LibreNMS Discovery SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.31ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.16ms] =================================== Version info: Commit SHA: c7152294ad701323e9034a20cd6793e4e6c5ebdb Commit Date: 1544059166 DB Schema: 273 PHP: 7.0.30-0+deb9u1 MySQL: 10.1.26-MariaDB-0+deb9u1 RRDTool: 1.6.0 SNMP: NET-SNMP 5.7.3 ==================================DEBUG! Updating os_def.cache... Done SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'sonoma-edge' ORDER BY device_id DESC [0;33m[][0m 1.13ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[7][0m 0.16ms] sonoma-edge 7 iosxe [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 sonoma-edge Array ( [xmt] => 3 [rcv] => 3 [loss] => 0 [min] => 0.86 [max] => 1.73 [avg] => 1.19 [exitcode] => 0 ) SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.86","max":"1.73","avg":"1.19","device_id":7,"debug":"[]"}[0m 7.49ms] SNMP Check response code: 0 SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[7,"poll_mib"][0m 0.34ms] Attempting to initialize OS: iosxe OS initialized: LibreNMS\OS\Iosxe Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m] .*.*.0 = sonoma-edge.sonomaraceway.com .*.*.0 = .*.*.1707 .*.*.0 = Cisco IOS Software, ISR Software (X86_64_LINUX_IOSD-UNIVERSALK9-M), Version 15.4(3)S4, RELEASE SOFTWARE (fc3) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2015 by Cisco Systems, Inc. Compiled Mon 05-Oct-15 11:24 by mcpre >> Runtime for discovery module 'core': 0.0070 seconds with 1336 bytes >> SNMP: [2/0.04s] MySQL: [4/0.01s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Cisco IOS Software, ISR Software (X86_64_LINUX_IOSD-UNIVERSALK9-M), Version 15.4(3)S4, RELEASE SOFTWARE (fc3) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2015 by Cisco Systems, Inc. Compiled Mon 05-Oct-15 11:24 by mcpre SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.*.1707 | Cisco IOS Software, ISR Software (X86_64_LINUX_IOSD-UNIVERSALK9-M), Version 15.4(3)S4, RELEASE SOFTWARE (fc3) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2015 by Cisco Systems, Inc. Compiled Mon 05-Oct-15 11:24 by mcpre | .1.3.6.1.4.1.9.1.1707 | SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m] No Such Object available on this agent at this OID OS: Cisco IOS-XE (iosxe) >> Runtime for discovery module 'os': 0.0240 seconds with 1384 bytes >> SNMP: [3/0.02s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = GigabitEthernet0/0/0 ifDescr.2 = GigabitEthernet0/0/1 ifDescr.3 = GigabitEthernet0/0/2 ifDescr.4 = GigabitEthernet0/0/3 ifDescr.5 = GigabitEthernet0 ifDescr.6 = Null0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifName[0m] ifName.1 = Gi0/0/0 ifName.2 = Gi0/0/1 ifName.3 = Gi0/0/2 ifName.4 = Gi0/0/3 ifName.5 = Gi0 ifName.6 = Nu0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifAlias[0m] ifAlias.1 = VOM Internet ifAlias.2 = ifAlias.3 = ifAlias.4 = ifAlias.5 = ifAlias.6 = SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifType[0m] ifType.1 = ethernetCsmacd ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = ethernetCsmacd ifType.6 = other Array ( [1] => Array ( [ifDescr] => GigabitEthernet0/0/0 [ifName] => Gi0/0/0 [ifAlias] => VOM Internet [ifType] => ethernetCsmacd ) [2] => Array ( [ifDescr] => GigabitEthernet0/0/1 [ifName] => Gi0/0/1 [ifAlias] => [ifType] => ethernetCsmacd ) [3] => Array ( [ifDescr] => GigabitEthernet0/0/2 [ifName] => Gi0/0/2 [ifAlias] => [ifType] => ethernetCsmacd ) [4] => Array ( [ifDescr] => GigabitEthernet0/0/3 [ifName] => Gi0/0/3 [ifAlias] => [ifType] => ethernetCsmacd ) [5] => Array ( [ifDescr] => GigabitEthernet0 [ifName] => Gi0 [ifAlias] => [ifType] => ethernetCsmacd ) [6] => Array ( [ifDescr] => Null0 [ifName] => Nu0 [ifAlias] => [ifType] => other ) ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[7][0m 0.35ms] ...... >> Runtime for discovery module 'ports': 0.0340 seconds with 4256 bytes >> SNMP: [4/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '7' [0;33m[][0m 0.13ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ifStackStatus[0m] ifStackStatus.0.1 = active ifStackStatus.0.2 = active ifStackStatus.0.3 = active ifStackStatus.0.4 = active ifStackStatus.0.5 = active ifStackStatus.0.6 = active ifStackStatus.1.0 = active ifStackStatus.2.0 = active ifStackStatus.3.0 = active ifStackStatus.4.0 = active ifStackStatus.5.0 = active ifStackStatus.6.0 = active ............ >> Runtime for discovery module 'ports-stack': 0.0120 seconds with 1816 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalDescr.1 = Cisco ISR4451 Chassis entPhysicalDescr.2 = Power Supply Bay entPhysicalDescr.3 = 450W AC Power Supply for Cisco ISR4450, ISR4350 entPhysicalDescr.4 = Temp: Temp 1 entPhysicalDescr.5 = Temp: Temp 2 entPhysicalDescr.6 = Temp: Temp 3 entPhysicalDescr.7 = V: PEM Out entPhysicalDescr.8 = I: PEM In entPhysicalDescr.9 = I: PEM Out entPhysicalDescr.10 = P: In pwr entPhysicalDescr.11 = P: Out pwr entPhysicalDescr.12 = RPM: fan0 entPhysicalDescr.13 = Power Supply entPhysicalDescr.14 = Fan entPhysicalDescr.22 = Power Supply Bay entPhysicalDescr.42 = Fan Tray Bay entPhysicalDescr.43 = Cisco ISR4450, ISR4350 Fan Assembly entPhysicalDescr.44 = RPM: fan0 entPhysicalDescr.45 = RPM: fan1 entPhysicalDescr.46 = RPM: fan2 entPhysicalDescr.47 = RPM: fan3 entPhysicalDescr.48 = P: pwr entPhysicalDescr.54 = Fan entPhysicalDescr.55 = Fan entPhysicalDescr.56 = Fan entPhysicalDescr.57 = Fan entPhysicalDescr.62 = POE Bay entPhysicalDescr.82 = POE Bay entPhysicalDescr.102 = Internal POE Bay entPhysicalDescr.1000 = Cisco ISR4451 Built-In NIM controller entPhysicalDescr.1001 = Network Interface Module Subslot entPhysicalDescr.1002 = Network Interface Module Subslot entPhysicalDescr.1003 = Network Interface Module Subslot entPhysicalDescr.1004 = Packet Voice DSP Module Subslot entPhysicalDescr.1015 = Front Panel 4 ports Gigabitethernet Module entPhysicalDescr.1016 = ISR4451-X-4x1GE entPhysicalDescr.1017 = ISR4451-X-4x1GE entPhysicalDescr.1018 = ISR4451-X-4x1GE entPhysicalDescr.1019 = ISR4451-X-4x1GE entPhysicalDescr.1046 = subslot 0/0 transceiver container 0 entPhysicalDescr.1056 = subslot 0/0 transceiver container 1 entPhysicalDescr.1066 = subslot 0/0 transceiver container 2 entPhysicalDescr.1076 = subslot 0/0 transceiver container 3 entPhysicalDescr.3000 = Cisco ISR4451 Built-In SM controller entPhysicalDescr.3001 = Enhanced Service Module Slot entPhysicalDescr.5000 = Cisco ISR4451 Built-In SM controller entPhysicalDescr.5001 = Enhanced Service Module Slot entPhysicalDescr.7000 = Cisco ISR4451 Route Processor entPhysicalDescr.7001 = Temp: Inlet 1 entPhysicalDescr.7002 = Temp: Inlet 2 entPhysicalDescr.7003 = Temp: Outlet 1 entPhysicalDescr.7004 = Temp: Outlet 2 entPhysicalDescr.7005 = Temp: core-A entPhysicalDescr.7006 = Temp: core-B entPhysicalDescr.7007 = Temp: core-C entPhysicalDescr.7008 = V: 12v entPhysicalDescr.7009 = V: 5v entPhysicalDescr.7010 = V: 3.3v entPhysicalDescr.7011 = V: 3.0v entPhysicalDescr.7012 = V: 2.5v entPhysicalDescr.7013 = V: 1.05v entPhysicalDescr.7014 = V: 1.8v entPhysicalDescr.7015 = V: 1.2v entPhysicalDescr.7016 = V: Vcore-C entPhysicalDescr.7017 = V: 1.1v entPhysicalDescr.7018 = V: 1.0v entPhysicalDescr.7019 = V: 1.8v-A entPhysicalDescr.7020 = V: 1.5v-A entPhysicalDescr.7021 = V: 1.5v-C1 entPhysicalDescr.7022 = V: 1.5v-B entPhysicalDescr.7023 = V: Vcore-A entPhysicalDescr.7024 = V: 1.5v-C2 entPhysicalDescr.7025 = V: Vcore-B1 entPhysicalDescr.7026 = V: Vcore-B2 entPhysicalDescr.7027 = V: 0.75v-B entPhysicalDescr.7028 = V: 0.75v-C entPhysicalDescr.7029 = I: 12v entPhysicalDescr.7030 = P: pwr entPhysicalDescr.7035 = CPU 0 of module R0 entPhysicalDescr.7036 = USB Port entPhysicalDescr.7038 = USB Port entPhysicalDescr.7040 = Network Management Ethernet entPhysicalDescr.9000 = Cisco ISR4451 Forwarding Processor entPhysicalDescr.9001 = QFP 0 of module F0 entPhysicalVendorType.1 = cevChassis.1248 entPhysicalVendorType.2 = cevContainer.269 entPhysicalVendorType.3 = cevPowerSupply.346 entPhysicalVendorType.4 = cevSensorModuleDeviceTemp entPhysicalVendorType.5 = cevSensorModuleDeviceTemp entPhysicalVendorType.6 = cevSensorModuleDeviceTemp entPhysicalVendorType.7 = cevSensorModuleDeviceVoltage entPhysicalVendorType.8 = cevSensorModuleDeviceCurrent entPhysicalVendorType.9 = cevSensorModuleDeviceCurrent entPhysicalVendorType.10 = cevSensor.132 entPhysicalVendorType.11 = cevSensor.132 entPhysicalVendorType.12 = cevSensor.133 entPhysicalVendorType.13 = cevPowerSupply.364 entPhysicalVendorType.14 = cevFan.195 entPhysicalVendorType.22 = cevContainer.269 entPhysicalVendorType.42 = cevContainer.270 entPhysicalVendorType.43 = cevFan.185 entPhysicalVendorType.44 = cevSensor.133 entPhysicalVendorType.45 = cevSensor.133 entPhysicalVendorType.46 = cevSensor.133 entPhysicalVendorType.47 = cevSensor.133 entPhysicalVendorType.48 = cevSensor.132 entPhysicalVendorType.54 = cevFan.195 entPhysicalVendorType.55 = cevFan.195 entPhysicalVendorType.56 = cevFan.195 entPhysicalVendorType.57 = cevFan.195 entPhysicalVendorType.62 = cevContainer.271 entPhysicalVendorType.82 = cevContainer.271 entPhysicalVendorType.102 = cevContainer.272 entPhysicalVendorType.1000 = cevModule.92.14 entPhysicalVendorType.1001 = cevContainer.323 entPhysicalVendorType.1002 = cevContainer.323 entPhysicalVendorType.1003 = cevContainer.323 entPhysicalVendorType.1004 = cevContainer.324 entPhysicalVendorType.1015 = cevModule.92.21 entPhysicalVendorType.1016 = cevPortGe entPhysicalVendorType.1017 = cevPortGe entPhysicalVendorType.1018 = cevPortGe entPhysicalVendorType.1019 = cevPortGe entPhysicalVendorType.1046 = cevContainerSFP entPhysicalVendorType.1056 = cevContainerSFP entPhysicalVendorType.1066 = cevContainerSFP entPhysicalVendorType.1076 = cevContainerSFP entPhysicalVendorType.3000 = cevModule.92.19 entPhysicalVendorType.3001 = cevContainer.268 entPhysicalVendorType.5000 = cevModule.92.19 entPhysicalVendorType.5001 = cevContainer.268 entPhysicalVendorType.7000 = cevModule.92.3 entPhysicalVendorType.7001 = cevSensorModuleDeviceTemp entPhysicalVendorType.7002 = cevSensorModuleDeviceTemp entPhysicalVendorType.7003 = cevSensorModuleDeviceTemp entPhysicalVendorType.7004 = cevSensorModuleDeviceTemp entPhysicalVendorType.7005 = cevSensorModuleDeviceTemp entPhysicalVendorType.7006 = cevSensorModuleDeviceTemp entPhysicalVendorType.7007 = cevSensorModuleDeviceTemp entPhysicalVendorType.7008 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7009 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7010 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7011 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7012 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7013 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7014 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7015 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7016 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7017 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7018 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7019 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7020 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7021 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7022 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7023 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7024 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7025 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7026 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7027 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7028 = cevSensorModuleDeviceVoltage entPhysicalVendorType.7029 = cevSensorModuleDeviceCurrent entPhysicalVendorType.7030 = cevSensor.132 entPhysicalVendorType.7035 = cevModuleCpuType entPhysicalVendorType.7036 = cevContainer.333 entPhysicalVendorType.7038 = cevContainer.333 entPhysicalVendorType.7040 = cevPortGe entPhysicalVendorType.9000 = cevModule.92.8 entPhysicalVendorType.9001 = cevModuleCpuType entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 2 entPhysicalContainedIn.4 = 3 entPhysicalContainedIn.5 = 3 entPhysicalContainedIn.6 = 3 entPhysicalContainedIn.7 = 3 entPhysicalContainedIn.8 = 3 entPhysicalContainedIn.9 = 3 entPhysicalContainedIn.10 = 3 entPhysicalContainedIn.11 = 3 entPhysicalContainedIn.12 = 3 entPhysicalContainedIn.13 = 3 entPhysicalContainedIn.14 = 3 entPhysicalContainedIn.22 = 1 entPhysicalContainedIn.42 = 1 entPhysicalContainedIn.43 = 42 entPhysicalContainedIn.44 = 43 entPhysicalContainedIn.45 = 43 entPhysicalContainedIn.46 = 43 entPhysicalContainedIn.47 = 43 entPhysicalContainedIn.48 = 43 entPhysicalContainedIn.54 = 43 entPhysicalContainedIn.55 = 43 entPhysicalContainedIn.56 = 43 entPhysicalContainedIn.57 = 43 entPhysicalContainedIn.62 = 1 entPhysicalContainedIn.82 = 1 entPhysicalContainedIn.102 = 1 entPhysicalContainedIn.1000 = 1 entPhysicalContainedIn.1001 = 1000 entPhysicalContainedIn.1002 = 1000 entPhysicalContainedIn.1003 = 1000 entPhysicalContainedIn.1004 = 1000 entPhysicalContainedIn.1015 = 1000 entPhysicalContainedIn.1016 = 1015 entPhysicalContainedIn.1017 = 1015 entPhysicalContainedIn.1018 = 1015 entPhysicalContainedIn.1019 = 1015 entPhysicalContainedIn.1046 = 1015 entPhysicalContainedIn.1056 = 1015 entPhysicalContainedIn.1066 = 1015 entPhysicalContainedIn.1076 = 1015 entPhysicalContainedIn.3000 = 1 entPhysicalContainedIn.3001 = 3000 entPhysicalContainedIn.5000 = 1 entPhysicalContainedIn.5001 = 5000 entPhysicalContainedIn.7000 = 1 entPhysicalContainedIn.7001 = 7000 entPhysicalContainedIn.7002 = 7000 entPhysicalContainedIn.7003 = 7000 entPhysicalContainedIn.7004 = 7000 entPhysicalContainedIn.7005 = 7000 entPhysicalContainedIn.7006 = 7000 entPhysicalContainedIn.7007 = 7000 entPhysicalContainedIn.7008 = 7000 entPhysicalContainedIn.7009 = 7000 entPhysicalContainedIn.7010 = 7000 entPhysicalContainedIn.7011 = 7000 entPhysicalContainedIn.7012 = 7000 entPhysicalContainedIn.7013 = 7000 entPhysicalContainedIn.7014 = 7000 entPhysicalContainedIn.7015 = 7000 entPhysicalContainedIn.7016 = 7000 entPhysicalContainedIn.7017 = 7000 entPhysicalContainedIn.7018 = 7000 entPhysicalContainedIn.7019 = 7000 entPhysicalContainedIn.7020 = 7000 entPhysicalContainedIn.7021 = 7000 entPhysicalContainedIn.7022 = 7000 entPhysicalContainedIn.7023 = 7000 entPhysicalContainedIn.7024 = 7000 entPhysicalContainedIn.7025 = 7000 entPhysicalContainedIn.7026 = 7000 entPhysicalContainedIn.7027 = 7000 entPhysicalContainedIn.7028 = 7000 entPhysicalContainedIn.7029 = 7000 entPhysicalContainedIn.7030 = 7000 entPhysicalContainedIn.7035 = 7000 entPhysicalContainedIn.7036 = 7000 entPhysicalContainedIn.7038 = 7000 entPhysicalContainedIn.7040 = 7000 entPhysicalContainedIn.9000 = 1 entPhysicalContainedIn.9001 = 9000 entPhysicalClass.1 = chassis entPhysicalClass.2 = container entPhysicalClass.3 = powerSupply entPhysicalClass.4 = sensor entPhysicalClass.5 = sensor entPhysicalClass.6 = sensor entPhysicalClass.7 = sensor entPhysicalClass.8 = sensor entPhysicalClass.9 = sensor entPhysicalClass.10 = sensor entPhysicalClass.11 = sensor entPhysicalClass.12 = sensor entPhysicalClass.13 = powerSupply entPhysicalClass.14 = fan entPhysicalClass.22 = container entPhysicalClass.42 = container entPhysicalClass.43 = fan entPhysicalClass.44 = sensor entPhysicalClass.45 = sensor entPhysicalClass.46 = sensor entPhysicalClass.47 = sensor entPhysicalClass.48 = sensor entPhysicalClass.54 = fan entPhysicalClass.55 = fan entPhysicalClass.56 = fan entPhysicalClass.57 = fan entPhysicalClass.62 = container entPhysicalClass.82 = container entPhysicalClass.102 = container entPhysicalClass.1000 = module entPhysicalClass.1001 = container entPhysicalClass.1002 = container entPhysicalClass.1003 = container entPhysicalClass.1004 = container entPhysicalClass.1015 = module entPhysicalClass.1016 = port entPhysicalClass.1017 = port entPhysicalClass.1018 = port entPhysicalClass.1019 = port entPhysicalClass.1046 = container entPhysicalClass.1056 = container entPhysicalClass.1066 = container entPhysicalClass.1076 = container entPhysicalClass.3000 = module entPhysicalClass.3001 = container entPhysicalClass.5000 = module entPhysicalClass.5001 = container entPhysicalClass.7000 = module entPhysicalClass.7001 = sensor entPhysicalClass.7002 = sensor entPhysicalClass.7003 = sensor entPhysicalClass.7004 = sensor entPhysicalClass.7005 = sensor entPhysicalClass.7006 = sensor entPhysicalClass.7007 = sensor entPhysicalClass.7008 = sensor entPhysicalClass.7009 = sensor entPhysicalClass.7010 = sensor entPhysicalClass.7011 = sensor entPhysicalClass.7012 = sensor entPhysicalClass.7013 = sensor entPhysicalClass.7014 = sensor entPhysicalClass.7015 = sensor entPhysicalClass.7016 = sensor entPhysicalClass.7017 = sensor entPhysicalClass.7018 = sensor entPhysicalClass.7019 = sensor entPhysicalClass.7020 = sensor entPhysicalClass.7021 = sensor entPhysicalClass.7022 = sensor entPhysicalClass.7023 = sensor entPhysicalClass.7024 = sensor entPhysicalClass.7025 = sensor entPhysicalClass.7026 = sensor entPhysicalClass.7027 = sensor entPhysicalClass.7028 = sensor entPhysicalClass.7029 = sensor entPhysicalClass.7030 = sensor entPhysicalClass.7035 = cpu entPhysicalClass.7036 = container entPhysicalClass.7038 = container entPhysicalClass.7040 = port entPhysicalClass.9000 = module entPhysicalClass.9001 = cpu entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 9 entPhysicalParentRelPos.3 = 0 entPhysicalParentRelPos.4 = 0 entPhysicalParentRelPos.5 = 1 entPhysicalParentRelPos.6 = 2 entPhysicalParentRelPos.7 = 3 entPhysicalParentRelPos.8 = 4 entPhysicalParentRelPos.9 = 5 entPhysicalParentRelPos.10 = 6 entPhysicalParentRelPos.11 = 7 entPhysicalParentRelPos.12 = 8 entPhysicalParentRelPos.13 = 0 entPhysicalParentRelPos.14 = 0 entPhysicalParentRelPos.22 = 10 entPhysicalParentRelPos.42 = 11 entPhysicalParentRelPos.43 = 0 entPhysicalParentRelPos.44 = 0 entPhysicalParentRelPos.45 = 1 entPhysicalParentRelPos.46 = 2 entPhysicalParentRelPos.47 = 3 entPhysicalParentRelPos.48 = 4 entPhysicalParentRelPos.54 = 0 entPhysicalParentRelPos.55 = 1 entPhysicalParentRelPos.56 = 2 entPhysicalParentRelPos.57 = 3 entPhysicalParentRelPos.62 = 12 entPhysicalParentRelPos.82 = 13 entPhysicalParentRelPos.102 = 14 entPhysicalParentRelPos.1000 = 0 entPhysicalParentRelPos.1001 = 1 entPhysicalParentRelPos.1002 = 2 entPhysicalParentRelPos.1003 = 3 entPhysicalParentRelPos.1004 = 4 entPhysicalParentRelPos.1015 = 0 entPhysicalParentRelPos.1016 = 0 entPhysicalParentRelPos.1017 = 1 entPhysicalParentRelPos.1018 = 2 entPhysicalParentRelPos.1019 = 3 entPhysicalParentRelPos.1046 = 0 entPhysicalParentRelPos.1056 = 1 entPhysicalParentRelPos.1066 = 2 entPhysicalParentRelPos.1076 = 3 entPhysicalParentRelPos.3000 = 1 entPhysicalParentRelPos.3001 = 0 entPhysicalParentRelPos.5000 = 2 entPhysicalParentRelPos.5001 = 0 entPhysicalParentRelPos.7000 = 6 entPhysicalParentRelPos.7001 = 0 entPhysicalParentRelPos.7002 = 1 entPhysicalParentRelPos.7003 = 2 entPhysicalParentRelPos.7004 = 3 entPhysicalParentRelPos.7005 = 4 entPhysicalParentRelPos.7006 = 5 entPhysicalParentRelPos.7007 = 6 entPhysicalParentRelPos.7008 = 7 entPhysicalParentRelPos.7009 = 8 entPhysicalParentRelPos.7010 = 9 entPhysicalParentRelPos.7011 = 10 entPhysicalParentRelPos.7012 = 11 entPhysicalParentRelPos.7013 = 12 entPhysicalParentRelPos.7014 = 13 entPhysicalParentRelPos.7015 = 14 entPhysicalParentRelPos.7016 = 15 entPhysicalParentRelPos.7017 = 16 entPhysicalParentRelPos.7018 = 17 entPhysicalParentRelPos.7019 = 18 entPhysicalParentRelPos.7020 = 19 entPhysicalParentRelPos.7021 = 20 entPhysicalParentRelPos.7022 = 21 entPhysicalParentRelPos.7023 = 22 entPhysicalParentRelPos.7024 = 23 entPhysicalParentRelPos.7025 = 24 entPhysicalParentRelPos.7026 = 25 entPhysicalParentRelPos.7027 = 26 entPhysicalParentRelPos.7028 = 27 entPhysicalParentRelPos.7029 = 28 entPhysicalParentRelPos.7030 = 29 entPhysicalParentRelPos.7035 = 0 entPhysicalParentRelPos.7036 = 0 entPhysicalParentRelPos.7038 = 1 entPhysicalParentRelPos.7040 = 2 entPhysicalParentRelPos.9000 = 8 entPhysicalParentRelPos.9001 = 0 entPhysicalName.1 = Chassis entPhysicalName.2 = Power Supply Bay 0 entPhysicalName.3 = Power Supply Module 0 entPhysicalName.4 = Temp: Temp 1 P0/0 entPhysicalName.5 = Temp: Temp 2 P0/1 entPhysicalName.6 = Temp: Temp 3 P0/2 entPhysicalName.7 = V: PEM Out P0/3 entPhysicalName.8 = I: PEM In P0/4 entPhysicalName.9 = I: PEM Out P0/5 entPhysicalName.10 = P: In pwr P0/6 entPhysicalName.11 = P: Out pwr P0/7 entPhysicalName.12 = RPM: fan0 P0/8 entPhysicalName.13 = Power Supply 0 entPhysicalName.14 = Fan 0/0 entPhysicalName.22 = Power Supply Bay 1 entPhysicalName.42 = Fan Tray Bay 0 entPhysicalName.43 = Fan Tray entPhysicalName.44 = RPM: fan0 P2/0 entPhysicalName.45 = RPM: fan1 P2/1 entPhysicalName.46 = RPM: fan2 P2/2 entPhysicalName.47 = RPM: fan3 P2/3 entPhysicalName.48 = P: pwr P2/4 entPhysicalName.54 = Fan 2/0 entPhysicalName.55 = Fan 2/1 entPhysicalName.56 = Fan 2/2 entPhysicalName.57 = Fan 2/3 entPhysicalName.62 = POE Bay 0 entPhysicalName.82 = POE Bay 1 entPhysicalName.102 = Internal POE Bay 0 entPhysicalName.1000 = module 0 entPhysicalName.1001 = subslot 0/1 entPhysicalName.1002 = subslot 0/2 entPhysicalName.1003 = subslot 0/3 entPhysicalName.1004 = subslot 0/4 entPhysicalName.1015 = NIM subslot 0/0 entPhysicalName.1016 = GigabitEthernet0/0/0 entPhysicalName.1017 = GigabitEthernet0/0/1 entPhysicalName.1018 = GigabitEthernet0/0/2 entPhysicalName.1019 = GigabitEthernet0/0/3 entPhysicalName.1046 = subslot 0/0 transceiver container 0 entPhysicalName.1056 = subslot 0/0 transceiver container 1 entPhysicalName.1066 = subslot 0/0 transceiver container 2 entPhysicalName.1076 = subslot 0/0 transceiver container 3 entPhysicalName.3000 = module 1 entPhysicalName.3001 = slot 1 entPhysicalName.5000 = module 2 entPhysicalName.5001 = slot 2 entPhysicalName.7000 = module R0 entPhysicalName.7001 = Temp: Inlet 1 R0/0 entPhysicalName.7002 = Temp: Inlet 2 R0/1 entPhysicalName.7003 = Temp: Outlet 1 R0/2 entPhysicalName.7004 = Temp: Outlet 2 R0/3 entPhysicalName.7005 = Temp: core-A R0/4 entPhysicalName.7006 = Temp: core-B R0/5 entPhysicalName.7007 = Temp: core-C R0/6 entPhysicalName.7008 = V: 12v R0/7 entPhysicalName.7009 = V: 5v R0/8 entPhysicalName.7010 = V: 3.3v R0/9 entPhysicalName.7011 = V: 3.0v R0/10 entPhysicalName.7012 = V: 2.5v R0/11 entPhysicalName.7013 = V: 1.05v R0/12 entPhysicalName.7014 = V: 1.8v R0/13 entPhysicalName.7015 = V: 1.2v R0/14 entPhysicalName.7016 = V: Vcore-C R0/15 entPhysicalName.7017 = V: 1.1v R0/16 entPhysicalName.7018 = V: 1.0v R0/17 entPhysicalName.7019 = V: 1.8v-A R0/18 entPhysicalName.7020 = V: 1.5v-A R0/19 entPhysicalName.7021 = V: 1.5v-C1 R0/20 entPhysicalName.7022 = V: 1.5v-B R0/21 entPhysicalName.7023 = V: Vcore-A R0/22 entPhysicalName.7024 = V: 1.5v-C2 R0/23 entPhysicalName.7025 = V: Vcore-B1 R0/24 entPhysicalName.7026 = V: Vcore-B2 R0/25 entPhysicalName.7027 = V: 0.75v-B R0/26 entPhysicalName.7028 = V: 0.75v-C R0/27 entPhysicalName.7029 = I: 12v R0/28 entPhysicalName.7030 = P: pwr R0/29 entPhysicalName.7035 = cpu R0/0 entPhysicalName.7036 = usb R0/0 entPhysicalName.7038 = usb R0/1 entPhysicalName.7040 = NME R0 entPhysicalName.9000 = module F0 entPhysicalName.9001 = qfp F0/0 entPhysicalHardwareRev.1 = V06 entPhysicalHardwareRev.2 = entPhysicalHardwareRev.3 = V02 entPhysicalHardwareRev.4 = entPhysicalHardwareRev.5 = entPhysicalHardwareRev.6 = entPhysicalHardwareRev.7 = entPhysicalHardwareRev.8 = entPhysicalHardwareRev.9 = entPhysicalHardwareRev.10 = entPhysicalHardwareRev.11 = entPhysicalHardwareRev.12 = entPhysicalHardwareRev.13 = entPhysicalHardwareRev.14 = entPhysicalHardwareRev.22 = entPhysicalHardwareRev.42 = entPhysicalHardwareRev.43 = entPhysicalHardwareRev.44 = entPhysicalHardwareRev.45 = entPhysicalHardwareRev.46 = entPhysicalHardwareRev.47 = entPhysicalHardwareRev.48 = entPhysicalHardwareRev.54 = entPhysicalHardwareRev.55 = entPhysicalHardwareRev.56 = entPhysicalHardwareRev.57 = entPhysicalHardwareRev.62 = entPhysicalHardwareRev.82 = entPhysicalHardwareRev.102 = entPhysicalHardwareRev.1000 = entPhysicalHardwareRev.1001 = entPhysicalHardwareRev.1002 = entPhysicalHardwareRev.1003 = entPhysicalHardwareRev.1004 = entPhysicalHardwareRev.1015 = V01 entPhysicalHardwareRev.1016 = entPhysicalHardwareRev.1017 = entPhysicalHardwareRev.1018 = entPhysicalHardwareRev.1019 = entPhysicalHardwareRev.1046 = entPhysicalHardwareRev.1056 = entPhysicalHardwareRev.1066 = entPhysicalHardwareRev.1076 = entPhysicalHardwareRev.3000 = entPhysicalHardwareRev.3001 = entPhysicalHardwareRev.5000 = entPhysicalHardwareRev.5001 = entPhysicalHardwareRev.7000 = V06 entPhysicalHardwareRev.7001 = entPhysicalHardwareRev.7002 = entPhysicalHardwareRev.7003 = entPhysicalHardwareRev.7004 = entPhysicalHardwareRev.7005 = entPhysicalHardwareRev.7006 = entPhysicalHardwareRev.7007 = entPhysicalHardwareRev.7008 = entPhysicalHardwareRev.7009 = entPhysicalHardwareRev.7010 = entPhysicalHardwareRev.7011 = entPhysicalHardwareRev.7012 = entPhysicalHardwareRev.7013 = entPhysicalHardwareRev.7014 = entPhysicalHardwareRev.7015 = entPhysicalHardwareRev.7016 = entPhysicalHardwareRev.7017 = entPhysicalHardwareRev.7018 = entPhysicalHardwareRev.7019 = entPhysicalHardwareRev.7020 = entPhysicalHardwareRev.7021 = entPhysicalHardwareRev.7022 = entPhysicalHardwareRev.7023 = entPhysicalHardwareRev.7024 = entPhysicalHardwareRev.7025 = entPhysicalHardwareRev.7026 = entPhysicalHardwareRev.7027 = entPhysicalHardwareRev.7028 = entPhysicalHardwareRev.7029 = entPhysicalHardwareRev.7030 = entPhysicalHardwareRev.7035 = entPhysicalHardwareRev.7036 = entPhysicalHardwareRev.7038 = entPhysicalHardwareRev.7040 = entPhysicalHardwareRev.9000 = entPhysicalHardwareRev.9001 = entPhysicalFirmwareRev.1 = entPhysicalFirmwareRev.2 = entPhysicalFirmwareRev.3 = entPhysicalFirmwareRev.4 = entPhysicalFirmwareRev.5 = entPhysicalFirmwareRev.6 = entPhysicalFirmwareRev.7 = entPhysicalFirmwareRev.8 = entPhysicalFirmwareRev.9 = entPhysicalFirmwareRev.10 = entPhysicalFirmwareRev.11 = entPhysicalFirmwareRev.12 = entPhysicalFirmwareRev.13 = entPhysicalFirmwareRev.14 = entPhysicalFirmwareRev.22 = entPhysicalFirmwareRev.42 = entPhysicalFirmwareRev.43 = entPhysicalFirmwareRev.44 = entPhysicalFirmwareRev.45 = entPhysicalFirmwareRev.46 = entPhysicalFirmwareRev.47 = entPhysicalFirmwareRev.48 = entPhysicalFirmwareRev.54 = entPhysicalFirmwareRev.55 = entPhysicalFirmwareRev.56 = entPhysicalFirmwareRev.57 = entPhysicalFirmwareRev.62 = entPhysicalFirmwareRev.82 = entPhysicalFirmwareRev.102 = entPhysicalFirmwareRev.1000 = 15.4(3r)S entPhysicalFirmwareRev.1001 = entPhysicalFirmwareRev.1002 = entPhysicalFirmwareRev.1003 = entPhysicalFirmwareRev.1004 = entPhysicalFirmwareRev.1015 = entPhysicalFirmwareRev.1016 = entPhysicalFirmwareRev.1017 = entPhysicalFirmwareRev.1018 = entPhysicalFirmwareRev.1019 = entPhysicalFirmwareRev.1046 = entPhysicalFirmwareRev.1056 = entPhysicalFirmwareRev.1066 = entPhysicalFirmwareRev.1076 = entPhysicalFirmwareRev.3000 = 15.4(3r)S entPhysicalFirmwareRev.3001 = entPhysicalFirmwareRev.5000 = 15.4(3r)S entPhysicalFirmwareRev.5001 = entPhysicalFirmwareRev.7000 = 15.4(3r)S entPhysicalFirmwareRev.7001 = entPhysicalFirmwareRev.7002 = entPhysicalFirmwareRev.7003 = entPhysicalFirmwareRev.7004 = entPhysicalFirmwareRev.7005 = entPhysicalFirmwareRev.7006 = entPhysicalFirmwareRev.7007 = entPhysicalFirmwareRev.7008 = entPhysicalFirmwareRev.7009 = entPhysicalFirmwareRev.7010 = entPhysicalFirmwareRev.7011 = entPhysicalFirmwareRev.7012 = entPhysicalFirmwareRev.7013 = entPhysicalFirmwareRev.7014 = entPhysicalFirmwareRev.7015 = entPhysicalFirmwareRev.7016 = entPhysicalFirmwareRev.7017 = entPhysicalFirmwareRev.7018 = entPhysicalFirmwareRev.7019 = entPhysicalFirmwareRev.7020 = entPhysicalFirmwareRev.7021 = entPhysicalFirmwareRev.7022 = entPhysicalFirmwareRev.7023 = entPhysicalFirmwareRev.7024 = entPhysicalFirmwareRev.7025 = entPhysicalFirmwareRev.7026 = entPhysicalFirmwareRev.7027 = entPhysicalFirmwareRev.7028 = entPhysicalFirmwareRev.7029 = entPhysicalFirmwareRev.7030 = entPhysicalFirmwareRev.7035 = entPhysicalFirmwareRev.7036 = entPhysicalFirmwareRev.7038 = entPhysicalFirmwareRev.7040 = entPhysicalFirmwareRev.9000 = 15.4(3r)S entPhysicalFirmwareRev.9001 = entPhysicalSoftwareRev.1 = entPhysicalSoftwareRev.2 = entPhysicalSoftwareRev.3 = entPhysicalSoftwareRev.4 = entPhysicalSoftwareRev.5 = entPhysicalSoftwareRev.6 = entPhysicalSoftwareRev.7 = entPhysicalSoftwareRev.8 = entPhysicalSoftwareRev.9 = entPhysicalSoftwareRev.10 = entPhysicalSoftwareRev.11 = entPhysicalSoftwareRev.12 = entPhysicalSoftwareRev.13 = entPhysicalSoftwareRev.14 = entPhysicalSoftwareRev.22 = entPhysicalSoftwareRev.42 = entPhysicalSoftwareRev.43 = entPhysicalSoftwareRev.44 = entPhysicalSoftwareRev.45 = entPhysicalSoftwareRev.46 = entPhysicalSoftwareRev.47 = entPhysicalSoftwareRev.48 = entPhysicalSoftwareRev.54 = entPhysicalSoftwareRev.55 = entPhysicalSoftwareRev.56 = entPhysicalSoftwareRev.57 = entPhysicalSoftwareRev.62 = entPhysicalSoftwareRev.82 = entPhysicalSoftwareRev.102 = entPhysicalSoftwareRev.1000 = 03.13.04.S.154-3.S4-ext entPhysicalSoftwareRev.1001 = entPhysicalSoftwareRev.1002 = entPhysicalSoftwareRev.1003 = entPhysicalSoftwareRev.1004 = entPhysicalSoftwareRev.1015 = entPhysicalSoftwareRev.1016 = entPhysicalSoftwareRev.1017 = entPhysicalSoftwareRev.1018 = entPhysicalSoftwareRev.1019 = entPhysicalSoftwareRev.1046 = entPhysicalSoftwareRev.1056 = entPhysicalSoftwareRev.1066 = entPhysicalSoftwareRev.1076 = entPhysicalSoftwareRev.3000 = 03.13.04.S.154-3.S4-ext entPhysicalSoftwareRev.3001 = entPhysicalSoftwareRev.5000 = 03.13.04.S.154-3.S4-ext entPhysicalSoftwareRev.5001 = entPhysicalSoftwareRev.7000 = 03.13.04.S.154-3.S4-ext entPhysicalSoftwareRev.7001 = entPhysicalSoftwareRev.7002 = entPhysicalSoftwareRev.7003 = entPhysicalSoftwareRev.7004 = entPhysicalSoftwareRev.7005 = entPhysicalSoftwareRev.7006 = entPhysicalSoftwareRev.7007 = entPhysicalSoftwareRev.7008 = entPhysicalSoftwareRev.7009 = entPhysicalSoftwareRev.7010 = entPhysicalSoftwareRev.7011 = entPhysicalSoftwareRev.7012 = entPhysicalSoftwareRev.7013 = entPhysicalSoftwareRev.7014 = entPhysicalSoftwareRev.7015 = entPhysicalSoftwareRev.7016 = entPhysicalSoftwareRev.7017 = entPhysicalSoftwareRev.7018 = entPhysicalSoftwareRev.7019 = entPhysicalSoftwareRev.7020 = entPhysicalSoftwareRev.7021 = entPhysicalSoftwareRev.7022 = entPhysicalSoftwareRev.7023 = entPhysicalSoftwareRev.7024 = entPhysicalSoftwareRev.7025 = entPhysicalSoftwareRev.7026 = entPhysicalSoftwareRev.7027 = entPhysicalSoftwareRev.7028 = entPhysicalSoftwareRev.7029 = entPhysicalSoftwareRev.7030 = entPhysicalSoftwareRev.7035 = entPhysicalSoftwareRev.7036 = entPhysicalSoftwareRev.7038 = entPhysicalSoftwareRev.7040 = entPhysicalSoftwareRev.9000 = 03.13.04.S.154-3.S4-ext entPhysicalSoftwareRev.9001 = entPhysicalSerialNum.1 = FJC2006D0AE entPhysicalSerialNum.2 = entPhysicalSerialNum.3 = DCA1949X11S entPhysicalSerialNum.4 = entPhysicalSerialNum.5 = entPhysicalSerialNum.6 = entPhysicalSerialNum.7 = entPhysicalSerialNum.8 = entPhysicalSerialNum.9 = entPhysicalSerialNum.10 = entPhysicalSerialNum.11 = entPhysicalSerialNum.12 = entPhysicalSerialNum.13 = entPhysicalSerialNum.14 = entPhysicalSerialNum.22 = entPhysicalSerialNum.42 = entPhysicalSerialNum.43 = entPhysicalSerialNum.44 = entPhysicalSerialNum.45 = entPhysicalSerialNum.46 = entPhysicalSerialNum.47 = entPhysicalSerialNum.48 = entPhysicalSerialNum.54 = entPhysicalSerialNum.55 = entPhysicalSerialNum.56 = entPhysicalSerialNum.57 = entPhysicalSerialNum.62 = entPhysicalSerialNum.82 = entPhysicalSerialNum.102 = entPhysicalSerialNum.1000 = entPhysicalSerialNum.1001 = entPhysicalSerialNum.1002 = entPhysicalSerialNum.1003 = entPhysicalSerialNum.1004 = entPhysicalSerialNum.1015 = JAB092709EL entPhysicalSerialNum.1016 = entPhysicalSerialNum.1017 = entPhysicalSerialNum.1018 = entPhysicalSerialNum.1019 = entPhysicalSerialNum.1046 = entPhysicalSerialNum.1056 = entPhysicalSerialNum.1066 = entPhysicalSerialNum.1076 = entPhysicalSerialNum.3000 = entPhysicalSerialNum.3001 = entPhysicalSerialNum.5000 = entPhysicalSerialNum.5001 = entPhysicalSerialNum.7000 = FOC19515Y3Z entPhysicalSerialNum.7001 = entPhysicalSerialNum.7002 = entPhysicalSerialNum.7003 = entPhysicalSerialNum.7004 = entPhysicalSerialNum.7005 = entPhysicalSerialNum.7006 = entPhysicalSerialNum.7007 = entPhysicalSerialNum.7008 = entPhysicalSerialNum.7009 = entPhysicalSerialNum.7010 = entPhysicalSerialNum.7011 = entPhysicalSerialNum.7012 = entPhysicalSerialNum.7013 = entPhysicalSerialNum.7014 = entPhysicalSerialNum.7015 = entPhysicalSerialNum.7016 = entPhysicalSerialNum.7017 = entPhysicalSerialNum.7018 = entPhysicalSerialNum.7019 = entPhysicalSerialNum.7020 = entPhysicalSerialNum.7021 = entPhysicalSerialNum.7022 = entPhysicalSerialNum.7023 = entPhysicalSerialNum.7024 = entPhysicalSerialNum.7025 = entPhysicalSerialNum.7026 = entPhysicalSerialNum.7027 = entPhysicalSerialNum.7028 = entPhysicalSerialNum.7029 = entPhysicalSerialNum.7030 = entPhysicalSerialNum.7035 = entPhysicalSerialNum.7036 = entPhysicalSerialNum.7038 = entPhysicalSerialNum.7040 = entPhysicalSerialNum.9000 = entPhysicalSerialNum.9001 = entPhysicalMfgName.1 = Cisco Systems Inc entPhysicalMfgName.2 = entPhysicalMfgName.3 = Cisco Systems Inc entPhysicalMfgName.4 = entPhysicalMfgName.5 = entPhysicalMfgName.6 = entPhysicalMfgName.7 = entPhysicalMfgName.8 = entPhysicalMfgName.9 = entPhysicalMfgName.10 = entPhysicalMfgName.11 = entPhysicalMfgName.12 = entPhysicalMfgName.13 = entPhysicalMfgName.14 = entPhysicalMfgName.22 = entPhysicalMfgName.42 = entPhysicalMfgName.43 = Cisco Systems Inc entPhysicalMfgName.44 = entPhysicalMfgName.45 = entPhysicalMfgName.46 = entPhysicalMfgName.47 = entPhysicalMfgName.48 = entPhysicalMfgName.54 = entPhysicalMfgName.55 = entPhysicalMfgName.56 = entPhysicalMfgName.57 = entPhysicalMfgName.62 = entPhysicalMfgName.82 = entPhysicalMfgName.102 = entPhysicalMfgName.1000 = Cisco Systems Inc entPhysicalMfgName.1001 = entPhysicalMfgName.1002 = entPhysicalMfgName.1003 = entPhysicalMfgName.1004 = entPhysicalMfgName.1015 = Cisco Systems Inc entPhysicalMfgName.1016 = entPhysicalMfgName.1017 = entPhysicalMfgName.1018 = entPhysicalMfgName.1019 = entPhysicalMfgName.1046 = entPhysicalMfgName.1056 = entPhysicalMfgName.1066 = entPhysicalMfgName.1076 = entPhysicalMfgName.3000 = Cisco Systems Inc entPhysicalMfgName.3001 = entPhysicalMfgName.5000 = Cisco Systems Inc entPhysicalMfgName.5001 = entPhysicalMfgName.7000 = Cisco Systems Inc entPhysicalMfgName.7001 = entPhysicalMfgName.7002 = entPhysicalMfgName.7003 = entPhysicalMfgName.7004 = entPhysicalMfgName.7005 = entPhysicalMfgName.7006 = entPhysicalMfgName.7007 = entPhysicalMfgName.7008 = entPhysicalMfgName.7009 = entPhysicalMfgName.7010 = entPhysicalMfgName.7011 = entPhysicalMfgName.7012 = entPhysicalMfgName.7013 = entPhysicalMfgName.7014 = entPhysicalMfgName.7015 = entPhysicalMfgName.7016 = entPhysicalMfgName.7017 = entPhysicalMfgName.7018 = entPhysicalMfgName.7019 = entPhysicalMfgName.7020 = entPhysicalMfgName.7021 = entPhysicalMfgName.7022 = entPhysicalMfgName.7023 = entPhysicalMfgName.7024 = entPhysicalMfgName.7025 = entPhysicalMfgName.7026 = entPhysicalMfgName.7027 = entPhysicalMfgName.7028 = entPhysicalMfgName.7029 = entPhysicalMfgName.7030 = entPhysicalMfgName.7035 = entPhysicalMfgName.7036 = entPhysicalMfgName.7038 = entPhysicalMfgName.7040 = entPhysicalMfgName.9000 = Cisco Systems Inc entPhysicalMfgName.9001 = Cisco Systems Inc entPhysicalModelName.1 = ISR4451-X/K9 entPhysicalModelName.2 = entPhysicalModelName.3 = PWR-4450-AC entPhysicalModelName.4 = entPhysicalModelName.5 = entPhysicalModelName.6 = entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.14 = entPhysicalModelName.22 = entPhysicalModelName.42 = entPhysicalModelName.43 = ACS-4450-FANASSY entPhysicalModelName.44 = entPhysicalModelName.45 = entPhysicalModelName.46 = entPhysicalModelName.47 = entPhysicalModelName.48 = entPhysicalModelName.54 = entPhysicalModelName.55 = entPhysicalModelName.56 = entPhysicalModelName.57 = entPhysicalModelName.62 = entPhysicalModelName.82 = entPhysicalModelName.102 = entPhysicalModelName.1000 = ISR4451-X/K9 entPhysicalModelName.1001 = entPhysicalModelName.1002 = entPhysicalModelName.1003 = entPhysicalModelName.1004 = entPhysicalModelName.1015 = ISR4451-X-4x1GE entPhysicalModelName.1016 = entPhysicalModelName.1017 = entPhysicalModelName.1018 = entPhysicalModelName.1019 = entPhysicalModelName.1046 = entPhysicalModelName.1056 = entPhysicalModelName.1066 = entPhysicalModelName.1076 = entPhysicalModelName.3000 = ISR4451-X/K9 entPhysicalModelName.3001 = entPhysicalModelName.5000 = ISR4451-X/K9 entPhysicalModelName.5001 = entPhysicalModelName.7000 = ISR4451-X/K9 entPhysicalModelName.7001 = entPhysicalModelName.7002 = entPhysicalModelName.7003 = entPhysicalModelName.7004 = entPhysicalModelName.7005 = entPhysicalModelName.7006 = entPhysicalModelName.7007 = entPhysicalModelName.7008 = entPhysicalModelName.7009 = entPhysicalModelName.7010 = entPhysicalModelName.7011 = entPhysicalModelName.7012 = entPhysicalModelName.7013 = entPhysicalModelName.7014 = entPhysicalModelName.7015 = entPhysicalModelName.7016 = entPhysicalModelName.7017 = entPhysicalModelName.7018 = entPhysicalModelName.7019 = entPhysicalModelName.7020 = entPhysicalModelName.7021 = entPhysicalModelName.7022 = entPhysicalModelName.7023 = entPhysicalModelName.7024 = entPhysicalModelName.7025 = entPhysicalModelName.7026 = entPhysicalModelName.7027 = entPhysicalModelName.7028 = entPhysicalModelName.7029 = entPhysicalModelName.7030 = entPhysicalModelName.7035 = entPhysicalModelName.7036 = entPhysicalModelName.7038 = entPhysicalModelName.7040 = entPhysicalModelName.9000 = ISR4451-X/K9 entPhysicalModelName.9001 = entPhysicalAlias.1 = entPhysicalAlias.2 = entPhysicalAlias.3 = entPhysicalAlias.4 = entPhysicalAlias.5 = entPhysicalAlias.6 = entPhysicalAlias.7 = entPhysicalAlias.8 = entPhysicalAlias.9 = entPhysicalAlias.10 = entPhysicalAlias.11 = entPhysicalAlias.12 = entPhysicalAlias.13 = entPhysicalAlias.14 = entPhysicalAlias.22 = entPhysicalAlias.42 = entPhysicalAlias.43 = entPhysicalAlias.44 = entPhysicalAlias.45 = entPhysicalAlias.46 = entPhysicalAlias.47 = entPhysicalAlias.48 = entPhysicalAlias.54 = entPhysicalAlias.55 = entPhysicalAlias.56 = entPhysicalAlias.57 = entPhysicalAlias.62 = entPhysicalAlias.82 = entPhysicalAlias.102 = entPhysicalAlias.1000 = entPhysicalAlias.1001 = entPhysicalAlias.1002 = entPhysicalAlias.1003 = entPhysicalAlias.1004 = entPhysicalAlias.1015 = entPhysicalAlias.1016 = entPhysicalAlias.1017 = entPhysicalAlias.1018 = entPhysicalAlias.1019 = entPhysicalAlias.1046 = entPhysicalAlias.1056 = entPhysicalAlias.1066 = entPhysicalAlias.1076 = entPhysicalAlias.3000 = entPhysicalAlias.3001 = entPhysicalAlias.5000 = entPhysicalAlias.5001 = entPhysicalAlias.7000 = entPhysicalAlias.7001 = entPhysicalAlias.7002 = entPhysicalAlias.7003 = entPhysicalAlias.7004 = entPhysicalAlias.7005 = entPhysicalAlias.7006 = entPhysicalAlias.7007 = entPhysicalAlias.7008 = entPhysicalAlias.7009 = entPhysicalAlias.7010 = entPhysicalAlias.7011 = entPhysicalAlias.7012 = entPhysicalAlias.7013 = entPhysicalAlias.7014 = entPhysicalAlias.7015 = entPhysicalAlias.7016 = entPhysicalAlias.7017 = entPhysicalAlias.7018 = entPhysicalAlias.7019 = entPhysicalAlias.7020 = entPhysicalAlias.7021 = entPhysicalAlias.7022 = entPhysicalAlias.7023 = entPhysicalAlias.7024 = entPhysicalAlias.7025 = entPhysicalAlias.7026 = entPhysicalAlias.7027 = entPhysicalAlias.7028 = entPhysicalAlias.7029 = entPhysicalAlias.7030 = entPhysicalAlias.7035 = entPhysicalAlias.7036 = entPhysicalAlias.7038 = entPhysicalAlias.7040 = entPhysicalAlias.9000 = entPhysicalAlias.9001 = entPhysicalAssetID.1 = entPhysicalAssetID.2 = entPhysicalAssetID.3 = entPhysicalAssetID.4 = entPhysicalAssetID.5 = entPhysicalAssetID.6 = entPhysicalAssetID.7 = entPhysicalAssetID.8 = entPhysicalAssetID.9 = entPhysicalAssetID.10 = entPhysicalAssetID.11 = entPhysicalAssetID.12 = entPhysicalAssetID.13 = entPhysicalAssetID.14 = entPhysicalAssetID.22 = entPhysicalAssetID.42 = entPhysicalAssetID.43 = entPhysicalAssetID.44 = entPhysicalAssetID.45 = entPhysicalAssetID.46 = entPhysicalAssetID.47 = entPhysicalAssetID.48 = entPhysicalAssetID.54 = entPhysicalAssetID.55 = entPhysicalAssetID.56 = entPhysicalAssetID.57 = entPhysicalAssetID.62 = entPhysicalAssetID.82 = entPhysicalAssetID.102 = entPhysicalAssetID.1000 = entPhysicalAssetID.1001 = entPhysicalAssetID.1002 = entPhysicalAssetID.1003 = entPhysicalAssetID.1004 = entPhysicalAssetID.1015 = entPhysicalAssetID.1016 = entPhysicalAssetID.1017 = entPhysicalAssetID.1018 = entPhysicalAssetID.1019 = entPhysicalAssetID.1046 = entPhysicalAssetID.1056 = entPhysicalAssetID.1066 = entPhysicalAssetID.1076 = entPhysicalAssetID.3000 = entPhysicalAssetID.3001 = entPhysicalAssetID.5000 = entPhysicalAssetID.5001 = entPhysicalAssetID.7000 = entPhysicalAssetID.7001 = entPhysicalAssetID.7002 = entPhysicalAssetID.7003 = entPhysicalAssetID.7004 = entPhysicalAssetID.7005 = entPhysicalAssetID.7006 = entPhysicalAssetID.7007 = entPhysicalAssetID.7008 = entPhysicalAssetID.7009 = entPhysicalAssetID.7010 = entPhysicalAssetID.7011 = entPhysicalAssetID.7012 = entPhysicalAssetID.7013 = entPhysicalAssetID.7014 = entPhysicalAssetID.7015 = entPhysicalAssetID.7016 = entPhysicalAssetID.7017 = entPhysicalAssetID.7018 = entPhysicalAssetID.7019 = entPhysicalAssetID.7020 = entPhysicalAssetID.7021 = entPhysicalAssetID.7022 = entPhysicalAssetID.7023 = entPhysicalAssetID.7024 = entPhysicalAssetID.7025 = entPhysicalAssetID.7026 = entPhysicalAssetID.7027 = entPhysicalAssetID.7028 = entPhysicalAssetID.7029 = entPhysicalAssetID.7030 = entPhysicalAssetID.7035 = entPhysicalAssetID.7036 = entPhysicalAssetID.7038 = entPhysicalAssetID.7040 = entPhysicalAssetID.9000 = entPhysicalAssetID.9001 = entPhysicalIsFRU.1 = true entPhysicalIsFRU.2 = false entPhysicalIsFRU.3 = true entPhysicalIsFRU.4 = false entPhysicalIsFRU.5 = false entPhysicalIsFRU.6 = false entPhysicalIsFRU.7 = false entPhysicalIsFRU.8 = false entPhysicalIsFRU.9 = false entPhysicalIsFRU.10 = false entPhysicalIsFRU.11 = false entPhysicalIsFRU.12 = false entPhysicalIsFRU.13 = false entPhysicalIsFRU.14 = false entPhysicalIsFRU.22 = false entPhysicalIsFRU.42 = false entPhysicalIsFRU.43 = true entPhysicalIsFRU.44 = false entPhysicalIsFRU.45 = false entPhysicalIsFRU.46 = false entPhysicalIsFRU.47 = false entPhysicalIsFRU.48 = false entPhysicalIsFRU.54 = false entPhysicalIsFRU.55 = false entPhysicalIsFRU.56 = false entPhysicalIsFRU.57 = false entPhysicalIsFRU.62 = false entPhysicalIsFRU.82 = false entPhysicalIsFRU.102 = false entPhysicalIsFRU.1000 = false entPhysicalIsFRU.1001 = false entPhysicalIsFRU.1002 = false entPhysicalIsFRU.1003 = false entPhysicalIsFRU.1004 = false entPhysicalIsFRU.1015 = false entPhysicalIsFRU.1016 = false entPhysicalIsFRU.1017 = false entPhysicalIsFRU.1018 = false entPhysicalIsFRU.1019 = false entPhysicalIsFRU.1046 = false entPhysicalIsFRU.1056 = false entPhysicalIsFRU.1066 = false entPhysicalIsFRU.1076 = false entPhysicalIsFRU.3000 = false entPhysicalIsFRU.3001 = false entPhysicalIsFRU.5000 = false entPhysicalIsFRU.5001 = false entPhysicalIsFRU.7000 = false entPhysicalIsFRU.7001 = false entPhysicalIsFRU.7002 = false entPhysicalIsFRU.7003 = false entPhysicalIsFRU.7004 = false entPhysicalIsFRU.7005 = false entPhysicalIsFRU.7006 = false entPhysicalIsFRU.7007 = false entPhysicalIsFRU.7008 = false entPhysicalIsFRU.7009 = false entPhysicalIsFRU.7010 = false entPhysicalIsFRU.7011 = false entPhysicalIsFRU.7012 = false entPhysicalIsFRU.7013 = false entPhysicalIsFRU.7014 = false entPhysicalIsFRU.7015 = false entPhysicalIsFRU.7016 = false entPhysicalIsFRU.7017 = false entPhysicalIsFRU.7018 = false entPhysicalIsFRU.7019 = false entPhysicalIsFRU.7020 = false entPhysicalIsFRU.7021 = false entPhysicalIsFRU.7022 = false entPhysicalIsFRU.7023 = false entPhysicalIsFRU.7024 = false entPhysicalIsFRU.7025 = false entPhysicalIsFRU.7026 = false entPhysicalIsFRU.7027 = false entPhysicalIsFRU.7028 = false entPhysicalIsFRU.7029 = false entPhysicalIsFRU.7030 = false entPhysicalIsFRU.7035 = false entPhysicalIsFRU.7036 = false entPhysicalIsFRU.7038 = false entPhysicalIsFRU.7040 = false entPhysicalIsFRU.9000 = false entPhysicalIsFRU.9001 = false entPhysicalMfgDate.1 = 0-0-0,0:0:0.0 entPhysicalMfgDate.2 = 0-0-0,0:0:0.0 entPhysicalMfgDate.3 = 0-0-0,0:0:0.0 entPhysicalMfgDate.4 = 0-0-0,0:0:0.0 entPhysicalMfgDate.5 = 0-0-0,0:0:0.0 entPhysicalMfgDate.6 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7 = 0-0-0,0:0:0.0 entPhysicalMfgDate.8 = 0-0-0,0:0:0.0 entPhysicalMfgDate.9 = 0-0-0,0:0:0.0 entPhysicalMfgDate.10 = 0-0-0,0:0:0.0 entPhysicalMfgDate.11 = 0-0-0,0:0:0.0 entPhysicalMfgDate.12 = 0-0-0,0:0:0.0 entPhysicalMfgDate.13 = 0-0-0,0:0:0.0 entPhysicalMfgDate.14 = 0-0-0,0:0:0.0 entPhysicalMfgDate.22 = 0-0-0,0:0:0.0 entPhysicalMfgDate.42 = 0-0-0,0:0:0.0 entPhysicalMfgDate.43 = 0-0-0,0:0:0.0 entPhysicalMfgDate.44 = 0-0-0,0:0:0.0 entPhysicalMfgDate.45 = 0-0-0,0:0:0.0 entPhysicalMfgDate.46 = 0-0-0,0:0:0.0 entPhysicalMfgDate.47 = 0-0-0,0:0:0.0 entPhysicalMfgDate.48 = 0-0-0,0:0:0.0 entPhysicalMfgDate.54 = 0-0-0,0:0:0.0 entPhysicalMfgDate.55 = 0-0-0,0:0:0.0 entPhysicalMfgDate.56 = 0-0-0,0:0:0.0 entPhysicalMfgDate.57 = 0-0-0,0:0:0.0 entPhysicalMfgDate.62 = 0-0-0,0:0:0.0 entPhysicalMfgDate.82 = 0-0-0,0:0:0.0 entPhysicalMfgDate.102 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1000 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1001 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1002 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1003 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1004 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1015 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1016 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1017 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1018 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1019 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1046 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1056 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1066 = 0-0-0,0:0:0.0 entPhysicalMfgDate.1076 = 0-0-0,0:0:0.0 entPhysicalMfgDate.3000 = 0-0-0,0:0:0.0 entPhysicalMfgDate.3001 = 0-0-0,0:0:0.0 entPhysicalMfgDate.5000 = 0-0-0,0:0:0.0 entPhysicalMfgDate.5001 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7000 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7001 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7002 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7003 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7004 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7005 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7006 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7007 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7008 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7009 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7010 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7011 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7012 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7013 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7014 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7015 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7016 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7017 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7018 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7019 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7020 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7021 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7022 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7023 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7024 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7025 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7026 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7027 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7028 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7029 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7030 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7035 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7036 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7038 = 0-0-0,0:0:0.0 entPhysicalMfgDate.7040 = 0-0-0,0:0:0.0 entPhysicalMfgDate.9000 = 0-0-0,0:0:0.0 entPhysicalMfgDate.9001 = 0-0-0,0:0:0.0 entPhysicalUris.1 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.2 = "" entPhysicalUris.3 = "URN:CLEI:IPUPANZAAA" entPhysicalUris.4 = "" entPhysicalUris.5 = "" entPhysicalUris.6 = "" entPhysicalUris.7 = "" entPhysicalUris.8 = "" entPhysicalUris.9 = "" entPhysicalUris.10 = "" entPhysicalUris.11 = "" entPhysicalUris.12 = "" entPhysicalUris.13 = "" entPhysicalUris.14 = "" entPhysicalUris.22 = "" entPhysicalUris.42 = "" entPhysicalUris.43 = "" entPhysicalUris.44 = "" entPhysicalUris.45 = "" entPhysicalUris.46 = "" entPhysicalUris.47 = "" entPhysicalUris.48 = "" entPhysicalUris.54 = "" entPhysicalUris.55 = "" entPhysicalUris.56 = "" entPhysicalUris.57 = "" entPhysicalUris.62 = "" entPhysicalUris.82 = "" entPhysicalUris.102 = "" entPhysicalUris.1000 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.1001 = "" entPhysicalUris.1002 = "" entPhysicalUris.1003 = "" entPhysicalUris.1004 = "" entPhysicalUris.1015 = "URN:CLEI:CNUIAHSAAA" entPhysicalUris.1016 = "" entPhysicalUris.1017 = "" entPhysicalUris.1018 = "" entPhysicalUris.1019 = "" entPhysicalUris.1046 = "" entPhysicalUris.1056 = "" entPhysicalUris.1066 = "" entPhysicalUris.1076 = "" entPhysicalUris.3000 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.3001 = "" entPhysicalUris.5000 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.5001 = "" entPhysicalUris.7000 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.7001 = "" entPhysicalUris.7002 = "" entPhysicalUris.7003 = "" entPhysicalUris.7004 = "" entPhysicalUris.7005 = "" entPhysicalUris.7006 = "" entPhysicalUris.7007 = "" entPhysicalUris.7008 = "" entPhysicalUris.7009 = "" entPhysicalUris.7010 = "" entPhysicalUris.7011 = "" entPhysicalUris.7012 = "" entPhysicalUris.7013 = "" entPhysicalUris.7014 = "" entPhysicalUris.7015 = "" entPhysicalUris.7016 = "" entPhysicalUris.7017 = "" entPhysicalUris.7018 = "" entPhysicalUris.7019 = "" entPhysicalUris.7020 = "" entPhysicalUris.7021 = "" entPhysicalUris.7022 = "" entPhysicalUris.7023 = "" entPhysicalUris.7024 = "" entPhysicalUris.7025 = "" entPhysicalUris.7026 = "" entPhysicalUris.7027 = "" entPhysicalUris.7028 = "" entPhysicalUris.7029 = "" entPhysicalUris.7030 = "" entPhysicalUris.7035 = "" entPhysicalUris.7036 = "" entPhysicalUris.7038 = "" entPhysicalUris.7040 = "" entPhysicalUris.9000 = "URN:CLEI:IPM9C10CRA" entPhysicalUris.9001 = "" entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier.1016.0 = ifIndex.1 entAliasMappingIdentifier.1017.0 = ifIndex.2 entAliasMappingIdentifier.1018.0 = ifIndex.3 entAliasMappingIdentifier.1019.0 = ifIndex.4 entAliasMappingIdentifier.7040.0 = ifIndex.5 SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1][0m 0.24ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1,"Cisco ISR4451 Chassis","chassis","Chassis","ISR4451-X\/K9","FJC2006D0AE","0","Cisco Systems Inc","-1","cevChassis.1248","V06","","","true","","",7,1][0m 0.76ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,2][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[2,"Power Supply Bay","container","Power Supply Bay 0","","","1","","9","cevContainer.269","","","","false","","",7,2][0m 0.46ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,3][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[3,"450W AC Power Supply for Cisco ISR4450, ISR4350","powerSupply","Power Supply Module 0","PWR-4450-AC","DCA1949X11S","2","Cisco Systems Inc","0","cevPowerSupply.346","V02","","","true","","",7,3][0m 0.48ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,4][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[4,"Temp: Temp 1","sensor","Temp: Temp 1 P0\/0","","","3","","0","cevSensorModuleDeviceTemp","","","","false","","",7,4][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,5][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[5,"Temp: Temp 2","sensor","Temp: Temp 2 P0\/1","","","3","","1","cevSensorModuleDeviceTemp","","","","false","","",7,5][0m 0.43ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,6][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[6,"Temp: Temp 3","sensor","Temp: Temp 3 P0\/2","","","3","","2","cevSensorModuleDeviceTemp","","","","false","","",7,6][0m 0.4ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7,"V: PEM Out","sensor","V: PEM Out P0\/3","","","3","","3","cevSensorModuleDeviceVoltage","","","","false","","",7,7][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,8][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[8,"I: PEM In","sensor","I: PEM In P0\/4","","","3","","4","cevSensorModuleDeviceCurrent","","","","false","","",7,8][0m 0.43ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,9][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[9,"I: PEM Out","sensor","I: PEM Out P0\/5","","","3","","5","cevSensorModuleDeviceCurrent","","","","false","","",7,9][0m 0.41ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,10][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[10,"P: In pwr","sensor","P: In pwr P0\/6","","","3","","6","cevSensor.132","","","","false","","",7,10][0m 0.46ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,11][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[11,"P: Out pwr","sensor","P: Out pwr P0\/7","","","3","","7","cevSensor.132","","","","false","","",7,11][0m 0.49ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,12][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[12,"RPM: fan0","sensor","RPM: fan0 P0\/8","","","3","","8","cevSensor.133","","","","false","","",7,12][0m 0.48ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,13][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[13,"Power Supply","powerSupply","Power Supply 0","","","3","","0","cevPowerSupply.364","","","","false","","",7,13][0m 0.45ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,14][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[14,"Fan","fan","Fan 0\/0","","","3","","0","cevFan.195","","","","false","","",7,14][0m 0.46ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,22][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[22,"Power Supply Bay","container","Power Supply Bay 1","","","1","","10","cevContainer.269","","","","false","","",7,22][0m 0.46ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,42][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[42,"Fan Tray Bay","container","Fan Tray Bay 0","","","1","","11","cevContainer.270","","","","false","","",7,42][0m 0.47ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,43][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[43,"Cisco ISR4450, ISR4350 Fan Assembly","fan","Fan Tray","ACS-4450-FANASSY","","42","Cisco Systems Inc","0","cevFan.185","","","","true","","",7,43][0m 0.43ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,44][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[44,"RPM: fan0","sensor","RPM: fan0 P2\/0","","","43","","0","cevSensor.133","","","","false","","",7,44][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,45][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[45,"RPM: fan1","sensor","RPM: fan1 P2\/1","","","43","","1","cevSensor.133","","","","false","","",7,45][0m 0.43ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,46][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[46,"RPM: fan2","sensor","RPM: fan2 P2\/2","","","43","","2","cevSensor.133","","","","false","","",7,46][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,47][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[47,"RPM: fan3","sensor","RPM: fan3 P2\/3","","","43","","3","cevSensor.133","","","","false","","",7,47][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,48][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[48,"P: pwr","sensor","P: pwr P2\/4","","","43","","4","cevSensor.132","","","","false","","",7,48][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,54][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[54,"Fan","fan","Fan 2\/0","","","43","","0","cevFan.195","","","","false","","",7,54][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,55][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[55,"Fan","fan","Fan 2\/1","","","43","","1","cevFan.195","","","","false","","",7,55][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,56][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[56,"Fan","fan","Fan 2\/2","","","43","","2","cevFan.195","","","","false","","",7,56][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,57][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[57,"Fan","fan","Fan 2\/3","","","43","","3","cevFan.195","","","","false","","",7,57][0m 0.41ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,62][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[62,"POE Bay","container","POE Bay 0","","","1","","12","cevContainer.271","","","","false","","",7,62][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,82][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[82,"POE Bay","container","POE Bay 1","","","1","","13","cevContainer.271","","","","false","","",7,82][0m 0.39ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,102][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[102,"Internal POE Bay","container","Internal POE Bay 0","","","1","","14","cevContainer.272","","","","false","","",7,102][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1000][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1000,"Cisco ISR4451 Built-In NIM controller","module","module 0","ISR4451-X\/K9","","1","Cisco Systems Inc","0","cevModule.92.14","","15.4(3r)S","03.13.04.S.154-3.S4-ext","false","","",7,1000][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1001][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1001,"Network Interface Module Subslot","container","subslot 0\/1","","","1000","","1","cevContainer.323","","","","false","","",7,1001][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1002][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1002,"Network Interface Module Subslot","container","subslot 0\/2","","","1000","","2","cevContainer.323","","","","false","","",7,1002][0m 0.39ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1003][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1003,"Network Interface Module Subslot","container","subslot 0\/3","","","1000","","3","cevContainer.323","","","","false","","",7,1003][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1004][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1004,"Packet Voice DSP Module Subslot","container","subslot 0\/4","","","1000","","4","cevContainer.324","","","","false","","",7,1004][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1015][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1015,"Front Panel 4 ports Gigabitethernet Module","module","NIM subslot 0\/0","ISR4451-X-4x1GE","JAB092709EL","1000","Cisco Systems Inc","0","cevModule.92.21","V01","","","false","","",7,1015][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1016][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1016,"ISR4451-X-4x1GE","port","GigabitEthernet0\/0\/0","","","1015","","0","cevPortGe","","","","false","","",7,1016][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1017][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1017,"ISR4451-X-4x1GE","port","GigabitEthernet0\/0\/1","","","1015","","1","cevPortGe","","","","false","","",7,1017][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1018][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1018,"ISR4451-X-4x1GE","port","GigabitEthernet0\/0\/2","","","1015","","2","cevPortGe","","","","false","","",7,1018][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1019][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1019,"ISR4451-X-4x1GE","port","GigabitEthernet0\/0\/3","","","1015","","3","cevPortGe","","","","false","","",7,1019][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1046][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1046,"subslot 0\/0 transceiver container 0","container","subslot 0\/0 transceiver container 0","","","1015","","0","cevContainerSFP","","","","false","","",7,1046][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1056][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1056,"subslot 0\/0 transceiver container 1","container","subslot 0\/0 transceiver container 1","","","1015","","1","cevContainerSFP","","","","false","","",7,1056][0m 0.34ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1066][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1066,"subslot 0\/0 transceiver container 2","container","subslot 0\/0 transceiver container 2","","","1015","","2","cevContainerSFP","","","","false","","",7,1066][0m 0.35ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,1076][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[1076,"subslot 0\/0 transceiver container 3","container","subslot 0\/0 transceiver container 3","","","1015","","3","cevContainerSFP","","","","false","","",7,1076][0m 0.41ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,3000][0m 0.15ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[3000,"Cisco ISR4451 Built-In SM controller","module","module 1","ISR4451-X\/K9","","1","Cisco Systems Inc","1","cevModule.92.19","","15.4(3r)S","03.13.04.S.154-3.S4-ext","false","","",7,3000][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,3001][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[3001,"Enhanced Service Module Slot","container","slot 1","","","3000","","0","cevContainer.268","","","","false","","",7,3001][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,5000][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[5000,"Cisco ISR4451 Built-In SM controller","module","module 2","ISR4451-X\/K9","","1","Cisco Systems Inc","2","cevModule.92.19","","15.4(3r)S","03.13.04.S.154-3.S4-ext","false","","",7,5000][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,5001][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[5001,"Enhanced Service Module Slot","container","slot 2","","","5000","","0","cevContainer.268","","","","false","","",7,5001][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7000][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7000,"Cisco ISR4451 Route Processor","module","module R0","ISR4451-X\/K9","FOC19515Y3Z","1","Cisco Systems Inc","6","cevModule.92.3","V06","15.4(3r)S","03.13.04.S.154-3.S4-ext","false","","",7,7000][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7001][0m 0.16ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7001,"Temp: Inlet 1","sensor","Temp: Inlet 1 R0\/0","","","7000","","0","cevSensorModuleDeviceTemp","","","","false","","",7,7001][0m 0.9ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7002][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7002,"Temp: Inlet 2","sensor","Temp: Inlet 2 R0\/1","","","7000","","1","cevSensorModuleDeviceTemp","","","","false","","",7,7002][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7003][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7003,"Temp: Outlet 1","sensor","Temp: Outlet 1 R0\/2","","","7000","","2","cevSensorModuleDeviceTemp","","","","false","","",7,7003][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7004][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7004,"Temp: Outlet 2","sensor","Temp: Outlet 2 R0\/3","","","7000","","3","cevSensorModuleDeviceTemp","","","","false","","",7,7004][0m 0.37ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7005][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7005,"Temp: core-A","sensor","Temp: core-A R0\/4","","","7000","","4","cevSensorModuleDeviceTemp","","","","false","","",7,7005][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7006][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7006,"Temp: core-B","sensor","Temp: core-B R0\/5","","","7000","","5","cevSensorModuleDeviceTemp","","","","false","","",7,7006][0m 0.35ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7007][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7007,"Temp: core-C","sensor","Temp: core-C R0\/6","","","7000","","6","cevSensorModuleDeviceTemp","","","","false","","",7,7007][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7008][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7008,"V: 12v","sensor","V: 12v R0\/7","","","7000","","7","cevSensorModuleDeviceVoltage","","","","false","","",7,7008][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7009][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7009,"V: 5v","sensor","V: 5v R0\/8","","","7000","","8","cevSensorModuleDeviceVoltage","","","","false","","",7,7009][0m 0.33ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7010][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7010,"V: 3.3v","sensor","V: 3.3v R0\/9","","","7000","","9","cevSensorModuleDeviceVoltage","","","","false","","",7,7010][0m 0.33ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7011][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7011,"V: 3.0v","sensor","V: 3.0v R0\/10","","","7000","","10","cevSensorModuleDeviceVoltage","","","","false","","",7,7011][0m 0.33ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7012][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7012,"V: 2.5v","sensor","V: 2.5v R0\/11","","","7000","","11","cevSensorModuleDeviceVoltage","","","","false","","",7,7012][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7013][0m 0.14ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7013,"V: 1.05v","sensor","V: 1.05v R0\/12","","","7000","","12","cevSensorModuleDeviceVoltage","","","","false","","",7,7013][0m 0.48ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7014][0m 0.13ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7014,"V: 1.8v","sensor","V: 1.8v R0\/13","","","7000","","13","cevSensorModuleDeviceVoltage","","","","false","","",7,7014][0m 3.77ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7015][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7015,"V: 1.2v","sensor","V: 1.2v R0\/14","","","7000","","14","cevSensorModuleDeviceVoltage","","","","false","","",7,7015][0m 0.48ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7016][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7016,"V: Vcore-C","sensor","V: Vcore-C R0\/15","","","7000","","15","cevSensorModuleDeviceVoltage","","","","false","","",7,7016][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7017][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7017,"V: 1.1v","sensor","V: 1.1v R0\/16","","","7000","","16","cevSensorModuleDeviceVoltage","","","","false","","",7,7017][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7018][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7018,"V: 1.0v","sensor","V: 1.0v R0\/17","","","7000","","17","cevSensorModuleDeviceVoltage","","","","false","","",7,7018][0m 0.45ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7019][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7019,"V: 1.8v-A","sensor","V: 1.8v-A R0\/18","","","7000","","18","cevSensorModuleDeviceVoltage","","","","false","","",7,7019][0m 0.39ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7020][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7020,"V: 1.5v-A","sensor","V: 1.5v-A R0\/19","","","7000","","19","cevSensorModuleDeviceVoltage","","","","false","","",7,7020][0m 1.09ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7021][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7021,"V: 1.5v-C1","sensor","V: 1.5v-C1 R0\/20","","","7000","","20","cevSensorModuleDeviceVoltage","","","","false","","",7,7021][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7022][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7022,"V: 1.5v-B","sensor","V: 1.5v-B R0\/21","","","7000","","21","cevSensorModuleDeviceVoltage","","","","false","","",7,7022][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7023][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7023,"V: Vcore-A","sensor","V: Vcore-A R0\/22","","","7000","","22","cevSensorModuleDeviceVoltage","","","","false","","",7,7023][0m 0.4ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7024][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7024,"V: 1.5v-C2","sensor","V: 1.5v-C2 R0\/23","","","7000","","23","cevSensorModuleDeviceVoltage","","","","false","","",7,7024][0m 0.4ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7025][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7025,"V: Vcore-B1","sensor","V: Vcore-B1 R0\/24","","","7000","","24","cevSensorModuleDeviceVoltage","","","","false","","",7,7025][0m 0.47ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7026][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7026,"V: Vcore-B2","sensor","V: Vcore-B2 R0\/25","","","7000","","25","cevSensorModuleDeviceVoltage","","","","false","","",7,7026][0m 0.5ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7027][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7027,"V: 0.75v-B","sensor","V: 0.75v-B R0\/26","","","7000","","26","cevSensorModuleDeviceVoltage","","","","false","","",7,7027][0m 0.44ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7028][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7028,"V: 0.75v-C","sensor","V: 0.75v-C R0\/27","","","7000","","27","cevSensorModuleDeviceVoltage","","","","false","","",7,7028][0m 0.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7029][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7029,"I: 12v","sensor","I: 12v R0\/28","","","7000","","28","cevSensorModuleDeviceCurrent","","","","false","","",7,7029][0m 0.46ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7030][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7030,"P: pwr","sensor","P: pwr R0\/29","","","7000","","29","cevSensor.132","","","","false","","",7,7030][0m 0.49ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7035][0m 0.1ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7035,"CPU 0 of module R0","cpu","cpu R0\/0","","","7000","","0","cevModuleCpuType","","","","false","","",7,7035][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7036][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7036,"USB Port","container","usb R0\/0","","","7000","","0","cevContainer.333","","","","false","","",7,7036][0m 0.38ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7038][0m 0.09ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7038,"USB Port","container","usb R0\/1","","","7000","","1","cevContainer.333","","","","false","","",7,7038][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,7040][0m 0.12ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[7040,"Network Management Ethernet","port","NME R0","","","7000","","2","cevPortGe","","","","false","","",7,7040][0m 0.36ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,9000][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[9000,"Cisco ISR4451 Forwarding Processor","module","module F0","ISR4451-X\/K9","","1","Cisco Systems Inc","8","cevModule.92.8","","15.4(3r)S","03.13.04.S.154-3.S4-ext","false","","",7,9000][0m 0.32ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[7,9001][0m 0.11ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[9001,"QFP 0 of module F0","cpu","qfp F0\/0","","","9000","Cisco Systems Inc","0","cevModuleCpuType","","","","false","","",7,9001][0m 0.31ms] . SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[7][0m 0.27ms] >> Runtime for discovery module 'entity-physical': 0.2400 seconds with 25848 bytes >> SNMP: [1/0.17s] MySQL: [85/0.05s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-PROCESS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpmCPU[0m] cpmCPUTotalPhysicalIndex[7] = 7035 cpmCPUTotal5sec[7] = 3 cpmCPUTotal1min[7] = 2 cpmCPUTotal5min[7] = 2 cpmCPUTotal5secRev[7] = 3 cpmCPUTotal1minRev[7] = 2 cpmCPUTotal5minRev[7] = 2 cpmCPUMonInterval[7] = 0 cpmCPUTotalMonIntervalValue[7] = 0 cpmCPUInterruptMonIntervalValue[7] = 0 cpmCPUMemoryUsed[7] = 3294064 cpmCPUMemoryFree[7] = 677988 cpmCPUMemoryKernelReserved[7] = 0 cpmCPUMemoryLowest[7] = 644688 cpmCPUMemoryUsedOvrflw[7] = 0 cpmCPUMemoryHCUsed[7] = 3294064 cpmCPUMemoryFreeOvrflw[7] = 0 cpmCPUMemoryHCFree[7] = 677988 cpmCPUMemoryKernelReservedOvrflw[7] = 0 cpmCPUMemoryHCKernelReserved[7] = 0 cpmCPUMemoryLowestOvrflw[7] = 0 cpmCPUMemoryHCLowest[7] = 644688 cpmCPULoadAvg1min[7] = 0 cpmCPULoadAvg5min[7] = 0 cpmCPULoadAvg15min[7] = 0 cpmCPUMemoryCommitted[7] = 1578432 cpmCPUMemoryCommittedOvrflw[7] = 0 cpmCPUMemoryHCCommitted[7] = 1578432 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName.7035[0m] cpu R0/0 Discovered LibreNMS\Device\Processor Array ( [processor_id] => [entPhysicalIndex] => 7035 [hrDeviceIndex] => 0 [device_id] => 7 [processor_oid] => .1.3.6.1.4.1.9.9.109.1.1.1.1.8.7 [processor_index] => 7 [processor_type] => cpm [processor_usage] => 2 [processor_descr] => cpu R0/0 [processor_precision] => 1 [processor_perc_warn] => 75 ) SQL[[1;33mSELECT * FROM `processors` WHERE device_id=? AND processor_index=? AND processor_type=? [0;33m[7,"7","cpm"][0m 0.33ms] .SQL[[1;33mSELECT * FROM `processors` WHERE device_id=? AND processor_index=? AND processor_type=? [0;33m[7,"7","cpm"][0m 0.2ms] .SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? AND `processor_id` NOT IN (?,?) [0;33m[7,11,11][0m 0.19ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.98ms] >> Runtime for discovery module 'processors': 0.0200 seconds with 60312 bytes >> SNMP: [1/0.01s] MySQL: [4/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### CISCO-ENHANCED-MEMORY-POOL: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENHANCED-MEMPOOL-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cempMemPoolEntry[0m] cempMemPoolType.7000.1 = processorMemory cempMemPoolName.7000.1 = Processor cempMemPoolPlatformMemory.7000.1 = zeroDotZero cempMemPoolAlternate.7000.1 = 0 cempMemPoolValid.7000.1 = true cempMemPoolUsed.7000.1 = 226622056 cempMemPoolFree.7000.1 = 1501006696 cempMemPoolLargestFree.7000.1 = 1048575908 cempMemPoolLowestFree.7000.1 = 678975912 cempMemPoolUsedOvrflw.7000.1 = 0 cempMemPoolHCUsed.7000.1 = 226622056 cempMemPoolFreeOvrflw.7000.1 = 0 cempMemPoolHCFree.7000.1 = 1501006696 cempMemPoolLargestFreeOvrflw.7000.1 = 0 cempMemPoolHCLargestFree.7000.1 = 1048575908 cempMemPoolLowestFreeOvrflw.7000.1 = 0 cempMemPoolHCLowestFree.7000.1 = 678975912 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName.7000[0m] module R0 Discover Mempool: 7000.1, cemp, Module R0 - Processor, 1, 7000, SQL[[1;33mSELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = ? AND `device_id` = ? AND `mempool_type` = ? [0;33m["7000.1",7,"cemp"][0m 0.31ms] .SQL[[1;33mUPDATE `mempools` set `mempool_descr`=?,`entPhysicalIndex`=? WHERE device_id=? AND mempool_index=? AND mempool_type=? [0;33m["Module R0 - Processor","7000",7,"7000.1","cemp"][0m 0.46ms] SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[7][0m 0.25ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID Array ( [cemp] => Array ( [7000.1] => 1 ) ) SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '7' [0;33m[][0m 0.47ms] 7000.1 -> cemp >> Runtime for discovery module 'mempools': 0.0660 seconds with 38560 bytes >> SNMP: [5/0.06s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[7][0m 0.28ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2664 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS+ Device #### Load disco module cisco-mac-accounting #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqn -m CISCO-IP-STAT-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cipMacSwitchedBytes[0m] .*.*.*.1.4 No Such Instance currently exists at this OID SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,""][0m 1.32ms] >> Runtime for discovery module 'cisco-mac-accounting': 0.0110 seconds with 3640 bytes >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-mac-accounting #### Modules status: Global- OS+ Device #### Load disco module cisco-pw #### SQL[[1;33mSELECT * FROM `pseudowires` WHERE `device_id` = ? [0;33m[7][0m 0.33ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcID[0m] cpwVcID = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcName[0m] cpwVcName = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcType[0m] cpwVcType = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcPsnType[0m] cpwVcPsnType = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcDescr[0m] cpwVcDescr = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-IETF-PW-MPLS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cpwVcMplsPeerLdpID[0m] cpwVcMplsPeerLdpID = No Such Object available on this agent at this OID >> Runtime for discovery module 'cisco-pw': 0.0710 seconds with 3656 bytes >> SNMP: [6/0.07s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-pw #### Modules status: Global- OS+ Device #### Load disco module vrf #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m MPLS-L3VPN-STD-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 mplsL3VpnVrfRD[0m] .*.*.*.1.4 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m MPLS-VPN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 mplsVpnVrfRouteDistinguisher[0m] .*.*.2.1.3 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m CISCO-VRF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cvVrfName[0m] .*.*.7*.1.2.1 Mgmt-intf [DEBUG] Using CISCO-VRF-MIB [/DEBUG] [DEBUG OIDS] 1 Mgmt-intf [/DEBUG] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m CISCO-VRF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.711.1.2.1.1.2[0m] .*.*.7*.* vrfEdge [VRF Mgmt-intf] OID - 1 [VRF Mgmt-intf] RD - [VRF Mgmt-intf] DESC - SQL[[1;33mSELECT COUNT(*) FROM vrfs WHERE device_id = ? AND `vrf_oid`=? [0;33m[7,"1"][0m 0.31ms] SQL[[1;33mUPDATE `vrfs` set `mplsVpnVrfDescription`=?,`mplsVpnVrfRouteDistinguisher`=? WHERE device_id=? AND vrf_oid=? [0;33m[null,null,7,"1"][0m 0.45ms] SQL[[1;33mSELECT vrf_id FROM vrfs WHERE device_id = ? AND `vrf_oid`=? [0;33m[7,"1"][0m 0.14ms] [VRF Mgmt-intf] PORTS - SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,"5"][0m 0.27ms] Gi0 SQL[[1;33mUPDATE `ports` set `ifVrf`=? WHERE port_id=? [0;33m[16,237][0m 0.32ms] SQL[[1;33mSELECT * FROM ports WHERE device_id = '7' [0;33m[][0m 0.31ms] .SQL[[1;33mSELECT * FROM vrfs WHERE device_id = '7' [0;33m[][0m 0.12ms] . >> Runtime for discovery module 'vrf': 0.0410 seconds with 27544 bytes >> SNMP: [4/0.04s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module vrf #### Modules status: Global- OS+ Device #### Load disco module cisco-cef #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 CISCO-CEF-MIB::cefSwitchingPath[0m] cefSwitchingPath.7035.ipv4.1 = RP RIB cefSwitchingPath.7035.ipv4.2 = RP LES cefSwitchingPath.7035.ipv6.1 = RP LES cefSwitchingPath.7035.ipv4.1 = RP RIB || cefSwitchingPath || 7035 || ipv4 || 1 cefSwitchingPath.7035.ipv4.2 = RP LES || cefSwitchingPath || 7035 || ipv4 || 2 cefSwitchingPath.7035.ipv6.1 = RP LES || cefSwitchingPath || 7035 || ipv6 || 1 Array ( [7035] => Array ( [ipv4] => Array ( [1] => Array ( [cefSwitchingPath] => RP RIB ) [2] => Array ( [cefSwitchingPath] => RP LES ) ) [ipv6] => Array ( [1] => Array ( [cefSwitchingPath] => RP LES ) ) ) ) Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr.1 = Cisco ISR4451 Chassis entPhysicalDescr.2 = Power Supply Bay entPhysicalDescr.3 = 450W AC Power Supply for Cisco ISR4450, ISR4350 entPhysicalDescr.4 = Temp: Temp 1 entPhysicalDescr.5 = Temp: Temp 2 entPhysicalDescr.6 = Temp: Temp 3 entPhysicalDescr.7 = V: PEM Out entPhysicalDescr.8 = I: PEM In entPhysicalDescr.9 = I: PEM Out entPhysicalDescr.10 = P: In pwr entPhysicalDescr.11 = P: Out pwr entPhysicalDescr.12 = RPM: fan0 entPhysicalDescr.13 = Power Supply entPhysicalDescr.14 = Fan entPhysicalDescr.22 = Power Supply Bay entPhysicalDescr.42 = Fan Tray Bay entPhysicalDescr.43 = Cisco ISR4450, ISR4350 Fan Assembly entPhysicalDescr.44 = RPM: fan0 entPhysicalDescr.45 = RPM: fan1 entPhysicalDescr.46 = RPM: fan2 entPhysicalDescr.47 = RPM: fan3 entPhysicalDescr.48 = P: pwr entPhysicalDescr.54 = Fan entPhysicalDescr.55 = Fan entPhysicalDescr.56 = Fan entPhysicalDescr.57 = Fan entPhysicalDescr.62 = POE Bay entPhysicalDescr.82 = POE Bay entPhysicalDescr.102 = Internal POE Bay entPhysicalDescr.1000 = Cisco ISR4451 Built-In NIM controller entPhysicalDescr.1001 = Network Interface Module Subslot entPhysicalDescr.1002 = Network Interface Module Subslot entPhysicalDescr.1003 = Network Interface Module Subslot entPhysicalDescr.1004 = Packet Voice DSP Module Subslot entPhysicalDescr.1015 = Front Panel 4 ports Gigabitethernet Module entPhysicalDescr.1016 = ISR4451-X-4x1GE entPhysicalDescr.1017 = ISR4451-X-4x1GE entPhysicalDescr.1018 = ISR4451-X-4x1GE entPhysicalDescr.1019 = ISR4451-X-4x1GE entPhysicalDescr.1046 = subslot 0/0 transceiver container 0 entPhysicalDescr.1056 = subslot 0/0 transceiver container 1 entPhysicalDescr.1066 = subslot 0/0 transceiver container 2 entPhysicalDescr.1076 = subslot 0/0 transceiver container 3 entPhysicalDescr.3000 = Cisco ISR4451 Built-In SM controller entPhysicalDescr.3001 = Enhanced Service Module Slot entPhysicalDescr.5000 = Cisco ISR4451 Built-In SM controller entPhysicalDescr.5001 = Enhanced Service Module Slot entPhysicalDescr.7000 = Cisco ISR4451 Route Processor entPhysicalDescr.7001 = Temp: Inlet 1 entPhysicalDescr.7002 = Temp: Inlet 2 entPhysicalDescr.7003 = Temp: Outlet 1 entPhysicalDescr.7004 = Temp: Outlet 2 entPhysicalDescr.7005 = Temp: core-A entPhysicalDescr.7006 = Temp: core-B entPhysicalDescr.7007 = Temp: core-C entPhysicalDescr.7008 = V: 12v entPhysicalDescr.7009 = V: 5v entPhysicalDescr.7010 = V: 3.3v entPhysicalDescr.7011 = V: 3.0v entPhysicalDescr.7012 = V: 2.5v entPhysicalDescr.7013 = V: 1.05v entPhysicalDescr.7014 = V: 1.8v entPhysicalDescr.7015 = V: 1.2v entPhysicalDescr.7016 = V: Vcore-C entPhysicalDescr.7017 = V: 1.1v entPhysicalDescr.7018 = V: 1.0v entPhysicalDescr.7019 = V: 1.8v-A entPhysicalDescr.7020 = V: 1.5v-A entPhysicalDescr.7021 = V: 1.5v-C1 entPhysicalDescr.7022 = V: 1.5v-B entPhysicalDescr.7023 = V: Vcore-A entPhysicalDescr.7024 = V: 1.5v-C2 entPhysicalDescr.7025 = V: Vcore-B1 entPhysicalDescr.7026 = V: Vcore-B2 entPhysicalDescr.7027 = V: 0.75v-B entPhysicalDescr.7028 = V: 0.75v-C entPhysicalDescr.7029 = I: 12v entPhysicalDescr.7030 = P: pwr entPhysicalDescr.7035 = CPU 0 of module R0 entPhysicalDescr.7036 = USB Port entPhysicalDescr.7038 = USB Port entPhysicalDescr.7040 = Network Management Ethernet entPhysicalDescr.9000 = Cisco ISR4451 Forwarding Processor entPhysicalDescr.9001 = QFP 0 of module F0 entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName.1 = Chassis entPhysicalName.2 = Power Supply Bay 0 entPhysicalName.3 = Power Supply Module 0 entPhysicalName.4 = Temp: Temp 1 P0/0 entPhysicalName.5 = Temp: Temp 2 P0/1 entPhysicalName.6 = Temp: Temp 3 P0/2 entPhysicalName.7 = V: PEM Out P0/3 entPhysicalName.8 = I: PEM In P0/4 entPhysicalName.9 = I: PEM Out P0/5 entPhysicalName.10 = P: In pwr P0/6 entPhysicalName.11 = P: Out pwr P0/7 entPhysicalName.12 = RPM: fan0 P0/8 entPhysicalName.13 = Power Supply 0 entPhysicalName.14 = Fan 0/0 entPhysicalName.22 = Power Supply Bay 1 entPhysicalName.42 = Fan Tray Bay 0 entPhysicalName.43 = Fan Tray entPhysicalName.44 = RPM: fan0 P2/0 entPhysicalName.45 = RPM: fan1 P2/1 entPhysicalName.46 = RPM: fan2 P2/2 entPhysicalName.47 = RPM: fan3 P2/3 entPhysicalName.48 = P: pwr P2/4 entPhysicalName.54 = Fan 2/0 entPhysicalName.55 = Fan 2/1 entPhysicalName.56 = Fan 2/2 entPhysicalName.57 = Fan 2/3 entPhysicalName.62 = POE Bay 0 entPhysicalName.82 = POE Bay 1 entPhysicalName.102 = Internal POE Bay 0 entPhysicalName.1000 = module 0 entPhysicalName.1001 = subslot 0/1 entPhysicalName.1002 = subslot 0/2 entPhysicalName.1003 = subslot 0/3 entPhysicalName.1004 = subslot 0/4 entPhysicalName.1015 = NIM subslot 0/0 entPhysicalName.1016 = GigabitEthernet0/0/0 entPhysicalName.1017 = GigabitEthernet0/0/1 entPhysicalName.1018 = GigabitEthernet0/0/2 entPhysicalName.1019 = GigabitEthernet0/0/3 entPhysicalName.1046 = subslot 0/0 transceiver container 0 entPhysicalName.1056 = subslot 0/0 transceiver container 1 entPhysicalName.1066 = subslot 0/0 transceiver container 2 entPhysicalName.1076 = subslot 0/0 transceiver container 3 entPhysicalName.3000 = module 1 entPhysicalName.3001 = slot 1 entPhysicalName.5000 = module 2 entPhysicalName.5001 = slot 2 entPhysicalName.7000 = module R0 entPhysicalName.7001 = Temp: Inlet 1 R0/0 entPhysicalName.7002 = Temp: Inlet 2 R0/1 entPhysicalName.7003 = Temp: Outlet 1 R0/2 entPhysicalName.7004 = Temp: Outlet 2 R0/3 entPhysicalName.7005 = Temp: core-A R0/4 entPhysicalName.7006 = Temp: core-B R0/5 entPhysicalName.7007 = Temp: core-C R0/6 entPhysicalName.7008 = V: 12v R0/7 entPhysicalName.7009 = V: 5v R0/8 entPhysicalName.7010 = V: 3.3v R0/9 entPhysicalName.7011 = V: 3.0v R0/10 entPhysicalName.7012 = V: 2.5v R0/11 entPhysicalName.7013 = V: 1.05v R0/12 entPhysicalName.7014 = V: 1.8v R0/13 entPhysicalName.7015 = V: 1.2v R0/14 entPhysicalName.7016 = V: Vcore-C R0/15 entPhysicalName.7017 = V: 1.1v R0/16 entPhysicalName.7018 = V: 1.0v R0/17 entPhysicalName.7019 = V: 1.8v-A R0/18 entPhysicalName.7020 = V: 1.5v-A R0/19 entPhysicalName.7021 = V: 1.5v-C1 R0/20 entPhysicalName.7022 = V: 1.5v-B R0/21 entPhysicalName.7023 = V: Vcore-A R0/22 entPhysicalName.7024 = V: 1.5v-C2 R0/23 entPhysicalName.7025 = V: Vcore-B1 R0/24 entPhysicalName.7026 = V: Vcore-B2 R0/25 entPhysicalName.7027 = V: 0.75v-B R0/26 entPhysicalName.7028 = V: 0.75v-C R0/27 entPhysicalName.7029 = I: 12v R0/28 entPhysicalName.7030 = P: pwr R0/29 entPhysicalName.7035 = cpu R0/0 entPhysicalName.7036 = usb R0/0 entPhysicalName.7038 = usb R0/1 entPhysicalName.7040 = NME R0 entPhysicalName.9000 = module F0 entPhysicalName.9001 = qfp F0/0 entPhysicalModelNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalModelName[0m] entPhysicalModelName.1 = ISR4451-X/K9 entPhysicalModelName.2 = entPhysicalModelName.3 = PWR-4450-AC entPhysicalModelName.4 = entPhysicalModelName.5 = entPhysicalModelName.6 = entPhysicalModelName.7 = entPhysicalModelName.8 = entPhysicalModelName.9 = entPhysicalModelName.10 = entPhysicalModelName.11 = entPhysicalModelName.12 = entPhysicalModelName.13 = entPhysicalModelName.14 = entPhysicalModelName.22 = entPhysicalModelName.42 = entPhysicalModelName.43 = ACS-4450-FANASSY entPhysicalModelName.44 = entPhysicalModelName.45 = entPhysicalModelName.46 = entPhysicalModelName.47 = entPhysicalModelName.48 = entPhysicalModelName.54 = entPhysicalModelName.55 = entPhysicalModelName.56 = entPhysicalModelName.57 = entPhysicalModelName.62 = entPhysicalModelName.82 = entPhysicalModelName.102 = entPhysicalModelName.1000 = ISR4451-X/K9 entPhysicalModelName.1001 = entPhysicalModelName.1002 = entPhysicalModelName.1003 = entPhysicalModelName.1004 = entPhysicalModelName.1015 = ISR4451-X-4x1GE entPhysicalModelName.1016 = entPhysicalModelName.1017 = entPhysicalModelName.1018 = entPhysicalModelName.1019 = entPhysicalModelName.1046 = entPhysicalModelName.1056 = entPhysicalModelName.1066 = entPhysicalModelName.1076 = entPhysicalModelName.3000 = ISR4451-X/K9 entPhysicalModelName.3001 = entPhysicalModelName.5000 = ISR4451-X/K9 entPhysicalModelName.5001 = entPhysicalModelName.7000 = ISR4451-X/K9 entPhysicalModelName.7001 = entPhysicalModelName.7002 = entPhysicalModelName.7003 = entPhysicalModelName.7004 = entPhysicalModelName.7005 = entPhysicalModelName.7006 = entPhysicalModelName.7007 = entPhysicalModelName.7008 = entPhysicalModelName.7009 = entPhysicalModelName.7010 = entPhysicalModelName.7011 = entPhysicalModelName.7012 = entPhysicalModelName.7013 = entPhysicalModelName.7014 = entPhysicalModelName.7015 = entPhysicalModelName.7016 = entPhysicalModelName.7017 = entPhysicalModelName.7018 = entPhysicalModelName.7019 = entPhysicalModelName.7020 = entPhysicalModelName.7021 = entPhysicalModelName.7022 = entPhysicalModelName.7023 = entPhysicalModelName.7024 = entPhysicalModelName.7025 = entPhysicalModelName.7026 = entPhysicalModelName.7027 = entPhysicalModelName.7028 = entPhysicalModelName.7029 = entPhysicalModelName.7030 = entPhysicalModelName.7035 = entPhysicalModelName.7036 = entPhysicalModelName.7038 = entPhysicalModelName.7040 = entPhysicalModelName.9000 = ISR4451-X/K9 entPhysicalModelName.9001 = 7035 cpu R0/0 - |- ipv4 | |-1: RP RIB SQL[[1;33mSELECT COUNT(*) from `cef_switching` WHERE device_id = ? AND entPhysicalIndex = ? AND afi=? AND cef_index=? [0;33m[7,7035,"ipv4",1][0m 0.36ms] | |-2: RP LES SQL[[1;33mSELECT COUNT(*) from `cef_switching` WHERE device_id = ? AND entPhysicalIndex = ? AND afi=? AND cef_index=? [0;33m[7,7035,"ipv4",2][0m 0.19ms] |- ipv6 | |-1: RP LES SQL[[1;33mSELECT COUNT(*) from `cef_switching` WHERE device_id = ? AND entPhysicalIndex = ? AND afi=? AND cef_index=? [0;33m[7,7035,"ipv6",1][0m 0.16ms] >> Runtime for discovery module 'cisco-cef': 0.0630 seconds with 148576 bytes >> SNMP: [3/0.05s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-cef #### Modules status: Global- OS+ Device #### Load disco module cisco-sla #### >> Runtime for discovery module 'cisco-sla': 0.0000 seconds with 1616 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-sla #### Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS+ Device #### Load disco module cisco-otv #### SQL[[1;33mSELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = ? AND `type` = ? ) [0;33m[7,"Cisco-OTV"][0m 0.34ms] Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.2.1.1[0m] .*.*.8*.1 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.3.1.1[0m] .*.*.8*.1 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.810.1.3.1.1.4[0m] .*.*.8*.1.4 No Such Object available on this agent at this OID Adjacency: Unknown () - Endpoint: Index: UID: adjacency-- Status: 1 Message: Adjacency is Down Endpoint: Endpoint: 0 UID: endpoint-0 Type: endpoint ..SQL[[1;33mSELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = ? ) [0;33m[7][0m 0.35ms] Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 >> Runtime for discovery module 'Cisco-OTV': 0.0340 seconds with 55336 bytes >> SNMP: [3/0.03s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module Cisco-OTV #### Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 2 ipAdEntIfIndex.* 4 ipAdEntIfIndex.* 1 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.63.192.158.1[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[7,"2"][0m 0.34ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,"2"][0m 0.17ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.1\/27"][0m 0.18ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"63.192.158.1\/27"][0m 0.48ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.1\/27"][0m 0.11ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["63.192.158.1",27,234][0m 0.1ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"63.192.158.1",27,234][0m 0.39ms] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.63.192.158.33[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[7,"4"][0m 0.21ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,"4"][0m 0.12ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.33\/27"][0m 0.12ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"63.192.158.33\/27"][0m 0.35ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.33\/27"][0m 0.12ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["63.192.158.33",27,236][0m 0.12ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"63.192.158.33",27,236][0m 0.21ms] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAdEntNetMask.63.192.158.66[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[7,"1"][0m 0.28ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,"1"][0m 0.17ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.66\/29"][0m 0.15ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"63.192.158.66\/29"][0m 0.38ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["63.192.158.66\/29"][0m 0.12ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["63.192.158.66",29,233][0m 0.11ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"63.192.158.66",29,233][0m 0.22ms] .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[7][0m 0.14ms] >> Runtime for discovery module 'ipv4-addresses': 0.0540 seconds with 38584 bytes >> SNMP: [4/0.05s] MySQL: [7/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[7][0m 0.44ms] >> Runtime for discovery module 'ipv6-addresses': 0.0200 seconds with 3352 bytes >> SNMP: [2/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### CISCO-ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entPhysicalClassSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalClass[0m] entPhysicalClass.1 = chassis entPhysicalClass.2 = container entPhysicalClass.3 = powerSupply entPhysicalClass.4 = sensor entPhysicalClass.5 = sensor entPhysicalClass.6 = sensor entPhysicalClass.7 = sensor entPhysicalClass.8 = sensor entPhysicalClass.9 = sensor entPhysicalClass.10 = sensor entPhysicalClass.11 = sensor entPhysicalClass.12 = sensor entPhysicalClass.13 = powerSupply entPhysicalClass.14 = fan entPhysicalClass.22 = container entPhysicalClass.42 = container entPhysicalClass.43 = fan entPhysicalClass.44 = sensor entPhysicalClass.45 = sensor entPhysicalClass.46 = sensor entPhysicalClass.47 = sensor entPhysicalClass.48 = sensor entPhysicalClass.54 = fan entPhysicalClass.55 = fan entPhysicalClass.56 = fan entPhysicalClass.57 = fan entPhysicalClass.62 = container entPhysicalClass.82 = container entPhysicalClass.102 = container entPhysicalClass.1000 = module entPhysicalClass.1001 = container entPhysicalClass.1002 = container entPhysicalClass.1003 = container entPhysicalClass.1004 = container entPhysicalClass.1015 = module entPhysicalClass.1016 = port entPhysicalClass.1017 = port entPhysicalClass.1018 = port entPhysicalClass.1019 = port entPhysicalClass.1046 = container entPhysicalClass.1056 = container entPhysicalClass.1066 = container entPhysicalClass.1076 = container entPhysicalClass.3000 = module entPhysicalClass.3001 = container entPhysicalClass.5000 = module entPhysicalClass.5001 = container entPhysicalClass.7000 = module entPhysicalClass.7001 = sensor entPhysicalClass.7002 = sensor entPhysicalClass.7003 = sensor entPhysicalClass.7004 = sensor entPhysicalClass.7005 = sensor entPhysicalClass.7006 = sensor entPhysicalClass.7007 = sensor entPhysicalClass.7008 = sensor entPhysicalClass.7009 = sensor entPhysicalClass.7010 = sensor entPhysicalClass.7011 = sensor entPhysicalClass.7012 = sensor entPhysicalClass.7013 = sensor entPhysicalClass.7014 = sensor entPhysicalClass.7015 = sensor entPhysicalClass.7016 = sensor entPhysicalClass.7017 = sensor entPhysicalClass.7018 = sensor entPhysicalClass.7019 = sensor entPhysicalClass.7020 = sensor entPhysicalClass.7021 = sensor entPhysicalClass.7022 = sensor entPhysicalClass.7023 = sensor entPhysicalClass.7024 = sensor entPhysicalClass.7025 = sensor entPhysicalClass.7026 = sensor entPhysicalClass.7027 = sensor entPhysicalClass.7028 = sensor entPhysicalClass.7029 = sensor entPhysicalClass.7030 = sensor entPhysicalClass.7035 = cpu entPhysicalClass.7036 = container entPhysicalClass.7038 = container entPhysicalClass.7040 = port entPhysicalClass.9000 = module entPhysicalClass.9001 = cpu entPhysicalContainedInSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalContainedIn[0m] entPhysicalContainedIn.1 = 0 entPhysicalContainedIn.2 = 1 entPhysicalContainedIn.3 = 2 entPhysicalContainedIn.4 = 3 entPhysicalContainedIn.5 = 3 entPhysicalContainedIn.6 = 3 entPhysicalContainedIn.7 = 3 entPhysicalContainedIn.8 = 3 entPhysicalContainedIn.9 = 3 entPhysicalContainedIn.10 = 3 entPhysicalContainedIn.11 = 3 entPhysicalContainedIn.12 = 3 entPhysicalContainedIn.13 = 3 entPhysicalContainedIn.14 = 3 entPhysicalContainedIn.22 = 1 entPhysicalContainedIn.42 = 1 entPhysicalContainedIn.43 = 42 entPhysicalContainedIn.44 = 43 entPhysicalContainedIn.45 = 43 entPhysicalContainedIn.46 = 43 entPhysicalContainedIn.47 = 43 entPhysicalContainedIn.48 = 43 entPhysicalContainedIn.54 = 43 entPhysicalContainedIn.55 = 43 entPhysicalContainedIn.56 = 43 entPhysicalContainedIn.57 = 43 entPhysicalContainedIn.62 = 1 entPhysicalContainedIn.82 = 1 entPhysicalContainedIn.102 = 1 entPhysicalContainedIn.1000 = 1 entPhysicalContainedIn.1001 = 1000 entPhysicalContainedIn.1002 = 1000 entPhysicalContainedIn.1003 = 1000 entPhysicalContainedIn.1004 = 1000 entPhysicalContainedIn.1015 = 1000 entPhysicalContainedIn.1016 = 1015 entPhysicalContainedIn.1017 = 1015 entPhysicalContainedIn.1018 = 1015 entPhysicalContainedIn.1019 = 1015 entPhysicalContainedIn.1046 = 1015 entPhysicalContainedIn.1056 = 1015 entPhysicalContainedIn.1066 = 1015 entPhysicalContainedIn.1076 = 1015 entPhysicalContainedIn.3000 = 1 entPhysicalContainedIn.3001 = 3000 entPhysicalContainedIn.5000 = 1 entPhysicalContainedIn.5001 = 5000 entPhysicalContainedIn.7000 = 1 entPhysicalContainedIn.7001 = 7000 entPhysicalContainedIn.7002 = 7000 entPhysicalContainedIn.7003 = 7000 entPhysicalContainedIn.7004 = 7000 entPhysicalContainedIn.7005 = 7000 entPhysicalContainedIn.7006 = 7000 entPhysicalContainedIn.7007 = 7000 entPhysicalContainedIn.7008 = 7000 entPhysicalContainedIn.7009 = 7000 entPhysicalContainedIn.7010 = 7000 entPhysicalContainedIn.7011 = 7000 entPhysicalContainedIn.7012 = 7000 entPhysicalContainedIn.7013 = 7000 entPhysicalContainedIn.7014 = 7000 entPhysicalContainedIn.7015 = 7000 entPhysicalContainedIn.7016 = 7000 entPhysicalContainedIn.7017 = 7000 entPhysicalContainedIn.7018 = 7000 entPhysicalContainedIn.7019 = 7000 entPhysicalContainedIn.7020 = 7000 entPhysicalContainedIn.7021 = 7000 entPhysicalContainedIn.7022 = 7000 entPhysicalContainedIn.7023 = 7000 entPhysicalContainedIn.7024 = 7000 entPhysicalContainedIn.7025 = 7000 entPhysicalContainedIn.7026 = 7000 entPhysicalContainedIn.7027 = 7000 entPhysicalContainedIn.7028 = 7000 entPhysicalContainedIn.7029 = 7000 entPhysicalContainedIn.7030 = 7000 entPhysicalContainedIn.7035 = 7000 entPhysicalContainedIn.7036 = 7000 entPhysicalContainedIn.7038 = 7000 entPhysicalContainedIn.7040 = 7000 entPhysicalContainedIn.9000 = 1 entPhysicalContainedIn.9001 = 9000 entPhysicalParentRelPosSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalParentRelPos[0m] entPhysicalParentRelPos.1 = -1 entPhysicalParentRelPos.2 = 9 entPhysicalParentRelPos.3 = 0 entPhysicalParentRelPos.4 = 0 entPhysicalParentRelPos.5 = 1 entPhysicalParentRelPos.6 = 2 entPhysicalParentRelPos.7 = 3 entPhysicalParentRelPos.8 = 4 entPhysicalParentRelPos.9 = 5 entPhysicalParentRelPos.10 = 6 entPhysicalParentRelPos.11 = 7 entPhysicalParentRelPos.12 = 8 entPhysicalParentRelPos.13 = 0 entPhysicalParentRelPos.14 = 0 entPhysicalParentRelPos.22 = 10 entPhysicalParentRelPos.42 = 11 entPhysicalParentRelPos.43 = 0 entPhysicalParentRelPos.44 = 0 entPhysicalParentRelPos.45 = 1 entPhysicalParentRelPos.46 = 2 entPhysicalParentRelPos.47 = 3 entPhysicalParentRelPos.48 = 4 entPhysicalParentRelPos.54 = 0 entPhysicalParentRelPos.55 = 1 entPhysicalParentRelPos.56 = 2 entPhysicalParentRelPos.57 = 3 entPhysicalParentRelPos.62 = 12 entPhysicalParentRelPos.82 = 13 entPhysicalParentRelPos.102 = 14 entPhysicalParentRelPos.1000 = 0 entPhysicalParentRelPos.1001 = 1 entPhysicalParentRelPos.1002 = 2 entPhysicalParentRelPos.1003 = 3 entPhysicalParentRelPos.1004 = 4 entPhysicalParentRelPos.1015 = 0 entPhysicalParentRelPos.1016 = 0 entPhysicalParentRelPos.1017 = 1 entPhysicalParentRelPos.1018 = 2 entPhysicalParentRelPos.1019 = 3 entPhysicalParentRelPos.1046 = 0 entPhysicalParentRelPos.1056 = 1 entPhysicalParentRelPos.1066 = 2 entPhysicalParentRelPos.1076 = 3 entPhysicalParentRelPos.3000 = 1 entPhysicalParentRelPos.3001 = 0 entPhysicalParentRelPos.5000 = 2 entPhysicalParentRelPos.5001 = 0 entPhysicalParentRelPos.7000 = 6 entPhysicalParentRelPos.7001 = 0 entPhysicalParentRelPos.7002 = 1 entPhysicalParentRelPos.7003 = 2 entPhysicalParentRelPos.7004 = 3 entPhysicalParentRelPos.7005 = 4 entPhysicalParentRelPos.7006 = 5 entPhysicalParentRelPos.7007 = 6 entPhysicalParentRelPos.7008 = 7 entPhysicalParentRelPos.7009 = 8 entPhysicalParentRelPos.7010 = 9 entPhysicalParentRelPos.7011 = 10 entPhysicalParentRelPos.7012 = 11 entPhysicalParentRelPos.7013 = 12 entPhysicalParentRelPos.7014 = 13 entPhysicalParentRelPos.7015 = 14 entPhysicalParentRelPos.7016 = 15 entPhysicalParentRelPos.7017 = 16 entPhysicalParentRelPos.7018 = 17 entPhysicalParentRelPos.7019 = 18 entPhysicalParentRelPos.7020 = 19 entPhysicalParentRelPos.7021 = 20 entPhysicalParentRelPos.7022 = 21 entPhysicalParentRelPos.7023 = 22 entPhysicalParentRelPos.7024 = 23 entPhysicalParentRelPos.7025 = 24 entPhysicalParentRelPos.7026 = 25 entPhysicalParentRelPos.7027 = 26 entPhysicalParentRelPos.7028 = 27 entPhysicalParentRelPos.7029 = 28 entPhysicalParentRelPos.7030 = 29 entPhysicalParentRelPos.7035 = 0 entPhysicalParentRelPos.7036 = 0 entPhysicalParentRelPos.7038 = 1 entPhysicalParentRelPos.7040 = 2 entPhysicalParentRelPos.9000 = 8 entPhysicalParentRelPos.9001 = 0 entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier.1016.0 = ifIndex.1 entAliasMappingIdentifier.1017.0 = ifIndex.2 entAliasMappingIdentifier.1018.0 = ifIndex.3 entAliasMappingIdentifier.1019.0 = ifIndex.4 entAliasMappingIdentifier.7040.0 = ifIndex.5 entSensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorType[0m] entSensorType.4 = celsius entSensorType.5 = celsius entSensorType.6 = celsius entSensorType.7 = voltsDC entSensorType.8 = amperes entSensorType.9 = amperes entSensorType.10 = watts entSensorType.11 = watts entSensorType.12 = rpm entSensorType.44 = rpm entSensorType.45 = rpm entSensorType.46 = rpm entSensorType.47 = rpm entSensorType.48 = watts entSensorType.7001 = celsius entSensorType.7002 = celsius entSensorType.7003 = celsius entSensorType.7004 = celsius entSensorType.7005 = celsius entSensorType.7006 = celsius entSensorType.7007 = celsius entSensorType.7008 = voltsDC entSensorType.7009 = voltsDC entSensorType.7010 = voltsDC entSensorType.7011 = voltsDC entSensorType.7012 = voltsDC entSensorType.7013 = voltsDC entSensorType.7014 = voltsDC entSensorType.7015 = voltsDC entSensorType.7016 = voltsDC entSensorType.7017 = voltsDC entSensorType.7018 = voltsDC entSensorType.7019 = voltsDC entSensorType.7020 = voltsDC entSensorType.7021 = voltsDC entSensorType.7022 = voltsDC entSensorType.7023 = voltsDC entSensorType.7024 = voltsDC entSensorType.7025 = voltsDC entSensorType.7026 = voltsDC entSensorType.7027 = voltsDC entSensorType.7028 = voltsDC entSensorType.7029 = amperes entSensorType.7030 = watts entSensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorScale[0m] entSensorScale.4 = units entSensorScale.5 = units entSensorScale.6 = units entSensorScale.7 = milli entSensorScale.8 = units entSensorScale.9 = units entSensorScale.10 = units entSensorScale.11 = units entSensorScale.12 = units entSensorScale.44 = units entSensorScale.45 = units entSensorScale.46 = units entSensorScale.47 = units entSensorScale.48 = units entSensorScale.7001 = units entSensorScale.7002 = units entSensorScale.7003 = units entSensorScale.7004 = units entSensorScale.7005 = units entSensorScale.7006 = units entSensorScale.7007 = units entSensorScale.7008 = milli entSensorScale.7009 = milli entSensorScale.7010 = milli entSensorScale.7011 = milli entSensorScale.7012 = milli entSensorScale.7013 = milli entSensorScale.7014 = milli entSensorScale.7015 = milli entSensorScale.7016 = milli entSensorScale.7017 = milli entSensorScale.7018 = milli entSensorScale.7019 = milli entSensorScale.7020 = milli entSensorScale.7021 = milli entSensorScale.7022 = milli entSensorScale.7023 = milli entSensorScale.7024 = milli entSensorScale.7025 = milli entSensorScale.7026 = milli entSensorScale.7027 = milli entSensorScale.7028 = milli entSensorScale.7029 = units entSensorScale.7030 = units entSensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorValue[0m] entSensorValue.4 = 35 entSensorValue.5 = 29 entSensorValue.6 = 38 entSensorValue.7 = 12447 entSensorValue.8 = 1 entSensorValue.9 = 5 entSensorValue.10 = 72 entSensorValue.11 = 61 entSensorValue.12 = 2924 entSensorValue.44 = 4236 entSensorValue.45 = 4458 entSensorValue.46 = 4319 entSensorValue.47 = 4384 entSensorValue.48 = 5 entSensorValue.7001 = 19 entSensorValue.7002 = 18 entSensorValue.7003 = 25 entSensorValue.7004 = 28 entSensorValue.7005 = 39 entSensorValue.7006 = 33 entSensorValue.7007 = 36 entSensorValue.7008 = 12450 entSensorValue.7009 = 5104 entSensorValue.7010 = 3331 entSensorValue.7011 = 3006 entSensorValue.7012 = 2436 entSensorValue.7013 = 1044 entSensorValue.7014 = 1808 entSensorValue.7015 = 1228 entSensorValue.7016 = 1155 entSensorValue.7017 = 1112 entSensorValue.7018 = 1023 entSensorValue.7019 = 1787 entSensorValue.7020 = 1513 entSensorValue.7021 = 1526 entSensorValue.7022 = 1513 entSensorValue.7023 = 1002 entSensorValue.7024 = 1511 entSensorValue.7025 = 915 entSensorValue.7026 = 909 entSensorValue.7027 = 759 entSensorValue.7028 = 770 entSensorValue.7029 = 5 entSensorValue.7030 = 56 entSensorMeasuredEntitySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorMeasuredEntity[0m] entSensorMeasuredEntity.4 = 3 entSensorMeasuredEntity.5 = 3 entSensorMeasuredEntity.6 = 3 entSensorMeasuredEntity.7 = 3 entSensorMeasuredEntity.8 = 3 entSensorMeasuredEntity.9 = 3 entSensorMeasuredEntity.10 = 3 entSensorMeasuredEntity.11 = 3 entSensorMeasuredEntity.12 = 3 entSensorMeasuredEntity.44 = 43 entSensorMeasuredEntity.45 = 43 entSensorMeasuredEntity.46 = 43 entSensorMeasuredEntity.47 = 43 entSensorMeasuredEntity.48 = 43 entSensorMeasuredEntity.7001 = 7000 entSensorMeasuredEntity.7002 = 7000 entSensorMeasuredEntity.7003 = 7000 entSensorMeasuredEntity.7004 = 7000 entSensorMeasuredEntity.7005 = 7000 entSensorMeasuredEntity.7006 = 7000 entSensorMeasuredEntity.7007 = 7000 entSensorMeasuredEntity.7008 = 7000 entSensorMeasuredEntity.7009 = 7000 entSensorMeasuredEntity.7010 = 7000 entSensorMeasuredEntity.7011 = 7000 entSensorMeasuredEntity.7012 = 7000 entSensorMeasuredEntity.7013 = 7000 entSensorMeasuredEntity.7014 = 7000 entSensorMeasuredEntity.7015 = 7000 entSensorMeasuredEntity.7016 = 7000 entSensorMeasuredEntity.7017 = 7000 entSensorMeasuredEntity.7018 = 7000 entSensorMeasuredEntity.7019 = 7000 entSensorMeasuredEntity.7020 = 7000 entSensorMeasuredEntity.7021 = 7000 entSensorMeasuredEntity.7022 = 7000 entSensorMeasuredEntity.7023 = 7000 entSensorMeasuredEntity.7024 = 7000 entSensorMeasuredEntity.7025 = 7000 entSensorMeasuredEntity.7026 = 7000 entSensorMeasuredEntity.7027 = 7000 entSensorMeasuredEntity.7028 = 7000 entSensorMeasuredEntity.7029 = 7000 entSensorMeasuredEntity.7030 = 7000 entSensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorPrecision[0m] entSensorPrecision.4 = 0 entSensorPrecision.5 = 0 entSensorPrecision.6 = 0 entSensorPrecision.7 = 0 entSensorPrecision.8 = 0 entSensorPrecision.9 = 0 entSensorPrecision.10 = 0 entSensorPrecision.11 = 0 entSensorPrecision.12 = 0 entSensorPrecision.44 = 0 entSensorPrecision.45 = 0 entSensorPrecision.46 = 0 entSensorPrecision.47 = 0 entSensorPrecision.48 = 0 entSensorPrecision.7001 = 0 entSensorPrecision.7002 = 0 entSensorPrecision.7003 = 0 entSensorPrecision.7004 = 0 entSensorPrecision.7005 = 0 entSensorPrecision.7006 = 0 entSensorPrecision.7007 = 0 entSensorPrecision.7008 = 0 entSensorPrecision.7009 = 0 entSensorPrecision.7010 = 0 entSensorPrecision.7011 = 0 entSensorPrecision.7012 = 0 entSensorPrecision.7013 = 0 entSensorPrecision.7014 = 0 entSensorPrecision.7015 = 0 entSensorPrecision.7016 = 0 entSensorPrecision.7017 = 0 entSensorPrecision.7018 = 0 entSensorPrecision.7019 = 0 entSensorPrecision.7020 = 0 entSensorPrecision.7021 = 0 entSensorPrecision.7022 = 0 entSensorPrecision.7023 = 0 entSensorPrecision.7024 = 0 entSensorPrecision.7025 = 0 entSensorPrecision.7026 = 0 entSensorPrecision.7027 = 0 entSensorPrecision.7028 = 0 entSensorPrecision.7029 = 0 entSensorPrecision.7030 = 0 entSensorThresholdSeveritySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdSeverity[0m] entSensorThresholdSeverity.7.1 = major entSensorThresholdSeverity.7.2 = major entSensorThresholdSeverity.44.1 = major entSensorThresholdSeverity.45.1 = major entSensorThresholdSeverity.46.1 = major entSensorThresholdSeverity.47.1 = major entSensorThresholdSeverity.7001.1 = major entSensorThresholdSeverity.7001.2 = major entSensorThresholdSeverity.7001.3 = critical entSensorThresholdSeverity.7003.1 = major entSensorThresholdSeverity.7003.2 = major entSensorThresholdSeverity.7003.3 = critical entSensorThresholdSeverity.7004.1 = major entSensorThresholdSeverity.7004.2 = major entSensorThresholdSeverity.7004.3 = critical entSensorThresholdSeverity.7005.1 = major entSensorThresholdSeverity.7005.2 = major entSensorThresholdSeverity.7005.3 = critical entSensorThresholdSeverity.7006.1 = major entSensorThresholdSeverity.7006.2 = major entSensorThresholdSeverity.7006.3 = critical entSensorThresholdSeverity.7007.1 = major entSensorThresholdSeverity.7007.2 = major entSensorThresholdSeverity.7007.3 = critical entSensorThresholdSeverity.7008.1 = major entSensorThresholdSeverity.7008.2 = major entSensorThresholdSeverity.7009.1 = major entSensorThresholdSeverity.7009.2 = major entSensorThresholdSeverity.7010.1 = major entSensorThresholdSeverity.7010.2 = major entSensorThresholdSeverity.7011.1 = major entSensorThresholdSeverity.7011.2 = major entSensorThresholdSeverity.7012.1 = major entSensorThresholdSeverity.7012.2 = major entSensorThresholdSeverity.7013.1 = major entSensorThresholdSeverity.7013.2 = major entSensorThresholdSeverity.7014.1 = major entSensorThresholdSeverity.7014.2 = major entSensorThresholdSeverity.7015.1 = major entSensorThresholdSeverity.7015.2 = major entSensorThresholdSeverity.7017.1 = major entSensorThresholdSeverity.7017.2 = major entSensorThresholdSeverity.7018.1 = major entSensorThresholdSeverity.7018.2 = major entSensorThresholdSeverity.7019.1 = major entSensorThresholdSeverity.7019.2 = major entSensorThresholdSeverity.7020.1 = major entSensorThresholdSeverity.7020.2 = major entSensorThresholdSeverity.7021.1 = major entSensorThresholdSeverity.7021.2 = major entSensorThresholdSeverity.7022.1 = major entSensorThresholdSeverity.7022.2 = major entSensorThresholdSeverity.7024.1 = major entSensorThresholdSeverity.7024.2 = major entSensorThresholdSeverity.7027.1 = major entSensorThresholdSeverity.7027.2 = major entSensorThresholdSeverity.7028.1 = major entSensorThresholdSeverity.7028.2 = major entSensorThresholdRelationSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdRelation[0m] entSensorThresholdRelation.7.1 = lessOrEqual entSensorThresholdRelation.7.2 = greaterOrEqual entSensorThresholdRelation.44.1 = lessOrEqual entSensorThresholdRelation.45.1 = lessOrEqual entSensorThresholdRelation.46.1 = lessOrEqual entSensorThresholdRelation.47.1 = lessOrEqual entSensorThresholdRelation.7001.1 = lessOrEqual entSensorThresholdRelation.7001.2 = greaterOrEqual entSensorThresholdRelation.7001.3 = greaterOrEqual entSensorThresholdRelation.7003.1 = lessOrEqual entSensorThresholdRelation.7003.2 = greaterOrEqual entSensorThresholdRelation.7003.3 = greaterOrEqual entSensorThresholdRelation.7004.1 = lessOrEqual entSensorThresholdRelation.7004.2 = greaterOrEqual entSensorThresholdRelation.7004.3 = greaterOrEqual entSensorThresholdRelation.7005.1 = lessOrEqual entSensorThresholdRelation.7005.2 = greaterOrEqual entSensorThresholdRelation.7005.3 = greaterOrEqual entSensorThresholdRelation.7006.1 = lessOrEqual entSensorThresholdRelation.7006.2 = greaterOrEqual entSensorThresholdRelation.7006.3 = greaterOrEqual entSensorThresholdRelation.7007.1 = lessOrEqual entSensorThresholdRelation.7007.2 = greaterOrEqual entSensorThresholdRelation.7007.3 = greaterOrEqual entSensorThresholdRelation.7008.1 = lessOrEqual entSensorThresholdRelation.7008.2 = greaterOrEqual entSensorThresholdRelation.7009.1 = lessOrEqual entSensorThresholdRelation.7009.2 = greaterOrEqual entSensorThresholdRelation.7010.1 = lessOrEqual entSensorThresholdRelation.7010.2 = greaterOrEqual entSensorThresholdRelation.7011.1 = lessOrEqual entSensorThresholdRelation.7011.2 = greaterOrEqual entSensorThresholdRelation.7012.1 = lessOrEqual entSensorThresholdRelation.7012.2 = greaterOrEqual entSensorThresholdRelation.7013.1 = lessOrEqual entSensorThresholdRelation.7013.2 = greaterOrEqual entSensorThresholdRelation.7014.1 = lessOrEqual entSensorThresholdRelation.7014.2 = greaterOrEqual entSensorThresholdRelation.7015.1 = lessOrEqual entSensorThresholdRelation.7015.2 = greaterOrEqual entSensorThresholdRelation.7017.1 = lessOrEqual entSensorThresholdRelation.7017.2 = greaterOrEqual entSensorThresholdRelation.7018.1 = lessOrEqual entSensorThresholdRelation.7018.2 = greaterOrEqual entSensorThresholdRelation.7019.1 = lessOrEqual entSensorThresholdRelation.7019.2 = greaterOrEqual entSensorThresholdRelation.7020.1 = lessOrEqual entSensorThresholdRelation.7020.2 = greaterOrEqual entSensorThresholdRelation.7021.1 = lessOrEqual entSensorThresholdRelation.7021.2 = greaterOrEqual entSensorThresholdRelation.7022.1 = lessOrEqual entSensorThresholdRelation.7022.2 = greaterOrEqual entSensorThresholdRelation.7024.1 = lessOrEqual entSensorThresholdRelation.7024.2 = greaterOrEqual entSensorThresholdRelation.7027.1 = lessOrEqual entSensorThresholdRelation.7027.2 = greaterOrEqual entSensorThresholdRelation.7028.1 = lessOrEqual entSensorThresholdRelation.7028.2 = greaterOrEqual entSensorThresholdValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entSensorThresholdValue[0m] entSensorThresholdValue.7.1 = 10800 entSensorThresholdValue.7.2 = 13100 entSensorThresholdValue.44.1 = 2000 entSensorThresholdValue.45.1 = 2000 entSensorThresholdValue.46.1 = 2000 entSensorThresholdValue.47.1 = 2000 entSensorThresholdValue.7001.1 = -3 entSensorThresholdValue.7001.2 = 43 entSensorThresholdValue.7001.3 = 48 entSensorThresholdValue.7003.1 = -3 entSensorThresholdValue.7003.2 = 76 entSensorThresholdValue.7003.3 = 81 entSensorThresholdValue.7004.1 = -3 entSensorThresholdValue.7004.2 = 76 entSensorThresholdValue.7004.3 = 81 entSensorThresholdValue.7005.1 = -3 entSensorThresholdValue.7005.2 = 86 entSensorThresholdValue.7005.3 = 91 entSensorThresholdValue.7006.1 = -3 entSensorThresholdValue.7006.2 = 96 entSensorThresholdValue.7006.3 = 101 entSensorThresholdValue.7007.1 = -3 entSensorThresholdValue.7007.2 = 96 entSensorThresholdValue.7007.3 = 101 entSensorThresholdValue.7008.1 = 10800 entSensorThresholdValue.7008.2 = 13200 entSensorThresholdValue.7009.1 = 4500 entSensorThresholdValue.7009.2 = 5500 entSensorThresholdValue.7010.1 = 2970 entSensorThresholdValue.7010.2 = 3630 entSensorThresholdValue.7011.1 = 2700 entSensorThresholdValue.7011.2 = 3300 entSensorThresholdValue.7012.1 = 2250 entSensorThresholdValue.7012.2 = 2750 entSensorThresholdValue.7013.1 = 945 entSensorThresholdValue.7013.2 = 1155 entSensorThresholdValue.7014.1 = 1620 entSensorThresholdValue.7014.2 = 1980 entSensorThresholdValue.7015.1 = 1080 entSensorThresholdValue.7015.2 = 1320 entSensorThresholdValue.7017.1 = 1010 entSensorThresholdValue.7017.2 = 1190 entSensorThresholdValue.7018.1 = 900 entSensorThresholdValue.7018.2 = 1100 entSensorThresholdValue.7019.1 = 1620 entSensorThresholdValue.7019.2 = 1980 entSensorThresholdValue.7020.1 = 1350 entSensorThresholdValue.7020.2 = 1650 entSensorThresholdValue.7021.1 = 1350 entSensorThresholdValue.7021.2 = 1650 entSensorThresholdValue.7022.1 = 1350 entSensorThresholdValue.7022.2 = 1650 entSensorThresholdValue.7024.1 = 1350 entSensorThresholdValue.7024.2 = 1650 entSensorThresholdValue.7027.1 = 675 entSensorThresholdValue.7027.2 = 825 entSensorThresholdValue.7028.1 = 675 entSensorThresholdValue.7028.2 = 825 Array ( [4] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 35 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [5] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 29 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [6] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 38 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [7] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 12447 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [8] => Array ( [entSensorType] => amperes [entSensorScale] => units [entSensorValue] => 1 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [9] => Array ( [entSensorType] => amperes [entSensorScale] => units [entSensorValue] => 5 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [10] => Array ( [entSensorType] => watts [entSensorScale] => units [entSensorValue] => 72 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [11] => Array ( [entSensorType] => watts [entSensorScale] => units [entSensorValue] => 61 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [12] => Array ( [entSensorType] => rpm [entSensorScale] => units [entSensorValue] => 2924 [entSensorMeasuredEntity] => 3 [entSensorPrecision] => 0 ) [44] => Array ( [entSensorType] => rpm [entSensorScale] => units [entSensorValue] => 4236 [entSensorMeasuredEntity] => 43 [entSensorPrecision] => 0 ) [45] => Array ( [entSensorType] => rpm [entSensorScale] => units [entSensorValue] => 4458 [entSensorMeasuredEntity] => 43 [entSensorPrecision] => 0 ) [46] => Array ( [entSensorType] => rpm [entSensorScale] => units [entSensorValue] => 4319 [entSensorMeasuredEntity] => 43 [entSensorPrecision] => 0 ) [47] => Array ( [entSensorType] => rpm [entSensorScale] => units [entSensorValue] => 4384 [entSensorMeasuredEntity] => 43 [entSensorPrecision] => 0 ) [48] => Array ( [entSensorType] => watts [entSensorScale] => units [entSensorValue] => 5 [entSensorMeasuredEntity] => 43 [entSensorPrecision] => 0 ) [7001] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 19 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7002] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 18 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7003] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 25 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7004] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 28 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7005] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 39 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7006] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 33 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7007] => Array ( [entSensorType] => celsius [entSensorScale] => units [entSensorValue] => 36 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7008] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 12450 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7009] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 5104 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7010] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 3331 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7011] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 3006 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7012] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 2436 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7013] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1044 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7014] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1808 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7015] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1228 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7016] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1155 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7017] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1112 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7018] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1023 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7019] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1787 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7020] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1513 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7021] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1526 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7022] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1513 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7023] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1002 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7024] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 1511 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7025] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 915 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7026] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 909 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7027] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 759 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7028] => Array ( [entSensorType] => voltsDC [entSensorScale] => milli [entSensorValue] => 770 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7029] => Array ( [entSensorType] => amperes [entSensorScale] => units [entSensorValue] => 5 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) [7030] => Array ( [entSensorType] => watts [entSensorScale] => units [entSensorValue] => 56 [entSensorMeasuredEntity] => 7000 [entSensorPrecision] => 0 ) ) Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.4, 4, cisco-entity-sensor, Power Supply Module 0 - Temp 1 P0/0, snmp, 1, 1, 4, 35 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","4"][0m 0.33ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","4"][0m 0.21ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.5, 5, cisco-entity-sensor, Power Supply Module 0 - Temp 2 P0/1, snmp, 1, 1, 5, 29 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","5"][0m 0.15ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","5"][0m 0.18ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.6, 6, cisco-entity-sensor, Power Supply Module 0 - Temp 3 P0/2, snmp, 1, 1, 6, 38 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","6"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","6"][0m 0.18ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7, 7, cisco-entity-sensor, Power Supply Module 0 - V: PEM Out P0/3, snmp, 1000, 1, 7, 12.447 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7"][0m 0.15ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.8, 8, cisco-entity-sensor, Power Supply Module 0 - I: PEM In P0/4, snmp, 1, 1, 8, 1 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",7,"cisco-entity-sensor","8"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",7,"cisco-entity-sensor","8"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.9, 9, cisco-entity-sensor, Power Supply Module 0 - I: PEM Out P0/5, snmp, 1, 1, 9, 5 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",7,"cisco-entity-sensor","9"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",7,"cisco-entity-sensor","9"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.10, 10, cisco-entity-sensor, Power Supply Module 0 - P: In Pwr P0/6, snmp, 1, 1, 10, 72 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","power",7,"cisco-entity-sensor","10"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["power",7,"cisco-entity-sensor","10"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.11, 11, cisco-entity-sensor, Power Supply Module 0 - P: Out Pwr P0/7, snmp, 1, 1, 11, 61 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","power",7,"cisco-entity-sensor","11"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["power",7,"cisco-entity-sensor","11"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.12, 12, cisco-entity-sensor, Power Supply Module 0 - RPM: Fan0 P0/8, snmp, 1, 1, 12, 2924 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","fanspeed",7,"cisco-entity-sensor","12"][0m 0.13ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["fanspeed",7,"cisco-entity-sensor","12"][0m 0.27ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.44, 44, cisco-entity-sensor, Fan Tray - RPM: Fan0 P2/0, snmp, 1, 1, 44, 4236 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","fanspeed",7,"cisco-entity-sensor","44"][0m 0.17ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["fanspeed",7,"cisco-entity-sensor","44"][0m 0.2ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.45, 45, cisco-entity-sensor, Fan Tray - RPM: Fan1 P2/1, snmp, 1, 1, 45, 4458 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","fanspeed",7,"cisco-entity-sensor","45"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["fanspeed",7,"cisco-entity-sensor","45"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.46, 46, cisco-entity-sensor, Fan Tray - RPM: Fan2 P2/2, snmp, 1, 1, 46, 4319 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","fanspeed",7,"cisco-entity-sensor","46"][0m 0.12ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["fanspeed",7,"cisco-entity-sensor","46"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.47, 47, cisco-entity-sensor, Fan Tray - RPM: Fan3 P2/3, snmp, 1, 1, 47, 4384 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","fanspeed",7,"cisco-entity-sensor","47"][0m 0.11ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["fanspeed",7,"cisco-entity-sensor","47"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.48, 48, cisco-entity-sensor, Fan Tray - P: Pwr P2/4, snmp, 1, 1, 48, 5 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","power",7,"cisco-entity-sensor","48"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["power",7,"cisco-entity-sensor","48"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7001, 7001, cisco-entity-sensor, Module R0 - Inlet 1 R0/0, snmp, 1, 1, 7001, 19 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7001"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7001"][0m 0.17ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7002, 7002, cisco-entity-sensor, Module R0 - Inlet 2 R0/1, snmp, 1, 1, 7002, 18 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7002"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7002"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7003, 7003, cisco-entity-sensor, Module R0 - Outlet 1 R0/2, snmp, 1, 1, 7003, 25 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7003"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7003"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7004, 7004, cisco-entity-sensor, Module R0 - Outlet 2 R0/3, snmp, 1, 1, 7004, 28 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7004"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7004"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7005, 7005, cisco-entity-sensor, Module R0 - Core-A R0/4, snmp, 1, 1, 7005, 39 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7005"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7005"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7006, 7006, cisco-entity-sensor, Module R0 - Core-B R0/5, snmp, 1, 1, 7006, 33 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7006"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7006"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7007, 7007, cisco-entity-sensor, Module R0 - Core-C R0/6, snmp, 1, 1, 7007, 36 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","temperature",7,"cisco-entity-sensor","7007"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["temperature",7,"cisco-entity-sensor","7007"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7008, 7008, cisco-entity-sensor, Module R0 - V: 12v R0/7, snmp, 1000, 1, 7008, 12.45 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7008"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7008"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7009, 7009, cisco-entity-sensor, Module R0 - V: 5v R0/8, snmp, 1000, 1, 7009, 5.104 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7009"][0m 0.11ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7009"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7010, 7010, cisco-entity-sensor, Module R0 - V: 3.3v R0/9, snmp, 1000, 1, 7010, 3.331 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7010"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7010"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7011, 7011, cisco-entity-sensor, Module R0 - V: 3.0v R0/10, snmp, 1000, 1, 7011, 3.006 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7011"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7011"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7012, 7012, cisco-entity-sensor, Module R0 - V: 2.5v R0/11, snmp, 1000, 1, 7012, 2.436 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7012"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7012"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7013, 7013, cisco-entity-sensor, Module R0 - V: 1.05v R0/12, snmp, 1000, 1, 7013, 1.044 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7013"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7013"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7014, 7014, cisco-entity-sensor, Module R0 - V: 1.8v R0/13, snmp, 1000, 1, 7014, 1.808 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7014"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7014"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7015, 7015, cisco-entity-sensor, Module R0 - V: 1.2v R0/14, snmp, 1000, 1, 7015, 1.228 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7015"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7015"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7016, 7016, cisco-entity-sensor, Module R0 - V: Vcore-C R0/15, snmp, 1000, 1, 7016, 1.155 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7016"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7016"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7017, 7017, cisco-entity-sensor, Module R0 - V: 1.1v R0/16, snmp, 1000, 1, 7017, 1.112 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7017"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7017"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7018, 7018, cisco-entity-sensor, Module R0 - V: 1.0v R0/17, snmp, 1000, 1, 7018, 1.023 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7018"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7018"][0m 0.13ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7019, 7019, cisco-entity-sensor, Module R0 - V: 1.8v-A R0/18, snmp, 1000, 1, 7019, 1.787 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7019"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7019"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7020, 7020, cisco-entity-sensor, Module R0 - V: 1.5v-A R0/19, snmp, 1000, 1, 7020, 1.513 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7020"][0m 0.09ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7020"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7021, 7021, cisco-entity-sensor, Module R0 - V: 1.5v-C1 R0/20, snmp, 1000, 1, 7021, 1.526 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7021"][0m 0.11ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7021"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7022, 7022, cisco-entity-sensor, Module R0 - V: 1.5v-B R0/21, snmp, 1000, 1, 7022, 1.513 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7022"][0m 0.17ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7022"][0m 0.13ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7023, 7023, cisco-entity-sensor, Module R0 - V: Vcore-A R0/22, snmp, 1000, 1, 7023, 1.002 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7023"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7023"][0m 0.11ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7024, 7024, cisco-entity-sensor, Module R0 - V: 1.5v-C2 R0/23, snmp, 1000, 1, 7024, 1.511 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7024"][0m 0.14ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7024"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7025, 7025, cisco-entity-sensor, Module R0 - V: Vcore-B1 R0/24, snmp, 1000, 1, 7025, 0.915 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7025"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7025"][0m 0.16ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7026, 7026, cisco-entity-sensor, Module R0 - V: Vcore-B2 R0/25, snmp, 1000, 1, 7026, 0.909 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7026"][0m 0.13ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7026"][0m 0.13ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7027, 7027, cisco-entity-sensor, Module R0 - V: 0.75v-B R0/26, snmp, 1000, 1, 7027, 0.759 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7027"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7027"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7028, 7028, cisco-entity-sensor, Module R0 - V: 0.75v-C R0/27, snmp, 1000, 1, 7028, 0.77 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",7,"cisco-entity-sensor","7028"][0m 0.1ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",7,"cisco-entity-sensor","7028"][0m 0.12ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7029, 7029, cisco-entity-sensor, Module R0 - I: 12v R0/28, snmp, 1, 1, 7029, 5 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",7,"cisco-entity-sensor","7029"][0m 6.44ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",7,"cisco-entity-sensor","7029"][0m 0.14ms] .Discover sensor: .1.3.6.1.4.1.9.9.91.1.1.1.1.4.7030, 7030, cisco-entity-sensor, Module R0 - P: Pwr R0/29, snmp, 1, 1, 7030, 56 SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","power",7,"cisco-entity-sensor","7030"][0m 0.11ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["power",7,"cisco-entity-sensor","7030"][0m 0.13ms] . ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID entPhySensorOperStatusSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhySensorOperStatus[0m] entPhySensorOperStatus = No Such Object available on this agent at this OID SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[7,"ipmi_hostname"][0m 0.31ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",7,"ipmi"][0m 1.03ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",7,"ipmi"][0m 0.58ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",7,"ipmi"][0m 0.52ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",7,"ipmi"][0m 0.53ms] Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",7,"snmp"][0m 0.47ms] Current: Array ( [cisco-entity-sensor] => Array ( [8] => 1 [9] => 1 [7029] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",7,"snmp"][0m 0.63ms] 8 -> cisco-entity-sensor 9 -> cisco-entity-sensor 7029 -> cisco-entity-sensor Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",7,"snmp"][0m 0.5ms] Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",7,"snmp"][0m 0.46ms] Fanspeed: Array ( [cisco-entity-sensor] => Array ( [12] => 1 [44] => 1 [45] => 1 [46] => 1 [47] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",7,"snmp"][0m 0.63ms] 12 -> cisco-entity-sensor 44 -> cisco-entity-sensor 45 -> cisco-entity-sensor 46 -> cisco-entity-sensor 47 -> cisco-entity-sensor Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",7,"snmp"][0m 0.5ms] Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",7,"snmp"][0m 0.47ms] Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",7,"snmp"][0m 0.48ms] Power: Array ( [cisco-entity-sensor] => Array ( [10] => 1 [11] => 1 [48] => 1 [7030] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",7,"snmp"][0m 0.59ms] 10 -> cisco-entity-sensor 11 -> cisco-entity-sensor 48 -> cisco-entity-sensor 7030 -> cisco-entity-sensor Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",7,"snmp"][0m 0.55ms] Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",7,"snmp"][0m 0.86ms] State: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswSwitchRole[0m] cswSwitchRole = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQv -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswRingRedundant.0[0m] No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonVoltageStatusTable[0m] ciscoEnvMonVoltageStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonTemperatureStatusTable[0m] ciscoEnvMonTemperatureStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonFanStatusTable[0m] ciscoEnvMonFanStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENVMON-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ciscoEnvMonSupplyStatusTable[0m] ciscoEnvMonSupplyStatusTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-FRU-CONTROL-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cefcFRUPowerStatusTable[0m] cefcFRUPowerAdminStatus.3 = on cefcFRUPowerOperStatus.3 = on cefcFRUCurrent.3 = 5 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 entPhysicalName.3[0m] Power Supply Module 0 Discover sensor: .1.3.6.1.4.1.9.9.117.1.1.2.1.2.3, 3, cefcFRUPowerOperStatus, Power Supply Module 0, snmp, 1, 1, 3, on SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","state",7,"cefcFRUPowerOperStatus","3"][0m 0.29ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",7,"cefcFRUPowerOperStatus","3"][0m 0.15ms] .SQL[[1;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["state",7,"cefcFRUPowerOperStatus",3][0m 0.09ms] SQL[[1;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = ? [0;33m["cefcFRUPowerOperStatus"][0m 0.09ms] SQL[[1;33mINSERT IGNORE INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES (:sensor_id,:state_index_id) [0;33m{"sensor_id":95,"state_index_id":5}[0m 0.55ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswGlobals[0m] cswGlobals = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswSwitchRole[0m] cswSwitchRole = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswSwitchState[0m] cswSwitchState = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-STACKWISE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cswStackPortOperStatus[0m] cswStackPortOperStatus = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-RF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cRFCfgRedundancyOperMode[0m] cRFCfgRedundancyOperMode.0 = nonRedundant Array ( [cefcFRUPowerOperStatus] => Array ( [3] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",7,"snmp"][0m 0.81ms] 3 -> cefcFRUPowerOperStatus Temperature: Array ( [cisco-entity-sensor] => Array ( [4] => 1 [5] => 1 [6] => 1 [7001] => 1 [7002] => 1 [7003] => 1 [7004] => 1 [7005] => 1 [7006] => 1 [7007] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",7,"snmp"][0m 0.81ms] 4 -> cisco-entity-sensor 5 -> cisco-entity-sensor 6 -> cisco-entity-sensor 7001 -> cisco-entity-sensor 7002 -> cisco-entity-sensor 7003 -> cisco-entity-sensor 7004 -> cisco-entity-sensor 7005 -> cisco-entity-sensor 7006 -> cisco-entity-sensor 7007 -> cisco-entity-sensor Voltage: Array ( [cisco-entity-sensor] => Array ( [7] => 1 [7008] => 1 [7009] => 1 [7010] => 1 [7011] => 1 [7012] => 1 [7013] => 1 [7014] => 1 [7015] => 1 [7016] => 1 [7017] => 1 [7018] => 1 [7019] => 1 [7020] => 1 [7021] => 1 [7022] => 1 [7023] => 1 [7024] => 1 [7025] => 1 [7026] => 1 [7027] => 1 [7028] => 1 ) ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",7,"snmp"][0m 0.97ms] 7 -> cisco-entity-sensor 7008 -> cisco-entity-sensor 7009 -> cisco-entity-sensor 7010 -> cisco-entity-sensor 7011 -> cisco-entity-sensor 7012 -> cisco-entity-sensor 7013 -> cisco-entity-sensor 7014 -> cisco-entity-sensor 7015 -> cisco-entity-sensor 7016 -> cisco-entity-sensor 7017 -> cisco-entity-sensor 7018 -> cisco-entity-sensor 7019 -> cisco-entity-sensor 7020 -> cisco-entity-sensor 7021 -> cisco-entity-sensor 7022 -> cisco-entity-sensor 7023 -> cisco-entity-sensor 7024 -> cisco-entity-sensor 7025 -> cisco-entity-sensor 7026 -> cisco-entity-sensor 7027 -> cisco-entity-sensor 7028 -> cisco-entity-sensor Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",7,"snmp"][0m 1ms] Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",7,"snmp"][0m 0.48ms] Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",7,"snmp"][0m 0.75ms] Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",7,"snmp"][0m 0.79ms] Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",7,"snmp"][0m 0.43ms] Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",7,"snmp"][0m 0.48ms] Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",7,"snmp"][0m 1.11ms] Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",7,"snmp"][0m 0.49ms] Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",7,"snmp"][0m 0.46ms] >> Runtime for discovery module 'sensors': 0.5980 seconds with 353160 bytes >> SNMP: [26/0.48s] MySQL: [76/0.03s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco:/opt/librenms/mibs/datadomain udp:HOSTNAME:161 fileSystemSpaceTable[0m] fileSystemSpaceTable = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '7' AND `storage_type` != 'dsk' [0;33m[][0m 0.31ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '7' [0;33m[][0m 0.18ms] >> Runtime for discovery module 'storage': 0.0430 seconds with 9120 bytes >> SNMP: [3/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '7' [0;33m[][0m 0.27ms] >> Runtime for discovery module 'hr-device': 0.0250 seconds with 3680 bytes >> SNMP: [2/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cdpCache[0m] cdpCacheAddressType[1][1] = 1 cdpCacheAddressType[2][3] = 1 cdpCacheAddressType[4][2] = 1 cdpCacheAddress[1][1] = "3F C0 9E 41 " cdpCacheAddress[2][3] = "0A 0A 58 01 " cdpCacheAddress[4][2] = "0A 0A 58 01 " cdpCacheVersion[1][1] = 6.38.5 (stable) cdpCacheVersion[2][3] = Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team cdpCacheVersion[4][2] = Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2) Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team cdpCacheDeviceId[1][1] = SonomaRaceway cdpCacheDeviceId[2][3] = S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL cdpCacheDeviceId[4][2] = S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL cdpCacheDevicePort[1][1] = Lan Bridge cdpCacheDevicePort[2][3] = GigabitEthernet1/0/24 cdpCacheDevicePort[4][2] = GigabitEthernet1/0/22 cdpCachePlatform[1][1] = MikroTik cdpCachePlatform[2][3] = cisco WS-C2960XR-24PS-I cdpCachePlatform[4][2] = cisco WS-C2960XR-24PS-I cdpCacheCapabilities[1][1] = "00 00 00 01 " cdpCacheCapabilities[2][3] = "00 00 00 29 " cdpCacheCapabilities[4][2] = "00 00 00 29 " cdpCacheVTPMgmtDomain[2][3] = Infineon cdpCacheVTPMgmtDomain[4][2] = Infineon cdpCacheNativeVLAN[1][1] = 0 cdpCacheNativeVLAN[2][3] = 40 cdpCacheNativeVLAN[4][2] = 41 cdpCacheDuplex[1][1] = 1 cdpCacheDuplex[2][3] = 3 cdpCacheDuplex[4][2] = 3 cdpCacheLastChange[1][1] = 3611732556 cdpCacheLastChange[2][3] = 3611695505 cdpCacheLastChange[4][2] = 3611714703 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,1][0m 0.48ms] Array ( [cdpCacheAddressType] => 1 [cdpCacheAddress] => 3F C0 9E 41 [cdpCacheVersion] => 6.38.5 (stable) [cdpCacheDeviceId] => SonomaRaceway [cdpCacheDevicePort] => Lan Bridge [cdpCachePlatform] => MikroTik [cdpCacheCapabilities] => 00 00 00 01 [cdpCacheNativeVLAN] => 0 [cdpCacheDuplex] => 1 [cdpCacheLastChange] => 3611732556 ) SQL[[1;33mSELECT `device_id` FROM `devices` WHERE `sysName`=? OR `hostname`=? OR `hostname`=? OR `ip`=? [0;33m[0m 0.66ms] discovering SonomaRaceway name lookup of SonomaRaceway failed SQL[[1;33mSELECT `devices`.*, `location`, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.location_id=`locations`.`id` WHERE `device_id` = ? [0;33m[7][0m 0.75ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[7][0m 0.19ms] SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[7][0m 0.17ms] SQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":7,"device_id":7,"reference":"NULL","type":"discovery","severity":5,"message":"CDP discovery of SonomaRaceway failed - Check name lookup","username":""}[0m 0.52ms] Discover link: 233, cdp, 0, SonomaRaceway, Lan Bridge, MikroTik, 6.38.5 (stable), SQL[[1;33mSELECT COUNT(*) FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["SonomaRaceway",233,"cdp","Lan Bridge"][0m 0.13ms] SQL[[1;33mSELECT `id`,`local_device_id`,`remote_platform`,`remote_version`,`remote_device_id`,`remote_port_id` FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["SonomaRaceway",233,"cdp","Lan Bridge"][0m 0.11ms] .SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,2][0m 0.19ms] Array ( [cdpCacheAddressType] => 1 [cdpCacheAddress] => 0A 0A 58 01 [cdpCacheVersion] => Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team [cdpCacheDeviceId] => S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL [cdpCacheDevicePort] => GigabitEthernet1/0/24 [cdpCachePlatform] => cisco WS-C2960XR-24PS-I [cdpCacheCapabilities] => 00 00 00 29 [cdpCacheVTPMgmtDomain] => Infineon [cdpCacheNativeVLAN] => 40 [cdpCacheDuplex] => 3 [cdpCacheLastChange] => 3611695505 ) SQL[[1;33mSELECT `device_id` FROM `devices` WHERE `sysName`=? OR `hostname`=? OR `hostname`=? OR `ip`=? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL","S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",{"ip":"10.10.88.1","cidr":32,"host_bits":32},"\n\nX\u0001"][0m 0.28ms] SQL[[1;33mSELECT * FROM (SELECT `port_id` FROM `ports` WHERE `device_id`=? AND (`ifDescr`=? OR `ifName`=?) UNION SELECT `port_id` FROM `ports` WHERE `device_id`=? AND `ifAlias`=? LIMIT 1) p [0;33m[89,"GigabitEthernet1\/0\/24","GigabitEthernet1\/0\/24",89,"GigabitEthernet1\/0\/24"][0m 0.18ms] Discover link: 234, cdp, 2585, S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL, GigabitEthernet1/0/24, cisco WS-C2960XR-24PS-I, Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team, 89 SQL[[1;33mSELECT COUNT(*) FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",234,"cdp","GigabitEthernet1\/0\/24"][0m 0.11ms] SQL[[1;33mSELECT `id`,`local_device_id`,`remote_platform`,`remote_version`,`remote_device_id`,`remote_port_id` FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",234,"cdp","GigabitEthernet1\/0\/24"][0m 0.11ms] .SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,4][0m 0.18ms] Array ( [cdpCacheAddressType] => 1 [cdpCacheAddress] => 0A 0A 58 01 [cdpCacheVersion] => Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team [cdpCacheDeviceId] => S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL [cdpCacheDevicePort] => GigabitEthernet1/0/22 [cdpCachePlatform] => cisco WS-C2960XR-24PS-I [cdpCacheCapabilities] => 00 00 00 29 [cdpCacheVTPMgmtDomain] => Infineon [cdpCacheNativeVLAN] => 41 [cdpCacheDuplex] => 3 [cdpCacheLastChange] => 3611714703 ) SQL[[1;33mSELECT `device_id` FROM `devices` WHERE `sysName`=? OR `hostname`=? OR `hostname`=? OR `ip`=? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL","S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",{"ip":"10.10.88.1","cidr":32,"host_bits":32},"\n\nX\u0001"][0m 0.11ms] SQL[[1;33mSELECT * FROM (SELECT `port_id` FROM `ports` WHERE `device_id`=? AND (`ifDescr`=? OR `ifName`=?) UNION SELECT `port_id` FROM `ports` WHERE `device_id`=? AND `ifAlias`=? LIMIT 1) p [0;33m[89,"GigabitEthernet1\/0\/22","GigabitEthernet1\/0\/22",89,"GigabitEthernet1\/0\/22"][0m 0.13ms] Discover link: 236, cdp, 2583, S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL, GigabitEthernet1/0/22, cisco WS-C2960XR-24PS-I, Cisco IOS Software, C2960X Software (C2960X-UNIVERSALK9-M), Version 15.2(2)E5, RELEASE SOFTWARE (fc2)Technical Support: http://www.cisco.com/techsupport Copyright (c) 1986-2016 by Cisco Systems, Inc. Compiled Thu 02-Jun-16 01:31 by prod_rel_team, 89 SQL[[1;33mSELECT COUNT(*) FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",236,"cdp","GigabitEthernet1\/0\/22"][0m 0.1ms] SQL[[1;33mSELECT `id`,`local_device_id`,`remote_platform`,`remote_version`,`remote_device_id`,`remote_port_id` FROM `links` WHERE `remote_hostname` = ? AND `local_port_id` = ? AND `protocol` = ? AND `remote_port` = ? [0;33m["S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL",236,"cdp","GigabitEthernet1\/0\/22"][0m 0.11ms] . LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 lldpRemTable[0m] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[7][0m 0.36ms] Array ( [233] => Array ( [SonomaRaceway] => Array ( [Lan Bridge] => 1 ) ) [234] => Array ( [S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL] => Array ( [GigabitEthernet1/0/24] => 1 ) ) [236] => Array ( [S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL] => Array ( [GigabitEthernet1/0/22] => 1 ) ) ) SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[7][0m 3.83ms] 233 -> SonomaRaceway -> Lan Bridge 234 -> S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL -> GigabitEthernet1/0/24 236 -> S-ADMIN-SERVERROOM-XR.SONOMA.INTERNAL -> GigabitEthernet1/0/22 SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.82ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.0550 seconds with 50688 bytes >> SNMP: [0/0.00s] MySQL: [13/0.01s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress[1][ipv4]["*"] = 64:d1:54:db:44:fd ipNetToPhysicalPhysAddress[1][ipv4]["*"] = 0:35:1a:84:26:0 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 0:35:1a:84:26:1 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 0:2c:c8:5:15:f9 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = c2:ea:e4:f6:67:c1 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = c0:67:af:a2:90:0 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = a0:40:a0:a2:e4:69 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = 2c:33:11:ee:6a:72 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = c0:ea:e4:f6:67:c1 ipNetToPhysicalPhysAddress[2][ipv4]["*"] = c0:ea:e4:f7:fb:d5 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:35:1a:84:26:3 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:9:5b:d3:b5:94 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:f:b5:5f:17:7d ipNetToPhysicalPhysAddress[4][ipv4]["*"] = c0:56:27:25:86:39 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = b0:7f:b9:9c:d:61 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 18:b1:69:86:2a:ad ipNetToPhysicalPhysAddress[4][ipv4]["*"] = c4:3d:c7:4c:d6:58 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:16:b6:1b:51:98 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:1d:9:82:e6:d8 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = a0:40:a0:a8:64:df ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:1b:2f:31:36:cd ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 90:e6:ba:bc:7a:1b ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 58:20:b1:dd:dc:15 ipNetToPhysicalPhysAddress[4][ipv4]["*"] = 0:d:b9:47:25:c1 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress[1][*] = 64:d1:54:db:44:fd ipNetToMediaPhysAddress[1][*] = 0:35:1a:84:26:0 ipNetToMediaPhysAddress[2][*] = 0:35:1a:84:26:1 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = 0:2c:c8:5:15:f9 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = c2:ea:e4:f6:67:c1 ipNetToMediaPhysAddress[2][*] = c0:67:af:a2:90:0 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = a0:40:a0:a2:e4:69 ipNetToMediaPhysAddress[2][*] = 2c:33:11:ee:6a:72 ipNetToMediaPhysAddress[2][*] = c0:ea:e4:f6:67:c1 ipNetToMediaPhysAddress[2][*] = c0:ea:e4:f7:fb:d5 ipNetToMediaPhysAddress[4][*] = 0:35:1a:84:26:3 ipNetToMediaPhysAddress[4][*] = 0:9:5b:d3:b5:94 ipNetToMediaPhysAddress[4][*] = 0:f:b5:5f:17:7d ipNetToMediaPhysAddress[4][*] = c0:56:27:25:86:39 ipNetToMediaPhysAddress[4][*] = b0:7f:b9:9c:d:61 ipNetToMediaPhysAddress[4][*] = 18:b1:69:86:2a:ad ipNetToMediaPhysAddress[4][*] = c4:3d:c7:4c:d6:58 ipNetToMediaPhysAddress[4][*] = 0:16:b6:1b:51:98 ipNetToMediaPhysAddress[4][*] = 0:1d:9:82:e6:d8 ipNetToMediaPhysAddress[4][*] = a0:40:a0:a8:64:df ipNetToMediaPhysAddress[4][*] = 0:1b:2f:31:36:cd ipNetToMediaPhysAddress[4][*] = 90:e6:ba:bc:7a:1b ipNetToMediaPhysAddress[4][*] = 58:20:b1:dd:dc:15 ipNetToMediaPhysAddress[4][*] = 0:d:b9:47:25:c1 SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[7,""][0m 0.24ms] SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,1][0m 0.23ms] Gi0/0/0: 64:d1:54:db:44:fd => 63.192.158.65 0:35:1a:84:26:0 => 63.192.158.66 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,2][0m 0.18ms] Gi0/0/1: 0:35:1a:84:26:1 => 63.192.158.1 2c:33:11:ee:6a:72 => 63.192.158.2 2c:33:11:ee:6a:72 => 63.192.158.3 0:2c:c8:5:15:f9 => 63.192.158.4 2c:33:11:ee:6a:72 => 63.192.158.5 2c:33:11:ee:6a:72 => 63.192.158.6 2c:33:11:ee:6a:72 => 63.192.158.8 c2:ea:e4:f6:67:c1 => 63.192.158.9 c0:67:af:a2:90:0 => 63.192.158.10 2c:33:11:ee:6a:72 => 63.192.158.12 a0:40:a0:a2:e4:69 => 63.192.158.27 2c:33:11:ee:6a:72 => 63.192.158.28 c0:ea:e4:f6:67:c1 => 63.192.158.29 c0:ea:e4:f7:fb:d5 => 63.192.158.30 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[7,4][0m 0.17ms] Gi0/0/3: 0:35:1a:84:26:3 => 63.192.158.33 0:9:5b:d3:b5:94 => 63.192.158.34 0:f:b5:5f:17:7d => 63.192.158.36 c0:56:27:25:86:39 => 63.192.158.37 b0:7f:b9:9c:d:61 => 63.192.158.38 18:b1:69:86:2a:ad => 63.192.158.42 c4:3d:c7:4c:d6:58 => 63.192.158.43 0:16:b6:1b:51:98 => 63.192.158.44 0:1d:9:82:e6:d8 => 63.192.158.46 a0:40:a0:a8:64:df => 63.192.158.47 0:1b:2f:31:36:cd => 63.192.158.48 90:e6:ba:bc:7a:1b => 63.192.158.49 58:20:b1:dd:dc:15 => 63.192.158.50 0:d:b9:47:25:c1 => 63.192.158.52 SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 3.64ms] >> Runtime for discovery module 'arp-table': 0.0290 seconds with 30472 bytes >> SNMP: [0/0.00s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 bgpLocalAs[0m] 0 AS0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oq -m CISCO-BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 cbgpPeer2RemoteAs[0m] CISCO-BGP4-MIB::cbgpPeer2RemoteAs No Such Instance currently exists at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oq -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 bgpPeerRemoteAs[0m] BGP4-MIB::bgpPeerRemoteAs No Such Instance currently exists at this OID Peers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[7,""][0m 0.3ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[7,""][0m 0.27ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[7][0m 0.1ms] >> Runtime for discovery module 'bgp-peers': 0.0290 seconds with 5584 bytes >> SNMP: [3/0.03s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[7][0m 0.12ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Instance currently exists at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID Cisco VLANs: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vlanTrunkPortNativeVlan[0m] vlanTrunkPortNativeVlan = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-VLAN-MEMBERSHIP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vmVlan[0m] vmVlan = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OnvQ -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vtpVersion.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0540 seconds with 9360 bytes >> SNMP: [5/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '7' [0;33m[][0m 0.32ms] >> Runtime for discovery module 'ucd-diskio': 0.0080 seconds with 3160 bytes >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[7][0m 0.27ms] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Instance currently exists at this OID >> Runtime for discovery module 'stp': 0.0120 seconds with 5792 bytes >> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### SQL[[1;33mSELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = ? AND `type` = ? ) [0;33m[7,"ntp"][0m 0.32ms] Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 .1.3.6.1.4.1.9.9.168.1.2.1.1[0m] .*.*.*.1.2.5220 1 .*.*.*.1.3.5220 * .*.*.*.1.4.5220 123 .*.*.*.1.5.5220 * .*.*.*.1.6.5220 123 .*.*.*.1.7.5220 0 .*.*.*.1.8.5220 4 .*.*.*.1.9.5220 2 .*.*.*.1.10.5220 10 .*.*.*.1.11.5220 10 .*.*.*.1.12.5220 -20 .*.*.*.1.13.5220 "00 00 00 14 " .*.*.*.1.14.5220 "00 00 01 22 " .*.*.*.1.15.5220 "D8 E4 C0 35 " .*.*.*.1.16.5220 "DF B3 4B 67 98 78 9C 44 " .*.*.*.1.17.5220 "00 00 00 00 00 00 00 00 " .*.*.*.1.18.5220 "DF B3 4B 6E 8C 5C 8E FB " .*.*.*.1.19.5220 "DF B3 4B 6E 8C 5C 8E FB " .*.*.*.1.20.5220 1265080440 .*.*.*.1.21.5220 255 .*.*.*.1.22.5220 0 .*.*.*.1.23.5220 "00 00 00 00 " .*.*.*.1.24.5220 "00 26 86 AC " .*.*.*.1.25.5220 "00 01 22 27 " .*.*.*.1.26.5220 8 .*.*.*.1.27.5220 1 .*.*.*.1.28.5220 1265080440 .*.*.*.1.29.5220 2 Objects Found: NTP Peer found: Array ( [UID] => 5220 [peer] => 216.228.192.51 [port] => 123 [stratum] => 2 [peerref] => LibreNMS\Util\IPv4 Object ( [ip] => 216.228.192.53 [cidr] => 32 [host_bits] => 32 ) [label] => 216.228.192.51:123 [status] => 0 [error] => ) .SQL[[1;33mSELECT `C`.`id`,`C`.`device_id`,`C`.`type`,`C`.`label`,`C`.`status`,`C`.`disabled`,`C`.`ignore`,`C`.`error`,`CP`.`attribute`,`CP`.`value` FROM `component` as `C` LEFT JOIN `component_prefs` as `CP` on `C`.`id`=`CP`.`component` WHERE ( `device_id` = ? ) [0;33m[7][0m 0.31ms] Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 162 Warning: Illegal offset type in /opt/librenms/LibreNMS/Component.php on line 165 SQL[[1;33mSELECT COUNT(*) FROM `applications` WHERE `device_id` = ? AND `app_type` = ? [0;33m[7,"ntp"][0m 0.17ms] >> Runtime for discovery module 'ntp': 0.0120 seconds with 17016 bytes >> SNMP: [1/0.01s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### ap-count: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 CISCO-LWAPP-SYS-MIB::clsSysApConnectCount.0 AIRESPACE-SWITCHING-MIB::agentInventoryMaxNumberOfAPsSupported.0[0m] clsSysApConnectCount.0 = No Such Object available on this agent at this OID agentInventoryMaxNumberOfAPsSupported.0 = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"ap-count"][0m 0.33ms] clients: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m AIRESPACE-WIRELESS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 bsnDot11EssSsid[0m] bsnDot11EssSsid = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m AIRESPACE-WIRELESS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 bsnDot11EssNumberOfMobileStations[0m] bsnDot11EssNumberOfMobileStations = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"clients"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"quality"][0m 0.23ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"capacity"][0m 0.22ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"utilization"][0m 0.23ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"rate"][0m 0.21ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"ccq"][0m 0.21ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"snr"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"ssr"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"mse"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"rssi"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"power"][0m 0.21ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"noise-floor"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"errors"][0m 0.24ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"error-ratio"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"error-rate"][0m 0.21ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"frequency"][0m 0.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[7,"distance"][0m 0.25ms] >> Runtime for discovery module 'wireless': 0.0710 seconds with 204736 bytes >> SNMP: [3/0.06s] MySQL: [18/0.01s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[7][0m 0.18ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[7][0m 0.15ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 managementDomainName[0m] managementDomainName = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-VTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 vtpVlanEntry[0m] vtpVlanEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/cisco udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Instance currently exists at this OID >> Runtime for discovery module 'fdb-table': 0.0610 seconds with 1480 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[7,"poll_mib"][0m 0.35ms] SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[2.769,7][0m 0.87ms] Discovered in 2.769 seconds SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"sonoma-edge","start":1544080633.3347,"duration":"2.972","devices":1,"poller":"ssw-netmon"}[0m 1ms] ./discovery.php sonoma-edge 2018-12-05 23:17:16 - 1 devices discovered in 2.972 secs SNMP [84/1.32s]: Get[16/0.19s] Getnext[1/0.01s] Walk[67/1.12s] MySQL [241/0.13s]: Cell[161/0.04s] Row[-96/-0.02s] Rows[71/0.04s] Column[2/0.00s] Update[94/0.05s] Insert[4/0.01s] Delete[5/0.01s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]