- LibreNMS Discovery
- ===================================
- Version info:
- Commit SHA: 2370072a14e37ee34adb64de37e6e3bb5b2fd43e
- Commit Date: 1512765269
- DB Schema: 222
- PHP: 7.1.11
- MySQL: 5.5.56-MariaDB
- RRDTool: 1.4.8
- SNMP: NET-SNMP 5.7.2
- ==================================DEBUG!
- SQL[[0;33mSELECT * FROM `devices` WHERE disabled = 0 AND snmp_disable = 0 AND `hostname` LIKE '172.16.239.230' ORDER BY device_id DESC[0m]
- SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '10'[0m]
- 172.16.239.230 10 hpe-msa SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES ('4','4','0','0.49','1.43','0.75','10',NOW())[0m]
- SNMP Check response code: 0
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '10' AND `attrib_type` = 'poll_mib' [0m]
- Modules status: Global+ OS+ Device
- #### Load disco module sensors ####
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsbe -Ih -m FCMGMT-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 connUnitSensorTable[0m]
- connUnitSensorUnitId.*.*.*.*.1 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.2 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.3 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.4 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.5 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.6 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.7 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.8 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.9 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.10 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.11 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.12 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.13 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.14 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.15 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.16 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.17 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.18 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.19 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.20 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.21 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.22 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.23 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.24 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.25 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.26 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.27 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.28 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.29 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.30 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.31 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.32 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.33 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.34 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.35 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.36 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.37 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.38 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.39 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.40 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.41 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.42 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.43 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.44 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.45 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.46 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorUnitId.*.*.*.*.47 = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitSensorIndex.*.*.*.*.1 = 1
- connUnitSensorIndex.*.*.*.*.2 = 2
- connUnitSensorIndex.*.*.*.*.3 = 3
- connUnitSensorIndex.*.*.*.*.4 = 4
- connUnitSensorIndex.*.*.*.*.5 = 5
- connUnitSensorIndex.*.*.*.*.6 = 6
- connUnitSensorIndex.*.*.*.*.7 = 7
- connUnitSensorIndex.*.*.*.*.8 = 8
- connUnitSensorIndex.*.*.*.*.9 = 9
- connUnitSensorIndex.*.*.*.*.10 = 10
- connUnitSensorIndex.*.*.*.*.11 = 11
- connUnitSensorIndex.*.*.*.*.12 = 12
- connUnitSensorIndex.*.*.*.*.13 = 13
- connUnitSensorIndex.*.*.*.*.14 = 14
- connUnitSensorIndex.*.*.*.*.15 = 15
- connUnitSensorIndex.*.*.*.*.16 = 16
- connUnitSensorIndex.*.*.*.*.17 = 17
- connUnitSensorIndex.*.*.*.*.18 = 18
- connUnitSensorIndex.*.*.*.*.19 = 19
- connUnitSensorIndex.*.*.*.*.20 = 20
- connUnitSensorIndex.*.*.*.*.21 = 21
- connUnitSensorIndex.*.*.*.*.22 = 22
- connUnitSensorIndex.*.*.*.*.23 = 23
- connUnitSensorIndex.*.*.*.*.24 = 24
- connUnitSensorIndex.*.*.*.*.25 = 25
- connUnitSensorIndex.*.*.*.*.26 = 26
- connUnitSensorIndex.*.*.*.*.27 = 27
- connUnitSensorIndex.*.*.*.*.28 = 28
- connUnitSensorIndex.*.*.*.*.29 = 29
- connUnitSensorIndex.*.*.*.*.30 = 30
- connUnitSensorIndex.*.*.*.*.31 = 31
- connUnitSensorIndex.*.*.*.*.32 = 32
- connUnitSensorIndex.*.*.*.*.33 = 33
- connUnitSensorIndex.*.*.*.*.34 = 34
- connUnitSensorIndex.*.*.*.*.35 = 35
- connUnitSensorIndex.*.*.*.*.36 = 36
- connUnitSensorIndex.*.*.*.*.37 = 37
- connUnitSensorIndex.*.*.*.*.38 = 38
- connUnitSensorIndex.*.*.*.*.39 = 39
- connUnitSensorIndex.*.*.*.*.40 = 40
- connUnitSensorIndex.*.*.*.*.41 = 41
- connUnitSensorIndex.*.*.*.*.42 = 42
- connUnitSensorIndex.*.*.*.*.43 = 43
- connUnitSensorIndex.*.*.*.*.44 = 44
