OID
- memBuffer.0 = No Such Object available on this agent at this OID
- memCached.0 = No Such Object available on this agent at this OID
- memSysAvail.0 = No Such Object available on this agent at this OID
- SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[8][0m 0.65ms]
- >> Runtime for discovery module 'mempools': 0.1190 seconds with 97960 bytes
- >> [0;36mSNMP[0m: [2/0.05s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+
- OS
- Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[8][0m 0.36ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2552 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global-
- OS
- Device
- Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-pw ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ vrf ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cef ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ slas ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cbqos ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-otv ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-qfp ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv4-addresses ####
- SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[8][0m 0.44ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'IP-MIB::ipAdEntIfIndex'[0m]
- ipAdEntIfIndex = No Such Object available on this agent at this OID
- SQL[[1;33mselect `ipv4_address_id`, `ipv4_address`, `ipv4_prefixlen`, `ipv4_network_id`, `ports`.`device_id`, `ports`.`ifIndex` from `ipv4_addresses` left join `ports` on `ipv4_addresses`.`port_id` = `ports`.`port_id` where `ports`.`device_id` = ? or `ports`.`device_id` is null [0;33m[8][0m 2.03ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.0380 seconds with 171232 bytes
- >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUt' '-r' '4' 'udp:HOSTNAME:161' 'IP-MIB::ipAddressIfIndex.ipv6'[0m]
- IP-MIB::ipAddressIfIndex[ipv6] = No Such Object available on this agent at this OID
- SNMP query failed. Exit Code: 0 Empty: false Bad String: No Such Object available on this agent at this OID
- SNMP failed walking IP-MIB::ipAddressIfIndex.ipv6 of IP-MIB::ipAddressIfIndex.ipv6,IP-MIB::ipAddressOrigin.ipv6,IP-MIB::ipAddressPrefix.ipv6 aborting.
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = .1.3.6.1.2.1.55.1.8.1.2 No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[8][0m 0.78ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.1030 seconds with 5824 bytes
- >> [0;36mSNMP[0m: [2/0.10s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global-
- OS
- Device
- Module [ route ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module sensors ####
- Pre-cache linux: RaspberryPi SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121'[0m]
- nsExtendOutLine."raspberry" = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = nsExtendOutLine.raspberry = No Such Object available on this agent at this OID
- array (
- 'raspberry_pi_sensors' =>
- array (
- ),
- )
- Caching data: sensors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'adapterPropertiesTable'[0m]
- adapterPropertiesTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = adapterPropertiesTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'bbuTable'[0m]
- bbuTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = bbuTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'physicalDriveTable'[0m]
- physicalDriveTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = physicalDriveTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'enclosurePowerSupplyTable'[0m]
- enclosurePowerSupplyTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = enclosurePowerSupplyTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'enclosureFanTable'[0m]
- enclosureFanTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = enclosureFanTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'enclosureAlarmTable'[0m]
- enclosureAlarmTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = enclosureAlarmTable = No Such Object available on this agent at this OID
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m]
- entPhysicalDescr = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",8,"ipmi"][0m 1.06ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",8,"ipmi"][0m 0.61ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",8,"ipmi"][0m 0.62ms]
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",8,"ipmi"][0m 0.6ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsb' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'nsExtendOutLine."rpigpiomonitor"'[0m]
- nsExtendOutLine.*.*.*.116.111.114 = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = nsExtendOutLine.14.114.112.105.103.112.105.111.109.111.110.105.116.111.114 = No Such Object available on this agent at this OID
- Airflow: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",8,"snmp"][0m 2.27ms]
- Current: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",8,"snmp"][0m 0.7ms]
- Charge: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutLine."ups-nut"'[0m]
- nsExtendOutLine[ups-nut] = No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",8,"snmp"][0m 1.26ms]
- Dbm: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",8,"snmp"][0m 0.65ms]
- Fanspeed: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'LM-SENSORS-MIB::lmSensors'[0m]
- lmSensors = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.3'[0m]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = .1.3.6.1.4.1.10876.2.1.1.1.1.3 No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",8,"snmp"][0m 1.08ms]
- Frequency: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",8,"snmp"][0m 0.72ms]
- Humidity: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",8,"snmp"][0m 0.65ms]
- Load: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",8,"snmp"][0m 0.77ms]
- Loss: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",8,"snmp"][0m 0.65ms]
- Power: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",8,"snmp"][0m 0.66ms]
- Power_consumed: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",8,"snmp"][0m 0.63ms]
- Power_factor: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",8,"snmp"][0m 0.64ms]
- Runtime: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",8,"snmp"][0m 1ms]
- Signal: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",8,"snmp"][0m 0.59ms]
- State: Dynamic Discovery (state):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'alarmState',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.4.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'descr' => 'Alarm',
- 'state_name' => 'alarmState',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'disabled',
- 'graph' => 0,
- 'value' => 0,
- 'generic' => 1,
- ),
- 1 =>
- array (
- 'descr' => 'enabled',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 0,
- ),
- ),
- ),
- 1 =>
- array (
- 'oid' => 'enclosurePowerSupplyTable',
- 'value' => 'powerSupplyStatus',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.5.1.3.{{ $index }}',
- 'group' => 'Enclosure {{ $enclosureId-EPST }}',
- 'descr' => 'Powersupply {{ $powerSupplyID }}',
- 'state_name' => 'powerSupplyStatus',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'invalid',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 2,
- ),
- 1 =>
- array (
- 'descr' => 'ok',
- 'graph' => 0,
- 'value' => 2,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'descr' => 'critical',
- 'graph' => 0,
- 'value' => 3,
- 'generic' => 2,
- ),
- 3 =>
- array (
- 'descr' => 'nonCritical',
- 'graph' => 0,
- 'value' => 4,
- 'generic' => 1,
- ),
- 4 =>
- array (
- 'descr' => 'unrecoverable',
- 'graph' => 0,
- 'value' => 5,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'descr' => 'notInstalled',
- 'graph' => 0,
- 'value' => 6,
- 'generic' => 3,
- ),
- 6 =>
- array (
- 'descr' => 'unknown',
- 'graph' => 0,
- 'value' => 7,
- 'generic' => 1,
- ),
- 7 =>
- array (
- 'descr' => 'notAvailible',
- 'graph' => 0,
- 'value' => 8,
- 'generic' => 3,
- ),
- ),
- ),
- 2 =>
- array (
- 'oid' => 'enclosureFanTable',
- 'value' => 'fanStatus',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.3.1.3.{{ $index }}',
- 'group' => 'Enclosure {{ $enclosureId }}',
- 'descr' => 'FAN {{ $fanID }}',
- 'state_name' => 'fanStatus',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'invalid',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 2,
- ),
- 1 =>
- array (
- 'descr' => 'ok',
- 'graph' => 0,
- 'value' => 2,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'descr' => 'critical',
- 'graph' => 0,
- 'value' => 3,
- 'generic' => 2,
- ),
- 3 =>
- array (
- 'descr' => 'nonCritical',
- 'graph' => 0,
- 'value' => 4,
- 'generic' => 1,
- ),
- 4 =>
- array (
- 'descr' => 'unrecoverable',
- 'graph' => 0,
- 'value' => 5,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'descr' => 'notInstalled',
- 'graph' => 0,
- 'value' => 6,
- 'generic' => 3,
- ),
- 6 =>
- array (
- 'descr' => 'unknown',
- 'graph' => 0,
- 'value' => 7,
- 'generic' => 1,
- ),
- 7 =>
- array (
- 'descr' => 'notAvailible',
- 'graph' => 0,
- 'value' => 8,
- 'generic' => 3,
- ),
- ),
- ),
- 3 =>
- array (
- 'oid' => 'enclosureAlarmTable',
- 'value' => 'alarmStatus',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.7.{{ $index }}',
- 'group' => 'Enclosure {{ $enclosureId-EAT }}',
- 'descr' => 'Alarm',
- 'state_name' => 'alarmStatus',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'invalid',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 2,
- ),
- 1 =>
- array (
- 'descr' => 'ok',
- 'graph' => 0,
- 'value' => 2,
- 'generic' => 0,
- ),
- 2 =>
- array (
- 'descr' => 'critical',
- 'graph' => 0,
- 'value' => 3,
- 'generic' => 2,
- ),
- 3 =>
- array (
- 'descr' => 'nonCritical',
- 'graph' => 0,
- 'value' => 4,
- 'generic' => 1,
- ),
- 4 =>
- array (
- 'descr' => 'unrecoverable',
- 'graph' => 0,
- 'value' => 5,
- 'generic' => 2,
- ),
- 5 =>
- array (
- 'descr' => 'notInstalled',
- 'graph' => 0,
- 'value' => 6,
- 'generic' => 3,
- ),
- 6 =>
- array (
- 'descr' => 'unknown',
- 'graph' => 0,
- 'value' => 7,
- 'generic' => 1,
- ),
- 7 =>
- array (
- 'descr' => 'notAvailible',
- 'graph' => 0,
- 'value' => 8,
- 'generic' => 3,
- ),
- ),
- ),
- 4 =>
- array (
- 'oid' => 'bbuTable',
- 'value' => 'chargerStatus',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID }}',
- 'descr' => 'BBU charger',
- 'state_name' => 'chargerStatus',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'notAvailible',
- 'graph' => 0,
- 'value' => -1,
- 'generic' => 3,
- ),
- 1 =>
- array (
- 'descr' => 'off',
- 'graph' => 0,
- 'value' => 0,
- 'generic' => 2,
- ),
- 2 =>
- array (
- 'descr' => 'complete',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 0,
- ),
- 3 =>
- array (
- 'descr' => 'progress',
- 'graph' => 0,
- 'value' => 2,
- 'generic' => 1,
- ),
- ),
- ),
- 5 =>
- array (
- 'oid' => 'bbuTable',
- 'value' => 'batteryReplacement',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID }}',
- 'descr' => 'BBU replacement',
- 'state_name' => 'batteryReplacement',
- 'states' =>
- array (
- 0 =>
- array (
- 'descr' => 'not availible',
- 'graph' => 0,
- 'value' => -1,
- 'generic' => 3,
- ),
- 1 =>
- array (
- 'descr' => 'needsReplacement',
- 'graph' => 0,
- 'value' => 1,
- 'generic' => 2,
- ),
- 2 =>
- array (
- 'descr' => 'ok',
- 'graph' => 0,
- 'value' => 0,
- 'generic' => 0,
- ),
- ),
- ),
- ),
- )
- Data adapterPropertiesTable:
- array (
- )
- Data enclosurePowerSupplyTable:
- array (
- )
- Data enclosureFanTable:
- array (
- )
- Data enclosureAlarmTable:
- array (
- )
- Data bbuTable:
- array (
- )
- Data bbuTable:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",8,"snmp"][0m 0.6ms]
- Count: Dynamic Discovery (count):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'vdPresentCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.18.{{ $index }}',
- 'index' => 'vdsum.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'descr' => 'Virtual disks',
- ),
- 1 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'vdDegradedCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.19.{{ $index }}',
- 'index' => 'vddegraded.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'high_limit' => 0,
- 'descr' => 'Virtual disk degraded',
- ),
- 2 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'pdDiskPredFailureCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.23.{{ $index }}',
- 'index' => 'criticaldisks.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'high_limit' => 0,
- 'descr' => 'Critical disks',
- ),
- 3 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'pdDiskFailedCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.24.{{ $index }}',
- 'index' => 'faileddisks.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'high_limit' => 0,
- 'descr' => 'Failed disks',
- ),
- 4 =>
- array (
- 'oid' => 'physicalDriveTable',
- 'value' => 'mediaErrCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.7.{{ $index }}',
- 'index' => 'mediaerr.slot.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId }}',
- 'warn_limit' => 1,
- 'descr' => '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber }} Media Errors',
- ),
- 5 =>
- array (
- 'oid' => 'physicalDriveTable',
- 'value' => 'otherErrCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.8.{{ $index }}',
- 'index' => 'othererr.slot.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId }}',
- 'warn_limit' => 1,
- 'descr' => '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber }} Other Errors',
- ),
- 6 =>
- array (
- 'oid' => 'physicalDriveTable',
- 'value' => 'predFailCount',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.9.{{ $index }}',
- 'index' => 'predfail.slot.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId }}',
- 'warn_limit' => 0,
- 'descr' => '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber }} Predictive Failures',
- ),
- ),
- )
- Data adapterPropertiesTable:
- array (
- )
- Data adapterPropertiesTable:
- array (
- )
- Data adapterPropertiesTable:
- array (
- )
- Data adapterPropertiesTable:
- array (
- )
- Data physicalDriveTable:
- array (
- )
- Data physicalDriveTable:
- array (
- )
- Data physicalDriveTable:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",8,"snmp"][0m 0.61ms]
- Temperature: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqve' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1'[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.3'[0m]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = .1.3.6.1.4.1.10876.2.1.1.1.1.3 No Such Object available on this agent at this OID
- Dynamic Discovery (temperature):
- array (
- 'data' =>
- array (
- 0 =>
- array (
- 'oid' => 'adapterPropertiesTable',
- 'value' => 'temperatureROC',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.42.{{ $index }}',
- 'index' => 'controllertemp.{{ $index }}',
- 'group' => 'RAID Controller {{ $adapterID-APT }}',
- 'descr' => 'Controller',
- ),
- 1 =>
- array (
- 'oid' => 'bbuTable',
- 'value' => 'temperature',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16.{{ $index }}',
- 'index' => 'bbutemp.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID }}',
- 'descr' => 'BBU',
- ),
- 2 =>
- array (
- 'oid' => 'physicalDriveTable',
- 'value' => 'pdTemperature',
- 'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36.{{ $index }}',
- 'index' => 'slot.{{ $index }}',
- 'group' => 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId }}',
- 'descr' => '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber }}',
- ),
- ),
- )
- Data adapterPropertiesTable:
- array (
- )
- Data bbuTable:
- array (
- )
- Data physicalDriveTable:
- array (
- )
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",8,"snmp"][0m 1.93ms]
- Tv_signal: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",8,"snmp"][0m 1.46ms]
- Bitrate: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["bitrate",8,"snmp"][0m 1.14ms]
- Voltage: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' '-r' '4' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.3'[0m]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- Invalid snmp_walk() data = .1.3.6.1.4.1.10876.2.1.1.1.1.3 No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",8,"snmp"][0m 2.16ms]
- Snr: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",8,"snmp"][0m 1.79ms]
- Pressure: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",8,"snmp"][0m 0.6ms]
- Cooling: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",8,"snmp"][0m 0.59ms]
- Delay: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",8,"snmp"][0m 0.59ms]
- Quality_factor: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",8,"snmp"][0m 0.57ms]
- Chromatic_dispersion: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",8,"snmp"][0m 0.56ms]
- Ber: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",8,"snmp"][0m 0.79ms]
- Eer: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",8,"snmp"][0m 0.56ms]
- Waterflow: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",8,"snmp"][0m 0.56ms]
- Percent: array (
- )
- SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",8,"snmp"][0m 0.56ms]
- >> Runtime for discovery module 'sensors': 1.4060 seconds with 167672 bytes
- >> [0;36mSNMP[0m: [15/1.35s] [1;33mMySQL[0m: [34/0.30s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module storage ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/datadomain' '-r' '4' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m]
- fileSystemSpaceTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = fileSystemSpaceTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'ARICENT-ISS-MIB::issSwitchCurrentFlashUsage.0'[0m]
- Exitcode: 1 ["MIB search path: /opt/librenms/mibs
- Cannot find module (ARICENT-ISS-MIB): At line 1 in (none)
- ARICENT-ISS-MIB::issSwitchCurrentFlashUsage.0: Unknown Object Identifier
- "]
- MIB search path: /opt/librenms/mibs
- Cannot find module (ARICENT-ISS-MIB): At line 1 in (none)
- ARICENT-ISS-MIB::issSwitchCurrentFlashUsage.0: Unknown Object Identifier
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CPQHOST-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hp' '-r' '4' 'udp:HOSTNAME:161' 'cpqHoFileSysEntry'[0m]
- cpqHoFileSysEntry = No Such Object available on this agent at this OID
- HPE ILO4 hrStorage : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'dskTable'[0m]
- dskTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '8' AND `storage_type` != 'dsk' [0;33m[][0m 0.58ms]
- array (
- )
- SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '8' [0;33m[][0m 0.52ms]
- >> Runtime for discovery module 'storage': 0.2410 seconds with 19536 bytes
- >> [0;36mSNMP[0m: [3/0.17s] [1;33mMySQL[0m: [2/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+
- OS
- Device
- #### Load disco module hr-device ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'hrProcessorTable'[0m]
- hrProcessorTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = hrProcessorTable = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'hrDeviceTable'[0m]
- hrDeviceTable = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = hrDeviceTable = No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '8' [0;33m[][0m 1.17ms]
- >> Runtime for discovery module 'hr-device': 0.1400 seconds with 3648 bytes
- >> [0;36mSNMP[0m: [2/0.14s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+
- OS
- Device
- #### Load disco module discovery-protocols ####
- LLDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'LLDP-MIB::lldpRemTable'[0m]
- lldpRemTable = No Such Object available on this agent at this OID
- OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[8][0m 0.61ms]
- SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[8][0m 0.66ms]
- SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.61ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0480 seconds with 8344 bytes
- >> [0;36mSNMP[0m: [1/0.04s] [1;33mMySQL[0m: [3/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+
- OS
- Device
- #### Load disco module arp-table ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress'[0m]
- IP-MIB::ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-r' '4' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress'[0m]
- IP-MIB::ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
- SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[8,""][0m 2.01ms]
- SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 3.96ms]
- >> Runtime for discovery module 'arp-table': 0.0750 seconds with 3672 bytes
- >> [0;36mSNMP[0m: [2/0.07s] [1;33mMySQL[0m: [2/0.06s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global+
- OS
- Device
- #### Load disco module discovery-arp ####
- SQL[[1;33m
- SELECT *
- FROM ipv4_mac as m, ports as i
- WHERE m.port_id = i.port_id
- AND i.device_id = ?
- AND i.deleted = 0
- AND NOT EXISTS (
- SELECT * FROM ipv4_addresses a
- WHERE a.ipv4_address = m.ipv4_address
- )
- GROUP BY ipv4_address
- ORDER BY ipv4_address
- [0;33m[8][0m 1.46ms]
- >> Runtime for discovery module 'discovery-arp': 0.0020 seconds with 1296 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module discovery-arp ####
- Modules status: Global-
- OS
- Device
- Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+
- OS-
- Device
- Module [ bgp-peers ] disabled on os.
- Modules status: Global+
- OS
- Device
- #### Load disco module vlans ####
- SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[8][0m 0.54ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.1060 seconds with 38896 bytes
- >> [0;36mSNMP[0m: [2/0.10s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global-
- OS+
- Device
- #### Load disco module vminfo ####
- LibVirt VM: not configured
- VMware VM: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-Os' '-r' '4' 'udp:HOSTNAME:161' 'VMWARE-VMINFO-MIB::vmwVmTable'[0m]
- Exitcode: 1 ["MIB search path: /opt/librenms/mibs
- Cannot find module (VMWARE-VMINFO-MIB): At line 1 in (none)
- VMWARE-VMINFO-MIB::vmwVmTable: Unknown Object Identifier
- "]
- MIB search path: /opt/librenms/mibs
- Cannot find module (VMWARE-VMINFO-MIB): At line 1 in (none)
- VMWARE-VMINFO-MIB::vmwVmTable: Unknown Object Identifier
- SNMP query failed. Exit Code: 1 Empty: true Bad String: not found
- SQL[[1;33mselect * from `vminfo` where `vminfo`.`device_id` = ? and `vminfo`.`device_id` is not null [0;33m[8][0m 0.75ms]
- >> Runtime for discovery module 'vminfo': 0.0350 seconds with 13120 bytes
- >> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module vminfo ####
- Modules status: Global+
- OS
- Device
- #### Load disco module printer-supplies ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'Printer-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'prtMarkerSuppliesLevel'[0m]
- prtMarkerSuppliesLevel = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = prtMarkerSuppliesLevel = No Such Object available on this agent at this OID
- Tray Paper Level: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'Printer-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'prtInputName'[0m]
- prtInputName = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = prtInputName = No Such Object available on this agent at this OID
- SQL[[1;33mselect * from `printer_supplies` where `printer_supplies`.`device_id` = ? and `printer_supplies`.`device_id` is not null [0;33m[8][0m 0.63ms]
- >> Runtime for discovery module 'printer-supplies': 0.1470 seconds with 68784 bytes
- >> [0;36mSNMP[0m: [2/0.14s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module printer-supplies ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'diskIOEntry'[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID
- array (
- )
- SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '8' [0;33m[][0m 1.3ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0690 seconds with 2184 bytes
- >> [0;36mSNMP[0m: [1/0.07s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global+
- OS+
- Device
- #### Load disco module applications ####
- Applications: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'nsExtendStatus'[0m]
