SQL[[1;33mselect `version` from `dbSchema` order by `version` desc limit 1 [0;33m[][0m 0.
SQL[[1;33mSELECT version() [0;33m[][0m 0.
===================================
Version info:
Commit SHA:
Commit Date:
DB Schema: 269
PHP: 7.0.32-0ubuntu0.16.04.1
MySQL: 10.0.36-MariaDB-0ubuntu0.16.04.1
RRDTool: 1.5.5
SNMP: NET-SNMP 5.7.3
==================================DEBUG!
Updating os_def.cache... Done
Starting polling run:
SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ?
Hostname: 130.126.110.253
Device ID: 45
OS: jetdirect
Warning: inet_pton(): Unrecognized address in /opt/librenms/includes/polling/functions.inc.php on line 248
(printer)
math-pp-ah123.math.illinois.edu 46 jetdirect [FPING] /usr/bin/fping -e -q -c 3 -p 500 -t 500
Array
(
[xmt] => 3
[rcv] => 3
[loss] => 0
[min] => 0.
[max] =>
[avg] => 0.
[exitcode] => 0
)
SQL[[1;33mINSERT IGNORE INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`) VALUES (:xmt,:rcv,:loss,:min,:max,:avg,:device_id,NOW()) [0;33m{"xmt":"3","rcv":"3","loss":"0","min":"0.
SNMP Check response code: 0
SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[46,"poll_mib"][0m 0.31ms]
Attempting to initialize OS: jetdirect
Attempting to initialize OS: printer
OS initilized as Generic
Modules status: Global+ OS Device
#### Load
SNMP[[0;36m/usr/bin/snmpget -v2c -c
.
.*.*.0 =
.*.*.0 =
.*.*.0 = ih325
.*.*.
.1.3.6.1.2.1.1.2.0 = .
.
SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OQnUst -m HOST-RESOURCES-MIB:SNMP-FRAMEWORK-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 snmpEngineTime.0 hrSystemUptime.0[0m]
snmpEngineTime.0 = No Such Instance currently exists at this OID
hrSystemUptime.0 = No Such Instance currently exists at this OID
Uptime seconds: 642760
RRD[[0;32mupdate 130.126.110.253/uptime.rrd N:642760 --daemon unix:/var/run/rrdcached.sock[0m]
[[0;31mRRD Disabled[0m]Uptime: 7 days, 10h 32m 40s
>> Runtime for
>> SNMP: [2/0.02s] MySQL:
#### Unload
#### Load disco module os ####
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Ovq -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 SNMPv2-MIB::sysDescr.0[0m]
HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070,CIDATE 02/24/2016
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Ovqn -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 SNMPv2-MIB::sysObjectID.0[0m]
.1.3.6.1.4.1.11.2.3.9.1
| HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070,CIDATE 02/24/2016 | .1.3.6.1.4.1.11.2.3.9.1 |
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Oqv -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 .1.3.6.1.4.1.12148.10.2.6.0[0m]
No Such Object available on this agent at this OID
OS: HP Print server (jetdirect)
>> Runtime for discovery module 'os': 0.0260 seconds with 1384 bytes
>> SNMP: [3/0.03s] MySQL: [0/0.00s] RRD: [0/0.00s]
#### Unload disco module os ####
Modules status: Global+ OS+ Device
#### Load disco module ports ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m IF-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ifDescr[0m]
ifDescr.1 = HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070
ifDescr.2 = HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m IF-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ifName[0m]
ifName = No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m IF-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ifAlias[0m]
ifAlias = No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m IF-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ifType[0m]
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd
Array
(
[1] => Array
(
[ifDescr] => HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070
[ifType] => softwareLoopback
)
[2] => Array
(
[ifDescr] => HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070
[ifType] => ethernetCsmacd
)
)
SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[46][0m 0.59ms]
..
>> Runtime for discovery module 'ports': 0.5260 seconds with 4272 bytes
>> SNMP: [4/0.53s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module ports ####
Modules status: Global+ OS+ Device
#### Load disco module ports-stack ####
SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '46' [0;33m[][0m 0.22ms]
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m IF-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ifStackStatus[0m]
ifStackStatus = No Such Object available on this agent at this OID
>> Runtime for discovery module 'ports-stack': 0.2720 seconds with 1784 bytes
>> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module ports-stack ####
Modules status: Global+ OS+ Device
#### Load disco module entity-physical ####
Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 entPhysicalEntry[0m]
entPhysicalEntry = No Such Object available on this agent at this OID
SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[46][0m 0.39ms]
>> Runtime for discovery module 'entity-physical': 0.0220 seconds with 5504 bytes
>> SNMP: [1/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module entity-physical ####
Modules status: Global- OS- Device Module [ entity-state ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module processors ####
No YAML Discovery data.