- connUnitSensorIndex.*.*.*.*.45 = 45
- connUnitSensorIndex.*.*.*.*.46 = 46
- connUnitSensorIndex.*.*.*.*.47 = 47
- connUnitSensorName.*.*.*.*.1 = "On-Board Temperature 1-Ctlr A"
- connUnitSensorName.*.*.*.*.2 = "On-Board Temperature 1-Ctlr B"
- connUnitSensorName.*.*.*.*.3 = "On-Board Temperature 2-Ctlr A"
- connUnitSensorName.*.*.*.*.4 = "On-Board Temperature 2-Ctlr B"
- connUnitSensorName.*.*.*.*.5 = "On-Board Temperature 3-Ctlr A"
- connUnitSensorName.*.*.*.*.6 = "On-Board Temperature 3-Ctlr B"
- connUnitSensorName.*.*.*.*.7 = "Disk Controller Temp-Ctlr A"
- connUnitSensorName.*.*.*.*.8 = "Disk Controller Temp-Ctlr B"
- connUnitSensorName.*.*.*.*.9 = "Memory Controller Temp-Ctlr A"
- connUnitSensorName.*.*.*.*.10 = "Memory Controller Temp-Ctlr B"
- connUnitSensorName.*.*.*.*.11 = "Capacitor Pack Voltage-Ctlr A"
- connUnitSensorName.*.*.*.*.12 = "Capacitor Pack Voltage-Ctlr B"
- connUnitSensorName.*.*.*.*.13 = "Capacitor Cell 1 Voltage-Ctlr A"
- connUnitSensorName.*.*.*.*.14 = "Capacitor Cell 1 Voltage-Ctlr B"
- connUnitSensorName.*.*.*.*.15 = "Capacitor Cell 2 Voltage-Ctlr A"
- connUnitSensorName.*.*.*.*.16 = "Capacitor Cell 2 Voltage-Ctlr B"
- connUnitSensorName.*.*.*.*.17 = "Capacitor Cell 3 Voltage-Ctlr A"
- connUnitSensorName.*.*.*.*.18 = "Capacitor Cell 3 Voltage-Ctlr B"
- connUnitSensorName.*.*.*.*.19 = "Capacitor Cell 4 Voltage-Ctlr A"
- connUnitSensorName.*.*.*.*.20 = "Capacitor Cell 4 Voltage-Ctlr B"
- connUnitSensorName.*.*.*.*.21 = "Capacitor Charge-Ctlr A"
- connUnitSensorName.*.*.*.*.22 = "Capacitor Charge-Ctlr B"
- connUnitSensorName.*.*.*.*.23 = "Overall Unit Status"
- connUnitSensorName.*.*.*.*.24 = "Temperature Loc: upper-IOM A"
- connUnitSensorName.*.*.*.*.25 = "Temperature Loc: lower-IOM B"
- connUnitSensorName.*.*.*.*.26 = "Temperature Loc: left-PSU"
- connUnitSensorName.*.*.*.*.27 = "Temperature Loc: right-PSU"
- connUnitSensorName.*.*.*.*.28 = "Voltage 12V Loc: upper-IOM A"
- connUnitSensorName.*.*.*.*.29 = "Voltage 5V Loc: upper-IOM A"
- connUnitSensorName.*.*.*.*.30 = "Voltage 12V Loc: lower-IOM B"
- connUnitSensorName.*.*.*.*.31 = "Voltage 5V Loc: lower-IOM B"
- connUnitSensorName.*.*.*.*.32 = "Voltage 12V Loc: left-PSU"
- connUnitSensorName.*.*.*.*.33 = "Voltage 5V Loc: left-PSU"
- connUnitSensorName.*.*.*.*.34 = "Voltage 3.3V Loc: left-PSU"
- connUnitSensorName.*.*.*.*.35 = "Voltage 12V Loc: right-PSU"
- connUnitSensorName.*.*.*.*.36 = "Voltage 5V Loc: right-PSU"
- connUnitSensorName.*.*.*.*.37 = "Voltage 3.3V Loc: right-PSU"
- connUnitSensorName.*.*.*.*.38 = "Current 12V Loc: upper-IOM A"
- connUnitSensorName.*.*.*.*.39 = "Current 12V Loc: lower-IOM B"
- connUnitSensorName.*.*.*.*.40 = "Current 12V Loc: left-PSU"
- connUnitSensorName.*.*.*.*.41 = "Current 5V Loc: left-PSU"
- connUnitSensorName.*.*.*.*.42 = "Current 12V Loc: right-PSU"
- connUnitSensorName.*.*.*.*.43 = "Current 5V Loc: right-PSU"
- connUnitSensorName.*.*.*.*.44 = "Temperature Loc: upper-IOM A"
- connUnitSensorName.*.*.*.*.45 = "Temperature Loc: lower-IOM B"
- connUnitSensorName.*.*.*.*.46 = "Temperature Loc: left-PSU"
- connUnitSensorName.*.*.*.*.47 = "Temperature Loc: right-PSU"
- connUnitSensorStatus.*.*.*.*.1 = 3
- connUnitSensorStatus.*.*.*.*.2 = 3
- connUnitSensorStatus.*.*.*.*.3 = 3
- connUnitSensorStatus.*.*.*.*.4 = 3
- connUnitSensorStatus.*.*.*.*.5 = 3
- connUnitSensorStatus.*.*.*.*.6 = 3
- connUnitSensorStatus.*.*.*.*.7 = 3
- connUnitSensorStatus.*.*.*.*.8 = 3
- connUnitSensorStatus.*.*.*.*.9 = 3
- connUnitSensorStatus.*.*.*.*.10 = 3
- connUnitSensorStatus.*.*.*.*.11 = 3
- connUnitSensorStatus.*.*.*.*.12 = 3
- connUnitSensorStatus.*.*.*.*.13 = 3
- connUnitSensorStatus.*.*.*.*.14 = 3
- connUnitSensorStatus.*.*.*.*.15 = 3
- connUnitSensorStatus.*.*.*.*.16 = 3
- connUnitSensorStatus.*.*.*.*.17 = 3
- connUnitSensorStatus.*.*.*.*.18 = 3
- connUnitSensorStatus.*.*.*.*.19 = 3
- connUnitSensorStatus.*.*.*.*.20 = 3
- connUnitSensorStatus.*.*.*.*.21 = 3
- connUnitSensorStatus.*.*.*.*.22 = 3
- connUnitSensorStatus.*.*.*.*.23 = 3
- connUnitSensorStatus.*.*.*.*.24 = 3
- connUnitSensorStatus.*.*.*.*.25 = 3
- connUnitSensorStatus.*.*.*.*.26 = 3
- connUnitSensorStatus.*.*.*.*.27 = 3
- connUnitSensorStatus.*.*.*.*.28 = 3
- connUnitSensorStatus.*.*.*.*.29 = 3
- connUnitSensorStatus.*.*.*.*.30 = 3
- connUnitSensorStatus.*.*.*.*.31 = 3
- connUnitSensorStatus.*.*.*.*.32 = 3
- connUnitSensorStatus.*.*.*.*.33 = 3
- connUnitSensorStatus.*.*.*.*.34 = 3
- connUnitSensorStatus.*.*.*.*.35 = 3
- connUnitSensorStatus.*.*.*.*.36 = 3
- connUnitSensorStatus.*.*.*.*.37 = 3
- connUnitSensorStatus.*.*.*.*.38 = 3
- connUnitSensorStatus.*.*.*.*.39 = 3
- connUnitSensorStatus.*.*.*.*.40 = 3
- connUnitSensorStatus.*.*.*.*.41 = 3
- connUnitSensorStatus.*.*.*.*.42 = 3
- connUnitSensorStatus.*.*.*.*.43 = 3
- connUnitSensorStatus.*.*.*.*.44 = 3
- connUnitSensorStatus.*.*.*.*.45 = 3
- connUnitSensorStatus.*.*.*.*.46 = 3
- connUnitSensorStatus.*.*.*.*.47 = 3
- connUnitSensorInfo.*.*.*.*.1 = ""
- connUnitSensorInfo.*.*.*.*.2 = ""
- connUnitSensorInfo.*.*.*.*.3 = ""
- connUnitSensorInfo.*.*.*.*.4 = ""
- connUnitSensorInfo.*.*.*.*.5 = ""
- connUnitSensorInfo.*.*.*.*.6 = ""
- connUnitSensorInfo.*.*.*.*.7 = ""
- connUnitSensorInfo.*.*.*.*.8 = ""
- connUnitSensorInfo.*.*.*.*.9 = ""
- connUnitSensorInfo.*.*.*.*.10 = ""
- connUnitSensorInfo.*.*.*.*.11 = ""
- connUnitSensorInfo.*.*.*.*.12 = ""
- connUnitSensorInfo.*.*.*.*.13 = ""
- connUnitSensorInfo.*.*.*.*.14 = ""
- connUnitSensorInfo.*.*.*.*.15 = ""
- connUnitSensorInfo.*.*.*.*.16 = ""
- connUnitSensorInfo.*.*.*.*.17 = ""
- connUnitSensorInfo.*.*.*.*.18 = ""
- connUnitSensorInfo.*.*.*.*.19 = ""
- connUnitSensorInfo.*.*.*.*.20 = ""
- connUnitSensorInfo.*.*.*.*.21 = ""
- connUnitSensorInfo.*.*.*.*.22 = ""
- connUnitSensorInfo.*.*.*.*.23 = ""
- connUnitSensorInfo.*.*.*.*.24 = ""
- connUnitSensorInfo.*.*.*.*.25 = ""
- connUnitSensorInfo.*.*.*.*.26 = ""
- connUnitSensorInfo.*.*.*.*.27 = ""
- connUnitSensorInfo.*.*.*.*.28 = ""
- connUnitSensorInfo.*.*.*.*.29 = ""
- connUnitSensorInfo.*.*.*.*.30 = ""
- connUnitSensorInfo.*.*.*.*.31 = ""
- connUnitSensorInfo.*.*.*.*.32 = ""
- connUnitSensorInfo.*.*.*.*.33 = ""
- connUnitSensorInfo.*.*.*.*.34 = ""
- connUnitSensorInfo.*.*.*.*.35 = ""
- connUnitSensorInfo.*.*.*.*.36 = ""
- connUnitSensorInfo.*.*.*.*.37 = ""
- connUnitSensorInfo.*.*.*.*.38 = ""
- connUnitSensorInfo.*.*.*.*.39 = ""
- connUnitSensorInfo.*.*.*.*.40 = ""
- connUnitSensorInfo.*.*.*.*.41 = ""
- connUnitSensorInfo.*.*.*.*.42 = ""
- connUnitSensorInfo.*.*.*.*.43 = ""
- connUnitSensorInfo.*.*.*.*.44 = ""
- connUnitSensorInfo.*.*.*.*.45 = ""
- connUnitSensorInfo.*.*.*.*.46 = ""
- connUnitSensorInfo.*.*.*.*.47 = ""
- connUnitSensorMessage.*.*.*.*.1 = "On-Board Temperature 1-Ctlr A: 45 C 113.00F"
- connUnitSensorMessage.*.*.*.*.2 = "On-Board Temperature 1-Ctlr B: 44 C 111.20F"
- connUnitSensorMessage.*.*.*.*.3 = "On-Board Temperature 2-Ctlr A: 67 C 152.60F"
- connUnitSensorMessage.*.*.*.*.4 = "On-Board Temperature 2-Ctlr B: 58 C 136.40F"
- connUnitSensorMessage.*.*.*.*.5 = "On-Board Temperature 3-Ctlr A: 45 C 113.00F"
- connUnitSensorMessage.*.*.*.*.6 = "On-Board Temperature 3-Ctlr B: 43 C 109.40F"
- connUnitSensorMessage.*.*.*.*.7 = "Disk Controller Temp-Ctlr A: 27 C 80.60F"
- connUnitSensorMessage.*.*.*.*.8 = "Disk Controller Temp-Ctlr B: 27 C 80.60F"
- connUnitSensorMessage.*.*.*.*.9 = "Memory Controller Temp-Ctlr A: 61 C 141.80F"
- connUnitSensorMessage.*.*.*.*.10 = "Memory Controller Temp-Ctlr B: 62 C 143.60F"
- connUnitSensorMessage.*.*.*.*.11 = "Capacitor Pack Voltage-Ctlr A: 8.22V"
- connUnitSensorMessage.*.*.*.*.12 = "Capacitor Pack Voltage-Ctlr B: 8.19V"
- connUnitSensorMessage.*.*.*.*.13 = "Capacitor Cell 1 Voltage-Ctlr A: 2.04V"
- connUnitSensorMessage.*.*.*.*.14 = "Capacitor Cell 1 Voltage-Ctlr B: 2.05V"
- connUnitSensorMessage.*.*.*.*.15 = "Capacitor Cell 2 Voltage-Ctlr A: 2.07V"
- connUnitSensorMessage.*.*.*.*.16 = "Capacitor Cell 2 Voltage-Ctlr B: 2.07V"
- connUnitSensorMessage.*.*.*.*.17 = "Capacitor Cell 3 Voltage-Ctlr A: 2.03V"
- connUnitSensorMessage.*.*.*.*.18 = "Capacitor Cell 3 Voltage-Ctlr B: 2.02V"
- connUnitSensorMessage.*.*.*.*.19 = "Capacitor Cell 4 Voltage-Ctlr A: 2.09V"
- connUnitSensorMessage.*.*.*.*.20 = "Capacitor Cell 4 Voltage-Ctlr B: 2.06V"
- connUnitSensorMessage.*.*.*.*.21 = "Capacitor Charge-Ctlr A: 95%"
- connUnitSensorMessage.*.*.*.*.22 = "Capacitor Charge-Ctlr B: 100%"
- connUnitSensorMessage.*.*.*.*.23 = "Overall Unit Status: OK"
- connUnitSensorMessage.*.*.*.*.24 = "Temperature Loc: upper-IOM A: 33 C 91.40F"
- connUnitSensorMessage.*.*.*.*.25 = "Temperature Loc: lower-IOM B: 31 C 87.80F"
- connUnitSensorMessage.*.*.*.*.26 = "Temperature Loc: left-PSU: 31 C 87.80F"
- connUnitSensorMessage.*.*.*.*.27 = "Temperature Loc: right-PSU: 31 C 87.80F"
- connUnitSensorMessage.*.*.*.*.28 = "Voltage 12V Loc: upper-IOM A: 11.81V"
- connUnitSensorMessage.*.*.*.*.29 = "Voltage 5V Loc: upper-IOM A: 5.01V"
- connUnitSensorMessage.*.*.*.*.30 = "Voltage 12V Loc: lower-IOM B: 11.81V"
- connUnitSensorMessage.*.*.*.*.31 = "Voltage 5V Loc: lower-IOM B: 5.05V"
- connUnitSensorMessage.*.*.*.*.32 = "Voltage 12V Loc: left-PSU: 11.95V"
- connUnitSensorMessage.*.*.*.*.33 = "Voltage 5V Loc: left-PSU: 5.06V"
- connUnitSensorMessage.*.*.*.*.34 = "Voltage 3.3V Loc: left-PSU: 3.40V"
- connUnitSensorMessage.*.*.*.*.35 = "Voltage 12V Loc: right-PSU: 11.95V"
- connUnitSensorMessage.*.*.*.*.36 = "Voltage 5V Loc: right-PSU: 5.06V"
- connUnitSensorMessage.*.*.*.*.37 = "Voltage 3.3V Loc: right-PSU: 3.39V"
- connUnitSensorMessage.*.*.*.*.38 = "Current 12V Loc: upper-IOM A: 5.30A"
- connUnitSensorMessage.*.*.*.*.39 = "Current 12V Loc: lower-IOM B: 5.24A"
- connUnitSensorMessage.*.*.*.*.40 = "Current 12V Loc: left-PSU: 6.20A"
- connUnitSensorMessage.*.*.*.*.41 = "Current 5V Loc: left-PSU: 6.57A"
- connUnitSensorMessage.*.*.*.*.42 = "Current 12V Loc: right-PSU: 9.26A"
- connUnitSensorMessage.*.*.*.*.43 = "Current 5V Loc: right-PSU: 5.98A"
- connUnitSensorMessage.*.*.*.*.44 = "Temperature Loc: upper-IOM A: 44 C 111.20F"
- connUnitSensorMessage.*.*.*.*.45 = "Temperature Loc: lower-IOM B: 44 C 111.20F"
- connUnitSensorMessage.*.*.*.*.46 = "Temperature Loc: left-PSU: 29 C 84.20F"
- connUnitSensorMessage.*.*.*.*.47 = "Temperature Loc: right-PSU: 29 C 84.20F"
- connUnitSensorType.*.*.*.*.1 = 8
- connUnitSensorType.*.*.*.*.2 = 8
- connUnitSensorType.*.*.*.*.3 = 8
- connUnitSensorType.*.*.*.*.4 = 8
- connUnitSensorType.*.*.*.*.5 = 8
- connUnitSensorType.*.*.*.*.6 = 8
- connUnitSensorType.*.*.*.*.7 = 8
- connUnitSensorType.*.*.*.*.8 = 8
- connUnitSensorType.*.*.*.*.9 = 8
- connUnitSensorType.*.*.*.*.10 = 8
- connUnitSensorType.*.*.*.*.11 = 8
- connUnitSensorType.*.*.*.*.12 = 8
- connUnitSensorType.*.*.*.*.13 = 8
- connUnitSensorType.*.*.*.*.14 = 8
- connUnitSensorType.*.*.*.*.15 = 8
- connUnitSensorType.*.*.*.*.16 = 8
- connUnitSensorType.*.*.*.*.17 = 8
- connUnitSensorType.*.*.*.*.18 = 8
- connUnitSensorType.*.*.*.*.19 = 8
- connUnitSensorType.*.*.*.*.20 = 8
- connUnitSensorType.*.*.*.*.21 = 8
- connUnitSensorType.*.*.*.*.22 = 8
- connUnitSensorType.*.*.*.*.23 = 7
- connUnitSensorType.*.*.*.*.24 = 7
- connUnitSensorType.*.*.*.*.25 = 7
- connUnitSensorType.*.*.*.*.26 = 5
- connUnitSensorType.*.*.*.*.27 = 5
- connUnitSensorType.*.*.*.*.28 = 7
- connUnitSensorType.*.*.*.*.29 = 7
- connUnitSensorType.*.*.*.*.30 = 7
- connUnitSensorType.*.*.*.*.31 = 7
- connUnitSensorType.*.*.*.*.32 = 5
- connUnitSensorType.*.*.*.*.33 = 5
- connUnitSensorType.*.*.*.*.34 = 5
- connUnitSensorType.*.*.*.*.35 = 5
- connUnitSensorType.*.*.*.*.36 = 5
- connUnitSensorType.*.*.*.*.37 = 5
- connUnitSensorType.*.*.*.*.38 = 7
- connUnitSensorType.*.*.*.*.39 = 7
- connUnitSensorType.*.*.*.*.40 = 5
- connUnitSensorType.*.*.*.*.41 = 5
- connUnitSensorType.*.*.*.*.42 = 5
- connUnitSensorType.*.*.*.*.43 = 5
- connUnitSensorType.*.*.*.*.44 = 7
- connUnitSensorType.*.*.*.*.45 = 7
- connUnitSensorType.*.*.*.*.46 = 7
- connUnitSensorType.*.*.*.*.47 = 7
- connUnitSensorCharacteristic.*.*.*.*.1 = 3
- connUnitSensorCharacteristic.*.*.*.*.2 = 3
- connUnitSensorCharacteristic.*.*.*.*.3 = 3
- connUnitSensorCharacteristic.*.*.*.*.4 = 3
- connUnitSensorCharacteristic.*.*.*.*.5 = 3
- connUnitSensorCharacteristic.*.*.*.*.6 = 3
- connUnitSensorCharacteristic.*.*.*.*.7 = 3
- connUnitSensorCharacteristic.*.*.*.*.8 = 3
- connUnitSensorCharacteristic.*.*.*.*.9 = 3
- connUnitSensorCharacteristic.*.*.*.*.10 = 3
- connUnitSensorCharacteristic.*.*.*.*.11 = 9
- connUnitSensorCharacteristic.*.*.*.*.12 = 9
- connUnitSensorCharacteristic.*.*.*.*.13 = 9
- connUnitSensorCharacteristic.*.*.*.*.14 = 9
- connUnitSensorCharacteristic.*.*.*.*.15 = 9
- connUnitSensorCharacteristic.*.*.*.*.16 = 9
- connUnitSensorCharacteristic.*.*.*.*.17 = 9
- connUnitSensorCharacteristic.*.*.*.*.18 = 9
- connUnitSensorCharacteristic.*.*.*.*.19 = 9
- connUnitSensorCharacteristic.*.*.*.*.20 = 9
- connUnitSensorCharacteristic.*.*.*.*.21 = 2
- connUnitSensorCharacteristic.*.*.*.*.22 = 2
- connUnitSensorCharacteristic.*.*.*.*.23 = 2
- connUnitSensorCharacteristic.*.*.*.*.24 = 3
- connUnitSensorCharacteristic.*.*.*.*.25 = 3
- connUnitSensorCharacteristic.*.*.*.*.26 = 3
- connUnitSensorCharacteristic.*.*.*.*.27 = 3
- connUnitSensorCharacteristic.*.*.*.*.28 = 9
- connUnitSensorCharacteristic.*.*.*.*.29 = 9
- connUnitSensorCharacteristic.*.*.*.*.30 = 9
- connUnitSensorCharacteristic.*.*.*.*.31 = 9
- connUnitSensorCharacteristic.*.*.*.*.32 = 9
- connUnitSensorCharacteristic.*.*.*.*.33 = 9
- connUnitSensorCharacteristic.*.*.*.*.34 = 9
- connUnitSensorCharacteristic.*.*.*.*.35 = 9
- connUnitSensorCharacteristic.*.*.*.*.36 = 9
- connUnitSensorCharacteristic.*.*.*.*.37 = 9
- connUnitSensorCharacteristic.*.*.*.*.38 = 6
- connUnitSensorCharacteristic.*.*.*.*.39 = 6
- connUnitSensorCharacteristic.*.*.*.*.40 = 6
- connUnitSensorCharacteristic.*.*.*.*.41 = 6
- connUnitSensorCharacteristic.*.*.*.*.42 = 6
- connUnitSensorCharacteristic.*.*.*.*.43 = 6
- connUnitSensorCharacteristic.*.*.*.*.44 = 3
- connUnitSensorCharacteristic.*.*.*.*.45 = 3
- connUnitSensorCharacteristic.*.*.*.*.46 = 3
- connUnitSensorCharacteristic.*.*.*.*.47 = 3
- SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsbe -Ih -m FCMGMT-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 connUnitTable[0m]
- connUnitId.*.*.*.* = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitGlobalId.*.*.*.* = "20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00 "
- connUnitType.*.*.*.* = 11
- connUnitNumports.*.*.*.* = 8
- connUnitState.*.*.*.* = 2
- connUnitStatus.*.*.*.* = 3
- connUnitProduct.*.*.*.* = "HP StorageWorks P2000 G3 iSCSI"
- connUnitSn.*.*.*.* = "2S6124C006"
- connUnitUpTime.*.*.*.* = 175:2:15:08.02
- connUnitUrl.*.*.*.* = "http:*"
- connUnitDomainId.*.*.*.* = "FF FF FF "
- connUnitProxyMaster.*.*.*.* = 3
- connUnitPrincipal.*.*.*.* = 1
- connUnitNumSensors.*.*.*.* = 47
- connUnitStatusChangeTime.*.*.*.* = 175:2:15:08.02
- connUnitConfigurationChangeTime.*.*.*.* = 175:2:15:08.02
- connUnitNumRevs.*.*.*.* = 36
- connUnitNumZones.*.*.*.* = 0
- connUnitModuleId.*.*.*.* = "00 "
- connUnitName.*.*.*.* = "nb-vmmsa"
- connUnitInfo.*.*.*.* = "582939-001"
- connUnitControl.*.*.*.* = 2
- connUnitContact.*.*.*.* = "System Admin paging@nbisd.org"
- connUnitLocation.*.*.*.* = "EC NOC"
- connUnitEventFilter.*.*.*.* = 8
- connUnitNumEvents.*.*.*.* = 40
- connUnitMaxEvents.*.*.*.* = 40
- connUnitEventCurrID.*.*.*.* = 0
- ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 entPhysicalDescr[0m]
- entPhysicalDescr = No Such Object available on this agent at this OID
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '10' AND `attrib_type` = 'ipmi_hostname' [0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'ipmi'[0m]
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'ipmi'[0m]
- Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- State: Dynamic Discovery (state): Array
- (
- [data] => Array
- (
- [0] => Array
- (
- [oid] => connUnitSensorTable
- [value] => connUnitSensorStatus
- [num_oid] => .1.3.6.1.3.94.1.8.1.4.
- [descr] => connUnitSensorName
- [index] => connUnitSensorStatus.{{ $index }}
- [snmp_flags] => -OQUsbe
- [state_name] => connUnitSensorStatus
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [generic] => 3
- [graph] => 1
- [descr] => unknown
- )
- [1] => Array
- (
- [value] => 2
- [generic] => 1
- [graph] => 1
- [descr] => other
- )
- [2] => Array
- (
- [value] => 3
- [generic] => 0
- [graph] => 1
- [descr] => ok
- )
- [3] => Array
- (
- [value] => 4
- [generic] => 1
- [graph] => 1
- [descr] => warning
- )
- [4] => Array
- (
- [value] => 5
- [generic] => 2
- [graph] => 1
- [descr] => failed
- )
- )
- )
- [1] => Array
- (
- [oid] => connUnitTable
- [value] => connUnitState
- [num_oid] => .1.3.6.1.3.94.1.6.1.5.
- [descr] => connUnitName
- [index] => connUnitState.{{ $index }}
- [snmp_flags] => -OQUsbe
- [state_name] => connUnitState
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [generic] => 3
- [graph] => 1
- [descr] => unknown
- )
- [1] => Array
- (
- [value] => 2
- [generic] => 0
- [graph] => 1
- [descr] => online
- )
- [2] => Array
- (
- [value] => 3
- [generic] => 2
- [graph] => 1
- [descr] => offline
- )
- )
- )
- [2] => Array
- (
- [oid] => connUnitTable
- [value] => connUnitStatus
- [num_oid] => .1.3.6.1.3.94.1.6.1.6.
- [descr] => connUnitName
- [index] => connUnitStatus.{{ $index }}
- [snmp_flags] => -OQUsbe
- [state_name] => connUnitStatus
- [states] => Array
- (
- [0] => Array
- (
- [value] => 1
- [generic] => 3
- [graph] => 1
- [descr] => unknown
- )
- [1] => Array
- (
- [value] => 2
- [generic] => 3
- [graph] => 1
- [descr] => unused
- )
- [2] => Array
- (
- [value] => 3
- [generic] => 0
- [graph] => 1
- [descr] => ok
- )
- [3] => Array
- (
- [value] => 4
- [generic] => 1
- [graph] => 1
- [descr] => warning
- )
- [4] => Array
- (
- [value] => 5
- [generic] => 2
- [graph] => 1
- [descr] => failed
- )
- )
- )
- )
- )
- Data connUnitSensorTable: Array
- (
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 1
- [connUnitSensorName] => On-Board Temperature 1-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 1-Ctlr A: 45 C 113.00F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 2
- [connUnitSensorName] => On-Board Temperature 1-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 1-Ctlr B: 44 C 111.20F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 3
- [connUnitSensorName] => On-Board Temperature 2-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 2-Ctlr A: 67 C 152.60F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 4
- [connUnitSensorName] => On-Board Temperature 2-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 2-Ctlr B: 58 C 136.40F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 5
- [connUnitSensorName] => On-Board Temperature 3-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 3-Ctlr A: 45 C 113.00F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 6
- [connUnitSensorName] => On-Board Temperature 3-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => On-Board Temperature 3-Ctlr B: 43 C 109.40F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 7
- [connUnitSensorName] => Disk Controller Temp-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Disk Controller Temp-Ctlr A: 27 C 80.60F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 8
- [connUnitSensorName] => Disk Controller Temp-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Disk Controller Temp-Ctlr B: 27 C 80.60F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 9
- [connUnitSensorName] => Memory Controller Temp-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Memory Controller Temp-Ctlr A: 61 C 141.80F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 10
- [connUnitSensorName] => Memory Controller Temp-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Memory Controller Temp-Ctlr B: 62 C 143.60F
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 11
- [connUnitSensorName] => Capacitor Pack Voltage-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Pack Voltage-Ctlr A: 8.22V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 12
- [connUnitSensorName] => Capacitor Pack Voltage-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Pack Voltage-Ctlr B: 8.19V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 13
- [connUnitSensorName] => Capacitor Cell 1 Voltage-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 1 Voltage-Ctlr A: 2.04V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 14
- [connUnitSensorName] => Capacitor Cell 1 Voltage-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 1 Voltage-Ctlr B: 2.05V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 15
- [connUnitSensorName] => Capacitor Cell 2 Voltage-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 2 Voltage-Ctlr A: 2.07V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 16
- [connUnitSensorName] => Capacitor Cell 2 Voltage-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 2 Voltage-Ctlr B: 2.07V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 17
- [connUnitSensorName] => Capacitor Cell 3 Voltage-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 3 Voltage-Ctlr A: 2.03V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 18
- [connUnitSensorName] => Capacitor Cell 3 Voltage-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 3 Voltage-Ctlr B: 2.02V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 19
- [connUnitSensorName] => Capacitor Cell 4 Voltage-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 4 Voltage-Ctlr A: 2.09V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 20
- [connUnitSensorName] => Capacitor Cell 4 Voltage-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Cell 4 Voltage-Ctlr B: 2.06V
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 21
- [connUnitSensorName] => Capacitor Charge-Ctlr A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Charge-Ctlr A: 95%
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 2
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 22
- [connUnitSensorName] => Capacitor Charge-Ctlr B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Capacitor Charge-Ctlr B: 100%
- [connUnitSensorType] => 8
- [connUnitSensorCharacteristic] => 2
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 23
- [connUnitSensorName] => Overall Unit Status
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Overall Unit Status: OK
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 2
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 24
- [connUnitSensorName] => Temperature Loc: upper-IOM A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: upper-IOM A: 33 C 91.40F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 25
- [connUnitSensorName] => Temperature Loc: lower-IOM B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: lower-IOM B: 31 C 87.80F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 26
- [connUnitSensorName] => Temperature Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: left-PSU: 31 C 87.80F
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 27
- [connUnitSensorName] => Temperature Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: right-PSU: 31 C 87.80F
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 28
- [connUnitSensorName] => Voltage 12V Loc: upper-IOM A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 12V Loc: upper-IOM A: 11.81V
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 29
- [connUnitSensorName] => Voltage 5V Loc: upper-IOM A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 5V Loc: upper-IOM A: 5.01V
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 30
- [connUnitSensorName] => Voltage 12V Loc: lower-IOM B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 12V Loc: lower-IOM B: 11.81V
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 31
- [connUnitSensorName] => Voltage 5V Loc: lower-IOM B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 5V Loc: lower-IOM B: 5.05V
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 32
- [connUnitSensorName] => Voltage 12V Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 12V Loc: left-PSU: 11.95V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 33
- [connUnitSensorName] => Voltage 5V Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 5V Loc: left-PSU: 5.06V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 34
- [connUnitSensorName] => Voltage 3.3V Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 3.3V Loc: left-PSU: 3.40V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 35
- [connUnitSensorName] => Voltage 12V Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 12V Loc: right-PSU: 11.95V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 36
- [connUnitSensorName] => Voltage 5V Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 5V Loc: right-PSU: 5.06V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 37
- [connUnitSensorName] => Voltage 3.3V Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Voltage 3.3V Loc: right-PSU: 3.39V
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 9
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 38
- [connUnitSensorName] => Current 12V Loc: upper-IOM A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 12V Loc: upper-IOM A: 5.30A
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 39
- [connUnitSensorName] => Current 12V Loc: lower-IOM B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 12V Loc: lower-IOM B: 5.24A
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 40
- [connUnitSensorName] => Current 12V Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 12V Loc: left-PSU: 6.20A
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 41
- [connUnitSensorName] => Current 5V Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 5V Loc: left-PSU: 6.57A
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 42
- [connUnitSensorName] => Current 12V Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 12V Loc: right-PSU: 9.26A
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 43
- [connUnitSensorName] => Current 5V Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Current 5V Loc: right-PSU: 5.98A
- [connUnitSensorType] => 5
- [connUnitSensorCharacteristic] => 6
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 44
- [connUnitSensorName] => Temperature Loc: upper-IOM A
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: upper-IOM A: 44 C 111.20F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 45
- [connUnitSensorName] => Temperature Loc: lower-IOM B
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: lower-IOM B: 44 C 111.20F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 46
- [connUnitSensorName] => Temperature Loc: left-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: left-PSU: 29 C 84.20F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47] => Array
- (
- [connUnitSensorUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitSensorIndex] => 47
- [connUnitSensorName] => Temperature Loc: right-PSU
- [connUnitSensorStatus] => 3
- [connUnitSensorInfo] =>
- [connUnitSensorMessage] => Temperature Loc: right-PSU: 29 C 84.20F
- [connUnitSensorType] => 7
- [connUnitSensorCharacteristic] => 3
- )
- )
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1, connUnitSensorStatus, On-Board Temperature 1-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1','connUnitSensorStatus','On-Board Temperature 1-Ctlr A','1','1','3')[0m]
- ( 377 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','377','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1 On-Board Temperature 1-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2, connUnitSensorStatus, On-Board Temperature 1-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2','connUnitSensorStatus','On-Board Temperature 1-Ctlr B','1','1','3')[0m]
- ( 378 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','378','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2 On-Board Temperature 1-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3, connUnitSensorStatus, On-Board Temperature 2-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3','connUnitSensorStatus','On-Board Temperature 2-Ctlr A','1','1','3')[0m]
- ( 379 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','379','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3 On-Board Temperature 2-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4, connUnitSensorStatus, On-Board Temperature 2-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4','connUnitSensorStatus','On-Board Temperature 2-Ctlr B','1','1','3')[0m]
- ( 380 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','380','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4 On-Board Temperature 2-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5, connUnitSensorStatus, On-Board Temperature 3-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5','connUnitSensorStatus','On-Board Temperature 3-Ctlr A','1','1','3')[0m]
- ( 381 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','381','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5 On-Board Temperature 3-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6, connUnitSensorStatus, On-Board Temperature 3-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6','connUnitSensorStatus','On-Board Temperature 3-Ctlr B','1','1','3')[0m]
- ( 382 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','382','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6 On-Board Temperature 3-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7, connUnitSensorStatus, Disk Controller Temp-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7','connUnitSensorStatus','Disk Controller Temp-Ctlr A','1','1','3')[0m]
- ( 383 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','383','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7 Disk Controller Temp-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8, connUnitSensorStatus, Disk Controller Temp-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8','connUnitSensorStatus','Disk Controller Temp-Ctlr B','1','1','3')[0m]
- ( 384 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','384','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8 Disk Controller Temp-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9, connUnitSensorStatus, Memory Controller Temp-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9','connUnitSensorStatus','Memory Controller Temp-Ctlr A','1','1','3')[0m]
- ( 385 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','385','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9 Memory Controller Temp-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10, connUnitSensorStatus, Memory Controller Temp-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10','connUnitSensorStatus','Memory Controller Temp-Ctlr B','1','1','3')[0m]
- ( 386 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','386','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10 Memory Controller Temp-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11, connUnitSensorStatus, Capacitor Pack Voltage-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11','connUnitSensorStatus','Capacitor Pack Voltage-Ctlr A','1','1','3')[0m]
- ( 387 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','387','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11 Capacitor Pack Voltage-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12, connUnitSensorStatus, Capacitor Pack Voltage-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12','connUnitSensorStatus','Capacitor Pack Voltage-Ctlr B','1','1','3')[0m]
- ( 388 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','388','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12 Capacitor Pack Voltage-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13, connUnitSensorStatus, Capacitor Cell 1 Voltage-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13','connUnitSensorStatus','Capacitor Cell 1 Voltage-Ctlr A','1','1','3')[0m]
- ( 389 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','389','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13 Capacitor Cell 1 Voltage-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14, connUnitSensorStatus, Capacitor Cell 1 Voltage-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14','connUnitSensorStatus','Capacitor Cell 1 Voltage-Ctlr B','1','1','3')[0m]
- ( 390 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','390','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14 Capacitor Cell 1 Voltage-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15, connUnitSensorStatus, Capacitor Cell 2 Voltage-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15','connUnitSensorStatus','Capacitor Cell 2 Voltage-Ctlr A','1','1','3')[0m]
- ( 391 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','391','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15 Capacitor Cell 2 Voltage-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16, connUnitSensorStatus, Capacitor Cell 2 Voltage-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16','connUnitSensorStatus','Capacitor Cell 2 Voltage-Ctlr B','1','1','3')[0m]
- ( 392 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','392','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16 Capacitor Cell 2 Voltage-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17, connUnitSensorStatus, Capacitor Cell 3 Voltage-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17','connUnitSensorStatus','Capacitor Cell 3 Voltage-Ctlr A','1','1','3')[0m]
- ( 393 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','393','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17 Capacitor Cell 3 Voltage-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18, connUnitSensorStatus, Capacitor Cell 3 Voltage-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18','connUnitSensorStatus','Capacitor Cell 3 Voltage-Ctlr B','1','1','3')[0m]
- ( 394 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','394','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18 Capacitor Cell 3 Voltage-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19, connUnitSensorStatus, Capacitor Cell 4 Voltage-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19','connUnitSensorStatus','Capacitor Cell 4 Voltage-Ctlr A','1','1','3')[0m]
- ( 395 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','395','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19 Capacitor Cell 4 Voltage-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20, connUnitSensorStatus, Capacitor Cell 4 Voltage-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20','connUnitSensorStatus','Capacitor Cell 4 Voltage-Ctlr B','1','1','3')[0m]
- ( 396 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','396','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20 Capacitor Cell 4 Voltage-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21, connUnitSensorStatus, Capacitor Charge-Ctlr A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21','connUnitSensorStatus','Capacitor Charge-Ctlr A','1','1','3')[0m]
- ( 397 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','397','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21 Capacitor Charge-Ctlr A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22, connUnitSensorStatus, Capacitor Charge-Ctlr B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22','connUnitSensorStatus','Capacitor Charge-Ctlr B','1','1','3')[0m]
- ( 398 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','398','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22 Capacitor Charge-Ctlr B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23, connUnitSensorStatus, Overall Unit Status, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23','connUnitSensorStatus','Overall Unit Status','1','1','3')[0m]
- ( 399 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','399','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23 Overall Unit Status','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24, connUnitSensorStatus, Temperature Loc: upper-IOM A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24','connUnitSensorStatus','Temperature Loc: upper-IOM A','1','1','3')[0m]
- ( 400 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','400','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24 Temperature Loc: upper-IOM A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25, connUnitSensorStatus, Temperature Loc: lower-IOM B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25','connUnitSensorStatus','Temperature Loc: lower-IOM B','1','1','3')[0m]
- ( 401 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','401','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25 Temperature Loc: lower-IOM B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26, connUnitSensorStatus, Temperature Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26','connUnitSensorStatus','Temperature Loc: left-PSU','1','1','3')[0m]
- ( 402 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','402','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26 Temperature Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27, connUnitSensorStatus, Temperature Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27','connUnitSensorStatus','Temperature Loc: right-PSU','1','1','3')[0m]
- ( 403 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','403','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27 Temperature Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28, connUnitSensorStatus, Voltage 12V Loc: upper-IOM A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28','connUnitSensorStatus','Voltage 12V Loc: upper-IOM A','1','1','3')[0m]
- ( 404 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','404','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28 Voltage 12V Loc: upper-IOM A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29, connUnitSensorStatus, Voltage 5V Loc: upper-IOM A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29','connUnitSensorStatus','Voltage 5V Loc: upper-IOM A','1','1','3')[0m]
- ( 405 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','405','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29 Voltage 5V Loc: upper-IOM A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30, connUnitSensorStatus, Voltage 12V Loc: lower-IOM B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30','connUnitSensorStatus','Voltage 12V Loc: lower-IOM B','1','1','3')[0m]
- ( 406 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','406','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30 Voltage 12V Loc: lower-IOM B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31, connUnitSensorStatus, Voltage 5V Loc: lower-IOM B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31','connUnitSensorStatus','Voltage 5V Loc: lower-IOM B','1','1','3')[0m]
- ( 407 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','407','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31 Voltage 5V Loc: lower-IOM B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32, connUnitSensorStatus, Voltage 12V Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32','connUnitSensorStatus','Voltage 12V Loc: left-PSU','1','1','3')[0m]
- ( 408 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','408','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32 Voltage 12V Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33, connUnitSensorStatus, Voltage 5V Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33','connUnitSensorStatus','Voltage 5V Loc: left-PSU','1','1','3')[0m]
- ( 409 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','409','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33 Voltage 5V Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34, connUnitSensorStatus, Voltage 3.3V Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34','connUnitSensorStatus','Voltage 3.3V Loc: left-PSU','1','1','3')[0m]
- ( 410 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','410','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34 Voltage 3.3V Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35, connUnitSensorStatus, Voltage 12V Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35','connUnitSensorStatus','Voltage 12V Loc: right-PSU','1','1','3')[0m]
- ( 411 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','411','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35 Voltage 12V Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36, connUnitSensorStatus, Voltage 5V Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36','connUnitSensorStatus','Voltage 5V Loc: right-PSU','1','1','3')[0m]
- ( 412 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','412','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36 Voltage 5V Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37, connUnitSensorStatus, Voltage 3.3V Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37','connUnitSensorStatus','Voltage 3.3V Loc: right-PSU','1','1','3')[0m]
- ( 413 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','413','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37 Voltage 3.3V Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38, connUnitSensorStatus, Current 12V Loc: upper-IOM A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38','connUnitSensorStatus','Current 12V Loc: upper-IOM A','1','1','3')[0m]
- ( 414 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','414','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38 Current 12V Loc: upper-IOM A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39, connUnitSensorStatus, Current 12V Loc: lower-IOM B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39','connUnitSensorStatus','Current 12V Loc: lower-IOM B','1','1','3')[0m]
- ( 415 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','415','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39 Current 12V Loc: lower-IOM B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40, connUnitSensorStatus, Current 12V Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40','connUnitSensorStatus','Current 12V Loc: left-PSU','1','1','3')[0m]
- ( 416 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','416','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40 Current 12V Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41, connUnitSensorStatus, Current 5V Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41','connUnitSensorStatus','Current 5V Loc: left-PSU','1','1','3')[0m]
- ( 417 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','417','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41 Current 5V Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42, connUnitSensorStatus, Current 12V Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42','connUnitSensorStatus','Current 12V Loc: right-PSU','1','1','3')[0m]
- ( 418 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','418','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42 Current 12V Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43, connUnitSensorStatus, Current 5V Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43','connUnitSensorStatus','Current 5V Loc: right-PSU','1','1','3')[0m]
- ( 419 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','419','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43 Current 5V Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44, connUnitSensorStatus, Temperature Loc: upper-IOM A, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44','connUnitSensorStatus','Temperature Loc: upper-IOM A','1','1','3')[0m]
- ( 420 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','420','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44 Temperature Loc: upper-IOM A','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45, connUnitSensorStatus, Temperature Loc: lower-IOM B, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45','connUnitSensorStatus','Temperature Loc: lower-IOM B','1','1','3')[0m]
- ( 421 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','421','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45 Temperature Loc: lower-IOM B','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46, connUnitSensorStatus, Temperature Loc: left-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46','connUnitSensorStatus','Temperature Loc: left-PSU','1','1','3')[0m]
- ( 422 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','422','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46 Temperature Loc: left-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitSensorStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='6'[0m]
- Discover sensor: .1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47, connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47, connUnitSensorStatus, Temperature Loc: right-PSU, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47'[0m]
- SQL[[0;33mINSERT INTO `sensors` (`poller_type`,`sensor_class`,`device_id`,`sensor_oid`,`sensor_index`,`sensor_type`,`sensor_descr`,`sensor_divisor`,`sensor_multiplier`,`sensor_current`) VALUES ('snmp','state','10','.1.3.6.1.3.94.1.8.1.4.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47','connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47','connUnitSensorStatus','Temperature Loc: right-PSU','1','1','3')[0m]
- ( 423 inserted )
- +SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','423','sensor',NOW(),'3','Sensor Added: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47 Temperature Loc: right-PSU','')[0m]
- SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitSensorStatus' AND `sensor_index` = 'connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitSensorStatus'[0m]
- Data connUnitTable: Array
- (
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0] => Array
- (
- [connUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitGlobalId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitType] => 11
- [connUnitNumports] => 8
- [connUnitState] => 2
- [connUnitStatus] => 3
- [connUnitProduct] => HP StorageWorks P2000 G3 iSCSI
- [connUnitSn] => 2S6124C006
- [connUnitUpTime] => 175:2:15:08.02
- [connUnitUrl] => http:172.16.239.230
- [connUnitDomainId] => FF FF FF
- [connUnitProxyMaster] => 3
- [connUnitPrincipal] => 1
- [connUnitNumSensors] => 47
- [connUnitStatusChangeTime] => 175:2:15:08.02
- [connUnitConfigurationChangeTime] => 175:2:15:08.02
- [connUnitNumRevs] => 36
- [connUnitNumZones] => 0
- [connUnitModuleId] => 00
- [connUnitName] => nb-vmmsa
- [connUnitInfo] => 582939-001
- [connUnitControl] => 2
- [connUnitContact] => System Admin paging@nbisd.org
- [connUnitLocation] => EC NOC
- [connUnitEventFilter] => 8
- [connUnitNumEvents] => 40
- [connUnitMaxEvents] => 40
- [connUnitEventCurrID] => 0
- )
- )
- Final sensor value: 2
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitState' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='7'[0m]
- Discover sensor: .1.3.6.1.3.94.1.6.1.5.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0, connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0, connUnitState, nb-vmmsa, snmp, 1, 1, , 2
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitState' AND `sensor_index` = 'connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitState' AND `sensor_index` = 'connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- .SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitState' AND `sensor_index` = 'connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitState'[0m]
- SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('328','7')[0m]
- Data connUnitTable: Array
- (
- [32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0] => Array
- (
- [connUnitId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitGlobalId] => 20 80 00 C0 FF 12 57 7A 00 00 00 00 00 00 00 00
- [connUnitType] => 11
- [connUnitNumports] => 8
- [connUnitState] => 2
- [connUnitStatus] => 3
- [connUnitProduct] => HP StorageWorks P2000 G3 iSCSI
- [connUnitSn] => 2S6124C006
- [connUnitUpTime] => 175:2:15:08.02
- [connUnitUrl] => http:172.16.239.230
- [connUnitDomainId] => FF FF FF
- [connUnitProxyMaster] => 3
- [connUnitPrincipal] => 1
- [connUnitNumSensors] => 47
- [connUnitStatusChangeTime] => 175:2:15:08.02
- [connUnitConfigurationChangeTime] => 175:2:15:08.02
- [connUnitNumRevs] => 36
- [connUnitNumZones] => 0
- [connUnitModuleId] => 00
- [connUnitName] => nb-vmmsa
- [connUnitInfo] => 582939-001
- [connUnitControl] => 2
- [connUnitContact] => System Admin paging@nbisd.org
- [connUnitLocation] => EC NOC
- [connUnitEventFilter] => 8
- [connUnitNumEvents] => 40
- [connUnitMaxEvents] => 40
- [connUnitEventCurrID] => 0
- )
- )
- Final sensor value: 3
- SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'connUnitStatus' LIMIT 1[0m]
- SQL[[0;33mSELECT `state_index_id`,`state_descr`,`state_draw_graph`,`state_value`,`state_generic_value` FROM `state_translations` WHERE `state_index_id`='8'[0m]
- Discover sensor: .1.3.6.1.3.94.1.6.1.6.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0, connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0, connUnitStatus, nb-vmmsa, snmp, 1, 1, , 3
- SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '10' AND sensor_type = 'connUnitStatus' AND `sensor_index` = 'connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitStatus' AND `sensor_index` = 'connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- .SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '10' AND `sensor_type` = 'connUnitStatus' AND `sensor_index` = 'connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0'[0m]
- SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'connUnitStatus'[0m]
- SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`) VALUES ('329','8')[0m]
- Array
- (
- [connUnitSensorStatus] => Array
- (
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.1] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.2] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.3] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.4] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.5] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.6] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.7] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.8] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.9] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.10] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.11] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.12] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.13] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.14] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.15] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.16] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.17] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.18] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.19] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.20] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.21] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.22] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.23] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.24] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.25] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.26] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.27] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.28] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.29] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.30] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.31] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.32] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.33] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.34] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.35] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.36] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.37] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.38] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.39] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.40] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.41] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.42] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.43] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.44] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.45] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.46] => 1
- [connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0.47] => 1
- )
- [connUnitState] => Array
- (
- [connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0] => 1
- )
- [connUnitStatus] => Array
- (
- [connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0] => 1
- )
- )
- SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- connUnitState.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0 -> connUnitState
- connUnitStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0 -> connUnitStatus
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '377'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '377'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 1-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '378'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '378'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 1-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '379'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '379'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 2-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '380'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '380'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 2-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '381'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '381'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 3-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '382'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '382'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. On-Board Temperature 3-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '383'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '383'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Disk Controller Temp-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '384'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '384'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Disk Controller Temp-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '385'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '385'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Memory Controller Temp-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '386'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '386'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Memory Controller Temp-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '387'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '387'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Pack Voltage-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '388'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '388'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Pack Voltage-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '389'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '389'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 1 Voltage-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '390'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '390'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 1 Voltage-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '391'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '391'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 2 Voltage-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '392'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '392'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 2 Voltage-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '393'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '393'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 3 Voltage-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '394'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '394'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 3 Voltage-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '395'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '395'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 4 Voltage-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '396'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '396'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Cell 4 Voltage-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '397'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '397'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Charge-Ctlr A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '398'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '398'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Capacitor Charge-Ctlr B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '399'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '399'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Overall Unit Status','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '400'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '400'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: upper-IOM A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '401'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '401'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: lower-IOM B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '402'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '402'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '403'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '403'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '404'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '404'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 12V Loc: upper-IOM A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '405'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '405'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 5V Loc: upper-IOM A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '406'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '406'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 12V Loc: lower-IOM B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '407'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '407'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 5V Loc: lower-IOM B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '408'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '408'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 12V Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '409'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '409'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 5V Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '410'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '410'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 3.3V Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '411'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '411'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 12V Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '412'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '412'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 5V Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '413'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '413'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Voltage 3.3V Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '414'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '414'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 12V Loc: upper-IOM A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '415'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '415'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 12V Loc: lower-IOM B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '416'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '416'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 12V Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '417'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '417'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 5V Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '418'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '418'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 12V Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '419'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '419'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Current 5V Loc: right-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '420'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '420'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: upper-IOM A','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '421'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '421'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: lower-IOM B','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '422'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '422'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: left-PSU','')[0m]
- connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. -> connUnitSensorStatus
- -SQL[[0;33mDELETE FROM `sensors_to_state_indexes` WHERE `sensor_id` = '423'[0m]
- SQL[[0;33mDELETE FROM `sensors` WHERE `sensor_id` = '423'[0m]
- SQL[[0;33mINSERT INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES ('10','10','NULL','sensor',NOW(),'3','Sensor Deleted: state connUnitSensorStatus connUnitSensorStatus.32.128.0.192.255.18.87.122.0.0.0.0.0.0.0.0. Temperature Loc: right-PSU','')[0m]
- Temperature: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Voltage: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Pressure: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='pressure' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- Cooling: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='cooling' AND S.device_id = D.device_id AND D.device_id = '10' AND S.poller_type = 'snmp'[0m]
- >> Runtime for discovery module 'sensors': 3.7730 seconds with 11024 bytes
- >> SNMP: [4/3.38s] MySQL: [514/0.43s] RRD: [0/0.00s]
- #### Unload disco module sensors ####
- SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '10' AND `attrib_type` = 'poll_mib' [0m]
- SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='6.865' WHERE `device_id` = '10'[0m]
- Discovered in 6.865 seconds
- SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES ('discover','172.16.239.230','1512832315.8705','6.979','1','dev-server.nbisd.edu')[0m]
- ./discovery.php 172.16.239.230 2017-12-09 09:12:02 - 1 devices discovered in 6.979 secs
- SNMP [4/3.38s]: Get[1/0.06s] Getnext[0/0.00s] Walk[3/3.32s]
- MySQL [517/0.43s]: Cell[100/0.08s] Row[103/0.08s] Rows[74/0.05s] Column[0/0.00s] Update[1/0.00s] Insert[145/0.17s] Delete[94/0.06s]
- RRD [0/0.00s]: Update[0/0.00s] Create [0/0.00s] Other[0/0.00s]