LibreNMS Discovery SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 0.44ms] SQL[[1;33mselect count(*) as aggregate from `migrations` limit 1 [0;33m[][0m 0.32ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.25ms] =================================== Version info: Commit SHA: e782bdbe02a21858a5df6e0a1ee4da5c8da6c71f Commit Date: 1621297073 DB Schema: 2021_04_08_151101_add_foreign_keys_to_port_group_port_table (208) PHP: 7.4.12 MySQL: 10.5.9-MariaDB RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! Updating os_def.cache SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '[REMOVED]' ORDER BY device_id DESC [0;33m[][0m 0.96ms] SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[240][0m 0.5ms] SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[240][0m 0.38ms] [REMOVED] 240 vertiv-pdu SQL[[1;33mselect `hostname`, `overwrite_ip` from `devices` where `hostname` = ? limit 1 [0;33m["[REMOVED]"][0m 0.35ms] [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '[REMOVED]' response: {"xmt":3,"rcv":3,"loss":0,"min":0.54000000000000004,"max":0.57999999999999996,"avg":0.55000000000000004,"dup":0,"exitcode":0} SQL[[1;33mselect `device_groups`.*, `device_group_device`.`device_id` as `pivot_device_id`, `device_group_device`.`device_group_id` as `pivot_device_group_id` from `device_groups` inner join `device_group_device` on `device_groups`.`id` = `device_group_device`.`device_group_id` where `device_group_device`.`device_id` = ? [0;33m[240][0m 0.72ms] SQL[[1;33mselect * from `locations` where `locations`.`id` = ? limit 1 [0;33m[132][0m 0.35ms] SQL[[1;33mselect exists(select * from `alert_schedule` where (`start` <= ? and `end` >= ? and (`recurring` = ? or (`recurring` = ? and ((time(`start`) < time xss=removed> ?) or (time(`start`) > time(`end`) and (time(`end`) <= ? or time(`start`) > ?))) and (`recurring_day` like ? or `recurring_day` is null)))) and (exists (select * from `devices` inner join `alert_schedulables` on `devices`.`device_id` = `alert_schedulables`.`alert_schedulable_id` where `alert_schedule`.`schedule_id` = `alert_schedulables`.`schedule_id` and `alert_schedulables`.`alert_schedulable_type` = ? and `alert_schedulables`.`alert_schedulable_id` = ?) or exists (select * from `locations` inner join `alert_schedulables` on `locations`.`id` = `alert_schedulables`.`alert_schedulable_id` where `alert_schedule`.`schedule_id` = `alert_schedulables`.`schedule_id` and `alert_schedulables`.`alert_schedulable_type` = ? and `alert_schedulables`.`alert_schedulable_id` = ?))) as `exists` [0;33m["2021-05-19T12:28:49.340174Z","2021-05-19T12:28:49.340174Z",0,1,"12:28:49","12:28:49","12:28:49","12:28:49","[43m%","device",240,"location",132][0m 0.84ms] SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`,`debug`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW(),:debug) [0;33m{"xmt":3,"rcv":3,"loss":0,"min":0.54000000000000004,"max":0.57999999999999996,"avg":0.55000000000000004,"device_id":240,"debug":"[]"}[0m 0.9ms] SQL[[1;33mUPDATE `devices` set `last_ping`=?,`last_ping_timetaken`=? WHERE device_id=? [0;33m["2021-05-19 08:28:49",0.55000000000000004,240][0m 0.77ms] SNMP Check response code: 0 Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OUQn' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'sysName.0' 'sysObjectID.0' 'sysDescr.0'[0m] .*.*.0 = [REMOVED] .*.*.0 = .*.4.1.21* .*.*.0 = [REMOVED] | [REMOVED] | .1.3.6.1.4.1.21239.42.1.53 | Attempting to initialize OS: vertiv-pdu Attempting to initialize OS: vertiv OS initialized as Generic OS: Vertiv PDU (vertiv-pdu) >> Runtime for discovery module 'core': 0.0570 seconds with 215416 bytes >> SNMP: [2/0.12s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS Device #### Load disco module os #### Yaml location data: SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Oqv' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.0'[0m] [REMOVED] SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'sysContact.0'[0m] cloudservices@idealintegrations.net SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'VERTIV-V5-MIB::productModelNumber.0' 'VERTIV-V5-MIB::productSerialNumber.0' 'VERTIV-V5-MIB::productVersion.0'[0m] VERTIV-V5-MIB::productModelNumber.0 = MN03EDR1-15P3B8-6PS15D0H10-S VERTIV-V5-MIB::productSerialNumber.0 = [REMOVED] VERTIV-V5-MIB::productVersion.0 = 5.6.1 Yaml OS data: {"VERTIV-V5-MIB::productModelNumber.0":"MN03EDR1-15P3B8-6PS15D0H10-S","VERTIV-V5-MIB::productSerialNumber.0":"[REMOVED]","VERTIV-V5-MIB::productVersion.0":"5.6.1"} Location: [REMOVED] Hardware: MN03EDR1-15P3B8-6PS15D0H10-S OS Version: 5.6.1 OS Features: Serial: [REMOVED] >> Runtime for discovery module 'os': 0.1830 seconds with 624312 bytes >> SNMP: [4/0.17s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS Device #### Load