From Mike Hammett, 5 Years ago, written in Plain Text.
Embed
  1. From the switch itself
  2. ------
  3. IPLVINE-CISCO9396-01# show int eth 1/3 trans det
  4. Ethernet1/3
  5.     transceiver is present
  6.     type is 1000base-LH
  7.     name is Fiberstore
  8.     part number is SFP1G-LH-31
  9.     revision is A0
  10.     serial number is F16ACO17646
  11.     nominal bitrate is 1300 MBit/sec
  12.     Link length supported for 9/125um fiber is 10 km
  13.     cisco id is 3
  14.     cisco extended id number is 4
  15.  
  16.            SFP Detail Diagnostics Information (internal calibration)
  17.   ----------------------------------------------------------------------------
  18.                 Current              Alarms                  Warnings
  19.                 Measurement     High        Low         High          Low
  20.   ----------------------------------------------------------------------------
  21.   Temperature   40.72 C       100.00 C    -50.00 C     85.00 C      -40.00 C
  22.   Voltage        3.35 V         3.79 V      2.80 V      3.46 V        3.13 V
  23.   Current       15.85 mA       90.00 mA     0.00 mA    85.00 mA       0.00 mA
  24.   Tx Power      -6.05 dBm      -1.50 dBm  -10.50 dBm   -3.00 dBm     -9.03 dBm
  25.   Rx Power      -6.17 dBm      -3.00 dBm  -26.98 dBm   -5.00 dBm    -23.97 dBm
  26.   Transmit Fault Count = 0
  27.   ----------------------------------------------------------------------------
  28.   Note: ++  high-alarm; +  high-warning; --  low-alarm; -  low-warning
  29.  
  30. From snmpwalk of the switch:
  31.  
  32. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 = INTEGER: 3
  33. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 = INTEGER: 15
  34. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 = INTEGER: 40
  35. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 = INTEGER: -6
  36. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534 = INTEGER: -6
  37.  
  38.  
  39.  
  40. From a Poller capture
  41. -----
  42. entPhysicalDescr.300003522 = Ethernet1/3 Lane 1 Transceiver Voltage Sensor
  43. entPhysicalDescr.300003524 = Ethernet1/3 Lane 1 Transceiver Bias Current Sensor
  44. entPhysicalDescr.300003527 = Ethernet1/3 Lane 1 Transceiver Temperature Sensor
  45. entPhysicalDescr.300003533 = Ethernet1/3 Lane 1 Transceiver Receive Power Sensor
  46. entPhysicalDescr.300003534 = Ethernet1/3 Lane 1 Transceiver Transmit Power Sensor
  47.  
  48. root@indy-librenms:/home/mhammett# snmpget -c 'mwix2016' -v2c 733-Nexus .1.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534
  49. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003522 = INTEGER: 3
  50. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003524 = INTEGER: 15
  51. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003527 = INTEGER: 40
  52. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003533 = INTEGER: -6
  53. iso.3.6.1.4.1.9.9.91.1.1.1.1.4.300003534 = INTEGER: -6
  54.  
  55. [RRD Disabled]0.003
  56. RRD[last 733-nexus/sensor-voltage-cisco-entity-sensor-300003522.rrd  --daemon unix:/var/run/rrdcached.sock]
  57. RRD[update 733-nexus/sensor-voltage-cisco-entity-sensor-300003522.rrd N:0.003 --daemon unix:/var/run/rrdcached.sock]
  58. [RRD Disabled]0.015
  59. RRD[last 733-nexus/sensor-current-cisco-entity-sensor-300003524.rrd  --daemon unix:/var/run/rrdcached.sock]
  60. RRD[update 733-nexus/sensor-current-cisco-entity-sensor-300003524.rrd N:0.015 --daemon unix:/var/run/rrdcached.sock]
  61. [RRD Disabled]0.04
  62. RRD[last 733-nexus/sensor-temperature-cisco-entity-sensor-300003527.rrd  --daemon unix:/var/run/rrdcached.sock]
  63. RRD[update 733-nexus/sensor-temperature-cisco-entity-sensor-300003527.rrd N:0.04 --daemon unix:/var/run/rrdcached.sock]
  64. [RRD Disabled]-0.006
  65. RRD[last 733-nexus/sensor-dbm-cisco-entity-sensor-300003533.rrd  --daemon unix:/var/run/rrdcached.sock]
  66. RRD[update 733-nexus/sensor-dbm-cisco-entity-sensor-300003533.rrd N:-0.006 --daemon unix:/var/run/rrdcached.sock]
  67. [RRD Disabled]-0.006
  68. RRD[last 733-nexus/sensor-dbm-cisco-entity-sensor-300003534.rrd  --daemon unix:/var/run/rrdcached.sock]
  69. RRD[update 733-nexus/sensor-dbm-cisco-entity-sensor-300003534.rrd N:-0.006 --daemon unix:/var/run/rrdcached.sock]