LibreNMS Discovery SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.27ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.15ms] =================================== Version info: Commit SHA: 29f8a8d4a31897832027358a36ad335a0df3fc19 Commit Date: 1547319112 DB Schema: 281 PHP: 7.2.10-0ubuntu0.18.04.1 MySQL: 10.1.34-MariaDB-0ubuntu0.18.04.1 RRDTool: 1.7.0 SNMP: NET-SNMP 5.7.3 ==================================DEBUG! Updating os_def.cache... Done SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'phy-ruckus' ORDER BY device_id DESC [0;33m[][0m 0.75ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[100][0m 0.18ms] phy-ruckus 100 ruckuswireless [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 phy-ruckus Array ( [xmt] => 3 [rcv] => 3 [loss] => 0 [min] => 4.23 [max] => 57.6 [avg] => 23.5 [exitcode] => 0 ) SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"4.23","max":"57.6","avg":"23.5","device_id":100,"debug":"[]"}[0m 1.79ms] SNMP Check response code: 0 SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[100,"poll_mib"][0m 0.35ms] Attempting to initialize OS: ruckuswireless OS initialized: LibreNMS\OS\Ruckuswireless Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0'[0m] .*.*.0 = Phylax .*.*.0 = .*.4.1.25*.15 .*.*.0 = Ruckus Wireless R510 >> Runtime for discovery module 'core': 0.1230 seconds with 976 bytes >> SNMP: [2/0.17s] MySQL: [4/0.00s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysDescr.0'[0m] Ruckus Wireless R510 SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovqn' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0'[0m] .*.4.1.25*.15 | Ruckus Wireless R510 | .1.3.6.1.4.1.25053.3.1.5.15 | SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.12148.10.2.6.0'[0m] No Such Object available on this agent at this OID OS: Ruckus Wireless (ruckuswireless) >> Runtime for discovery module 'os': 0.1330 seconds with 1336 bytes >> SNMP: [3/0.13s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ifDescr'[0m] ifDescr.1 = lo ifDescr.2 = tif0 ifDescr.3 = eth0 ifDescr.4 = eth1 ifDescr.5 = wifi0 ifDescr.6 = wifi1 ifDescr.7 = wlan102 ifDescr.8 = wlan103 ifDescr.9 = br_ccd ifDescr.10 = br0 ifDescr.11 = br1 ifDescr.12 = br5 ifDescr.13 = br6 ifDescr.14 = br7 ifDescr.15 = br14 ifDescr.16 = vif1 ifDescr.17 = uif1 ifDescr.18 = cif0 ifDescr.19 = wlan0 ifDescr.20 = wlan1 ifDescr.21 = wlan32 ifDescr.22 = wlan33 ifDescr.25 = dhcp0 ifDescr.26 = wlan0 ifDescr.27 = wlan1 ifDescr.28 = wlan32 ifDescr.29 = wlan33 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ifName'[0m] ifName.1 = lo ifName.2 = tif0 ifName.3 = eth0 ifName.4 = eth1 ifName.5 = wifi0 ifName.6 = wifi1 ifName.7 = wlan102 ifName.8 = wlan103 ifName.9 = br_ccd ifName.10 = br0 ifName.11 = br1 ifName.12 = br5 ifName.13 = br6 ifName.14 = br7 ifName.15 = br14 ifName.16 = vif1 ifName.17 = uif1 ifName.18 = cif0 ifName.19 = wlan0 ifName.20 = wlan1 ifName.21 = wlan32 ifName.22 = wlan33 ifName.25 = dhcp0 ifName.26 = wlan0 ifName.27 = wlan1 ifName.28 = wlan32 ifName.29 = wlan33 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ifAlias'[0m] ifAlias.1 = ifAlias.2 = ifAlias.3 = ifAlias.4 = ifAlias.5 = ifAlias.6 = ifAlias.7 = ifAlias.8 = ifAlias.9 = ifAlias.10 = ifAlias.11 = ifAlias.12 = ifAlias.13 = ifAlias.14 = ifAlias.15 = ifAlias.16 = ifAlias.17 = ifAlias.18 = ifAlias.19 = ifAlias.20 = ifAlias.21 = ifAlias.22 = ifAlias.25 = ifAlias.26 = ifAlias.27 = ifAlias.28 = ifAlias.29 = SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ifType'[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.5 = other ifType.6 = other ifType.7 = ethernetCsmacd ifType.8 = ethernetCsmacd ifType.9 = ethernetCsmacd ifType.10 = ethernetCsmacd ifType.11 = ethernetCsmacd ifType.12 = ethernetCsmacd ifType.13 = ethernetCsmacd ifType.14 = ethernetCsmacd ifType.15 = ethernetCsmacd ifType.16 = ethernetCsmacd ifType.17 = ethernetCsmacd ifType.18 = ethernetCsmacd ifType.19 = ethernetCsmacd ifType.20 = ethernetCsmacd ifType.21 = ethernetCsmacd ifType.22 = ethernetCsmacd ifType.25 = ethernetCsmacd ifType.26 = ethernetCsmacd ifType.27 = ethernetCsmacd ifType.28 = ethernetCsmacd ifType.29 = ethernetCsmacd Array ( [1] => Array ( [ifDescr] => lo [ifName] => lo [ifAlias] => [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => tif0 [ifName] => tif0 [ifAlias] => [ifType] => ethernetCsmacd ) [3] => Array ( [ifDescr] => eth0 [ifName] => eth0 [ifAlias] => [ifType] => ethernetCsmacd ) [4] => Array ( [ifDescr] => eth1 [ifName] => eth1 [ifAlias] => [ifType] => ethernetCsmacd ) [5] => Array ( [ifDescr] => wifi0 [ifName] => wifi0 [ifAlias] => [ifType] => other ) [6] => Array ( [ifDescr] => wifi1 [ifName] => wifi1 [ifAlias] => [ifType] => other ) [7] => Array ( [ifDescr] => wlan102 [ifName] => wlan102 [ifAlias] => [ifType] => ethernetCsmacd ) [8] => Array ( [ifDescr] => wlan103 [ifName] => wlan103 [ifAlias] => [ifType] => ethernetCsmacd ) [9] => Array ( [ifDescr] => br_ccd [ifName] => br_ccd [ifAlias] => [ifType] => ethernetCsmacd ) [10] => Array ( [ifDescr] => br0 [ifName] => br0 [ifAlias] => [ifType] => ethernetCsmacd ) [11] => Array ( [ifDescr] => br1 [ifName] => br1 [ifAlias] => [ifType] => ethernetCsmacd ) [12] => Array ( [ifDescr] => br5 [ifName] => br5 [ifAlias] => [ifType] => ethernetCsmacd ) [13] => Array ( [ifDescr] => br6 [ifName] => br6 [ifAlias] => [ifType] => ethernetCsmacd ) [14] => Array ( [ifDescr] => br7 [ifName] => br7 [ifAlias] => [ifType] => ethernetCsmacd ) [15] => Array ( [ifDescr] => br14 [ifName] => br14 [ifAlias] => [ifType] => ethernetCsmacd ) [16] => Array ( [ifDescr] => vif1 [ifName] => vif1 [ifAlias] => [ifType] => ethernetCsmacd ) [17] => Array ( [ifDescr] => uif1 [ifName] => uif1 [ifAlias] => [ifType] => ethernetCsmacd ) [18] => Array ( [ifDescr] => cif0 [ifName] => cif0 [ifAlias] => [ifType] => ethernetCsmacd ) [19] => Array ( [ifDescr] => wlan0 [ifName] => wlan0 [ifAlias] => [ifType] => ethernetCsmacd ) [20] => Array ( [ifDescr] => wlan1 [ifName] => wlan1 [ifAlias] => [ifType] => ethernetCsmacd ) [21] => Array ( [ifDescr] => wlan32 [ifName] => wlan32 [ifAlias] => [ifType] => ethernetCsmacd ) [22] => Array ( [ifDescr] => wlan33 [ifName] => wlan33 [ifAlias] => [ifType] => ethernetCsmacd ) [25] => Array ( [ifDescr] => dhcp0 [ifName] => dhcp0 [ifAlias] => [ifType] => ethernetCsmacd ) [26] => Array ( [ifDescr] => wlan0 [ifName] => wlan0 [ifAlias] => [ifType] => ethernetCsmacd ) [27] => Array ( [ifDescr] => wlan1 [ifName] => wlan1 [ifAlias] => [ifType] => ethernetCsmacd ) [28] => Array ( [ifDescr] => wlan32 [ifName] => wlan32 [ifAlias] => [ifType] => ethernetCsmacd ) [29] => Array ( [ifDescr] => wlan33 [ifName] => wlan33 [ifAlias] => [ifType] => ethernetCsmacd ) ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[100][0m 1.02ms] SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["softwareLoopback","lo","lo","lo",2529][0m 5.08ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","tif0","tif0","tif0",2530][0m 8.79ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","eth0","eth0","eth0",2531][0m 8.74ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","eth1","eth1","eth1",2532][0m 8.8ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["other","wifi0","wifi0","wifi0",2533][0m 8.69ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["other","wifi1","wifi1","wifi1",2534][0m 19.45ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan102","wlan102","wlan102",2535][0m 8.6ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan103","wlan103","wlan103",2536][0m 9.1ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br_ccd","br_ccd","br_ccd",2537][0m 8.69ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br0","br0","br0",2538][0m 8.36ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br1","br1","br1",2539][0m 8.68ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br5","br5","br5",2540][0m 8.67ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br6","br6","br6",2541][0m 9.19ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br7","br7","br7",2542][0m 8.61ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","br14","br14","br14",2543][0m 8.85ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","vif1","vif1","vif1",2544][0m 8.96ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","uif1","uif1","uif1",2545][0m 8.61ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","cif0","cif0","cif0",2546][0m 15.83ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan0","wlan0","wlan0",2556][0m 8.77ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan1","wlan1","wlan1",2557][0m 8.9ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan32","wlan32","wlan32",2552][0m 8.6ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan33","wlan33","wlan33",2553][0m 8.56ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","dhcp0","dhcp0","dhcp0",2547][0m 8.61ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan0","wlan0","wlan0",2548][0m 8.89ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan1","wlan1","wlan1",2549][0m 10.14ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan32","wlan32","wlan32",2550][0m 8.52ms] .SQL[[1;33mUPDATE `ports` set `ifType`=?,`ifName`=?,`ifAlias`=?,`ifDescr`=? WHERE `port_id` = ? [0;33m["ethernetCsmacd","wlan33","wlan33","wlan33",2551][0m 8.45ms] . >> Runtime for discovery module 'ports': 0.7160 seconds with 4248 bytes >> SNMP: [4/0.46s] MySQL: [28/0.26s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '100' [0;33m[][0m 0.19ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ifStackStatus'[0m] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0640 seconds with 1688 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m] entPhysicalEntry = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[100][0m 0.38ms] >> Runtime for discovery module 'entity-physical': 0.0570 seconds with 14288 bytes >> SNMP: [1/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### Caching data: processors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OteQUs' '-Ih' '-m' 'RUCKUS-ZD-SYSTEM-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ruckusZDSystemCPUUtil'[0m] ruckusZDSystemCPUUtil = No Such Object available on this agent at this OID YAML Discovery Data: Array ( [data] => Array ( [0] => Array ( [oid] => ruckusZDSystemCPUUtil [num_oid] => .1.3.6.1.4.1.25053.1.2.1.1.1.5.58.0 [type] => ruckuszd ) ) ) Data ruckusZDSystemCPUUtil: Array ( ) Host Resources: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'hrProcessorLoad'[0m] hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SQL[[1;33mSELECT `devices`.*, `location`, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.location_id=`locations`.`id` WHERE `device_id` = ? [0;33m[100][0m 0.68ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[100][0m 0.17ms] SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[100][0m 0.18ms] SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'[0m] No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[100][0m 0.5ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.4ms] >> Runtime for discovery module 'processors': 0.1650 seconds with 162456 bytes >> SNMP: [3/0.16s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[100][0m 0.28ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus:/opt/librenms/mibs/hp' 'udp:HOSTNAME:161' 'hpLocal'[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'NETSWITCH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus:/opt/librenms/mibs/hp' 'udp:HOSTNAME:161' 'hpGlobal'[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'hrStorageEntry'[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '100' [0;33m[][0m 0.86ms] >> Runtime for discovery module 'mempools': 0.2130 seconds with 28224 bytes >> SNMP: [3/0.21s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[100][0m 0.35ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2624 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m] ipAdEntIfIndex.* 10 ipAdEntIfIndex.* 10 ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 15 ipAdEntIfIndex.* 10 ipAdEntIfIndex.* 13 ipAdEntIfIndex.* 11 SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.62.33.241'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.49ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.24ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.62.33.241\/24"][0m 0.16ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.62.33.241\/24"][0m 1.79ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.62.33.241\/24"][0m 0.14ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["10.62.33.241",24,2538][0m 0.16ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.62.33.241",24,2538][0m 8.43ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.10.62.33.245'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.54ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.34ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.62.33.245\/24"][0m 0.32ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"10.62.33.245\/24"][0m 