-- SOCOMEC MIB
-- UPS MIB for SOCOMEC UPS - Uninterruptible Power Supplies
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555)
-- software(1) network(1) netvision(7) }
-- ==============================================================================================

-- vers. 7.00: new version for Net Vision 7 platform by NVO.
-- vers. 7.10: release.
-- vers. 7.11: OutputGlobalkW

SOCOMECUPS-MIB DEFINITIONS ::= BEGIN

IMPORTS
  DisplayString, TimeStamp, TimeInterval, TestAndIncr,
  AutonomousType
    FROM SNMPv2-TC
  enterprises
    FROM RFC1155-SMI
  OBJECT-TYPE
    FROM RFC-1212
  DisplayString
    FROM RFC1213-MIB
  TRAP-TYPE
    FROM RFC-1215;

PositiveInteger ::= INTEGER (1..2147483647)
NonNegativeInteger ::= INTEGER (1..2147483647)


socomec          OBJECT IDENTIFIER ::= { enterprises 4555 }
software         OBJECT IDENTIFIER ::= { socomec 1 }
network          OBJECT IDENTIFIER ::= { software 1 }
netvision7       OBJECT IDENTIFIER ::= { network 7 }
upsObjects       OBJECT IDENTIFIER ::= { netvision7 1 }
upsTraps         OBJECT IDENTIFIER ::= { netvision7 2 }


upsIdent         OBJECT IDENTIFIER ::= { upsObjects 1 }
upsBattery       OBJECT IDENTIFIER ::= { upsObjects 2 }
upsInput         OBJECT IDENTIFIER ::= { upsObjects 3 }
upsOutput        OBJECT IDENTIFIER ::= { upsObjects 4 }
upsBypass        OBJECT IDENTIFIER ::= { upsObjects 5 }
upsAlarm         OBJECT IDENTIFIER ::= { upsObjects 6 }
upsControl       OBJECT IDENTIFIER ::= { upsObjects 7 }
upsConfig        OBJECT IDENTIFIER ::= { upsObjects 8 }
upsAgent         OBJECT IDENTIFIER ::= { upsObjects 9 }
emdStatus        OBJECT IDENTIFIER ::= { upsObjects 10 }


-- ===========================================================================
--
-- upsIdentification
--
--     All objects in this group except for upsIdentUserRef and
--     upsIdentUserLocation are set at device initialization
--     and remain static.
--
-- ===========================================================================

upsIdentModel OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..31))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Model designation."
      ::= { upsIdent 1 }

upsIdentSerialNumber OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..19))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Serial number."
      ::= { upsIdent 2 }

upsIdentUserRef OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..11))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Reference."
      ::= { upsIdent 3 }

upsIdentUserLocation OBJECT-TYPE
      SYNTAX DisplayString (SIZE (0..11))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Location."
      ::= { upsIdent 4 }

upsIdentAgentSoftwareVersion OBJECT-TYPE
      SYNTAX DisplayString (SIZE(0..31))
      ACCESS read-only
      STATUS mandatory
      DESCRIPTION
          "The UPS Net Vision software version."
      ::= { upsIdent 5 }

-- ===========================================================================
-- upsBattery
--
--     The Battery group.
-- ===========================================================================

upsBatteryStatus OBJECT-TYPE
     SYNTAX     INTEGER {
           unknown(1),
           batteryNormal(2),
           batteryCharging(3),
           batteryTest(4),
           batteryDischarging(5),
           batteryLow(6),
           batteryDepleted(7),
           batteryFailure(8),
           batteryDisconnected(9)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present battery status"
     ::= { upsBattery 1 }

upsSecondsOnBattery OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
        "If the unit is on battery power, the elapsed time
        since the UPS last switched to battery power, or the
        time since the network management subsystem was last
        restarted, whichever is less.  -1 shall be returned
        if the unit is not on battery power."
     ::= { upsBattery 2 }

upsEstimatedMinutesRemaining OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
        "An estimate of the time to battery charge depletion
        under the present load conditions. Compute when UPS is 
        on battery power"
     ::= { upsBattery 3 }

upsEstimatedChargeRemaining OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
        "An estimate of the battery charge remaining expressed
         as a percent of full charge."
     ::= { upsBattery 4 }

upsBatteryVoltage OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The magnitude of the present battery voltage in 0.1 Volt DC."
     ::= { upsBattery 5 }

upsBatteryTemperature OBJECT-TYPE
    SYNTAX     INTEGER    
    ACCESS read-only
    STATUS     mandatory
    DESCRIPTION
            "The ambient temperature at or near the UPS Battery casing in 0.1 degree"
    ::= { upsBattery 6 }

-- vers. 7.10


upsAmbientTemperature OBJECT-TYPE
    SYNTAX     INTEGER    
    ACCESS read-only
    STATUS     mandatory
    DESCRIPTION
            "The ambient temperature inside the UPS in 0.1 degree"
    ::= { upsBattery 7 }

-- vers. 7.10

upsBatteryCurrent OBJECT-TYPE
    SYNTAX     INTEGER    
    ACCESS read-only
    STATUS     mandatory
    DESCRIPTION
            "The battry current in 0.1 Amp"
    ::= { upsBattery 8 }

-- ===========================================================================
-- upsInput
--
-- Input group.
-- ===========================================================================

upsInputNumLines OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The number of input lines utilized in this device.
          This variable indicates the number of rows in the
          input table."
     ::= { upsInput 1 }

upsInputFrequency OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The current input frequency to the UPS system in 0.1 HZ."
     ::= { upsInput 2 }


upsInputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsInputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A list of input table entries.  The number of entries
         is given by the value of upsInputNumLines."
    ::= { upsInput  3 }

upsInputEntry OBJECT-TYPE
    SYNTAX  UpsInputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "An entry containing information applicable to a
         particular input line."
    INDEX { upsInputLineIndex }
    ::= { upsInputTable  1 }

UpsInputEntry ::= SEQUENCE {
             upsInputLineIndex INTEGER,
             upsInputVoltage INTEGER,
             upsInputCurrent INTEGER,
             upsInputVoltageMax INTEGER,
             upsInputVoltageMin INTEGER
             }

upsInputLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..65535)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         ""
     ::= { upsInputEntry 1 }

upsInputVoltage OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The input utility line voltage in 0.1 volts."
     ::= { upsInputEntry 2 }

upsInputCurrent OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The magnitude of the present input current in 0.1 A."
     ::= { upsInputEntry 3 }

upsInputVoltageMax OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The maximum utility line voltage in 0.1 VAC for last 1 minute."
     ::= { upsInputEntry 4 }

upsInputVoltageMin OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The minimum utility line voltage in 0.1 VAC for last 1 minute."
     ::= { upsInputEntry 5 }

-- ===========================================================================
-- upsOutput
--
-- Output group
-- ===========================================================================

upsOutputSource OBJECT-TYPE
     SYNTAX     INTEGER {
           unknown(1),
           onMaintenBypass(2),
           onInverter(3),
           normalMode(4),
           ecoMode(5),
           onBypass(6),
           standby(7),
           upsOff(8)
     }
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present source of output power."
     ::= { upsOutput 1 }

upsOutputFrequency OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The current output frequency of the UPS system in 0.1 of HZ."
     ::= { upsOutput 2 }

upsOutputNumLines OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The number of output lines utilized in this device.
          This variable indicates the number of rows in the
          output table."
     ::= { upsOutput 3 }

upsOutputTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsOutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A list of output table entries.  The number of
         entries is given by the value of upsOutputNumLines."
    ::= { upsOutput  4 }

upsOutputEntry OBJECT-TYPE
    SYNTAX  UpsOutputEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "An entry containing information applicable to a
         particular output line."
    INDEX { upsOutputLineIndex }
    ::= { upsOutputTable  1 }

UpsOutputEntry ::=
    SEQUENCE {
             upsOutputLineIndex          INTEGER,
             upsOutputVoltage            INTEGER,
             upsOutputCurrent            INTEGER,
             upsOutputPercentLoad        INTEGER,
             upsOutputKva                INTEGER,
             upsOutputKw                 INTEGER
             }

upsOutputLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..65535)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The output line identifier."
     ::= { upsOutputEntry 1 }

upsOutputVoltage OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The output voltage of the UPS system in 0.1 volts."
     ::= { upsOutputEntry 2 }

upsOutputCurrent OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The output current of the UPS system in 0.1 Amps."
     ::= { upsOutputEntry 3 }

upsOutputPercentLoad OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The percentage of the UPS power capacity presently
             being used on this output line"
     ::= { upsOutputEntry 4 }

upsOutputKva OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Output apparent power of the UPS in 0.1 kVA."
     ::= { upsOutputEntry 5 }

upsOutputKw OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Output apparent power of the UPS in 0.1 kW."
     ::= { upsOutputEntry 6 }

-- vers. 7.10

upsOutputGlobalkVA OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Output global apparent power of the UPS in 0.1 kVA."
     ::= { upsOutput 5 }

-- vers. 7.11

upsOutputGlobalkW OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Output global apparent power of the UPS in 0.1 kW."
     ::= { upsOutput 6 }

-- vers. 7.10

upsOutputLoadRate OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Output global Load Rate."
     ::= { upsOutput 7 }
     
-- ===========================================================================
-- upsBypass
-- ===========================================================================

upsBypassFrequency OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present bypass frequency in 0.1 Hz."
     ::= { upsBypass 1 }

upsBypassNumLines OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The number of bypass lines utilized in this device.
             This entry indicates the number of rows in the bypass
             table."
     ::= { upsBypass 2 }

upsBypassTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsBypassEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
        "A list of bypass table entries.  The number of
         entries is given by the value of upsBypassNumLines."
    ::= { upsBypass  3 }

upsBypassEntry OBJECT-TYPE
    SYNTAX  UpsBypassEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "An entry containing information applicable to a
               particular bypass input."
    INDEX { upsBypassLineIndex }
    ::= { upsBypassTable  1 }

UpsBypassEntry ::=
    SEQUENCE {
             upsBypassLineIndex          INTEGER,
             upsBypassVoltage            INTEGER,
             upsBypassCurrent            INTEGER
             }

upsBypassLineIndex OBJECT-TYPE
     SYNTAX INTEGER (0..65535)
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The bypass line identifier."
     ::= { upsBypassEntry 1 }

upsBypassVoltage OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present bypass voltage of the UPS system in 0.1 volts."
     ::= { upsBypassEntry 2 }

upsBypassCurrent OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present bypass current of the UPS system in 0.1 Amps."
     ::= { upsBypassEntry 3 }

-- ===========================================================================
-- upsAlarm

-- See Section 4 for Status/Alarm details for all variables
-- ===========================================================================

upsAlarmsPresent OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The present number of active alarm conditions."
     ::= { upsAlarm 1 }

upsAlarmTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF UpsAlarmEntry
    ACCESS  not-accessible
    STATUS  mandatory
    DESCRIPTION
           "A list of alarm table entries.  The table contains
               zero, one, or many rows at any moment, depending upon
               the number of alarm conditions in effect.  The table
               is initially empty at agent startup.  The agent
               creates a row in the table each time a condition is
               detected and deletes that row when that condition no
               longer pertains.  The agent creates the first row with
               upsAlarmId equal to 1, and increments the value of
               upsAlarmId each time a new row is created, wrapping to
               the first free value greater than or equal to 1 when
               the maximum value of upsAlarmId would otherwise be
               exceeded.  Consequently, after multiple operations,
               the table may become sparse, e.g., containing entries
               for rows 95, 100, 101, and 203 and the entries should
               not be assumed to be in chronological order because
               upsAlarmId might have wrapped.

               Alarms are named by an OBJECT IDENTIFIER,
               upsAlarmDescr, to allow a single table to
               reflect well known alarms plus alarms defined by a
               particular implementation, i.e., as documented in the
               private enterprise MIB definition for the device.  No
               two rows will have the same value of upsAlarmDescr,
               since alarms define conditions.  In order to meet this
               requirement, care should be taken in the definition of
               alarm conditions to insure that a system cannot enter
               the same condition multiple times simultaneously.

               The number of rows in the table at any given time is
               reflected by the value of upsAlarmsPresent."
    ::= { upsAlarm  2 }

upsAlarmEntry OBJECT-TYPE
    SYNTAX      UpsAlarmEntry
    ACCESS      not-accessible
    STATUS      mandatory
    DESCRIPTION
        "An entry containing information applicable to a
         particular alarm."
    INDEX { upsAlarmId }
    ::= { upsAlarmTable  1 }

UpsAlarmEntry ::=
    SEQUENCE {
             upsAlarmId          PositiveInteger,
             upsAlarmDescr       AutonomousType,
             upsAlarmTime        TimeStamp,
             upsAlarmExtDes      DisplayString
             }

-- ===========================================================================
--  Agent item
-- upsAlarmTable/upsAlarmEntry/upsAlarmId
-- ===========================================================================

   upsAlarmId OBJECT-TYPE
       SYNTAX     PositiveInteger
       ACCESS     read-only
       STATUS     mandatory
       DESCRIPTION
               "A unique identifier for an alarm condition.  This
               value must remain constant."
       ::= { upsAlarmEntry 1 }

   upsAlarmDescr OBJECT-TYPE
       SYNTAX     AutonomousType
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "A reference to an alarm description object.  The
               object referenced should not be accessible, but rather
               be used to provide a unique description of the alarm
               condition."
       ::= { upsAlarmEntry 2 }

   upsAlarmTime OBJECT-TYPE
       SYNTAX     TimeStamp
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "The value of sysUpTime when the alarm condition was
               detected.  If the alarm condition was detected at the
               time of agent startup and presumably existed before
               agent startup, the value of upsAlarmTime shall equal
               0."
       ::= { upsAlarmEntry 3 }

   upsAlarmExtDes OBJECT-TYPE
       SYNTAX     DisplayString
       ACCESS read-only
       STATUS     mandatory
       DESCRIPTION
               "Extra description."
       ::= { upsAlarmEntry 4 }

upsWellKnownAlarms OBJECT IDENTIFIER ::= { upsAlarm  3 }

upsAlarmImminentStop OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "UPS in imminent stop. Load will switch off. (A000)"
     ::= { upsWellKnownAlarms 1 }

upsAlarmOverload OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The output load exceeds the UPS output capacity. (A001)"
     ::= { upsWellKnownAlarms 2 }

upsAlarmTemperature OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "UPS temperature is out of tolerance. (A002)"
     ::= { upsWellKnownAlarms 3 }

upsAlarmTransferLock OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Automatic and manual transfer are locked. (A003)"
     ::= { upsWellKnownAlarms 4 }

upsAlarmAutoTransferImpossible OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Automatic transfer is disabled. 
         Inverter and bypass sources are not synchronized (A004)"
     ::= { upsWellKnownAlarms 5 }

     upsAlarmInsufficientResources OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Insufficient resources alarm. 
         The load cannot by supplied by alternate source (A005)"
     ::= { upsWellKnownAlarms 6 }

upsAlarmRedundancyLost OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Redundancy lost alarm. (A006)"
     ::= { upsWellKnownAlarms 7 }

upsAlarmOutputShortCircuit OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "An output short-circuit has been detected by UPS. (A007)"
     ::= { upsWellKnownAlarms 8 }

upsAlarmMaintenance OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS requests a maintenance service check. (A012)"
     ::= { upsWellKnownAlarms 9 }

upsAlarmRemoteService OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS requests a remote service action. (A013)"
     ::= { upsWellKnownAlarms 10 }

upsAlarmGeneralFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "A general fault in the UPS has been detected.
         One of UPS alarm is present. (A015)"
     ::= { upsWellKnownAlarms 11 }

upsAlarmBatteryCircuitOpen OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Battery circuit open. Battery breaker or fuse open. (A016)"
     ::= { upsWellKnownAlarms 12 }

upsAlarmBatteryDischarged OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS will be unable to sustain the present load
          when and if the utility power is lost. 
          The Battery is discharched. (A017)"
     ::= { upsWellKnownAlarms 13 }

upsAlarmLowBattery OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The remaining battery run-time is less than or equal
         to battery low threshold. (A018)"
     ::= { upsWellKnownAlarms 14 }

upsAlarmOnBattery OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS is drawing power from the batteries. (A019)"
     ::= { upsWellKnownAlarms 15 }

upsAlarmBatteryTemperature OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Battery Temperature Alarm. (A020)"
     ::= { upsWellKnownAlarms 16 }

upsAlarmBatteryRoom OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "An external alarm has been detected in the Battery room.
         This alarm depends on external sensor: gaz, temperature, 
         humidity or dry-contact. (A021)"
     ::= { upsWellKnownAlarms 17 }

upsAlarmBatteryTest OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The battery has been detected as weak during the test. (A022)"
     ::= { upsWellKnownAlarms 18 }

upsAlarmBatteryFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "One or more batteries have been determined to require replacement. (A027)"
     ::= { upsWellKnownAlarms 19 }

upsAlarmRectifierFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Rectifier Critical alarm. (A032)"
     ::= { upsWellKnownAlarms 20 }

upsAlarmRectifierAlarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Rectifier Preventive alarm. (A033)"
     ::= { upsWellKnownAlarms 21 }

upsAlarmRecInputBad OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "rectifier Input power supply is out of tolerance or absent. (A035)"
     ::= { upsWellKnownAlarms 22 }

upsAlarmGenSetGeneral OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Gen-set general alarm.
         coming from external dry-contact. (A036)"
     ::= { upsWellKnownAlarms 23 }

upsAlarmBatteryChargerFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Battery charger Critical Alarm. (A037)"
     ::= { upsWellKnownAlarms 24 }

upsAlarmBatteryChargerAlarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Battery charger Preventive Alarm. (A038)"
     ::= { upsWellKnownAlarms 25 }

upsAlarmInverterFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Inverter Critical alarm. (A040)"
     ::= { upsWellKnownAlarms 26 }

upsAlarmInverterAlarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Inverter preventive alarm. (A041)"
     ::= { upsWellKnownAlarms 27 }

upsAlarmBypassFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Inverter Critical alarm. (A048)"
     ::= { upsWellKnownAlarms 28 }

upsAlarmBypassAlarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Inverter preventive alarm. (A049)"
     ::= { upsWellKnownAlarms 29 }

upsAlarmBypInputBad OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Bypass Input power supply is out of tolerance or absent. (A050)"
     ::= { upsWellKnownAlarms 30 }

upsAlarmPhaseRotationFault OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Phase rotation fault. (A051)"
     ::= { upsWellKnownAlarms 31 }

upsAlarmFansFailure OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Fans failure. (A054)"
     ::= { upsWellKnownAlarms 32 }

upsAlarmMaintenanceBypass OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Maintenance bypass alarm. 
         Output breaker and manual bypass breaker closed together. (A056)"
     ::= { upsWellKnownAlarms 33 }

upsAlarmUPSPowerOffActive OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "UPS power off has been activated by external device. (A059)"
     ::= { upsWellKnownAlarms 34 }

upsAlarmWrongConfiguration OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Configuration data map corrupted, or wrong configuration. (A060)"
     ::= { upsWellKnownAlarms 35 }

upsAlarmInternalFailure OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Internal failure, or internal communication failure. (A061)"
     ::= { upsWellKnownAlarms 36 }

upsAlarmOptionalBoards OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Optional boards alarm. 
         Board not present or wrong configuration (A062)"
     ::= { upsWellKnownAlarms 37 }

upsAlarmExternalAlarm1 OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "External Alarm 1. 
         Coming from ADC Card: Input set as alarm (A064)"
     ::= { upsWellKnownAlarms 38 }

upsAlarmExternalAlarm2 OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "External Alarm 2. 
         Coming from ADC Card: Input set as alarm (A065)"
     ::= { upsWellKnownAlarms 39 }

upsAlarmExternalAlarm3 OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "External Alarm 3. 
         Coming from ADC Card: Input set as alarm (A066)"
     ::= { upsWellKnownAlarms 40 }

upsAlarmExternalAlarm4 OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "External Alarm 4.
         Coming from ADC Card: Input set as alarm (A067)"
     ::= { upsWellKnownAlarms 41 }

upsAlarmModule1Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 1 in parallel general alarm."
     ::= { upsWellKnownAlarms 42 }

upsAlarmModule2Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 2 in parallel general alarm."
     ::= { upsWellKnownAlarms 43 }

upsAlarmModule3Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 3 in parallel general alarm."
     ::= { upsWellKnownAlarms 44 }

upsAlarmModule4Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 4 in parallel general alarm."
     ::= { upsWellKnownAlarms 45 }

upsAlarmModule5Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 5 in parallel general alarm."
     ::= { upsWellKnownAlarms 46 }

upsAlarmModule6Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 6 in parallel general alarm."
     ::= { upsWellKnownAlarms 47 }

upsAlarmModule7Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 7 in parallel general alarm."
     ::= { upsWellKnownAlarms 48 }

upsAlarmModule8Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 8 in parallel general alarm."
     ::= { upsWellKnownAlarms 49 }

upsAlarmModule9Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 9 in parallel general alarm."
     ::= { upsWellKnownAlarms 50 }

upsAlarmModule10Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 10 in parallel general alarm."
     ::= { upsWellKnownAlarms 51 }

upsAlarmModule11Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 11 in parallel general alarm."
     ::= { upsWellKnownAlarms 52 }

upsAlarmModule12Alarm OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Unit or Module 12 in parallel general alarm."
     ::= { upsWellKnownAlarms 53 }

upsAlarmAutoTestRunning OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS has launched the auto-test. (S030)"
     ::= { upsWellKnownAlarms 54 }

upsAlarmOnBypass OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Load supplied by automatic bypass.
         Load not protected."
     ::= { upsWellKnownAlarms 55 }

upsAlarmUpsOutputOff OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The output of the UPS is in the off state. 
         Load OFF or UPS on standby mode."
     ::= { upsWellKnownAlarms 56 }

upsAlarmUpsSystemOff OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS system is in the off state. 
         Rectifier and Inverter are off."
     ::= { upsWellKnownAlarms 57 }

upsAlarmCommunicationLost OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The communication with UPS has been lost."
     ::= { upsWellKnownAlarms 58 }

upsAlarmShutdownPending OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The condition to shutdown servers has been detected. 
         The shutdown delay in underway."
     ::= { upsWellKnownAlarms 59 }

upsAlarmShutdownRequestt OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The shutdown command has been sent to servers agent."
     ::= { upsWellKnownAlarms 60 }

upsAlarmShutdownImminent OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS will turn OFF,
         according the standby schedule settings."
     ::= { upsWellKnownAlarms 61 }

upsAlarmAwaitingPower OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "The UPS output is in standby,
         and the UPS is awaiting the return of input power."
     ::= { upsWellKnownAlarms 62 }


-- ===========================================================================
-- upsControl
--
-- ===========================================================================

upsControlStatusControl OBJECT-TYPE
     SYNTAX INTEGER {
            upsStandbyOn (1),
            upsStandbyOff (2),
            upsEcoMode (3),
            upsNormalMode (4),
            upsAlarmReset (5),
            upsOnBypass (6),
            upsOnInverter (7)
     }
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION
         "This object Control UPS status"
     ::= { upsControl 1 }

upsShutdownDelay OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION
         "This object set the delay time (in seconds) to turn UPS off after
          Net Vision broadcast shutdown request to connected clients"
     ::= { upsControl 2 }

upsTurnOffAfterShutdown OBJECT-TYPE
     SYNTAX INTEGER {
            enable (1),
            disable (2)
     }
     ACCESS read-write
     STATUS mandatory
     DESCRIPTION
         "This object enable/disable UPS turn off function after shutdown
          process complete"
     ::= { upsControl 3 }

upsControlShutdownParamTable OBJECT-TYPE
        SYNTAX SEQUENCE OF ShutdownParamEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "Table which describes the parameters for shutdown process
                 when shutdown event occurs"
                ::= { upsControl 4 }

shutdownParamEntry OBJECT-TYPE
        SYNTAX ShutdownParamEntry
        ACCESS not-accessible
        STATUS mandatory
        INDEX { upsControlEventIndex }
                ::= { upsControlShutdownParamTable 1 }

ShutdownParamEntry  ::= SEQUENCE {                
                upsControlEventIndex        
                    INTEGER,
                upsControlEventStatus       
                    INTEGER,
                upsControlDelay             
                    INTEGER,
                upsControlFirstWarning      
                    INTEGER,
                upsControlWarningInterval
                    INTEGER
                }

upsControlEventIndex OBJECT-TYPE
        SYNTAX INTEGER (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                " The shutdown event identification "
                ::= { shutdownParamEntry 1 }

upsControlEventStatus OBJECT-TYPE
        SYNTAX INTEGER {
            disable(1),
            warning(2),
            clientShutdown(3)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Status of the corresponding shutdown Event.
                 When set to disable(), shutdown process will not start when
                 corresponding event occurred."
                 ::= { shutdownParamEntry 2 }

upsControlDelay OBJECT-TYPE
        SYNTAX INTEGER (0..32767)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The Delay after the occurrence of the corresponding shutdown
                 event that Net Vision should issue shutdown request to
                 connected clients. For WeeklyScheduledShutdown and
                 SpecialScheduledShutdown, this is the time before the
                 configured Shutdown time when Net Vision will start sending the
                 warning message to the connected clients. The value is in
                 units of minutes."
                 ::= { shutdownParamEntry 3 }

upsControlFirstWarning OBJECT-TYPE
        SYNTAX INTEGER (0..32767)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The delay after the occurrence of the corresponding shutdown
                 event that the Net Vision will start sending the warning
                 message to the connected clients. The value is in units of
                 seconds"
                 ::= { shutdownParamEntry 4 }

upsControlWarningInterval OBJECT-TYPE
        SYNTAX INTEGER (0..32767)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The frequency of sending warning messages to the connected
                clients when the corresponding shutdown event occurs.
                The value is in units of seconds."
                ::= { shutdownParamEntry 5 }

upsControlWeeklyScheduleTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsControlWeeklyScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The table to schedule shutting down the ups by weekly."
        ::= { upsControl 5 }

upsControlWeeklyScheduleEntry OBJECT-TYPE
        SYNTAX UpsControlWeeklyScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The entries for each day."
        INDEX  { upsControlWeeklyIndex }
        ::= {upsControlWeeklyScheduleTable 1 }

UpsControlWeeklyScheduleEntry ::= SEQUENCE {
                upsControlWeeklyIndex
                        INTEGER,
                upsControlWeeklyShutdownDay
                        INTEGER,
                upsControlWeeklyShutdownTime
                        DisplayString,
                upsControlWeeklyRestartDay
                        INTEGER,
                upsControlWeeklyRestartTime
                        DisplayString
        }

upsControlWeeklyIndex OBJECT-TYPE
        SYNTAX INTEGER(1..7)    
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index of scheduled events."
        ::= { upsControlWeeklyScheduleEntry 1 }

upsControlWeeklyShutdownDay    OBJECT-TYPE
        SYNTAX  INTEGER {
                sunday(1),
                monday(2),
                tuesday(3),
                wednesday(4),
                thursday(5),
                friday(6),
                saturday(7),
                none(8)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The weekday on which the UPS should shut down."
        ::= { upsControlWeeklyScheduleEntry 2 }

upsControlWeeklyShutdownTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
         "The time that the process of shutting down the UPS will be initiated
          in hh:mm:ss format."
        ::= { upsControlWeeklyScheduleEntry 3 }

upsControlWeeklyRestartDay     OBJECT-TYPE
        SYNTAX  INTEGER {
                sunday(1),
                monday(2),
                tuesday(3),
                wednesday(4),
                thursday(5),
                friday(6),
                saturday(7),
                none(8)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The weekday on which the UPS should restart"

        ::= { upsControlWeeklyScheduleEntry 4 }

upsControlWeeklyRestartTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time the UPS will restart in hh:mm:ss format."
        ::= { upsControlWeeklyScheduleEntry 5 }

upsControlSpecialScheduleTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsControlSpecialScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The table to schedule shutting down the ups."
        ::= { upsControl 6 }

upsControlSpecialScheduleEntry OBJECT-TYPE
        SYNTAX UpsControlSpecialScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The entries for each day."
        INDEX  { upsControlSpecialIndex }
        ::= {upsControlSpecialScheduleTable 1 }

UpsControlSpecialScheduleEntry ::= SEQUENCE {
                upsControlSpecialIndex
                        INTEGER,
                upsControlSpecialShutdownDay
                        DisplayString,
                upsControlSpecialShutdownTime
                        DisplayString,
                upsControlSpecialRestartDay
                        DisplayString,
                upsControlSpecialRestartTime
                        DisplayString
        }

upsControlSpecialIndex OBJECT-TYPE
        SYNTAX INTEGER(1..8)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index of scheduled events."
        ::= { upsControlSpecialScheduleEntry 1 }

upsControlSpecialShutdownDay    OBJECT-TYPE
        SYNTAX DisplayString (SIZE (10..10))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date on which the UPS should shut down in dd/mm/yyyy
                 format."
         ::= { upsControlSpecialScheduleEntry 2 }

upsControlSpecialShutdownTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
         "The time that the process of shutting down the UPS will be initiated
          in hh:mm:ss format"
        ::= { upsControlSpecialScheduleEntry 3 }

upsControlSpecialRestartDay     OBJECT-TYPE
        SYNTAX DisplayString (SIZE (10..10))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date on which the UPS should restart in dd/mm/yyyy format"

        ::= { upsControlSpecialScheduleEntry 4 }

upsControlSpecialRestartTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time the UPS will restart in hh:mm:ss format."
        ::= { upsControlSpecialScheduleEntry 5 }


upsControlEcoModeScheduleTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsControlEcoModeScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The table to schedule enable/disable ups eco/mode by weekly."
        ::= { upsControl 7 }

upsControlEcoModeScheduleEntry OBJECT-TYPE
        SYNTAX UpsControlEcoModeScheduleEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The entries for each day."
        INDEX  { upsControlEcoModeIndex }
        ::= {upsControlEcoModeScheduleTable 1 }

UpsControlEcoModeScheduleEntry ::= SEQUENCE {
                upsControlEcoModeIndex
                        INTEGER,
                upsControlEcoModeStartDay
                        INTEGER,
                upsControlEcoModeStartTime
                        DisplayString,
                upsControlEcoModeEndDay
                        INTEGER,
                upsControlEcoModeEndTime
                        DisplayString
        }

upsControlEcoModeIndex OBJECT-TYPE
        SYNTAX INTEGER(1..7)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index of scheduled events."
        ::= { upsControlEcoModeScheduleEntry 1 }

upsControlEcoModeStartDay    OBJECT-TYPE
        SYNTAX  INTEGER {
                sunday(1),
                monday(2),
                tuesday(3),
                wednesday(4),
                thursday(5),
                friday(6),
                saturday(7),
                none(8)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The weekday on which the UPS Eco/Mode should enable."
        ::= { upsControlEcoModeScheduleEntry 2 }

upsControlEcoModeStartTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
         "The time that the UPS Eco/Mode will be enabled, in hh:mm:ss format."
        ::= { upsControlEcoModeScheduleEntry 3 }

upsControlEcoModeEndDay     OBJECT-TYPE
        SYNTAX  INTEGER {
                sunday(1),
                monday(2),
                tuesday(3),
                wednesday(4),
                thursday(5),
                friday(6),
                saturday(7),
                none(8)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The weekday on which the UPS Eco/Mode should disable"

        ::= { upsControlEcoModeScheduleEntry 4 }

upsControlEcoModeEndTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (5..5))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time the UPS Eco/Mode will disabled,  in hh:mm:ss format."
        ::= { upsControlEcoModeScheduleEntry 5 }


-- ===========================================================================
--
-- upsConfig
--
-- ===========================================================================

upsConfigNomKva OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "UPS Nominal in 0.1 kVA"
     ::= { upsConfig 1 }

upsConfigNbrUnit OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Number of Units installed in the system"
     ::= { upsConfig 2 }

upsConfigUnitKva OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "UNIT Nominal kVA"
     ::= { upsConfig 3 }

upsConfigRemoteCtrl OBJECT-TYPE
     SYNTAX INTEGER
     ACCESS read-only
     STATUS mandatory
     DESCRIPTION
         "Set to 1 if remote controls are enabled by UPS"
     ::= { upsConfig 4 }

upsDevicesTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsDevicesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The devices powered by UPS and registered to NET VISION"
        ::= { upsConfig 5 }

upsDevicesEntry OBJECT-TYPE
        SYNTAX UpsDevicesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The devices protected by NET VISION"
        INDEX  { indexOfDevice}
        ::= { upsDevicesTable 1 }

UpsDevicesEntry ::=
        SEQUENCE {
                indexOfDevice
                        NonNegativeInteger,
                addrOfDevice
                        DisplayString,
                nameOfDevice
                        DisplayString,
                timeOfConnection
                        DisplayString,
                statusOfConnection
                        INTEGER,
                severityOfConnection
                        INTEGER
        }

indexOfDevice OBJECT-TYPE
        SYNTAX NonNegativeInteger
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index of the device that is powered from UPS."
        ::= { upsDevicesEntry 1 }

addrOfDevice OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..31))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The ip address of the device."
        ::= { upsDevicesEntry 2 }

nameOfDevice OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..31))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The name/description of the device powered from UPS."
        ::= { upsDevicesEntry 3 }

timeOfConnection OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device registered to NET VISION"
        ::= { upsDevicesEntry 4 }

statusOfConnection OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device status connection"
        ::= { upsDevicesEntry 5 }

severityOfConnection OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The device severity"
        ::= { upsDevicesEntry 6 }

-- ===========================================================================
--
-- upsAgent
--
-- ===========================================================================

upsAgentIpaddress OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The ip address that NMS can identify the managed
                device"
        ::= { upsAgent 1}

upsAgentGateway OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The default gateway that allow device managed
                through routers "
        ::= { upsAgent 2}

upsAgentSubnetMask OBJECT-TYPE
        SYNTAX IpAddress
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " Internet address subnet mask"
        ::= { upsAgent 3}

upsAgentDate OBJECT-TYPE
        SYNTAX DisplayString (SIZE (10..10))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The date in agent, format is (dd/mm/yyyy)"
        ::= { upsAgent 4}

upsAgentTime OBJECT-TYPE
        SYNTAX DisplayString (SIZE (8..8))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The time in agent, format is (hh:mm:ss)"
        ::= { upsAgent 5}


upsAgentNtpTimeServer       OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { upsAgent 6 }

upsAgentNtpTimeZone         OBJECT-TYPE
        SYNTAX  INTEGER {
            gmt1200dateLineWest(1),
            gmt1200kwajalein(2),
            gmt1100samoa(3),
            gmt1000hawaii(4),
            gmt0900alaska(5),
            gmt0800tijuana(6),
            gmt0700arizona(7),
            gmt0700chihuahua(8),
            gmt0700mountain(9),
            gmt0600camerica(10),
            gmt0600ctime(11), 
            gmt0600guadalajara(12),
            gmt0600saskatchewan(13),
            gmt0500quito(14),
            gmt0500etime(15), 
            gmt0500indiana(16), 
            gmt0400atime(17),
            gmt0400caracas(18),
            gmt0400santiago(19),
            gmt0330newfoundland(20),
            gmt0300brasilia(21),
            gmt0300georgetown(22),
            gmt0300greenland(23),
            gmt0200atlantic(24),
            gmt0100azores(25),
            gmt0100cvi(26),
            gmt0000monrovia(27),
            gmt0000london(28),
            gmt0100vienna(29),
            gmt0100prague(30),
            gmt0100paris(31),
            gmt0100zagreb(32),
            gmt0100wcafrica(33),
            gmt0200minsk(34),
            gmt0200bucharest(35),
            gmt0200cairo(36),
            gmt0200pretoria(37),
            gmt0200vilnius(38),
            gmt0200jerusalem(39),
            gmt0300maghdad(40),
            gmt0300riyadh(41),
            gmt0300volgograd(42),
            gmt0300nairobi(43),
            gmt0330tehran(44),
            gmt0400muscat(45),
            gmt0400yerevan(46),
            gmt0430kabul(47),
            gmt0500ekaterinburg(48),
            gmt0500tashkent(49),
            gmt0530calcutta(50),
            gmt0530mumbai(51),
            gmt0545kathmandu(52),
            gmt0600novosibirsk(53),
            gmt0600dhaka(54),
            gmt0600jayawardenepura(55),
            gmt0630rangoon(56),
            gmt0700bangkok(57),
            gmt0700krasnoyarsk(58),
            gmt0800beijing(59),
            gmt0800irkutsk(60),
            gmt0800singapore(61),
            gmt0800perth(62),
            gmt0800taipei(63),
            gmt0900tokyo(64),
            gmt0900seoul(65),
            gmt0900yakutsk(66),
            gmt0930adelaide(67),
            gmt0930darwin(68),
            gmt1000brisbane(69),
            gmt1000canberra(70),
            gmt1000guam(71),
            gmt1000hobart(72),
            gmt1000vladivostok(73),
            gmt1100magadan(74),
            gmt1200auckland(75),
            gmt1200fiji(76),
            gmt1300alofa(77)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                ""
        ::= { upsAgent 7 }

upsAgentHistoryLogFrequency OBJECT-TYPE
        SYNTAX INTEGER (5..28800) -- in seconds
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The frequency of the updation of the history log. The value
                 is in seconds"
        ::= { upsAgent 8 }

upsAgentExtHistoryLogFrequency      OBJECT-TYPE
        SYNTAX INTEGER (3..10080) -- in minutes
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                 "The ups parameters are sampled at the rate governed by the
                  mconfigHistroyLogFrequency. These sampled values are further
                  conslidated over period of time which is determined by this
                  object."
        ::= { upsAgent 9 }

upsAgentPollRate OBJECT-TYPE
        SYNTAX INTEGER (3..999) -- in seconds
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                " The frequency that proxy agent polls the connected
                UPS in JBUS protocol. (unit : second)"
        ::= { upsAgent 10}

upsAgentBaudRate OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The serial port communication speed. only 9600 allowed"
        ::= { upsAgent 11}

upsAgentDhcpStatue OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable DHCP/BootP capability"
        ::= { upsAgent 12}

upsAgentTelnetStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable telnet access"
        ::= { upsAgent 13}

upsAgentTftpStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                enabled(1),
                disabled(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Enable or disable network upgrade capability"
        ::= { upsAgent 14}

upsAgentResetToDefault OBJECT-TYPE
        SYNTAX  INTEGER {
                reset(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Reset all parameters of Net Vision to default value"
        ::= { upsAgent 15}

upsAgentRestart OBJECT-TYPE
        SYNTAX  INTEGER {
                restart(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Restart Net Vision"
        ::= { upsAgent 16}

upsAgentClearAgentLog OBJECT-TYPE
        SYNTAX  INTEGER {
                clear(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Clear agent log data"
        ::= { upsAgent 17}

upsAgentClearEventLog OBJECT-TYPE
        SYNTAX  INTEGER {
                clear(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Clear event log data"
        ::= { upsAgent 18}

upsAgentClearExtHistoryLog OBJECT-TYPE
        SYNTAX  INTEGER {
                clear(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Clear extented history log data"
        ::= { upsAgent 19}

upsAgentClearHistoryLog OBJECT-TYPE
        SYNTAX  INTEGER {
                clear(1),
                nothing(2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "Clear history log data"
        ::= { upsAgent 20}

upsAgentTrapsReceiversTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsAgentTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers to send traps to.  The number of
                 entries is given by the value of upsAgentNumTrapReceivers"
        ::= { upsAgent 21}

upsAgentTrapsReceiversEntry OBJECT-TYPE
        SYNTAX UpsAgentTrapsReceiversEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers to send traps to."
        INDEX  { trapsIndex}
        ::= { upsAgentTrapsReceiversTable 1 }

UpsAgentTrapsReceiversEntry ::= SEQUENCE{
                trapsIndex
                    INTEGER,
                trapsReceiverAddr
                    DisplayString,
                receiverCommunityString
                    DisplayString,
                receiverNmstype
                    INTEGER
--                receiverDescription
--                    DisplayString
        }

trapsIndex OBJECT-TYPE
        SYNTAX INTEGER(1..8)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a trap receiver entry."
        ::= { upsAgentTrapsReceiversEntry 1 }

trapsReceiverAddr OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the manager to send a trap to."
        ::= { upsAgentTrapsReceiversEntry 2 }

receiverCommunityString OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..15))
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The community name to use in the trap when sent to the manager."
        ::= { upsAgentTrapsReceiversEntry 3 }

receiverNmstype OBJECT-TYPE
        SYNTAX  INTEGER {
                none(1),
                rfc1628-trap(2),
                netVision-trap(3)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The trap group that NMS desired."
        ::= { upsAgentTrapsReceiversEntry 4 }

--receiverDescription OBJECT-TYPE
--        SYNTAX DisplayString (SIZE(0..31))
--        ACCESS read-write
--        STATUS mandatory
--        DESCRIPTION
--                "Description of trap receivers"
--        ::= { upsAgentTrapsReceiversEntry 5 }

upsAgentFirewallControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF UpsAgentFirewallControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "A list of managers which can access Net Vision with private
                community string."
        ::= { upsAgent 22}

upsAgentFirewallControlEntry OBJECT-TYPE
        SYNTAX UpsAgentFirewallControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
                "The managers."
        INDEX  { trapsIndex}
        ::= { upsAgentFirewallControlTable 1 }

UpsAgentFirewallControlEntry ::= SEQUENCE {
                firewallIndex           INTEGER,
                firewallControlAddr     DisplayString,
                firewallPrefixLength    INTEGER,
                firewallActionMode      INTEGER
                }


firewallIndex OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The index to a firewall entry."
        ::= { upsAgentFirewallControlEntry 1 }

firewallControlAddr OBJECT-TYPE
        SYNTAX DisplayString
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The IP address of the firewall "
        ::= { upsAgentFirewallControlEntry 2 }


firewallPrefixLength      OBJECT-TYPE
        SYNTAX INTEGER (1..64)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                 "The firewall prefix length."
        ::= { upsAgentFirewallControlEntry 3 }

firewallActionMode OBJECT-TYPE
        SYNTAX  INTEGER {
                accept (1),
                reject (2)
                }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
                "The firewall action mode"
        ::= { upsAgentFirewallControlEntry 4 }


upsAgentMibVersion OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The version of MIB spec."
        ::= { upsAgent 23 }
        
-- ===========================================================================
--
-- emdStatus
--
-- ===========================================================================

emdSatatusTemperature OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The measurement of EMD temperature, in 0.1 degree"
        ::= { emdStatus 1}

emdSatatusHumidity OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The measurement of EMD humidity, in 0.1 degree"
        ::= { emdStatus 2}

emdStatusIn1Active OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                notActived(2),
                actived(3)
                }        
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The input 1 has been detected as Active"
        ::= { emdStatus 3}

emdStatusIn2Active OBJECT-TYPE
        SYNTAX  INTEGER {
                disabled(1),
                notActived(2),
                actived(3)
                }        
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
                "The input 2 has been detected as Active"
        ::= { emdStatus 4}

-- ===========================================================================
-- upsTraps
--
-- Traps group
-- ===========================================================================

   -- This section defines the well-known notifications sent by
   -- UPS agents.
   -- Care must be taken to insure that no particular notification
   -- is sent to a single receiving entity more often than once
   -- every five seconds.

   upsTrapOnBattery TRAP-TYPE
       ENTERPRISE upsTraps
       VARIABLES { upsEstimatedMinutesRemaining, upsSecondsOnBattery }
       DESCRIPTION
               "WARNING:The UPS is operating on battery power.  This trap is
               persistent and is resent at one minute intervals until
               the UPS either turns off or is no longer running on
               battery."
     ::= 1

   upsTrapTestCompleted TRAP-TYPE
       ENTERPRISE upsTraps
       DESCRIPTION
               "INFORMATION:This trap is sent upon completion of a UPS diagnostic
               test."
     ::= 2

   upsTrapAlarmEntryAdded TRAP-TYPE
       ENTERPRISE upsTraps
       VARIABLES { upsAlarmId, upsAlarmDescr }
       DESCRIPTION
               "WARNING:This trap is sent each time an alarm is inserted into
               to the alarm table.  It is sent on the insertion of
               all alarms except for upsAlarmOnBattery and
               upsAlarmTestInProgress."
     ::= 3

   upsTrapAlarmEntryRemoved TRAP-TYPE
       ENTERPRISE upsTraps
       VARIABLES { upsAlarmId, upsAlarmDescr }
       DESCRIPTION
               "INFORMATION:This trap is sent each time an alarm is removed from
               the alarm table.  It is sent on the removal of all
               alarms except for upsAlarmTestInProgress."
     ::= 4
     

   upsTrapImminentStop TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The UPS is near to switch off the output power."
     ::= 5

   upsTrapOverload TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: The UPS output is in overload. Output load rate more than 100%"
     ::= 6

   upsTrapRedundancyLost TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: Redundancy is lost."
     ::= 7

   upsTrapBatteryCircuitOpen TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The battery has been disconnected from UPS"
     ::= 8

   upsTrapBatteryDischarged TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The battery has been detected as discharged."
     ::= 9

   upsTrapBatteryLow TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The battery is near of the end of backup time."
     ::= 10

   upsTrapBatteryAlarm TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: The battery is in alarm."
     ::= 11

   upsTrapUpsCriticalAlarm TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: A critical alarm has been detected on the UPS."
     ::= 12
     
   upsTrapLoadOFF TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The load has been disconnected from the UPS. LOAD OFF."
     ::= 13

   upsTrapCommunicationLost TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: UPS is no more communicating with the agent."
     ::= 14

   upsTrapOnBatteryPower TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: The UPS has switched to battery backup power."
     ::= 15

   upsTrapBatteryTestfailed TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: The Battery test has detected a weak battery."
     ::= 16

   upsTrapTemperatureAlarm TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: The UPS internal temperature has reached the threshold."
     ::= 17

   upsTrapOnBypass TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: Load supplied by automatic Bypass."
     ::= 18

   upsTrapUpsPreventiveAlarm TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: A preventive alarm has been detected by the UPS."
     ::= 19

   upsTrapShutdownWarning TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: A warning message has be sent to shutdown agent."
     ::= 20

   upsTrapShutdownrequest TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "WARNING: A shutdown command has been sent to agent."
     ::= 21
     
   upsTrapUpsNormal TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
          "INFORMATION: The UPS status is normal. Load protected by UPS"
     ::= 22

   upsTrapPowerRestored TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
          "INFORMATION: The Input supply has been restored"
     ::= 23

  upsTrapAlarmCancelled TRAP-TYPE
       ENTERPRISE upsTraps
       DESCRIPTION
          "INFORMATION: Alarm cancelled. All alarms are disabled"
     ::= 24

  upsTrapComEstablished TRAP-TYPE
       ENTERPRISE upsTraps
       DESCRIPTION
          "INFORMATION: The communication between UPS and the agent has been restored"
     ::= 25

  upsTrapShutdwonCancelled TRAP-TYPE
       ENTERPRISE upsTraps
       DESCRIPTION
          "INFORMATION: The UPS has cancelled the shutdown procedure to agent"
     ::= 26

  upsTrapAgentRestarting TRAP-TYPE
       ENTERPRISE upsTraps
       DESCRIPTION
          "INFORMATION: NET VISION is restarting"
     ::= 27
 
    upsTrapEmdTempLow TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: EMD Sensor detected low temperature."
    ::= 28

    upsTrapEmdTempNotLow TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "INFORMATION: EMD Sensor Not under low temperature."
    ::= 29

    upsTrapEmdTempHigh TRAP-TYPE
        ENTERPRISE upsTraps
    DESCRIPTION
            "CRITICAL: EMD Sensor detected high temperature."
    ::= 30

    upsTrapEmdTempNotHigh TRAP-TYPE
        ENTERPRISE upsTraps
    DESCRIPTION
            "INFORMATION: EMD Sensor Not over high temperature."
    ::= 31

    upsTrapEmdHumidityLow TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: EMD Sensor detected low humidity."
    ::= 32

    upsTrapEmdHumidityNotLow TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "INFORMATION: EMD Sensor Not under low humidity."
    ::= 33

    upsTrapEmdHumidityHigh TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: EMD Sensor detected high humidity."
    ::= 34

    upsTrapEmdHumidityNotHigh TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "INFORMATION: EMD Sensor Not over high humidity."
    ::= 35

    upsTrapEmdFirstInputActive TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The <customized> input is active."
    ::= 36

    upsTrapEmdFirstInputRestored TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "INFORMATION: The <customized> input is restored."
    ::= 37

    upsTrapEmdSecondInputActive TRAP-TYPE
        ENTERPRISE upsTraps
        DESCRIPTION
            "CRITICAL: The <customized> input is active."
    ::= 38

    upsTrapEmdSecondInputRestored TRAP-TYPE
         ENTERPRISE upsTraps
         DESCRIPTION
             "INFORMATION: The <customized> input is restored."
    ::= 39

   END