- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: e814cd8e34a73c2441ca8eaf34cf7025bf26e2b3
- Commit Date: 1522115417
- DB Schema: 247
- PHP: 7.0.28-0ubuntu0.16.04.1
- MySQL: 10.0.34-MariaDB-0ubuntu0.16.04.1
- RRDTool: 1.5.5
- SNMP: NET-SNMP 5.7.3
- ==================================DEBUG!
- Updating os_def.cache... Done
- SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE 'ata.bertie.nz' ORDER BY device_id DESC[0m]
- SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '5'[0m]
- ata.bertie.nz 5 linux SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('3','3','0','3.09','3.24','3.18','5',NOW())[0m]
- SNMP Check response code: 0
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '5' AND `attrib_type` = 'poll_mib' [0m]
- Attempting to initialize OS: linux
- Attempting to initialize OS: unix
- OS initilized as Generic
- Modules status: Global+ OS Device
- #### Load disco module core ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUQn -m SNMPv2-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 sysName.0 sysObjectID.0 sysDescr.0[0m]
- .*.*.0 = ata
- .*.*.0 = .*.*.*.1.3
- .*.*.0 = Linux ata * #1 PREEMPT Wed Aug 2 14:04:45 CST 2017 armv5tejl
- >> Runtime for discovery module 'core': 0.0430 seconds with 1088 bytes
- >> SNMP: [2/0.07s] MySQL: [8/0.12s] RRD: [0/0.00s]
- #### Unload disco module core ####
- Modules status: Global+ OS+ Device
- #### Load disco module os ####
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
- Linux ata * #1 PREEMPT Wed Aug 2 14:04:45 CST 2017 armv5tejl
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
- .*.*.*.1.3
- | Linux ata 2.6.26.5 #1 PREEMPT Wed Aug 2 14:04:45 CST 2017 armv5tejl | .1.3.6.1.4.1.9.6.1.23.1.1.1.3 |
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m SYNOLOGY-SYSTEM-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/synology udp:HOSTNAME:161 systemStatus.0[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0[0m]
- "console=ttyS1,115200n8 rootfstype=squashfs noalign half_image=0 verify=y Hw_Model=SPA112 Router_Mode=0
- "
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 GANDI-MIB::rxCounter.0[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqnv -m IEEE802dot11-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot11manufacturerName[0m]
- No Such Object available on this agent at this OID
- OS: Linux (linux)
- >> Runtime for discovery module 'os': 0.2510 seconds with 2008 bytes
- >> SNMP: [7/0.25s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module os ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifDescr[0m]
- ifDescr.1 = lo
- ifDescr.2 = eth0
- ifDescr.6 = br0
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifName[0m]
- ifName.1 = lo
- ifName.2 = eth0
- ifName.6 = br0
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifAlias[0m]
- ifAlias.1 =
- ifAlias.2 =
- ifAlias.6 =
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifType[0m]
- ifType.1 = softwareLoopback
- ifType.2 = ethernetCsmacd
- ifType.6 = ethernetCsmacd
- Array
- (
- [1] => Array
- (
- [ifDescr] => lo
- [ifName] => lo
- [ifAlias] =>
- [ifType] => softwareLoopback
- )
- [2] => Array
- (
- [ifDescr] => eth0
- [ifName] => eth0
- [ifAlias] =>
- [ifType] => ethernetCsmacd
- )
- [6] => Array
- (
- [ifDescr] => br0
- [ifName] => br0
- [ifAlias] =>
- [ifType] => ethernetCsmacd
- )
- )
- SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m]
- SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '5' ORDER BY port_id[0m]
- ...
- >> Runtime for discovery module 'ports': 0.1870 seconds with 4336 bytes
- >> SNMP: [4/0.18s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports ####
- Modules status: Global+ OS+ Device
- #### Load disco module ports-stack ####
- SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '5'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ifStackStatus[0m]
- >> Runtime for discovery module 'ports-stack': 0.0180 seconds with 1768 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ports-stack ####
- Modules status: Global+ OS+ Device
- #### Load disco module entity-physical ####
- Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalEntry[0m]
- entPhysicalIndex.1 = 0
- entPhysicalIndex.2 = 1
- entPhysicalDescr.1 = SPA112, 2 FXS
- entPhysicalDescr.2 = ARM926EJ-S rev 5 (v5l)
- entPhysicalVendorType.1 = cevChassisSRP527
- entPhysicalVendorType.2 = zeroDotZero
- entPhysicalContainedIn.1 = 0
- entPhysicalContainedIn.2 = 1
- entPhysicalClass.1 = chassis
- entPhysicalClass.2 = cpu
- entPhysicalParentRelPos.1 = 0
- entPhysicalParentRelPos.2 = 0
- entPhysicalName.1 = SPA112
- entPhysicalName.2 = ARM926EJ-S
- entPhysicalHardwareRev.1 = V01
- entPhysicalHardwareRev.2 = v5l
- entPhysicalFirmwareRev.1 = 0.00.51
- entPhysicalFirmwareRev.2 = 5
- entPhysicalSoftwareRev.1 = 0.00.51
- entPhysicalSoftwareRev.2 = 0000
- entPhysicalSerialNum.1 =
- entPhysicalSerialNum.2 = 0000000000000000
- entPhysicalMfgName.1 = CISCO
- entPhysicalMfgName.2 =
- entPhysicalModelName.1 = SPA112
- entPhysicalModelName.2 = NXP PNX8181
- entPhysicalAlias.1 =
- entPhysicalAlias.2 =
- entPhysicalAssetID.1 =
- entPhysicalAssetID.2 = 5
- entPhysicalIsFRU.1 = false
- entPhysicalIsFRU.2 = false
- entPhysicalMfgDate.1 =
- entPhysicalMfgDate.2 =
- entPhysicalUris.1 = ""
- entPhysicalUris.2 = ""
- entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
- entAliasMappingIdentifier.1 = zeroDotZero
- SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '5' AND entPhysicalIndex = '1'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='1',`entPhysicalDescr` ='SPA112, 2 FXS',`entPhysicalClass` ='chassis',`entPhysicalName` ='SPA112',`entPhysicalModelName` ='SPA112',`entPhysicalSerialNum` ='',`entPhysicalContainedIn` ='0',`entPhysicalMfgName` ='CISCO',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='cevChassisSRP527',`entPhysicalHardwareRev` ='V01',`entPhysicalFirmwareRev` ='0.00.51',`entPhysicalSoftwareRev` ='0.00.51',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='' WHERE device_id='5' AND entPhysicalIndex='1'[0m]
- .SQL[[0;33mSELECT entPhysical_id FROM `entPhysical` WHERE device_id = '5' AND entPhysicalIndex = '2'[0m]
- SQL[[0;33mUPDATE `entPhysical` set `entPhysicalIndex` ='2',`entPhysicalDescr` ='ARM926EJ-S rev 5 (v5l)',`entPhysicalClass` ='cpu',`entPhysicalName` ='ARM926EJ-S',`entPhysicalModelName` ='NXP PNX8181',`entPhysicalSerialNum` ='0000000000000000',`entPhysicalContainedIn` ='1',`entPhysicalMfgName` ='',`entPhysicalParentRelPos` ='0',`entPhysicalVendorType` ='zeroDotZero',`entPhysicalHardwareRev` ='v5l',`entPhysicalFirmwareRev` ='5',`entPhysicalSoftwareRev` ='0000',`entPhysicalIsFRU` ='false',`entPhysicalAlias` ='',`entPhysicalAssetID` ='5' WHERE device_id='5' AND entPhysicalIndex='2'[0m]
- .
- SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '5'[0m]
- >> Runtime for discovery module 'entity-physical': 0.1990 seconds with 8936 bytes
- >> SNMP: [1/0.12s] MySQL: [5/0.02s] RRD: [0/0.00s]
- #### Unload disco module entity-physical ####
- Modules status: Global- OS- Device Module [ entity-state ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module processors ####
- No YAML Discovery data.
- Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrProcessorLoad[0m]
- hrProcessorLoad.196608 = 2
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrDeviceDescr[0m]
- hrDeviceDescr.196608 =
- hrDeviceDescr.262145 = network interface lo
- hrDeviceDescr.262146 = network interface eth0
- hrDeviceDescr.262150 = network interface br0
- hrDeviceDescr.786432 = Guessing that there's a floating point co-processor
- Discovered LibreNMS\Device\Processor Array
- (
- [processor_id] =>
- [entPhysicalIndex] => 0
- [hrDeviceIndex] => 196608
- [device_id] => 5
- [processor_oid] => .1.3.6.1.2.1.25.3.3.1.2.196608
- [processor_index] => 196608
- [processor_type] => hr
- [processor_usage] => 2
- [processor_descr] => Processor
- [processor_precision] => 1
- [processor_perc_warn] => 75
- )
- SQL[[0;33mSELECT * FROM `processors` WHERE device_id='5' AND processor_index='196608' AND processor_type='hr'[0m]
- .SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`='5' AND `processor_id` NOT IN ('139')[0m]
- SQL[[0;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'processors': 0.2310 seconds with 60376 bytes
- >> SNMP: [2/0.23s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module processors ####
- Modules status: Global+ OS+ Device
- #### Load disco module mempools ####
- SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '5' AND `mempool_type` = 'cemp'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
- hpLocalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
- hpGlobalMem = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageIndex.1 = 1
- hrStorageIndex.3 = 3
- hrStorageIndex.6 = 6
- hrStorageIndex.7 = 7
- hrStorageIndex.8 = 8
- hrStorageIndex.10 = 10
- hrStorageType.1 = hrStorageRam
- hrStorageType.3 = hrStorageVirtualMemory
- hrStorageType.6 = hrStorageOther
- hrStorageType.7 = hrStorageOther
- hrStorageType.8 = hrStorageOther
- hrStorageType.10 = hrStorageVirtualMemory
- hrStorageDescr.1 = Physical memory
- hrStorageDescr.3 = Virtual memory
- hrStorageDescr.6 = Memory buffers
- hrStorageDescr.7 = Cached memory
- hrStorageDescr.8 = Shared memory
- hrStorageDescr.10 = Swap space
- hrStorageAllocationUnits.1 = 1024
- hrStorageAllocationUnits.3 = 1024
- hrStorageAllocationUnits.6 = 1024
- hrStorageAllocationUnits.7 = 1024
- hrStorageAllocationUnits.8 = 1024
- hrStorageAllocationUnits.10 = 1024
- hrStorageSize.1 = 28416
- hrStorageSize.3 = 28416
- hrStorageSize.6 = 28416
- hrStorageSize.7 = 7708
- hrStorageSize.8 = 0
- hrStorageSize.10 = 0
- hrStorageUsed.1 = 27116
- hrStorageUsed.3 = 27116
- hrStorageUsed.6 = 988
- hrStorageUsed.7 = 7708
- hrStorageUsed.8 = 0
- hrStorageUsed.10 = 0
- hrStorage : Discover Mempool: 1, hrstorage, Physical memory, 1024, ,
- SQL[[0;33mSELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '1' AND `device_id` = '5' AND `mempool_type` = 'hrstorage'[0m]
- .SQL[[0;33mUPDATE `mempools` set `mempool_descr` ='Physical memory' WHERE device_id='5' AND mempool_index='1' AND mempool_type='hrstorage'[0m]
- Discover Mempool: 3, hrstorage, Virtual memory, 1024, ,
- SQL[[0;33mSELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '3' AND `device_id` = '5' AND `mempool_type` = 'hrstorage'[0m]
- .SQL[[0;33mUPDATE `mempools` set `mempool_descr` ='Virtual memory' WHERE device_id='5' AND mempool_index='3' AND mempool_type='hrstorage'[0m]
- Discover Mempool: 10, hrstorage, Swap space, 1024, ,
- SQL[[0;33mSELECT COUNT(mempool_id) FROM `mempools` WHERE `mempool_index` = '10' AND `device_id` = '5' AND `mempool_type` = 'hrstorage'[0m]
- .SQL[[0;33mUPDATE `mempools` set `mempool_descr` ='Swap space' WHERE device_id='5' AND mempool_index='10' AND mempool_type='hrstorage'[0m]
- Array
- (
- [hrstorage] => Array
- (
- [1] => 1
- [3] => 1
- [10] => 1
- )
- )
- SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id` = '5'[0m]
- 1 -> hrstorage
- 3 -> hrstorage
- 10 -> hrstorage
- >> Runtime for discovery module 'mempools': 0.2820 seconds with 44296 bytes
- >> SNMP: [3/0.23s] MySQL: [8/0.04s] RRD: [0/0.00s]
- #### Unload disco module mempools ####
- Modules status: Global+ OS+ Device
- #### Load disco module cisco-vrf-lite ####
- SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '5' [0m]
- >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2696 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module cisco-vrf-lite ####
- Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
- Modules status: Global- OS- Device Module [ vrf ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
- Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ipv4-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntIfIndex[0m]
- ipAdEntIfIndex.* 1
- ipAdEntIfIndex.* 6
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m]
- *
- SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '5' AND `ifIndex` = '1'[0m]
- SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '5' AND `ifIndex` = '1'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/8'[0m]
- SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.1/8'[0m]
- sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/8'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '19' [0m]
- SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '8' AND `port_id` = '19'[0m]
- .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAdEntNetMask.192.168.88.3[0m]
- *
- SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '5' AND `ifIndex` = '6'[0m]
- SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '5' AND `ifIndex` = '6'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.88.3/24'[0m]
- SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '192.168.88.3/24'[0m]
- sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '192.168.88.3/24'[0m]
- SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '192.168.88.3' AND `ipv4_prefixlen` = '24' AND `port_id` = '21' [0m]
- SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '192.168.88.3' AND `ipv4_prefixlen` = '24' AND `port_id` = '21'[0m]
- .SQL[[0;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '5' OR `ports`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'ipv4-addresses': 0.2010 seconds with 34936 bytes
- >> SNMP: [3/0.13s] MySQL: [15/0.07s] RRD: [0/0.00s]
- #### Unload disco module ipv4-addresses ####
- Modules status: Global+ OS+ Device
- #### Load disco module ipv6-addresses ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
- ipAddressIfIndex.ipv6 No Such Instance currently exists at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
- .*.*.8.1.2 No Such Object available on this agent at this OID
- SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '5' OR `ports`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'ipv6-addresses': 0.1280 seconds with 3376 bytes
- >> SNMP: [2/0.13s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ipv6-addresses ####
- Modules status: Global- OS- Device Module [ route ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- Pre-cache linux: RaspberryPi SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121[0m]
- iso.*.1.8*.*.*.*.121 = No Such Object available on this agent at this OID
- Array
- (
- [raspberry_pi_sensors] => Array
- (
- )
- )
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalDescr[0m]
- entPhysicalDescr.1 = SPA112, 2 FXS
- entPhysicalDescr.2 = ARM926EJ-S rev 5 (v5l)
- entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhysicalName[0m]
- entPhysicalName.1 = SPA112
- entPhysicalName.2 = ARM926EJ-S
- entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorType[0m]
- entPhySensorType = No Such Object available on this agent at this OID
- entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorScale[0m]
- entPhySensorScale = No Such Object available on this agent at this OID
- entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorPrecision[0m]
- entPhySensorPrecision = No Such Object available on this agent at this OID
- entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 entPhySensorValue[0m]
- entPhySensorValue = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '5' AND `attrib_type` = 'ipmi_hostname' [0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'ipmi'[0m]
- Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Charge: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.1[0m]
- No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Fanspeed: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmFanSensorsDevice[0m]
- .*.4.1.2*.1.2 No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='raspberry_freq' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Load: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.8[0m]
- No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Runtime: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.3[0m]
- No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- State: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Temperature: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmTempSensorsDevice[0m]
- .*.4.1.2*.1.2 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqve -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.1[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osqn -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3[0m]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Voltage: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m LM-SENSORS-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lmVoltSensorsDevice[0m]
- .*.4.1.2*.1.2 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OsqnU -m SUPERMICRO-HEALTH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.10876.2.1.1.1.1.3[0m]
- .*.4.1.108*.1.1.3 No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.4[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.5[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.6[0m]
- No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Osqnv -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 .1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.7[0m]
- No Such Object available on this agent at this OID
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='rasbperry_volts' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Delay: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Quality_factor: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Chromatic_dispersion: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Ber: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Eer: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='eer' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- Waterflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='waterflow' AND S.device_id = D.device_id AND D.device_id = '5' AND S.poller_type = 'snmp'[0m]
- >> Runtime for discovery module 'sensors': 0.8820 seconds with 59512 bytes
- >> SNMP: [20/0.86s] MySQL: [28/0.02s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- Modules status: Global+ OS+ Device
- #### Load disco module storage ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m]
- eqliscsiVolumeEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CPQHOST-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/hp udp:HOSTNAME:161 cpqHoFileSysEntry[0m]
- cpqHoFileSysEntry = No Such Object available on this agent at this OID
- HPE ILO4 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrStorageEntry[0m]
- hrStorageIndex.1 = 1
- hrStorageIndex.3 = 3
- hrStorageIndex.6 = 6
- hrStorageIndex.7 = 7
- hrStorageIndex.8 = 8
- hrStorageIndex.10 = 10
- hrStorageType.1 = hrStorageRam
- hrStorageType.3 = hrStorageVirtualMemory
- hrStorageType.6 = hrStorageOther
- hrStorageType.7 = hrStorageOther
- hrStorageType.8 = hrStorageOther
- hrStorageType.10 = hrStorageVirtualMemory
- hrStorageDescr.1 = Physical memory
- hrStorageDescr.3 = Virtual memory
- hrStorageDescr.6 = Memory buffers
- hrStorageDescr.7 = Cached memory
- hrStorageDescr.8 = Shared memory
- hrStorageDescr.10 = Swap space
- hrStorageAllocationUnits.1 = 1024
- hrStorageAllocationUnits.3 = 1024
- hrStorageAllocationUnits.6 = 1024
- hrStorageAllocationUnits.7 = 1024
- hrStorageAllocationUnits.8 = 1024
- hrStorageAllocationUnits.10 = 1024
- hrStorageSize.1 = 28416
- hrStorageSize.3 = 28416
- hrStorageSize.6 = 28416
- hrStorageSize.7 = 7708
- hrStorageSize.8 = 0
- hrStorageSize.10 = 0
- hrStorageUsed.1 = 27116
- hrStorageUsed.3 = 27116
- hrStorageUsed.6 = 988
- hrStorageUsed.7 = 7708
- hrStorageUsed.8 = 0
- hrStorageUsed.10 = 0
- hrStorage : SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dfEntry[0m]
- dfEntry = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NIMBLE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 volEntry[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dskTable[0m]
- dskTable = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '5' AND `storage_type` != 'dsk'[0m]
- SQL[[0;33mSELECT * FROM `storage` WHERE `device_id` = '5'[0m]
- >> Runtime for discovery module 'storage': 0.3790 seconds with 13592 bytes
- >> SNMP: [5/0.33s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module storage ####
- Modules status: Global+ OS+ Device
- #### Load disco module hr-device ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrDeviceEntry[0m]
- hrDeviceIndex.196608 = 196608
- hrDeviceIndex.262145 = 262145
- hrDeviceIndex.262146 = 262146
- hrDeviceIndex.262150 = 262150
- hrDeviceIndex.786432 = 786432
- hrDeviceType.196608 = hrDeviceProcessor
- hrDeviceType.262145 = hrDeviceNetwork
- hrDeviceType.262146 = hrDeviceNetwork
- hrDeviceType.262150 = hrDeviceNetwork
- hrDeviceType.786432 = hrDeviceCoprocessor
- hrDeviceDescr.196608 =
- hrDeviceDescr.262145 = network interface lo
- hrDeviceDescr.262146 = network interface eth0
- hrDeviceDescr.262150 = network interface br0
- hrDeviceDescr.786432 = Guessing that there's a floating point co-processor
- hrDeviceID.196608 = zeroDotZero
- hrDeviceID.262145 = zeroDotZero
- hrDeviceID.262146 = zeroDotZero
- hrDeviceID.262150 = zeroDotZero
- hrDeviceID.786432 = zeroDotZero
- hrDeviceStatus.262145 = running
- hrDeviceStatus.262146 = running
- hrDeviceStatus.262150 = running
- hrDeviceErrors.262145 = 0
- hrDeviceErrors.262146 = 0
- hrDeviceErrors.262150 = 0
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 hrProcessorEntry[0m]
- hrProcessorFrwID.196608 = zeroDotZero
- hrProcessorLoad.196608 = 2
- Array
- (
- [196608] => Array
- (
- [hrDeviceIndex] => 196608
- [hrDeviceType] => hrDeviceProcessor
- [hrDeviceDescr] =>
- [hrDeviceID] => zeroDotZero
- [hrProcessorFrwID] => zeroDotZero
- [hrProcessorLoad] => 2
- )
- [262145] => Array
- (
- [hrDeviceIndex] => 262145
- [hrDeviceType] => hrDeviceNetwork
- [hrDeviceDescr] => network interface lo
- [hrDeviceID] => zeroDotZero
- [hrDeviceStatus] => running
- [hrDeviceErrors] => 0
- )
- [262146] => Array
- (
- [hrDeviceIndex] => 262146
- [hrDeviceType] => hrDeviceNetwork
- [hrDeviceDescr] => network interface eth0
- [hrDeviceID] => zeroDotZero
- [hrDeviceStatus] => running
- [hrDeviceErrors] => 0
- )
- [262150] => Array
- (
- [hrDeviceIndex] => 262150
- [hrDeviceType] => hrDeviceNetwork
- [hrDeviceDescr] => network interface br0
- [hrDeviceID] => zeroDotZero
- [hrDeviceStatus] => running
- [hrDeviceErrors] => 0
- )
- [786432] => Array
- (
- [hrDeviceIndex] => 786432
- [hrDeviceType] => hrDeviceCoprocessor
- [hrDeviceDescr] => Guessing that there's a floating point co-processor
- [hrDeviceID] => zeroDotZero
- )
- )
- SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '5' AND hrDeviceIndex = '196608'[0m]
- SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceProcessor',`hrDeviceDescr` ='',`hrDeviceStatus` ='',`hrDeviceErrors` ='',`hrProcessorLoad` ='2' WHERE device_id='5' AND hrDeviceIndex='196608'[0m]
- .SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '5' AND hrDeviceIndex = '262145'[0m]
- SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceNetwork',`hrDeviceDescr` ='network interface lo',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0' WHERE device_id='5' AND hrDeviceIndex='262145'[0m]
- .SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '5' AND hrDeviceIndex = '262146'[0m]
- SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceNetwork',`hrDeviceDescr` ='network interface eth0',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0' WHERE device_id='5' AND hrDeviceIndex='262146'[0m]
- .SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '5' AND hrDeviceIndex = '262150'[0m]
- SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceNetwork',`hrDeviceDescr` ='network interface br0',`hrDeviceStatus` ='running',`hrDeviceErrors` ='0' WHERE device_id='5' AND hrDeviceIndex='262150'[0m]
- .SQL[[0;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = '5' AND hrDeviceIndex = '786432'[0m]
- SQL[[0;33mUPDATE `hrDevice` set `hrDeviceType` ='hrDeviceCoprocessor',`hrDeviceDescr` ='Guessing that there\\\'s a floating point co-processor',`hrDeviceStatus` ='',`hrDeviceErrors` ='' WHERE device_id='5' AND hrDeviceIndex='786432'[0m]
- .SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id` = '5'[0m]
- >> Runtime for discovery module 'hr-device': 1.0430 seconds with 9640 bytes
- >> SNMP: [2/0.13s] MySQL: [11/0.91s] RRD: [0/0.00s]
- #### Unload disco module hr-device ####
- Modules status: Global+ OS+ Device
- #### Load disco module discovery-protocols ####
- CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 cdpCache[0m]
- cdpCache = No Such Object available on this agent at this OID
- LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 lldpRemTable[0m]
- lldpRemTable = No Such Object available on this agent at this OID
- OSPF Discovery: SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='5'[0m]
- SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '5'[0m]
- SQL[[0;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL[0m]
- 0 orphaned links deleted
- >> Runtime for discovery module 'discovery-protocols': 0.1590 seconds with 4752 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module discovery-protocols ####
- Modules status: Global+ OS+ Device
- #### Load disco module arp-table ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
- ipNetToPhysicalPhysAddress[6][ipv4]["*"] = 64:d1:54:4f:bf:c7
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
- ipNetToMediaPhysAddress[6][*] = 64:d1:54:4f:bf:c7
- SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='5' AND `context_name`=''[0m]
- SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '5' AND `ifIndex` = '6'[0m]
- br0:
- 64:d1:54:4f:bf:c7 => 192.168.88.1
- SQL[[0;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL[0m]
- >> Runtime for discovery module 'arp-table': 0.1410 seconds with 17688 bytes
- >> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
- #### Unload disco module arp-table ####
- Modules status: Global- OS- Device Module [ discovery-arp ] disabled on os.
- Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
- Modules status: Global+ OS- Device Module [ bgp-peers ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module vlans ####
- SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '5'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
- dot1dBasePortIfIndex = No Such Object available on this agent at this OID
- IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
- No Such Object available on this agent at this OID
- >> Runtime for discovery module 'vlans': 0.0950 seconds with 6608 bytes
- >> SNMP: [2/0.09s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vlans ####
- Modules status: Global- OS+ Device
- #### Load disco module vmware-vminfo ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m +VMWARE-ROOT-MIB:VMWARE-VMINFO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell:/opt/librenms/mibs/vmware udp:HOSTNAME:161 vmwVmTable[0m]
- vmwVmTable = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT id, vmwVmVMID, vmwVmDisplayName FROM vminfo WHERE device_id = '5' AND vm_type='vmware'[0m]
- >> Runtime for discovery module 'vmware-vminfo': 0.3320 seconds with 3360 bytes
- >> SNMP: [1/0.33s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module vmware-vminfo ####
- Modules status: Global- OS+ Device
- #### Load disco module libvirt-vminfo ####
- SQL[[0;33mSELECT id, vmwVmVMID, vmwVmDisplayName FROM vminfo WHERE device_id = '5' AND vm_type='libvirt'[0m]
- >> Runtime for discovery module 'libvirt-vminfo': 0.0260 seconds with 3144 bytes
- >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module libvirt-vminfo ####
- Modules status: Global- OS- Device Module [ toner ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ucd-diskio ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 diskIOEntry[0m]
- diskIOEntry = No Such Object available on this agent at this OID
- Array
- (
- )
- SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id` = '5'[0m]
- >> Runtime for discovery module 'ucd-diskio': 0.0520 seconds with 3072 bytes
- >> SNMP: [1/0.05s] MySQL: [1/0.00s] RRD: [0/0.00s]
- #### Unload disco module ucd-diskio ####
- Modules status: Global- OS+ Device
- #### Load disco module applications ####
- Applications: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NET-SNMP-EXTEND-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 nsExtendStatus[0m]
- nsExtendStatus = No Such Object available on this agent at this OID
- Available:
- Checking for:
- SQL[[0;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`='5' ORDER BY `app_type`[0m]
- SQL[[0;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL[0m]
- >> Runtime for discovery module 'applications': 0.0500 seconds with 4728 bytes
- >> SNMP: [1/0.05s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module applications ####
- Modules status: Global+ OS+ Device
- #### Load disco module services ####
- >> Runtime for discovery module 'services': 0.0000 seconds with 288 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module services ####
- Modules status: Global+ OS- Device Module [ stp ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module ntp ####
- >> Runtime for discovery module 'ntp': 9.5120 seconds with 144 bytes
- >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
- #### Unload disco module ntp ####
- Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
- Modules status: Global- OS- Device Module [ mef ] disabled on os.
- Modules status: Global+ OS+ Device
- #### Load disco module wireless ####
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='ap-count'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='clients'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='quality'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='capacity'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='utilization'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='rate'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='ccq'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='snr'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='ssr'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='mse'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='rssi'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='power'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='noise-floor'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='errors'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='error-ratio'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='error-rate'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='frequency'[0m]
- SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='5' AND `sensor_class`='distance'[0m]
- >> Runtime for discovery module 'wireless': 0.0090 seconds with 185888 bytes
- >> SNMP: [0/0.00s] MySQL: [18/0.01s] RRD: [0/0.00s]
- #### Unload disco module wireless ####
- Modules status: Global+ OS+ Device
- #### Load disco module fdb-table ####
- SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '5'[0m]
- SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '5'[0m]
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1qTpFdbPort[0m]
- dot1qTpFdbPort = No Such Object available on this agent at this OID
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/supermicro:/opt/librenms/mibs/dell udp:HOSTNAME:161 dot1dTpFdbPort[0m]
- dot1dTpFdbPort = No Such Object available on this agent at this OID
- >> Runtime for discovery module 'fdb-table': 0.1030 seconds with 7168 bytes
- >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
- #### Unload disco module fdb-table ####
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '5' AND `attrib_type` = 'poll_mib' [0m]
- SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='5.985' WHERE `device_id` = '5'[0m]
- Discovered in 5.985 seconds
- SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','ata.bertie.nz','1522140898.2524','6.353','1','nms')[0m]
- ./discovery.php ata.bertie.nz 2018-03-27 21:55:04 - 1 devices discovered in 6.353 secs
- SNMP [56/3.17s]: Get[19/0.56s] Getnext[0/0.00s] Walk[37/2.61s]
- MySQL [120/1.45s]: Cell[24/0.01s] Row[5/0.00s] Rows[69/0.03s] Column[1/0.00s] Update[15/1.17s] Insert[2/0.23s] Delete[4/0.00s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]