- From the switch itself
- ------
- IPLVINE-CISCO9396-01# show int eth 1/3 trans det
- Ethernet1/3
- transceiver is present
- type is 1000base-LH
- name is Fiberstore
- part number is SFP1G-LH-31
- revision is A0
- serial number is F16ACO17646
- nominal bitrate is 1300 MBit/sec
- Link length supported for 9/125um fiber is 10 km
- cisco id is 3
- cisco extended id number is 4
- SFP Detail Diagnostics Information (internal calibration)
- ----------------------------------------------------------------------------
- Current Alarms Warnings
- Measurement High Low High Low
- ----------------------------------------------------------------------------
- Temperature 40.72 C 100.00 C -50.00 C 85.00 C -40.00 C
- Voltage 3.35 V 3.79 V 2.80 V 3.46 V 3.13 V
- Current 15.85 mA 90.00 mA 0.00 mA 85.00 mA 0.00 mA
- Tx Power -6.05 dBm -1.50 dBm -10.50 dBm -3.00 dBm -9.03 dBm
- Rx Power -6.17 dBm -3.00 dBm -26.98 dBm -5.00 dBm -23.97 dBm
- Transmit Fault Count = 0
- ----------------------------------------------------------------------------
- Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
- From snmpwalk of the switch:
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 = INTEGER: 3
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 = INTEGER: 15
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 = INTEGER: 40
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 = INTEGER: -6
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534 = INTEGER: -6
- From a Poller capture
- -----
- entPhysicalDescr.300003522 = Ethernet1/3 Lane 1 Transceiver Voltage Sensor
- entPhysicalDescr.300003524 = Ethernet1/3 Lane 1 Transceiver Bias Current Sensor
- entPhysicalDescr.300003527 = Ethernet1/3 Lane 1 Transceiver Temperature Sensor
- entPhysicalDescr.300003533 = Ethernet1/3 Lane 1 Transceiver Receive Power Sensor
- entPhysicalDescr.300003534 = Ethernet1/3 Lane 1 Transceiver Transmit Power Sensor
- root@indy-librenms:/home/mhammett# snmpget -c 'mwix2016' -v2c 733-Nexus .1.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 = INTEGER: 3
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 = INTEGER: 15
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 = INTEGER: 40
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 = INTEGER: -6
- iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534 = INTEGER: -6
- [RRD Disabled]0.003
- RRD[last 733-nexus/sensor-voltage-cisco-entity-sensor-300003522.rrd --daemon unix:/var/run/rrdcached.sock]
- RRD[update 733-nexus/sensor-voltage-cisco-entity-sensor-300003522.rrd N:0.003 --daemon unix:/var/run/rrdcached.sock]
- [RRD Disabled]0.015
- RRD[last 733-nexus/sensor-current-cisco-entity-sensor-300003524.rrd --daemon unix:/var/run/rrdcached.sock]
- RRD[update 733-nexus/sensor-current-cisco-entity-sensor-300003524.rrd N:0.015 --daemon unix:/var/run/rrdcached.sock]
- [RRD Disabled]0.04
- RRD[last 733-nexus/sensor-temperature-cisco-entity-sensor-300003527.rrd --daemon unix:/var/run/rrdcached.sock]
- RRD[update 733-nexus/sensor-temperature-cisco-entity-sensor-300003527.rrd N:0.04 --daemon unix:/var/run/rrdcached.sock]
- [RRD Disabled]-0.006
- RRD[last 733-nexus/sensor-dbm-cisco-entity-sensor-300003533.rrd --daemon unix:/var/run/rrdcached.sock]
- RRD[update 733-nexus/sensor-dbm-cisco-entity-sensor-300003533.rrd N:-0.006 --daemon unix:/var/run/rrdcached.sock]
- [RRD Disabled]-0.006
- RRD[last 733-nexus/sensor-dbm-cisco-entity-sensor-300003534.rrd --daemon unix:/var/run/rrdcached.sock]
- RRD[update 733-nexus/sensor-dbm-cisco-entity-sensor-300003534.rrd N:-0.006 --daemon unix:/var/run/rrdcached.sock]