LibreNMS Discovery SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.37ms] SQL[[1;33mSELECT version() [0;33m[][0m 0.25ms] =================================== Version info: Commit SHA: 01e8a6e0896ce1916a8492e1a1219c09da10c700 Commit Date: 1535060429 DB Schema: 260 PHP: 7.0.30-0ubuntu0.16.04.1 MySQL: 10.0.34-MariaDB-0ubuntu0.16.04.1 RRDTool: 1.5.5 SNMP: NET-SNMP 5.7.3 ==================================DEBUG! Updating os_def.cache... Done SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.1.1.16' ORDER BY device_id DESC [0;33m[][0m 0.94ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[150][0m 0.21ms] 10.1.1.16 150 generic [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500 10.1.1.16 Array ( [xmt] => 3 [rcv] => 3 [loss] => 0 [min] => 5.05 [max] => 8.71 [avg] => 6.71 [exitcode] => 0 ) SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"5.05","max":"8.71","avg":"6.71","device_id":150}[0m 38.38ms] SNMP Check response code: 0 SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.33333 | Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent | .1.3.6.1.4.1.33333 | SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m] SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[150,"poll_mib"][0m 0.38ms] Attempting to initialize OS: generic OS initialized: LibreNMS\OS\Generic Modules status: Global+ OS Device #### Load disco module core #### SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m] .*.*.0 = PEMRIDGE .*.*.0 = .*.4.1.33333 .*.*.0 = Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent SQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":150,"device_id":150,"reference":"NULL","type":"system","severity":3,"message":"sysObjectID -> .1.3.6.1.4.1.33333","username":""}[0m 53.37ms] SQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":150,"device_id":150,"reference":"NULL","type":"system","severity":3,"message":"sysName -> pemridge","username":""}[0m 41.99ms] SQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":150,"device_id":150,"reference":"NULL","type":"system","severity":3,"message":"sysDescr -> Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent","username":""}[0m 36.26ms] SQL[[1;33mUPDATE `devices` set `sysObjectID`=?,`sysName`=?,`sysDescr`=? WHERE device_id=? [0;33m[".1.3.6.1.4.1.33333","pemridge","Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent",150][0m 42.09ms] >> Runtime for discovery module 'core': 0.2100 seconds with 3992 bytes >> SNMP: [5/0.12s] MySQL: [8/0.22s] RRD: [0/0.00s] #### Unload disco module core #### Modules status: Global+ OS+ Device #### Load disco module os #### SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m] Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m] .*.4.1.33333 | Morningstar Corporation TriStar MPPT Charge Controller SNMP Agent | .1.3.6.1.4.1.33333 | SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m] OS: Generic Device (generic) >> Runtime for discovery module 'os': 0.0560 seconds with 1392 bytes >> SNMP: [3/0.05s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module os #### Modules status: Global+ OS+ Device #### Load disco module ports #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType[0m] End of MIB Array ( ) SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[150][0m 0.95ms] >> Runtime for discovery module 'ports': 0.1440 seconds with 4000 bytes >> SNMP: [4/0.14s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports #### Modules status: Global+ OS+ Device #### Load disco module ports-stack #### SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '150' [0;33m[][0m 0.39ms] SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus[0m] End of MIB >> Runtime for discovery module 'ports-stack': 0.0310 seconds with 1784 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ports-stack #### Modules status: Global+ OS+ Device #### Load disco module entity-physical #### Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry[0m] End of MIB SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[150][0m 0.99ms] >> Runtime for discovery module 'entity-physical': 0.0550 seconds with 5216 bytes >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module entity-physical #### Modules status: Global- OS- Device Module [ entity-state ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module processors #### No YAML Discovery data. Host Resources: SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad[0m] End of MIB UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[150][0m 1.07ms] SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[150][0m 0.72ms] SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[150][0m 0.94ms] SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.2021.11.11.0[0m] SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[150][0m 1.05ms] SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 3.07ms] >> Runtime for discovery module 'processors': 0.0610 seconds with 73408 bytes >> SNMP: [2/0.05s] MySQL: [5/0.01s] RRD: [0/0.00s] #### Unload disco module processors #### Modules status: Global+ OS+ Device #### Load disco module mempools #### SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[150][0m 0.67ms] SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] End of MIB SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '150' [0;33m[][0m 0.5ms] >> Runtime for discovery module 'mempools': 0.1290 seconds with 28520 bytes >> SNMP: [3/0.12s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module mempools #### Modules status: Global+ OS+ Device #### Load disco module cisco-vrf-lite #### SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[150][0m 0.29ms] >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2664 bytes >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module cisco-vrf-lite #### Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os. Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os. Modules status: Global- OS- Device Module [ vrf ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os. Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os. Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os. Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ipv4-addresses #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex[0m] End of MIB SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.[0m] SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[150,null][0m 0.39ms] !SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[150][0m 1.23ms] >> Runtime for discovery module 'ipv4-addresses': 0.0560 seconds with 33504 bytes >> SNMP: [2/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv4-addresses #### Modules status: Global+ OS+ Device #### Load disco module ipv6-addresses #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength[0m] End of MIB SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[150][0m 0.52ms] >> Runtime for discovery module 'ipv6-addresses': 0.0570 seconds with 3472 bytes >> SNMP: [2/0.06s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ipv6-addresses #### Modules status: Global- OS- Device Module [ route ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module sensors #### ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr[0m] End of MIB SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[150,"ipmi_hostname"][0m 0.41ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",150,"ipmi"][0m 0.64ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",150,"ipmi"][0m 0.62ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",150,"ipmi"][0m 0.66ms] SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",150,"ipmi"][0m 0.69ms] Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",150,"snmp"][0m 0.72ms] Current: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",150,"snmp"][0m 0.7ms] Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",150,"snmp"][0m 0.59ms] Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",150,"snmp"][0m 0.63ms] Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",150,"snmp"][0m 0.6ms] Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",150,"snmp"][0m 0.59ms] Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",150,"snmp"][0m 0.61ms] Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",150,"snmp"][0m 0.6ms] Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",150,"snmp"][0m 0.78ms] Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",150,"snmp"][0m 0.58ms] Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",150,"snmp"][0m 0.61ms] State: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",150,"snmp"][0m 0.59ms] Temperature: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",150,"snmp"][0m 0.64ms] Voltage: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",150,"snmp"][0m 0.59ms] Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",150,"snmp"][0m 0.59ms] Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",150,"snmp"][0m 0.59ms] Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",150,"snmp"][0m 0.6ms] Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",150,"snmp"][0m 0.64ms] Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",150,"snmp"][0m 0.6ms] Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",150,"snmp"][0m 0.66ms] Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",150,"snmp"][0m 0.62ms] Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",150,"snmp"][0m 0.78ms] Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",150,"snmp"][0m 0.59ms] >> Runtime for discovery module 'sensors': 0.0560 seconds with 39024 bytes >> SNMP: [1/0.03s] MySQL: [28/0.02s] RRD: [0/0.00s] #### Unload disco module sensors #### Modules status: Global+ OS+ Device #### Load disco module storage #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable[0m] End of MIB SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '150' AND `storage_type` != 'dsk' [0;33m[][0m 0.77ms] SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '150' [0;33m[][0m 0.37ms] >> Runtime for discovery module 'storage': 0.0730 seconds with 14256 bytes >> SNMP: [2/0.07s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module storage #### Modules status: Global+ OS+ Device #### Load disco module hr-device #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry[0m] End of MIB Array ( ) SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '150' [0;33m[][0m 0.59ms] >> Runtime for discovery module 'hr-device': 0.0710 seconds with 3744 bytes >> SNMP: [2/0.07s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module hr-device #### Modules status: Global+ OS+ Device #### Load disco module discovery-protocols #### CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache[0m] End of MIB SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[150,"End of MIB"][0m 3.31ms] Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/discovery-protocols.inc.php on line 49 LLDP-MIB: SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemTable[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpLocPortId[0m] End of MIB Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/discovery-protocols.inc.php on line 166 OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[150][0m 0.81ms] SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[150][0m 0.68ms] SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.13ms] 0 orphaned links deleted >> Runtime for discovery module 'discovery-protocols': 0.1450 seconds with 5112 bytes >> SNMP: [0/0.00s] MySQL: [4/0.01s] RRD: [0/0.00s] #### Unload disco module discovery-protocols #### Modules status: Global+ OS+ Device #### Load disco module arp-table #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m] End of MIB SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m] End of MIB SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[150,""][0m 2.15ms] SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[150,"End of MIB"][0m 0.34ms] Warning: Illegal string offset 'ipNetToMediaPhysAddress' in /opt/librenms/includes/discovery/arp-table.inc.php on line 59 Warning: Illegal string offset 'ipNetToPhysicalPhysAddress' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60 Warning: Illegal string offset 'ipv4' in /opt/librenms/includes/discovery/arp-table.inc.php on line 60 : SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 3.35ms] >> Runtime for discovery module 'arp-table': 0.0820 seconds with 3440 bytes >> SNMP: [0/0.00s] MySQL: [3/0.01s] RRD: [0/0.00s] #### Unload disco module arp-table #### Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os. Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module bgp-peers #### SNMP[[0;36m/usr/bin/snmpgetnext -v1 -c COMMUNITY -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 bgpLocalAs[0m] No BGP on hostPeers : SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[150,""][0m 0.45ms] SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[150,""][0m 0.22ms] SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[150][0m 0.3ms] >> Runtime for discovery module 'bgp-peers': 0.0190 seconds with 5584 bytes >> SNMP: [1/0.02s] MySQL: [2/0.00s] RRD: [0/0.00s] #### Unload disco module bgp-peers #### Modules status: Global+ OS+ Device #### Load disco module vlans #### SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[150][0m 0.3ms] SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] End of MIB IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m] >> Runtime for discovery module 'vlans': 0.0660 seconds with 9304 bytes >> SNMP: [2/0.07s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module vlans #### Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os. Modules status: Global- OS- Device Module [ toner ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module ucd-diskio #### SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry[0m] End of MIB Array ( ) SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '150' [0;33m[][0m 0.54ms] >> Runtime for discovery module 'ucd-diskio': 0.0320 seconds with 3160 bytes >> SNMP: [1/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module ucd-diskio #### Modules status: Global- OS- Device Module [ applications ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module services #### >> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module services #### Modules status: Global+ OS+ Device #### Load disco module stp #### SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[150][0m 0.35ms] SNMP[[0;36m/usr/bin/snmpget -v1 -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m] >> Runtime for discovery module 'stp': 0.0180 seconds with 5824 bytes >> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s] #### Unload disco module stp #### Modules status: Global+ OS+ Device #### Load disco module ntp #### >> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s] #### Unload disco module ntp #### Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os. Modules status: Global- OS- Device Module [ mef ] disabled on os. Modules status: Global+ OS+ Device #### Load disco module wireless #### SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"ap-count"][0m 3.99ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"clients"][0m 0.77ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"quality"][0m 0.45ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"capacity"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"utilization"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"rate"][0m 0.44ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"ccq"][0m 0.44ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"snr"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"ssr"][0m 0.43ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"mse"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"rssi"][0m 0.4ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"power"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"noise-floor"][0m 0.47ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"errors"][0m 0.4ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"error-ratio"][0m 0.4ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"error-rate"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"frequency"][0m 0.41ms] SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[150,"distance"][0m 0.42ms] >> Runtime for discovery module 'wireless': 0.0160 seconds with 123072 bytes >> SNMP: [0/0.00s] MySQL: [18/0.01s] RRD: [0/0.00s] #### Unload disco module wireless #### Modules status: Global+ OS+ Device #### Load disco module fdb-table #### SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[150][0m 0.41ms] SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[150][0m 0.31ms] SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qTpFdbPort[0m] End of MIB Q-BRIDGE-MIB:SNMP[[0;36m/usr/bin/snmpwalk -v1 -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m] End of MIB Warning: Illegal string offset 'dot1dBasePortIfIndex' in /opt/librenms/includes/discovery/fdb-table/bridge.inc.php on line 48 SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[150,""][0m 0.64ms] Warning: Illegal string offset 'dot1qTpFdbPort' in /opt/librenms/includes/discovery/fdb-table/bridge.inc.php on line 54 Warning: Invalid argument supplied for foreach() in /opt/librenms/includes/discovery/fdb-table/bridge.inc.php on line 54 >> Runtime for discovery module 'fdb-table': 0.0760 seconds with 3528 bytes >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s] #### Unload disco module fdb-table #### SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[150,"poll_mib"][0m 0.19ms] SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[2.612,150][0m 18.97ms] Discovered in 2.612 seconds SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller) [0;33m{"type":"discover","doing":"10.1.1.16","start":1535131427.0317,"duration":"2.960","devices":1,"poller":"librenms"}[0m 35.98ms] ./discovery.php 10.1.1.16 2018-08-24 10:23:50 - 1 devices discovered in 2.960 secs SNMP [32/0.96s]: Get[12/0.27s] Getnext[1/0.02s] Walk[19/0.68s] MySQL [86/0.34s]: Cell[3/0.00s] Row[5/0.01s] Rows[64/0.05s] Column[2/0.00s] Update[2/0.06s] Insert[5/0.21s] Delete[5/0.01s] RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]