disco module ports #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifDescr'[0m] ifDescr.1 = lo ifDescr.2 = eth0 ifDescr.3 = port1 ifDescr.4 = port2 ifDescr.12 = br0 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifName'[0m] ifName = No Such Object available on this agent at this OID Invalid snmp_walk() data = ifName = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifAlias'[0m] ifAlias = No Such Object available on this agent at this OID Invalid snmp_walk() data = ifAlias = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifType'[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd ifType.3 = ethernetCsmacd ifType.4 = ethernetCsmacd ifType.12 = ethernetCsmacd SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifOperStatus'[0m] ifOperStatus.1 = up ifOperStatus.2 = up ifOperStatus.3 = up ifOperStatus.4 = down ifOperStatus.12 = up array ( 1 => array ( 'ifDescr' => 'lo', 'ifType' => 'softwareLoopback', 'ifOperStatus' => 'up', ), 2 => array ( 'ifDescr' => 'eth0', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 3 => array ( 'ifDescr' => 'port1', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), 4 => array ( 'ifDescr' => 'port2', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'down', ), 12 => array ( 'ifDescr' => 'br0', 'ifType' => 'ethernetCsmacd', 'ifOperStatus' => 'up', ), ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[240][0m 0.99ms] Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["lo","softwareLoopback","up",1,"lo","lo",12274][0m 0.32ms] . Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["eth0","ethernetCsmacd","up",2,"eth0","eth0",12275][0m 0.3ms] . Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["port1","ethernetCsmacd","up",3,"port1","port1",12276][0m 0.29ms] . Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["port2","ethernetCsmacd","down",4,"port2","port2",12277][0m 0.29ms] . Using ifDescr as ifAlias Using ifDescr as ifName SQL[[1;33mUPDATE `ports` set `ifDescr`=?,`ifType`=?,`ifOperStatus`=?,`ifIndex`=?,`ifAlias`=?,`ifName`=? WHERE `port_id` = ? [0;33m["br0","ethernetCsmacd","up",12,"br0","br0",12278][0m 0.28ms] . >> Runtime for discovery module 'ports': 0.2780 seconds with 8848 bytes >> SNMP: [5/0.27s] MySQL: [6/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '240' [0;33m[][0m 0.34ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ifStackStatus'[0m] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 0.0750 seconds with 3192 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'entPhysicalEntry'[0m] entPhysicalEntry = No Such Object available on this agent at this OID MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 1 in (none) Invalid snmp_walk() data = entPhysicalEntry = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[240][0m 0.6ms] >> Runtime for discovery module 'entity-physical': 0.0790 seconds with 6832 bytes >> SNMP: [1/0.08s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS Device Module [ entity-state ] disabled globally. Modules status: Global+ OS Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'hrProcessorLoad'[0m] hrProcessorLoad = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrProcessorLoad = No Such Object available on this agent at this OID UCD Resources: SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[240][0m 0.53ms] SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Ovq' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.0'[0m] No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[240][0m 0.61ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.82ms] >> Runtime for discovery module 'processors': 0.1220 seconds with 103992 bytes >> SNMP: [2/0.12s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS Device #### Load disco module mempools #### communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'hrStorageTable'[0m] hrStorageTable = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'hrMemorySize.0'[0m] No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.0'[0m] memTotalSwap.0 = No Such Object available on this agent at this OID memAvailSwap.0 = No Such Object available on this agent at this OID memTotalReal.0 = No Such Object available on this agent at this OID memAvailReal.0 = No Such Object available on this agent at this OID memBuffer.0 = No Such Object available on this agent at this OID memCached.0 = No Such Object available on this agent at this OID memSysAvail.0 = No Such Object available on this agent at this OID SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[240][0m 0.61ms] >> Runtime for discovery module 'mempools': 0.1620 seconds with 155672 bytes >> SNMP: [2/0.11s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[240][0m 0.34ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2648 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS Device Module [ cisco-mac-accounting ] disabled globally. Modules status: Global- OS Device Module [ cisco-pw ] disabled globally. Modules status: Global- OS Device Module [ vrf ] disabled globally. Modules status: Global- OS Device Module [ cisco-cef ] disabled globally. Modules status: Global- OS Device Module [ cisco-sla ] disabled globally. Modules status: Global- OS Device Module [ cisco-cbqos ] disabled globally. Modules status: Global- OS Device Module [ cisco-otv ] disabled globally. Modules status: Global- OS Device Module [ cisco-qfp ] disabled globally. Modules status: Global+ OS Device #### Load disco module ipv4-addresses #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipAdEntIfIndex'[0m] ipAdEntIfIndex No Such Object available on this agent at this OID Invalid snmp_walk() data = ipAdEntIfIndex No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Oqv' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipAdEntNetMask.'[0m] No Such Object available on this agent at this OID SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[240][0m 2.39ms] >> Runtime for discovery module 'ipv4-addresses': 0.1100 seconds with 40928 bytes >> SNMP: [2/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS Device #### Load disco module ipv6-addresses #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Osq' '-Ln' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipAddressIfIndex.ipv6'[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID Invalid snmp_walk() data = ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipv6AddrPfxLength'[0m] .*.*.8.1.2 No Such Object available on this agent at this OID Invalid snmp_walk() data = .1.3.6.1.2.1.55.1.8.1.2 No Such Object available on this agent at this OID SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[240][0m 0.8ms] >> Runtime for discovery module 'ipv6-addresses': 0.1120 seconds with 3560 bytes >> SNMP: [2/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS Device Module [ route ] disabled globally. Modules status: Global+ OS Device #### Load disco module sensors #### Caching data: os sensors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OteQUs' '-Ih' '-m' 'VERTIV-V5-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'pduLineTable'[0m] pduLineName.1 = "Line A" pduLineName.2 = "Line B" pduLineName.3 = "Line C" pduLineLabel.1 = "Line A" pduLineLabel.2 = "Line B" pduLineLabel.3 = "Line C" pduLineCurrent.1 = 1264 pduLineCurrent.2 = 1272 pduLineCurrent.3 = 1269 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OteQUs' '-Ih' '-m' 'VERTIV-V5-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'pduBreakerTable'[0m] pduBreakerName.1 = "Circuit 1" pduBreakerName.2 = "Circuit 2" pduBreakerName.3 = "Circuit 3" pduBreakerName.4 = "Circuit 4" pduBreakerName.5 = "Circuit 5" pduBreakerName.6 = "Circuit 6" pduBreakerLabel.1 = "Circuit 1 - Phase AB" pduBreakerLabel.2 = "Circuit 2 - Phase BC" pduBreakerLabel.3 = "Circuit 3 - Phase CA" pduBreakerLabel.4 = "Circuit 4 - Phase AB" pduBreakerLabel.5 = "Circuit 5 - Phase BC" pduBreakerLabel.6 = "Circuit 6 - Phase CA" pduBreakerCurrent.1 = 476 pduBreakerCurrent.2 = 480 pduBreakerCurrent.3 = 475 pduBreakerCurrent.4 = 256 pduBreakerCurrent.5 = 254 pduBreakerCurrent.6 = 254 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OteQUs' '-Ih' '-m' 'VERTIV-V5-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'pduPhaseTable'[0m] pduPhaseName.1 = "Phase AB" pduPhaseName.2 = "Phase BC" pduPhaseName.3 = "Phase CA" pduPhaseLabel.1 = "Phase AB" pduPhaseLabel.2 = "Phase BC" pduPhaseLabel.3 = "Phase CA" pduPhaseVoltage.1 = 2068 pduPhaseVoltage.2 = 2078 pduPhaseVoltage.3 = 2063 pduPhaseCurrent.1 = 734 pduPhaseCurrent.2 = 734 pduPhaseCurrent.3 = 730 pduPhaseRealPower.1 = 1482 pduPhaseRealPower.2 = 1489 pduPhaseRealPower.3 = 1471 pduPhaseApparentPower.1 = 1518 pduPhaseApparentPower.2 = 1524 pduPhaseApparentPower.3 = 1505 pduPhasePowerFactor.1 = 97 pduPhasePowerFactor.2 = 97 pduPhasePowerFactor.3 = 97 pduPhaseEnergy.1 = 4958739 pduPhaseEnergy.2 = 5034896 pduPhaseEnergy.3 = 4943895 pduPhaseBalance.1 = 33 pduPhaseBalance.2 = 33 pduPhaseBalance.3 = 33 pduPhaseCurrentCrestFactor.1 = 154 pduPhaseCurrentCrestFactor.2 = 156 pduPhaseCurrentCrestFactor.3 = 153 ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'entPhysicalDescr'[0m] entPhysicalDescr = No Such Object available on this agent at this OID Invalid snmp_walk() data = entPhysicalDescr = No Such Object available on this agent at this OID SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",240,"ipmi"][0m 0.99ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",240,"ipmi"][0m 0.68ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",240,"ipmi"][0m 0.6ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",240,"ipmi"][0m 0.6ms] Airflow: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",240,"snmp"][0m 0.65ms] Current: Dynamic Discovery (current): array ( 'data' => array ( 0 => array ( 'oid' => 'pduLineTable', 'value' => 'pduLineCurrent', 'num_oid' => '.1.3.6.1.4.1.21239.5.2.3.4.1.4.{{ $index }}', 'descr' => 'pduLineName', 'divisor' => 100, ), 1 => array ( 'oid' => 'pduBreakerTable', 'value' => 'pduBreakerCurrent', 'num_oid' => '.1.3.6.1.4.1.21239.5.2.3.3.1.4.{{ $index }}', 'descr' => 'pduBreakerLabel', 'divisor' => 100, ), 2 => array ( 'oid' => 'pduPhaseTable', 'value' => 'pduPhaseCurrent', 'num_oid' => '.1.3.6.1.4.1.21239.5.2.3.2.1.8.{{ $index }}', 'descr' => 'pduPhaseName', 'divisor' => 100, ), ), ) Data pduLineTable: array ( 1 => array ( 'pduLineName' => 'Line A', 'pduLineLabel' => 'Line A', 'pduLineCurrent' => '1264', ), 2 => array ( 'pduLineName' => 'Line B', 'pduLineLabel' => 'Line B', 'pduLineCurrent' => '1272', ), 3 => array ( 'pduLineName' => 'Line C', 'pduLineLabel' => 'Line C', 'pduLineCurrent' => '1269', ), ) Sensor fetched value: 1264 Cur 12.64, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.4.1.4.1, 1, vertiv-pdu, Line A, snmp, 100, 1, , 12.64, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","1"][0m 0.59ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","1"][0m 0.54ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.4.1.4.1","Line A",1,100,null,null,null,null,11302][0m 1.06ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11302,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 1 Line A",""][0m 0.84ms] ( 1 updated ) Sensor fetched value: 1272 Cur 12.72, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.4.1.4.2, 2, vertiv-pdu, Line B, snmp, 100, 1, , 12.72, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","2"][0m 0.54ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","2"][0m 0.53ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.4.1.4.2","Line B",1,100,null,null,null,null,11303][0m 0.64ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11303,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 2 Line B",""][0m 0.65ms] ( 1 updated ) Sensor fetched value: 1269 Cur 12.69, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.4.1.4.3, 3, vertiv-pdu, Line C, snmp, 100, 1, , 12.69, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","3"][0m 0.48ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","3"][0m 0.54ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.4.1.4.3","Line C",1,100,null,null,null,null,11304][0m 0.65ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11304,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 3 Line C",""][0m 0.56ms] ( 1 updated ) Data pduBreakerTable: array ( 1 => array ( 'pduBreakerName' => 'Circuit 1', 'pduBreakerLabel' => 'Circuit 1 - Phase AB', 'pduBreakerCurrent' => '476', ), 2 => array ( 'pduBreakerName' => 'Circuit 2', 'pduBreakerLabel' => 'Circuit 2 - Phase BC', 'pduBreakerCurrent' => '480', ), 3 => array ( 'pduBreakerName' => 'Circuit 3', 'pduBreakerLabel' => 'Circuit 3 - Phase CA', 'pduBreakerCurrent' => '475', ), 4 => array ( 'pduBreakerName' => 'Circuit 4', 'pduBreakerLabel' => 'Circuit 4 - Phase AB', 'pduBreakerCurrent' => '256', ), 5 => array ( 'pduBreakerName' => 'Circuit 5', 'pduBreakerLabel' => 'Circuit 5 - Phase BC', 'pduBreakerCurrent' => '254', ), 6 => array ( 'pduBreakerName' => 'Circuit 6', 'pduBreakerLabel' => 'Circuit 6 - Phase CA', 'pduBreakerCurrent' => '254', ), ) Sensor fetched value: 476 Cur 4.76, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.1, 1, vertiv-pdu, Circuit 1 - Phase AB, snmp, 100, 1, , 4.76, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","1"][0m 0.48ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","1"][0m 0.54ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.3.1.4.1","Circuit 1 - Phase AB",1,100,null,null,null,null,11302][0m 0.7ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11302,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 1 Circuit 1 - Phase AB",""][0m 0.62ms] ( 1 updated ) Sensor fetched value: 480 Cur 4.8, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.2, 2, vertiv-pdu, Circuit 2 - Phase BC, snmp, 100, 1, , 4.8, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","2"][0m 0.47ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","2"][0m 0.51ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.3.1.4.2","Circuit 2 - Phase BC",1,100,null,null,null,null,11303][0m 0.64ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11303,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 2 Circuit 2 - Phase BC",""][0m 0.61ms] ( 1 updated ) Sensor fetched value: 475 Cur 4.75, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.3, 3, vertiv-pdu, Circuit 3 - Phase CA, snmp, 100, 1, , 4.75, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","3"][0m 0.54ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","3"][0m 0.52ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.3.1.4.3","Circuit 3 - Phase CA",1,100,null,null,null,null,11304][0m 0.69ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11304,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 3 Circuit 3 - Phase CA",""][0m 0.59ms] ( 1 updated ) Sensor fetched value: 256 Cur 2.56, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.4, 4, vertiv-pdu, Circuit 4 - Phase AB, snmp, 100, 1, , 2.56, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","4"][0m 0.46ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","4"][0m 0.5ms] .Sensor fetched value: 254 Cur 2.54, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.5, 5, vertiv-pdu, Circuit 5 - Phase BC, snmp, 100, 1, , 2.54, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","5"][0m 0.44ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","5"][0m 0.51ms] .Sensor fetched value: 254 Cur 2.54, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.3.1.4.6, 6, vertiv-pdu, Circuit 6 - Phase CA, snmp, 100, 1, , 2.54, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","6"][0m 0.44ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","6"][0m 0.5ms] .Data pduPhaseTable: array ( 1 => array ( 'pduPhaseName' => 'Phase AB', 'pduPhaseLabel' => 'Phase AB', 'pduPhaseVoltage' => '2068', 'pduPhaseCurrent' => '734', 'pduPhaseRealPower' => '1482', 'pduPhaseApparentPower' => '1518', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '4958739', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '154', ), 2 => array ( 'pduPhaseName' => 'Phase BC', 'pduPhaseLabel' => 'Phase BC', 'pduPhaseVoltage' => '2078', 'pduPhaseCurrent' => '734', 'pduPhaseRealPower' => '1489', 'pduPhaseApparentPower' => '1524', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '5034896', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '156', ), 3 => array ( 'pduPhaseName' => 'Phase CA', 'pduPhaseLabel' => 'Phase CA', 'pduPhaseVoltage' => '2063', 'pduPhaseCurrent' => '730', 'pduPhaseRealPower' => '1471', 'pduPhaseApparentPower' => '1505', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '4943895', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '153', ), ) Sensor fetched value: 734 Cur 7.34, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.8.1, 1, vertiv-pdu, Phase AB, snmp, 100, 1, , 7.34, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","1"][0m 0.46ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","1"][0m 0.58ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.2.1.8.1","Phase AB",1,100,null,null,null,null,11302][0m 0.63ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11302,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 1 Phase AB",""][0m 1.44ms] ( 1 updated ) Sensor fetched value: 734 Cur 7.34, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.8.2, 2, vertiv-pdu, Phase BC, snmp, 100, 1, , 7.34, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","2"][0m 0.63ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","2"][0m 0.72ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.2.1.8.2","Phase BC",1,100,null,null,null,null,11303][0m 0.72ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11303,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 2 Phase BC",""][0m 0.71ms] ( 1 updated ) Sensor fetched value: 730 Cur 7.3, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.8.3, 3, vertiv-pdu, Phase CA, snmp, 100, 1, , 7.3, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","current",240,"vertiv-pdu","3"][0m 0.61ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["current",240,"vertiv-pdu","3"][0m 0.7ms] SQL[[1;33mUPDATE `sensors` set `sensor_oid`=?,`sensor_descr`=?,`sensor_multiplier`=?,`sensor_divisor`=?,`entPhysicalIndex`=?,`entPhysicalIndex_measured`=?,`user_func`=?,`group`=? WHERE `sensor_id` = ? [0;33m[".1.3.6.1.4.1.21239.5.2.3.2.1.8.3","Phase CA",1,100,null,null,null,null,11304][0m 0.77ms] USQL[[1;33minsert into `eventlog` (`device_id`, `reference`, `type`, `datetime`, `severity`, `message`, `username`) values (?, ?, ?, ?, ?, ?, ?) [0;33m[240,11304,"sensor","2021-05-19 08:28:50",3,"Sensor Updated: current vertiv-pdu 3 Phase CA",""][0m 0.67ms] ( 1 updated ) array ( 'vertiv-pdu' => array ( 1 => 1, 2 => 1, 3 => 1, 4 => 1, 5 => 1, 6 => 1, ), ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",240,"snmp"][0m 1.14ms] 1 -> vertiv-pdu 2 -> vertiv-pdu 3 -> vertiv-pdu 4 -> vertiv-pdu 5 -> vertiv-pdu 6 -> vertiv-pdu Charge: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",240,"snmp"][0m 0.75ms] Dbm: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",240,"snmp"][0m 0.66ms] Fanspeed: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",240,"snmp"][0m 0.59ms] Frequency: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",240,"snmp"][0m 0.57ms] Humidity: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",240,"snmp"][0m 0.56ms] Load: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",240,"snmp"][0m 0.61ms] Loss: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",240,"snmp"][0m 0.57ms] Power: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",240,"snmp"][0m 0.58ms] Power_consumed: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",240,"snmp"][0m 0.56ms] Power_factor: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",240,"snmp"][0m 0.57ms] Runtime: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",240,"snmp"][0m 0.57ms] Signal: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",240,"snmp"][0m 0.57ms] State: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",240,"snmp"][0m 0.57ms] Count: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",240,"snmp"][0m 0.57ms] Temperature: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",240,"snmp"][0m 0.57ms] Tv_signal: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",240,"snmp"][0m 0.57ms] Voltage: Dynamic Discovery (voltage): array ( 'data' => array ( 0 => array ( 'oid' => 'pduPhaseTable', 'value' => 'pduPhaseVoltage', 'num_oid' => '.1.3.6.1.4.1.21239.5.2.3.2.1.4.{{ $index }}', 'descr' => 'pduPhaseName', 'divisor' => 100, ), ), ) Data pduPhaseTable: array ( 1 => array ( 'pduPhaseName' => 'Phase AB', 'pduPhaseLabel' => 'Phase AB', 'pduPhaseVoltage' => '2068', 'pduPhaseCurrent' => '734', 'pduPhaseRealPower' => '1482', 'pduPhaseApparentPower' => '1518', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '4958739', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '154', ), 2 => array ( 'pduPhaseName' => 'Phase BC', 'pduPhaseLabel' => 'Phase BC', 'pduPhaseVoltage' => '2078', 'pduPhaseCurrent' => '734', 'pduPhaseRealPower' => '1489', 'pduPhaseApparentPower' => '1524', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '5034896', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '156', ), 3 => array ( 'pduPhaseName' => 'Phase CA', 'pduPhaseLabel' => 'Phase CA', 'pduPhaseVoltage' => '2063', 'pduPhaseCurrent' => '730', 'pduPhaseRealPower' => '1471', 'pduPhaseApparentPower' => '1505', 'pduPhasePowerFactor' => '97', 'pduPhaseEnergy' => '4943895', 'pduPhaseBalance' => '33', 'pduPhaseCurrentCrestFactor' => '153', ), ) Sensor fetched value: 2068 Cur 20.68, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.4.1, 1, vertiv-pdu, Phase AB, snmp, 100, 1, , 20.68, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",240,"vertiv-pdu","1"][0m 0.48ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",240,"vertiv-pdu","1"][0m 0.5ms] .Sensor fetched value: 2078 Cur 20.78, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.4.2, 2, vertiv-pdu, Phase BC, snmp, 100, 1, , 20.78, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",240,"vertiv-pdu","2"][0m 0.44ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",240,"vertiv-pdu","2"][0m 0.51ms] .Sensor fetched value: 2063 Cur 20.63, Low: null, Low Warn: null, Warn: null, High: null Discover sensor: .1.3.6.1.4.1.21239.5.2.3.2.1.4.3, 3, vertiv-pdu, Phase CA, snmp, 100, 1, , 20.63, (limits: LL: , LW: , W: , H: ) SQL[[1;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= ? AND `sensor_class` = ? AND `device_id` = ? AND sensor_type = ? AND `sensor_index` = ? [0;33m["snmp","voltage",240,"vertiv-pdu","3"][0m 0.47ms] SQL[[1;33mSELECT * FROM `sensors` WHERE `sensor_class` = ? AND `device_id` = ? AND `sensor_type` = ? AND `sensor_index` = ? [0;33m["voltage",240,"vertiv-pdu","3"][0m 0.49ms] .array ( 'vertiv-pdu' => array ( 1 => 1, 2 => 1, 3 => 1, ), ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",240,"snmp"][0m 0.65ms] 1 -> vertiv-pdu 2 -> vertiv-pdu 3 -> vertiv-pdu Snr: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",240,"snmp"][0m 0.58ms] Pressure: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",240,"snmp"][0m 0.57ms] Cooling: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",240,"snmp"][0m 0.56ms] Delay: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",240,"snmp"][0m 0.55ms] Quality_factor: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",240,"snmp"][0m 0.56ms] Chromatic_dispersion: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",240,"snmp"][0m 0.56ms] Ber: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",240,"snmp"][0m 0.55ms] Eer: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",240,"snmp"][0m 0.55ms] Waterflow: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",240,"snmp"][0m 0.57ms] Percent: array ( ) SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",240,"snmp"][0m 0.56ms] >> Runtime for discovery module 'sensors': 0.4170 seconds with 360560 bytes >> SNMP: [4/0.34s] MySQL: [57/0.04s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS Device #### Load disco module storage #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'aixFsTableEntry'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (IBM-AIX-MIB): At line 1 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (IBM-AIX-MIB): At line 1 in (none) aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) -> aixFsTableEntry) aix_filesystem : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161' 'fileSystemSpaceTable'[0m] fileSystemSpaceTable = No Such Object available on this agent at this OID Invalid snmp_walk() data = fileSystemSpaceTable = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'datasetTable'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (FREENAS-MIB): At line 1 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (FREENAS-MIB): At line 1 in (none) datasetTable: Unknown Object Identifier (Sub-id not found: (top) -> datasetTable) SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '240' AND `storage_type` != 'dataset' [0;33m[][0m 0.54ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'zpoolTable'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (FREENAS-MIB): At line 1 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (FREENAS-MIB): At line 1 in (none) zpoolTable: Unknown Object Identifier (Sub-id not found: (top) -> zpoolTable) SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '240' AND `storage_type` != 'zpool' [0;33m[][0m 0.74ms] hrStorage : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dskTable'[0m] dskTable = No Such Object available on this agent at this OID Invalid snmp_walk() data = dskTable = No Such Object available on this agent at this OID SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '240' AND `storage_type` != 'dsk' [0;33m[][0m 0.5ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '240' [0;33m[][0m 0.33ms] >> Runtime for discovery module 'storage': 0.2480 seconds with 21328 bytes >> SNMP: [5/0.24s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS Device #### Load disco module hr-device #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'hrDeviceEntry'[0m] hrDeviceEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'hrProcessorEntry'[0m] hrProcessorEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = hrProcessorEntry = No Such Object available on this agent at this OID array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '240' [0;33m[][0m 0.65ms] >> Runtime for discovery module 'hr-device': 0.1040 seconds with 3704 bytes >> SNMP: [2/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'cdpCache'[0m] Exitcode: 1 MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (CISCO-CDP-MIB): At line 1 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) MIB search path: /opt/librenms/mibs:/opt/librenms/mibs/vertiv Cannot find module (CISCO-CDP-MIB): At line 1 in (none) cdpCache: Unknown Object Identifier (Sub-id not found: (top) -> cdpCache) LLDP-MIB: communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'lldpRemTable'[0m] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[240][0m 0.63ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[240][0m 0.77ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.16ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.1030 seconds with 6328 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS Device #### Load disco module arp-table #### communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipNetToPhysicalPhysAddress'[0m] ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'ipNetToMediaPhysAddress'[0m] ipNetToMediaPhysAddress = No Such Object available on this agent at this OID SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[240,""][0m 2.14ms] SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 7.7ms] >> Runtime for discovery module 'arp-table': 0.1220 seconds with 2464 bytes >> SNMP: [0/0.00s] MySQL: [2/0.01s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS Device Module [ discovery-arp ] disabled globally. Modules status: Global- OS Device Module [ junose-atm-vp ] disabled globally. Modules status: Global+ OS Device #### Load disco module bgp-peers #### SNMP[[0;36m'/usr/bin/snmpgetnext' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsv' '-m' 'BGP4-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'bgpLocalAs'[0m] 0:0:00:00.00 No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[240,""][0m 0.49ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[240,""][0m 0.28ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[240][0m 0.46ms] >> Runtime for discovery module 'bgp-peers': 0.0560 seconds with 6128 bytes >> SNMP: [1/0.05s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[240][0m 0.36ms] SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dot1dBasePortIfIndex'[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.0'[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.1130 seconds with 9768 bytes >> SNMP: [2/0.11s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS Device Module [ vmware-vminfo ] disabled globally. Modules status: Global- OS Device Module [ libvirt-vminfo ] disabled globally. Modules status: Global- OS Device Module [ printer-supplies ] disabled globally. Modules status: Global+ OS Device #### Load disco module ucd-diskio #### SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'diskIOEntry'[0m] diskIOEntry = No Such Object available on this agent at this OID Invalid snmp_walk() data = diskIOEntry = No Such Object available on this agent at this OID array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '240' [0;33m[][0m 0.52ms] >> Runtime for discovery module 'ucd-diskio': 0.0500 seconds with 3224 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS Device Module [ applications ] disabled globally. Modules status: Global+ OS Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 768 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[240][0m 0.4ms] SNMP[[0;36m'/usr/bin/snmpget' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-Oqv' '-m' 'RSTP-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dot1dStpProtocolSpecification.0'[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0510 seconds with 5888 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 280 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS Device Module [ loadbalancers ] disabled globally. Modules status: Global- OS Device Module [ mef ] disabled globally. Modules status: Global+ OS Device #### Load disco module wireless #### SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"ap-count"][0m 0.64ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"clients"][0m 0.38ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"quality"][0m 0.37ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"capacity"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"utilization"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"rate"][0m 0.35ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"ccq"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"snr"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"sinr"][0m 0.37ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"rsrp"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"rsrq"][0m 0.35ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"ssr"][0m 0.36ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"mse"][0m 0.37ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"xpi"][0m 0.44ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"rssi"][0m 0.4ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"power"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"noise-floor"][0m 0.37ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"errors"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"error-ratio"][0m 0.37ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"error-rate"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"frequency"][0m 0.35ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"distance"][0m 0.38ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"cell"][0m 0.34ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[240,"channel"][0m 0.33ms] >> Runtime for discovery module 'wireless': 0.0140 seconds with 131584 bytes >> SNMP: [0/0.00s] MySQL: [24/0.01s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[240][0m 0.28ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[240][0m 0.41ms] communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dot1qTpFdbPort'[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID communityStringIndexing SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v3' '-l' 'authPriv' '-n' "" '-a' 'SHA' '-A' 'PASSWORD' '-u' 'USER' '-x' 'AES' '-X' 'PASSWORD' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vertiv' 'udp:HOSTNAME:161' 'dot1dTpFdbPort'[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.1190 seconds with 3192 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### Modules status: Global+ OS Device #### Load disco module mpls #### >> Runtime for discovery module 'mpls': 0.0000 seconds with 23952 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module mpls #### SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[3.6859999999999999,240][0m 0.98ms] Discovered in 3.686 seconds ./discovery.php [REMOVED] 2021-05-19 08:28:52 - 1 devices discovered in 3.934 secs SNMP [36/2.04s]: Get[12/0.63s] Getnext[1/0.05s] Walk[23/1.36s] MySQL [112/0.09s]: Cell[16/0.01s] Row[0/0.00s] Rows[70/0.05s] Column[4/0.00s] Update[16/0.01s] Insert[1/0.00s] Delete[5/0.01s] RRD [0/0.00s]: