-- SOCOMEC MIB
-- UPS MIB for SOCOMEC UPS - Uninterruptible Power Supplies
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) socomec(4555)
-- software(1) network(1) netvision(7) }
-- ==============================================================================================
-- vers. 7.00: new version for Net Vision 7 platform by NVO.
-- vers. 7.10: release.
-- vers. 7.11: OutputGlobalkW
SOCOMECUPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, TimeStamp, TimeInterval, TestAndIncr,
AutonomousType
FROM SNMPv2-TC
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
PositiveInteger ::= INTEGER (1..2147483647)
NonNegativeInteger ::= INTEGER (1..2147483647)
socomec OBJECT IDENTIFIER ::= { enterprises 4555 }
software OBJECT IDENTIFIER ::= { socomec 1 }
network OBJECT IDENTIFIER ::= { software 1 }
netvision7 OBJECT IDENTIFIER ::= { network 7 }
upsObjects OBJECT IDENTIFIER ::= { netvision7 1 }
upsTraps OBJECT IDENTIFIER ::= { netvision7 2 }
upsIdent OBJECT IDENTIFIER ::= { upsObjects 1 }
upsBattery OBJECT IDENTIFIER ::= { upsObjects 2 }
upsInput OBJECT IDENTIFIER ::= { upsObjects 3 }
upsOutput OBJECT IDENTIFIER ::= { upsObjects 4 }
upsBypass OBJECT IDENTIFIER ::= { upsObjects 5 }
upsAlarm OBJECT IDENTIFIER ::= { upsObjects 6 }
upsControl OBJECT IDENTIFIER ::= { upsObjects 7 }
upsConfig OBJECT IDENTIFIER ::= { upsObjects 8 }
upsAgent OBJECT IDENTIFIER ::= { upsObjects 9 }
emdStatus OBJECT IDENTIFIER ::= { upsObjects 10 }
-- ===========================================================================
--
-- upsIdentification
--
-- All objects in this group except for upsIdentUserRef and
-- upsIdentUserLocation are set at device initialization
-- and remain static.
--
-- ===========================================================================
upsIdentModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS Model designation."
::= { upsIdent 1 }
upsIdentSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..19))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS Serial number."
::= { upsIdent 2 }
upsIdentUserRef OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS Reference."
::= { upsIdent 3 }
upsIdentUserLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..11))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS Location."
::= { upsIdent 4 }
upsIdentAgentSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS Net Vision software version."
::= { upsIdent 5 }
-- ===========================================================================
-- upsBattery
--
-- The Battery group.
-- ===========================================================================
upsBatteryStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
batteryNormal(2),
batteryCharging(3),
batteryTest(4),
batteryDischarging(5),
batteryLow(6),
batteryDepleted(7),
batteryFailure(8),
batteryDisconnected(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present battery status"
::= { upsBattery 1 }
upsSecondsOnBattery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the unit is on battery power, the elapsed time
since the UPS last switched to battery power, or the
time since the network management subsystem was last
restarted, whichever is less. -1 shall be returned
if the unit is not on battery power."
::= { upsBattery 2 }
upsEstimatedMinutesRemaining OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An estimate of the time to battery charge depletion
under the present load conditions. Compute when UPS is
on battery power"
::= { upsBattery 3 }
upsEstimatedChargeRemaining OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An estimate of the battery charge remaining expressed
as a percent of full charge."
::= { upsBattery 4 }
upsBatteryVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The magnitude of the present battery voltage in 0.1 Volt DC."
::= { upsBattery 5 }
upsBatteryTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ambient temperature at or near the UPS Battery casing in 0.1 degree"
::= { upsBattery 6 }
-- vers. 7.10
upsAmbientTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ambient temperature inside the UPS in 0.1 degree"
::= { upsBattery 7 }
-- vers. 7.10
upsBatteryCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The battry current in 0.1 Amp"
::= { upsBattery 8 }
-- ===========================================================================
-- upsInput
--
-- Input group.
-- ===========================================================================
upsInputNumLines OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input lines utilized in this device.
This variable indicates the number of rows in the
input table."
::= { upsInput 1 }
upsInputFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current input frequency to the UPS system in 0.1 HZ."
::= { upsInput 2 }
upsInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of input table entries. The number of entries
is given by the value of upsInputNumLines."
::= { upsInput 3 }
upsInputEntry OBJECT-TYPE
SYNTAX UpsInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular input line."
INDEX { upsInputLineIndex }
::= { upsInputTable 1 }
UpsInputEntry ::= SEQUENCE {
upsInputLineIndex INTEGER,
upsInputVoltage INTEGER,
upsInputCurrent INTEGER,
upsInputVoltageMax INTEGER,
upsInputVoltageMin INTEGER
}
upsInputLineIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { upsInputEntry 1 }
upsInputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input utility line voltage in 0.1 volts."
::= { upsInputEntry 2 }
upsInputCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The magnitude of the present input current in 0.1 A."
::= { upsInputEntry 3 }
upsInputVoltageMax OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum utility line voltage in 0.1 VAC for last 1 minute."
::= { upsInputEntry 4 }
upsInputVoltageMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum utility line voltage in 0.1 VAC for last 1 minute."
::= { upsInputEntry 5 }
-- ===========================================================================
-- upsOutput
--
-- Output group
-- ===========================================================================
upsOutputSource OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
onMaintenBypass(2),
onInverter(3),
normalMode(4),
ecoMode(5),
onBypass(6),
standby(7),
upsOff(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present source of output power."
::= { upsOutput 1 }
upsOutputFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current output frequency of the UPS system in 0.1 of HZ."
::= { upsOutput 2 }
upsOutputNumLines OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of output lines utilized in this device.
This variable indicates the number of rows in the
output table."
::= { upsOutput 3 }
upsOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of output table entries. The number of
entries is given by the value of upsOutputNumLines."
::= { upsOutput 4 }
upsOutputEntry OBJECT-TYPE
SYNTAX UpsOutputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular output line."
INDEX { upsOutputLineIndex }
::= { upsOutputTable 1 }
UpsOutputEntry ::=
SEQUENCE {
upsOutputLineIndex INTEGER,
upsOutputVoltage INTEGER,
upsOutputCurrent INTEGER,
upsOutputPercentLoad INTEGER,
upsOutputKva INTEGER,
upsOutputKw INTEGER
}
upsOutputLineIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output line identifier."
::= { upsOutputEntry 1 }
upsOutputVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output voltage of the UPS system in 0.1 volts."
::= { upsOutputEntry 2 }
upsOutputCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output current of the UPS system in 0.1 Amps."
::= { upsOutputEntry 3 }
upsOutputPercentLoad OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percentage of the UPS power capacity presently
being used on this output line"
::= { upsOutputEntry 4 }
upsOutputKva OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output apparent power of the UPS in 0.1 kVA."
::= { upsOutputEntry 5 }
upsOutputKw OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output apparent power of the UPS in 0.1 kW."
::= { upsOutputEntry 6 }
-- vers. 7.10
upsOutputGlobalkVA OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output global apparent power of the UPS in 0.1 kVA."
::= { upsOutput 5 }
-- vers. 7.11
upsOutputGlobalkW OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output global apparent power of the UPS in 0.1 kW."
::= { upsOutput 6 }
-- vers. 7.10
upsOutputLoadRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output global Load Rate."
::= { upsOutput 7 }
-- ===========================================================================
-- upsBypass
-- ===========================================================================
upsBypassFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present bypass frequency in 0.1 Hz."
::= { upsBypass 1 }
upsBypassNumLines OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bypass lines utilized in this device.
This entry indicates the number of rows in the bypass
table."
::= { upsBypass 2 }
upsBypassTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsBypassEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of bypass table entries. The number of
entries is given by the value of upsBypassNumLines."
::= { upsBypass 3 }
upsBypassEntry OBJECT-TYPE
SYNTAX UpsBypassEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular bypass input."
INDEX { upsBypassLineIndex }
::= { upsBypassTable 1 }
UpsBypassEntry ::=
SEQUENCE {
upsBypassLineIndex INTEGER,
upsBypassVoltage INTEGER,
upsBypassCurrent INTEGER
}
upsBypassLineIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bypass line identifier."
::= { upsBypassEntry 1 }
upsBypassVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present bypass voltage of the UPS system in 0.1 volts."
::= { upsBypassEntry 2 }
upsBypassCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present bypass current of the UPS system in 0.1 Amps."
::= { upsBypassEntry 3 }
-- ===========================================================================
-- upsAlarm
-- See Section 4 for Status/Alarm details for all variables
-- ===========================================================================
upsAlarmsPresent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The present number of active alarm conditions."
::= { upsAlarm 1 }
upsAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of alarm table entries. The table contains
zero, one, or many rows at any moment, depending upon
the number of alarm conditions in effect. The table
is initially empty at agent startup. The agent
creates a row in the table each time a condition is
detected and deletes that row when that condition no
longer pertains. The agent creates the first row with
upsAlarmId equal to 1, and increments the value of
upsAlarmId each time a new row is created, wrapping to
the first free value greater than or equal to 1 when
the maximum value of upsAlarmId would otherwise be
exceeded. Consequently, after multiple operations,
the table may become sparse, e.g., containing entries
for rows 95, 100, 101, and 203 and the entries should
not be assumed to be in chronological order because
upsAlarmId might have wrapped.
Alarms are named by an OBJECT IDENTIFIER,
upsAlarmDescr, to allow a single table to
reflect well known alarms plus alarms defined by a
particular implementation, i.e., as documented in the
private enterprise MIB definition for the device. No
two rows will have the same value of upsAlarmDescr,
since alarms define conditions. In order to meet this
requirement, care should be taken in the definition of
alarm conditions to insure that a system cannot enter
the same condition multiple times simultaneously.
The number of rows in the table at any given time is
reflected by the value of upsAlarmsPresent."
::= { upsAlarm 2 }
upsAlarmEntry OBJECT-TYPE
SYNTAX UpsAlarmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry containing information applicable to a
particular alarm."
INDEX { upsAlarmId }
::= { upsAlarmTable 1 }
UpsAlarmEntry ::=
SEQUENCE {
upsAlarmId PositiveInteger,
upsAlarmDescr AutonomousType,
upsAlarmTime TimeStamp,
upsAlarmExtDes DisplayString
}
-- ===========================================================================
-- Agent item
-- upsAlarmTable/upsAlarmEntry/upsAlarmId
-- ===========================================================================
upsAlarmId OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique identifier for an alarm condition. This
value must remain constant."
::= { upsAlarmEntry 1 }
upsAlarmDescr OBJECT-TYPE
SYNTAX AutonomousType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A reference to an alarm description object. The
object referenced should not be accessible, but rather
be used to provide a unique description of the alarm
condition."
::= { upsAlarmEntry 2 }
upsAlarmTime OBJECT-TYPE
SYNTAX TimeStamp
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the alarm condition was
detected. If the alarm condition was detected at the
time of agent startup and presumably existed before
agent startup, the value of upsAlarmTime shall equal
0."
::= { upsAlarmEntry 3 }
upsAlarmExtDes OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Extra description."
::= { upsAlarmEntry 4 }
upsWellKnownAlarms OBJECT IDENTIFIER ::= { upsAlarm 3 }
upsAlarmImminentStop OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPS in imminent stop. Load will switch off. (A000)"
::= { upsWellKnownAlarms 1 }
upsAlarmOverload OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output load exceeds the UPS output capacity. (A001)"
::= { upsWellKnownAlarms 2 }
upsAlarmTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPS temperature is out of tolerance. (A002)"
::= { upsWellKnownAlarms 3 }
upsAlarmTransferLock OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Automatic and manual transfer are locked. (A003)"
::= { upsWellKnownAlarms 4 }
upsAlarmAutoTransferImpossible OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Automatic transfer is disabled.
Inverter and bypass sources are not synchronized (A004)"
::= { upsWellKnownAlarms 5 }
upsAlarmInsufficientResources OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Insufficient resources alarm.
The load cannot by supplied by alternate source (A005)"
::= { upsWellKnownAlarms 6 }
upsAlarmRedundancyLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Redundancy lost alarm. (A006)"
::= { upsWellKnownAlarms 7 }
upsAlarmOutputShortCircuit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An output short-circuit has been detected by UPS. (A007)"
::= { upsWellKnownAlarms 8 }
upsAlarmMaintenance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS requests a maintenance service check. (A012)"
::= { upsWellKnownAlarms 9 }
upsAlarmRemoteService OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS requests a remote service action. (A013)"
::= { upsWellKnownAlarms 10 }
upsAlarmGeneralFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A general fault in the UPS has been detected.
One of UPS alarm is present. (A015)"
::= { upsWellKnownAlarms 11 }
upsAlarmBatteryCircuitOpen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Battery circuit open. Battery breaker or fuse open. (A016)"
::= { upsWellKnownAlarms 12 }
upsAlarmBatteryDischarged OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS will be unable to sustain the present load
when and if the utility power is lost.
The Battery is discharched. (A017)"
::= { upsWellKnownAlarms 13 }
upsAlarmLowBattery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The remaining battery run-time is less than or equal
to battery low threshold. (A018)"
::= { upsWellKnownAlarms 14 }
upsAlarmOnBattery OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS is drawing power from the batteries. (A019)"
::= { upsWellKnownAlarms 15 }
upsAlarmBatteryTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Battery Temperature Alarm. (A020)"
::= { upsWellKnownAlarms 16 }
upsAlarmBatteryRoom OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An external alarm has been detected in the Battery room.
This alarm depends on external sensor: gaz, temperature,
humidity or dry-contact. (A021)"
::= { upsWellKnownAlarms 17 }
upsAlarmBatteryTest OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The battery has been detected as weak during the test. (A022)"
::= { upsWellKnownAlarms 18 }
upsAlarmBatteryFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"One or more batteries have been determined to require replacement. (A027)"
::= { upsWellKnownAlarms 19 }
upsAlarmRectifierFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rectifier Critical alarm. (A032)"
::= { upsWellKnownAlarms 20 }
upsAlarmRectifierAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rectifier Preventive alarm. (A033)"
::= { upsWellKnownAlarms 21 }
upsAlarmRecInputBad OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"rectifier Input power supply is out of tolerance or absent. (A035)"
::= { upsWellKnownAlarms 22 }
upsAlarmGenSetGeneral OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gen-set general alarm.
coming from external dry-contact. (A036)"
::= { upsWellKnownAlarms 23 }
upsAlarmBatteryChargerFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Battery charger Critical Alarm. (A037)"
::= { upsWellKnownAlarms 24 }
upsAlarmBatteryChargerAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Battery charger Preventive Alarm. (A038)"
::= { upsWellKnownAlarms 25 }
upsAlarmInverterFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inverter Critical alarm. (A040)"
::= { upsWellKnownAlarms 26 }
upsAlarmInverterAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inverter preventive alarm. (A041)"
::= { upsWellKnownAlarms 27 }
upsAlarmBypassFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inverter Critical alarm. (A048)"
::= { upsWellKnownAlarms 28 }
upsAlarmBypassAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Inverter preventive alarm. (A049)"
::= { upsWellKnownAlarms 29 }
upsAlarmBypInputBad OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bypass Input power supply is out of tolerance or absent. (A050)"
::= { upsWellKnownAlarms 30 }
upsAlarmPhaseRotationFault OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Phase rotation fault. (A051)"
::= { upsWellKnownAlarms 31 }
upsAlarmFansFailure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Fans failure. (A054)"
::= { upsWellKnownAlarms 32 }
upsAlarmMaintenanceBypass OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintenance bypass alarm.
Output breaker and manual bypass breaker closed together. (A056)"
::= { upsWellKnownAlarms 33 }
upsAlarmUPSPowerOffActive OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPS power off has been activated by external device. (A059)"
::= { upsWellKnownAlarms 34 }
upsAlarmWrongConfiguration OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configuration data map corrupted, or wrong configuration. (A060)"
::= { upsWellKnownAlarms 35 }
upsAlarmInternalFailure OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Internal failure, or internal communication failure. (A061)"
::= { upsWellKnownAlarms 36 }
upsAlarmOptionalBoards OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optional boards alarm.
Board not present or wrong configuration (A062)"
::= { upsWellKnownAlarms 37 }
upsAlarmExternalAlarm1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"External Alarm 1.
Coming from ADC Card: Input set as alarm (A064)"
::= { upsWellKnownAlarms 38 }
upsAlarmExternalAlarm2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"External Alarm 2.
Coming from ADC Card: Input set as alarm (A065)"
::= { upsWellKnownAlarms 39 }
upsAlarmExternalAlarm3 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"External Alarm 3.
Coming from ADC Card: Input set as alarm (A066)"
::= { upsWellKnownAlarms 40 }
upsAlarmExternalAlarm4 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"External Alarm 4.
Coming from ADC Card: Input set as alarm (A067)"
::= { upsWellKnownAlarms 41 }
upsAlarmModule1Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 1 in parallel general alarm."
::= { upsWellKnownAlarms 42 }
upsAlarmModule2Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 2 in parallel general alarm."
::= { upsWellKnownAlarms 43 }
upsAlarmModule3Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 3 in parallel general alarm."
::= { upsWellKnownAlarms 44 }
upsAlarmModule4Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 4 in parallel general alarm."
::= { upsWellKnownAlarms 45 }
upsAlarmModule5Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 5 in parallel general alarm."
::= { upsWellKnownAlarms 46 }
upsAlarmModule6Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 6 in parallel general alarm."
::= { upsWellKnownAlarms 47 }
upsAlarmModule7Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 7 in parallel general alarm."
::= { upsWellKnownAlarms 48 }
upsAlarmModule8Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 8 in parallel general alarm."
::= { upsWellKnownAlarms 49 }
upsAlarmModule9Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 9 in parallel general alarm."
::= { upsWellKnownAlarms 50 }
upsAlarmModule10Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 10 in parallel general alarm."
::= { upsWellKnownAlarms 51 }
upsAlarmModule11Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 11 in parallel general alarm."
::= { upsWellKnownAlarms 52 }
upsAlarmModule12Alarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unit or Module 12 in parallel general alarm."
::= { upsWellKnownAlarms 53 }
upsAlarmAutoTestRunning OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS has launched the auto-test. (S030)"
::= { upsWellKnownAlarms 54 }
upsAlarmOnBypass OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Load supplied by automatic bypass.
Load not protected."
::= { upsWellKnownAlarms 55 }
upsAlarmUpsOutputOff OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The output of the UPS is in the off state.
Load OFF or UPS on standby mode."
::= { upsWellKnownAlarms 56 }
upsAlarmUpsSystemOff OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS system is in the off state.
Rectifier and Inverter are off."
::= { upsWellKnownAlarms 57 }
upsAlarmCommunicationLost OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The communication with UPS has been lost."
::= { upsWellKnownAlarms 58 }
upsAlarmShutdownPending OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The condition to shutdown servers has been detected.
The shutdown delay in underway."
::= { upsWellKnownAlarms 59 }
upsAlarmShutdownRequestt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shutdown command has been sent to servers agent."
::= { upsWellKnownAlarms 60 }
upsAlarmShutdownImminent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS will turn OFF,
according the standby schedule settings."
::= { upsWellKnownAlarms 61 }
upsAlarmAwaitingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The UPS output is in standby,
and the UPS is awaiting the return of input power."
::= { upsWellKnownAlarms 62 }
-- ===========================================================================
-- upsControl
--
-- ===========================================================================
upsControlStatusControl OBJECT-TYPE
SYNTAX INTEGER {
upsStandbyOn (1),
upsStandbyOff (2),
upsEcoMode (3),
upsNormalMode (4),
upsAlarmReset (5),
upsOnBypass (6),
upsOnInverter (7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object Control UPS status"
::= { upsControl 1 }
upsShutdownDelay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object set the delay time (in seconds) to turn UPS off after
Net Vision broadcast shutdown request to connected clients"
::= { upsControl 2 }
upsTurnOffAfterShutdown OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object enable/disable UPS turn off function after shutdown
process complete"
::= { upsControl 3 }
upsControlShutdownParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ShutdownParamEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table which describes the parameters for shutdown process
when shutdown event occurs"
::= { upsControl 4 }
shutdownParamEntry OBJECT-TYPE
SYNTAX ShutdownParamEntry
ACCESS not-accessible
STATUS mandatory
INDEX { upsControlEventIndex }
::= { upsControlShutdownParamTable 1 }
ShutdownParamEntry ::= SEQUENCE {
upsControlEventIndex
INTEGER,
upsControlEventStatus
INTEGER,
upsControlDelay
INTEGER,
upsControlFirstWarning
INTEGER,
upsControlWarningInterval
INTEGER
}
upsControlEventIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The shutdown event identification "
::= { shutdownParamEntry 1 }
upsControlEventStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
warning(2),
clientShutdown(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Status of the corresponding shutdown Event.
When set to disable(), shutdown process will not start when
corresponding event occurred."
::= { shutdownParamEntry 2 }
upsControlDelay OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay after the occurrence of the corresponding shutdown
event that Net Vision should issue shutdown request to
connected clients. For WeeklyScheduledShutdown and
SpecialScheduledShutdown, this is the time before the
configured Shutdown time when Net Vision will start sending the
warning message to the connected clients. The value is in
units of minutes."
::= { shutdownParamEntry 3 }
upsControlFirstWarning OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The delay after the occurrence of the corresponding shutdown
event that the Net Vision will start sending the warning
message to the connected clients. The value is in units of
seconds"
::= { shutdownParamEntry 4 }
upsControlWarningInterval OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The frequency of sending warning messages to the connected
clients when the corresponding shutdown event occurs.
The value is in units of seconds."
::= { shutdownParamEntry 5 }
upsControlWeeklyScheduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsControlWeeklyScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table to schedule shutting down the ups by weekly."
::= { upsControl 5 }
upsControlWeeklyScheduleEntry OBJECT-TYPE
SYNTAX UpsControlWeeklyScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entries for each day."
INDEX { upsControlWeeklyIndex }
::= {upsControlWeeklyScheduleTable 1 }
UpsControlWeeklyScheduleEntry ::= SEQUENCE {
upsControlWeeklyIndex
INTEGER,
upsControlWeeklyShutdownDay
INTEGER,
upsControlWeeklyShutdownTime
DisplayString,
upsControlWeeklyRestartDay
INTEGER,
upsControlWeeklyRestartTime
DisplayString
}
upsControlWeeklyIndex OBJECT-TYPE
SYNTAX INTEGER(1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of scheduled events."
::= { upsControlWeeklyScheduleEntry 1 }
upsControlWeeklyShutdownDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(1),
monday(2),
tuesday(3),
wednesday(4),
thursday(5),
friday(6),
saturday(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The weekday on which the UPS should shut down."
::= { upsControlWeeklyScheduleEntry 2 }
upsControlWeeklyShutdownTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time that the process of shutting down the UPS will be initiated
in hh:mm:ss format."
::= { upsControlWeeklyScheduleEntry 3 }
upsControlWeeklyRestartDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(1),
monday(2),
tuesday(3),
wednesday(4),
thursday(5),
friday(6),
saturday(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The weekday on which the UPS should restart"
::= { upsControlWeeklyScheduleEntry 4 }
upsControlWeeklyRestartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time the UPS will restart in hh:mm:ss format."
::= { upsControlWeeklyScheduleEntry 5 }
upsControlSpecialScheduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsControlSpecialScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table to schedule shutting down the ups."
::= { upsControl 6 }
upsControlSpecialScheduleEntry OBJECT-TYPE
SYNTAX UpsControlSpecialScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entries for each day."
INDEX { upsControlSpecialIndex }
::= {upsControlSpecialScheduleTable 1 }
UpsControlSpecialScheduleEntry ::= SEQUENCE {
upsControlSpecialIndex
INTEGER,
upsControlSpecialShutdownDay
DisplayString,
upsControlSpecialShutdownTime
DisplayString,
upsControlSpecialRestartDay
DisplayString,
upsControlSpecialRestartTime
DisplayString
}
upsControlSpecialIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of scheduled events."
::= { upsControlSpecialScheduleEntry 1 }
upsControlSpecialShutdownDay OBJECT-TYPE
SYNTAX DisplayString (SIZE (10..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The date on which the UPS should shut down in dd/mm/yyyy
format."
::= { upsControlSpecialScheduleEntry 2 }
upsControlSpecialShutdownTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time that the process of shutting down the UPS will be initiated
in hh:mm:ss format"
::= { upsControlSpecialScheduleEntry 3 }
upsControlSpecialRestartDay OBJECT-TYPE
SYNTAX DisplayString (SIZE (10..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The date on which the UPS should restart in dd/mm/yyyy format"
::= { upsControlSpecialScheduleEntry 4 }
upsControlSpecialRestartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time the UPS will restart in hh:mm:ss format."
::= { upsControlSpecialScheduleEntry 5 }
upsControlEcoModeScheduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsControlEcoModeScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table to schedule enable/disable ups eco/mode by weekly."
::= { upsControl 7 }
upsControlEcoModeScheduleEntry OBJECT-TYPE
SYNTAX UpsControlEcoModeScheduleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The entries for each day."
INDEX { upsControlEcoModeIndex }
::= {upsControlEcoModeScheduleTable 1 }
UpsControlEcoModeScheduleEntry ::= SEQUENCE {
upsControlEcoModeIndex
INTEGER,
upsControlEcoModeStartDay
INTEGER,
upsControlEcoModeStartTime
DisplayString,
upsControlEcoModeEndDay
INTEGER,
upsControlEcoModeEndTime
DisplayString
}
upsControlEcoModeIndex OBJECT-TYPE
SYNTAX INTEGER(1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of scheduled events."
::= { upsControlEcoModeScheduleEntry 1 }
upsControlEcoModeStartDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(1),
monday(2),
tuesday(3),
wednesday(4),
thursday(5),
friday(6),
saturday(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The weekday on which the UPS Eco/Mode should enable."
::= { upsControlEcoModeScheduleEntry 2 }
upsControlEcoModeStartTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time that the UPS Eco/Mode will be enabled, in hh:mm:ss format."
::= { upsControlEcoModeScheduleEntry 3 }
upsControlEcoModeEndDay OBJECT-TYPE
SYNTAX INTEGER {
sunday(1),
monday(2),
tuesday(3),
wednesday(4),
thursday(5),
friday(6),
saturday(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The weekday on which the UPS Eco/Mode should disable"
::= { upsControlEcoModeScheduleEntry 4 }
upsControlEcoModeEndTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time the UPS Eco/Mode will disabled, in hh:mm:ss format."
::= { upsControlEcoModeScheduleEntry 5 }
-- ===========================================================================
--
-- upsConfig
--
-- ===========================================================================
upsConfigNomKva OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPS Nominal in 0.1 kVA"
::= { upsConfig 1 }
upsConfigNbrUnit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Units installed in the system"
::= { upsConfig 2 }
upsConfigUnitKva OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UNIT Nominal kVA"
::= { upsConfig 3 }
upsConfigRemoteCtrl OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Set to 1 if remote controls are enabled by UPS"
::= { upsConfig 4 }
upsDevicesTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsDevicesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The devices powered by UPS and registered to NET VISION"
::= { upsConfig 5 }
upsDevicesEntry OBJECT-TYPE
SYNTAX UpsDevicesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The devices protected by NET VISION"
INDEX { indexOfDevice}
::= { upsDevicesTable 1 }
UpsDevicesEntry ::=
SEQUENCE {
indexOfDevice
NonNegativeInteger,
addrOfDevice
DisplayString,
nameOfDevice
DisplayString,
timeOfConnection
DisplayString,
statusOfConnection
INTEGER,
severityOfConnection
INTEGER
}
indexOfDevice OBJECT-TYPE
SYNTAX NonNegativeInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the device that is powered from UPS."
::= { upsDevicesEntry 1 }
addrOfDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ip address of the device."
::= { upsDevicesEntry 2 }
nameOfDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name/description of the device powered from UPS."
::= { upsDevicesEntry 3 }
timeOfConnection OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device registered to NET VISION"
::= { upsDevicesEntry 4 }
statusOfConnection OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device status connection"
::= { upsDevicesEntry 5 }
severityOfConnection OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device severity"
::= { upsDevicesEntry 6 }
-- ===========================================================================
--
-- upsAgent
--
-- ===========================================================================
upsAgentIpaddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The ip address that NMS can identify the managed
device"
::= { upsAgent 1}
upsAgentGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The default gateway that allow device managed
through routers "
::= { upsAgent 2}
upsAgentSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Internet address subnet mask"
::= { upsAgent 3}
upsAgentDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (10..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The date in agent, format is (dd/mm/yyyy)"
::= { upsAgent 4}
upsAgentTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time in agent, format is (hh:mm:ss)"
::= { upsAgent 5}
upsAgentNtpTimeServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { upsAgent 6 }
upsAgentNtpTimeZone OBJECT-TYPE
SYNTAX INTEGER {
gmt1200dateLineWest(1),
gmt1200kwajalein(2),
gmt1100samoa(3),
gmt1000hawaii(4),
gmt0900alaska(5),
gmt0800tijuana(6),
gmt0700arizona(7),
gmt0700chihuahua(8),
gmt0700mountain(9),
gmt0600camerica(10),
gmt0600ctime(11),
gmt0600guadalajara(12),
gmt0600saskatchewan(13),
gmt0500quito(14),
gmt0500etime(15),
gmt0500indiana(16),
gmt0400atime(17),
gmt0400caracas(18),
gmt0400santiago(19),
gmt0330newfoundland(20),
gmt0300brasilia(21),
gmt0300georgetown(22),
gmt0300greenland(23),
gmt0200atlantic(24),
gmt0100azores(25),
gmt0100cvi(26),
gmt0000monrovia(27),
gmt0000london(28),
gmt0100vienna(29),
gmt0100prague(30),
gmt0100paris(31),
gmt0100zagreb(32),
gmt0100wcafrica(33),
gmt0200minsk(34),
gmt0200bucharest(35),
gmt0200cairo(36),
gmt0200pretoria(37),
gmt0200vilnius(38),
gmt0200jerusalem(39),
gmt0300maghdad(40),
gmt0300riyadh(41),
gmt0300volgograd(42),
gmt0300nairobi(43),
gmt0330tehran(44),
gmt0400muscat(45),
gmt0400yerevan(46),
gmt0430kabul(47),
gmt0500ekaterinburg(48),
gmt0500tashkent(49),
gmt0530calcutta(50),
gmt0530mumbai(51),
gmt0545kathmandu(52),
gmt0600novosibirsk(53),
gmt0600dhaka(54),
gmt0600jayawardenepura(55),
gmt0630rangoon(56),
gmt0700bangkok(57),
gmt0700krasnoyarsk(58),
gmt0800beijing(59),
gmt0800irkutsk(60),
gmt0800singapore(61),
gmt0800perth(62),
gmt0800taipei(63),
gmt0900tokyo(64),
gmt0900seoul(65),
gmt0900yakutsk(66),
gmt0930adelaide(67),
gmt0930darwin(68),
gmt1000brisbane(69),
gmt1000canberra(70),
gmt1000guam(71),
gmt1000hobart(72),
gmt1000vladivostok(73),
gmt1100magadan(74),
gmt1200auckland(75),
gmt1200fiji(76),
gmt1300alofa(77)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { upsAgent 7 }
upsAgentHistoryLogFrequency OBJECT-TYPE
SYNTAX INTEGER (5..28800) -- in seconds
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The frequency of the updation of the history log. The value
is in seconds"
::= { upsAgent 8 }
upsAgentExtHistoryLogFrequency OBJECT-TYPE
SYNTAX INTEGER (3..10080) -- in minutes
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ups parameters are sampled at the rate governed by the
mconfigHistroyLogFrequency. These sampled values are further
conslidated over period of time which is determined by this
object."
::= { upsAgent 9 }
upsAgentPollRate OBJECT-TYPE
SYNTAX INTEGER (3..999) -- in seconds
ACCESS read-write
STATUS mandatory
DESCRIPTION
" The frequency that proxy agent polls the connected
UPS in JBUS protocol. (unit : second)"
::= { upsAgent 10}
upsAgentBaudRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial port communication speed. only 9600 allowed"
::= { upsAgent 11}
upsAgentDhcpStatue OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable DHCP/BootP capability"
::= { upsAgent 12}
upsAgentTelnetStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable telnet access"
::= { upsAgent 13}
upsAgentTftpStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable network upgrade capability"
::= { upsAgent 14}
upsAgentResetToDefault OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all parameters of Net Vision to default value"
::= { upsAgent 15}
upsAgentRestart OBJECT-TYPE
SYNTAX INTEGER {
restart(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Restart Net Vision"
::= { upsAgent 16}
upsAgentClearAgentLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear agent log data"
::= { upsAgent 17}
upsAgentClearEventLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear event log data"
::= { upsAgent 18}
upsAgentClearExtHistoryLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear extented history log data"
::= { upsAgent 19}
upsAgentClearHistoryLog OBJECT-TYPE
SYNTAX INTEGER {
clear(1),
nothing(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clear history log data"
::= { upsAgent 20}
upsAgentTrapsReceiversTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsAgentTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers to send traps to. The number of
entries is given by the value of upsAgentNumTrapReceivers"
::= { upsAgent 21}
upsAgentTrapsReceiversEntry OBJECT-TYPE
SYNTAX UpsAgentTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers to send traps to."
INDEX { trapsIndex}
::= { upsAgentTrapsReceiversTable 1 }
UpsAgentTrapsReceiversEntry ::= SEQUENCE{
trapsIndex
INTEGER,
trapsReceiverAddr
DisplayString,
receiverCommunityString
DisplayString,
receiverNmstype
INTEGER
-- receiverDescription
-- DisplayString
}
trapsIndex OBJECT-TYPE
SYNTAX INTEGER(1..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a trap receiver entry."
::= { upsAgentTrapsReceiversEntry 1 }
trapsReceiverAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the manager to send a trap to."
::= { upsAgentTrapsReceiversEntry 2 }
receiverCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The community name to use in the trap when sent to the manager."
::= { upsAgentTrapsReceiversEntry 3 }
receiverNmstype OBJECT-TYPE
SYNTAX INTEGER {
none(1),
rfc1628-trap(2),
netVision-trap(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trap group that NMS desired."
::= { upsAgentTrapsReceiversEntry 4 }
--receiverDescription OBJECT-TYPE
-- SYNTAX DisplayString (SIZE(0..31))
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Description of trap receivers"
-- ::= { upsAgentTrapsReceiversEntry 5 }
upsAgentFirewallControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsAgentFirewallControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers which can access Net Vision with private
community string."
::= { upsAgent 22}
upsAgentFirewallControlEntry OBJECT-TYPE
SYNTAX UpsAgentFirewallControlEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers."
INDEX { trapsIndex}
::= { upsAgentFirewallControlTable 1 }
UpsAgentFirewallControlEntry ::= SEQUENCE {
firewallIndex INTEGER,
firewallControlAddr DisplayString,
firewallPrefixLength INTEGER,
firewallActionMode INTEGER
}
firewallIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a firewall entry."
::= { upsAgentFirewallControlEntry 1 }
firewallControlAddr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the firewall "
::= { upsAgentFirewallControlEntry 2 }
firewallPrefixLength OBJECT-TYPE
SYNTAX INTEGER (1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The firewall prefix length."
::= { upsAgentFirewallControlEntry 3 }
firewallActionMode OBJECT-TYPE
SYNTAX INTEGER {
accept (1),
reject (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The firewall action mode"
::= { upsAgentFirewallControlEntry 4 }
upsAgentMibVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of MIB spec."
::= { upsAgent 23 }
-- ===========================================================================
--
-- emdStatus
--
-- ===========================================================================
emdSatatusTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measurement of EMD temperature, in 0.1 degree"
::= { emdStatus 1}
emdSatatusHumidity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measurement of EMD humidity, in 0.1 degree"
::= { emdStatus 2}
emdStatusIn1Active OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
notActived(2),
actived(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input 1 has been detected as Active"
::= { emdStatus 3}
emdStatusIn2Active OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
notActived(2),
actived(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The input 2 has been detected as Active"
::= { emdStatus 4}
-- ===========================================================================
-- upsTraps
--
-- Traps group
-- ===========================================================================
-- This section defines the well-known notifications sent by
-- UPS agents.
-- Care must be taken to insure that no particular notification
-- is sent to a single receiving entity more often than once
-- every five seconds.
upsTrapOnBattery TRAP-TYPE
ENTERPRISE upsTraps
VARIABLES { upsEstimatedMinutesRemaining, upsSecondsOnBattery }
DESCRIPTION
"WARNING:The UPS is operating on battery power. This trap is
persistent and is resent at one minute intervals until
the UPS either turns off or is no longer running on
battery."
::= 1
upsTrapTestCompleted TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION:This trap is sent upon completion of a UPS diagnostic
test."
::= 2
upsTrapAlarmEntryAdded TRAP-TYPE
ENTERPRISE upsTraps
VARIABLES { upsAlarmId, upsAlarmDescr }
DESCRIPTION
"WARNING:This trap is sent each time an alarm is inserted into
to the alarm table. It is sent on the insertion of
all alarms except for upsAlarmOnBattery and
upsAlarmTestInProgress."
::= 3
upsTrapAlarmEntryRemoved TRAP-TYPE
ENTERPRISE upsTraps
VARIABLES { upsAlarmId, upsAlarmDescr }
DESCRIPTION
"INFORMATION:This trap is sent each time an alarm is removed from
the alarm table. It is sent on the removal of all
alarms except for upsAlarmTestInProgress."
::= 4
upsTrapImminentStop TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The UPS is near to switch off the output power."
::= 5
upsTrapOverload TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: The UPS output is in overload. Output load rate more than 100%"
::= 6
upsTrapRedundancyLost TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: Redundancy is lost."
::= 7
upsTrapBatteryCircuitOpen TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The battery has been disconnected from UPS"
::= 8
upsTrapBatteryDischarged TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The battery has been detected as discharged."
::= 9
upsTrapBatteryLow TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The battery is near of the end of backup time."
::= 10
upsTrapBatteryAlarm TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: The battery is in alarm."
::= 11
upsTrapUpsCriticalAlarm TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: A critical alarm has been detected on the UPS."
::= 12
upsTrapLoadOFF TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The load has been disconnected from the UPS. LOAD OFF."
::= 13
upsTrapCommunicationLost TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: UPS is no more communicating with the agent."
::= 14
upsTrapOnBatteryPower TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: The UPS has switched to battery backup power."
::= 15
upsTrapBatteryTestfailed TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: The Battery test has detected a weak battery."
::= 16
upsTrapTemperatureAlarm TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: The UPS internal temperature has reached the threshold."
::= 17
upsTrapOnBypass TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: Load supplied by automatic Bypass."
::= 18
upsTrapUpsPreventiveAlarm TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: A preventive alarm has been detected by the UPS."
::= 19
upsTrapShutdownWarning TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: A warning message has be sent to shutdown agent."
::= 20
upsTrapShutdownrequest TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"WARNING: A shutdown command has been sent to agent."
::= 21
upsTrapUpsNormal TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The UPS status is normal. Load protected by UPS"
::= 22
upsTrapPowerRestored TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The Input supply has been restored"
::= 23
upsTrapAlarmCancelled TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: Alarm cancelled. All alarms are disabled"
::= 24
upsTrapComEstablished TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The communication between UPS and the agent has been restored"
::= 25
upsTrapShutdwonCancelled TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The UPS has cancelled the shutdown procedure to agent"
::= 26
upsTrapAgentRestarting TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: NET VISION is restarting"
::= 27
upsTrapEmdTempLow TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: EMD Sensor detected low temperature."
::= 28
upsTrapEmdTempNotLow TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: EMD Sensor Not under low temperature."
::= 29
upsTrapEmdTempHigh TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: EMD Sensor detected high temperature."
::= 30
upsTrapEmdTempNotHigh TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: EMD Sensor Not over high temperature."
::= 31
upsTrapEmdHumidityLow TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: EMD Sensor detected low humidity."
::= 32
upsTrapEmdHumidityNotLow TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: EMD Sensor Not under low humidity."
::= 33
upsTrapEmdHumidityHigh TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: EMD Sensor detected high humidity."
::= 34
upsTrapEmdHumidityNotHigh TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: EMD Sensor Not over high humidity."
::= 35
upsTrapEmdFirstInputActive TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The <customized> input is active."
::= 36
upsTrapEmdFirstInputRestored TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The <customized> input is restored."
::= 37
upsTrapEmdSecondInputActive TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"CRITICAL: The <customized> input is active."
::= 38
upsTrapEmdSecondInputRestored TRAP-TYPE
ENTERPRISE upsTraps
DESCRIPTION
"INFORMATION: The <customized> input is restored."
::= 39
END