LibreNMS Discovery =================================== Version info: Commit SHA: 5e5684f2cd7077c12663d97ac5e563bdc603d3aa Commit Date: 1505328699 DB Schema: 206 PHP: 7.0.20 MySQL: 5.5.52-MariaDB RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! SQL[[0;33mSELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE '172.31.23.221' ORDER BY device_id DESC[0m] SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '1412'[0m] 172.31.23.221 1412 poweralert SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','0.82','0.90','0.86','1412',NOW())[0m] SNMP Check response code: 0 SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '1412' AND `attrib_type` = 'poll_mib' [0m] Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] POWERALERT 12 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.850.1 | POWERALERT 12 | .1.3.6.1.4.1.850.1 | >> Runtime for discovery module 'os': 0.1250 seconds with 848 bytes #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifDescr[0m] ifDescr.1 = eth0 ifDescr.2 = LOOPBACK SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifName[0m] ifName = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifAlias[0m] ifAlias = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifType[0m] ifType.1 = softwareLoopback ifType.2 = ethernetCsmacd Array ( [1] => Array ( [ifDescr] => eth0 [ifType] => softwareLoopback ) [2] => Array ( [ifDescr] => LOOPBACK [ifType] => ethernetCsmacd ) ) SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '1412' ORDER BY port_id[0m] .. >> Runtime for discovery module 'ports': 12.3800 seconds with 2128 bytes #### Unload disco module ports #### Modules status: Global+ OS+ Device+ #### Load disco module ports-stack #### SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '1412'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifStackStatus[0m] ifStackStatus = No Such Object available on this agent at this OID >> Runtime for discovery module 'ports-stack': 4.0490 seconds with 640 bytes #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device+ #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalEntry = No Such Object available on this agent at this OID entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '1412'[0m] >> Runtime for discovery module 'entity-physical': 0.3000 seconds with 2952 bytes #### Unload disco module entity-physical #### Modules status: Global+ OS+ Device #### Load disco module processors #### hrDevice: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrDevice[0m] hrDevice = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrProcessorLoad[0m] hrProcessorLoad = No Such Object available on this agent at this OID SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '1412' AND `processor_type` != 'ucd-old'[0m] SQL[[0;33mSELECT * FROM `processors` WHERE `device_id` = '1412'[0m] >> Runtime for discovery module 'processors': 7.0370 seconds with 36992 bytes #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '1412' AND `mempool_type` = 'cemp'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '1412'[0m] >> Runtime for discovery module 'mempools': 5.9920 seconds with 24944 bytes #### Unload disco module mempools #### Modules status: Global+ OS+ Device+ #### Load disco module cisco-vrf-lite #### SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '1412' [0m] >> Runtime for discovery module 'cisco-vrf-lite': 0.0010 seconds with 1592 bytes #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device+ #### Load disco module cisco-mac-accounting #### >> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds with 1080 bytes #### Unload disco module cisco-mac-accounting #### Modules status: Global- OS- Device+ #### Load disco module cisco-pw #### >> Runtime for discovery module 'cisco-pw': 0.0000 seconds with 1448 bytes #### Unload disco module cisco-pw #### Modules status: Global- OS- Device+ #### Load disco module cisco-vrf #### >> Runtime for discovery module 'cisco-vrf': 0.0000 seconds with 2008 bytes #### Unload disco module cisco-vrf #### Modules status: Global- OS- Device+ #### Load disco module cisco-cef #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 CISCO-CEF-MIB::cefSwitchingPath[0m] cefSwitchingPath = No Such Object available on this agent at this OID cefSwitchingPath = No Such Object available on this agent at this OID || cefSwitchingPath || || || Array ( ) Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr = No Such Object available on this agent at this OID entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName = No Such Object available on this agent at this OID entPhysicalModelNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalModelName[0m] entPhysicalModelName = No Such Object available on this agent at this OID >> Runtime for discovery module 'cisco-cef': 0.5710 seconds with 2064 bytes #### Unload disco module cisco-cef #### Modules status: Global- OS- Device+ #### Load disco module cisco-sla #### >> Runtime for discovery module 'cisco-sla': 0.0000 seconds with 1760 bytes #### Unload disco module cisco-sla #### Modules status: Global- OS- Device+ #### Load disco module cisco-cbqos #### >> Runtime for discovery module 'cisco-cbqos': 0.0000 seconds with 2768 bytes #### Unload disco module cisco-cbqos #### Modules status: Global- OS- Device+ #### Load disco module cisco-otv #### >> Runtime for discovery module 'cisco-otv': 0.0000 seconds with 4224 bytes #### Unload disco module cisco-otv #### Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex.* 1 ipAdEntIfIndex.* 2 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '1412' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '1412' AND `ifIndex` = '1'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.1/32'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '39802' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '39802'[0m] .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntNetMask.172.31.23.221[0m] * SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '1412' AND `ifIndex` = '2'[0m] SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '1412' AND `ifIndex` = '2'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.31.23.221/24'[0m] SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.31.23.221/24'[0m] sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.31.23.221/24'[0m] SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.31.23.221' AND `ipv4_prefixlen` = '24' AND `port_id` = '39803' [0m] SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.31.23.221' AND `ipv4_prefixlen` = '24' AND `port_id` = '39803'[0m] .SQL[[0;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '1412' OR `ports`.`device_id` IS NULL[0m] >> Runtime for discovery module 'ipv4-addresses': 0.1040 seconds with 31032 bytes #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device+ #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '1412' OR `ports`.`device_id` IS NULL[0m] >> Runtime for discovery module 'ipv6-addresses': 0.1810 seconds with 1120 bytes #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device+ #### Load disco module route #### >> Runtime for discovery module 'route': 0.0000 seconds with 7008 bytes #### Unload disco module route #### Modules status: Global+ OS+ Device #### Load disco module sensors #### Pre-cache poweralert: tlUpsSnmpCardSerialNum SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -m TRIPPLITE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 .1.3.6.1.4.1.850.100.1.1.4.0[0m] 2528AV0AC895C00717 Array ( [poweralert_serial] => 2528AV0AC895C00717 ) ENTITY-SENSOR: Caching OIDs: entPhysicalDescr entPhysicalName entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '1412' AND `attrib_type` = 'ipmi_hostname' [0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'ipmi'[0m] SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'ipmi'[0m] Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] State: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Temperature: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Voltage: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '1412' AND S.poller_type = 'snmp'[0m] >> Runtime for discovery module 'sensors': 0.5600 seconds with 7768 bytes #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m] eqliscsiVolumeEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dfEntry[0m] dfEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '1412' AND `storage_type` != 'dsk'[0m] SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '1412'[0m] >> Runtime for discovery module 'storage': 6.5800 seconds with 3376 bytes #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceEntry = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '1412'[0m] >> Runtime for discovery module 'hr-device': 8.0790 seconds with 800 bytes #### Unload disco module hr-device #### Modules status: Global+ OS+ Device+ #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID Array ( ) LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 lldpRemoteSystemsData[0m] lldpRemoteSystemsData = No Such Object available on this agent at this OID lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData || || || Array ( ) SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID Array ( ) OSPF Discovery: enabled SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='1412'[0m] SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '1412'[0m] >> Runtime for discovery module 'discovery-protocols': 3.6830 seconds with 4432 bytes #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device+ #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] ipNetToPhysicalPhysAddress[1] = 0 ipNetToPhysicalPhysAddress[2] = 0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress[2][*] = bc:16:65:16:6c:6 ipNetToMediaPhysAddress[2][*] = 0:14:f1:27:10:0 SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='1412' AND `context_name`=''[0m] SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '1412' AND `ifIndex` = '1'[0m] eth0: SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '1412' AND `ifIndex` = '2'[0m] LOOPBACK: bc:16:65:16:6c:6 => 172.31.23.6 0:14:f1:27:10:0 => 172.31.23.254 SQL[[0;33mDELETE FROM `ipv4_mac` WHERE `port_id` = '39803' AND `mac_address`='0022bdf819ff' AND `ipv4_address`='172.31.23.253' AND `context_name`=''[0m] SQL[[0;33mDELETE `ipv4_mac` FROM `ipv4_mac` LEFT JOIN `ports` ON `ipv4_mac`.`port_id` = `ports`.`port_id` LEFT JOIN `devices` ON `ipv4_mac`.`device_id` = `devices`.`device_id` WHERE `ports`.`port_id` IS NULL OR `devices`.`device_id` IS NULL[0m] >> Runtime for discovery module 'arp-table': 0.1060 seconds with 28624 bytes #### Unload disco module arp-table #### Modules status: Global- OS- Device+ #### Load disco module discovery-arp #### SQL[[0;33m SELECT * FROM ipv4_mac as m, ports as i WHERE m.port_id = i.port_id AND i.device_id = '1412' AND i.deleted = 0 AND NOT EXISTS ( SELECT * FROM ipv4_addresses a WHERE a.ipv4_address = m.ipv4_address ) GROUP BY ipv4_address ORDER BY ipv4_address [0m] >> Runtime for discovery module 'discovery-arp': 0.0030 seconds with 1000 bytes #### Unload disco module discovery-arp #### Modules status: Global- OS- Device+ #### Load disco module junose-atm-vp #### >> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds with 488 bytes #### Unload disco module junose-atm-vp #### Modules status: Global+ OS+ Device+ #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 .1.3.6.1.2.1.15.2[0m] No Such Object available on this agent at this OID No BGP on hostPeers : SQL[[0;33mSELECT * FROM bgpPeers WHERE device_id = '1412' AND (context_name = '' OR context_name IS NULL)[0m] >> Runtime for discovery module 'bgp-peers': 3.2500 seconds with 2288 bytes #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device+ #### Load disco module vlans #### SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '1412'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 3.5140 seconds with 4456 bytes #### Unload disco module vlans #### Modules status: Global- OS- Device+ #### Load disco module vmware-vminfo #### >> Runtime for discovery module 'vmware-vminfo': 0.0000 seconds with 1000 bytes #### Unload disco module vmware-vminfo #### Modules status: Global- OS- Device+ #### Load disco module libvirt-vminfo #### >> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds with 1816 bytes #### Unload disco module libvirt-vminfo #### Modules status: Global- OS- Device+ #### Load disco module toner #### Checking valid toner ... Array ( ) SQL[[0;33mSELECT * FROM toner WHERE device_id = '1412'[0m] Array ( ) >> Runtime for discovery module 'toner': 0.0000 seconds with 1264 bytes #### Unload disco module toner #### Modules status: Global+ OS+ Device+ #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '1412'[0m] >> Runtime for discovery module 'ucd-diskio': 0.3810 seconds with 736 bytes #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device+ #### Load disco module applications #### Applications: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 nsExtendStatus[0m] nsExtendStatus = No Such Object available on this agent at this OID Available: Checking for: SQL[[0;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='1412' ORDER BY `app_type`[0m] >> Runtime for discovery module 'applications': 0.3810 seconds with 2408 bytes #### Unload disco module applications #### Modules status: Global+ OS+ Device+ #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 352 bytes #### Unload disco module services #### Modules status: Global+ OS+ Device+ #### Load disco module stp #### SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '1412'[0m] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0160 seconds with 3520 bytes #### Unload disco module stp #### Modules status: Global+ OS+ Device+ #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 5.6020 seconds with 144 bytes #### Unload disco module ntp #### Modules status: Global- OS- Device+ #### Load disco module loadbalancers #### >> Runtime for discovery module 'loadbalancers': 3.6950 seconds with 160 bytes #### Unload disco module loadbalancers #### Modules status: Global- OS- Device+ #### Load disco module mef #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m MEF-UNI-EVC-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 MefServiceEvcCfgEntry[0m] mefServiceEvcCfgEntry = No Such Object available on this agent at this OID MEF : SQL[[0;33mSELECT id, mefID, mefIdent FROM mefinfo WHERE device_id = '1412'[0m] >> Runtime for discovery module 'mef': 0.3960 seconds with 1096 bytes #### Unload disco module mef #### Modules status: Global+ OS+ Device+ #### Load disco module wireless #### Attempting to initialize OS: poweralert SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='ap-count'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='clients'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='quality'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='capacity'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='utilization'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='rate'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='ccq'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='snr'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='mse'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='rssi'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='power'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='noise-floor'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='error-ratio'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='error-rate'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='frequency'[0m] SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='1412' AND `sensor_class`='distance'[0m] >> Runtime for discovery module 'wireless': 0.0070 seconds with 132888 bytes #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '1412'[0m] SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '1412'[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 11.6600 seconds with 1848 bytes #### Unload disco module fdb-table #### SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '1412' AND `attrib_type` = 'poll_mib' [0m] SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='69.828' WHERE `device_id` = '1412'[0m] Discovered in 69.828 seconds SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','172.31.23.221','1505346113.1218','69.96','1','DIT-LibreNMS.cchnl.hnl\n')[0m] ./discovery.php 172.31.23.221 2017-09-13 13:43:03 - 1 devices discovered in 69.96 secs SNMP: Get[8/0.18s] Walk [32/52.80s] MySQL: Cell[14/0.01s] Row[7/0.00s] Rows[61/0.05s] Column[1/0.00s] Update[5/0.11s] Insert[2/0.11s] Delete[1/0.01s]