  1. LibreNMS Discovery
  2. ===================================
  3. Version info:
  4. Commit SHA: 34ed39c1f9a0aa9c21fe4d0859c7f3ac3678a976
  5. Commit Date: 1514928991
  6. DB Schema: 227
  7. PHP: 5.6.30-0+deb8u1
  8. MySQL: 10.0.32-MariaDB-0+deb8u1
  9. RRDTool: 1.4.8
  10. SNMP: NET-SNMP 5.7.2.1
  11. ==================================DEBUG!
  12. SQL[SELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '10.0.10.4' ORDER BY device_id DESC]
  13. SQL[SELECT * FROM devices_attribs WHERE `device_id` = '35']
  14. 10.0.10.4 35 generex-ups SQL[INSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','3.80','5.93','4.53','35',NOW())]
  15. SNMP Check response code: 0
  16. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '35' AND `attrib_type` = 'poll_mib' ]
  17.  
  18. Modules status: Global+ OS+ Device  
  19. #### Load disco module os ####
  20. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0]
  21. CS121 v 5.40.59
  22.  
  23. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0]
  24. .*.2.1.33
  25.  
  26. | CS121 v 5.40.59 | .1.3.6.1.2.1.33 |
  27. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.4.1.12148.10.2.6.0]
  28.  
  29. OS: Generex UPS SNMP adapter (generex-ups)
  30.  
  31. >> Runtime for discovery module 'os': 0.0360 seconds with 2504 bytes
  32. >> SNMP: [4/0.05s] MySQL: [8/0.00s] RRD: [0/0.00s]
  33. #### Unload disco module os ####
  34.  
  35. Modules status: Global+ OS+ Device  
  36. #### Load disco module ports ####
  37. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr]
  38. ifDescr.1 = CS121 Ethernet
  39.  
  40. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName]
  41.  
  42. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias]
  43.  
  44. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType]
  45. ifType.1 = ethernetCsmacd
  46.  
  47. Array
  48. (
  49.     [1] => Array
  50.         (
  51.             [ifDescr] => CS121 Ethernet
  52.             [ifType] => ethernetCsmacd
  53.         )
  54.  
  55. )
  56. SQL[SELECT `name` FROM `port_association_mode` WHERE pom_id = '1']
  57. SQL[SELECT * FROM `ports` WHERE `device_id` = '35' ORDER BY port_id]
  58. .
  59.  
  60. >> Runtime for discovery module 'ports': 1.6940 seconds with 5704 bytes
  61. >> SNMP: [4/1.69s] MySQL: [2/0.00s] RRD: [0/0.00s]
  62. #### Unload disco module ports ####
  63.  
  64. Modules status: Global+ OS- Device  Module [ ports-stack ] disabled on os.
  65.  
  66. Modules status: Global+ OS- Device  Module [ entity-physical ] disabled on os.
  67.  
  68. Modules status: Global- OS- Device  Module [ entity-state ] disabled on os.
  69.  
  70. Modules status: Global+ OS- Device  Module [ processors ] disabled on os.
  71.  
  72. Modules status: Global+ OS- Device  Module [ mempools ] disabled on os.
  73.  
  74. Modules status: Global+ OS+ Device  
  75. #### Load disco module cisco-vrf-lite ####
  76. SQL[SELECT * FROM vrf_lite_cisco WHERE device_id = '35' ]
  77.  
  78. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2456 bytes
  79. >> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
  80. #### Unload disco module cisco-vrf-lite ####
  81.  
  82. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  83.  
  84. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  85.  
  86. Modules status: Global- OS- Device  Module [ cisco-vrf ] disabled on os.
  87.  
  88. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  89.  
  90. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  91.  
  92. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  93.  
  94. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  95.  
  96. Modules status: Global+ OS+ Device  
  97. #### Load disco module ipv4-addresses ####
  98. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex]
  99. ipAdEntIfIndex.* 1
  100.  
  101. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.10.0.10.4]
  102.  
  103. SQL[SELECT COUNT(*) FROM `ports` WHERE device_id = '35' AND `ifIndex` = '1']
  104. SQL[SELECT `port_id` FROM `ports` WHERE `device_id` = '35' AND `ifIndex` = '1']
  105. SQL[SELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.10.4/0']
  106. SQL[UPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '10.0.10.4/0']
  107. sSQL[SELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '10.0.10.4/0']
  108. SQL[SELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '10.0.10.4' AND `ipv4_prefixlen` = '0' AND `port_id` = '2543' ]
  109. SQL[UPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '10.0.10.4' AND `ipv4_prefixlen` = '0' AND `port_id` = '2543']
  110. .SQL[SELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '35' OR `ports`.`device_id` IS NULL]
  111.  
  112.  
  113. >> Runtime for discovery module 'ipv4-addresses': 0.0460 seconds with 59024 bytes
  114. >> SNMP: [2/0.04s] MySQL: [8/0.01s] RRD: [0/0.00s]
  115. #### Unload disco module ipv4-addresses ####
  116.  
  117. Modules status: Global+ OS+ Device  
  118. #### Load disco module ipv6-addresses ####
  119. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6]
  120.  
  121. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength]
  122. .*.*.8.1.2 No more variables left in this MIB View (It is past the end of the MIB tree)
  123.  
  124. SQL[SELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '35' OR `ports`.`device_id` IS NULL]
  125.  
  126.  
  127. >> Runtime for discovery module 'ipv6-addresses': 0.0350 seconds with 3192 bytes
  128. >> SNMP: [2/0.03s] MySQL: [1/0.00s] RRD: [0/0.00s]
  129. #### Unload disco module ipv6-addresses ####
  130.  
  131. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  132.  
  133. Modules status: Global+ OS+ Device  
  134. #### Load disco module sensors ####
  135.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr]
  136. entPhysicalDescr = No more variables left in this MIB View (It is past the end of the MIB tree)
  137.  
  138.  
  139. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '35' AND `attrib_type` = 'ipmi_hostname' ]
  140. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'ipmi']
  141. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'ipmi']
  142. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'ipmi']
  143. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'ipmi']
  144. Airflow: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  145.  
  146. Current: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OqvU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryCurrent.0]
  147. 0
  148.  
  149. Discover sensor: .1.3.6.1.2.1.33.1.2.6.0, 500, rfc1628, Battery, snmp, 10, 1, , 0
  150. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '35' AND sensor_type = 'rfc1628' AND `sensor_index` = '500']
  151. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '35' AND `sensor_type` = 'rfc1628' AND `sensor_index` = '500']
  152. .SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputCurrent]
  153. upsOutputCurrent[1] = 0
  154.  
  155. Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.3.1, 1, rfc1628, Output, snmp, 10, 1, , 0
  156. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '35' AND sensor_type = 'rfc1628' AND `sensor_index` = '1']
  157. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '35' AND `sensor_type` = 'rfc1628' AND `sensor_index` = '1']
  158. .SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputCurrent]
  159.  
  160. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBypassCurrent]
  161.  
  162. Array
  163. (
  164.     [rfc1628] => Array
  165.         (
  166.             [500] => 1
  167.             [1] => 1
  168.         )
  169.  
  170. )
  171. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  172. 500 -> rfc1628
  173. 1 -> rfc1628
  174.  
  175. Charge: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OvqU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsEstimatedChargeRemaining.0]
  176.  
  177. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  178.  
  179. Dbm: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  180.  
  181. Fanspeed: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  182.  
  183. Frequency: RFC1628 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputFrequency]
  184.  
  185. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OqvU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputFrequency.0]
  186.  
  187. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OqvU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBypassFrequency.0]
  188.  
  189. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  190.  
  191. Humidity: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  192.  
  193. Load: RFC1628 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputPercentLoad]
  194.  
  195. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  196.  
  197. Power: RFC1628 SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputPower]
  198.  
  199. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputTruePower]
  200.  
  201. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBypassPower]
  202.  
  203. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  204.  
  205. Runtime: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.33.1.2.2.0]
  206.  
  207. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 .1.3.6.1.2.1.33.1.2.3.0]
  208.  
  209. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  210.  
  211. Signal: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  212.  
  213. State: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryStatus.0]
  214.  
  215. SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputSource.0]
  216.  
  217. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  218.  
  219. Temperature: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OqvU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryTemperature.0]
  220.  
  221. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  222.  
  223. Voltage: RFC1628 SNMP[/usr/bin/snmpget -v2c -c COMMUNITY -OqvU -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryVoltage.0]
  224. 820
  225.  
  226. Discover sensor: .1.3.6.1.2.1.33.1.2.5.0, 1.2.5.0, rfc1628, Battery, snmp, 10, 1, , 82
  227. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '35' AND sensor_type = 'rfc1628' AND `sensor_index` = '1.2.5.0']
  228. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '35' AND `sensor_type` = 'rfc1628' AND `sensor_index` = '1.2.5.0']
  229. .SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputVoltage]
  230. upsOutputVoltage[1] = 230
  231.  
  232. Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.2.1, 1, rfc1628, Output, snmp, 1, 1, , 230
  233. SQL[SELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '35' AND sensor_type = 'rfc1628' AND `sensor_index` = '1']
  234. SQL[SELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '35' AND `sensor_type` = 'rfc1628' AND `sensor_index` = '1']
  235. .SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputVoltage]
  236.  
  237. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBypassVoltage]
  238.  
  239. Array
  240. (
  241.     [rfc1628] => Array
  242.         (
  243.             [1.2.5.0] => 1
  244.             [1] => 1
  245.         )
  246.  
  247. )
  248. SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  249. 1.2.5.0 -> rfc1628
  250. 1 -> rfc1628
  251.  
  252. Snr: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  253.  
  254. Pressure: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  255.  
  256. Cooling: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  257.  
  258. Delay: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='delay' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  259.  
  260. Quality_factor: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='quality_factor' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  261.  
  262. Chromatic_dispersion: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='chromatic_dispersion' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  263.  
  264. Ber: SQL[SELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='ber' AND S.device_id = D.device_id AND D.device_id = '35' AND S.poller_type = 'snmp']
  265.  
  266.  
  267. >> Runtime for discovery module 'sensors': 112.5000 seconds with 13448 bytes
  268. >> SNMP: [11/52.19s] MySQL: [34/0.02s] RRD: [0/0.00s]
  269. #### Unload disco module sensors ####
  270.  
  271. Modules status: Global+ OS- Device  Module [ storage ] disabled on os.
  272.  
  273. Modules status: Global+ OS- Device  Module [ hr-device ] disabled on os.
  274.  
  275. Modules status: Global+ OS- Device  Module [ discovery-protocols ] disabled on os.
  276.  
  277. Modules status: Global+ OS- Device  Module [ arp-table ] disabled on os.
  278.  
  279. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  280.  
  281. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  282.  
  283. Modules status: Global+ OS- Device  Module [ bgp-peers ] disabled on os.
  284.  
  285. Modules status: Global+ OS- Device  Module [ vlans ] disabled on os.
  286.  
  287. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  288.  
  289. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  290.  
  291. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  292.  
  293. Modules status: Global+ OS- Device  Module [ ucd-diskio ] disabled on os.
  294.  
  295. Modules status: Global- OS- Device  Module [ applications ] disabled on os.
  296.  
  297. Modules status: Global+ OS+ Device  
  298. #### Load disco module services ####
  299.  
  300. >> Runtime for discovery module 'services': 0.0000 seconds with 392 bytes
  301. >> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
  302. #### Unload disco module services ####
  303.  
  304. Modules status: Global+ OS- Device  Module [ stp ] disabled on os.
  305.  
  306. Modules status: Global+ OS- Device  Module [ ntp ] disabled on os.
  307.  
  308. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  309.  
  310. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  311.  
  312. Modules status: Global+ OS+ Device  
  313. #### Load disco module wireless ####
  314. Attempting to initialize OS: generex-ups
  315. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='ap-count']
  316. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='clients']
  317. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='quality']
  318. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='capacity']
  319. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='utilization']
  320. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='rate']
  321. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='ccq']
  322. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='snr']
  323. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='ssr']
  324. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='mse']
  325. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='rssi']
  326. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='power']
  327. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='noise-floor']
  328. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='error-ratio']
  329. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='error-rate']
  330. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='frequency']
  331. SQL[SELECT * FROM `wireless_sensors` WHERE `device_id`='35' AND `sensor_class`='distance']
  332.  
  333. >> Runtime for discovery module 'wireless': 0.0080 seconds with 211272 bytes
  334. >> SNMP: [0/0.00s] MySQL: [17/0.00s] RRD: [0/0.00s]
  335. #### Unload disco module wireless ####
  336.  
  337. Modules status: Global+ OS+ Device  
  338. #### Load disco module fdb-table ####
  339. SQL[SELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '35']
  340. SQL[SELECT * FROM `ports_fdb` WHERE `device_id` = '35']
  341. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qTpFdbPort]
  342.  
  343. SNMP[/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dTpFdbPort]
  344.  
  345.  
  346.  
  347. >> Runtime for discovery module 'fdb-table': 12.0300 seconds with 2904 bytes
  348. >> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
  349. #### Unload disco module fdb-table ####
  350.  
  351. SQL[SELECT attrib_value FROM devices_attribs WHERE `device_id` = '35' AND `attrib_type` = 'poll_mib' ]
  352. SQL[UPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='127.467' WHERE `device_id` = '35']
  353. Discovered in 127.467 seconds
  354.  
  355. SQL[INSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','10.0.10.4','1514975373.2275','127.4','1','NMS')]
  356. /opt/librenms/discovery.php 10.0.10.4 2018-01-03 11:31:40 - 1 devices discovered in 127.4 secs
  357. SNMP [23/54.00s]: Get[15/52.23s] Getnext[0/0.00s] Walk[8/1.76s]
  358. MySQL [76/0.04s]: Cell[12/0.00s] Row[7/0.00s] Rows[52/0.02s] Column[0/0.00s] Update[3/0.01s] Insert[2/0.00s] Delete[0/0.00s]
  359. RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]