LibreNMS Discovery SQL[select `migration` from `migrations` order by `id` desc limit 1 [] 3.81ms] SQL[select count(*) as aggregate from `migrations` limit 1 [] 0.4ms] SQL[SELECT version() [] 1.97ms] =================================== Version info: Commit SHA: 21192a9cf2a3226e1a06bf69e5688242c5903dfa Commit Date: 1549635449 DB Schema: 2019_01_16_195644_add_vrf_id_and_bgpLocalAs (131) PHP: 5.6.40-0+deb8u1 MySQL: 10.0.38-MariaDB-0+deb8u1 RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2.1 ==================================DEBUG! Updating os_def.cache... Warning: file_put_contents(/opt/librenms/cache/os_defs.cache): failed to open stream: Permission denied in /opt/librenms/includes/common.php on line 1639 Done SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'caraaoltvolt.netcomet.com.br' ORDER BY device_id DESC [] 9ms] SQL[SELECT * FROM devices_attribs WHERE `device_id` = ? [364] 0.35ms] caraaoltvolt.netcomet.com.br 364 serverscheck [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 caraaoltvolt.netcomet.com.br Array ( [ xmt ] => 3 [ rcv ] => 3 [ loss ] => 0 [ min ] => 8.49 [ max ] => 10.6 [ avg ] => 9.35 [ exitcode] => 0 ) SQL[INSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) {"xmt":"3","rcv":"3","loss":"0","min":"8.49","max":"10.6","avg":"9.35","device_id":364,"debug":"[]"} 4.91ms] SNMP Check response code: 0 SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [364,"poll_mib"] 0.47ms] MIB: registering Attempting to initialize OS: serverscheck OS initialized as Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0'] .*.*.0 = Pop Protect SNMP .*.*.0 = .*.4.1.17095.1 .*.*.0 = Alarme SNMP >> Runtime for discovery module 'core': 0.0470 seconds with 1528 bytes >> SNMP: [2/0.09s] MySQL: [4/0.02s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'SNMPv2-MIB::sysDescr.0'] Alarme SNMP SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'SNMPv2-MIB::sysObjectID.0'] .*.4.1.17095.1 | Alarme SNMP | .1.3.6.1.4.1.17095.1 | SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' '.1.3.6.1.4.1.12148.10.2.6.0'] No Such Object available on this agent at this OID OS: ServersCheck (serverscheck) >> Runtime for discovery module 'os': 0.1050 seconds with 1156 bytes >> SNMP: [3/0.10s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ifDescr'] ifDescr.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ifName'] ifName.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ifAlias'] ifAlias.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ifType'] ifType.0 = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [364] 2.33ms] >> Runtime for discovery module 'ports': 0.5090 seconds with 1904 bytes >> SNMP: [4/0.50s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '364' [] 0.6ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ifStackStatus'] ifStackStatus.0 = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.1150 seconds with 1216 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntry SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'entPhysicalEntry'] entPhysicalEntry.0 = No Such Object available on this agent at this OID SQL[SELECT * FROM `entPhysical` WHERE `device_id` = ? [364] 3.84ms] >> Runtime for discovery module 'entity-physical': 0.1540 seconds with 2012 bytes >> SNMP: [1/0.15s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'hrProcessorLoad'] hrProcessorLoad.0 = No Such Object available on this agent at this OID UCD Resources: SQL[SELECT `devices`.*, `location`, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.location_id=`locations`.`id` WHERE `device_id` = ? [364] 1.74ms] SQL[SELECT * FROM devices_attribs WHERE `device_id` = ? [364] 0.52ms] SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [364] 0.8ms] SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' '.1.3.6.1.4.1.2021.11.11.0'] No Such Object available on this agent at this OID SQL[SELECT * FROM `processors` WHERE `device_id`=? [364] 1.9ms] SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [] 3.34ms] >> Runtime for discovery module 'processors': 0.1820 seconds with 63340 bytes >> SNMP: [2/0.17s] MySQL: [5/0.01s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [364] 0.96ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck:/opt/librenms/mibs/hp' 'udp:HOSTNAME:1161' 'hpLocal'] hpLocalMem.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck:/opt/librenms/mibs/hp' 'udp:HOSTNAME:1161' 'hpGlobal'] hpGlobalMem.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'hrStorageEntry'] hrStorageEntry.0 = No Such Object available on this agent at this OID SQL[SELECT * FROM `mempools` WHERE `device_id` = '364' [] 1.06ms] >> Runtime for discovery module 'mempools': 0.4720 seconds with 20856 bytes >> SNMP: [3/0.46s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = ? [364] 0.59ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 1348 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipAdEntIfIndex'] ipAdEntIfIndex.0 No Such Object available on this agent at this OID SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipAdEntNetMask.'] No Such Object available on this agent at this OID SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [364,null] 1.42ms] ! SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [364] 6.81ms] >> Runtime for discovery module 'ipv4-addresses': 0.2060 seconds with 34548 bytes >> SNMP: [2/0.20s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipAddressIfIndex.ipv6'] ipAddressIfIndex.ipv6."" No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipv6AddrPfxLength'] .*.*.* No Such Object available on this agent at this OID SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [364] 0.95ms] >> Runtime for discovery module 'ipv6-addresses': 0.2380 seconds with 1720 bytes >> SNMP: [2/0.24s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### Pre-cache serverscheck: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'SERVERSCHECK-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'control'] control.0 = No Such Object available on this agent at this OID Array ( [serverscheck_control] => Array ( ) ) ENTITY-SENSOR: Caching OIDs: entPhysicalDescr SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'entPhysicalDescr'] entPhysicalDescr.0 = No Such Object available on this agent at this OID SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [364,"ipmi_hostname"] 1.08ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",364,"ipmi"] 1.7ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",364,"ipmi"] 1.35ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",364,"ipmi"] 0.95ms] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",364,"ipmi"] 0.95ms] Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["airflow",364,"snmp"] 0.83ms] Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["current",364,"snmp"] 1.26ms] Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["charge",364,"snmp"] 1.06ms] Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["dbm",364,"snmp"] 1.1ms] Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["fanspeed",364,"snmp"] 1.15ms] Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["frequency",364,"snmp"] 1ms] Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["humidity",364,"snmp"] 0.78ms] Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["load",364,"snmp"] 1.07ms] Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power",364,"snmp"] 0.76ms] Power_consumed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_consumed",364,"snmp"] 1.03ms] Power_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["power_factor",364,"snmp"] 0.94ms] Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["runtime",364,"snmp"] 0.73ms] Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["signal",364,"snmp"] 1.19ms] State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["state",364,"snmp"] 1.07ms] Count: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["count",364,"snmp"] 1.11ms] Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["temperature",364,"snmp"] 0.84ms] Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["voltage",364,"snmp"] 0.99ms] Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["snr",364,"snmp"] 0.79ms] Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["pressure",364,"snmp"] 1.06ms] Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["cooling",364,"snmp"] 0.9ms] Delay: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["delay",364,"snmp"] 1.31ms] Quality_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["quality_factor",364,"snmp"] 1.15ms] Chromatic_dispersion: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["chromatic_dispersion",364,"snmp"] 0.89ms] Ber: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["ber",364,"snmp"] 0.88ms] Eer: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["eer",364,"snmp"] 1.07ms] Waterflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? ["waterflow",364,"snmp"] 1.18ms] >> Runtime for discovery module 'sensors': 0.3110 seconds with 30120 bytes >> SNMP: [1/0.12s] MySQL: [31/0.04s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:1161' 'fileSystemSpaceTable'] fileSystemSpaceTable.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'hrStorageEntry'] hrStorageEntry.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dskTable'] dskTable.0 = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '364' AND `storage_type` != 'dsk' [] 1.64ms] SQL[SELECT * FROM `storage` WHERE `device_id` = '364' [] 0.71ms] >> Runtime for discovery module 'storage': 0.4680 seconds with 5192 bytes >> SNMP: [3/0.46s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'hrDeviceEntry'] hrDeviceEntry.0 = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'hrProcessorEntry'] hrProcessorEntry.0 = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '364' [] 1.87ms] >> Runtime for discovery module 'hr-device': 0.2600 seconds with 2088 bytes >> SNMP: [2/0.25s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'cdpCache'] cdpCache.0 = No Such Object available on this agent at this OID LLDP-MIB: SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'lldpRemTable'] Timeout: No Response from udp:caraaoltvolt.netcomet.com.br:1161 OSPF Discovery: SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [364] 1.45ms] SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [364] 0.97ms] SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [] 5.67ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 6.1960 seconds with 1132 bytes >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipNetToPhysicalPhysAddress'] ipNetToPhysicalPhysAddress[0] = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'ipNetToMediaPhysAddress'] ipNetToMediaPhysAddress[0] = No Such Object available on this agent at this OID SQL[SELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [364,""] 4.72ms] SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [] 9.43ms] >> Runtime for discovery module 'arp-table': 0.2370 seconds with 1252 bytes >> SNMP: [0/0.00s] MySQL: [2/0.01s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP['/usr/bin/snmpgetnext' '-v2c' '-c' 'COMMUNITY' '-Oqvn' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'bgpLocalAs'] "Alarme SNMP" No BGP on hostPeers : SQL[DELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [364,""] 1.08ms] SQL[DELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [364,""] 0.32ms] SQL[SELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [364] 0.71ms] >> Runtime for discovery module 'bgp-peers': 0.0400 seconds with 2680 bytes >> SNMP: [1/0.04s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = ? [364] 0.66ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dot1dBasePortIfIndex'] dot1dBasePortIfIndex.0 = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dot1qVlanVersionNumber.0'] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.2110 seconds with 4172 bytes >> SNMP: [2/0.21s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'diskIOEntry'] diskIOEntry.0 = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '364' [] 0.9ms] >> Runtime for discovery module 'ucd-diskio': 0.1270 seconds with 1964 bytes >> SNMP: [1/0.13s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 252 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[SELECT * FROM `stp` WHERE `device_id` = ? [364] 0.37ms] SNMP['/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dot1dStpProtocolSpecification.0'] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0320 seconds with 1768 bytes >> SNMP: [1/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 240 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"ap-count"] 1.67ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"clients"] 0.7ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"quality"] 0.76ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"capacity"] 0.59ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"utilization"] 0.56ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"rate"] 0.55ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"ccq"] 0.54ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"snr"] 1.06ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"ssr"] 0.6ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"mse"] 0.51ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"xpi"] 0.54ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"rssi"] 0.53ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"power"] 0.55ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"noise-floor"] 0.69ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"errors"] 0.71ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"error-ratio"] 0.54ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"error-rate"] 0.53ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"frequency"] 0.52ms] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [364,"distance"] 0.52ms] >> Runtime for discovery module 'wireless': 0.0320 seconds with 118888 bytes >> SNMP: [0/0.00s] MySQL: [19/0.02s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [364] 0.61ms] SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = ? [364] 0.63ms] SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dot1qTpFdbPort'] dot1qTpFdbPort[0] = No Such Object available on this agent at this OID SNMP['/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' 'udp:HOSTNAME:1161' 'dot1dTpFdbPort'] dot1dTpFdbPort[.0 = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.2840 seconds with 1616 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [364,"poll_mib"] 0.59ms] SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [364,"poll_mib"] 0.26ms] MIB: registering SNMP['/usr/bin/snmptranslate' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/serverscheck' '-IR' '-m' 'all' '.1.3.6.1.4.1.17095.1'] Unknown object identifier: .1.3.6.1.4.1.17095.1 This doesn't look like a MIB: MIB: Could not find all::.1.3.6.1.4.1.17095.1 SQL[UPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [12.146,364] 8.61ms] Discovered in 12.146 seconds SQL[INSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) {"type":"discover","doing":"caraaoltvolt.netcomet.com.br","start":1550930844.4242,"duration":"13.25","devices":1,"poller":"nms"} 4.03ms] /opt/librenms/discovery.php caraaoltvolt.netcomet.com.br 2019-02-23 11:07:37 - 1 devices discovered in 13.25 secs SNMP [30/3.15s]: Get[9/0.37s] Getnext[1/0.04s] Walk[20/2.74s] MySQL [84/0.15s]: Cell[3/0.00s] Row[3/0.00s] Rows[68/0.10s] Column[2/0.00s] Update[1/0.01s] Insert[2/0.01s] Delete[5/0.02s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]