LibreNMS Discovery =================================== Version info: Commit SHA: cdd363f29ebcdb361ca207a379ff9fd450608d62 Commit Date: 1493244515 DB Schema: 186 PHP: 7.0.17 MySQL: 5.5.52-MariaDB RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! SQL[SELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1] DB Schema already up to date. SQL[SELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'nbhs-tera' ORDER BY device_id DESC] SQL[SELECT * FROM devices_attribs WHERE `device_id` = '285'] nbhs-tera 285 buffalo SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.24','0.27','0.25','285',NOW())] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module os #### SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0] BUFFALO TeraStation TS3400D Ver.1.71 (2017/03/07 12:03:05) SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0] .*.4.1.8* | BUFFALO TeraStation TS3400D Ver.1.71 (2017/03/07 12:03:05) | .1.3.6.1.4.1.8072.3.2.10 | >> Runtime for discovery module 'os': 0.0800 seconds with 920 bytes #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr] ifDescr = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName] ifName = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias] ifAlias = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType] ifType = No Such Object available on this agent at this OID Array ( ) SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1'] SQL[SELECT * FROM `ports` WHERE `device_id` = '285' ORDER BY port_id] >> Runtime for discovery module 'ports': 3.1990 seconds with 1864 bytes #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[SELECT * FROM `ports_stack` WHERE `device_id` = '285'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0370 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry] entPhysicalEntry = No Such Object available on this agent at this OID entAliasMappingIdentifierSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[SELECT * FROM `entPhysical` WHERE `device_id` = '285'] >> Runtime for discovery module 'entity-physical': 0.0600 seconds with 2928 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS Device #### Load disco module processors #### hrDevice: SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDevice] hrDevice = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad] hrProcessorLoad = No Such Object available on this agent at this OID SQL[SELECT COUNT(*) FROM `processors` WHERE `device_id` = '285' AND `processor_type` != 'ucd-old'] SQL[SELECT * FROM `processors` WHERE `device_id` = '285'] >> Runtime for discovery module 'processors': 0.0540 seconds with 34256 bytes #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### SQL[SELECT COUNT(*) FROM `mempools` WHERE `device_id` = '285' AND `mempool_type` = 'cemp'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal] hpLocalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal] hpGlobalMem = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SQL[SELECT * FROM `mempools` WHERE `device_id` = '285'] >> Runtime for discovery module 'mempools': 0.0840 seconds with 22824 bytes #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '285' ] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1544 bytes #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ cisco-vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex] ipAdEntIfIndex No Such Object available on this agent at this OID SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.] No Such Object available on this agent at this OID SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '285' AND `ifIndex` = ''] !SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '285' OR `ports`.`device_id` IS NULL] >> Runtime for discovery module 'ipv4-addresses': 0.0580 seconds with 10888 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '285' OR `ports`.`device_id` IS NULL] >> Runtime for discovery module 'ipv6-addresses': 0.0460 seconds with 1216 bytes #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device+ #### Load disco module route #### >> Runtime for discovery module 'route': 0.0000 seconds with 1368 bytes #### Unload disco module route #### Modules status: Global+ OS Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr] entPhysicalDescr = No Such Object available on this agent at this OID entPhysicalNameSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName] entPhysicalName = No Such Object available on this agent at this OID entPhySensorTypeSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue] entPhySensorValue = No Such Object available on this agent at this OID SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '285' AND `attrib_type` = 'ipmi_hostname' ] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'ipmi'] SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'ipmi'] Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Current: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Charge: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Frequency: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Load: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Power: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Runtime: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] State: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Temperature: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] Voltage: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '285' AND S.poller_type = 'snmp'] >> Runtime for discovery module 'sensors': 0.1460 seconds with 13136 bytes #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry] hrStorageEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dfEntry] dfEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable] dskTable = No Such Object available on this agent at this OID SQL[SELECT `storage_descr` FROM `storage` WHERE `device_id` = '285' AND `storage_type` != 'dsk'] SQL[SELECT * FROM `storage` WHERE `device_id` = '285'] >> Runtime for discovery module 'storage': 0.1270 seconds with 3232 bytes #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `hrDevice` WHERE `device_id` = '285'] >> Runtime for discovery module 'hr-device': 0.0480 seconds with 832 bytes #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: OSPF Discovery: disabled SQL[SELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '285'] >> Runtime for discovery module 'discovery-protocols': 0.0010 seconds with 4208 bytes #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress] ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress] ipNetToMediaPhysAddress = No Such Object available on this agent at this OID SQL[SELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='285' AND M.context_name=''] SQL[DELETE `ipv4_mac` FROM `ipv4_mac` LEFT JOIN `ports` ON `ipv4_mac`.`port_id` = `ports`.`port_id` WHERE `ports`.`port_id` IS NULL] >> Runtime for discovery module 'arp-table': 0.0560 seconds with 800 bytes #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device+ #### Load disco module junose-atm-vp #### >> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds with 488 bytes #### Unload disco module junose-atm-vp #### Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.15.2] No Such Object available on this agent at this OID No BGP on hostPeers : SQL[SELECT * FROM bgpPeers WHERE device_id = '285' AND (context_name = '' OR context_name IS NULL)] >> Runtime for discovery module 'bgp-peers': 2.8770 seconds with 2768 bytes #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[SELECT * FROM `vlans` WHERE `device_id` = '285'] SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.0560 seconds with 4320 bytes #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device+ #### Load disco module libvirt-vminfo #### >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds with 2232 bytes #### Unload disco module libvirt-vminfo #### Modules status: Global- OS Device Module [ toner ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[SELECT * FROM `ucd_diskio` where `device_id` = '285'] >> Runtime for discovery module 'ucd-diskio': 0.0230 seconds with 736 bytes #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[SELECT * FROM `stp` WHERE `device_id` = '285'] SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0210 seconds with 3648 bytes #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 8.7970 seconds with 144 bytes #### Unload disco module ntp #### Modules status: Global- OS Device+ #### Load disco module loadbalancers #### >> Runtime for discovery module 'loadbalancers': 5.0060 seconds with 160 bytes #### Unload disco module loadbalancers #### Modules status: Global- OS Device+ #### Load disco module mef #### SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m MEF-UNI-EVC-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 MefServiceEvcCfgEntry] mefServiceEvcCfgEntry = No Such Object available on this agent at this OID MEF : SQL[SELECT id, mefID, mefIdent FROM mefinfo WHERE device_id = '285'] >> Runtime for discovery module 'mef': 0.0330 seconds with 1456 bytes #### Unload disco module mef #### SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '285' AND `attrib_type` = 'poll_mib' ] SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='7.475' WHERE `device_id` = '285'] Discovered in 7.475 seconds SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','nbhs-tera','1493311304.5902','7.514','1','nms.nbisd.edu\n')] /opt/librenms/discovery.php nbhs-tera 2017-04-27 11:41:52 - 1 devices discovered in 7.514 secs SNMP: Get[6/0.18s] Walk [31/6.75s] MySQL: Cell[6/0.00s] Row[4/0.00s] Rows[38/0.03s] Column[1/0.00s] Update[1/0.01s] Insert[2/0.02s] Delete[0/0.00s]