LibreNMS Discovery SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 0.3ms] SQL[[1;33mselect count(*) as aggregate from `migrations` limit 1 [0;33m[][0m 0.29ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.27ms] =================================== Version info: Commit SHA: 37ac9dffbed58a434a446893d84b4d33ad1d83c0 Commit Date: 1620283571 DB Schema: 2021_04_08_151101_add_foreign_keys_to_port_group_port_table (208) PHP: 7.4.3 MySQL: 10.3.25-MariaDB-0ubuntu0.20.04.1 RRDTool: 1.7.2 SNMP: NET-SNMP 5.8 ==================================DEBUG! Updating os_def.cache SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '192.168.140.254' ORDER BY device_id DESC [0;33m[][0m 1.62ms] SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[24][0m 1.46ms] SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[24][0m 0.61ms] 192.168.140.254 24 bintec SQL[[1;33mselect `hostname`, `overwrite_ip` from `devices` where `hostname` = ? limit 1 [0;33m["192.168.140.254"][0m 0.83ms] [FPING] '/usr/bin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '192.168.140.254' response: {"xmt":3,"rcv":3,"loss":0,"min":16.6,"max":24.0,"avg":19.2,"dup":0,"exitcode":0} SQL[[1;33mselect `device_groups`.*, `device_group_device`.`device_id` as `pivot_device_id`, `device_group_device`.`device_group_id` as `pivot_device_group_id` from `device_groups` inner join `device_group_device` on `device_groups`.`id` = `device_group_device`.`device_group_id` where `device_group_device`.`device_id` = ? [0;33m[24][0m 0.53ms] SQL[[1;33mselect * from `locations` where `locations`.`id` = ? limit 1 [0;33m[15][0m 0.66ms] SQL[[1;33mselect exists(select * from `alert_schedule` where (`start` <= ? and `end` >= ? and (`recurring` = ? or (`recurring` = ? and ((time(`start`) < time xss=removed> ?) or (time(`start`) > time(`end`) and (time(`end`) <= ? or time(`start`) > ?))) and (`recurring_day` like ? or `recurring_day` is null)))) and (exists (select * from `devices` inner join `alert_schedulables` on `devices`.`device_id` = `alert_schedulables`.`alert_schedulable_id` where `alert_schedule`.`schedule_id` = `alert_schedulables`.`schedule_id` and `alert_schedulables`.`alert_schedulable_type` = ? and `alert_schedulables`.`alert_schedulable_id` = ?) or exists (select * from `locations` inner join `alert_schedulables` on `locations`.`id` = `alert_schedulables`.`alert_schedulable_id` where `alert_schedule`.`schedule_id` = `alert_schedulables`.`schedule_id` and `alert_schedulables`.`alert_schedulable_type` = ? and `alert_schedulables`.`alert_schedulable_id` = ?))) as `exists` [0;33m["2021-05-06T13:34:18.043868Z","2021-05-06T13:34:18.043868Z",0,1,"13:34:18","13:34:18","13:34:18","13:34:18","[44m%","device",24,"location",15][0m 2.11ms] SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) [0;33m{"xmt":3,"rcv":3,"loss":0,"min":16.6,"max":24,"avg":19.2,"device_id":24,"debug":"[]"}[0m 5.18ms] SQL[[1;33mUPDATE `devices` set `last_ping`=?,`last_ping_timetaken`=? WHERE device_id=? [0;33m["2021-05-06 15:34:18",19.2,24][0m 3.38ms] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0'[0m] .*.*.0 = P1 NS Plein Tilburg .*.*.0 = .*.4.1.2*.*.0 .*.*.0 = RS353a | RS353a | .1.3.6.1.4.1.272.4.201.82.78.81.48.0.0 | Attempting to initialize OS: bintec OS initialized as Generic OS: Bintec Router (bintec) >> Runtime for discovery module 'core': 0.0390 seconds with 203320 bytes >> SNMP: [2/0.06s] MySQL: [3/0.01s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS Device #### Load disco module os #### Yaml location data: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'[0m] NS Plein 14. Tilburg ::query() failed: DNS request failed: The domain name referenced in the query does not exist. SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'sysContact.0'[0m] KD Telematica 0174441133 Yaml OS data: Location: NS Plein 14. Tilburg Hardware: OS Version: OS Features: Serial: >> Runtime for discovery module 'os': 0.0890 seconds with 519864 bytes >> SNMP: [4/0.07s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifDescr'[0m] Exitcode: 1 Error: OID not increasing: ifDescr.35600000 >= ifDescr.30010001 ifDescr.0 = REFUSE ifDescr.1 = LOCAL ifDescr.2 = IGNORE ifDescr.1000000 = en1-0 ifDescr.1040000 = en1-4 ifDescr.35600000 = efm35-60 ifDescr.30010001 = XS4all Fiber Error: OID not increasing: ifDescr.35600000 >= ifDescr.30010001 SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifName'[0m] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifAlias'[0m] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifType'[0m] Exitcode: 1 Error: OID not increasing: ifType.35600000 >= ifType.30010001 ifType.0 = other ifType.1 = other ifType.2 = other ifType.1000000 = ethernetCsmacd ifType.1040000 = l2vlan ifType.35600000 = ethernetCsmacd ifType.30010001 = ppp Error: OID not increasing: ifType.35600000 >= ifType.30010001 SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifOperStatus'[0m] Exitcode: 1 Error: OID not increasing: ifOperStatus.35600000 >= ifOperStatus.30010001 ifOperStatus.0 = up ifOperStatus.1 = up ifOperStatus.2 = up ifOperStatus.1000000 = up ifOperStatus.1040000 = up ifOperStatus.35600000 = down ifOperStatus.30010001 = up Error: OID not increasing: ifOperStatus.35600000 >= ifOperStatus.30010001 array ( 0 => array ( 'ifDescr' => 'REFUSE', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 1 => array ( 'ifDescr' => 'LOCAL', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 2 => array ( 'ifDescr' => 'IGNORE', 'ifType' => 'other', 'ifOperStatus' => 'up', ), 1000000 => array ( 'ifDescr' => 'en1-0', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 1040000 => array ( 'ifDescr' => 'en1-4', 'ifType' => 'l2vlan', 'ifOperStatus' => 'up', ), 35600000 => array ( 'ifDescr' => 'efm35-60', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'down', ), 30010001 => array ( 'ifDescr' => 'XS4all Fiber', 'ifType' => 'ppp', 'ifOperStatus' => 'up', ), ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[24][0m 2.44ms] Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["REFUSE","other","up",0,"REFUSE","REFUSE",0,970][0m 4.15ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["LOCAL","other","up",1,"LOCAL","LOCAL",0,971][0m 3.64ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["IGNORE","other","up",2,"IGNORE","IGNORE",0,972][0m 6.91ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["en1-0","ethernetCsmacd","up",1000000,"en1-0","en1-0",0,973][0m 14ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["en1-4","l2vlan","up",1040000,"en1-4","en1-4",0,974][0m 4.95ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["efm35-60","ethernetCsmacd","down",35600000,"efm35-60","efm35-60",0,975][0m 5.08ms] U Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=?,`deleted`=? WHERE `port_id` = ? [0;33m["XS4all Fiber","ppp","up",30010001,"XS4all Fiber","XS4all Fiber",0,976][0m 5.3ms] U >> Runtime for discovery module 'ports': 0.6070 seconds with 8840 bytes >> SNMP: [5/0.55s] MySQL: [8/0.05s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '24' [0;33m[][0m 0.8ms] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ifStackStatus'[0m] >> Runtime for discovery module 'ports-stack': 0.0580 seconds with 3192 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m] MIB search path: /opt/librenms/mibs Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 10 in (none) SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[24][0m 1.18ms] >> Runtime for discovery module 'entity-physical': 0.0620 seconds with 6832 bytes >> SNMP: [1/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS Device Module [ entity-state ] disabled globally. Modules status: Global+ OS Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrProcessorLoad'[0m] UCD Resources: SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[24][0m 0.82ms] SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'[0m] Exitcode: 2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: iso.3.6.1.4.1.2021.11.11.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: iso.3.6.1.4.1.2021.11.11.0 SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[24][0m 1.09ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.86ms] >> Runtime for discovery module 'processors': 0.1060 seconds with 106344 bytes >> SNMP: [2/0.09s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrStorageTable'[0m] SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrMemorySize.0'[0m] Exitcode: 2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: HOST-RESOURCES-MIB::hrMemorySize.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: HOST-RESOURCES-MIB::hrMemorySize.0 SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0'[0m] Exitcode: 2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memBuffer.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memCached.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memSysAvail.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailSwap.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memTotalReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memAvailReal.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memBuffer.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memCached.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: memSysAvail.0 SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[24][0m 1.25ms] >> Runtime for discovery module 'mempools': 0.2460 seconds with 90072 bytes >> SNMP: [2/0.18s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[24][0m 0.91ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0030 seconds with 2648 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global- OS Device Module [ cisco-qfp ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m] Exitcode: 1 Error: OID not increasing: ipAdEntIfIndex.192.168.140.254.1 >= ipAdEntIfIndex.80.100.74.202.4 ipAdEntIfIndex.*.0 1000000 ipAdEntIfIndex.*.1 38100001 ipAdEntIfIndex.*.4 30010001 Error: OID not increasing: ipAdEntIfIndex.192.168.140.254.1 >= ipAdEntIfIndex.80.100.74.202.4 SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntNetMask.192.168.140.254.0'[0m] * SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntNetMask.192.168.140.254.1'[0m] * SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAdEntNetMask.80.100.74.202.4'[0m] * SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[24][0m 1.82ms] >> Runtime for discovery module 'ipv4-addresses': 0.2070 seconds with 105992 bytes >> SNMP: [4/0.20s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'[0m] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m] SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[24][0m 1.25ms] >> Runtime for discovery module 'ipv6-addresses': 0.1170 seconds with 3392 bytes >> SNMP: [2/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",24,"ipmi"][0m 2.06ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",24,"ipmi"][0m 1.47ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",24,"ipmi"][0m 1.39ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",24,"ipmi"][0m 1.41ms] Airflow: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",24,"snmp"][0m 1.51ms] Current: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",24,"snmp"][0m 1.56ms] Charge: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",24,"snmp"][0m 0.8ms] Dbm: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",24,"snmp"][0m 0.61ms] Fanspeed: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",24,"snmp"][0m 0.62ms] Frequency: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",24,"snmp"][0m 0.62ms] Humidity: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",24,"snmp"][0m 0.61ms] Load: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",24,"snmp"][0m 0.61ms] Loss: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",24,"snmp"][0m 0.61ms] Power: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",24,"snmp"][0m 0.63ms] Power_consumed: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",24,"snmp"][0m 0.61ms] Power_factor: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",24,"snmp"][0m 0.61ms] Runtime: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",24,"snmp"][0m 0.61ms] Signal: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",24,"snmp"][0m 0.6ms] State: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",24,"snmp"][0m 0.53ms] Count: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",24,"snmp"][0m 0.57ms] Temperature: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",24,"snmp"][0m 0.5ms] Tv_signal: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",24,"snmp"][0m 0.61ms] Voltage: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",24,"snmp"][0m 0.66ms] Snr: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",24,"snmp"][0m 0.57ms] Pressure: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",24,"snmp"][0m 0.57ms] Cooling: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",24,"snmp"][0m 0.56ms] Delay: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",24,"snmp"][0m 0.57ms] Quality_factor: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",24,"snmp"][0m 0.5ms] Chromatic_dispersion: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",24,"snmp"][0m 0.55ms] Ber: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",24,"snmp"][0m 0.56ms] Eer: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",24,"snmp"][0m 0.53ms] Waterflow: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",24,"snmp"][0m 0.56ms] Percent: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",24,"snmp"][0m 0.54ms] >> Runtime for discovery module 'sensors': 0.0980 seconds with 66776 bytes >> SNMP: [1/0.05s] MySQL: [33/0.03s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'aixFsTableEntry'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs Cannot find module (IBM-AIX-MIB): At line 10 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) MIB search path: /opt/librenms/mibs Cannot find module (IBM-AIX-MIB): At line 10 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) aix_filesystem : SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'datasetTable'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs Cannot find module (FREENAS-MIB): At line 10 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) MIB search path: /opt/librenms/mibs Cannot find module (FREENAS-MIB): At line 10 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '24' AND `storage_type` != 'dataset' [0;33m[][0m 0.98ms] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'zpoolTable'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs Cannot find module (FREENAS-MIB): At line 10 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) MIB search path: /opt/librenms/mibs Cannot find module (FREENAS-MIB): At line 10 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '24' AND `storage_type` != 'zpool' [0;33m[][0m 0.73ms] hrStorage : SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dskTable'[0m] SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '24' AND `storage_type` != 'dsk' [0;33m[][0m 1.02ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '24' [0;33m[][0m 1.02ms] >> Runtime for discovery module 'storage': 0.1920 seconds with 21328 bytes >> SNMP: [5/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m] array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '24' [0;33m[][0m 1.08ms] >> Runtime for discovery module 'hr-device': 0.1140 seconds with 3664 bytes >> SNMP: [2/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'cdpCache'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs Cannot find module (CISCO-CDP-MIB): At line 10 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) MIB search path: /opt/librenms/mibs Cannot find module (CISCO-CDP-MIB): At line 10 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) LLDP-MIB: communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'lldpRemTable'[0m] OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[24][0m 1.14ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[24][0m 1.86ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.0850 seconds with 6328 bytes >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipNetToPhysicalPhysAddress'[0m] communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'ipNetToMediaPhysAddress'[0m] Exitcode: 1 Error: OID not increasing: ipNetToMediaPhysAddress[1000000][192.168.140.104].191928 >= ipNetToMediaPhysAddress[1000000][192.168.140.100].191950 ipNetToMediaPhysAddress[1000000][*].191893 = fc:ec:da:4d:be:e3 ipNetToMediaPhysAddress[1000000][*].191928 = 6c:2:e0:92:59:62 ipNetToMediaPhysAddress[1000000][*].191950 = 80:5e:c0:1:62:46 Error: OID not increasing: ipNetToMediaPhysAddress[1000000][192.168.140.104].191928 >= ipNetToMediaPhysAddress[1000000][192.168.140.100].191950 SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[24,""][0m 1.49ms] SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[24,1000000][0m 1.6ms] en1-0: Warning: explode() expects parameter 2 to be string, array given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: array_map(): Expected parameter 2 to be an array, null given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: implode(): Argument must be an array in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Array => 192.168.140.102 Warning: explode() expects parameter 2 to be string, array given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: array_map(): Expected parameter 2 to be an array, null given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: implode(): Argument must be an array in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Array => 192.168.140.104 Warning: explode() expects parameter 2 to be string, array given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: array_map(): Expected parameter 2 to be an array, null given in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Warning: implode(): Argument must be an array in /opt/librenms/includes/discovery/arp-table.inc.php on line 67 Array => 192.168.140.100 SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 1.11ms] >> Runtime for discovery module 'arp-table': 0.1480 seconds with 17064 bytes >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[[0;36m'/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m] 85:5:33:31.18 No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[24,""][0m 0.83ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[24,""][0m 0.67ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[24][0m 0.83ms] >> Runtime for discovery module 'bgp-peers': 0.0450 seconds with 6128 bytes >> SNMP: [1/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[24][0m 0.66ms] SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m] IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m] Exitcode: 2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: Q-BRIDGE-MIB::dot1qVlanVersionNumber.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: Q-BRIDGE-MIB::dot1qVlanVersionNumber.0 >> Runtime for discovery module 'vlans': 0.1100 seconds with 9768 bytes >> SNMP: [2/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ printer-supplies ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'diskIOEntry'[0m] array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '24' [0;33m[][0m 1.03ms] >> Runtime for discovery module 'ucd-diskio': 0.0530 seconds with 3224 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0010 seconds with 768 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[24][0m 0.77ms] SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dStpProtocolSpecification.0'[0m] Exitcode: 2 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: BRIDGE-MIB::dot1dStpProtocolSpecification.0 Error in packet Reason: (noSuchName) There is no such variable name in this MIB. Failed object: BRIDGE-MIB::dot1dStpProtocolSpecification.0 >> Runtime for discovery module 'stp': 0.0400 seconds with 5888 bytes >> SNMP: [1/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0010 seconds with 280 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. Modules status: Global+ OS Device #### Load disco module wireless #### SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"ap-count"][0m 1.35ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"clients"][0m 1.06ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"quality"][0m 0.99ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"capacity"][0m 0.61ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"utilization"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"rate"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"ccq"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"snr"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"sinr"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"rsrp"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"rsrq"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"ssr"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"mse"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"xpi"][0m 0.49ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"rssi"][0m 0.44ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"power"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"noise-floor"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"errors"][0m 0.52ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"error-ratio"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"error-rate"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"frequency"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"distance"][0m 0.4ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"cell"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[24,"channel"][0m 0.48ms] >> Runtime for discovery module 'wireless': 0.0220 seconds with 131584 bytes >> SNMP: [0/0.00s] MySQL: [24/0.02s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[24][0m 0.33ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[24][0m 0.28ms] communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m] communityStringIndexing SNMP[[0;36m'/usr/bin/snmpwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m] >> Runtime for discovery module 'fdb-table': 0.1310 seconds with 2984 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### Modules status: Global+ OS Device #### Load disco module mpls #### >> Runtime for discovery module 'mpls': 0.0020 seconds with 23952 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mpls #### SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[3.707,24][0m 5.69ms] Discovered in 3.707 seconds ./discovery.php 192.168.140.254 2021-05-06 15:34:20 - 1 devices discovered in 3.918 secs SNMP [35/1.88s]: Get[14/0.56s] Getnext[1/0.04s] Walk[20/1.28s] MySQL [91/0.15s]: Cell[1/0.00s] Row[1/0.00s] Rows[70/0.07s] Column[4/0.01s] Update[9/0.06s] Insert[1/0.01s] Delete[5/0.01s] RRD [0/0.00s]: