LibreNMS Discovery SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.3ms] SQL[[1;33mSELECT version() [0;33m[][0m 3.78ms] =================================== Version info: Commit SHA: dd39a1ab03b743cb478b8c9eb51476a126b0b83e Commit Date: 1538863691 DB Schema: 268 PHP: 7.2.6 MySQL: 5.5.56-MariaDB RRDTool: 1.4.8 SNMP: NET-SNMP 5.7.2 ==================================DEBUG! Updating os_def.cache... Done SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.1.6.150' ORDER BY device_id DESC [0;33m[][0m 68.11ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[236][0m 0.3ms] 10.1.6.150 236 generic [FPING] /usr/sbin/fping -e -q -c 3 -p 500 -t 500 10.1.6.150 Array ( [xmt] => 3 [rcv] => 3 [loss] => 0 [min] => 0.37 [max] => 14.3 [avg] => 5.51 [exitcode] => 0 ) SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.37","max":"14.3","avg":"5.51","device_id":236}[0m 17.17ms] SNMP Check response code: 0 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Product: MG 1K ESBC ;SW Version: 7.20A.158.012 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.5*.71 | Product: MG 1K ESBC ;SW Version: 7.20A.158.012 | .1.3.6.1.4.1.5003.8.1.1.71 | Device os was updated to audiocodes!SQL[[1;33mUPDATE `devices` set `os`=? WHERE `device_id` = ? [0;33m["audiocodes",236][0m 1.41ms] SQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":236,"device_id":236,"reference":"NULL","type":"system","severity":3,"message":"Device type changed server => network","username":""}[0m 5.65ms] SQL[[1;33mUPDATE `devices` set `type`=? WHERE device_id=? [0;33m["network",236][0m 2.02ms] Device type changed to network! SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[236,"poll_mib"][0m 0.24ms] Attempting to initialize OS: audiocodes Attempting to initialize OS: audiocodes OS initilized as Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m] .*.*.0 = .*.*.0 = .*.4.1.5*.71 .*.*.0 = Product: MG 1K ESBC ;SW Version: 7.20A.158.012 >> Runtime for discovery module 'core': 0.1820 seconds with 1072 bytes >> SNMP: [4/0.93s] MySQL: [7/0.10s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Product: MG 1K ESBC ;SW Version: 7.20A.158.012 SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.5*.71 | Product: MG 1K ESBC ;SW Version: 7.20A.158.012 | .1.3.6.1.4.1.5003.8.1.1.71 | OS: AudiocodesOS (audiocodes) >> Runtime for discovery module 'os': 0.3490 seconds with 1312 bytes >> SNMP: [2/0.35s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ifDescr[0m] ifDescr.1141129729 = Digital DS1 interface 1/1 ifDescr.1141129730 = Digital DS1 interface 1/2 ifDescr.1141129731 = Digital DS1 interface 1/3 ifDescr.1141129732 = Digital DS1 interface 1/4 ifDescr.1142698753 = GigabitEthernet interface 0/1 ifDescr.1142698754 = GigabitEthernet interface 0/2 ifDescr.1142698755 = GigabitEthernet interface 0/3 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ifName[0m] ifName.1141129729 = DS1 Port 1/1 ifName.1141129730 = DS1 Port 1/2 ifName.1141129731 = DS1 Port 1/3 ifName.1141129732 = DS1 Port 1/4 ifName.1142698753 = GigabitEthernet Port 0/1 ifName.1142698754 = GigabitEthernet Port 0/2 ifName.1142698755 = GigabitEthernet Port 0/3 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ifAlias[0m] ifAlias.1141129729 = Interface Alias. ifAlias.1141129730 = Interface Alias. ifAlias.1141129731 = Interface Alias. ifAlias.1141129732 = Interface Alias. ifAlias.1142698753 = GigabitEthernet Port 0/1 ifAlias.1142698754 = GigabitEthernet Port 0/2 ifAlias.1142698755 = GigabitEthernet Port 0/3 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ifType[0m] ifType.1141129729 = ds1 ifType.1141129730 = ds1 ifType.1141129731 = ds1 ifType.1141129732 = ds1 ifType.1142698753 = ethernetCsmacd ifType.1142698754 = ethernetCsmacd ifType.1142698755 = ethernetCsmacd Array ( [1141129729] => Array ( [ifDescr] => Digital DS1 interface 1/1 [ifName] => DS1 Port 1/1 [ifAlias] => Interface Alias. [ifType] => ds1 ) [1141129730] => Array ( [ifDescr] => Digital DS1 interface 1/2 [ifName] => DS1 Port 1/2 [ifAlias] => Interface Alias. [ifType] => ds1 ) [1141129731] => Array ( [ifDescr] => Digital DS1 interface 1/3 [ifName] => DS1 Port 1/3 [ifAlias] => Interface Alias. [ifType] => ds1 ) [1141129732] => Array ( [ifDescr] => Digital DS1 interface 1/4 [ifName] => DS1 Port 1/4 [ifAlias] => Interface Alias. [ifType] => ds1 ) [1142698753] => Array ( [ifDescr] => GigabitEthernet interface 0/1 [ifName] => GigabitEthernet Port 0/1 [ifAlias] => GigabitEthernet Port 0/1 [ifType] => ethernetCsmacd ) [1142698754] => Array ( [ifDescr] => GigabitEthernet interface 0/2 [ifName] => GigabitEthernet Port 0/2 [ifAlias] => GigabitEthernet Port 0/2 [ifType] => ethernetCsmacd ) [1142698755] => Array ( [ifDescr] => GigabitEthernet interface 0/3 [ifName] => GigabitEthernet Port 0/3 [ifAlias] => GigabitEthernet Port 0/3 [ifType] => ethernetCsmacd ) ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[236][0m 1.13ms] ignored by ifType: ds1 (matched: ds1 ) Xignored by ifType: ds1 (matched: ds1 ) Xignored by ifType: ds1 (matched: ds1 ) Xignored by ifType: ds1 (matched: ds1 ) X... >> Runtime for discovery module 'ports': 0.4170 seconds with 4744 bytes >> SNMP: [4/0.42s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '236' [0;33m[][0m 0.98ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ifStackStatus[0m] ifStackStatus = No Such Instance currently exists at this OID >> Runtime for discovery module 'ports-stack': 0.1010 seconds with 1784 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhysicalEntry[0m] entPhysicalDescr.67112960 = Mediant 1000 chassis entPhysicalDescr.67379200 = Mediant-1000 Interfaces' Slot entPhysicalDescr.67387393 = Mediant-1000 Digital Interfaces Module entPhysicalDescr.67387905 = Digital Port entPhysicalDescr.67387906 = Digital Port entPhysicalDescr.67387907 = Digital Port entPhysicalDescr.67387908 = Digital Port entPhysicalDescr.67641344 = Mediant-1000 Interfaces' Slot entPhysicalDescr.67903488 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68165632 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68427776 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68689920 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68952064 = Mediant-1000 CPU's Slot entPhysicalDescr.68956161 = Mediant-1000 CPU Module entPhysicalDescr.68956929 = GigaBit Ethernet Port entPhysicalDescr.68956930 = GigaBit Ethernet Port entPhysicalDescr.68956931 = GigaBit Ethernet Port entPhysicalDescr.69214208 = Mediant-1000 CPU's Slot entPhysicalDescr.69476352 = Mediant-1000 Power Supply's Slot entPhysicalDescr.69738496 = Mediant-1000 Power Supply's Slot entPhysicalDescr.69750785 = Mediant-1000 Power Supply Module entPhysicalDescr.70000640 = Mediant-1000 FAN's Slot entPhysicalDescr.70017025 = Mediant-1000 Fan Module entPhysicalVendorType.67112960 = enterprises.5*.2.1 entPhysicalVendorType.67379200 = enterprises.5*.20.2 entPhysicalVendorType.67387393 = enterprises.5*.20.13 entPhysicalVendorType.67387905 = enterprises.5*.5.3.2 entPhysicalVendorType.67387906 = enterprises.5*.5.3.2 entPhysicalVendorType.67387907 = enterprises.5*.5.3.2 entPhysicalVendorType.67387908 = enterprises.5*.5.3.2 entPhysicalVendorType.67641344 = enterprises.5*.20.2 entPhysicalVendorType.67903488 = enterprises.5*.20.2 entPhysicalVendorType.68165632 = enterprises.5*.20.2 entPhysicalVendorType.68427776 = enterprises.5*.20.2 entPhysicalVendorType.68689920 = enterprises.5*.20.2 entPhysicalVendorType.68952064 = enterprises.5*.20.1 entPhysicalVendorType.68956161 = enterprises.5*.20.11 entPhysicalVendorType.68956929 = enterprises.5*.5.3.6 entPhysicalVendorType.68956930 = enterprises.5*.5.3.6 entPhysicalVendorType.68956931 = enterprises.5*.5.3.6 entPhysicalVendorType.69214208 = enterprises.5*.20.1 entPhysicalVendorType.69476352 = enterprises.5*.20.3 entPhysicalVendorType.69738496 = enterprises.5*.20.3 entPhysicalVendorType.69750785 = enterprises.5*.20.14 entPhysicalVendorType.70000640 = enterprises.5*.20.4 entPhysicalVendorType.70017025 = enterprises.5*.20.15 entPhysicalContainedIn.67112960 = 0 entPhysicalContainedIn.67379200 = 67112960 entPhysicalContainedIn.67387393 = 67379200 entPhysicalContainedIn.67387905 = 67387393 entPhysicalContainedIn.67387906 = 67387393 entPhysicalContainedIn.67387907 = 67387393 entPhysicalContainedIn.67387908 = 67387393 entPhysicalContainedIn.67641344 = 67112960 entPhysicalContainedIn.67903488 = 67112960 entPhysicalContainedIn.68165632 = 67112960 entPhysicalContainedIn.68427776 = 67112960 entPhysicalContainedIn.68689920 = 67112960 entPhysicalContainedIn.68952064 = 67112960 entPhysicalContainedIn.68956161 = 68952064 entPhysicalContainedIn.68956929 = 68956161 entPhysicalContainedIn.68956930 = 68956161 entPhysicalContainedIn.68956931 = 68956161 entPhysicalContainedIn.69214208 = 67112960 entPhysicalContainedIn.69476352 = 67112960 entPhysicalContainedIn.69738496 = 67112960 entPhysicalContainedIn.69750785 = 69738496 entPhysicalContainedIn.70000640 = 67112960 entPhysicalContainedIn.70017025 = 70000640 entPhysicalClass.67112960 = chassis entPhysicalClass.67379200 = container entPhysicalClass.67387393 = module entPhysicalClass.67387905 = port entPhysicalClass.67387906 = port entPhysicalClass.67387907 = port entPhysicalClass.67387908 = port entPhysicalClass.67641344 = container entPhysicalClass.67903488 = container entPhysicalClass.68165632 = container entPhysicalClass.68427776 = container entPhysicalClass.68689920 = container entPhysicalClass.68952064 = container entPhysicalClass.68956161 = module entPhysicalClass.68956929 = port entPhysicalClass.68956930 = port entPhysicalClass.68956931 = port entPhysicalClass.69214208 = container entPhysicalClass.69476352 = container entPhysicalClass.69738496 = container entPhysicalClass.69750785 = powerSupply entPhysicalClass.70000640 = container entPhysicalClass.70017025 = fan entPhysicalParentRelPos.67112960 = 0 entPhysicalParentRelPos.67379200 = 1 entPhysicalParentRelPos.67387393 = 1 entPhysicalParentRelPos.67387905 = 1 entPhysicalParentRelPos.67387906 = 2 entPhysicalParentRelPos.67387907 = 3 entPhysicalParentRelPos.67387908 = 4 entPhysicalParentRelPos.67641344 = 2 entPhysicalParentRelPos.67903488 = 3 entPhysicalParentRelPos.68165632 = 4 entPhysicalParentRelPos.68427776 = 5 entPhysicalParentRelPos.68689920 = 6 entPhysicalParentRelPos.68952064 = 7 entPhysicalParentRelPos.68956161 = 1 entPhysicalParentRelPos.68956929 = 1 entPhysicalParentRelPos.68956930 = 2 entPhysicalParentRelPos.68956931 = 3 entPhysicalParentRelPos.69214208 = 8 entPhysicalParentRelPos.69476352 = 9 entPhysicalParentRelPos.69738496 = 10 entPhysicalParentRelPos.69750785 = 1 entPhysicalParentRelPos.70000640 = 11 entPhysicalParentRelPos.70017025 = 1 entPhysicalName.67112960 = Default Physical Name entPhysicalName.67379200 = Default Physical Name entPhysicalName.67387393 = Digital Module Slot no.1 entPhysicalName.67387905 = 1 entPhysicalName.67387906 = 2 entPhysicalName.67387907 = 3 entPhysicalName.67387908 = 4 entPhysicalName.67641344 = Default Physical Name entPhysicalName.67903488 = Default Physical Name entPhysicalName.68165632 = Default Physical Name entPhysicalName.68427776 = Default Physical Name entPhysicalName.68689920 = Default Physical Name entPhysicalName.68952064 = Default Physical Name entPhysicalName.68956161 = CPU Module no.1 entPhysicalName.68956929 = 1 entPhysicalName.68956930 = 2 entPhysicalName.68956931 = 3 entPhysicalName.69214208 = Default Physical Name entPhysicalName.69476352 = Default Physical Name entPhysicalName.69738496 = Default Physical Name entPhysicalName.69750785 = Power-Supply no.2 entPhysicalName.70000640 = Default Physical Name entPhysicalName.70017025 = Fan-Tray no.1 entPhysicalHardwareRev.67112960 = entPhysicalHardwareRev.67379200 = entPhysicalHardwareRev.67387393 = entPhysicalHardwareRev.67387905 = entPhysicalHardwareRev.67387906 = entPhysicalHardwareRev.67387907 = entPhysicalHardwareRev.67387908 = entPhysicalHardwareRev.67641344 = entPhysicalHardwareRev.67903488 = entPhysicalHardwareRev.68165632 = entPhysicalHardwareRev.68427776 = entPhysicalHardwareRev.68689920 = entPhysicalHardwareRev.68952064 = entPhysicalHardwareRev.68956161 = entPhysicalHardwareRev.68956929 = entPhysicalHardwareRev.68956930 = entPhysicalHardwareRev.68956931 = entPhysicalHardwareRev.69214208 = entPhysicalHardwareRev.69476352 = entPhysicalHardwareRev.69738496 = entPhysicalHardwareRev.69750785 = entPhysicalHardwareRev.70000640 = entPhysicalHardwareRev.70017025 = entPhysicalFirmwareRev.67112960 = entPhysicalFirmwareRev.67379200 = entPhysicalFirmwareRev.67387393 = entPhysicalFirmwareRev.67387905 = entPhysicalFirmwareRev.67387906 = entPhysicalFirmwareRev.67387907 = entPhysicalFirmwareRev.67387908 = entPhysicalFirmwareRev.67641344 = entPhysicalFirmwareRev.67903488 = entPhysicalFirmwareRev.68165632 = entPhysicalFirmwareRev.68427776 = entPhysicalFirmwareRev.68689920 = entPhysicalFirmwareRev.68952064 = entPhysicalFirmwareRev.68956161 = entPhysicalFirmwareRev.68956929 = entPhysicalFirmwareRev.68956930 = entPhysicalFirmwareRev.68956931 = entPhysicalFirmwareRev.69214208 = entPhysicalFirmwareRev.69476352 = entPhysicalFirmwareRev.69738496 = entPhysicalFirmwareRev.69750785 = entPhysicalFirmwareRev.70000640 = entPhysicalFirmwareRev.70017025 = entPhysicalSoftwareRev.67112960 = entPhysicalSoftwareRev.67379200 = entPhysicalSoftwareRev.67387393 = entPhysicalSoftwareRev.67387905 = entPhysicalSoftwareRev.67387906 = entPhysicalSoftwareRev.67387907 = entPhysicalSoftwareRev.67387908 = entPhysicalSoftwareRev.67641344 = entPhysicalSoftwareRev.67903488 = entPhysicalSoftwareRev.68165632 = entPhysicalSoftwareRev.68427776 = entPhysicalSoftwareRev.68689920 = entPhysicalSoftwareRev.68952064 = entPhysicalSoftwareRev.68956161 = entPhysicalSoftwareRev.68956929 = entPhysicalSoftwareRev.68956930 = entPhysicalSoftwareRev.68956931 = entPhysicalSoftwareRev.69214208 = entPhysicalSoftwareRev.69476352 = entPhysicalSoftwareRev.69738496 = entPhysicalSoftwareRev.69750785 = entPhysicalSoftwareRev.70000640 = entPhysicalSoftwareRev.70017025 = entPhysicalSerialNum.67112960 = 10981627 entPhysicalSerialNum.67379200 = entPhysicalSerialNum.67387393 = entPhysicalSerialNum.67387905 = entPhysicalSerialNum.67387906 = entPhysicalSerialNum.67387907 = entPhysicalSerialNum.67387908 = entPhysicalSerialNum.67641344 = entPhysicalSerialNum.67903488 = entPhysicalSerialNum.68165632 = entPhysicalSerialNum.68427776 = entPhysicalSerialNum.68689920 = entPhysicalSerialNum.68952064 = entPhysicalSerialNum.68956161 = entPhysicalSerialNum.68956929 = entPhysicalSerialNum.68956930 = entPhysicalSerialNum.68956931 = entPhysicalSerialNum.69214208 = entPhysicalSerialNum.69476352 = entPhysicalSerialNum.69738496 = entPhysicalSerialNum.69750785 = entPhysicalSerialNum.70000640 = entPhysicalSerialNum.70017025 = entPhysicalMfgName.67112960 = Mediant 1000 entPhysicalMfgName.67379200 = entPhysicalMfgName.67387393 = entPhysicalMfgName.67387905 = entPhysicalMfgName.67387906 = entPhysicalMfgName.67387907 = entPhysicalMfgName.67387908 = entPhysicalMfgName.67641344 = entPhysicalMfgName.67903488 = entPhysicalMfgName.68165632 = entPhysicalMfgName.68427776 = entPhysicalMfgName.68689920 = entPhysicalMfgName.68952064 = entPhysicalMfgName.68956161 = entPhysicalMfgName.68956929 = entPhysicalMfgName.68956930 = entPhysicalMfgName.68956931 = entPhysicalMfgName.69214208 = entPhysicalMfgName.69476352 = entPhysicalMfgName.69738496 = entPhysicalMfgName.69750785 = entPhysicalMfgName.70000640 = entPhysicalMfgName.70017025 = entPhysicalModelName.67112960 = entPhysicalModelName.67379200 = entPhysicalModelName.67387393 = entPhysicalModelName.67387905 = entPhysicalModelName.67387906 = entPhysicalModelName.67387907 = entPhysicalModelName.67387908 = entPhysicalModelName.67641344 = entPhysicalModelName.67903488 = entPhysicalModelName.68165632 = entPhysicalModelName.68427776 = entPhysicalModelName.68689920 = entPhysicalModelName.68952064 = entPhysicalModelName.68956161 = entPhysicalModelName.68956929 = entPhysicalModelName.68956930 = entPhysicalModelName.68956931 = entPhysicalModelName.69214208 = entPhysicalModelName.69476352 = entPhysicalModelName.69738496 = entPhysicalModelName.69750785 = entPhysicalModelName.70000640 = entPhysicalModelName.70017025 = entPhysicalAlias.67112960 = Chassis default Alias string. entPhysicalAlias.67379200 = entPhysicalAlias.67387393 = entPhysicalAlias.67387905 = entPhysicalAlias.67387906 = entPhysicalAlias.67387907 = entPhysicalAlias.67387908 = entPhysicalAlias.67641344 = entPhysicalAlias.67903488 = entPhysicalAlias.68165632 = entPhysicalAlias.68427776 = entPhysicalAlias.68689920 = entPhysicalAlias.68952064 = entPhysicalAlias.68956161 = entPhysicalAlias.68956929 = entPhysicalAlias.68956930 = entPhysicalAlias.68956931 = entPhysicalAlias.69214208 = entPhysicalAlias.69476352 = entPhysicalAlias.69738496 = entPhysicalAlias.69750785 = entPhysicalAlias.70000640 = entPhysicalAlias.70017025 = entPhysicalAssetID.67112960 = Chassis default Alias string. entPhysicalAssetID.67379200 = entPhysicalAssetID.67387393 = entPhysicalAssetID.67387905 = entPhysicalAssetID.67387906 = entPhysicalAssetID.67387907 = entPhysicalAssetID.67387908 = entPhysicalAssetID.67641344 = entPhysicalAssetID.67903488 = entPhysicalAssetID.68165632 = entPhysicalAssetID.68427776 = entPhysicalAssetID.68689920 = entPhysicalAssetID.68952064 = entPhysicalAssetID.68956161 = entPhysicalAssetID.68956929 = entPhysicalAssetID.68956930 = entPhysicalAssetID.68956931 = entPhysicalAssetID.69214208 = entPhysicalAssetID.69476352 = entPhysicalAssetID.69738496 = entPhysicalAssetID.69750785 = entPhysicalAssetID.70000640 = entPhysicalAssetID.70017025 = entPhysicalIsFRU.67112960 = false entPhysicalIsFRU.67379200 = false entPhysicalIsFRU.67387393 = true entPhysicalIsFRU.67387905 = false entPhysicalIsFRU.67387906 = false entPhysicalIsFRU.67387907 = false entPhysicalIsFRU.67387908 = false entPhysicalIsFRU.67641344 = false entPhysicalIsFRU.67903488 = false entPhysicalIsFRU.68165632 = false entPhysicalIsFRU.68427776 = false entPhysicalIsFRU.68689920 = false entPhysicalIsFRU.68952064 = false entPhysicalIsFRU.68956161 = true entPhysicalIsFRU.68956929 = false entPhysicalIsFRU.68956930 = false entPhysicalIsFRU.68956931 = false entPhysicalIsFRU.69214208 = false entPhysicalIsFRU.69476352 = false entPhysicalIsFRU.69738496 = false entPhysicalIsFRU.69750785 = true entPhysicalIsFRU.70000640 = false entPhysicalIsFRU.70017025 = true entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entAliasMappingIdentifier[0m] entAliasMappingIdentifier.67387905.0 = ifIndex.1141129729 entAliasMappingIdentifier.67387906.0 = ifIndex.1141129730 entAliasMappingIdentifier.67387907.0 = ifIndex.1141129731 entAliasMappingIdentifier.67387908.0 = ifIndex.1141129732 entAliasMappingIdentifier.68956929.0 = ifIndex.1142698753 entAliasMappingIdentifier.68956930.0 = ifIndex.1142698754 entAliasMappingIdentifier.68956931.0 = ifIndex.1142698755 SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67112960][0m 0.4ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67112960,"Mediant 1000 chassis","chassis","Default Physical Name","","10981627","0","Mediant 1000","0","enterprises.5003.8.1.2.2.1","","","","false","Chassis default Alias string.","Chassis default Alias string.",236,67112960][0m 24.68ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67379200][0m 0.29ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67379200,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","1","enterprises.5003.8.1.2.20.2","","","","false","","",236,67379200][0m 5.42ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67387393][0m 1.02ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67387393,"Mediant-1000 Digital Interfaces Module","module","Digital Module Slot no.1","","","67379200","","1","enterprises.5003.8.1.2.20.13","","","","true","","",236,67387393][0m 7.24ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67387905][0m 1.42ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67387905,"Digital Port","port","1","","","67387393","","1","enterprises.5003.8.1.2.5.3.2","","","","false","","",236,67387905][0m 3.63ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67387906][0m 2.28ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67387906,"Digital Port","port","2","","","67387393","","2","enterprises.5003.8.1.2.5.3.2","","","","false","","",236,67387906][0m 0.97ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67387907][0m 0.33ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67387907,"Digital Port","port","3","","","67387393","","3","enterprises.5003.8.1.2.5.3.2","","","","false","","",236,67387907][0m 1.07ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67387908][0m 1.82ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67387908,"Digital Port","port","4","","","67387393","","4","enterprises.5003.8.1.2.5.3.2","","","","false","","",236,67387908][0m 16.03ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67641344][0m 0.5ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67641344,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","2","enterprises.5003.8.1.2.20.2","","","","false","","",236,67641344][0m 3.54ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,67903488][0m 0.31ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[67903488,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","3","enterprises.5003.8.1.2.20.2","","","","false","","",236,67903488][0m 1.32ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68165632][0m 0.25ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68165632,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","4","enterprises.5003.8.1.2.20.2","","","","false","","",236,68165632][0m 2.86ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68427776][0m 0.26ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68427776,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","5","enterprises.5003.8.1.2.20.2","","","","false","","",236,68427776][0m 2.85ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68689920][0m 0.32ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68689920,"Mediant-1000 Interfaces' Slot","container","Default Physical Name","","","67112960","","6","enterprises.5003.8.1.2.20.2","","","","false","","",236,68689920][0m 1.54ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68952064][0m 0.29ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68952064,"Mediant-1000 CPU's Slot","container","Default Physical Name","","","67112960","","7","enterprises.5003.8.1.2.20.1","","","","false","","",236,68952064][0m 2.67ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68956161][0m 1.2ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68956161,"Mediant-1000 CPU Module","module","CPU Module no.1","","","68952064","","1","enterprises.5003.8.1.2.20.11","","","","true","","",236,68956161][0m 12.96ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68956929][0m 0.84ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68956929,"GigaBit Ethernet Port","port","1","","","68956161","","1","enterprises.5003.8.1.2.5.3.6","","","","false","","",236,68956929][0m 2.81ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68956930][0m 0.21ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68956930,"GigaBit Ethernet Port","port","2","","","68956161","","2","enterprises.5003.8.1.2.5.3.6","","","","false","","",236,68956930][0m 5.91ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,68956931][0m 1.89ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[68956931,"GigaBit Ethernet Port","port","3","","","68956161","","3","enterprises.5003.8.1.2.5.3.6","","","","false","","",236,68956931][0m 10.69ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,69214208][0m 2.93ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[69214208,"Mediant-1000 CPU's Slot","container","Default Physical Name","","","67112960","","8","enterprises.5003.8.1.2.20.1","","","","false","","",236,69214208][0m 1.73ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,69476352][0m 0.33ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[69476352,"Mediant-1000 Power Supply's Slot","container","Default Physical Name","","","67112960","","9","enterprises.5003.8.1.2.20.3","","","","false","","",236,69476352][0m 14.73ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,69738496][0m 1.05ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[69738496,"Mediant-1000 Power Supply's Slot","container","Default Physical Name","","","67112960","","10","enterprises.5003.8.1.2.20.3","","","","false","","",236,69738496][0m 8.41ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,69750785][0m 0.28ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[69750785,"Mediant-1000 Power Supply Module","powerSupply","Power-Supply no.2","","","69738496","","1","enterprises.5003.8.1.2.20.14","","","","true","","",236,69750785][0m 3.19ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,70000640][0m 0.32ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[70000640,"Mediant-1000 FAN's Slot","container","Default Physical Name","","","67112960","","11","enterprises.5003.8.1.2.20.4","","","","false","","",236,70000640][0m 3.27ms] .SQL[[1;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = ? AND entPhysicalIndex = ? [0;33m[236,70017025][0m 2.64ms] SQL[[1;33mUPDATE `entPhysical` set `entPhysicalIndex`=?,`entPhysicalDescr`=?,`entPhysicalClass`=?,`entPhysicalName`=?,`entPhysicalModelName`=?,`entPhysicalSerialNum`=?,`entPhysicalContainedIn`=?,`entPhysicalMfgName`=?,`entPhysicalParentRelPos`=?,`entPhysicalVendorType`=?,`entPhysicalHardwareRev`=?,`entPhysicalFirmwareRev`=?,`entPhysicalSoftwareRev`=?,`entPhysicalIsFRU`=?,`entPhysicalAlias`=?,`entPhysicalAssetID`=? WHERE device_id=? AND entPhysicalIndex=? [0;33m[70017025,"Mediant-1000 Fan Module","fan","Fan-Tray no.1","","","70000640","","1","enterprises.5003.8.1.2.20.15","","","","true","","",236,70017025][0m 2.12ms] . SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[236][0m 1.16ms] >> Runtime for discovery module 'entity-physical': 0.8860 seconds with 9904 bytes >> SNMP: [1/0.66s] MySQL: [24/0.14s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrProcessorLoad[0m] hrProcessorLoad.1 = 58 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrDeviceDescr[0m] hrDeviceDescr.1 = CPU-Cavium hrDeviceDescr.2 = OAM interface hrDeviceDescr.3 = RAM hrDeviceDescr.4 = Flash Discovered LibreNMS\Device\Processor Array ( [processor_id] => [entPhysicalIndex] => 0 [hrDeviceIndex] => 1 [device_id] => 236 [processor_oid] => .1.3.6.1.2.1.25.3.3.1.2.1 [processor_index] => 1 [processor_type] => hr [processor_usage] => 58 [processor_descr] => CPU-Cavium [processor_precision] => 1 [processor_perc_warn] => 75 ) SQL[[1;33mSELECT * FROM `processors` WHERE device_id=? AND processor_index=? AND processor_type=? [0;33m[236,"1","hr"][0m 0.32ms] .SQL[[1;33mSELECT * FROM `processors` WHERE device_id=? AND processor_index=? AND processor_type=? [0;33m[236,"1","hr"][0m 0.21ms] .SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? AND `processor_id` NOT IN (?,?) [0;33m[236,526,526][0m 0.25ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.57ms] >> Runtime for discovery module 'processors': 0.2040 seconds with 133912 bytes >> SNMP: [2/0.20s] MySQL: [4/0.00s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[236][0m 0.23ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] hpLocalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] hpGlobalMem = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageIndex.1 = 1 hrStorageIndex.2 = 2 hrStorageType.1 = hrStorageRam hrStorageType.2 = hrStorageFlashMemory hrStorageDescr.1 = Internal RAM hrStorageDescr.2 = Internal Flash hrStorageAllocationUnits.1 = 1 hrStorageAllocationUnits.2 = 1 hrStorageSize.1 = 512 hrStorageSize.2 = 67108864 hrStorageUsed.1 = 0 hrStorageUsed.2 = 0 hrStorageAllocationFailures.1 = 0 hrStorageAllocationFailures.2 = 0 hrStorage : Discover Mempool: 1, hrstorage, Internal RAM, 1, , SQL[[1;33mSELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = ? AND `device_id` = ? AND `mempool_type` = ? [0;33m[1,236,"hrstorage"][0m 0.44ms] .SQL[[1;33mUPDATE `mempools` set `mempool_descr`=? WHERE device_id=? AND mempool_index=? AND mempool_type=? [0;33m["Internal RAM",236,1,"hrstorage"][0m 1.81ms] Array ( [hrstorage] => Array ( [1] => 1 ) ) SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '236' [0;33m[][0m 1.18ms] 1 -> hrstorage >> Runtime for discovery module 'mempools': 0.3930 seconds with 35176 bytes >> SNMP: [3/0.39s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[236][0m 0.21ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2664 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipAdEntIfIndex[0m] ipAdEntIfIndex No Such Instance currently exists at this OID SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipAdEntNetMask.[0m] No Such Instance currently exists at this OID SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[236,null][0m 0.25ms] !SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[236][0m 4.56ms] >> Runtime for discovery module 'ipv4-addresses': 0.1690 seconds with 33416 bytes >> SNMP: [2/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipv6AddrPfxLength[0m] .*.*.8.1.2 No Such Object available on this agent at this OID SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[236][0m 1.63ms] >> Runtime for discovery module 'ipv6-addresses': 0.1030 seconds with 3472 bytes >> SNMP: [2/0.10s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhysicalDescr[0m] entPhysicalDescr.67112960 = Mediant 1000 chassis entPhysicalDescr.67379200 = Mediant-1000 Interfaces' Slot entPhysicalDescr.67387393 = Mediant-1000 Digital Interfaces Module entPhysicalDescr.67387905 = Digital Port entPhysicalDescr.67387906 = Digital Port entPhysicalDescr.67387907 = Digital Port entPhysicalDescr.67387908 = Digital Port entPhysicalDescr.67641344 = Mediant-1000 Interfaces' Slot entPhysicalDescr.67903488 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68165632 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68427776 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68689920 = Mediant-1000 Interfaces' Slot entPhysicalDescr.68952064 = Mediant-1000 CPU's Slot entPhysicalDescr.68956161 = Mediant-1000 CPU Module entPhysicalDescr.68956929 = GigaBit Ethernet Port entPhysicalDescr.68956930 = GigaBit Ethernet Port entPhysicalDescr.68956931 = GigaBit Ethernet Port entPhysicalDescr.69214208 = Mediant-1000 CPU's Slot entPhysicalDescr.69476352 = Mediant-1000 Power Supply's Slot entPhysicalDescr.69738496 = Mediant-1000 Power Supply's Slot entPhysicalDescr.69750785 = Mediant-1000 Power Supply Module entPhysicalDescr.70000640 = Mediant-1000 FAN's Slot entPhysicalDescr.70017025 = Mediant-1000 Fan Module entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhysicalName[0m] entPhysicalName.67112960 = Default Physical Name entPhysicalName.67379200 = Default Physical Name entPhysicalName.67387393 = Digital Module Slot no.1 entPhysicalName.67387905 = 1 entPhysicalName.67387906 = 2 entPhysicalName.67387907 = 3 entPhysicalName.67387908 = 4 entPhysicalName.67641344 = Default Physical Name entPhysicalName.67903488 = Default Physical Name entPhysicalName.68165632 = Default Physical Name entPhysicalName.68427776 = Default Physical Name entPhysicalName.68689920 = Default Physical Name entPhysicalName.68952064 = Default Physical Name entPhysicalName.68956161 = CPU Module no.1 entPhysicalName.68956929 = 1 entPhysicalName.68956930 = 2 entPhysicalName.68956931 = 3 entPhysicalName.69214208 = Default Physical Name entPhysicalName.69476352 = Default Physical Name entPhysicalName.69738496 = Default Physical Name entPhysicalName.69750785 = Power-Supply no.2 entPhysicalName.70000640 = Default Physical Name entPhysicalName.70017025 = Fan-Tray no.1 entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhySensorType[0m] entPhySensorType = No Such Object available on this agent at this OID entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhySensorScale[0m] entPhySensorScale = No Such Object available on this agent at this OID entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhySensorPrecision[0m] entPhySensorPrecision = No Such Object available on this agent at this OID entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhySensorValue[0m] entPhySensorValue = No Such Object available on this agent at this OID entPhySensorOperStatusSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 entPhySensorOperStatus[0m] entPhySensorOperStatus = No Such Object available on this agent at this OID SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[236,"ipmi_hostname"][0m 0.36ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",236,"ipmi"][0m 0.4ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",236,"ipmi"][0m 0.33ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",236,"ipmi"][0m 0.31ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",236,"ipmi"][0m 0.31ms] Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",236,"snmp"][0m 0.33ms] Current: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",236,"snmp"][0m 0.32ms] Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",236,"snmp"][0m 1.64ms] Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",236,"snmp"][0m 0.33ms] Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",236,"snmp"][0m 0.34ms] Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",236,"snmp"][0m 0.31ms] Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",236,"snmp"][0m 0.33ms] Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",236,"snmp"][0m 0.31ms] Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",236,"snmp"][0m 0.32ms] Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",236,"snmp"][0m 0.36ms] Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",236,"snmp"][0m 0.32ms] State: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",236,"snmp"][0m 0.32ms] Temperature: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",236,"snmp"][0m 0.32ms] Voltage: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",236,"snmp"][0m 0.33ms] Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",236,"snmp"][0m 0.33ms] Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",236,"snmp"][0m 0.32ms] Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",236,"snmp"][0m 0.33ms] Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",236,"snmp"][0m 31.1ms] Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",236,"snmp"][0m 0.37ms] Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",236,"snmp"][0m 0.32ms] Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",236,"snmp"][0m 8.58ms] Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",236,"snmp"][0m 0.35ms] Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",236,"snmp"][0m 0.35ms] >> Runtime for discovery module 'sensors': 0.5130 seconds with 64904 bytes >> SNMP: [7/0.46s] MySQL: [28/0.05s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrStorageEntry[0m] hrStorageIndex.1 = 1 hrStorageIndex.2 = 2 hrStorageType.1 = hrStorageRam hrStorageType.2 = hrStorageFlashMemory hrStorageDescr.1 = Internal RAM hrStorageDescr.2 = Internal Flash hrStorageAllocationUnits.1 = 1 hrStorageAllocationUnits.2 = 1 hrStorageSize.1 = 512 hrStorageSize.2 = 67108864 hrStorageUsed.1 = 0 hrStorageUsed.2 = 0 hrStorageAllocationFailures.1 = 0 hrStorageAllocationFailures.2 = 0 hrStorage : Discover Storage: 2, hrStorageFlashMemory, hrstorage, Internal Flash, 67108864, 1, 0 SQL[[1;33mSELECT * FROM `storage` WHERE `storage_index` = ? AND `device_id` = ? AND `storage_mib` = ? [0;33m[2,236,"hrstorage"][0m 0.43ms] SQL[[1;33mUPDATE `storage` set `storage_descr`=?,`storage_type`=?,`storage_units`=?,`storage_size`=? WHERE `device_id` = ? AND `storage_index` = ? AND `storage_mib` = ? [0;33m["Internal Flash","hrStorageFlashMemory","1",67108864,236,2,"hrstorage"][0m 2.79ms] .SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dskTable[0m] dskTable = No Such Object available on this agent at this OID SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '236' AND `storage_type` != 'dsk' [0;33m[][0m 0.27ms] Array ( [hrstorage] => Array ( [2] => 1 ) ) SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '236' [0;33m[][0m 0.19ms] 2 -> hrstorage >> Runtime for discovery module 'storage': 0.1800 seconds with 11720 bytes >> SNMP: [2/0.17s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrDeviceEntry[0m] hrDeviceIndex.1 = 1 hrDeviceIndex.2 = 2 hrDeviceIndex.3 = 3 hrDeviceIndex.4 = 4 hrDeviceType.1 = hrDeviceProcessor hrDeviceType.2 = hrDeviceNetwork hrDeviceType.3 = hrDeviceVolatileMemory hrDeviceType.4 = hrDeviceNonVolatileMemory hrDeviceDescr.1 = CPU-Cavium hrDeviceDescr.2 = OAM interface hrDeviceDescr.3 = RAM hrDeviceDescr.4 = Flash hrDeviceID.1 = enterprises.5*.71 hrDeviceID.2 = enterprises.5*.71 hrDeviceID.3 = enterprises.5*.71 hrDeviceID.4 = enterprises.5*.71 hrDeviceStatus.1 = running hrDeviceStatus.2 = running hrDeviceStatus.3 = running hrDeviceStatus.4 = running hrDeviceErrors.1 = 0 hrDeviceErrors.2 = 0 hrDeviceErrors.3 = 0 hrDeviceErrors.4 = 0 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 hrProcessorEntry[0m] hrProcessorFrwID.1 = enterprises.5*.71 hrProcessorLoad.1 = 38 Array ( [1] => Array ( [hrDeviceIndex] => 1 [hrDeviceType] => hrDeviceProcessor [hrDeviceDescr] => CPU-Cavium [hrDeviceID] => enterprises.5003.8.1.1.71 [hrDeviceStatus] => running [hrDeviceErrors] => 0 [hrProcessorFrwID] => enterprises.5003.8.1.1.71 [hrProcessorLoad] => 38 ) [2] => Array ( [hrDeviceIndex] => 2 [hrDeviceType] => hrDeviceNetwork [hrDeviceDescr] => OAM interface [hrDeviceID] => enterprises.5003.8.1.1.71 [hrDeviceStatus] => running [hrDeviceErrors] => 0 ) [3] => Array ( [hrDeviceIndex] => 3 [hrDeviceType] => hrDeviceVolatileMemory [hrDeviceDescr] => RAM [hrDeviceID] => enterprises.5003.8.1.1.71 [hrDeviceStatus] => running [hrDeviceErrors] => 0 ) [4] => Array ( [hrDeviceIndex] => 4 [hrDeviceType] => hrDeviceNonVolatileMemory [hrDeviceDescr] => Flash [hrDeviceID] => enterprises.5003.8.1.1.71 [hrDeviceStatus] => running [hrDeviceErrors] => 0 ) ) SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[236,"1"][0m 0.51ms] SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=?,`hrProcessorLoad`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceProcessor","CPU-Cavium","running","0","38",236,"1"][0m 2.25ms] .SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[236,"2"][0m 0.27ms] SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceNetwork","OAM interface","running","0",236,"2"][0m 5.17ms] .SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[236,"3"][0m 0.34ms] SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceVolatileMemory","RAM","running","0",236,"3"][0m 2.31ms] .SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[236,"4"][0m 0.45ms] SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceNonVolatileMemory","Flash","running","0",236,"4"][0m 1.84ms] .SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '236' [0;33m[][0m 0.49ms] >> Runtime for discovery module 'hr-device': 0.1780 seconds with 8840 bytes >> SNMP: [2/0.16s] MySQL: [5/0.01s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 cdpCache[0m] cdpCache = No Such Object available on this agent at this OID LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 lldpRemTable[0m] lldpRemTable = No Such Object available on this agent at this OID OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[236][0m 1.71ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[236][0m 0.45ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.44ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.1460 seconds with 4688 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] ipNetToMediaPhysAddress = No Such Instance currently exists at this OID SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[236,""][0m 6.41ms] SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 19.3ms] >> Runtime for discovery module 'arp-table': 0.1400 seconds with 2248 bytes >> SNMP: [0/0.00s] MySQL: [2/0.03s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 bgpLocalAs[0m] 4:9:10:13.50 No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[236,""][0m 0.18ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[236,""][0m 0.43ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[236][0m 0.21ms] >> Runtime for discovery module 'bgp-peers': 0.0640 seconds with 5624 bytes >> SNMP: [1/0.06s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[236][0m 1.32ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] dot1dBasePortIfIndex = No Such Object available on this agent at this OID IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'vlans': 0.2400 seconds with 9304 bytes >> SNMP: [2/0.24s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 diskIOEntry[0m] diskIOEntry = No Such Object available on this agent at this OID Array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '236' [0;33m[][0m 6.66ms] >> Runtime for discovery module 'ucd-diskio': 0.0700 seconds with 3160 bytes >> SNMP: [1/0.06s] MySQL: [1/0.01s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[236][0m 2.66ms] SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] No Such Object available on this agent at this OID >> Runtime for discovery module 'stp': 0.0420 seconds with 5792 bytes >> SNMP: [1/0.04s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"ap-count"][0m 1.2ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"clients"][0m 0.24ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"quality"][0m 0.22ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"capacity"][0m 0.96ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"utilization"][0m 0.22ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"rate"][0m 0.28ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"ccq"][0m 0.23ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"snr"][0m 0.22ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"ssr"][0m 8.19ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"mse"][0m 1.1ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"rssi"][0m 0.22ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"power"][0m 0.29ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"noise-floor"][0m 0.24ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"errors"][0m 2.28ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"error-ratio"][0m 0.23ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"error-rate"][0m 0.28ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"frequency"][0m 0.85ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[236,"distance"][0m 0.28ms] >> Runtime for discovery module 'wireless': 0.0200 seconds with 123048 bytes >> SNMP: [0/0.00s] MySQL: [18/0.02s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[236][0m 0.87ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[236][0m 0.16ms] SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dot1qTpFdbPort[0m] dot1qTpFdbPort = No Such Object available on this agent at this OID SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/audiocodes udp:HOSTNAME:161 dot1dTpFdbPort[0m] dot1dTpFdbPort = No Such Object available on this agent at this OID >> Runtime for discovery module 'fdb-table': 0.1890 seconds with 3048 bytes >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[236,"poll_mib"][0m 0.37ms] SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[6.4459999999999997,236][0m 7.51ms] Discovered in 6.446 seconds SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.1.6.150","start":1539007354.2842951,"duration":"9.189","devices":1,"poller":"librenms.ua.com.ar"}[0m 5.92ms] ./discovery.php 10.1.6.150 2018-10-08 11:02:43 - 1 devices discovered in 9.189 secs SNMP [36/4.42s]: Get[9/1.55s] Getnext[1/0.06s] Walk[26/2.80s] MySQL [111/0.39s]: Cell[31/0.03s] Row[-24/-0.02s] Rows[62/0.17s] Column[2/0.00s] Update[32/0.17s] Insert[3/0.03s] Delete[5/0.02s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]