- LibreNMS Discovery
- SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 0.72ms]
- SQL[select count(*) as aggregate from `migrations` [] 0.66ms]
- SQL[select version() [] 0.34ms]
- ===========================================
- Component | Version
- --------- | -------
- LibreNMS | 23.9.1-46-g366be4c (2023-10-06T00:11:33+02:00)
- DB Schema | 2023_08_30_105156_add_applications_soft_deleted (259)
- PHP | 8.1.11
- Python | 3.6.8
- Database | MariaDB 10.5.9-MariaDB
- RRDTool | 1.4.8
- SNMP | 5.7.2
- ===========================================
- DEBUG!
- Updating os_def.cache
- SQL[SELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE '10.31.10.45' ORDER BY device_id DESC [] 0.8ms]
- SQL[select * from `devices` where `device_id` = ? limit 1 [261] 1.06ms]
- SQL[select * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [261] 0.41ms]
- 10.31.10.45 261 generic [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' '10.31.10.45'
- response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.64/0.69/0.72
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0']
- SNMPv2-MIB::sysObjectID.0 = SNMPv2-SMI::enterprises.1*.*.*.*.*.*.*.116
- Modules status: Global+
- OS
- Device
- #### Load disco module core ####
- Attempting to initialize OS: generic
- OS initialized: LibreNMS\OS\Generic
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.0']
- .*.*.0 = .*.4.1.1*.*.*.*.*.*.*.116
- .*.*.0 = EPSON 10/100/1000 Ethernet USB Ext. Scan Server
- .*.*.0 =
- | EPSON 10/100/1000 Ethernet USB Ext. Scan Server | .1.3.6.1.4.1.1248.1.1.2.1.3.22.78.101.116.119.111.114.107.32.73.110.116.101.114.102.97.99.101.32.85.110.105.116 |
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/arris' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.1166.1.621.14.2.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.1166.1.621.14.2.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.1166.1.621.14.2.0
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.3.1.2.6.100.105.115.116.114.111']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: NET-SNMP-MIB::netSnmpObjects.3.2.3.1.2.6.100.105.115.116.114.111\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: NET-SNMP-MIB::netSnmpObjects.3.2.3.1.2.6.100.105.115.116.114.111
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/eltek' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.12148.10.2.6.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.12148.10.2.6.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.12148.10.2.6.0
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hikvision' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.39165.1.1.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.39165.1.1.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.39165.1.1.0
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/orvaldi' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.21111.1.1.1.6.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.21111.1.1.1.6.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.21111.1.1.1.6.0
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '1.3.6.1.4.1.4515.1.3.6.1.1.1.2.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.4515.1.3.6.1.1.1.2.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.4515.1.3.6.1.1.1.2.0
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/primekey' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'PRIMEKEY-APPLIANCE-MIB::pkAVersion']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: PRIMEKEY-APPLIANCE-MIB::pkAVersion\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: PRIMEKEY-APPLIANCE-MIB::pkAVersion
- SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/wisi' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.2']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: SNMPv2-SMI::enterprises.7465.20.2.9.1.2.1.3.1.2\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: SNMPv2-SMI::enterprises.7465.20.2.9.1.2.1.3.1.2
- OS: Generic Device (generic)
- Attempting to initialize OS: generic
- OS initialized: LibreNMS\OS\Generic
- >> Runtime for discovery module 'core': 0.4050 seconds with 15224 bytes
- >> SNMP: [9/0.35s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+
- OS
- Device
- #### Load disco module os ####
- Yaml location data:
- SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0']
- SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'sysContact.0']
- Yaml OS data:
- Location:
- Hardware:
- OS Version:
- OS Features:
- Serial:
- >> Runtime for discovery module 'os': 0.0590 seconds with 221208 bytes
- >> SNMP: [4/0.05s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports ####
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifDescr']
- ifDescr.1 = Network Interface Unit Hard Ver.1.00 Firm Ver.2.03
- ifDescr.2 = Network Interface Unit Hard Ver.1.00 Firm Ver.2.03
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifName']
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifAlias']
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifType']
- ifType.1 = ethernetCsmacd
- ifType.2 = softwareLoopback
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifOperStatus']
- ifOperStatus.1 = up
- ifOperStatus.2 = up
- array (
- 1 =>
- array (
- 'ifDescr' => 'Network Interface Unit Hard Ver.1.00 Firm Ver.2.03',
- 'ifType' => 'ethernetCsmacd',
- 'ifOperStatus' => 'up',
- ),
- 2 =>
- array (
- 'ifDescr' => 'Network Interface Unit Hard Ver.1.00 Firm Ver.2.03',
- 'ifType' => 'softwareLoopback',
- 'ifOperStatus' => 'up',
- ),
- )
- SQL[SELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [261] 1.3ms]
- Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["Network Interface Unit Hard Ver.1.00 Firm Ver.2.03","ethernetCsmacd","up",1,"Network Interface Unit Hard Ver.1.00 Firm Ver.2.03","Network Interface Unit Hard Ver.1.00 Firm Ver.2.03",118935] 0.62ms]
- . Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["Network Interface Unit Hard Ver.1.00 Firm Ver.2.03","softwareLoopback","up",2,"Network Interface Unit Hard Ver.1.00 Firm Ver.2.03","Network Interface Unit Hard Ver.1.00 Firm Ver.2.03",118936] 0.54ms]
- .
- >> Runtime for discovery module 'ports': 0.1900 seconds with 24952 bytes
- >> SNMP: [5/0.18s] MySQL: [3/0.02s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ports-stack ####
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '261' [] 0.62ms]
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifStackStatus']
- >> Runtime for discovery module 'ports-stack': 0.0320 seconds with 1784 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global-
- OS
- Device
- Module [ xdsl ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'entPhysicalEntry']
- MIB search path: /opt/librenms/mibs
- Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 12 in (none)
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = ? [261] 0.93ms]
- >> Runtime for discovery module 'entity-physical': 0.0280 seconds with 11928 bytes
- >> SNMP: [1/0.03s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global-
- OS
- Device
- Module [ entity-state ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ isis ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrProcessorLoad']
- UCD Resources: SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0']
- Exitcode: 2
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: UCD-SNMP-MIB::ssCpuIdle.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: UCD-SNMP-MIB::ssCpuIdle.0
- SQL[SELECT * FROM `processors` WHERE `device_id`=? [261] 0.89ms]
- SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 1.25ms]
- >> Runtime for discovery module 'processors': 0.0900 seconds with 190616 bytes
- >> SNMP: [2/0.08s] MySQL: [2/0.02s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mempools ####
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrStorageTable']
- SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrMemorySize.0']
- 127280
- SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0']
- Exitcode: 2
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memSysAvail.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memCached.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memBuffer.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memAvailReal.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memTotalReal.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memAvailSwap.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memTotalSwap.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memSysAvail.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memCached.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memBuffer.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memAvailReal.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memTotalReal.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memAvailSwap.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: memTotalSwap.0
- SQL[select * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [261] 0.81ms]
- >> Runtime for discovery module 'mempools': 0.1170 seconds with 109152 bytes
- >> SNMP: [2/0.08s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+
- OS
- Device
- #### Load disco module cisco-vrf-lite ####
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = ? [261] 0.7ms]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2552 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global-
- OS
- Device
- Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-pw ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ vrf ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cef ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ slas ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-cbqos ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-otv ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ cisco-qfp ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv4-addresses ####
- SQL[select * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [261] 0.93ms]
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntIfIndex']
- ipAdEntIfIndex.* 1
- SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.31.10.45']
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [261,"1"] 0.68ms]
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [261,"1"] 0.7ms]
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.31.10.0\/24"] 0.7ms]
- SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? ["","10.31.10.0\/24"] 0.75ms]
- sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["10.31.10.0\/24"] 0.66ms]
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["10.31.10.45",24,118935] 0.65ms]
- SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["","10.31.10.45",24,118935] 0.48ms]
- .SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [261] 2.28ms]
- >> Runtime for discovery module 'ipv4-addresses': 0.0870 seconds with 49576 bytes
- >> SNMP: [2/0.07s] MySQL: [9/0.08s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ipv6-addresses ####
- SNMP['/usr/bin/snmpwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUt' 'udp:HOSTNAME:161' 'IP-MIB::ipAddressIfIndex.ipv6']
- SNMP query failed. Exit Code: 0 Empty: true Bad String: not found
- SNMP failed walking IP-MIB::ipAddressIfIndex.ipv6 of IP-MIB::ipAddressIfIndex.ipv6,IP-MIB::ipAddressOrigin.ipv6,IP-MIB::ipAddressPrefix.ipv6 aborting.
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength']
- SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [261] 0.99ms]
- >> Runtime for discovery module 'ipv6-addresses': 0.0780 seconds with 4704 bytes
- >> SNMP: [2/0.08s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global-
- OS
- Device
- Module [ route ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'entPhysicalDescr']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",261,"ipmi"] 2.88ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",261,"ipmi"] 1.18ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",261,"ipmi"] 1.21ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",261,"ipmi"] 1.16ms]
- Airflow: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",261,"snmp"] 1.18ms]
- Current: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",261,"snmp"] 1.21ms]
- Charge: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",261,"snmp"] 1.18ms]
- Dbm: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",261,"snmp"] 1.18ms]
- Fanspeed: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",261,"snmp"] 1.2ms]
- Frequency: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",261,"snmp"] 1.19ms]
- Humidity: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",261,"snmp"] 1.17ms]
- Load: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",261,"snmp"] 1.2ms]
- Loss: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["loss",261,"snmp"] 1.21ms]
- Power: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",261,"snmp"] 1.16ms]
- Power_consumed: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",261,"snmp"] 1.19ms]
- Power_factor: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",261,"snmp"] 1.33ms]
- Runtime: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",261,"snmp"] 1.13ms]
- Signal: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",261,"snmp"] 1.09ms]
- State: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",261,"snmp"] 1.07ms]
- Count: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",261,"snmp"] 1.13ms]
- Temperature: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",261,"snmp"] 1.09ms]
- Tv_signal: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["tv_signal",261,"snmp"] 1.28ms]
- Bitrate: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["bitrate",261,"snmp"] 1.19ms]
- Voltage: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",261,"snmp"] 1.18ms]
- Snr: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",261,"snmp"] 1.18ms]
- Pressure: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",261,"snmp"] 1.17ms]
- Cooling: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",261,"snmp"] 1.14ms]
- Delay: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",261,"snmp"] 1.1ms]
- Quality_factor: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",261,"snmp"] 1.07ms]
- Chromatic_dispersion: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",261,"snmp"] 1.17ms]
- Ber: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",261,"snmp"] 1.1ms]
- Eer: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",261,"snmp"] 1.13ms]
- Waterflow: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",261,"snmp"] 1.18ms]
- Percent: array (
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["percent",261,"snmp"] 1.25ms]
- >> Runtime for discovery module 'sensors': 0.1010 seconds with 110568 bytes
- >> SNMP: [1/0.04s] MySQL: [34/0.41s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+
- OS
- Device
- #### Load disco module storage ####
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable']
- End of MIB
- hrStorage : SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dskTable']
- End of MIB
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '261' AND `storage_type` != 'dsk' [] 0.86ms]
- array (
- )
- SQL[SELECT * FROM `storage` WHERE `device_id` = '261' [] 0.76ms]
- >> Runtime for discovery module 'storage': 0.0990 seconds with 15200 bytes
- >> SNMP: [2/0.09s] MySQL: [2/0.02s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+
- OS
- Device
- #### Load disco module hr-device ####
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrDeviceTable']
- hrDeviceIndex.1 = 1
- hrDeviceType.1 = hrDeviceOther
- hrDeviceDescr.1 = DS-860
- hrDeviceID.1 = enterprises.1*.*.56.54.48
- hrDeviceStatus.1 = running
- hrDeviceErrors.1 = 0
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrProcessorTable']
- array (
- 1 =>
- array (
- 'hrDeviceIndex' => '1',
- 'hrDeviceType' => 'hrDeviceOther',
- 'hrDeviceDescr' => 'DS-860',
- 'hrDeviceID' => 'enterprises.1248.1.2.1.6.68.83.45.56.54.48',
- 'hrDeviceStatus' => 'running',
- 'hrDeviceErrors' => '0',
- ),
- )
- SQL[SELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [261,"1"] 0.8ms]
- SQL[UPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? ["hrDeviceOther","DS-860","running","0",261,"1"] 0.57ms]
- .SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '261' [] 0.63ms]
- >> Runtime for discovery module 'hr-device': 0.0670 seconds with 9768 bytes
- >> SNMP: [2/0.06s] MySQL: [3/0.02s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+
- OS
- Device
- #### Load disco module discovery-protocols ####
- LLDP-MIB: SNMP['/usr/bin/snmpwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' '-Os' 'udp:HOSTNAME:161' 'LLDP-MIB::lldpRemTable']
- OSPF Discovery: SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [261] 0.8ms]
- SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [261] 1.27ms]
- SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 0.9ms]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0580 seconds with 8160 bytes
- >> SNMP: [1/0.05s] MySQL: [3/0.03s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+
- OS
- Device
- #### Load disco module arp-table ####
- SNMP['/usr/bin/snmpwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToPhysicalPhysAddress']
- SNMP['/usr/bin/snmpwalk' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'IP-MIB::ipNetToMediaPhysAddress']
- IP-MIB::ipNetToMediaPhysAddress[1][*] = c4:64:13:dc:8e:60
- SQL[SELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [261,""] 6.09ms]
- SQL[SELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [261,1] 1.27ms]
- Network Interface Unit Hard Ver.1.00 Firm Ver.2.03:
- c4:64:13:dc:8e:60 => 10.31.10.250
- Reporting disabled by user setting
- SQL[DELETE FROM `ipv4_mac` WHERE `port_id` = ? AND `mac_address`=? AND `ipv4_address`=? AND `context_name`=? [118935,"d8bbc1eaacdc","10.31.10.10",""] 1.18ms]
- SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [] 12.57ms]
- >> Runtime for discovery module 'arp-table': 0.1250 seconds with 15776 bytes
- >> SNMP: [2/0.10s] MySQL: [4/0.21s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global+
- OS
- Device
- #### Load disco module discovery-arp ####
- SQL[
- SELECT *
- FROM ipv4_mac as m, ports as i
- WHERE m.port_id = i.port_id
- AND i.device_id = ?
- AND i.deleted = 0
- AND NOT EXISTS (
- SELECT * FROM ipv4_addresses a
- WHERE a.ipv4_address = m.ipv4_address
- )
- GROUP BY ipv4_address
- ORDER BY ipv4_address
- [261] 2.33ms]
- >> Runtime for discovery module 'discovery-arp': 0.0030 seconds with 1288 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.02s] RRD: [0/0.00s]
- #### Unload disco module discovery-arp ####
- Modules status: Global-
- OS
- Device
- Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module bgp-peers ####
- SNMP['/usr/bin/snmpgetnext' '-v1' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'bgpLocalAs']
- 0:0:58:24.00
- No BGP on hostPeers :
- SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [261,""] 0.56ms]
- SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [261,""] 0.49ms]
- SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [261] 0.62ms]
- >> Runtime for discovery module 'bgp-peers': 0.0340 seconds with 4712 bytes
- >> SNMP: [1/0.03s] MySQL: [3/0.02s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+
- OS
- Device
- #### Load disco module vlans ####
- SQL[SELECT * FROM `vlans` WHERE `device_id` = ? [261] 0.77ms]
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex']
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP['/usr/bin/snmpget' '-v1' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0']
- Exitcode: 2
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: Q-BRIDGE-MIB::dot1qVlanVersionNumber.0
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: Q-BRIDGE-MIB::dot1qVlanVersionNumber.0
- >> Runtime for discovery module 'vlans': 0.0890 seconds with 6384 bytes
- >> SNMP: [2/0.09s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global-
- OS
- Device
- Module [ vmware-vminfo ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ libvirt-vminfo ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ printer-supplies ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module ucd-diskio ####
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'diskIOEntry']
- End of MIB
- array (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '261' [] 0.78ms]
- >> Runtime for discovery module 'ucd-diskio': 0.0350 seconds with 1784 bytes
- >> SNMP: [1/0.03s] MySQL: [1/0.01s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global-
- OS
- Device
- Module [ applications ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 688 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+
- OS
- Device
- #### Load disco module stp ####
- Instances: SNMP['/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-m' 'SNMPv2-TC:SNMPv2-MIB:IF-MIB:IP-MIB:TCP-MIB:UDP-MIB:NET-SNMP-VACM-MIB' '-v1' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'BRIDGE-MIB::dot1dStpProtocolSpecification.0']
- Exitcode: 2 ["Error in packet\nReason: (noSuchName) There is no such variable name in this MIB.\nFailed object: BRIDGE-MIB::dot1dStpProtocolSpecification.0\n\n"]
- Error in packet
- Reason: (noSuchName) There is no such variable name in this MIB.
- Failed object: BRIDGE-MIB::dot1dStpProtocolSpecification.0
- SQL[select * from `stp` where `stp`.`device_id` = ? and `stp`.`device_id` is not null [261] 0.92ms]
- Ports: SQL[select * from `ports_stp` where `ports_stp`.`device_id` = ? and `ports_stp`.`device_id` is not null [261] 0.79ms]
- >> Runtime for discovery module 'stp': 0.0440 seconds with 76416 bytes
- >> SNMP: [1/0.04s] MySQL: [2/0.02s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+
- OS
- Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global-
- OS
- Device
- Module [ loadbalancers ] disabled globally.
- Modules status: Global-
- OS
- Device
- Module [ mef ] disabled globally.
- Modules status: Global+
- OS
- Device
- #### Load disco module wireless ####
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"ap-count"] 0.95ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"clients"] 0.75ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"quality"] 0.8ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"capacity"] 0.78ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"utilization"] 0.79ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"rate"] 1.43ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"ccq"] 0.74ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"snr"] 0.78ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"sinr"] 0.76ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"rsrp"] 0.72ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"rsrq"] 0.74ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"ssr"] 0.76ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"mse"] 0.74ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"xpi"] 0.73ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"rssi"] 0.72ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"power"] 0.76ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"noise-floor"] 0.75ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"errors"] 0.74ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"error-ratio"] 0.72ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"error-rate"] 0.74ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"frequency"] 0.76ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"distance"] 0.76ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"cell"] 0.72ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [261,"channel"] 0.71ms]
- >> Runtime for discovery module 'wireless': 0.0330 seconds with 207792 bytes
- >> SNMP: [0/0.00s] MySQL: [24/0.19s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+
- OS
- Device
- #### Load disco module fdb-table ####
- SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [261] 0.61ms]
- SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = ? [261] 0.7ms]
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qTpFdbPort']
- SNMP['/usr/bin/snmpwalk' '-v1' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dTpFdbPort']
- >> Runtime for discovery module 'fdb-table': 0.0740 seconds with 3288 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.01s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- Modules status: Global+
- OS
- Device
- #### Load disco module mpls ####
- >> Runtime for discovery module 'mpls': 0.0010 seconds with 39216 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module mpls ####
- SQL[update `devices` set `last_discovered_timetaken` = ?, `last_discovered` = NOW() where `device_id` = ? [2.955,261] 0.89ms]
- Discovered in 2.955 seconds
- ./discovery.php 10.31.10.45 2023-10-06 13:12:57 - 1 devices discovered in 3.308 secs
- SNMP [41/1.50s]: Snmpget[20/0.69s] Snmpwalk[20/0.78s] Snmpgetnext[1/0.03s]
- SQL [107/1.19s]: Select[94/0.95s] Update[6/0.04s] Delete[6/0.17s]
- [1/0.02s]
- RRD [0/0.00s]: