From pmusolino, 5 Years ago, written in Plain Text.
Embed
  1. Note, using MERAKI-CLOUD-CONTROLLER mibs
  2.  
  3. LibreNMS Discovery
  4. ===================================
  5. Version info:
  6. Commit SHA: 7eb107acb961e2e67b648581ce0842728ab5f73c
  7. Commit Date: 1528326046
  8. DB Schema: 251
  9. PHP: 7.2.5
  10. MySQL: 5.5.56-MariaDB
  11. RRDTool: 1.4.8
  12. SNMP: NET-SNMP 5.7.2
  13. ==================================DEBUG!
  14. Updating os_def.cache... Done
  15. SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'snmp.meraki.com' ORDER BY device_id DESC]
  16. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '24']
  17. snmp.meraki.com 24 generic SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','37.8','37.9','37.8','24',NOW())]
  18. SNMP Check response code: 0
  19. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:16100 SNMPv2-MIB::sysDescr.0]
  20. Cisco Meraki Cloud Controller
  21.  
  22. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:16100 SNMPv2-MIB::sysObjectID.0]
  23. .*.4.1.29671.1
  24.  
  25. | Cisco Meraki Cloud Controller | .1.3.6.1.4.1.29671.1 |
  26. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:16100 .1.3.6.1.4.1.12148.10.2.6.0]
  27. No Such Object available on this agent at this OID
  28.  
  29. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '24' AND `attrib_type` = 'poll_mib' ]
  30. Attempting to initialize OS: generic
  31. OS initialized: LibreNMS\OS\Generic
  32.  
  33. Modules status: Global+ OS  Device  
  34. #### Load disco module core ####
  35. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 sysName.0 sysObjectID.0 sysDescr.0]
  36. .*.*.0 = dashboard.meraki.com
  37. .*.*.0 = .*.4.1.29671.1
  38. .*.*.0 = Cisco Meraki Cloud Controller
  39.  
  40.  
  41. >> Runtime for discovery module 'core': 0.0850 seconds with 1048 bytes
  42. >> SNMP: [5/0.51s] MySQL: [8/0.01s] RRD: [0/0.00s]
  43. #### Unload disco module core ####
  44.  
  45. Modules status: Global+ OS+ Device  
  46. #### Load disco module os ####
  47. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:16100 SNMPv2-MIB::sysDescr.0]
  48. Cisco Meraki Cloud Controller
  49.  
  50. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:16100 SNMPv2-MIB::sysObjectID.0]
  51. .*.4.1.29671.1
  52.  
  53. | Cisco Meraki Cloud Controller | .1.3.6.1.4.1.29671.1 |
  54. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:16100 .1.3.6.1.4.1.12148.10.2.6.0]
  55. No Such Object available on this agent at this OID
  56.  
  57. OS: Generic Device (generic)
  58.  
  59. >> Runtime for discovery module 'os': 0.3050 seconds with 1320 bytes
  60. >> SNMP: [3/0.30s] MySQL: [0/0.00s] RRD: [0/0.00s]
  61. #### Unload disco module os ####
  62.  
  63. Modules status: Global+ OS+ Device  
  64. #### Load disco module ports ####
  65. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ifDescr]
  66. ifDescr = No Such Object available on this agent at this OID
  67.  
  68. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ifName]
  69. ifName = No Such Object available on this agent at this OID
  70.  
  71. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ifAlias]
  72. ifAlias = No Such Object available on this agent at this OID
  73.  
  74. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ifType]
  75. ifType = No Such Object available on this agent at this OID
  76.  
  77. Array
  78. (
  79. )
  80. SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
  81. SQL[SELECT * FROM `ports` WHERE `device_id` = '24' ORDER BY port_id]
  82.  
  83.  
  84. >> Runtime for discovery module 'ports': 0.6660 seconds with 4048 bytes
  85. >> SNMP: [4/0.66s] MySQL: [2/0.00s] RRD: [0/0.00s]
  86. #### Unload disco module ports ####
  87.  
  88. Modules status: Global+ OS+ Device  
  89. #### Load disco module ports-stack ####
  90. SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '24']
  91. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ifStackStatus]
  92. ifStackStatus = No Such Object available on this agent at this OID
  93.  
  94.  
  95.  
  96. >> Runtime for discovery module 'ports-stack': 0.1620 seconds with 1768 bytes
  97. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  98. #### Unload disco module ports-stack ####
  99.  
  100. Modules status: Global+ OS+ Device  
  101. #### Load disco module entity-physical ####
  102.  
  103. Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 entPhysicalEntry]
  104. entPhysicalEntry = No Such Object available on this agent at this OID
  105.  
  106.  
  107. SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '24']
  108.  
  109. >> Runtime for discovery module 'entity-physical': 0.1790 seconds with 5184 bytes
  110. >> SNMP: [1/0.18s] MySQL: [1/0.00s] RRD: [0/0.00s]
  111. #### Unload disco module entity-physical ####
  112.  
  113. Modules status: Global- OS- Device  Module [ entity-state ] disabled on os.
  114.  
  115. Modules status: Global+ OS+ Device  
  116. #### Load disco module processors ####
  117. No YAML Discovery data.
  118. Host Resources: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 hrProcessorLoad]
  119. hrProcessorLoad = No Such Object available on this agent at this OID
  120.  
  121. UCD Resources: SQL[SELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = '24']
  122. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '24']
  123. SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '24']
  124. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:16100 .1.3.6.1.4.1.2021.11.11.0]
  125. No Such Object available on this agent at this OID
  126.  
  127. SQL[SELECT * FROM `processors` WHERE `device_id`='24']
  128. SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL]
  129.  
  130.  
  131. >> Runtime for discovery module 'processors': 0.2690 seconds with 145920 bytes
  132. >> SNMP: [2/0.27s] MySQL: [5/0.00s] RRD: [0/0.00s]
  133. #### Unload disco module processors ####
  134.  
  135. Modules status: Global+ OS+ Device  
  136. #### Load disco module mempools ####
  137. SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '24' AND `mempool_type` = 'cemp']
  138. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:16100 hpLocal]
  139. hpLocalMem = No Such Object available on this agent at this OID
  140.  
  141. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:16100 hpGlobal]
  142. hpGlobalMem = No Such Object available on this agent at this OID
  143.  
  144. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 hrStorageEntry]
  145. hrStorageEntry = No Such Object available on this agent at this OID
  146.  
  147. SQL[SELECT * FROM `mempools` WHERE `device_id`  = '24']
  148.  
  149.  
  150. >> Runtime for discovery module 'mempools': 0.5040 seconds with 36208 bytes
  151. >> SNMP: [3/0.50s] MySQL: [2/0.00s] RRD: [0/0.00s]
  152. #### Unload disco module mempools ####
  153.  
  154. Modules status: Global+ OS+ Device  
  155. #### Load disco module cisco-vrf-lite ####
  156. SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '24' ]
  157.  
  158. >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 2640 bytes
  159. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  160. #### Unload disco module cisco-vrf-lite ####
  161.  
  162. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  163.  
  164. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  165.  
  166. Modules status: Global- OS- Device  Module [ vrf ] disabled on os.
  167.  
  168. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  169.  
  170. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  171.  
  172. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  173.  
  174. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  175.  
  176. Modules status: Global+ OS+ Device  
  177. #### Load disco module ipv4-addresses ####
  178. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipAdEntIfIndex]
  179. ipAdEntIfIndex No Such Object available on this agent at this OID
  180.  
  181. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipAdEntNetMask.]
  182. No Such Object available on this agent at this OID
  183.  
  184. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '24' AND `ifIndex` = '']
  185. !SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '24' OR `ports`.`device_id` IS NULL]
  186.  
  187.  
  188. >> Runtime for discovery module 'ipv4-addresses': 0.2580 seconds with 33592 bytes
  189. >> SNMP: [2/0.26s] MySQL: [2/0.00s] RRD: [0/0.00s]
  190. #### Unload disco module ipv4-addresses ####
  191.  
  192. Modules status: Global+ OS+ Device  
  193. #### Load disco module ipv6-addresses ####
  194. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipAddressIfIndex.ipv6]
  195. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  196.  
  197. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipv6AddrPfxLength]
  198. .*.*.8.1.2 No Such Object available on this agent at this OID
  199.  
  200. SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '24' OR `ports`.`device_id` IS NULL]
  201.  
  202.  
  203. >> Runtime for discovery module 'ipv6-addresses': 0.3340 seconds with 3472 bytes
  204. >> SNMP: [2/0.33s] MySQL: [1/0.00s] RRD: [0/0.00s]
  205. #### Unload disco module ipv6-addresses ####
  206.  
  207. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  208.  
  209. Modules status: Global+ OS+ Device  
  210. #### Load disco module sensors ####
  211.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 entPhysicalDescr]
  212. entPhysicalDescr = No Such Object available on this agent at this OID
  213.  
  214.  
  215. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '24' AND `attrib_type` = 'ipmi_hostname' ]
  216. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'ipmi']
  217. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'ipmi']
  218. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'ipmi']
  219. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'ipmi']
  220. Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  221.  
  222. Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  223.  
  224. Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  225.  
  226. Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  227.  
  228. Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  229.  
  230. Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  231.  
  232. Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  233.  
  234. Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  235.  
  236. Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  237.  
  238. Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  239.  
  240. Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  241.  
  242. State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  243.  
  244. Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  245.  
  246. Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  247.  
  248. Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  249.  
  250. Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  251.  
  252. Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  253.  
  254. Delay: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  255.  
  256. Quality_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  257.  
  258. Chromatic_dispersion: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  259.  
  260. Ber: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  261.  
  262. Eer: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  263.  
  264. Waterflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '24' AND S.poller_type = 'snmp']
  265.  
  266.  
  267. >> Runtime for discovery module 'sensors': 0.1820 seconds with 44440 bytes
  268. >> SNMP: [1/0.16s] MySQL: [28/0.02s] RRD: [0/0.00s]
  269. #### Unload disco module sensors ####
  270.  
  271. Modules status: Global+ OS+ Device  
  272. #### Load disco module storage ####
  273. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 hrStorageEntry]
  274. hrStorageEntry = No Such Object available on this agent at this OID
  275.  
  276. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dskTable]
  277. dskTable = No Such Object available on this agent at this OID
  278.  
  279. SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id`  = '24' AND `storage_type` != 'dsk']
  280. SQL[SELECT * FROM `storage` WHERE `device_id`  = '24']
  281.  
  282.  
  283. >> Runtime for discovery module 'storage': 0.3270 seconds with 8376 bytes
  284. >> SNMP: [2/0.32s] MySQL: [2/0.00s] RRD: [0/0.00s]
  285. #### Unload disco module storage ####
  286.  
  287. Modules status: Global+ OS+ Device  
  288. #### Load disco module hr-device ####
  289. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:16100 hrDeviceEntry]
  290. hrDeviceEntry = No Such Object available on this agent at this OID
  291.  
  292. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:16100 hrProcessorEntry]
  293. hrProcessorEntry = No Such Object available on this agent at this OID
  294.  
  295. Array
  296. (
  297. )
  298. SQL[SELECT * FROM `hrDevice` WHERE `device_id`  = '24']
  299.  
  300.  
  301. >> Runtime for discovery module 'hr-device': 0.3270 seconds with 3744 bytes
  302. >> SNMP: [2/0.33s] MySQL: [1/0.00s] RRD: [0/0.00s]
  303. #### Unload disco module hr-device ####
  304.  
  305. Modules status: Global+ OS+ Device  
  306. #### Load disco module discovery-protocols ####
  307.  CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 cdpCache]
  308. cdpCache = No Such Object available on this agent at this OID
  309.  
  310.  
  311.  LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 lldpRemTable]
  312. lldpRemTable = No Such Object available on this agent at this OID
  313.  
  314.  
  315.  OSPF Discovery: SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='24']
  316.  
  317. SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '24']
  318. SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL]
  319.  0 orphaned links deleted
  320.  
  321. >> Runtime for discovery module 'discovery-protocols': 0.3370 seconds with 4848 bytes
  322. >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
  323. #### Unload disco module discovery-protocols ####
  324.  
  325. Modules status: Global+ OS+ Device  
  326. #### Load disco module arp-table ####
  327. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipNetToPhysicalPhysAddress]
  328. ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
  329.  
  330. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 ipNetToMediaPhysAddress]
  331. ipNetToMediaPhysAddress = No Such Object available on this agent at this OID
  332.  
  333. SQL[SELECT * from `ipv4_mac` WHERE `device_id`='24' AND `context_name`='']
  334. SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL]
  335.  
  336.  
  337. >> Runtime for discovery module 'arp-table': 0.3340 seconds with 2360 bytes
  338. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  339. #### Unload disco module arp-table ####
  340.  
  341. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  342.  
  343. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  344.  
  345. Modules status: Global+ OS+ Device  
  346. #### Load disco module bgp-peers ####
  347. SNMP[/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 bgpLocalAs]
  348. "RMS"
  349.  
  350. No BGP on hostPeers :
  351. SQL[DELETE FROM `bgpPeers` WHERE device_id='24' AND context_name='']
  352. SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id='24' AND context_name='']
  353.  
  354. SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id='24']
  355.  
  356. >> Runtime for discovery module 'bgp-peers': 0.0900 seconds with 5456 bytes
  357. >> SNMP: [1/0.09s] MySQL: [3/0.00s] RRD: [0/0.00s]
  358. #### Unload disco module bgp-peers ####
  359.  
  360. Modules status: Global+ OS+ Device  
  361. #### Load disco module vlans ####
  362. SQL[SELECT * FROM `vlans` WHERE `device_id` = '24']
  363. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dot1dBasePortIfIndex]
  364. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  365.  
  366. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dot1qVlanVersionNumber.0]
  367. No Such Object available on this agent at this OID
  368.  
  369.  
  370.  
  371. >> Runtime for discovery module 'vlans': 0.2670 seconds with 9296 bytes
  372. >> SNMP: [2/0.27s] MySQL: [1/0.00s] RRD: [0/0.00s]
  373. #### Unload disco module vlans ####
  374.  
  375. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  376.  
  377. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  378.  
  379. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  380.  
  381. Modules status: Global+ OS+ Device  
  382. #### Load disco module ucd-diskio ####
  383. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 diskIOEntry]
  384. diskIOEntry = No Such Object available on this agent at this OID
  385.  
  386. Array
  387. (
  388. )
  389. SQL[SELECT * FROM `ucd_diskio` where `device_id`  = '24']
  390.  
  391.  
  392. >> Runtime for discovery module 'ucd-diskio': 0.1600 seconds with 3080 bytes
  393. >> SNMP: [1/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s]
  394. #### Unload disco module ucd-diskio ####
  395.  
  396. Modules status: Global- OS- Device  Module [ applications ] disabled on os.
  397.  
  398. Modules status: Global+ OS+ Device  
  399. #### Load disco module services ####
  400.  
  401. >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
  402. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  403. #### Unload disco module services ####
  404.  
  405. Modules status: Global+ OS+ Device  
  406. #### Load disco module stp ####
  407. SQL[SELECT * FROM `stp` WHERE `device_id` = '24']
  408. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dot1dStpProtocolSpecification.0]
  409. No Such Object available on this agent at this OID
  410.  
  411.  
  412.  
  413. >> Runtime for discovery module 'stp': 0.0850 seconds with 5904 bytes
  414. >> SNMP: [1/0.08s] MySQL: [1/0.00s] RRD: [0/0.00s]
  415. #### Unload disco module stp ####
  416.  
  417. Modules status: Global+ OS+ Device  
  418. #### Load disco module ntp ####
  419.  
  420. >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
  421. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  422. #### Unload disco module ntp ####
  423.  
  424. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  425.  
  426. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  427.  
  428. Modules status: Global+ OS+ Device  
  429. #### Load disco module wireless ####
  430. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='ap-count']
  431. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='clients']
  432. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='quality']
  433. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='capacity']
  434. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='utilization']
  435. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='rate']
  436. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='ccq']
  437. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='snr']
  438. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='ssr']
  439. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='mse']
  440. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='rssi']
  441. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='power']
  442. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='noise-floor']
  443. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='errors']
  444. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='error-ratio']
  445. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='error-rate']
  446. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='frequency']
  447. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='24' AND `sensor_class`='distance']
  448.  
  449. >> Runtime for discovery module 'wireless': 0.0070 seconds with 415288 bytes
  450. >> SNMP: [0/0.00s] MySQL: [18/0.00s] RRD: [0/0.00s]
  451. #### Unload disco module wireless ####
  452.  
  453. Modules status: Global+ OS+ Device  
  454. #### Load disco module fdb-table ####
  455. SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '24']
  456. SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = '24']
  457. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dot1qTpFdbPort]
  458. dot1qTpFdbPort = No Such Object available on this agent at this OID
  459.  
  460. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:16100 dot1dTpFdbPort]
  461. dot1dTpFdbPort = No Such Object available on this agent at this OID
  462.  
  463.  
  464.  
  465. >> Runtime for discovery module 'fdb-table': 0.3300 seconds with 3000 bytes
  466. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  467. #### Unload disco module fdb-table ####
  468.  
  469. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '24' AND `attrib_type` = 'poll_mib' ]
  470. SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.722' WHERE `device_id` = '24']
  471. Discovered in 6.722 seconds
  472.  
  473. SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','snmp.meraki.com','1528400782.0805','6.875','1','nj1-off-net02')]
  474. /opt/librenms/discovery.php snmp.meraki.com 2018-06-07 15:46:28 - 1 devices discovered in 6.875 secs
  475. SNMP [32/4.41s]: Get[12/1.19s] Getnext[1/0.09s] Walk[19/3.14s]
  476. MySQL [88/0.05s]: Cell[5/0.00s] Row[5/0.00s] Rows[68/0.03s] Column[2/0.00s] Update[1/0.00s] Insert[2/0.00s] Delete[5/0.00s]
  477. RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]
  478.  
  479.