Host Resources: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m HOST-RESOURCES-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 hrProcessorLoad[0m]
hrProcessorLoad = No Such Instance currently exists at this OID
UCD Resources: SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[46][0m 0.92ms]
SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[46][0m 0.17ms]
SQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[46][0m 0.21ms]
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Ovq -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 .1.3.6.1.4.1.2021.11.11.0[0m]
No Such Object available on this agent at this OID
SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[46][0m 0.52ms]
SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.3ms]
>> Runtime for discovery module 'processors': 0.3090 seconds with 74432 bytes
>> SNMP: [2/0.31s] MySQL: [5/0.00s] RRD: [0/0.00s]
#### Unload disco module processors ####
Modules status: Global+ OS+ Device
#### Load disco module mempools ####
SQL[[1;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = ? AND `mempool_type` = 'cemp' [0;33m[46][0m 0.34ms]
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:math-pp-ah123.math.illinois.edu:161 hpLocal[0m]
hpLocalMem = No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:math-pp-ah123.math.illinois.edu:161 hpGlobal[0m]
hpGlobalMem = No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 hrStorageEntry[0m]
hrStorageEntry = No Such Instance currently exists at this OID
SQL[[1;33mSELECT * FROM `mempools` WHERE `device_id` = '46' [0;33m[][0m 0.4ms]
>> Runtime for discovery module 'mempools': 0.1620 seconds with 28648 bytes
>> SNMP: [3/0.16s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module mempools ####
Modules status: Global+ OS+ Device
#### Load disco module cisco-vrf-lite ####
SQL[[1;33mSELECT * FROM vrf_lite_cisco WHERE device_id = ? [0;33m[46][0m 0.19ms]
>> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 2664 bytes
>> SNMP: [0/0.00s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module cisco-vrf-lite ####
Modules status: Global- OS- Device Module [ cisco-mac-accounting ] disabled on os.
Modules status: Global- OS- Device Module [ cisco-pw ] disabled on os.
Modules status: Global- OS- Device Module [ vrf ] disabled on os.
Modules status: Global- OS- Device Module [ cisco-cef ] disabled on os.
Modules status: Global- OS- Device Module [ cisco-sla ] disabled on os.
Modules status: Global- OS- Device Module [ cisco-cbqos ] disabled on os.
Modules status: Global- OS- Device Module [ cisco-otv ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module ipv4-addresses ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -Osq -m IP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipAdEntIfIndex[0m]
ipAdEntIfIndex.130.126.110.
[[0;31mRRD Disabled[0m]Modules
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Oqv -m IP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipAdEntNetMask.130.126.110.254[0m]
255.255.252.0
SQL[[1;33mSELECT COUNT(*) FROM `ports` WHERE device_id = ? AND `ifIndex` = ? [0;33m[46,"2"][0m 0.48ms]
SQL[[1;33mSELECT `port_id` FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[46,"2"][0m 0.19ms]
SQL[[1;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["130.126.110.254\/22"][0m 0.2ms]
SQL[[1;33mUPDATE `ipv4_networks` set `context_name`=? WHERE `ipv4_network` = ? [0;33m[null,"130.126.110.254\/22"][0m 2.97ms]
sSQL[[1;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = ? [0;33m["130.126.110.254\/22"][0m 0.19ms]
SQL[[1;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m["130.126.110.254",22,50][0m 0.21ms]
SQL[[1;33mUPDATE `ipv4_addresses` set `context_name`=? WHERE `ipv4_address` = ? AND `ipv4_prefixlen` = ? AND `port_id` = ? [0;33m[null,"130.126.110.254",22,50][0m 0.88ms]
.SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[46][0m 0.5ms]
>> Runtime for discovery module 'ipv4-addresses': 0.0270 seconds with 34480 bytes
>> SNMP: [2/0.02s] MySQL: [3/0.00s] RRD: [0/0.00s]
#### Unload disco module ipv4-addresses ####
Modules status: Global+ OS+ Device
#### Load
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipAddressIfIndex.ipv6[0m]
ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipv6AddrPfxLength[0m]
.1.3.6.1.2.1.55.1.8.1.2 No Such Object available on this agent at this OID
SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[46][0m 0.6ms]
>> Runtime for discovery module 'ipv6-addresses': 0.0240 seconds with 3424 bytes
>> SNMP: [2/0.02s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module ipv6-addresses ####
Modules status: Global- OS- Device Module [ route ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module sensors ####
ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m ENTITY-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 entPhysicalDescr[0m]
entPhysicalDescr = No Such Object available on this agent at this OID
SQL[[1;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = ? AND `attrib_type` = ? [0;33m[46,"ipmi_hostname"][0m 0.29ms]
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",46,"ipmi"][0m 0.72ms]
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",46,"ipmi"][0m 0.31ms]
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",46,"ipmi"][0m 0.31ms]
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",46,"ipmi"][0m 0.36ms]
Airflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",46,"snmp"][0m 0.32ms]
Current: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",46,"snmp"][0m 0.3ms]
Charge: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",46,"snmp"][0m 0.3ms]
Dbm: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",46,"snmp"][0m 0.3ms]
Fanspeed: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",46,"snmp"][0m 0.31ms]
Frequency: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",46,"snmp"][0m 0.34ms]
Humidity: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",46,"snmp"][0m 0.32ms]
Load: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",46,"snmp"][0m 0.3ms]
Power: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",46,"snmp"][0m 0.33ms]
Runtime: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",46,"snmp"][0m 0.3ms]
Signal: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",46,"snmp"][0m 0.3ms]
State: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",46,"snmp"][0m 0.37ms]
Temperature: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",46,"snmp"][0m 0.3ms]
Voltage: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",46,"snmp"][0m 0.33ms]
Snr: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",46,"snmp"][0m 0.3ms]
Pressure: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",46,"snmp"][0m 0.34ms]
Cooling: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",46,"snmp"][0m 0.33ms]
Delay: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",46,"snmp"][0m 0.53ms]
Quality_factor: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",46,"snmp"][0m 0.36ms]
Chromatic_dispersion: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",46,"snmp"][0m 0.37ms]
Ber: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",46,"snmp"][0m 0.36ms]
Eer: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",46,"snmp"][0m 0.29ms]
Waterflow: SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",46,"snmp"][0m 0.3ms]
>> Runtime for discovery module 'sensors': 0.0230 seconds with 46168 bytes
>> SNMP: [1/0.01s] MySQL: [28/0.01s] RRD: [0/0.00s]
#### Unload disco module sensors ####
Modules status: Global+ OS+ Device
#### Load disco module storage ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m DATA-DOMAIN-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/datadomain udp:math-pp-ah123.math.illinois.edu:161 fileSystemSpaceTable[0m]
fileSystemSpaceTable = No more variables left in this MIB View (It is past the end of the MIB tree)
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 hrStorageEntry[0m]
hrStorageEntry = No Such Instance currently exists at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 dskTable[0m]
dskTable = No Such Object available on this agent at this OID
SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '46' AND `storage_type` != 'dsk' [0;33m[][0m 0.39ms]
SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '46' [0;33m[][0m 0.32ms]
>> Runtime for discovery module 'storage': 0.1370 seconds with 9176 bytes
>> SNMP: [3/0.13s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module storage ####
Modules status: Global+ OS+ Device
#### Load disco module hr-device ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 hrDeviceEntry[0m]
hrDeviceIndex.1 = 1
hrDeviceIndex.2 = 2
hrDeviceType.1 = hrDevicePrinter
hrDeviceType.2 = hrDeviceDiskStorage
hrDeviceDescr.1 = HP LaserJet 600 M602
hrDeviceDescr.2 = SanDisk SSD P4 4GB
hrDeviceID.1 = enterprises.11.2.3.9.1.90.4
hrDeviceID.2 = zeroDotZero
hrDeviceStatus.1 = warning
hrDeviceStatus.2 = running
hrDeviceErrors.1 = 14
hrDeviceErrors.2 = 0
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 hrProcessorEntry[0m]
hrProcessorEntry = No Such Instance currently exists at this OID
Array
(
[1] => Array
(
[hrDeviceIndex] => 1
[hrDeviceType] => hrDevicePrinter
[hrDeviceDescr] => HP LaserJet 600 M602
[hrDeviceID] => enterprises.11.2.3.9.1.90.4
[hrDeviceStatus] => warning
[hrDeviceErrors] => 14
)
[2] => Array
(
[hrDeviceIndex] => 2
[hrDeviceType] => hrDeviceDiskStorage
[hrDeviceDescr] => SanDisk SSD P4 4GB
[hrDeviceID] => zeroDotZero
[hrDeviceStatus] => running
[hrDeviceErrors] => 0
)
)
SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[46,"1"][0m 0.74ms]
SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDevicePrinter","HP LaserJet 600 M602","warning","14",46,"1"][0m 0.85ms]
.SQL[[1;33mSELECT COUNT(*) FROM `hrDevice` WHERE device_id = ? AND hrDeviceIndex = ? [0;33m[46,"2"][0m 0.24ms]
SQL[[1;33mUPDATE `hrDevice` set `hrDeviceType`=?,`hrDeviceDescr`=?,`hrDeviceStatus`=?,`hrDeviceErrors`=? WHERE device_id=? AND hrDeviceIndex=? [0;33m["hrDeviceDiskStorage","SanDisk SSD P4 4GB","running","0",46,"2"][0m 0.41ms]
.SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '46' [0;33m[][0m 0.21ms]
>> Runtime for discovery module 'hr-device': 0.6060 seconds with 6928 bytes
>> SNMP: [2/0.60s] MySQL: [3/0.00s] RRD: [0/0.00s]
#### Unload disco module hr-device ####
Modules status: Global+ OS+ Device
#### Load disco module discovery-protocols ####
CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 cdpCache[0m]
cdpCache = No Such Object available on this agent at this OID
LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m LLDP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 lldpRemTable[0m]
lldpRemTable = No Such Object available on this agent at this OID
OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[46][0m 0.48ms]
SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[46][0m 0.6ms]
SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 0.18ms]
0 orphaned links deleted
>> Runtime for discovery module 'discovery-protocols': 0.0320 seconds with 5112 bytes
>> SNMP: [0/0.00s] MySQL: [3/0.00s] RRD: [0/0.00s]
#### Unload disco module discovery-protocols ####
Modules status: Global+ OS+ Device
#### Load disco module arp-table ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipNetToPhysicalPhysAddress[0m]
ipNetToPhysicalPhysAddress = No Such Object available on this agent at this OID
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m IP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 ipNetToMediaPhysAddress[0m]
ipNetToMediaPhysAddress[2][130.126.108.1] = e8:ed:f3:25:e5:c1
ipNetToMediaPhysAddress[2][130.126.108.238] = 98:5a:eb:da:bc:1c
ipNetToMediaPhysAddress[2][130.126.109.129] = 8:0:37:e4:c5:5d
ipNetToMediaPhysAddress[2][130.126.109.130] = 8:0:37:e4:c4:e9
ipNetToMediaPhysAddress[2][130.126.109.131] = 8:0:37:e4:bd:65
ipNetToMediaPhysAddress[2][130.126.109.132] = 8:0:37:e4:bd:31
ipNetToMediaPhysAddress[2][130.126.110.16] = 0:50:56:99:2f:5b
ipNetToMediaPhysAddress[2][130.126.110.234] = a8:60:b6:a:59:de
ipNetToMediaPhysAddress[2][130.126.111.16] = 18:3:73:e5:e9:f6
ipNetToMediaPhysAddress[2][130.126.111.29] = 34:17:eb:d8:ae:56
ipNetToMediaPhysAddress[2][130.126.111.33] = 0:c:29:c:78:73
ipNetToMediaPhysAddress[2][130.126.111.58] = 78:7b:8a:ac:13:5b
ipNetToMediaPhysAddress[2][130.126.111.255] = ff:ff:ff:ff:ff:ff
SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[46,""][0m 1.09ms]
SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? AND `ifIndex` = ? [0;33m[46,2][0m 0.35ms]
HP ETHERNET MULTI-ENVIRONMENT,ROM none,JETDIRECT,JD149,EEPROM JDI23701070:
e8:ed:f3:25:e5:c1 => 130.126.108.1
98:5a:eb:da:bc:1c => 130.126.108.238
8:0:37:e4:c5:5d => 130.126.109.129
8:0:37:e4:c4:e9 => 130.126.109.130
8:0:37:e4:bd:65 => 130.126.109.131
8:0:37:e4:bd:31 => 130.126.109.132
0:50:56:99:2f:5b => 130.126.110.16
a8:60:b6:a:59:de => 130.126.110.234
18:3:73:e5:e9:f6 => 130.126.111.16
34:17:eb:d8:ae:56 => 130.126.111.29
0:c:29:c:78:73 => 130.126.111.33
78:7b:8a:ac:13:5b => 130.126.111.58
ff:ff:ff:ff:ff:ff => 130.126.111.255
SQL[[1;33minsert into `ipv4_mac` (`context_name`, `device_id`, `ipv4_address`, `mac_address`, `port_id`) values (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?), (?, ?, ?, ?, ?) [0;33m["",46,"130.126.109.129","080037e4c55d",50,"",46,"130.126.109.130","080037e4c4e9",50,"",46,"130.126.110.234","a860b60a59de",50,"",46,"130.126.111.58","787b8aac135b",50][0m 1.02ms]
SQL[[1;33mDELETE FROM `ipv4_mac` WHERE `port_id` = ? AND `mac_address`=? AND `ipv4_address`=? AND `context_name`=? [0;33m[50,"00232499d33a","130.126.108.147",""][0m 0.47ms]
SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 0.87ms]
>> Runtime for discovery module 'arp-table': 0.0320 seconds with 17592 bytes
>> SNMP: [0/0.00s] MySQL: [5/0.00s] RRD: [0/0.00s]
#### Unload disco module arp-table ####
Modules status: Global+ OS+ Device
#### Load disco module discovery-arp ####
SQL[[1;33m
SELECT *
FROM ipv4_mac as m, ports as i
WHERE m.port_id = i.port_id
AND i.device_id = ?
AND i.deleted = 0
AND NOT EXISTS (
SELECT * FROM ipv4_addresses a
WHERE a.ipv4_address = m.ipv4_address
)
GROUP BY ipv4_address
ORDER BY ipv4_address
[0;33m[46][0m 1.92ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
SQL[[1;33mSELECT `devices`.*, `lat`, `lng` FROM `devices` LEFT JOIN locations ON `devices`.`location`=`locations`.`location` WHERE `device_id` = ? [0;33m[null][0m 0.43ms]
SQL[[1;33mSELECT * FROM devices_attribs WHERE `device_id` = ? [0;33m[null][0m 0.14ms]
No OS to loadSQL[[1;33mSELECT * FROM `vrf_lite_cisco` WHERE `device_id` = ? [0;33m[null][0m 0.13ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.108.1","username":""}[0m 0.94ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.108.238","username":""}[0m 0.51ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.110.16","username":""}[0m 0.27ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.110.234","username":""}[0m 0.28ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.111.16","username":""}[0m 0.29ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.111.255","username":""}[0m 0.56ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.111.29","username":""}[0m 0.3ms]
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 83
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 84
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 85
Warning: Cannot use a scalar value as an array in /opt/librenms/includes/rewrites.php on line 102
iSQL[[1;33mINSERT IGNORE INTO `eventlog` (`host`,`device_id`,`reference`,`type`,`datetime`,`severity`,`message`,`username`) VALUES (:host,:device_id,:reference,:type,NOW(),:severity,:message,:username) [0;33m{"host":46,"device_id":46,"reference":50,"type":"interface","severity":3,"message":"Ignored 130.126.111.58","username":""}[0m 0.3ms]
>> Runtime for discovery module 'discovery-arp': 0.0210 seconds with 1658728 bytes
>> SNMP: [0/0.00s] MySQL: [12/0.01s] RRD: [0/0.00s]
#### Unload disco module discovery-arp ####
Modules status: Global- OS- Device Module [ junose-atm-vp ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module bgp-peers ####
SNMP[[0;36m/usr/bin/snmpgetnext -v2c -c 'public' -Oqvn -m BGP4-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 bgpLocalAs[0m]
198572
AS198572 SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -Oq -m BGP4-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 bgpPeerRemoteAs[0m]
BGP4-MIB::bgpPeerRemoteAs No Such Object available on this agent at this OID
Peers :
SQL[[1;33mDELETE FROM `bgpPeers` WHERE device_id=? AND context_name=? [0;33m[46,""][0m 0.33ms]
SQL[[1;33mDELETE FROM `bgpPeers_cbgp` WHERE device_id=? AND context_name=? [0;33m[46,""][0m 0.35ms]
SQL[[1;33mSELECT DISTINCT context_name FROM bgpPeers WHERE device_id=? [0;33m[46][0m 0.15ms]
>> Runtime for discovery module 'bgp-peers': 0.1210 seconds with 5616 bytes
>> SNMP: [2/0.12s] MySQL: [2/0.00s] RRD: [0/0.00s]
#### Unload disco module bgp-peers ####
Modules status: Global+ OS+ Device
#### Load disco module vlans ####
SQL[[1;33mSELECT * FROM
Checking toner Black Cartridge 90X HP CE390X....
