LibreNMS Discovery =================================== Version info: Commit SHA: 386fea0321a86b197d302629a04d20d480828d6d Commit Date: 1525034560 DB Schema: 247 PHP: 7.2.4-1+ubuntu16.04.1+deb.sury.org+1 MySQL: 10.1.24-MariaDB-1~precise RRDTool: 1.5.5 SNMP: NET-SNMP 5.7.3 ==================================DEBUG! Updating os_def.cache... Done SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.222.0.118' ORDER BY device_id DESC] SQL[SELECT * FROM devices_attribs WHERE `device_id` = '3'] 10.222.0.118 3 linux SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','27.8','38.7','31.5','3',NOW())] SNMP Check response code: 0 SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '3' AND `attrib_type` = 'poll_mib' ] Attempting to initialize OS: linux Attempting to initialize OS: unix OS initilized as Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0] .*.*.0 = router .*.*.0 = .1.3 .*.*.0 = Linux router * #1 Wed Jan 31 14:55:39 CST 2018 mips >> Runtime for discovery module 'core': 0.0770 seconds with 1040 bytes >> SNMP: [2/0.14s] MySQL: [8/0.01s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0] Linux router * #1 Wed Jan 31 14:55:39 CST 2018 mips SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0] .1.3 | Linux router 2.6.32.32 #1 Wed Jan 31 14:55:39 CST 2018 mips | .1.3 | SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m SYNOLOGY-SYSTEM-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/synology udp:HOSTNAME:161 systemStatus.0] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 GANDI-MIB::rxCounter.0] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqnv -m IEEE802dot11-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot11manufacturerName] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -m UBNT-AFLTU-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/ubnt udp:HOSTNAME:161 afLTUFirmwareVersion.0] No Such Object available on this agent at this OID OS: Linux (linux) >> Runtime for discovery module 'os': 6.8500 seconds with 2088 bytes >> SNMP: [8/6.85s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifDescr] ifDescr = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifName] ifName = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifAlias] ifAlias = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifType] ifType = No Such Object available on this agent at this OID Array ( ) SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1'] SQL[SELECT * FROM `ports` WHERE `device_id` = '3' ORDER BY port_id] >> Runtime for discovery module 'ports': 4.2300 seconds with 4000 bytes >> SNMP: [4/4.23s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '3'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifStackStatus] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.1480 seconds with 1720 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalEntry] entPhysicalEntry = No Such Object available on this agent at this OID SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '3'] >> Runtime for discovery module 'entity-physical': 1.1700 seconds with 5136 bytes >> SNMP: [1/1.17s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrProcessorLoad] hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SQL[SELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = '3'] SQL[SELECT * FROM devices_attribs WHERE `device_id` = '3'] SQL[SELECT * FROM `vrf_lite_cisco` WHERE `device_id` = '3'] SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0] No Such Object available on this agent at this OID SQL[SELECT * FROM `processors` WHERE `device_id`='3'] SQL[DELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL] >> Runtime for discovery module 'processors': 2.3400 seconds with 134960 bytes >> SNMP: [2/2.33s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '3' AND `mempool_type` = 'cemp'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal] hpLocalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal] hpGlobalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SQL[SELECT * FROM `mempools` WHERE `device_id` = '3'] >> Runtime for discovery module 'mempools': 2.6250 seconds with 38952 bytes >> SNMP: [3/2.62s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '3' ] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2640 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntIfIndex] ipAdEntIfIndex.* 50 ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 10 ipAdEntIfIndex.* 8 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.10.222.0.118] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '3' AND `ifIndex` = '50'] !SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '3' AND `ifIndex` = '1'] !SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.169.254.9.221] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '3' AND `ifIndex` = '10'] !SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.192.168.15.1] * SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '3' AND `ifIndex` = '8'] !SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '3' OR `ports`.`device_id` IS NULL] >> Runtime for discovery module 'ipv4-addresses': 5.3620 seconds with 41992 bytes >> SNMP: [5/5.36s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAddressIfIndex.ipv6] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipv6AddrPfxLength] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '3' OR `ports`.`device_id` IS NULL] >> Runtime for discovery module 'ipv6-addresses': 1.2700 seconds with 3288 bytes >> SNMP: [2/1.27s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### Pre-cache linux: RaspberryPi SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121] iso.*.1.8*.*.*.*.121 = No Such Object available on this agent at this OID Array ( [raspberry_pi_sensors] => Array ( ) ) ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalDescr] entPhysicalDescr = No Such Object available on this agent at this OID SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '3' AND `attrib_type` = 'ipmi_hostname' ] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'ipmi'] Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Charge: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.1] No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Fanspeed: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmFanSensorsDevice] .*.4.1.2*.1.2 No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='raspberry_freq' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Load: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.8] No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Runtime: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.3] No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Temperature: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmTempSensorsDevice] .*.4.1.2*.1.2 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqve -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3] .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Voltage: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmVoltSensorsDevice] .*.4.1.2*.1.2 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3] .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.4] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.5] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.6] No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.7] No Such Object available on this agent at this OID SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='rasbperry_volts' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Delay: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Quality_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Chromatic_dispersion: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Ber: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Eer: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] Waterflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '3' AND S.poller_type = 'snmp'] >> Runtime for discovery module 'sensors': 15.0100 seconds with 53896 bytes >> SNMP: [15/14.99s] MySQL: [28/0.02s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CPQHOST-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 cpqHoFileSysEntry] cpqHoFileSysEntry = No Such Object available on this agent at this OID HPE ILO4 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dskTable] dskTable = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '3' AND `storage_type` != 'dsk'] SQL[SELECT * FROM `storage` WHERE `device_id` = '3'] >> Runtime for discovery module 'storage': 3.5840 seconds with 8480 bytes >> SNMP: [2/2.42s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrDeviceEntry] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrProcessorEntry] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '3'] >> Runtime for discovery module 'hr-device': 1.5490 seconds with 3656 bytes >> SNMP: [2/1.55s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 cdpCache] cdpCache = No Such Object available on this agent at this OID LLDP-MIB: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lldpRemTable] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[SELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='3'] SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '3'] SQL[DELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 2.4710 seconds with 4704 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipNetToPhysicalPhysAddress] ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipNetToMediaPhysAddress] ipNetToMediaPhysAddress[8][*] = f8:94:c2:7c:5:10 ipNetToMediaPhysAddress[10][*] = 0:10:20:30:40:50 SQL[SELECT * from `ipv4_mac` WHERE `device_id`='3' AND `context_name`=''] SQL[SELECT * FROM `ports` WHERE `device_id` = '3' AND `ifIndex` = '8'] : SQL[SELECT * FROM `ports` WHERE `device_id` = '3' AND `ifIndex` = '10'] : SQL[DELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL] >> Runtime for discovery module 'arp-table': 2.2010 seconds with 3608 bytes >> SNMP: [0/0.00s] MySQL: [4/0.00s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS- Device Module [ bgp-peers ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = '3'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1dBasePortIfIndex] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1qVlanVersionNumber.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 1.3560 seconds with 9088 bytes >> SNMP: [2/1.35s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS+ Device #### Load disco module vmware-vminfo #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m +VMWARE-ROOT-MIB:VMWARE-VMINFO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/vmware udp:HOSTNAME:161 vmwVmTable] vmwVmTable = No Such Object available on this agent at this OID SQL[SELECT id, vmwVmVMID, vmwVmDisplayName FROM vminfo WHERE device_id = '3' AND vm_type='vmware'] >> Runtime for discovery module 'vmware-vminfo': 1.1600 seconds with 3312 bytes >> SNMP: [1/1.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vmware-vminfo #### Modules status: Global- OS+ Device #### Load disco module libvirt-vminfo #### >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds with 1696 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module libvirt-vminfo #### Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 diskIOEntry] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '3'] >> Runtime for discovery module 'ucd-diskio': 1.1490 seconds with 3024 bytes >> SNMP: [1/1.15s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS+ Device #### Load disco module applications #### Applications: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 nsExtendStatus] nsExtendStatus = No Such Object available on this agent at this OID Available: Checking for: SQL[SELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='3' ORDER BY `app_type`] SQL[DELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL] >> Runtime for discovery module 'applications': 1.1400 seconds with 4704 bytes >> SNMP: [1/1.14s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module applications #### Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 288 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS- Device Module [ stp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 136 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='ap-count'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='clients'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='quality'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='capacity'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='utilization'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='rate'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='ccq'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='snr'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='ssr'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='mse'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='rssi'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='power'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='noise-floor'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='errors'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='error-ratio'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='error-rate'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='frequency'] SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='3' AND `sensor_class`='distance'] >> Runtime for discovery module 'wireless': 0.0120 seconds with 120264 bytes >> SNMP: [0/0.00s] MySQL: [18/0.01s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '3'] SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = '3'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1qTpFdbPort] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1dTpFdbPort] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 1.5340 seconds with 2904 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '3' AND `attrib_type` = 'poll_mib' ] SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='56.365' WHERE `device_id` = '3'] Discovered in 56.365 seconds SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','10.222.0.118','1525375143.5694','56.57','1','3bff67b236d6')] /opt/librenms/discovery.php 10.222.0.118 2018-05-03 15:20:00 - 1 devices discovered in 56.57 secs SNMP [51/47.71s]: Get[23/17.70s] Getnext[0/0.00s] Walk[28/30.01s] MySQL [92/0.07s]: Cell[8/0.01s] Row[6/0.00s] Rows[70/0.04s] Column[1/0.00s] Update[1/0.00s] Insert[2/0.01s] Delete[4/0.00s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]