LibreNMS Discovery Version info: Commit SHA: 75d62aa068944e17948253781b3805140a98f813 DB Schema: 186 PHP: 7.0.15-0ubuntu0.16.04.4 MySQL: 10.0.29-MariaDB-0ubuntu0.16.04.1 RRDTool: 1.5.5 SNMP: NET-SNMP 5.7.3 DEBUG! SQL[[0;33mSELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1[0m] DB Schema already up to date. SQL[[0;33mSELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'lg-testucp' ORDER BY device_id DESC[0m] SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '49'[0m] lg-testucp 49 ELG-UCP100 SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.59','0.96','0.76','49',NOW())[0m] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Ericsson-LG,UCP100,UCP-R2.0.16&Boot Version-1.0Da JAN/16 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.572.16838 | Ericsson-LG,UCP100,UCP-R2.0.16&Boot Version-1.0Da JAN/16 | .1.3.6.1.4.1.572.16838 | SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs udp:HOSTNAME:161 ENTITY-MIB::entPhysicalDescr.1[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'os': 0.1550 seconds with 89696 bytes #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = lo ifDescr.2 = eth1 ifDescr.3 = eth0 ifDescr.4 = eth2 ifDescr.5 = gre0 ifDescr.6 = sit0 ifDescr.7 = ip6tnl0 ifDescr.8 = ethipip6tnl0 ifDescr.9 = ippp0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName[0m] ifName.1 = lo ifName.2 = eth1 ifName.3 = eth0 ifName.4 = eth2 ifName.5 = gre0 ifName.6 = sit0 ifName.7 = ip6tnl0 ifName.8 = ethipip6tnl0 ifName.9 = ippp0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias[0m] ifAlias.1 = ifAlias.2 = ifAlias.3 = ifAlias.4 = ifAlias.5 = ifAlias.6 = ifAlias.7 = ifAlias.8 = ifAlias.9 = SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = tunnel ifType.6 = tunnel ifType.7 = tunnel ifType.8 = ethernetCsmacd ifType.9 = ppp Array ( [1] => Array ( [ifDescr] => lo [ifName] => lo [ifAlias] => [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => eth1 [ifName] => eth1 [ifAlias] => [ifType] => ethernetCsmacd ) [3] => Array ( [ifDescr] => eth0 [ifName] => eth0 [ifAlias] => [ifType] => ethernetCsmacd ) [4] => Array ( [ifDescr] => eth2 [ifName] => eth2 [ifAlias] => [ifType] => ethernetCsmacd ) [5] => Array ( [ifDescr] => gre0 [ifName] => gre0 [ifAlias] => [ifType] => tunnel ) [6] => Array ( [ifDescr] => sit0 [ifName] => sit0 [ifAlias] => [ifType] => tunnel ) [7] => Array ( [ifDescr] => ip6tnl0 [ifName] => ip6tnl0 [ifAlias] => [ifType] => tunnel ) [8] => Array ( [ifDescr] => ethipip6tnl0 [ifName] => ethipip6tnl0 [ifAlias] => [ifType] => ethernetCsmacd ) [9] => Array ( [ifDescr] => ippp0 [ifName] => ippp0 [ifAlias] => [ifType] => ppp ) ) SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '49' ORDER BY port_id[0m] ......... >> Runtime for discovery module 'ports': 0.0720 seconds with 2104 bytes #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '49'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus[0m] >> Runtime for discovery module 'ports-stack': 0.0110 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalEntry = No Such Object available on this agent at this OID entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '49'[0m] >> Runtime for discovery module 'entity-physical': 0.0740 seconds with 2928 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS Device #### Load disco module processors #### hrDevice: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDevice[0m] hrDevice = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad[0m] hrProcessorLoad = No Such Object available on this agent at this OID SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '49' AND `processor_type` != 'ucd-old'[0m] SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '49'[0m] >> Runtime for discovery module 'processors': 0.0390 seconds with 33792 bytes #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '49' AND `mempool_type` = 'cemp'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '49'[0m] >> Runtime for discovery module 'mempools': 0.0860 seconds with 22560 bytes #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '49' [0m] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1544 bytes #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 9 ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 3 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.10.0.0.3[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '49' AND `ifIndex` = '9'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '49' AND `ifIndex` = '9'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.3/32'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '10.0.0.3/32'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.0.3/32'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '10.0.0.3' AND `ipv4_prefixlen` = '32' AND `port_id` = '837' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '10.0.0.3' AND `ipv4_prefixlen` = '32' AND `port_id` = '837'[0m] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '49' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '49' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.0/8'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.0/8'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '829' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '829'[0m] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.192.168.50.150[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '49' AND `ifIndex` = '3'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '49' AND `ifIndex` = '3'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.50.0/24'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '192.168.50.0/24'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.50.0/24'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '192.168.50.150' AND `ipv4_prefixlen` = '24' AND `port_id` = '831' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '192.168.50.150' AND `ipv4_prefixlen` = '24' AND `port_id` = '831'[0m] .SQL[[0;33mSELECT * FROM ipv4_addresses AS A, ports AS I WHERE I.device_id = '49' AND A.port_id = I.port_id[0m] >> Runtime for discovery module 'ipv4-addresses': 0.0860 seconds with 16696 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM ipv6_addresses AS A, ports AS I WHERE I.device_id = '49' AND A.port_id = I.port_id[0m] >> Runtime for discovery module 'ipv6-addresses': 0.0470 seconds with 6624 bytes #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr = No Such Object available on this agent at this OID entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName = No Such Object available on this agent at this OID entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '49' AND `attrib_type` = 'ipmi_hostname' [0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'ipmi'[0m] Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] State: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Temperature: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] Voltage: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '49' AND S.poller_type = 'snmp'[0m] >> Runtime for discovery module 'sensors': 0.1770 seconds with 7760 bytes #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dfEntry[0m] dfEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '49' AND `storage_type` != 'dsk'[0m] SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '49'[0m] >> Runtime for discovery module 'storage': 0.1180 seconds with 3400 bytes #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '49'[0m] >> Runtime for discovery module 'hr-device': 0.0340 seconds with 792 bytes #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID Array ( ) LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemoteSystemsData[0m] lldpRemoteSystemsData = No Such Object available on this agent at this OID lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData || || || Array ( ) SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Array ( ) OSPF Discovery: enabled SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='49'[0m] SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '49'[0m] >> Runtime for discovery module 'discovery-protocols': 0.0760 seconds with 4208 bytes #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress.*.1 = e4:8d:8c:17:b8:1 SQL[[0;33mSELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='49' AND M.context_name=''[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '49' AND `ifIndex` = '3'[0m] >> Runtime for discovery module 'arp-table': 0.0380 seconds with 16672 bytes #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.15.2[0m] No Such Object available on this agent at this OID No BGP on hostPeers : SQL[[0;33mSELECT * FROM bgpPeers WHERE device_id = '49' AND (context_name = '' OR context_name IS NULL)[0m] >> Runtime for discovery module 'bgp-peers': 0.0150 seconds with 2672 bytes #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '49'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0470 seconds with 4320 bytes #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ toner ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '49'[0m] >> Runtime for discovery module 'ucd-diskio': 0.0180 seconds with 736 bytes #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '49'[0m] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0150 seconds with 3648 bytes #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 144 bytes #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '49' AND `attrib_type` = 'poll_mib' [0m] SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='1.538' WHERE `device_id` = '49'[0m] Discovered in 1.538 seconds SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','lg-testucp','1492671433.6698','1.563','1','librenms ')[0m] ./discovery.php lg-testucp 2017-04-20 07:57:15 - 1 devices discovered in 1.563 secs SNMP: Get[9/0.15s] Walk [31/0.70s] MySQL: Cell[20/0.01s] Row[5/0.00s] Rows[38/0.02s] Column[1/0.00s] Update[7/0.00s] Insert[2/0.00s] Delete[0/0.00s]