- -- MODULE-IDENTITY
- -- OrgName
- -- Fortinet, Inc.
- -- ContactInfo
- -- Technical Support
- -- e-mail: support@fortinet.com
- -- http://www.fortinet.com
- --
- FORTINET-FORTIMAIL-MIB DEFINITIONS ::= BEGIN
- IMPORTS
- MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
- FROM SNMPv2-CONF
- DisplayString, TEXTUAL-CONVENTION
- FROM SNMPv2-TC
- MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32, Gauge32,
- IpAddress
- FROM SNMPv2-SMI
- ifIndex
- FROM IF-MIB
- FnBoolState, FnIndex, FnSessionProto, fortinet
- FROM FORTINET-CORE-MIB;
- fnFortiMailMib MODULE-IDENTITY
- LAST-UPDATED "201306280000Z"
- ORGANIZATION
- "Fortinet Technologies, Inc."
- CONTACT-INFO
- "Technical Support
- email: support@fortinet.com
- http://www.fortinet.com
- "
- DESCRIPTION
- "Add fmlMailQueueStatistics listing mail queues and
- number of emails and size of emails in queues"
- REVISION "201306280000Z"
- DESCRIPTION
- "MIB module for Fortinet FortiMail devices"
- REVISION "201003230000Z"
- DESCRIPTION
- "Inherit FORTINET-CORE-MIB, combine FortiMail traps"
- REVISION "200910220000Z"
- DESCRIPTION
- "MIB module for FortiMail devices."
- ::= { fortinet 105 }
- --
- -- Textual conventions --
- --
- FmlIpv6Address ::= TEXTUAL-CONVENTION
- DISPLAY-HINT "2x:"
- STATUS current
- DESCRIPTION
- "This data type is used to model IPv6 addresses.
- This is a binary string of 16 octets in network
- byte-order."
- SYNTAX OCTET STRING (SIZE (16))
- FmlOpMode ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "fortimail operation mode."
- SYNTAX INTEGER {
- gateway (1),
- transparent (2),
- server (3)
- }
- FmlSysEventCodeVal ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "enumerated type for System component events."
- SYNTAX INTEGER {
- systemHalt (1),
- systemReboot (2),
- systemReload (3),
- systemUpgrade (4),
- guiUpgrade (5),
- logdiskFormat (6),
- maildiskFormat (7),
- avDBUpdate (8)
- }
- FmlRAIDCodeVal ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "enumerated type for RAID system events."
- SYNTAX INTEGER {
- degradedArray (1),
- sparesMissing (2),
- rebuildStarted (3),
- rebuildFinished (4),
- fail (5),
- failSpare (6),
- spareActive (7)
- }
- FmlHAEventIdVal ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "enumerated type for HA events."
- SYNTAX INTEGER {
- masterUnitSwitch (1),
- slaveUnitSwitch (2),
- unitShutdown (3)
- }
- FmlHAModeVal ::= TEXTUAL-CONVENTION
- STATUS current
- DESCRIPTION
- "enumerated type for HA mode."
- SYNTAX INTEGER {
- off (0),
- master (1),
- slave (2),
- configMaster (3),
- configSlave (4)
- }
- --
- --
- --
- fmlTraps OBJECT IDENTIFIER ::= { fnFortiMailMib 0 }
- fmlSystem OBJECT IDENTIFIER ::= { fnFortiMailMib 1 }
- fmlSysOptions OBJECT IDENTIFIER ::= { fmlSystem 101 }
- fmlIp OBJECT IDENTIFIER ::= { fmlSystem 102 }
- fmlMailOptions OBJECT IDENTIFIER ::= { fmlSystem 103 }
- fmlHwSensors OBJECT IDENTIFIER ::= { fmlSystem 110 }
- fmlSysHA OBJECT IDENTIFIER ::= { fmlSystem 200 }
- fmlMIBConformance OBJECT IDENTIFIER ::= { fnFortiMailMib 600 }
- --
- -- fnFortiMailMib.fmlSystem
- --
- fmlSysModel OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 64 ) )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "System model string"
- ::= { fmlSystem 1 }
- fmlSysSerial OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Device serial number"
- ::= { fmlSystem 2 }
- fmlSysVersion OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 128 ) )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Device firmware version"
- ::= { fmlSystem 3 }
- fmlSysVersionAv OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 128 ) )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Antivirus DB version"
- ::= { fmlSystem 4 }
- fmlSysOpMode OBJECT-TYPE
- SYNTAX FmlOpMode
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Operational mode (Gateway, Transparent or Server)"
- ::= { fmlSystem 5 }
- fmlSysCpuUsage OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous CPU usage"
- ::= { fmlSystem 6 }
- fmlSysMemUsage OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous memory utilization"
- ::= { fmlSystem 7 }
- fmlSysLogDiskUsage OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous log disk usage"
- ::= { fmlSystem 8 }
- fmlSysMailDiskUsage OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous mail disk usage"
- ::= { fmlSystem 9 }
- fmlSysSesCount OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous session count"
- ::= { fmlSystem 10 }
- fmlSysEventCode OBJECT-TYPE
- SYNTAX FmlSysEventCodeVal
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "System component events"
- ::= { fmlSystem 11 }
- fmlRAIDCode OBJECT-TYPE
- SYNTAX FmlRAIDCodeVal
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "RAID system events"
- ::= { fmlSystem 12 }
- fmlRAIDDevName OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "RAID Device name"
- ::= { fmlSystem 13 }
- fmlHAEventId OBJECT-TYPE
- SYNTAX FmlHAEventIdVal
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "HA event type ID"
- ::= { fmlSystem 14 }
- fmlHAUnitIp OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "Unit IP address where event occurs "
- ::= { fmlSystem 15 }
- fmlHAEventReason OBJECT-TYPE
- SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
- MAX-ACCESS accessible-for-notify
- STATUS current
- DESCRIPTION "The reason for the HA event"
- ::= { fmlSystem 16 }
- fmlSysLoad OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Instantaneous system load"
- ::= { fmlSystem 30 }
- fmlRemoteStorageStatus OBJECT-TYPE
- SYNTAX INTEGER { false(0), true(1) }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Remote Storage Status"
- ::= { fmlSystem 31 }
- --
- -- fnFortiMailMib.fmlSystem.fmlSysOptions
- --
- fmlSysOptIdleTimeout OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Idle period after which the administrator
- is automatically logged out off the system"
- ::= { fmlSysOptions 1 }
- fmlSysOptAuthTimeout OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Authentication idle timeout value"
- ::= { fmlSysOptions 2 }
- fmlSysOptsLcdProt OBJECT-TYPE
- SYNTAX FnBoolState
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Enable or disable LCD control buttons protection"
- ::= { fmlSysOptions 4 }
- --
- -- fnFortiMailMib.fmlSystem.fmlIp
- --
- fmlIpSessTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FmlIpSessEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "IP Sessions Info"
- ::= { fmlIp 2 }
- fmlIpSessEntry OBJECT-TYPE
- SYNTAX FmlIpSessEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Particular IP Session info"
- INDEX { fmlIpSessIndex }
- ::= { fmlIpSessTable 1 }
- FmlIpSessEntry ::=
- SEQUENCE {
- fmlIpSessIndex FnIndex,
- fmlIpSessProto FnSessionProto,
- fmlIpSessFromAddr IpAddress,
- fmlIpv6SessFromAddr FmlIpv6Address,
- fmlIpSessFromPort Integer32,
- fmlIpSessToAddr IpAddress,
- fmlIpv6SessToAddr FmlIpv6Address,
- fmlIpSessToPort Integer32,
- fmlIpSessExp Gauge32
- }
- fmlIpSessIndex OBJECT-TYPE
- SYNTAX FnIndex
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "An index value that uniquely identifies
- an IP session"
- ::= { fmlIpSessEntry 1 }
- fmlIpSessProto OBJECT-TYPE
- SYNTAX FnSessionProto
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "The protocol of the connection"
- ::= { fmlIpSessEntry 2 }
- fmlIpSessFromAddr OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Source IP address"
- ::= { fmlIpSessEntry 3 }
- fmlIpv6SessFromAddr OBJECT-TYPE
- SYNTAX FmlIpv6Address
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Source IP address"
- ::= { fmlIpSessEntry 4}
- fmlIpSessFromPort OBJECT-TYPE
- SYNTAX Integer32 ( 0 .. 65535 )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Source Port number"
- ::= { fmlIpSessEntry 5 }
- fmlIpSessToAddr OBJECT-TYPE
- SYNTAX IpAddress
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Destination IP address"
- ::= { fmlIpSessEntry 6 }
- fmlIpv6SessToAddr OBJECT-TYPE
- SYNTAX FmlIpv6Address
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Source IP address"
- ::= { fmlIpSessEntry 7}
- fmlIpSessToPort OBJECT-TYPE
- SYNTAX Integer32 ( 0 .. 65535 )
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Destination Port number"
- ::= { fmlIpSessEntry 8 }
- fmlIpSessExp OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Time (in seconds) before connection expires"
- ::= { fmlIpSessEntry 9 }
- --
- -- fnFortiMailMib.fmlSystem.fmlMailOptions
- --
- fmlMailOptionsDeferQueue OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS obsolete
- DESCRIPTION "Instantaneous deferred emails number"
- ::= { fmlMailOptions 1 }
- fmlMailQueueStatistics OBJECT-TYPE
- SYNTAX SEQUENCE OF FmlMailQueueEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Statistics of mail queues"
- ::= { fmlMailOptions 2 }
- fmlMailQueueEntry OBJECT-TYPE
- SYNTAX FmlMailQueueEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Statistics of a mail queue, e.g. number of mails in queue, size of mails"
- INDEX { fmlMailQueueIndex }
- ::= { fmlMailQueueStatistics 1 }
- FmlMailQueueEntry ::= SEQUENCE {
- fmlMailQueueIndex FnIndex,
- fmlMailQueueName DisplayString,
- fmlMailQueueMailCount Gauge32,
- fmlMailQueueMailSize Gauge32
- }
- fmlMailQueueIndex OBJECT-TYPE
- SYNTAX FnIndex
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "mail queue index"
- ::= { fmlMailQueueEntry 1 }
- fmlMailQueueName OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "mail queue name"
- ::= { fmlMailQueueEntry 2 }
- fmlMailQueueMailCount OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "number of emails in mail queue"
- ::= { fmlMailQueueEntry 3 }
- fmlMailQueueMailSize OBJECT-TYPE
- SYNTAX Gauge32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "size of emails in mail queue in KB"
- ::= { fmlMailQueueEntry 4 }
- --
- -- fnFortiMailMib.fmlSystem.fmlHwSensors
- --
- fmlHwSensorCount OBJECT-TYPE
- SYNTAX Integer32
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "The number of hardware sensors in the system"
- ::= { fmlHwSensors 1 }
- fmlHwSensorTable OBJECT-TYPE
- SYNTAX SEQUENCE OF FmlHwSensorEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "A list of hardware sensors in the system user accounts"
- ::= { fmlHwSensors 2 }
- fmlHwSensorEntry OBJECT-TYPE
- SYNTAX FmlHwSensorEntry
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "An entry containing information of hardware sensors"
- INDEX { fmlHwSensorEntIndex }
- ::= { fmlHwSensorTable 1 }
- FmlHwSensorEntry ::= SEQUENCE {
- fmlHwSensorEntIndex FnIndex,
- fmlHwSensorEntName DisplayString,
- fmlHwSensorEntValue DisplayString,
- fmlHwSensorEntAlarmStatus INTEGER
- }
- fmlHwSensorEntIndex OBJECT-TYPE
- SYNTAX FnIndex
- MAX-ACCESS not-accessible
- STATUS current
- DESCRIPTION "Index of the hardware sensors"
- ::= { fmlHwSensorEntry 1 }
- fmlHwSensorEntName OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Sensor Name"
- ::= { fmlHwSensorEntry 2 }
- fmlHwSensorEntValue OBJECT-TYPE
- SYNTAX DisplayString
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Reading value of the sensor"
- ::= { fmlHwSensorEntry 3 }
- fmlHwSensorEntAlarmStatus OBJECT-TYPE
- SYNTAX INTEGER { false(0), true(1) }
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Alarm status of the sensor"
- ::= { fmlHwSensorEntry 4 }
- --
- -- fnFortiMailMib.fmlSystem.fmlSysHA
- --
- fmlHAMode OBJECT-TYPE
- SYNTAX FmlHAModeVal
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Configured HA mode"
- ::= { fmlSysHA 1 }
- fmlHAEffectiveMode OBJECT-TYPE
- SYNTAX FmlHAModeVal
- MAX-ACCESS read-only
- STATUS current
- DESCRIPTION "Effective HA mode"
- ::= { fmlSysHA 2 }
- --
- -- fnFortiMailMib.fmlTraps
- --
- fmlTrapCpuHighThreshold NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS obsolete
- DESCRIPTION "Trap being sent if CPU usage becomes too high, which is defined in FORTINET-CORE-MIB"
- ::= { fmlTraps 101 }
- fmlTrapMemLowThreshold NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS obsolete
- DESCRIPTION "Trap being sent if memory usage becomes too high, which is defined in FORTINET-CORE-MIB"
- ::= { fmlTraps 102 }
- fmlTrapLogDiskHighThreshold NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS obsolete
- DESCRIPTION "Trap being sent if Log disk usage becomes too high, which is defined in FORTINET-CORE-MIB"
- ::= { fmlTraps 103 }
- fmlTrapMailDiskHighThreshold NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial}
- STATUS current
- DESCRIPTION "Trap being sent if Mailbox disk usage becomes too high"
- ::= { fmlTraps 104 }
- fmlTrapMailDeferredQueueHighThreshold NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS current
- DESCRIPTION "Trap being sent if Mail server deferred emails becomes too high"
- ::= { fmlTraps 105 }
- fmlTrapAvThresholdEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS current
- DESCRIPTION "Trap being sent when detected virus number reaches the threshold"
- ::= { fmlTraps 106 }
- fmlTrapSpamThresholdEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial }
- STATUS current
- DESCRIPTION "Trap being sent when detected spam email number reaches the threshold"
- ::= { fmlTraps 107 }
- fmlTrapPSUFailureEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, fmlHwSensorEntName, fmlHwSensorEntValue, fmlHwSensorEntAlarmStatus }
- STATUS obsolete
- DESCRIPTION "Trap being sent when detected a power suply unit failure, which is defined in FORTINET-CORE-MIB"
- ::= { fmlTraps 108 }
- fmlTrapSystemEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, fmlSysEventCode }
- STATUS current
- DESCRIPTION "Trap being sent when system component halt, reboot, upgrade etc.,"
- ::= { fmlTraps 201 }
- fmlTrapRAIDEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, fmlRAIDCode, fmlRAIDDevName }
- STATUS current
- DESCRIPTION "Trap being sent for RAID operation"
- ::= { fmlTraps 202 }
- fmlTrapHAEvent NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, fmlHAEventId, fmlHAUnitIp, fmlHAEventReason }
- STATUS current
- DESCRIPTION "Trap being sent when HA event occurs"
- ::= { fmlTraps 203 }
- fmlTrapRemoteStorage NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, fmlRemoteStorageStatus }
- STATUS obsolete
- DESCRIPTION "Trap being sent when status of the remote storage changes"
- ::= { fmlTraps 205 }
- fmlTrapIpChange NOTIFICATION-TYPE
- OBJECTS { fmlSysSerial, ifIndex }
- STATUS obsolete
- DESCRIPTION "Trap being sent when IP address of
- the specified interface has been
- changed, which is defined in FORTINET-CORE-MIB"
- ::= { fmlTraps 301 }
- --
- -- fnFortiMailMib.fmlMIBConformance
- --
- fmlSystemConformanceGroup OBJECT-GROUP
- OBJECTS { fmlSysModel, fmlSysSerial, fmlSysVersion, fmlSysVersionAv, fmlSysOpMode, fmlSysCpuUsage,
- fmlSysMemUsage, fmlSysLogDiskUsage, fmlSysMailDiskUsage, fmlSysSesCount, fmlSysEventCode,
- fmlRAIDCode, fmlRAIDDevName, fmlHAEventId, fmlHAUnitIp, fmlHAEventReason,
- fmlSysLoad }
- STATUS current
- DESCRIPTION
- "object related to fortimail system."
- ::= { fmlMIBConformance 1 }
- fmlSysOptionsConformanceGroup OBJECT-GROUP
- OBJECTS { fmlSysOptIdleTimeout, fmlSysOptAuthTimeout, fmlSysOptsLcdProt }
- STATUS current
- DESCRIPTION
- "object related to fortimail system option."
- ::= { fmlMIBConformance 2 }
- fmlIpConformanceGroup OBJECT-GROUP
- OBJECTS { fmlIpSessProto, fmlIpSessFromAddr, fmlIpSessFromPort, fmlIpSessToAddr,
- fmlIpSessToPort, fmlIpSessExp }
- STATUS current
- DESCRIPTION
- "object related to fortimail ip."
- ::= { fmlMIBConformance 3 }
- fmlMailOptionsConformanceGroup OBJECT-GROUP
- OBJECTS { fmlMailQueueName, fmlMailQueueMailCount, fmlMailQueueMailSize }
- STATUS current
- DESCRIPTION
- "object related to fortimail mail options."
- ::= { fmlMIBConformance 4 }
- fmlHwSensorsConformanceGroup OBJECT-GROUP
- OBJECTS { fmlHwSensorCount, fmlHwSensorEntName, fmlHwSensorEntValue,
- fmlHwSensorEntAlarmStatus }
- STATUS current
- DESCRIPTION
- "object related to fortimail hw sensors."
- ::= { fmlMIBConformance 5 }
- fmlHAModeConformanceGroup OBJECT-GROUP
- OBJECTS { fmlHAMode, fmlHAEffectiveMode }
- STATUS current
- DESCRIPTION
- "object related to fortimail HA mode."
- ::= { fmlMIBConformance 6 }
- fmlTrapsComplianceGroup NOTIFICATION-GROUP
- NOTIFICATIONS {
- fmlTrapMailDiskHighThreshold,
- fmlTrapMailDeferredQueueHighThreshold,
- fmlTrapAvThresholdEvent,
- fmlTrapSpamThresholdEvent,
- fmlTrapSystemEvent,
- fmlTrapRAIDEvent,
- fmlTrapHAEvent
- }
- STATUS current
- DESCRIPTION "Event notifications"
- ::= { fmlMIBConformance 7 }
- fmlObsoleteTrapsComplianceGroup NOTIFICATION-GROUP
- NOTIFICATIONS {
- fmlTrapCpuHighThreshold,
- fmlTrapMemLowThreshold,
- fmlTrapLogDiskHighThreshold,
- fmlTrapPSUFailureEvent,
- fmlTrapIpChange
- }
- STATUS obsolete
- DESCRIPTION "Event notifications, items in this group are defined in FORTINET-CORE-MIB"
- ::= { fmlMIBConformance 8 }
- fmlMIBCompliance MODULE-COMPLIANCE
- STATUS current
- DESCRIPTION
- "the compliance statement for the application MIB."
- MODULE -- this module
- GROUP fmlSystemConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlSysOptionsConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlIpConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlMailOptionsConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlHwSensorsConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlHAModeConformanceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- GROUP fmlTrapsComplianceGroup
- DESCRIPTION
- "this group is mandatory for all Fortimail appliances supporting this MIB."
- ::= { fmlMIBConformance 100 }
- fmlObsoleteMIBCompliance MODULE-COMPLIANCE
- STATUS obsolete
- DESCRIPTION
- "the obsolete compliance statement for the application MIB."
- MODULE
- GROUP fmlObsoleteTrapsComplianceGroup
- DESCRIPTION
- "items in this group are defined in FORTINET-CORE-MIB."
- ::= { fmlMIBConformance 101 }
- END