- -bash-4.2$ ./discovery.php -h tlups1 -d | ./pbin.sh
- Paste endpoint: https://p.libren.ms/api/create
- SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 0.92ms]
- SQL[select count(*) as aggregate from `migrations` limit 1 [] 0.51ms]
- SQL[SELECT version() [] 0.4ms]
- Updating os_def.cache...
- Done
- SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'tlups1' ORDER BY device_id DESC [] 4.36ms]
- SQL[select * from `devices` where `device_id` = ? limit 1 [30] 3.22ms]
- SQL[select * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [30] 1.95ms]
- [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' 'tlups1'
- array (
- 'xmt' => 3,
- 'rcv' => 3,
- 'loss' => 0,
- 'min' => 1.31,
- 'max' => 10.8,
- 'avg' => 4.59,
- 'dup' => 0,
- 'exitcode' => 0,
- )
- SQL[INSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) {"xmt":3,"rcv":3,"loss":0,"min":1.31,"max":10.8,"avg":4.59,"device_id":30,"debug":"[]"} 1.53ms]
- SNMP Check response code: 0
- Attempting to initialize OS: poweralert
- OS initialized as Generic
- Modules status: Global+
- OS
- Device
- .*.*.0 = tlup1.int.dittman.net
- .*.*.0 = .*.4.1.850.1
- .*.*.0 = POWERALERT 12
- Modules status: Global+
- OS+
- Device
- POWERALERT 12
- .*.4.1.850.1
- | POWERALERT 12 | .1.3.6.1.4.1.850.1 |
- No Such Object available on this agent at this OID
- No Such Object available on this agent at this OID
- No Such Object available on this agent at this OID
- No Such Object available on this agent at this OID
- No Such Instance currently exists at this OID
- Modules status: Global+
- OS+
- Device
- ifDescr.1 = lo
- ifDescr.2 = eth0
- ifDescr.3 = ppp0
- ifDescr.4 = ppp1
- ifName = No Such Object available on this agent at this OID
- ifAlias = No Such Object available on this agent at this OID
- ifType.1 = other
- ifType.2 = iso88023Csmacd
- ifType.3 = ppp
- ifType.4 = ppp
- array (
- 1 =>
- array (
- 'ifDescr' => 'lo',
- 'ifType' => 'other',
- ),
- 2 =>
- array (
- 'ifDescr' => 'eth0',
- 'ifType' => 'iso88023Csmacd',
- ),
- 3 =>
- array (
- 'ifDescr' => 'ppp0',
- 'ifType' => 'ppp',
- ),
- 4 =>
- array (
- 'ifDescr' => 'ppp1',
- 'ifType' => 'ppp',
- ),
- )
- SQL[SELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [30] 1.38ms]
- Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["lo","other",1,"lo","lo",188] 9.14ms]
- Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["eth0","iso88023Csmacd",2,"eth0","eth0",189] 7.39ms]
- Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["ppp0","ppp",3,"ppp0","ppp0",190] 1.01ms]
- Using ifDescr as ifAlias
- Using ifDescr as ifName
- SQL[UPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? ["ppp1","ppp",4,"ppp1","ppp1",191] 0.96ms]
- Modules status: Global+
- OS+
- Device
- SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '30' [] 0.5ms]
- ifStackStatus = No Such Object available on this agent at this OID
- Modules status: Global+
- OS+
- Device
- entPhysicalEntry = No Such Object available on this agent at this OID
- SQL[SELECT * FROM `entPhysical` WHERE `device_id` = ? [30] 0.91ms]
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- No YAML Discovery data.
- hrProcessorLoad = No Such Object available on this agent at this OID
- SQL[select * from `locations` where `locations`.`id` = ? limit 1 [5] 0.62ms]
- SQL[select * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [30] 0.78ms]
- No Such Object available on this agent at this OID
- SQL[SELECT * FROM `processors` WHERE `device_id`=? [30] 0.87ms]
- SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 0.7ms]
- Modules status: Global+
- OS+
- Device
- SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [30] 0.52ms]
- dellNetCpuUtilTable = No Such Object available on this agent at this OID
- dellNetProcessorEntry = No Such Object available on this agent at this OID
- hpLocalMem = No Such Object available on this agent at this OID
- hpGlobalMem = No Such Object available on this agent at this OID
- hrStorageEntry = No Such Object available on this agent at this OID
- memoryUsageTable = No Such Object available on this agent at this OID
- memStatsTable = No Such Object available on this agent at this OID
- SQL[SELECT * FROM `mempools` WHERE `device_id` = '30' [] 0.97ms]
- Modules status: Global+
- OS+
- Device
- SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = ? [30] 0.47ms]
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- ipAdEntIfIndex.* 1
- ipAdEntIfIndex.* 2
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [30,"1"] 0.88ms]
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [30,"1"] 0.62ms]
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.59ms]
- SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [null,"127.0.0.0\/8"] 11.43ms]
- SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["127.0.0.0\/8"] 0.55ms]
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["127.0.0.1",8,188] 0.56ms]
- SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [null,"127.0.0.1",8,188] 6.21ms]
- *
- SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [30,"2"] 0.77ms]
- SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [30,"2"] 0.56ms]
- SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? ["192.94.152.0\/24"] 0.53ms]
- SQL[UPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [null,"192.94.152.0\/24"] 1.12ms]
- SQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? ["192.94.152.0\/24"] 0.55ms]
- SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? ["192.94.152.251",24,189] 0.62ms]
- SQL[UPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [null,"192.94.152.251",24,189] 0.97ms]
- SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [30] 0.93ms]
- Modules status: Global+
- OS+
- Device
- ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [30] 0.96ms]
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- 9725AY0AC699600158
- array (
- 'poweralert_serial' => '9725AY0AC699600158',
- )
- entPhysicalDescr = No Such Instance currently exists at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",30,"ipmi"] 1.98ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",30,"ipmi"] 1.15ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",30,"ipmi"] 1.01ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",30,"ipmi"] 1.02ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",30,"snmp"] 0.98ms]
- No Such Instance currently exists at this OID
- upsOutputCurrent[1] = No Such Instance currently exists at this OID
- upsInputCurrent[1] = No Such Instance currently exists at this OID
- upsBypassCurrent[1] = No Such Instance currently exists at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",30,"snmp"] 1.42ms]
- 100
- Discover sensor: .1.3.6.1.2.1.33.1.2.4.0, 500, rfc1628, Battery charge remaining, snmp, 1, 1, , 100, (limits: LL: 15, LW: 50, W: , H: 101)
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","charge",30,"rfc1628","500"] 0.93ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["charge",30,"rfc1628","500"] 0.77ms]
- array (
- 'rfc1628' =>
- array (
- 500 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",30,"snmp"] 1.09ms]
- 500 -> rfc1628
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",30,"snmp"] 0.96ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",30,"snmp"] 0.97ms]
- upsInputFrequency[1] = 600
- Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.2.1, 3.2.0.1, rfc1628, Input, snmp, 10, 1, , 60, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","frequency",30,"rfc1628","3.2.0.1"] 1.17ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["frequency",30,"rfc1628","3.2.0.1"] 1ms]
- 600
- Discover sensor: .1.3.6.1.2.1.33.1.4.2.0, 4.2.0, rfc1628, Output, snmp, 10, 1, , 60, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","frequency",30,"rfc1628","4.2.0"] 1.07ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["frequency",30,"rfc1628","4.2.0"] 0.93ms]
- 600
- Discover sensor: .1.3.6.1.2.1.33.1.5.1.0, 5.1.0, rfc1628, Bypass, snmp, 10, 1, , 60, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","frequency",30,"rfc1628","5.1.0"] 1.1ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["frequency",30,"rfc1628","5.1.0"] 0.92ms]
- array (
- 'rfc1628' =>
- array (
- '3.2.0.1' => 1,
- '4.2.0' => 1,
- '5.1.0' => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",30,"snmp"] 1.31ms]
- 3.2.0.1 -> rfc1628
- 4.2.0 -> rfc1628
- 5.1.0 -> rfc1628
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",30,"snmp"] 1.1ms]
- upsOutputPercentLoad[1] = 25
- Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.5.1, 501, rfc1628, Percentage load, snmp, 1, 1, , 25, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","load",30,"rfc1628","501"] 0.89ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["load",30,"rfc1628","501"] 0.81ms]
- array (
- 'rfc1628' =>
- array (
- 501 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",30,"snmp"] 1.11ms]
- 501 -> rfc1628
- upsOutputPower[1] = No Such Instance currently exists at this OID
- upsInputTruePower[1] = No Such Instance currently exists at this OID
- upsBypassPower[1] = No Such Instance currently exists at this OID
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",30,"snmp"] 1.36ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",30,"snmp"] 1.05ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",30,"snmp"] 1.06ms]
- 0
- Discover sensor: .1.3.6.1.2.1.33.1.2.2.0, 100, rfc1628, Time on battery, snmp, 60, 1, , 0, (limits: LL: 0, LW: 0, W: 1, H: 2)
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","runtime",30,"rfc1628","100"] 0.92ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["runtime",30,"rfc1628","100"] 0.82ms]
- 30
- Discover sensor: .1.3.6.1.2.1.33.1.2.3.0, 200, rfc1628, Estimated battery time remaining, snmp, 1, 1, , 30, (limits: LL: 5, LW: 10, W: , H: 10000)
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","runtime",30,"rfc1628","200"] 1.02ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["runtime",30,"rfc1628","200"] 0.87ms]
- array (
- 'rfc1628' =>
- array (
- 100 => 1,
- 200 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",30,"snmp"] 1.2ms]
- 100 -> rfc1628
- 200 -> rfc1628
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",30,"snmp"] 0.95ms]
- 2
- SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["upsBatteryStatusState"] 0.79ms]
- SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [43] 0.72ms]
- Discover sensor: .1.3.6.1.2.1.33.1.2.1.0, 0, upsBatteryStatusState, Battery Status, snmp, 1, 1, 0, 2, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","state",30,"upsBatteryStatusState","0"] 0.76ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["state",30,"upsBatteryStatusState","0"] 0.86ms]
- SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["state",30,"upsBatteryStatusState",0] 0.75ms]
- SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? ["upsBatteryStatusState"] 0.6ms]
- SQL[INSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) {"sensor_id":38,"state_index_id":43} 1.28ms]
- 3
- SQL[SELECT `state_index_id` FROM state_indexes WHERE state_name = ? LIMIT 1 ["upsOutputSourceState"] 0.77ms]
- SQL[SELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`=? [44] 0.71ms]
- Discover sensor: .1.3.6.1.2.1.33.1.4.1.0, 0, upsOutputSourceState, Output Source, snmp, 1, 1, 0, 3, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","state",30,"upsOutputSourceState","0"] 0.77ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["state",30,"upsOutputSourceState","0"] 0.86ms]
- SQL[SELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["state",30,"upsOutputSourceState",0] 0.74ms]
- SQL[SELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? ["upsOutputSourceState"] 0.58ms]
- SQL[INSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) {"sensor_id":39,"state_index_id":44} 1.24ms]
- array (
- 'upsBatteryStatusState' =>
- array (
- 0 => 1,
- ),
- 'upsOutputSourceState' =>
- array (
- 0 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",30,"snmp"] 1.23ms]
- 0 -> upsBatteryStatusState
- 0 -> upsOutputSourceState
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",30,"snmp"] 0.95ms]
- 42
- Discover sensor: .1.3.6.1.2.1.33.1.2.7.0, 0, rfc1628, Battery, snmp, 1, 1, , 42, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","temperature",30,"rfc1628","0"] 1.03ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["temperature",30,"rfc1628","0"] 0.94ms]
- array (
- 'rfc1628' =>
- array (
- 0 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",30,"snmp"] 1.18ms]
- 0 -> rfc1628
- 540
- Discover sensor: .1.3.6.1.2.1.33.1.2.5.0, 1.2.5.0, rfc1628, Battery, snmp, 10, 1, , 54, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",30,"rfc1628","1.2.5.0"] 1.01ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",30,"rfc1628","1.2.5.0"] 0.93ms]
- upsOutputVoltage[1] = 119
- Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.2.1, 1, rfc1628, Output, snmp, 1, 1, , 119, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",30,"rfc1628","1"] 1.08ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",30,"rfc1628","1"] 0.93ms]
- upsInputVoltage[1] = 124
- Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.3.1, 101, rfc1628, Input, snmp, 1, 1, , 124, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",30,"rfc1628","101"] 1.06ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",30,"rfc1628","101"] 0.89ms]
- upsBypassVoltage[1] = 124
- Discover sensor: .1.3.6.1.2.1.33.1.5.3.1.2.1, 201, rfc1628, Bypass, snmp, 1, 1, , 124, (limits: LL: , LW: , W: , H: )
- SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? ["snmp","voltage",30,"rfc1628","201"] 0.97ms]
- SQL[SELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? ["voltage",30,"rfc1628","201"] 0.83ms]
- array (
- 'rfc1628' =>
- array (
- '1.2.5.0' => 1,
- 1 => 1,
- 101 => 1,
- 201 => 1,
- ),
- )
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",30,"snmp"] 1.2ms]
- 1.2.5.0 -> rfc1628
- 1 -> rfc1628
- 101 -> rfc1628
- 201 -> rfc1628
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",30,"snmp"] 0.97ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",30,"snmp"] 0.99ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",30,"snmp"] 0.95ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",30,"snmp"] 0.9ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",30,"snmp"] 0.91ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",30,"snmp"] 0.9ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",30,"snmp"] 0.9ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",30,"snmp"] 0.9ms]
- SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",30,"snmp"] 1ms]
- Modules status: Global+
- OS+
- Device
- MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/poweralert
- Cannot find module (IBM-AIX-MIB): At line 1 in (none)
- aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry)
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '30' AND `storage_type` != 'aixFileSystem' [] 0.73ms]
- fileSystemSpaceTable = No Such Object available on this agent at this OID
- hrStorageEntry = No Such Object available on this agent at this OID
- dskTable = No Such Object available on this agent at this OID
- SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '30' AND `storage_type` != 'dsk' [] 0.74ms]
- SQL[SELECT * FROM `storage` WHERE `device_id` = '30' [] 0.55ms]
- Modules status: Global+
- OS+
- Device
- hrDeviceEntry = No Such Object available on this agent at this OID
- hrProcessorEntry = No Such Object available on this agent at this OID
- array (
- )
- SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '30' [] 0.82ms]
- Modules status: Global+
- OS+
- Device
- cdpCache = No Such Object available on this agent at this OID
- lldpRemTable = No Such Object available on this agent at this OID
- SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [30] 0.81ms]
- SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [30] 1.11ms]
- SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 0.52ms]
- 0 orphaned links deleted
- Modules status: Global+
- OS+
- Device
- ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
- ipNetToMediaPhysAddress = No Such Instance currently exists at this OID
- SQL[SELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [30,""] 1.35ms]
- SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [] 1.44ms]
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- "Tripp Lite"
- Peers :
- SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [30,""] 0.57ms]
- SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [30,""] 0.44ms]
- SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [30] 0.61ms]
- Modules status: Global+
- OS+
- Device
- SQL[SELECT * FROM `vlans` WHERE `device_id` = ? [30] 0.55ms]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- No Such Object available on this agent at this OID
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- diskIOEntry = No Such Object available on this agent at this OID
- array (
- )
- SQL[SELECT * FROM `ucd_diskio` where `device_id` = '30' [] 0.65ms]
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- Modules status: Global+
- OS+
- Device
- SQL[SELECT * FROM `stp` WHERE `device_id` = ? [30] 0.53ms]
- No Such Object available on this agent at this OID
- Modules status: Global+
- OS+
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global-
- OS-
- Device
- Modules status: Global+
- OS+
- Device
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"ap-count"] 0.95ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"clients"] 0.64ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"quality"] 0.67ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"capacity"] 0.65ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"utilization"] 0.65ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"rate"] 0.65ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"ccq"] 0.78ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"snr"] 0.72ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"sinr"] 0.7ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"rsrp"] 0.73ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"rsrq"] 0.7ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"ssr"] 0.7ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"mse"] 0.7ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"xpi"] 0.69ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"rssi"] 0.75ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"power"] 0.68ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"noise-floor"] 0.66ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"errors"] 0.66ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"error-ratio"] 0.59ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"error-rate"] 0.67ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"frequency"] 0.67ms]
- SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [30,"distance"] 0.7ms]
- Modules status: Global+
- OS+
- Device
- SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [30] 0.49ms]
- SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = ? [30] 0.53ms]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- Modules status: Global+
- OS+
- Device
- SQL[UPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [7.143,30] 1.43ms]
- SQL[INSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) {"type":"discover","doing":"tlups1","start":1577149261.115333,"duration":"7.682","devices":1,"poller":"librenms.int.dittman.net"} 0.92ms]
- ./discovery.php tlups1 2019-12-23 19:01:08 - 1 devices discovered in 7.682 secs