2.11ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["10.62.33.245\/24"][0m 0.3ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["10.62.33.245",24,2538][0m 0.31ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"10.62.33.245",24,2538][0m 7.01ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.127.0.0.1'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"1"][0m 0.58ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"1"][0m 0.51ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/8"][0m 0.32ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"127.0.0.1\/8"][0m 2.05ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["127.0.0.1\/8"][0m 0.14ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["127.0.0.1",8,2529][0m 0.15ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"127.0.0.1",8,2529][0m 7.71ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.169.254.1.1'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"15"][0m 0.42ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"15"][0m 0.24ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.1.1\/16"][0m 0.15ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"169.254.1.1\/16"][0m 1.48ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.1.1\/16"][0m 0.16ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["169.254.1.1",16,2543][0m 0.17ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"169.254.1.1",16,2543][0m 8.67ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.169.254.17.11'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.58ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.48ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.11\/24"][0m 0.26ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"169.254.17.11\/24"][0m 8.13ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.11\/24"][0m 0.14ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["169.254.17.11",24,2538][0m 0.15ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"169.254.17.11",24,2538][0m 8.19ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.169.254.17.12'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"13"][0m 0.56ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"13"][0m 0.42ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.12\/24"][0m 0.36ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"169.254.17.12\/24"][0m 2.21ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.12\/24"][0m 0.26ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["169.254.17.12",24,2541][0m 0.27ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"169.254.17.12",24,2541][0m 7.89ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAdEntNetMask.169.254.17.13'[0m] * SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"11"][0m 0.83ms] SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,"11"][0m 0.53ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.13\/24"][0m 0.32ms] SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"169.254.17.13\/24"][0m 3.84ms] sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["169.254.17.13\/24"][0m 0.31ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["169.254.17.13",24,2539][0m 0.3ms] SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"169.254.17.13",24,2539][0m 8.08ms] .SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[100][0m 1.51ms] >> Runtime for discovery module 'ipv4-addresses': 0.5250 seconds with 34504 bytes >> SNMP: [8/0.43s] MySQL: [15/0.08s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m] .*.*.* 128 .*.*.* 64 .*.*.* 64 SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovq' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'IPV6-MIB::ipv6AddrType.1'[0m] stateful SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"1"][0m 0.36ms] SQL[[1;33mSELECT port_id FROM `ports` WHERE device_id = ? AND ifIndex = ? [0;33m[100,"1"][0m 0.31ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_networks` WHERE `ipv6_network` = ? [0;33m["::\/128"][0m 0.17ms] SQL[[1;33mUPDATE `ipv6_networks` set `context_name`=? WHERE `ipv6_network` = ? [0;33m[null,"::\/128"][0m 1.59ms] nSQL[[1;33mSELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = ? AND `context_name` = ? [0;33m["::\/128",null][0m 0.14ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_addresses` WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m["0000:0000:0000:0000:0000:0000:0000:0000","128",2529][0m 0.16ms] SQL[[1;33mUPDATE `ipv6_addresses` set `context_name`=? WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m[null,"0000:0000:0000:0000:0000:0000:0000:0000","128",2529][0m 8.29ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovq' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'IPV6-MIB::ipv6AddrType.10'[0m] stateful SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"10"][0m 0.36ms] SQL[[1;33mSELECT port_id FROM `ports` WHERE device_id = ? AND ifIndex = ? [0;33m[100,"10"][0m 0.3ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_networks` WHERE `ipv6_network` = ? [0;33m["::\/64"][0m 0.15ms] SQL[[1;33mUPDATE `ipv6_networks` set `context_name`=? WHERE `ipv6_network` = ? [0;33m[null,"::\/64"][0m 1.22ms] nSQL[[1;33mSELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = ? AND `context_name` = ? [0;33m["::\/64",null][0m 0.15ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_addresses` WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m["0000:0000:0000:0000:0000:0000:0000:0000","64",2538][0m 0.16ms] SQL[[1;33mUPDATE `ipv6_addresses` set `context_name`=? WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m[null,"0000:0000:0000:0000:0000:0000:0000:0000","64",2538][0m 7.75ms] .SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Ovq' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'IPV6-MIB::ipv6AddrType.13'[0m] stateful SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[100,"13"][0m 0.31ms] SQL[[1;33mSELECT port_id FROM `ports` WHERE device_id = ? AND ifIndex = ? [0;33m[100,"13"][0m 0.29ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_networks` WHERE `ipv6_network` = ? [0;33m["::\/64"][0m 0.16ms] SQL[[1;33mUPDATE `ipv6_networks` set `context_name`=? WHERE `ipv6_network` = ? [0;33m[null,"::\/64"][0m 1.39ms] nSQL[[1;33mSELECT `ipv6_network_id` FROM `ipv6_networks` WHERE `ipv6_network` = ? AND `context_name` = ? [0;33m["::\/64",null][0m 0.15ms] SQL[[1;33mSELECT COUNT(*) FROM `ipv6_addresses` WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m["0000:0000:0000:0000:0000:0000:0000:0000","64",2541][0m 0.15ms] SQL[[1;33mUPDATE `ipv6_addresses` set `context_name`=? WHERE `ipv6_address` = ? AND `ipv6_prefixlen` = ? AND `port_id` = ? [0;33m[null,"0000:0000:0000:0000:0000:0000:0000:0000","64",2541][0m 7.85ms] .SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[100][0m 0.35ms] >> Runtime for discovery module 'ipv6-addresses': 0.2970 seconds with 21944 bytes >> SNMP: [5/0.26s] MySQL: [7/0.03s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m] entPhysicalDescr = No Such Object available on this agent at this OID SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[100,"ipmi_hostname"][0m 0.48ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",100,"ipmi"][0m 0.97ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",100,"ipmi"][0m 0.41ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",100,"ipmi"][0m 0.41ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",100,"ipmi"][0m 0.41ms] Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",100,"snmp"][0m 0.43ms] Current: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",100,"snmp"][0m 0.42ms] Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",100,"snmp"][0m 0.41ms] Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",100,"snmp"][0m 0.4ms] Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",100,"snmp"][0m 0.4ms] Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",100,"snmp"][0m 0.41ms] Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",100,"snmp"][0m 0.42ms] Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",100,"snmp"][0m 0.43ms] Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",100,"snmp"][0m 0.47ms] Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",100,"snmp"][0m 0.4ms] Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",100,"snmp"][0m 0.41ms] State: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",100,"snmp"][0m 0.4ms] Temperature: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",100,"snmp"][0m 0.41ms] Voltage: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",100,"snmp"][0m 0.42ms] Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",100,"snmp"][0m 0.42ms] Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",100,"snmp"][0m 0.43ms] Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",100,"snmp"][0m 0.4ms] Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",100,"snmp"][0m 0.4ms] Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",100,"snmp"][0m 0.41ms] Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",100,"snmp"][0m 0.4ms] Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",100,"snmp"][0m 0.41ms] Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",100,"snmp"][0m 0.42ms] Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",100,"snmp"][0m 0.4ms] >> Runtime for discovery module 'sensors': 0.0850 seconds with 16296 bytes >> SNMP: [1/0.07s] MySQL: [28/0.01s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m] fileSystemSpaceTable = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'hrStorageEntry'[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dskTable'[0m] dskTable = No Such Object available on this agent at this OID SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '100' AND `storage_type` != 'dsk' [0;33m[][0m 0.5ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '100' [0;33m[][0m 0.25ms] >> Runtime for discovery module 'storage': 0.1670 seconds with 8936 bytes >> SNMP: [3/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '100' [0;33m[][0m 0.57ms] >> Runtime for discovery module 'hr-device': 0.0970 seconds with 3656 bytes >> SNMP: [2/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'cdpCache'[0m] cdpCache = No Such Object available on this agent at this OID LLDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'lldpRemTable'[0m] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[100][0m 0.36ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[100][0m 0.69ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.49ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.4040 seconds with 5064 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipNetToPhysicalPhysAddress'[0m] ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 0:c:29:97:a8:29 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 0:50:56:99:51:3d ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 0:c:29:49:fd:66 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:e7:f4:27:84:26 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = a0:2b:b8:2c:b:19 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = b4:b6:86:f0:bf:50 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = ac:e2:d3:7:fe:84 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = d0:bf:9c:e0:7:44 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = dc:4a:3e:7:83:18 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = fc:3f:db:fe:45:bc ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 38:63:bb:b8:e9:ad ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 48:ba:4e:97:2c:95 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = fc:3f:db:f9:cc:6e ipNetToPhysicalPhysAddress[10][ipv4]["*"] = f0:6e:b:bd:fd:46 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 30:8d:99:14:5:c1 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = c8:d3:ff:72:df:7c ipNetToPhysicalPhysAddress[10][ipv4]["*"] = fc:3f:db:41:7d:5b ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 58:82:a8:95:da:14 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = f8:59:71:3d:9f:73 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:e7:f4:27:45:3e ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:5f:d3:35:c5:f1 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 28:e3:47:39:5b:9d ipNetToPhysicalPhysAddress[10][ipv4]["*"] = e4:e7:49:a1:ed:46 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:e7:f4:27:a4:6a ipNetToPhysicalPhysAddress[10][ipv4]["*"] = c4:9d:ed:e5:71:25 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:e7:f4:27:15:41 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 28:80:23:1:cc:65 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 98:e7:f4:be:aa:ef ipNetToPhysicalPhysAddress[10][ipv4]["*"] = dc:4a:3e:51:77:d1 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = d8:38:fc:2e:9:70 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 90:3a:72:1b:95:90 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = e8:1c:ba:13:79:e4 ipNetToPhysicalPhysAddress[10][ipv4]["*"] = 0:0:0:1:6:9 ipNetToPhysicalPhysAddress[11][ipv4]["*"] = 0:0:0:1:6:9 ipNetToPhysicalPhysAddress[13][ipv4]["*"] = 0:0:0:1:6:9 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'ipNetToMediaPhysAddress'[0m] ipNetToMediaPhysAddress[10][*] = 0:c:29:97:a8:29 ipNetToMediaPhysAddress[10][*] = 0:50:56:99:51:3d ipNetToMediaPhysAddress[10][*] = 0:c:29:49:fd:66 ipNetToMediaPhysAddress[10][*] = 98:e7:f4:27:84:26 ipNetToMediaPhysAddress[10][*] = a0:2b:b8:2c:b:19 ipNetToMediaPhysAddress[10][*] = b4:b6:86:f0:bf:50 ipNetToMediaPhysAddress[10][*] = ac:e2:d3:7:fe:84 ipNetToMediaPhysAddress[10][*] = d0:bf:9c:e0:7:44 ipNetToMediaPhysAddress[10][*] = dc:4a:3e:7:83:18 ipNetToMediaPhysAddress[10][*] = fc:3f:db:fe:45:bc ipNetToMediaPhysAddress[10][*] = 38:63:bb:b8:e9:ad ipNetToMediaPhysAddress[10][*] = 48:ba:4e:97:2c:95 ipNetToMediaPhysAddress[10][*] = fc:3f:db:f9:cc:6e ipNetToMediaPhysAddress[10][*] = f0:6e:b:bd:fd:46 ipNetToMediaPhysAddress[10][*] = 30:8d:99:14:5:c1 ipNetToMediaPhysAddress[10][*] = c8:d3:ff:72:df:7c ipNetToMediaPhysAddress[10][*] = fc:3f:db:41:7d:5b ipNetToMediaPhysAddress[10][*] = 58:82:a8:95:da:14 ipNetToMediaPhysAddress[10][*] = f8:59:71:3d:9f:73 ipNetToMediaPhysAddress[10][*] = 98:e7:f4:27:45:3e ipNetToMediaPhysAddress[10][*] = 98:5f:d3:35:c5:f1 ipNetToMediaPhysAddress[10][*] = 28:e3:47:39:5b:9d ipNetToMediaPhysAddress[10][*] = e4:e7:49:a1:ed:46 ipNetToMediaPhysAddress[10][*] = 98:e7:f4:27:a4:6a ipNetToMediaPhysAddress[10][*] = 98:e7:f4:27:15:41 ipNetToMediaPhysAddress[10][*] = 28:80:23:1:cc:65 ipNetToMediaPhysAddress[10][*] = 98:e7:f4:be:aa:ef ipNetToMediaPhysAddress[10][*] = dc:4a:3e:51:77:d1 ipNetToMediaPhysAddress[10][*] = d8:38:fc:2e:9:70 ipNetToMediaPhysAddress[10][*] = 90:3a:72:1b:95:90 ipNetToMediaPhysAddress[10][*] = e8:1c:ba:13:79:e4 ipNetToMediaPhysAddress[10][*] = 0:0:0:1:6:9 ipNetToMediaPhysAddress[11][*] = 0:0:0:1:6:9 ipNetToMediaPhysAddress[13][*] = 0:0:0:1:6:9 SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[100,""][0m 0.63ms] SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,10][0m 0.7ms] br0: 0:c:29:97:a8:29 => 10.62.33.2 0:50:56:99:51:3d => 10.62.33.11 0:c:29:49:fd:66 => 10.62.33.13 98:e7:f4:27:84:26 => 10.62.33.90 a0:2b:b8:2c:b:19 => 10.62.33.91 b4:b6:86:f0:bf:50 => 10.62.33.94 ac:e2:d3:7:fe:84 => 10.62.33.95 d0:bf:9c:e0:7:44 => 10.62.33.96 dc:4a:3e:7:83:18 => 10.62.33.103 fc:3f:db:fe:45:bc => 10.62.33.112 38:63:bb:b8:e9:ad => 10.62.33.113 48:ba:4e:97:2c:95 => 10.62.33.115 fc:3f:db:f9:cc:6e => 10.62.33.118 f0:6e:b:bd:fd:46 => 10.62.33.120 30:8d:99:14:5:c1 => 10.62.33.122 c8:d3:ff:72:df:7c => 10.62.33.129 fc:3f:db:41:7d:5b => 10.62.33.130 58:82:a8:95:da:14 => 10.62.33.131 f8:59:71:3d:9f:73 => 10.62.33.132 98:e7:f4:27:45:3e => 10.62.33.136 98:5f:d3:35:c5:f1 => 10.62.33.143 28:e3:47:39:5b:9d => 10.62.33.146 e4:e7:49:a1:ed:46 => 10.62.33.148 98:e7:f4:27:a4:6a => 10.62.33.149 98:e7:f4:27:15:41 => 10.62.33.152 28:80:23:1:cc:65 => 10.62.33.170 98:e7:f4:be:aa:ef => 10.62.33.172 dc:4a:3e:51:77:d1 => 10.62.33.186 d8:38:fc:2e:9:70 => 10.62.33.243 90:3a:72:1b:95:90 => 10.62.33.244 e8:1c:ba:13:79:e4 => 10.62.33.252 0:0:0:1:6:9 => 169.254.17.1 c4:9d:ed:e5:71:25 => 10.62.33.150 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,11][0m 0.38ms] br1: 0:0:0:1:6:9 => 169.254.17.1 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[100,13][0m 0.37ms] br6: 0:0:0:1:6:9 => 169.254.17.1 SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 0.89ms] >> Runtime for discovery module 'arp-table': 0.1600 seconds with 41016 bytes >> SNMP: [0/0.00s] MySQL: [5/0.00s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m'/usr/bin/snmpgetnext' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqvn' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m] "lo" No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[100,""][0m 0.62ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[100,""][0m 0.42ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[100][0m 0.33ms] >> Runtime for discovery module 'bgp-peers': 0.0740 seconds with 5568 bytes >> SNMP: [1/0.07s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[100][0m 0.32ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.1580 seconds with 9200 bytes >> SNMP: [2/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'diskIOEntry'[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '100' [0;33m[][0m 0.49ms] >> Runtime for discovery module 'ucd-diskio': 0.0540 seconds with 3112 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[100][0m 0.74ms] SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dot1dStpProtocolSpecification.0'[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0500 seconds with 5744 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### ap-count: SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OUQnt' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.25053.1.2.1.1.1.15.1.0'[0m] .*.4.1.25*.*.0 = No Such Object available on this agent at this OID Discovered LibreNMS\Device\WirelessSensor Array ( [sensor_class] => ap-count [device_id] => 100 [sensor_oids] => Array ( [0] => .1.3.6.1.4.1.25053.1.2.1.1.1.15.1.0 ) [sensor_index] => 1 [sensor_type] => ruckuswireless [sensor_descr] => Connected APs [sensor_divisor] => 1 [sensor_multiplier] => 1 [sensor_aggregator] => sum [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_current] => [entPhysicalIndex] => [entPhysicalIndex_measured] => [access_point_id] => ) SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"ap-count"][0m 1.02ms] clients: SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OUQnt' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.25053.1.2.1.1.1.15.2.0'[0m] .*.4.1.25*.*.0 = No Such Object available on this agent at this OID Discovered LibreNMS\Device\WirelessSensor Array ( [sensor_class] => clients [device_id] => 100 [sensor_oids] => Array ( [0] => .1.3.6.1.4.1.25053.1.2.1.1.1.15.2.0 ) [sensor_index] => 1 [sensor_type] => ruckuswireless [sensor_descr] => Clients: Total [sensor_divisor] => 1 [sensor_multiplier] => 1 [sensor_aggregator] => sum [sensor_limit] => [sensor_limit_warn] => [sensor_limit_low] => [sensor_limit_low_warn] => [sensor_current] => [entPhysicalIndex] => [entPhysicalIndex_measured] => [access_point_id] => ) SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"clients"][0m 0.63ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"quality"][0m 0.31ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"capacity"][0m 0.31ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"utilization"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"rate"][0m 0.5ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"ccq"][0m 0.48ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"snr"][0m 0.49ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"ssr"][0m 0.54ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"mse"][0m 0.48ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"xpi"][0m 0.42ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"rssi"][0m 0.33ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"power"][0m 0.32ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"noise-floor"][0m 0.33ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"errors"][0m 0.32ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"error-ratio"][0m 0.35ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"error-rate"][0m 0.33ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"frequency"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[100,"distance"][0m 0.29ms] >> Runtime for discovery module 'wireless': 0.1030 seconds with 140664 bytes >> SNMP: [2/0.09s] MySQL: [19/0.01s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[100][0m 0.14ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[100][0m 0.13ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' '' '-a' 'SHA' '-A' 'PASSWORD '-u' 'USER '-x' 'AES' '-X' 'PASSWORD '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ruckus' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.1030 seconds with 536 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[100,"poll_mib"][0m 0.33ms] SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[4.823,100][0m 1.52ms] Discovered in 4.823 seconds SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"phy-ruckus","start":1547344347.712239,"duration":"4.952","devices":1,"poller":"PHY-V202"}[0m 8.18ms] ./discovery.php phy-ruckus 2019-01-13 02:52:32 - 1 devices discovered in 4.952 secs SNMP [42/2.62s]: Get[20/1.03s] Getnext[1/0.07s] Walk[21/1.51s] MySQL [130/0.42s]: Cell[52/0.02s] Row[-44/-0.02s] Rows[65/0.04s] Column[2/0.00s] Update[48/0.36s] Insert[2/0.01s] Delete[5/0.00s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]