- nsExtendStatus = No Such Object available on this agent at this OID
- Invalid snmp_walk() data = nsExtendStatus = No Such Object available on this agent at this OID
- Available:
- Checking for:
- SQL[[1;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`=? AND deleted_at IS NULL ORDER BY `app_type` [0;33m[8][0m 1.37ms]
- SQL[[1;33mselect * from `applications` where `applications`.`device_id` = ? and `applications`.`device_id` is not null and 0 = 1 and `applications`.`deleted_at` is null [0;33m[8][0m 0.37ms]
- SQL[[1;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL [0;33m[][0m 0.35ms]
- >> Runtime for discovery module 'applications': 0.0760 seconds with 69800 bytes
- >> [0;36mSNMP[0m: [1/0.07s] [1;33mMySQL[0m: [3/0.02s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module applications ####
- Modules status: Global+
- OS
- Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 648 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+
- OS-
- Device
- Module [ stp ] disabled on os.
- Modules status: Global+
- OS
- Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 9.7990 seconds with 232 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global-
- OS
- Device
- Module [ loadbalancers ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ mef ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module wireless ####
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"ap-count"][0m 0.51ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"clients"][0m 0.43ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"quality"][0m 0.43ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"capacity"][0m 0.42ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"utilization"][0m 0.4ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"rate"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"ccq"][0m 0.4ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"snr"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"sinr"][0m 0.42ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"rsrp"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"rsrq"][0m 0.42ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"ssr"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"mse"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"xpi"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"rssi"][0m 0.42ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"power"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"noise-floor"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"errors"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"error-ratio"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"error-rate"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"frequency"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"distance"][0m 0.41ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"cell"][0m 0.39ms]
- SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[8,"channel"][0m 0.41ms]
- >> Runtime for discovery module 'wireless': 0.0180 seconds with 205016 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [24/0.10s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+
- OS
- Device
- #### Load disco module fdb-table ####
- SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[8][0m 0.34ms]
- SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[8][0m 0.32ms]
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' '-r' '4' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.1430 seconds with 3904 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [2/0.01s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module fdb-table ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mpls ####
- >> Runtime for discovery module 'mpls': 0.0010 seconds with 38704 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module mpls ####
- Modules status: Global+
- OS
- Device
- #### Load disco module toner ####
- Reporting disabled by user setting
- >> Runtime for discovery module 'toner': 0.0000 seconds with 224 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module toner ####
- Modules status: Global+
- OS
- Device
- #### Load disco module vmware-vminfo ####
- >> Runtime for discovery module 'vmware-vminfo': 5.6980 seconds with 0 bytes
- >> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.00s]
- #### Unload disco module vmware-vminfo ####
- SQL[[1;33mupdate `devices` set `last_discovered_timetaken` = ?, `last_discovered` = NOW() where `device_id` = ? [0;33m[6.125,8][0m 0.79ms]
- Discovered in 6.125 seconds
- ./discovery.php skycontrol 2024-06-19 09:09:47 - 1 devices discovered in 6.390 secs
- [0;36mSNMP[0m [93/4.52s]: Snmpget[52/1.67s] Snmpwalk[41/2.85s]
- [1;33mSQL[0m [96/0.71s]: Select[90/0.63s] Delete[4/0.06s]
- [1/0.01s] Update[1/0.01s]
- [0;32mRRD[0m [0/0.00s]: