From Blush Bushbaby, 5 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. ===================================
  3. Version info:
  4. Commit SHA: 0020479fc858a5b6c6204fee6100afa1c09f56f8
  5. Commit Date: 1525873161
  6. DB Schema: 249
  7. PHP: 7.2.5
  8. MySQL: 5.7.21-21
  9. RRDTool: 1.6.0
  10. SNMP: NET-SNMP 5.7.2
  11. ==================================DEBUG!
  12. Updating os_def.cache... Done
  13. SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `device_id` = '39' ORDER BY device_id DESC[0m]
  14. SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '39'[0m]
  15. acme01 39 acmepacket SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','0.16','0.17','0.16','39',NOW())[0m]
  16. SNMP Check response code: 0
  17. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
  18. Attempting to initialize OS: acmepacket
  19. OS initilized as Generic
  20.  
  21. Modules status: Global+ OS  Device  
  22. #### Load disco module core ####
  23. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
  24. .*.*.0 = acme01
  25. .*.*.0 = .*.4.1.9*
  26. .*.*.0 = Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
  27.  
  28.  
  29. >> Runtime for discovery module 'core': 0.0120 seconds with 1088 bytes
  30. >> SNMP: [2/0.32s] MySQL: [6/0.00s] RRD: [0/0.00s]
  31. #### Unload disco module core ####
  32.  
  33. Modules status: Global+ OS+ Device  
  34. #### Load disco module os ####
  35. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
  36. Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578)
  37.  
  38. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
  39. .*.4.1.9*
  40.  
  41. | Acme Packet Net-Net 4500 SCX6.4.0 MR-6 Patch 2 (Build 578) | .1.3.6.1.4.1.9148.1.1.2 |
  42. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m]
  43. No Such Object available on this agent at this OID
  44.  
  45. SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','NULL','system',NOW(),'3','Device OS changed acmepacket => generic','')[0m]
  46. SQL[[0;33mUPDATE `devices` set `os` ='generic' WHERE device_id='39'[0m]
  47. SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','NULL','system',NOW(),'3','Device type changed  => server','')[0m]
  48. SQL[[0;33mUPDATE `devices` set `type` ='server' WHERE device_id='39'[0m]
  49. Device type changed to server!
  50. Attempting to initialize OS: generic
  51. OS initialized: LibreNMS\OS\Generic
  52. Changed OS: Generic Device (generic)
  53.  
  54. >> Runtime for discovery module 'os': 0.9220 seconds with 5952 bytes
  55. >> SNMP: [3/0.92s] MySQL: [4/0.00s] RRD: [0/0.00s]
  56. #### Unload disco module os ####
  57.  
  58. Modules status: Global+ OS+ Device  
  59. #### Load disco module ports ####
  60. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr[0m]
  61. ifDescr.1 = eth0 ETH
  62. ifDescr.2 = lo0
  63. ifDescr.5 = M0 GE
  64. ifDescr.6 = GE
  65. ifDescr.7 = M1 GE
  66. ifDescr.8 = GE
  67. ifDescr.13 = sp0 ETH
  68.  
  69. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName[0m]
  70. ifName.5 = M0
  71. ifName.6 =
  72. ifName.7 = M1
  73. ifName.8 =
  74.  
  75. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias[0m]
  76. ifAlias.5 =
  77. ifAlias.6 =
  78. ifAlias.7 =
  79. ifAlias.8 =
  80.  
  81. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType[0m]
  82. ifType.1 = ethernetCsmacd
  83. ifType.2 = softwareLoopback
  84. ifType.5 = gigabitEthernet
  85. ifType.6 = gigabitEthernet
  86. ifType.7 = gigabitEthernet
  87. ifType.8 = gigabitEthernet
  88. ifType.13 = ethernetCsmacd
  89.  
  90. Array
  91. (
  92.     [1] => Array
  93.         (
  94.             [ifDescr] => eth0 ETH
  95.             [ifType] => ethernetCsmacd
  96.         )
  97.  
  98.     [2] => Array
  99.         (
  100.             [ifDescr] => lo0
  101.             [ifType] => softwareLoopback
  102.         )
  103.  
  104.     [5] => Array
  105.         (
  106.             [ifDescr] => M0 GE
  107.             [ifName] => M0
  108.             [ifAlias] =>
  109.             [ifType] => gigabitEthernet
  110.         )
  111.  
  112.     [6] => Array
  113.         (
  114.             [ifDescr] => GE
  115.             [ifName] =>
  116.             [ifAlias] =>
  117.             [ifType] => gigabitEthernet
  118.         )
  119.  
  120.     [7] => Array
  121.         (
  122.             [ifDescr] => M1 GE
  123.             [ifName] => M1
  124.             [ifAlias] =>
  125.             [ifType] => gigabitEthernet
  126.         )
  127.  
  128.     [8] => Array
  129.         (
  130.             [ifDescr] => GE
  131.             [ifName] =>
  132.             [ifAlias] =>
  133.             [ifType] => gigabitEthernet
  134.         )
  135.  
  136.     [13] => Array
  137.         (
  138.             [ifDescr] => sp0 ETH
  139.             [ifType] => ethernetCsmacd
  140.         )
  141.  
  142. )
  143. SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m]
  144. SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '39' ORDER BY port_id[0m]
  145. .......
  146.  
  147. >> Runtime for discovery module 'ports': 0.0790 seconds with 4248 bytes
  148. >> SNMP: [4/0.08s] MySQL: [2/0.00s] RRD: [0/0.00s]
  149. #### Unload disco module ports ####
  150.  
  151. Modules status: Global+ OS+ Device  
  152. #### Load disco module ports-stack ####
  153. SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '39'[0m]
  154. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus[0m]
  155. ifStackStatus = No Such Object available on this agent at this OID
  156.  
  157.  
  158.  
  159. >> Runtime for discovery module 'ports-stack': 0.0240 seconds with 1768 bytes
  160. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  161. #### Unload disco module ports-stack ####
  162.  
  163. Modules status: Global+ OS+ Device  
  164. #### Load disco module entity-physical ####
  165.  
  166. Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry[0m]
  167. entPhysicalDescr.1 = Assy, NetNet4500
  168. entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
  169. entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
  170. entPhysicalDescr.4 = Assy, 4-fan unit
  171. entPhysicalDescr.5 = PHY Slot
  172. entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
  173. entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
  174. entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
  175. entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
  176. entPhysicalDescr.10 = Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
  177. entPhysicalDescr.11 = Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
  178. entPhysicalDescr.12 = Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
  179. entPhysicalDescr.13 = Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
  180. entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
  181. entPhysicalDescr.19 = TLS Hardware Accelerator
  182. entPhysicalVendorType.1 = enterprises.9*.3.2.5
  183. entPhysicalVendorType.2 = enterprises.9*.5.3
  184. entPhysicalVendorType.3 = enterprises.9*.5.3
  185. entPhysicalVendorType.4 = enterprises.9*.6.3
  186. entPhysicalVendorType.5 = enterprises.9*.4.2.2
  187. entPhysicalVendorType.6 = enterprises.9*.8.2.12
  188. entPhysicalVendorType.7 = enterprises.9*.9.3
  189. entPhysicalVendorType.8 = enterprises.9*.9.3
  190. entPhysicalVendorType.9 = enterprises.9*.9.3
  191. entPhysicalVendorType.10 = enterprises.9*.9.2
  192. entPhysicalVendorType.11 = enterprises.9*.9.2
  193. entPhysicalVendorType.12 = enterprises.9*.9.2
  194. entPhysicalVendorType.13 = enterprises.9*.9.2
  195. entPhysicalVendorType.18 = enterprises.9*.8.4.7
  196. entPhysicalVendorType.19 = enterprises.9*.8.8.6
  197. entPhysicalContainedIn.1 = 0
  198. entPhysicalContainedIn.2 = 1
  199. entPhysicalContainedIn.3 = 1
  200. entPhysicalContainedIn.4 = 1
  201. entPhysicalContainedIn.5 = 1
  202. entPhysicalContainedIn.6 = 5
  203. entPhysicalContainedIn.7 = 6
  204. entPhysicalContainedIn.8 = 6
  205. entPhysicalContainedIn.9 = 6
  206. entPhysicalContainedIn.10 = 6
  207. entPhysicalContainedIn.11 = 6
  208. entPhysicalContainedIn.12 = 6
  209. entPhysicalContainedIn.13 = 6
  210. entPhysicalContainedIn.18 = 1
  211. entPhysicalContainedIn.19 = 1
  212. entPhysicalClass.1 = chassis
  213. entPhysicalClass.2 = powerSupply
  214. entPhysicalClass.3 = powerSupply
  215. entPhysicalClass.4 = fan
  216. entPhysicalClass.5 = container
  217. entPhysicalClass.6 = module
  218. entPhysicalClass.7 = port
  219. entPhysicalClass.8 = port
  220. entPhysicalClass.9 = port
  221. entPhysicalClass.10 = port
  222. entPhysicalClass.11 = port
  223. entPhysicalClass.12 = port
  224. entPhysicalClass.13 = port
  225. entPhysicalClass.18 = module
  226. entPhysicalClass.19 = module
  227. entPhysicalParentRelPos.1 = 0
  228. entPhysicalParentRelPos.2 = 1
  229. entPhysicalParentRelPos.3 = 2
  230. entPhysicalParentRelPos.4 = 3
  231. entPhysicalParentRelPos.5 = 4
  232. entPhysicalParentRelPos.6 = 1
  233. entPhysicalParentRelPos.7 = 1
  234. entPhysicalParentRelPos.8 = 2
  235. entPhysicalParentRelPos.9 = 3
  236. entPhysicalParentRelPos.10 = 1
  237. entPhysicalParentRelPos.11 = 2
  238. entPhysicalParentRelPos.12 = 3
  239. entPhysicalParentRelPos.13 = 4
  240. entPhysicalParentRelPos.18 = 5
  241. entPhysicalParentRelPos.19 = 7
  242. entPhysicalName.1 = Main Board
  243. entPhysicalName.2 = Power Supply A
  244. entPhysicalName.3 = Power Supply B
  245. entPhysicalName.4 = 4-Fan unit
  246. entPhysicalName.5 = PHY Slot
  247. entPhysicalName.6 = Quad port GiGE SFP PHY
  248. entPhysicalName.7 = Mgmt0
  249. entPhysicalName.8 = Mgmt1
  250. entPhysicalName.9 = Mgmt2
  251. entPhysicalName.10 = M0
  252. entPhysicalName.11 = M1
  253. entPhysicalName.12 =
  254. entPhysicalName.13 =
  255. entPhysicalName.18 = Host CPU Processor
  256. entPhysicalName.19 = BCM5823
  257. entPhysicalHardwareRev.1 = 5.10
  258. entPhysicalHardwareRev.2 =
  259. entPhysicalHardwareRev.3 =
  260. entPhysicalHardwareRev.4 =
  261. entPhysicalHardwareRev.5 =
  262. entPhysicalHardwareRev.6 = 4.11
  263. entPhysicalHardwareRev.7 =
  264. entPhysicalHardwareRev.8 =
  265. entPhysicalHardwareRev.9 =
  266. entPhysicalHardwareRev.10 =
  267. entPhysicalHardwareRev.11 =
  268. entPhysicalHardwareRev.12 =
  269. entPhysicalHardwareRev.13 =
  270. entPhysicalHardwareRev.18 =
  271. entPhysicalHardwareRev.19 = 1
  272. entPhysicalFirmwareRev.1 =
  273. entPhysicalFirmwareRev.2 =
  274. entPhysicalFirmwareRev.3 =
  275. entPhysicalFirmwareRev.4 =
  276. entPhysicalFirmwareRev.5 =
  277. entPhysicalFirmwareRev.6 =
  278. entPhysicalFirmwareRev.7 =
  279. entPhysicalFirmwareRev.8 =
  280. entPhysicalFirmwareRev.9 =
  281. entPhysicalFirmwareRev.10 =
  282. entPhysicalFirmwareRev.11 =
  283. entPhysicalFirmwareRev.12 =
  284. entPhysicalFirmwareRev.13 =
  285. entPhysicalFirmwareRev.18 =
  286. entPhysicalFirmwareRev.19 =
  287. entPhysicalSoftwareRev.1 =
  288. entPhysicalSoftwareRev.2 =
  289. entPhysicalSoftwareRev.3 =
  290. entPhysicalSoftwareRev.4 =
  291. entPhysicalSoftwareRev.5 =
  292. entPhysicalSoftwareRev.6 =
  293. entPhysicalSoftwareRev.7 =
  294. entPhysicalSoftwareRev.8 =
  295. entPhysicalSoftwareRev.9 =
  296. entPhysicalSoftwareRev.10 =
  297. entPhysicalSoftwareRev.11 =
  298. entPhysicalSoftwareRev.12 =
  299. entPhysicalSoftwareRev.13 =
  300. entPhysicalSoftwareRev.18 =
  301. entPhysicalSoftwareRev.19 =
  302. entPhysicalSerialNum.1 = 151330035903
  303. entPhysicalSerialNum.2 =
  304. entPhysicalSerialNum.3 =
  305. entPhysicalSerialNum.4 =
  306. entPhysicalSerialNum.5 =
  307. entPhysicalSerialNum.6 = 091128054782
  308. entPhysicalSerialNum.7 =
  309. entPhysicalSerialNum.8 =
  310. entPhysicalSerialNum.9 =
  311. entPhysicalSerialNum.10 =
  312. entPhysicalSerialNum.11 =
  313. entPhysicalSerialNum.12 =
  314. entPhysicalSerialNum.13 =
  315. entPhysicalSerialNum.18 =
  316. entPhysicalSerialNum.19 =
  317. entPhysicalMfgName.1 = Unknown manufacturer
  318. entPhysicalMfgName.2 =
  319. entPhysicalMfgName.3 =
  320. entPhysicalMfgName.4 =
  321. entPhysicalMfgName.5 =
  322. entPhysicalMfgName.6 = Benchmark Electronics
  323. entPhysicalMfgName.7 =
  324. entPhysicalMfgName.8 =
  325. entPhysicalMfgName.9 =
  326. entPhysicalMfgName.10 =
  327. entPhysicalMfgName.11 =
  328. entPhysicalMfgName.12 =
  329. entPhysicalMfgName.13 =
  330. entPhysicalMfgName.18 =
  331. entPhysicalMfgName.19 = BROADCOM
  332. entPhysicalModelName.1 = 002-0610-50
  333. entPhysicalModelName.2 =
  334. entPhysicalModelName.3 =
  335. entPhysicalModelName.4 =
  336. entPhysicalModelName.5 =
  337. entPhysicalModelName.6 = 002-0613-58
  338. entPhysicalModelName.7 =
  339. entPhysicalModelName.8 =
  340. entPhysicalModelName.9 =
  341. entPhysicalModelName.10 =
  342. entPhysicalModelName.11 =
  343. entPhysicalModelName.12 =
  344. entPhysicalModelName.13 =
  345. entPhysicalModelName.18 =
  346. entPhysicalModelName.19 = BCM5823
  347. entPhysicalAlias.1 =
  348. entPhysicalAlias.2 =
  349. entPhysicalAlias.3 =
  350. entPhysicalAlias.4 =
  351. entPhysicalAlias.5 =
  352. entPhysicalAlias.6 =
  353. entPhysicalAlias.7 =
  354. entPhysicalAlias.8 =
  355. entPhysicalAlias.9 =
  356. entPhysicalAlias.10 =
  357. entPhysicalAlias.11 =
  358. entPhysicalAlias.12 =
  359. entPhysicalAlias.13 =
  360. entPhysicalAlias.18 =
  361. entPhysicalAlias.19 =
  362. entPhysicalAssetID.1 =
  363. entPhysicalAssetID.2 =
  364. entPhysicalAssetID.3 =
  365. entPhysicalAssetID.4 =
  366. entPhysicalAssetID.5 =
  367. entPhysicalAssetID.6 =
  368. entPhysicalAssetID.7 =
  369. entPhysicalAssetID.8 =
  370. entPhysicalAssetID.9 =
  371. entPhysicalAssetID.10 =
  372. entPhysicalAssetID.11 =
  373. entPhysicalAssetID.12 =
  374. entPhysicalAssetID.13 =
  375. entPhysicalAssetID.18 =
  376. entPhysicalAssetID.19 =
  377. entPhysicalIsFRU.1 = false
  378. entPhysicalIsFRU.2 = true
  379. entPhysicalIsFRU.3 = true
  380. entPhysicalIsFRU.4 = true
  381. entPhysicalIsFRU.5 = false
  382. entPhysicalIsFRU.6 = true
  383. entPhysicalIsFRU.7 = false
  384. entPhysicalIsFRU.8 = false
  385. entPhysicalIsFRU.9 = false
  386. entPhysicalIsFRU.10 = true
  387. entPhysicalIsFRU.11 = true
  388. entPhysicalIsFRU.12 = true
  389. entPhysicalIsFRU.13 = true
  390. entPhysicalIsFRU.18 = false
  391. entPhysicalIsFRU.19 = true
  392.  
  393.  entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
  394. entAliasMappingIdentifier = No Such Object available on this agent at this OID
  395.  
  396. SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '1'[0m]
  397. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='Assy, NetNet4500',`entPhysicalClass` ='chassis',`entPhysicalName` ='Main Board',`entPhysicalModelName` ='002-0610-50',`entPhysicalSerialNum` ='151330035903',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Unknown manufacturer',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='enterprises.9148.6.1.1.3.2.5',`entPhysicalHardwareRev` ='5.10',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='1'[0m]
  398. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '2'[0m]
  399. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply A',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='2'[0m]
  400. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '3'[0m]
  401. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='3',`entPhysicalDescr` ='Assy, 300 Watt Power 110V Supply',`entPhysicalClass` ='powerSupply',`entPhysicalName` ='Power Supply B',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.5.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='3'[0m]
  402. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '4'[0m]
  403. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='4',`entPhysicalDescr` ='Assy, 4-fan unit',`entPhysicalClass` ='fan',`entPhysicalName` ='4-Fan unit',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.6.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='4'[0m]
  404. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '5'[0m]
  405. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='5',`entPhysicalDescr` ='PHY Slot',`entPhysicalClass` ='container',`entPhysicalName` ='PHY Slot',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.4.2.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='5'[0m]
  406. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '6'[0m]
  407. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='6',`entPhysicalDescr` ='Assy, 4 Port SFP with QOS and IPSec',`entPhysicalClass` ='module',`entPhysicalName` ='Quad port GiGE SFP PHY',`entPhysicalModelName` ='002-0613-58',`entPhysicalSerialNum` ='091128054782',`entPhysicalContainedIn` ='5',`entPhysicalMfgName` ='Benchmark Electronics',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.2.12',`entPhysicalHardwareRev` ='4.11',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='6'[0m]
  408. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '7'[0m]
  409. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='7',`entPhysicalDescr` ='Management Port 0 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='7'[0m]
  410. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '8'[0m]
  411. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='8',`entPhysicalDescr` ='Management Port 1 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='8'[0m]
  412. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '9'[0m]
  413. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='9',`entPhysicalDescr` ='Management Port 2 10/100 Ethernet Copper',`entPhysicalClass` ='port',`entPhysicalName` ='Mgmt2',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.3',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='9'[0m]
  414. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '10'[0m]
  415. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='10',`entPhysicalDescr` ='Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='M0',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='1',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='10'[0m]
  416. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '11'[0m]
  417. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='11',`entPhysicalDescr` ='Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='M1',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='2',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='11'[0m]
  418. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '12'[0m]
  419. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='12',`entPhysicalDescr` ='Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='3',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='12'[0m]
  420. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '13'[0m]
  421. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='13',`entPhysicalDescr` ='Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1',`entPhysicalClass` ='port',`entPhysicalName` ='',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='6',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='4',`entPhysicalVendorType` ='enterprises.9148.6.1.1.9.2',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='13'[0m]
  422. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '18'[0m]
  423. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='18',`entPhysicalDescr` ='Intel Pentium Core 2 Duo Module',`entPhysicalClass` ='module',`entPhysicalName` ='Host CPU Processor',`entPhysicalModelName` ='',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='5',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.4.7',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='18'[0m]
  424. .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '39' AND entPhysicalIndex = '19'[0m]
  425. SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='19',`entPhysicalDescr` ='TLS Hardware Accelerator',`entPhysicalClass` ='module',`entPhysicalName` ='BCM5823',`entPhysicalModelName` ='BCM5823',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='BROADCOM',`entPhysicalParentRelPos` ='7',`entPhysicalVendorType` ='enterprises.9148.6.1.1.8.8.6',`entPhysicalHardwareRev` ='1',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='39' AND entPhysicalIndex='19'[0m]
  426. .
  427. SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '39'[0m]
  428.  
  429. >> Runtime for discovery module 'entity-physical': 0.3180 seconds with 9744 bytes
  430. >> SNMP: [1/0.29s] MySQL: [31/0.01s] RRD: [0/0.00s]
  431. #### Unload disco module entity-physical ####
  432.  
  433. Modules status: Global- OS- Device  Module [ entity-state ] disabled on os.
  434.  
  435. Modules status: Global+ OS+ Device  
  436. #### Load disco module processors ####
  437. No YAML Discovery data.
  438. Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad[0m]
  439. hrProcessorLoad = No Such Object available on this agent at this OID
  440.  
  441. UCD Resources: SQL[[0;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = '39'[0m]
  442. SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '39'[0m]
  443. SQL[[0;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '39'[0m]
  444. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m]
  445. No Such Object available on this agent at this OID
  446.  
  447. SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`='39'[0m]
  448. SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`)  VALUES ('39','39','758','processors',NOW(),'3','Processor Removed: acmeCPU 0 Processor','')[0m]
  449. -SQL[[0;33mDELETE FROM `processors` WHERE `device_id`='39'[0m]
  450. SQL[[0;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL[0m]
  451.  
  452.  
  453. >> Runtime for discovery module 'processors': 0.3190 seconds with 68768 bytes
  454. >> SNMP: [2/0.32s] MySQL: [7/0.00s] RRD: [0/0.00s]
  455. #### Unload disco module processors ####
  456.  
  457. Modules status: Global+ OS+ Device  
  458. #### Load disco module mempools ####
  459. SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '39' AND `mempool_type` = 'cemp'[0m]
  460. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
  461. hpLocalMem = No Such Object available on this agent at this OID
  462.  
  463. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
  464. hpGlobalMem = No Such Object available on this agent at this OID
  465.  
  466. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m]
  467. hrStorageEntry = No Such Object available on this agent at this OID
  468.  
  469. SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id`  = '39'[0m]
  470. 0 -> acme-mem
  471. -SQL[[0;33mDELETE FROM `mempools` WHERE `mempool_id` = '108'[0m]
  472.  
  473.  
  474. >> Runtime for discovery module 'mempools': 0.1120 seconds with 41528 bytes
  475. >> SNMP: [3/0.11s] MySQL: [3/0.00s] RRD: [0/0.00s]
  476. #### Unload disco module mempools ####
  477.  
  478. Modules status: Global+ OS+ Device  
  479. #### Load disco module cisco-vrf-lite ####
  480. SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '39' [0m]
  481.  
  482. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2608 bytes
  483. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  484. #### Unload disco module cisco-vrf-lite ####
  485.  
  486. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  487.  
  488. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  489.  
  490. Modules status: Global- OS- Device  Module [ vrf ] disabled on os.
  491.  
  492. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  493.  
  494. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  495.  
  496. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  497.  
  498. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  499.  
  500. Modules status: Global+ OS+ Device  
  501. #### Load disco module ipv4-addresses ####
  502. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex[0m]
  503. ipAdEntIfIndex.* 5
  504. ipAdEntIfIndex.* 7
  505. ipAdEntIfIndex.* 7
  506. ipAdEntIfIndex.* 7
  507. ipAdEntIfIndex.* 7
  508. ipAdEntIfIndex.* 7
  509. ipAdEntIfIndex.* 7
  510. ipAdEntIfIndex.* 7
  511. ipAdEntIfIndex.* 7
  512. ipAdEntIfIndex.* 7
  513. ipAdEntIfIndex.* 7
  514. ipAdEntIfIndex.* 7
  515. ipAdEntIfIndex.* 7
  516. ipAdEntIfIndex.* 7
  517. ipAdEntIfIndex.* 7
  518. ipAdEntIfIndex.* 7
  519. ipAdEntIfIndex.* 7
  520. ipAdEntIfIndex.* 7
  521. ipAdEntIfIndex.* 7
  522. ipAdEntIfIndex.* 7
  523. ipAdEntIfIndex.* 7
  524. ipAdEntIfIndex.* 7
  525. ipAdEntIfIndex.* 7
  526. ipAdEntIfIndex.* 7
  527. ipAdEntIfIndex.* 7
  528. ipAdEntIfIndex.* 7
  529. ipAdEntIfIndex.* 7
  530. ipAdEntIfIndex.* 7
  531. ipAdEntIfIndex.* 7
  532. ipAdEntIfIndex.* 7
  533. ipAdEntIfIndex.* 7
  534. ipAdEntIfIndex.* 7
  535. ipAdEntIfIndex.* 7
  536. ipAdEntIfIndex.* 7
  537. ipAdEntIfIndex.* 7
  538. ipAdEntIfIndex.* 7
  539. ipAdEntIfIndex.* 7
  540. ipAdEntIfIndex.* 7
  541. ipAdEntIfIndex.* 7
  542. ipAdEntIfIndex.* 7
  543. ipAdEntIfIndex.* 7
  544. ipAdEntIfIndex.* 7
  545. ipAdEntIfIndex.* 7
  546. ipAdEntIfIndex.* 7
  547. ipAdEntIfIndex.* 7
  548. ipAdEntIfIndex.* 7
  549. ipAdEntIfIndex.* 7
  550. ipAdEntIfIndex.* 7
  551. ipAdEntIfIndex.* 7
  552. ipAdEntIfIndex.* 7
  553. ipAdEntIfIndex.* 7
  554. ipAdEntIfIndex.* 7
  555. ipAdEntIfIndex.* 7
  556. ipAdEntIfIndex.* 7
  557. ipAdEntIfIndex.* 7
  558. ipAdEntIfIndex.* 7
  559. ipAdEntIfIndex.* 7
  560. ipAdEntIfIndex.* 7
  561. ipAdEntIfIndex.* 7
  562. ipAdEntIfIndex.* 7
  563. ipAdEntIfIndex.* 7
  564. ipAdEntIfIndex.* 7
  565. ipAdEntIfIndex.* 7
  566. ipAdEntIfIndex.* 7
  567. ipAdEntIfIndex.* 7
  568. ipAdEntIfIndex.* 7
  569. ipAdEntIfIndex.* 7
  570. ipAdEntIfIndex.* 7
  571. ipAdEntIfIndex.* 7
  572. ipAdEntIfIndex.* 7
  573. ipAdEntIfIndex.* 7
  574. ipAdEntIfIndex.* 7
  575. ipAdEntIfIndex.* 7
  576. ipAdEntIfIndex.* 7
  577. ipAdEntIfIndex.* 7
  578. ipAdEntIfIndex.* 7
  579. ipAdEntIfIndex.* 7
  580. ipAdEntIfIndex.* 7
  581. ipAdEntIfIndex.* 7
  582. ipAdEntIfIndex.* 7
  583. ipAdEntIfIndex.* 7
  584. ipAdEntIfIndex.* 7
  585. ipAdEntIfIndex.* 7
  586. ipAdEntIfIndex.* 7
  587. ipAdEntIfIndex.* 7
  588. ipAdEntIfIndex.* 7
  589. ipAdEntIfIndex.* 7
  590. ipAdEntIfIndex.* 7
  591. ipAdEntIfIndex.* 7
  592. ipAdEntIfIndex.* 7
  593. ipAdEntIfIndex.* 7
  594. ipAdEntIfIndex.* 7
  595. ipAdEntIfIndex.* 7
  596. ipAdEntIfIndex.* 7
  597. ipAdEntIfIndex.* 7
  598. ipAdEntIfIndex.* 7
  599. ipAdEntIfIndex.* 7
  600. ipAdEntIfIndex.* 7
  601. ipAdEntIfIndex.* 7
  602. ipAdEntIfIndex.* 7
  603. ipAdEntIfIndex.* 7
  604. ipAdEntIfIndex.* 5
  605. ipAdEntIfIndex.* 5
  606. ipAdEntIfIndex.* 5
  607. ipAdEntIfIndex.* 7
  608. ipAdEntIfIndex.* 7
  609. ipAdEntIfIndex.* 7
  610. ipAdEntIfIndex.* 7
  611. ipAdEntIfIndex.* 7
  612. ipAdEntIfIndex.* 7
  613. ipAdEntIfIndex.* 7
  614. ipAdEntIfIndex.* 7
  615. ipAdEntIfIndex.* 7
  616. ipAdEntIfIndex.* 7
  617. ipAdEntIfIndex.* 7
  618. ipAdEntIfIndex.* 7
  619. ipAdEntIfIndex.* 7
  620. ipAdEntIfIndex.* 7
  621. ipAdEntIfIndex.* 7
  622. ipAdEntIfIndex.* 7
  623. ipAdEntIfIndex.* 7
  624. ipAdEntIfIndex.* 7
  625. ipAdEntIfIndex.* 2
  626. ipAdEntIfIndex.* 1
  627. ipAdEntIfIndex.* 5
  628. ipAdEntIfIndex.* 5
  629. ipAdEntIfIndex.* 5
  630.  
  631. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
  632. *
  633.  
  634. SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '39' AND `ifIndex` = '5'[0m]
  635. SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '39' AND `ifIndex` = '5'[0m]
  636. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  637. SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  638. sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = 'x.x.x.x/24'[0m]
  639. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542' [0m]
  640. SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = 'x.x.x.x' AND `ipv4_prefixlen` = '24' AND `port_id` = '2542'[0m]
  641. .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.x.x.x.x[0m]
  642. *
  643.  
  644. >> Runtime for discovery module 'ipv4-addresses': 3.8500 seconds with 36792 bytes
  645. >> SNMP: [128/3.05s] MySQL: [890/0.79s] RRD: [0/0.00s]
  646. #### Unload disco module ipv4-addresses ####
  647.  
  648. Modules status: Global+ OS+ Device  
  649. #### Load disco module ipv6-addresses ####
  650. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
  651. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  652.  
  653. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
  654. .*.*.8.1.2 No Such Object available on this agent at this OID
  655.  
  656. SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '39' OR `ports`.`device_id` IS NULL[0m]
  657.  
  658.  
  659. >> Runtime for discovery module 'ipv6-addresses': 0.0290 seconds with 1376 bytes
  660. >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
  661. #### Unload disco module ipv6-addresses ####
  662.  
  663. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  664.  
  665. Modules status: Global+ OS+ Device  
  666. #### Load disco module sensors ####
  667.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr[0m]
  668. entPhysicalDescr.1 = Assy, NetNet4500
  669. entPhysicalDescr.2 = Assy, 300 Watt Power 110V Supply
  670. entPhysicalDescr.3 = Assy, 300 Watt Power 110V Supply
  671. entPhysicalDescr.4 = Assy, 4-fan unit
  672. entPhysicalDescr.5 = PHY Slot
  673. entPhysicalDescr.6 = Assy, 4 Port SFP with QOS and IPSec
  674. entPhysicalDescr.7 = Management Port 0 10/100 Ethernet Copper
  675. entPhysicalDescr.8 = Management Port 1 10/100 Ethernet Copper
  676. entPhysicalDescr.9 = Management Port 2 10/100 Ethernet Copper
  677. entPhysicalDescr.10 = Media  port 0 10/100/1000 Ethernet Copper - Logical Slot 0 Port 0
  678. entPhysicalDescr.11 = Media  port 1 10/100/1000 Ethernet Copper - Logical Slot 0 Port 1
  679. entPhysicalDescr.12 = Media  port 2 10/100/1000 Ethernet Copper - Logical Slot 1 Port 0
  680. entPhysicalDescr.13 = Media  port 3 10/100/1000 Ethernet Copper - Logical Slot 1 Port 1
  681. entPhysicalDescr.18 = Intel Pentium Core 2 Duo Module
  682. entPhysicalDescr.19 = TLS Hardware Accelerator
  683.  
  684.  entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName[0m]
  685. entPhysicalName.1 = Main Board
  686. entPhysicalName.2 = Power Supply A
  687. entPhysicalName.3 = Power Supply B
  688. entPhysicalName.4 = 4-Fan unit
  689. entPhysicalName.5 = PHY Slot
  690. entPhysicalName.6 = Quad port GiGE SFP PHY
  691. entPhysicalName.7 = Mgmt0
  692. entPhysicalName.8 = Mgmt1
  693. entPhysicalName.9 = Mgmt2
  694. entPhysicalName.10 = M0
  695. entPhysicalName.11 = M1
  696. entPhysicalName.12 =
  697. entPhysicalName.13 =
  698. entPhysicalName.18 = Host CPU Processor
  699. entPhysicalName.19 = BCM5823
  700.  
  701.  entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType[0m]
  702. entPhySensorType = No Such Object available on this agent at this OID
  703.  
  704.  entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale[0m]
  705. entPhySensorScale = No Such Object available on this agent at this OID
  706.  
  707.  entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision[0m]
  708. entPhySensorPrecision = No Such Object available on this agent at this OID
  709.  
  710.  entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue[0m]
  711. entPhySensorValue = No Such Object available on this agent at this OID
  712.  
  713.  
  714. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'ipmi_hostname' [0m]
  715. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  716. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  717. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  718. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'ipmi'[0m]
  719. Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  720.  
  721. Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  722.  
  723. Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  724.  
  725. Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  726.  
  727. Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  728.  
  729. Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  730.  
  731. Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  732.  
  733. Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  734.  
  735. Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  736.  
  737. Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  738.  
  739. Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  740.  
  741. State: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  742.  
  743. Temperature: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  744.  
  745. Voltage: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  746.  
  747. Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  748.  
  749. Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  750.  
  751. Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  752.  
  753. Delay: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  754.  
  755. Quality_factor: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  756.  
  757. Chromatic_dispersion: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  758.  
  759. Ber: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  760.  
  761. Eer: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  762.  
  763. Waterflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '39' AND S.poller_type = 'snmp'[0m]
  764.  
  765.  
  766. >> Runtime for discovery module 'sensors': 0.1620 seconds with 55600 bytes
  767. >> SNMP: [6/0.15s] MySQL: [28/0.01s] RRD: [0/0.00s]
  768. #### Unload disco module sensors ####
  769.  
  770. Modules status: Global+ OS+ Device  
  771. #### Load disco module storage ####
  772. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m]
  773. hrStorageEntry = No Such Object available on this agent at this OID
  774.  
  775. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable[0m]
  776. dskTable = No Such Object available on this agent at this OID
  777.  
  778. SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '39' AND `storage_type` != 'dsk'[0m]
  779. SQL[[0;33mSELECT * FROM `storage` WHERE `device_id`  = '39'[0m]
  780.  
  781.  
  782. >> Runtime for discovery module 'storage': 0.0380 seconds with 8376 bytes
  783. >> SNMP: [2/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s]
  784. #### Unload disco module storage ####
  785.  
  786. Modules status: Global+ OS+ Device  
  787. #### Load disco module hr-device ####
  788. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry[0m]
  789. hrDeviceEntry = No Such Object available on this agent at this OID
  790.  
  791. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry[0m]
  792. hrProcessorEntry = No Such Object available on this agent at this OID
  793.  
  794. Array
  795. (
  796. )
  797. SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '39'[0m]
  798.  
  799.  
  800. >> Runtime for discovery module 'hr-device': 0.0890 seconds with 3704 bytes
  801. >> SNMP: [2/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s]
  802. #### Unload disco module hr-device ####
  803.  
  804. Modules status: Global+ OS+ Device  
  805. #### Load disco module discovery-protocols ####
  806.  CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache[0m]
  807. cdpCache = No Such Object available on this agent at this OID
  808.  
  809.  
  810.  LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemTable[0m]
  811. lldpRemTable = No Such Object available on this agent at this OID
  812.  
  813.  
  814.  OSPF Discovery: SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='39'[0m]
  815.  
  816. SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '39'[0m]
  817. SQL[[0;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL[0m]
  818.  0 orphaned links deleted
  819.  
  820. >> Runtime for discovery module 'discovery-protocols': 0.0420 seconds with 4848 bytes
  821. >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
  822. #### Unload disco module discovery-protocols ####
  823.  
  824. Modules status: Global+ OS+ Device  
  825. #### Load disco module arp-table ####
  826. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
  827. ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  828.  
  829. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
  830. ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
  831.  
  832. SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='39' AND `context_name`=''[0m]
  833. SQL[[0;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL[0m]
  834.  
  835.  
  836. >> Runtime for discovery module 'arp-table': 0.0680 seconds with 2360 bytes
  837. >> SNMP: [0/0.00s] MySQL: [2/0.02s] RRD: [0/0.00s]
  838. #### Unload disco module arp-table ####
  839.  
  840. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  841.  
  842. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  843.  
  844. Modules status: Global+ OS+ Device  
  845. #### Load disco module bgp-peers ####
  846. SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 bgpLocalAs[0m]
  847. "M0"
  848.  
  849. No BGP on hostPeers :
  850. SQL[[0;33mDELETE FROM `bgpPeers` WHERE device_id='39' AND context_name=''[0m]
  851. SQL[[0;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id='39' AND context_name=''[0m]
  852.  
  853. SQL[[0;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id='39'[0m]
  854.  
  855. >> Runtime for discovery module 'bgp-peers': 0.0130 seconds with 5456 bytes
  856. >> SNMP: [1/0.01s] MySQL: [3/0.00s] RRD: [0/0.00s]
  857. #### Unload disco module bgp-peers ####
  858.  
  859. Modules status: Global+ OS+ Device  
  860. #### Load disco module vlans ####
  861. SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '39'[0m]
  862. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
  863. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  864.  
  865. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
  866. No Such Object available on this agent at this OID
  867.  
  868.  
  869.  
  870. >> Runtime for discovery module 'vlans': 0.0380 seconds with 9232 bytes
  871. >> SNMP: [2/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s]
  872. #### Unload disco module vlans ####
  873.  
  874. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  875.  
  876. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  877.  
  878. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  879.  
  880. Modules status: Global+ OS+ Device  
  881. #### Load disco module ucd-diskio ####
  882. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry[0m]
  883. diskIOEntry = No Such Object available on this agent at this OID
  884.  
  885. Array
  886. (
  887. )
  888. SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id`  = '39'[0m]
  889.  
  890.  
  891. >> Runtime for discovery module 'ucd-diskio': 0.0150 seconds with 3120 bytes
  892. >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
  893. #### Unload disco module ucd-diskio ####
  894.  
  895. Modules status: Global- OS- Device  Module [ applications ] disabled on os.
  896.  
  897. Modules status: Global+ OS+ Device  
  898. #### Load disco module services ####
  899.  
  900. >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes
  901. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  902. #### Unload disco module services ####
  903.  
  904. Modules status: Global+ OS+ Device  
  905. #### Load disco module stp ####
  906. SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '39'[0m]
  907. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
  908. No Such Object available on this agent at this OID
  909.  
  910.  
  911.  
  912. >> Runtime for discovery module 'stp': 0.0160 seconds with 5904 bytes
  913. >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
  914. #### Unload disco module stp ####
  915.  
  916. Modules status: Global+ OS+ Device  
  917. #### Load disco module ntp ####
  918.  
  919. >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
  920. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  921. #### Unload disco module ntp ####
  922.  
  923. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  924.  
  925. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  926.  
  927. Modules status: Global+ OS+ Device  
  928. #### Load disco module wireless ####
  929. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='ap-count'[0m]
  930. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='clients'[0m]
  931. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='quality'[0m]
  932. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='capacity'[0m]
  933. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='utilization'[0m]
  934. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='rate'[0m]
  935. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='ccq'[0m]
  936. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='snr'[0m]
  937. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='ssr'[0m]
  938. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='mse'[0m]
  939. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='rssi'[0m]
  940. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='power'[0m]
  941. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='noise-floor'[0m]
  942. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='errors'[0m]
  943. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='error-ratio'[0m]
  944. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='error-rate'[0m]
  945. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='frequency'[0m]
  946. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='39' AND `sensor_class`='distance'[0m]
  947.  
  948. >> Runtime for discovery module 'wireless': 0.0060 seconds with 185832 bytes
  949. >> SNMP: [0/0.00s] MySQL: [18/0.00s] RRD: [0/0.00s]
  950. #### Unload disco module wireless ####
  951.  
  952. Modules status: Global+ OS+ Device  
  953. #### Load disco module fdb-table ####
  954. SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '39'[0m]
  955. SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '39'[0m]
  956. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qTpFdbPort[0m]
  957. dot1qTpFdbPort = No Such Object available on this agent at this OID
  958.  
  959. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dTpFdbPort[0m]
  960. dot1dTpFdbPort = No Such Object available on this agent at this OID
  961.  
  962.  
  963.  
  964. >> Runtime for discovery module 'fdb-table': 0.0370 seconds with 3000 bytes
  965. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  966. #### Unload disco module fdb-table ####
  967.  
  968. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '39' AND `attrib_type` = 'poll_mib' [0m]
  969. SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='7.514' WHERE `device_id` = '39'[0m]
  970. Discovered in 7.514 seconds
  971.  
  972. SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','39','1525900231.5229','7.666','1','librenms')[0m]
  973. ./discovery.php 39 2018-05-09 21:10:39 - 1 devices discovered in 7.666 secs
  974. SNMP [160/5.46s]: Get[135/4.58s] Getnext[1/0.01s] Walk[24/0.86s]
  975. MySQL [1011/0.85s]: Cell[654/0.45s] Row[5/0.00s] Rows[66/0.03s] Column[2/0.00s] Update[272/0.35s] Insert[5/0.00s] Delete[7/0.02s]
  976. RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]
  977.