LibreNMS Discovery =================================== Version info: Commit SHA: 701fbbc29b7a25e215032a6435fac72c06094976 Commit Date: 1499057076 DB Schema: 198 PHP: 7.0.18-0ubuntu0.16.04.1 MySQL: 10.0.29-MariaDB-0ubuntu0.16.04.1 RRDTool: 1.5.5 SNMP: NET-SNMP 5.7.3 ==================================DEBUG! SQL[[0;33mSHOW TABLES FROM librenms[0m] DB Schema update started.... SQL[[0;33mSELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1[0m] DB Schema already up to date. SQL[[0;33mSELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'ups' ORDER BY device_id DESC[0m] SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '44'[0m] ups 44 powerwalker SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.73','1.09','0.93','44',NOW())[0m] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Network Management Card for UPS SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.935.10.1 | Network Management Card for UPS | .1.3.6.1.4.1.935.10.1 | >> Runtime for discovery module 'os': 0.1270 seconds with 848 bytes #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = eth0 ifDescr.2 = LOOPBACK SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName[0m] ifName = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias[0m] ifAlias = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd Array ( [1] => Array ( [ifDescr] => eth0 [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => LOOPBACK [ifType] => ethernetCsmacd ) ) SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' ORDER BY port_id[0m] .. >> Runtime for discovery module 'ports': 0.3390 seconds with 2008 bytes #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '44'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus[0m] >> Runtime for discovery module 'ports-stack': 0.0100 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalEntry = No Such Object available on this agent at this OID entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '44'[0m] >> Runtime for discovery module 'entity-physical': 0.2300 seconds with 2928 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS Device #### Load disco module processors #### hrDevice: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDevice[0m] hrDevice = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad[0m] hrProcessorLoad = No Such Object available on this agent at this OID SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '44' AND `processor_type` != 'ucd-old'[0m] SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '44'[0m] >> Runtime for discovery module 'processors': 0.1900 seconds with 36552 bytes #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '44' AND `mempool_type` = 'cemp'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '44'[0m] >> Runtime for discovery module 'mempools': 0.3080 seconds with 24672 bytes #### Unload disco module mempools #### Modules status: Global- OS Device Module [ cisco-vrf-lite ] disabled globally. Modules status: Global+ OS Device #### Load disco module cisco-mac-accounting #### >> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds with 1056 bytes #### Unload disco module cisco-mac-accounting #### Modules status: Global+ OS Device #### Load disco module cisco-pw #### >> Runtime for discovery module 'cisco-pw': 0.0000 seconds with 1416 bytes #### Unload disco module cisco-pw #### Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 2 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '44' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.1/32'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '783' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '783'[0m] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.16.100.30[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '44' AND `ifIndex` = '2'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '2'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.100.0/24'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.16.100.0/24'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.100.0/24'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.16.100.30' AND `ipv4_prefixlen` = '24' AND `port_id` = '784' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.16.100.30' AND `ipv4_prefixlen` = '24' AND `port_id` = '784'[0m] .SQL[[0;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '44' OR `ports`.`device_id` IS NULL[0m] >> Runtime for discovery module 'ipv4-addresses': 0.1460 seconds with 4680 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '44' OR `ports`.`device_id` IS NULL[0m] >> Runtime for discovery module 'ipv6-addresses': 0.1960 seconds with 6752 bytes #### Unload disco module ipv6-addresses #### Modules status: Global+ OS Device #### Load disco module route #### >> Runtime for discovery module 'route': 0.0000 seconds with 1448 bytes #### Unload disco module route #### Modules status: Global+ OS Device #### Load disco module sensors #### Pre-cache powerwalker: upsInputEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputEntry[0m] upsInputFrequency.1 = 500 upsInputVoltage.1 = 242 upsInputCurrent.1 = -1 upsInputTruePower.1 = -1 upsOutputEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputEntry[0m] upsOutputVoltage.1 = 230 upsOutputCurrent.1 = -1 upsOutputPower.1 = -1 upsOutputPercentLoad.1 = 18 Array ( [powerwalker] => Array ( [upsInputFrequency] => Array ( [1] => 500 ) [upsInputVoltage] => Array ( [1] => 242 ) [upsInputCurrent] => Array ( [1] => -1 ) [upsInputTruePower] => Array ( [1] => -1 ) [upsOutputVoltage] => Array ( [1] => 230 ) [upsOutputCurrent] => Array ( [1] => -1 ) [upsOutputPower] => Array ( [1] => -1 ) [upsOutputPercentLoad] => Array ( [1] => 18 ) ) ) ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr = No Such Object available on this agent at this OID entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName = No Such Object available on this agent at this OID entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '44' AND `attrib_type` = 'ipmi_hostname' [0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Current: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryCurrent.0[0m] -1 0.1 Amp DC Discover sensor: .1.3.6.1.2.1.33.1.2.6.0, 1, powerwalker, Battery Current, snmp, 1, 1, , 101 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] .Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.4.1.0, 2, powerwalker, Input Voltage, snmp, 1, 1, , 101 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] .Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.3.1.0, 3, powerwalker, Output Voltage, snmp, 1, 1, , 101 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '3'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '3'[0m] .Array ( [powerwalker] => Array ( [1] => 1 [2] => 1 [3] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 1 -> powerwalker 2 -> powerwalker 3 -> powerwalker Charge: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsEstimatedChargeRemaining.0[0m] 100 percent Discover sensor: .1.3.6.1.2.1.33.1.2.4.0, 1, powerwalker, Battery charge remaining, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'charge' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'charge' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] .Array ( [powerwalker] => Array ( [1] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 1 -> powerwalker Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Frequency: PowerWalker Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.2.1, 2, powerwalker, Input Voltage, snmp, 1, 1, , 100 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] .Array ( [powerwalker] => Array ( [2] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 2 -> powerwalker Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] Runtime: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsEstimatedMinutesRemaining.0[0m] 41 minutes Discover sensor: .1.3.6.1.2.1.33.1.2.3.0, 1, powerwalker, Battery time remaining, snmp, 1, 1, , 41 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] .Array ( [powerwalker] => Array ( [1] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 1 -> powerwalker Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] State: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryStatus.0[0m] 2 SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'upsBatteryStatus' LIMIT 1[0m] SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '920'[0m] Discover sensor: .1.3.6.1.2.1.33.1.2.1.0, 0, upsBatteryStatus, Battery Status, snmp, 1, 1, 0, SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '44' AND sensor_type = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '44' AND `sensor_type` = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] .SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '44' AND `sensor_type` = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'upsBatteryStatus'[0m] SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('790','920')[0m] Array ( [upsBatteryStatus] => Array ( [0] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 0 -> upsBatteryStatus Temperature: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryTemperature.0[0m] 28 degrees Centigrade Discover sensor: .1.3.6.1.2.1.33.1.2.7.0, 1, powerwalker, Ambient Temperature, snmp, 1, 1, , 28 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] .Array ( [powerwalker] => Array ( [1] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 1 -> powerwalker Voltage: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryVoltage.0[0m] 2054 0.1 Volt DC Discover sensor: .1.3.6.1.2.1.33.1.2.5.0, 1, powerwalker, Battery Voltage, snmp, 1, 1, , 205401 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] .Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.3.1, 2, powerwalker, Input Voltage, snmp, 1, 1, , 205401 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] .Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.2.1, 3, powerwalker, Output Voltage, snmp, 1, 1, , 205401 SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '3'[0m] SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '3'[0m] .Array ( [powerwalker] => Array ( [1] => 1 [2] => 1 [3] => 1 ) ) SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 1 -> powerwalker 2 -> powerwalker 3 -> powerwalker Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] >> Runtime for discovery module 'sensors': 0.9540 seconds with 11344 bytes #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dfEntry[0m] dfEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '44' AND `storage_type` != 'dsk'[0m] SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '44'[0m] >> Runtime for discovery module 'storage': 0.3630 seconds with 3232 bytes #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '44'[0m] >> Runtime for discovery module 'hr-device': 0.1890 seconds with 792 bytes #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID Array ( ) LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemoteSystemsData[0m] lldpRemoteSystemsData = No Such Object available on this agent at this OID lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData || || || Array ( ) SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Array ( ) OSPF Discovery: enabled SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='44'[0m] xSQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '44'[0m] >> Runtime for discovery module 'discovery-protocols': 0.2720 seconds with 4504 bytes #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress.1 = 0 ipNetToPhysicalPhysAddress.2 = 0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress.*.22 = e4:8d:8c:17:b8:0 ipNetToMediaPhysAddress.*.85 = 0:15:5d:32:60:13 SQL[[0;33mSELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='44' AND M.context_name=''[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '2'[0m] SQL[[0;33mDELETE FROM `ipv4_mac` WHERE `port_id` = '784' AND `mac_address`='00155d65a909' AND `ipv4_address`='172.16.100.83' AND `context_name`=''[0m] SQL[[0;33mDELETE `ipv4_mac` FROM `ipv4_mac` LEFT JOIN `ports` ON `ipv4_mac`.`port_id` = `ports`.`port_id` WHERE `ports`.`port_id` IS NULL[0m] >> Runtime for discovery module 'arp-table': 0.1870 seconds with 32368 bytes #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global+ OS Device #### Load disco module junose-atm-vp #### >> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds with 488 bytes #### Unload disco module junose-atm-vp #### Modules status: Global- OS Device Module [ bgp-peers ] disabled globally. Modules status: Global+ OS Device #### Load disco module vlans #### SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '44'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.1270 seconds with 4352 bytes #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global+ OS Device #### Load disco module libvirt-vminfo #### >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds with 2232 bytes #### Unload disco module libvirt-vminfo #### Modules status: Global+ OS Device #### Load disco module toner #### Checking valid toner ... Array ( ) SQL[[0;33mSELECT * FROM toner WHERE device_id = '44'[0m] Array ( ) >> Runtime for discovery module 'toner': 0.0000 seconds with 1264 bytes #### Unload disco module toner #### Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '44'[0m] >> Runtime for discovery module 'ucd-diskio': 0.0780 seconds with 864 bytes #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '44'[0m] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0290 seconds with 3648 bytes #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 9.3930 seconds with 144 bytes #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. Modules status: Global+ OS Device #### Load disco module wireless #### Attempting to initialize OS: powerwalker SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='ap-count'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='clients'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='quality'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='capacity'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='utilization'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='rate'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='ccq'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='snr'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='rssi'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='power'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='noise-floor'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='error-ratio'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='error-rate'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='frequency'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='distance'[0m] >> Runtime for discovery module 'wireless': 0.0100 seconds with 131256 bytes #### Unload disco module wireless #### Modules status: Global+ OS Device #### Load disco module fdb-table #### SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '44'[0m] SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '44'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.1920 seconds with 2136 bytes #### Unload disco module fdb-table #### Modules status: Global+ OS Device #### Load disco module charge #### >> Runtime for discovery module 'charge': 5.1970 seconds with 96 bytes #### Unload disco module charge #### SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '44' AND `attrib_type` = 'poll_mib' [0m] SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='4.386' WHERE `device_id` = '44'[0m] Discovered in 4.386 seconds SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','ups','1499074932.9853','4.411','1','librenms\n')[0m] ./discovery.php ups 2017-07-03 10:42:17 - 1 devices discovered in 4.411 secs SNMP: Get[13/0.34s] Walk [32/2.97s] MySQL: Cell[27/0.01s] Row[19/0.01s] Rows[57/0.03s] Column[1/0.00s] Update[5/0.00s] Insert[3/0.00s] Delete[1/0.00s]