- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: db3a0c26232494c7f3efc13ac71d801af7ba7898
- Commit Date: 1495281598
- DB Schema: 192
- PHP: 7.0.14
- MySQL: 5.5.52-MariaDB
- RRDTool: 1.4.8
- SNMP: NET-SNMP 5.7.2
- ==================================DEBUG!
- DB Schema update started....
- SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1]
- DB Schema already up to date.
- SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE '10.175.200.10' ORDER BY device_id DESC]
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '120']
- 10.175.200.10 120 generic SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.93','1.01','0.97','120',NOW())]
- SNMP Check response code: 0
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- Schneider Electric - PM850SD
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.38*.15
- | Schneider Electric - PM850SD | .1.3.6.1.4.1.3833.1.7.255.15 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 SML-MIB::product-Name.0]
- Wrong Type (should be OCTET STRING): NULL
- Modules status: Global+ OS Device
- #### Load disco module os ####
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- Schneider Electric - PM850SD
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.38*.15
- | Schneider Electric - PM850SD | .1.3.6.1.4.1.3833.1.7.255.15 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 SML-MIB::product-Name.0]
- Wrong Type (should be OCTET STRING): NULL
- >> Runtime for discovery module 'os': 0.3040 seconds with 1168 bytes
- #### Unload disco module os ####
- Modules status: Global+ OS Device
- #### Load disco module ports ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr]
- ifDescr.1 = lo
- ifDescr.2 = eth0
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName]
- ifName = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias]
- ifAlias = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType]
- ifType.1 = other
- ifType.2 = iso88023Csmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => lo
- [ifType] => other
- )
- [2] => Array
- (
- [ifDescr] => eth0
- [ifType] => iso88023Csmacd
- )
- )
- SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '120' ORDER BY port_id]
- ..
- >> Runtime for discovery module 'ports': 0.1710 seconds with 2008 bytes
- #### Unload disco module ports ####
- Modules status: Global+ OS Device
- #### Load disco module ports-stack ####
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '120']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus]
- ifStackStatus = NULL
- >> Runtime for discovery module 'ports-stack': 0.0740 seconds with 640 bytes
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry]
- entPhysicalEntry = NULL
- entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier]
- entAliasMappingIdentifier = NULL
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '120']
- >> Runtime for discovery module 'entity-physical': 0.1230 seconds with 14192 bytes
- #### Unload disco module entity-physical ####
- Modules status: Global+ OS Device
- #### Load disco module processors ####
- hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDevice]
- hrDevice = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad]
- hrProcessorLoad = NULL
- SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '120' AND `processor_type` != 'ucd-old']
- SQL[SELECT * FROM `processors` WHERE `device_id` = '120']
- >> Runtime for discovery module 'processors': 0.1220 seconds with 32160 bytes
- #### Unload disco module processors ####
- Modules status: Global+ OS Device
- #### Load disco module mempools ####
- SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '120' AND `mempool_type` = 'cemp']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal]
- hpLocalMem = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal]
- hpGlobalMem = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = NULL
- SQL[SELECT * FROM `mempools` WHERE `device_id` = '120']
- >> Runtime for discovery module 'mempools': 0.1720 seconds with 15200 bytes
- #### Unload disco module mempools ####
- Modules status: Global+ OS Device
- #### Load disco module cisco-vrf-lite ####
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '120' ]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1544 bytes
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-pw ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cef ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-sla ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally.
- Modules status: Global- OS Device Module [ cisco-otv ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module ipv4-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex]
- ipAdEntIfIndex.* 2
- ipAdEntIfIndex.* 1
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.10.175.200.10]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '120' AND `ifIndex` = '2']
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '120' AND `ifIndex` = '2']
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.0/8']
- SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '10.0.0.0/8']
- sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.0/8']
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '10.175.200.10' AND `ipv4_prefixlen` = '8' AND `port_id` = '3026' ]
- SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '10.175.200.10' AND `ipv4_prefixlen` = '8' AND `port_id` = '3026']
- .SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '120' AND `ifIndex` = '1']
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '120' AND `ifIndex` = '1']
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
- SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.0/8']
- sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8']
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '3025' ]
- SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '3025']
- .SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '120' OR `ports`.`device_id` IS NULL]
- >> Runtime for discovery module 'ipv4-addresses': 0.1280 seconds with 4656 bytes
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS Device
- #### Load disco module ipv6-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
- ipAddressIfIndex.ipv6 Wrong Type (should be INTEGER): NULL
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.4.34.1.5.2.16.2917072358]
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.4.34.1.6.2.16.2917072358]
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '120' AND `ifIndex` = 'Wrong']
- SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '120' OR `ports`.`device_id` IS NULL]
- >> Runtime for discovery module 'ipv6-addresses': 0.1020 seconds with 6928 bytes
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS Device Module [ route ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr]
- entPhysicalDescr = NULL
- entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName]
- entPhysicalName = NULL
- entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType]
- entPhySensorType = NULL
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale]
- entPhySensorScale = NULL
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision]
- entPhySensorPrecision = NULL
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue]
- entPhySensorValue = NULL
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '120' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'ipmi']
- Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '120' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 0.3200 seconds with 7504 bytes
- #### Unload disco module sensors ####
- Modules status: Global+ OS Device
- #### Load disco module storage ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry]
- eqliscsiVolumeEntry = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dfEntry]
- dfEntry = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable]
- dskTable = NULL
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '120' AND `storage_type` != 'dsk']
- SQL[SELECT * FROM `storage` WHERE `device_id` = '120']
- >> Runtime for discovery module 'storage': 0.2560 seconds with 3232 bytes
- #### Unload disco module storage ####
- Modules status: Global+ OS Device
- #### Load disco module hr-device ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry]
- hrDeviceEntry = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry]
- hrProcessorEntry = NULL
- Array
- (
- )
- SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '120']
- >> Runtime for discovery module 'hr-device': 0.1050 seconds with 792 bytes
- #### Unload disco module hr-device ####
- Modules status: Global+ OS Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache]
- cdpCache = NULL
- Array
- (
- )
- LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemoteSystemsData]
- lldpRemoteSystemsData = NULL
- lldpRemoteSystemsData = NULL || lldpRemoteSystemsData || || ||
- Array
- (
- )
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex]
- dot1dBasePortIfIndex = NULL
- Array
- (
- )
- OSPF Discovery: enabled
- SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='120']
- SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '120']
- >> Runtime for discovery module 'discovery-protocols': 0.3350 seconds with 4208 bytes
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS Device
- #### Load disco module arp-table ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
- ipNetToPhysicalPhysAddress = NULL
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress]
- ipNetToMediaPhysAddress.*.1 = 0:f:24:bf:74:cc
- ipNetToMediaPhysAddress.*.2 = 0:21:9b:8b:e7:f
- ipNetToMediaPhysAddress.*.253 = 0:c:29:92:c:ae
- ipNetToMediaPhysAddress.*.42 = 0:21:9b:8b:e7:f
- SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='120' AND M.context_name='']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '120' AND `ifIndex` = '2']
- SQL[DELETE `ipv4_mac` FROM `ipv4_mac` LEFT JOIN `ports`
- ON `ipv4_mac`.`port_id` = `ports`.`port_id` WHERE `ports`.`port_id` IS NULL]
- >> Runtime for discovery module 'arp-table': 0.1370 seconds with 17016 bytes
- #### Unload disco module arp-table ####
- Modules status: Global- OS Device Module [ discovery-arp ] disabled globally.
- Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module bgp-peers ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.15.2]
- Wrong Type (should be INTEGER): NULL
- No BGP on hostPeers :
- SQL[SELECT * FROM bgpPeers WHERE device_id = '120' AND (context_name = '' OR context_name IS NULL)]
- >> Runtime for discovery module 'bgp-peers': 0.0520 seconds with 2832 bytes
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS Device
- #### Load disco module vlans ####
- SQL[SELECT * FROM `vlans` WHERE `device_id` = '120']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex]
- dot1dBasePortIfIndex = NULL
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0]
- Wrong Type (should be INTEGER): NULL
- >> Runtime for discovery module 'vlans': 0.1020 seconds with 4448 bytes
- #### Unload disco module vlans ####
- Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally.
- Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally.
- Modules status: Global- OS Device Module [ toner ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module ucd-diskio ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry]
- diskIOEntry = NULL
- Array
- (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '120']
- >> Runtime for discovery module 'ucd-diskio': 0.0490 seconds with 736 bytes
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS Device Module [ applications ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
- #### Unload disco module services ####
- Modules status: Global+ OS Device
- #### Load disco module stp ####
- SQL[SELECT * FROM `stp` WHERE `device_id` = '120']
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
- Wrong Type (should be INTEGER): NULL
- >> Runtime for discovery module 'stp': 0.0250 seconds with 3712 bytes
- #### Unload disco module stp ####
- Modules status: Global+ OS Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 144 bytes
- #### Unload disco module ntp ####
- Modules status: Global- OS Device Module [ loadbalancers ] disabled globally.
- Modules status: Global- OS Device Module [ mef ] disabled globally.
- Modules status: Global+ OS Device
- #### Load disco module wireless ####
- Attempting to initialize OS: generic
- OS initialized: LibreNMS\OS\Generic
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='ap-count']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='clients']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='quality']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='capacity']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='utilization']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='rate']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='ccq']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='snr']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='rssi']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='power']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='noise-floor']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='error-ratio']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='error-rate']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='frequency']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='120' AND `sensor_class`='distance']
- >> Runtime for discovery module 'wireless': 0.0120 seconds with 130880 bytes
- #### Unload disco module wireless ####
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '120' AND `attrib_type` = 'poll_mib' ]
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='3.370' WHERE `device_id` = '120']
- Discovered in 3.370 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','10.175.200.10','1495464651.0483','3.419','1','theia.turnkeyinternet.net\n')]
- /opt/librenms/discovery.php 10.175.200.10 2017-05-22 10:50:54 - 1 devices discovered in 3.419 secs
- SNMP: Get[13/0.51s] Walk [30/1.72s]
- MySQL: Cell[16/0.01s] Row[5/0.00s] Rows[53/0.04s] Column[1/0.00s] Update[5/0.01s] Insert[2/0.00s] Delete[0/0.00s]