- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: 386fea0321a86b197d302629a04d20d480828d6d
- Commit Date: 1525034560
- DB Schema: 249
- PHP: 7.0.28-0ubuntu0.16.04.1
- MySQL: 10.0.34-MariaDB-0ubuntu0.16.04.1
- RRDTool: 1.5.5
- SNMP: NET-SNMP 5.7.3
- ==================================DEBUG!
- Updating os_def.cache... Done
- SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.115.0.32' ORDER BY device_id DESC]
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '1430']
- 10.115.0.32 1430 generic SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('5','5','0','0.76','1.06','0.85','1430',NOW())]
- SNMP Check response code: 0
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- FortiwebAz
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.123*007
- | FortiwebAz | .1.3.6.1.4.1.12356.107.1.50007 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0]
- No Such Object available on this agent at this OID
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '1430' AND `attrib_type` = 'poll_mib' ]
- Attempting to initialize OS: generic
- OS initialized: LibreNMS\OS\Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0]
- .*.*.0 = FortiWeb
- .*.*.0 = .*.4.1.123*007
- .*.*.0 = FortiwebAz
- >> Runtime for discovery module 'core': 0.0090 seconds with 1032 bytes
- >> SNMP: [5/0.05s] MySQL: [10/0.17s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
- FortiwebAz
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
- .*.4.1.123*007
- | FortiwebAz | .1.3.6.1.4.1.12356.107.1.50007 |
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0]
- No Such Object available on this agent at this OID
- OS: Generic Device (generic)
- >> Runtime for discovery module 'os': 0.0300 seconds with 1368 bytes
- >> SNMP: [3/0.03s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ifDescr]
- ifDescr.1 = port1
- ifDescr.2 = port2
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ifName]
- ifName.1 = port1
- ifName.2 = port2
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ifAlias]
- ifAlias.1 = port1
- ifAlias.2 = port2
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ifType]
- ifType.1 = ethernetCsmacd
- ifType.2 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => port1
- [ifName] => port1
- [ifAlias] => port1
- [ifType] => ethernetCsmacd
- )
- [2] => Array
- (
- [ifDescr] => port2
- [ifName] => port2
- [ifAlias] => port2
- [ifType] => ethernetCsmacd
- )
- )
- SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
- SQL[SELECT * FROM `ports` WHERE `device_id` = '1430' ORDER BY port_id]
- ..
- >> Runtime for discovery module 'ports': 0.0430 seconds with 4328 bytes
- >> SNMP: [4/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '1430']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ifStackStatus]
- ifStackStatus.0.1 = active
- ifStackStatus.0.2 = active
- ifStackStatus.1.0 = active
- ifStackStatus.2.0 = active
- ....
- >> Runtime for discovery module 'ports-stack': 0.0110 seconds with 1800 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhysicalEntry]
- entPhysicalDescr.1 = Fortinet FWB_AZURE, HW Serial#: FVVM020000098501
- entPhysicalDescr.2 =
- entPhysicalDescr.3 =
- entPhysicalDescr.4 =
- entPhysicalDescr.5 =
- entPhysicalDescr.6 =
- entPhysicalDescr.7 =
- entPhysicalDescr.8 =
- entPhysicalDescr.9 =
- entPhysicalDescr.10 =
- entPhysicalDescr.11 =
- entPhysicalDescr.12 =
- entPhysicalDescr.13 =
- entPhysicalDescr.14 =
- entPhysicalDescr.15 =
- entPhysicalDescr.16 =
- entPhysicalVendorType.1 = enterprises.12356.50007.50007.0
- entPhysicalVendorType.2 = zeroDotZero.0
- entPhysicalVendorType.3 = zeroDotZero.0
- entPhysicalVendorType.4 = zeroDotZero.0
- entPhysicalVendorType.5 = zeroDotZero.0
- entPhysicalVendorType.6 = zeroDotZero.0
- entPhysicalVendorType.7 = zeroDotZero.0
- entPhysicalVendorType.8 = zeroDotZero.0
- entPhysicalVendorType.9 = zeroDotZero.0
- entPhysicalVendorType.10 = zeroDotZero.0
- entPhysicalVendorType.11 = zeroDotZero.0
- entPhysicalVendorType.12 = zeroDotZero.0
- entPhysicalVendorType.13 = zeroDotZero.0
- entPhysicalVendorType.14 = zeroDotZero.0
- entPhysicalVendorType.15 = zeroDotZero.0
- entPhysicalVendorType.16 = zeroDotZero.0
- entPhysicalContainedIn.1 = 0
- entPhysicalContainedIn.2 = 0
- entPhysicalContainedIn.3 = 0
- entPhysicalContainedIn.4 = 0
- entPhysicalContainedIn.5 = 0
- entPhysicalContainedIn.6 = 0
- entPhysicalContainedIn.7 = 0
- entPhysicalContainedIn.8 = 0
- entPhysicalContainedIn.9 = 0
- entPhysicalContainedIn.10 = 0
- entPhysicalContainedIn.11 = 0
- entPhysicalContainedIn.12 = 0
- entPhysicalContainedIn.13 = 0
- entPhysicalContainedIn.14 = 0
- entPhysicalContainedIn.15 = 0
- entPhysicalContainedIn.16 = 0
- entPhysicalClass.1 = chassis
- entPhysicalClass.2 = unknown
- entPhysicalClass.3 = unknown
- entPhysicalClass.4 = unknown
- entPhysicalClass.5 = unknown
- entPhysicalClass.6 = unknown
- entPhysicalClass.7 = unknown
- entPhysicalClass.8 = unknown
- entPhysicalClass.9 = unknown
- entPhysicalClass.10 = unknown
- entPhysicalClass.11 = unknown
- entPhysicalClass.12 = unknown
- entPhysicalClass.13 = unknown
- entPhysicalClass.14 = unknown
- entPhysicalClass.15 = unknown
- entPhysicalClass.16 = unknown
- entPhysicalParentRelPos.1 = -1
- entPhysicalParentRelPos.2 = -1
- entPhysicalParentRelPos.3 = -1
- entPhysicalParentRelPos.4 = -1
- entPhysicalParentRelPos.5 = -1
- entPhysicalParentRelPos.6 = -1
- entPhysicalParentRelPos.7 = -1
- entPhysicalParentRelPos.8 = -1
- entPhysicalParentRelPos.9 = -1
- entPhysicalParentRelPos.10 = -1
- entPhysicalParentRelPos.11 = -1
- entPhysicalParentRelPos.12 = -1
- entPhysicalParentRelPos.13 = -1
- entPhysicalParentRelPos.14 = -1
- entPhysicalParentRelPos.15 = -1
- entPhysicalParentRelPos.16 = -1
- entPhysicalName.1 = FWB_AZURE
- entPhysicalName.2 =
- entPhysicalName.3 =
- entPhysicalName.4 =
- entPhysicalName.5 =
- entPhysicalName.6 =
- entPhysicalName.7 =
- entPhysicalName.8 =
- entPhysicalName.9 =
- entPhysicalName.10 =
- entPhysicalName.11 =
- entPhysicalName.12 =
- entPhysicalName.13 =
- entPhysicalName.14 =
- entPhysicalName.15 =
- entPhysicalName.16 =
- entPhysicalHardwareRev.1 =
- entPhysicalHardwareRev.2 =
- entPhysicalHardwareRev.3 =
- entPhysicalHardwareRev.4 =
- entPhysicalHardwareRev.5 =
- entPhysicalHardwareRev.6 =
- entPhysicalHardwareRev.7 =
- entPhysicalHardwareRev.8 =
- entPhysicalHardwareRev.9 =
- entPhysicalHardwareRev.10 =
- entPhysicalHardwareRev.11 =
- entPhysicalHardwareRev.12 =
- entPhysicalHardwareRev.13 =
- entPhysicalHardwareRev.14 =
- entPhysicalHardwareRev.15 =
- entPhysicalHardwareRev.16 =
- entPhysicalFirmwareRev.1 =
- entPhysicalFirmwareRev.2 =
- entPhysicalFirmwareRev.3 =
- entPhysicalFirmwareRev.4 =
- entPhysicalFirmwareRev.5 =
- entPhysicalFirmwareRev.6 =
- entPhysicalFirmwareRev.7 =
- entPhysicalFirmwareRev.8 =
- entPhysicalFirmwareRev.9 =
- entPhysicalFirmwareRev.10 =
- entPhysicalFirmwareRev.11 =
- entPhysicalFirmwareRev.12 =
- entPhysicalFirmwareRev.13 =
- entPhysicalFirmwareRev.14 =
- entPhysicalFirmwareRev.15 =
- entPhysicalFirmwareRev.16 =
- entPhysicalSoftwareRev.1 = FWB_AZURE 5.91,build1618,180425
- entPhysicalSoftwareRev.2 =
- entPhysicalSoftwareRev.3 =
- entPhysicalSoftwareRev.4 =
- entPhysicalSoftwareRev.5 =
- entPhysicalSoftwareRev.6 =
- entPhysicalSoftwareRev.7 =
- entPhysicalSoftwareRev.8 =
- entPhysicalSoftwareRev.9 =
- entPhysicalSoftwareRev.10 =
- entPhysicalSoftwareRev.11 =
- entPhysicalSoftwareRev.12 =
- entPhysicalSoftwareRev.13 =
- entPhysicalSoftwareRev.14 =
- entPhysicalSoftwareRev.15 =
- entPhysicalSoftwareRev.16 =
- entPhysicalSerialNum.1 = FVVM020000098501
- entPhysicalSerialNum.2 =
- entPhysicalSerialNum.3 =
- entPhysicalSerialNum.4 =
- entPhysicalSerialNum.5 =
- entPhysicalSerialNum.6 =
- entPhysicalSerialNum.7 =
- entPhysicalSerialNum.8 =
- entPhysicalSerialNum.9 =
- entPhysicalSerialNum.10 =
- entPhysicalSerialNum.11 =
- entPhysicalSerialNum.12 =
- entPhysicalSerialNum.13 =
- entPhysicalSerialNum.14 =
- entPhysicalSerialNum.15 =
- entPhysicalSerialNum.16 =
- entPhysicalMfgName.1 = Fortinet
- entPhysicalMfgName.2 =
- entPhysicalMfgName.3 =
- entPhysicalMfgName.4 =
- entPhysicalMfgName.5 =
- entPhysicalMfgName.6 =
- entPhysicalMfgName.7 =
- entPhysicalMfgName.8 =
- entPhysicalMfgName.9 =
- entPhysicalMfgName.10 =
- entPhysicalMfgName.11 =
- entPhysicalMfgName.12 =
- entPhysicalMfgName.13 =
- entPhysicalMfgName.14 =
- entPhysicalMfgName.15 =
- entPhysicalMfgName.16 =
- entPhysicalModelName.1 = FWB_AZURE
- entPhysicalModelName.2 =
- entPhysicalModelName.3 =
- entPhysicalModelName.4 =
- entPhysicalModelName.5 =
- entPhysicalModelName.6 =
- entPhysicalModelName.7 =
- entPhysicalModelName.8 =
- entPhysicalModelName.9 =
- entPhysicalModelName.10 =
- entPhysicalModelName.11 =
- entPhysicalModelName.12 =
- entPhysicalModelName.13 =
- entPhysicalModelName.14 =
- entPhysicalModelName.15 =
- entPhysicalModelName.16 =
- entPhysicalAlias.1 =
- entPhysicalAlias.2 =
- entPhysicalAlias.3 =
- entPhysicalAlias.4 =
- entPhysicalAlias.5 =
- entPhysicalAlias.6 =
- entPhysicalAlias.7 =
- entPhysicalAlias.8 =
- entPhysicalAlias.9 =
- entPhysicalAlias.10 =
- entPhysicalAlias.11 =
- entPhysicalAlias.12 =
- entPhysicalAlias.13 =
- entPhysicalAlias.14 =
- entPhysicalAlias.15 =
- entPhysicalAlias.16 =
- entPhysicalAssetID.1 =
- entPhysicalAssetID.2 =
- entPhysicalAssetID.3 =
- entPhysicalAssetID.4 =
- entPhysicalAssetID.5 =
- entPhysicalAssetID.6 =
- entPhysicalAssetID.7 =
- entPhysicalAssetID.8 =
- entPhysicalAssetID.9 =
- entPhysicalAssetID.10 =
- entPhysicalAssetID.11 =
- entPhysicalAssetID.12 =
- entPhysicalAssetID.13 =
- entPhysicalAssetID.14 =
- entPhysicalAssetID.15 =
- entPhysicalAssetID.16 =
- entPhysicalIsFRU.1 = true
- entPhysicalIsFRU.2 = false
- entPhysicalIsFRU.3 = false
- entPhysicalIsFRU.4 = false
- entPhysicalIsFRU.5 = false
- entPhysicalIsFRU.6 = false
- entPhysicalIsFRU.7 = false
- entPhysicalIsFRU.8 = false
- entPhysicalIsFRU.9 = false
- entPhysicalIsFRU.10 = false
- entPhysicalIsFRU.11 = false
- entPhysicalIsFRU.12 = false
- entPhysicalIsFRU.13 = false
- entPhysicalIsFRU.14 = false
- entPhysicalIsFRU.15 = false
- entPhysicalIsFRU.16 = false
- entPhysicalMfgDate.1 =
- entPhysicalMfgDate.2 =
- entPhysicalMfgDate.3 =
- entPhysicalMfgDate.4 =
- entPhysicalMfgDate.5 =
- entPhysicalMfgDate.6 =
- entPhysicalMfgDate.7 =
- entPhysicalMfgDate.8 =
- entPhysicalMfgDate.9 =
- entPhysicalMfgDate.10 =
- entPhysicalMfgDate.11 =
- entPhysicalMfgDate.12 =
- entPhysicalMfgDate.13 =
- entPhysicalMfgDate.14 =
- entPhysicalMfgDate.15 =
- entPhysicalMfgDate.16 =
- entPhysicalUris.1 = ""
- entPhysicalUris.2 = ""
- entPhysicalUris.3 = ""
- entPhysicalUris.4 = ""
- entPhysicalUris.5 = ""
- entPhysicalUris.6 = ""
- entPhysicalUris.7 = ""
- entPhysicalUris.8 = ""
- entPhysicalUris.9 = ""
- entPhysicalUris.10 = ""
- entPhysicalUris.11 = ""
- entPhysicalUris.12 = ""
- entPhysicalUris.13 = ""
- entPhysicalUris.14 = ""
- entPhysicalUris.15 = ""
- entPhysicalUris.16 = ""
- entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entAliasMappingIdentifier]
- entAliasMappingIdentifier = No Such Object available on this agent at this OID
- SQL[SELECT entPhysical_id FROM `entPhysical` WHERE device_id = '1430' AND entPhysicalIndex = '1']
- SQL[UPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='Fortinet FWB_AZURE, HW Serial#: FVVM020000098501',`entPhysicalClass` ='chassis',`entPhysicalName` ='FWB_AZURE',`entPhysicalModelName` ='FWB_AZURE',`entPhysicalSerialNum` ='FVVM020000098501',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='Fortinet',`entPhysicalParentRelPos` ='-1',`entPhysicalVendorType` ='enterprises.12356.50007.50007.0',`entPhysicalHardwareRev` ='',`entPhysicalFirmwareRev` ='',`entPhysicalSoftwareRev` ='FWB_AZURE 5.91,build1618,180425',`entPhysicalIsFRU` ='true',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='1430' AND entPhysicalIndex='1']
- .
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '1430']
- >> Runtime for discovery module 'entity-physical': 0.0730 seconds with 8840 bytes
- >> SNMP: [1/0.04s] MySQL: [3/0.02s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global- OS- Device Module [ entity-state ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 hrProcessorLoad]
- hrProcessorLoad = No Such Object available on this agent at this OID
- UCD Resources: SQL[SELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = '1430']
- SQL[SELECT * FROM devices_attribs WHERE `device_id` = '1430']
- SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '1430']
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0]
- No Such Object available on this agent at this OID
- SQL[SELECT * FROM `processors` WHERE `device_id`='1430']
- SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL]
- >> Runtime for discovery module 'processors': 0.0240 seconds with 69760 bytes
- >> SNMP: [2/0.02s] MySQL: [5/0.00s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '1430' AND `mempool_type` = 'cemp']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp -t 2 -r 5 udp:HOSTNAME:161 hpLocal]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp -t 2 -r 5 udp:HOSTNAME:161 hpGlobal]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = No Such Object available on this agent at this OID
- SQL[SELECT * FROM `mempools` WHERE `device_id` = '1430']
- >> Runtime for discovery module 'mempools': 0.0510 seconds with 44664 bytes
- >> SNMP: [3/0.05s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '1430' ]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2696 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
- Modules status: Global- OS- Device Module [ vrf ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipAdEntIfIndex]
- ipAdEntIfIndex No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipAdEntNetMask.]
- No Such Instance currently exists at this OID
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '1430' AND `ifIndex` = '']
- !SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '1430' OR `ports`.`device_id` IS NULL]
- >> Runtime for discovery module 'ipv4-addresses': 0.0260 seconds with 41872 bytes
- >> SNMP: [2/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
- ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipv6AddrPfxLength]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '1430' OR `ports`.`device_id` IS NULL]
- >> Runtime for discovery module 'ipv6-addresses': 0.0240 seconds with 3472 bytes
- >> SNMP: [2/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS- Device Module [ route ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhysicalDescr]
- entPhysicalDescr.1 = Fortinet FWB_AZURE, HW Serial#: FVVM020000098501
- entPhysicalDescr.2 =
- entPhysicalDescr.3 =
- entPhysicalDescr.4 =
- entPhysicalDescr.5 =
- entPhysicalDescr.6 =
- entPhysicalDescr.7 =
- entPhysicalDescr.8 =
- entPhysicalDescr.9 =
- entPhysicalDescr.10 =
- entPhysicalDescr.11 =
- entPhysicalDescr.12 =
- entPhysicalDescr.13 =
- entPhysicalDescr.14 =
- entPhysicalDescr.15 =
- entPhysicalDescr.16 =
- entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhysicalName]
- entPhysicalName.1 = FWB_AZURE
- entPhysicalName.2 =
- entPhysicalName.3 =
- entPhysicalName.4 =
- entPhysicalName.5 =
- entPhysicalName.6 =
- entPhysicalName.7 =
- entPhysicalName.8 =
- entPhysicalName.9 =
- entPhysicalName.10 =
- entPhysicalName.11 =
- entPhysicalName.12 =
- entPhysicalName.13 =
- entPhysicalName.14 =
- entPhysicalName.15 =
- entPhysicalName.16 =
- entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhySensorType]
- entPhySensorType = No Such Object available on this agent at this OID
- entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhySensorScale]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhySensorPrecision]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 entPhySensorValue]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '1430' AND `attrib_type` = 'ipmi_hostname' ]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'ipmi']
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'ipmi']
- Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Delay: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Quality_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Chromatic_dispersion: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Ber: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Eer: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- Waterflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '1430' AND S.poller_type = 'snmp']
- >> Runtime for discovery module 'sensors': 0.0780 seconds with 121608 bytes
- >> SNMP: [6/0.06s] MySQL: [28/0.01s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 hrStorageEntry]
- hrStorageEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dskTable]
- dskTable = No Such Object available on this agent at this OID
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '1430' AND `storage_type` != 'dsk']
- SQL[SELECT * FROM `storage` WHERE `device_id` = '1430']
- >> Runtime for discovery module 'storage': 0.0260 seconds with 8432 bytes
- >> SNMP: [2/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 hrDeviceEntry]
- hrDeviceEntry = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 hrProcessorEntry]
- hrProcessorEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '1430']
- >> Runtime for discovery module 'hr-device': 0.0230 seconds with 3744 bytes
- >> SNMP: [2/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '1430']
- SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.0010 seconds with 4752 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipNetToPhysicalPhysAddress]
- ipNetToPhysicalPhysAddress = No Such Instance currently exists at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 ipNetToMediaPhysAddress]
- ipNetToMediaPhysAddress = No Such Instance currently exists at this OID
- SQL[SELECT * from `ipv4_mac` WHERE `device_id`='1430' AND `context_name`='']
- SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL]
- >> Runtime for discovery module 'arp-table': 0.0270 seconds with 2440 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os.
- Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module bgp-peers ####
- SNMP[/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 bgpLocalAs]
- "FortiwebAz"
- No BGP on hostPeers :
- SQL[DELETE FROM `bgpPeers` WHERE device_id='1430' AND context_name='']
- SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id='1430' AND context_name='']
- SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id='1430']
- >> Runtime for discovery module 'bgp-peers': 0.0100 seconds with 5464 bytes
- >> SNMP: [1/0.01s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module bgp-peers ####
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[SELECT * FROM `vlans` WHERE `device_id` = '1430']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dot1dBasePortIfIndex]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dot1qVlanVersionNumber.0]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.0320 seconds with 9296 bytes
- >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 diskIOEntry]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '1430']
- >> Runtime for discovery module 'ucd-diskio': 0.0110 seconds with 3120 bytes
- >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS- Device Module [ applications ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS+ Device
- #### Load disco module stp ####
- SQL[SELECT * FROM `stp` WHERE `device_id` = '1430']
- SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dot1dStpProtocolSpecification.0]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'stp': 0.0110 seconds with 5904 bytes
- >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module stp ####
- Modules status: Global+ OS+ Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 0.0000 seconds with 136 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
- Modules status: Global- OS- Device Module [ mef ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module wireless ####
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='ap-count']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='clients']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='quality']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='capacity']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='utilization']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='rate']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='ccq']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='snr']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='ssr']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='mse']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='rssi']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='power']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='noise-floor']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='errors']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='error-ratio']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='error-rate']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='frequency']
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='1430' AND `sensor_class`='distance']
- >> Runtime for discovery module 'wireless': 0.0070 seconds with 120464 bytes
- >> SNMP: [0/0.00s] MySQL: [18/0.01s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '1430']
- SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = '1430']
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dot1qTpFdbPort]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs -t 2 -r 5 udp:HOSTNAME:161 dot1dTpFdbPort]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.0300 seconds with 3072 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '1430' AND `attrib_type` = 'poll_mib' ]
- SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='4.62' WHERE `device_id` = '1430']
- Discovered in 4.62 seconds
- SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','10.115.0.32','1525274342.2794','4.765','1','AzPrdLibreNMS01')]
- /opt/librenms/discovery.php 10.115.0.32 2018-05-02 09:19:07 - 1 devices discovered in 4.765 secs
- SNMP [37/0.45s]: Get[12/0.13s] Getnext[1/0.01s] Walk[24/0.32s]
- MySQL [91/0.24s]: Cell[7/0.00s] Row[5/0.00s] Rows[67/0.02s] Column[2/0.00s] Update[3/0.20s] Insert[2/0.02s] Delete[5/0.00s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]