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 dot1dBasePortIfIndex[0m]
dot1dBasePortIfIndex = No Such Object available on this agent at this OID
IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c
No Such Object available on this agent at this OID
>> Runtime for discovery module 'vlans': 0.1170 seconds with 9240 bytes
>> SNMP: [2/0.12s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module vlans ####
Modules status: Global- OS- Device Module [ vmware-vminfo ] disabled on os.
Modules status: Global- OS- Device Module [ libvirt-vminfo ] disabled on os.
Modules status: Global- OS+ Device
#### Load disco module toner ####
Toner: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m Printer-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 prtMarkerSuppliesLevel[0m]
prtMarkerSuppliesLevel.1.1 = 92
prtMarkerSuppliesLevel.1.2 = 35
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m Printer-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 prtMarkerSuppliesMaxCapacity[0m]
prtMarkerSuppliesMaxCapacity.1.1 = 100
prtMarkerSuppliesMaxCapacity.1.2 = 100
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsa -m Printer-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 prtMarkerSuppliesDescription[0m]
prtMarkerSuppliesDescription.1.1 = "Black Cartridge 90X HP CE390X."
prtMarkerSuppliesDescription.1.2 = "Maintenance Kit HP 110V-CF064A, 220V-CF065A."
Discover Toner: .1.3.6.1.2.1.43.11.1.1.9.1.
19
19 %
RRD[[0;32mupdate 130.126.110.253/toner-1.rrd N:19 --daemon unix:/var/run/rrdcached.sock[0m]
[[0;31mRRD Disabled[0m]SQL[[1;33mUPDATE
SQL[[1;33mSELECT COUNT(toner_id) FROM `toner`
Checking toner Maintenance Kit HP 110V-CF064A, ... SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -OUqnv -M /opt/librenms/mibs udp:HOSTNAME:161 .
82
82 %
RRD[[0;32mupdate 130.126.110.253/toner-2.rrd N:82 --daemon unix:/var/run/rrdcached.sock[0m]
[[0;31mRRD Disabled[0m]SQL[[1;33mUPDATE
SQL[[1;33mSELECT * FROM `toner` WHERE `device_id` = ? AND `toner_type` = ? AND `toner_index` =? [0;33m[46,"jetdirect","1"][0m 0.25ms]
.Discover Toner: .1.3.6.1.2.1.43.11.1.1.9.1.2, 2, jetdirect, Maintenance Kit HP 110V-CF064A, 220V-CF065A., .1.3.6.1.2.1.43.11.1.1.8.1.2, 100, 35
SQL[[1;33mSELECT COUNT(toner_id) FROM `toner` WHERE device_id = ? AND toner_type = ? AND `toner_index` = ? AND `toner_oid` =? [0;33m[46,"jetdirect","2",".1.3.6.1.2.1.43.11.1.1.9.1.2"][0m 0.21ms]
SQL[[1;33mSELECT * FROM `toner` WHERE `device_id` = ? AND `toner_type` = ? AND `toner_index` =? [0;33m[46,"jetdirect","2"][0m 0.21ms]
SQL[[1;33mUPDATE `toner` set
U
Checking valid toner ...
Array
(
[jetdirect] => Array
(
[.1.3.6.1.2.1.43.11.1.1.9.1.1] => 1
[.1.3.6.1.2.1.43.11.1.1.9.1.2] => 1
)
)
SQL[[1;33mSELECT * FROM toner WHERE device_id =
Array
(
[0] => Array
(
[toner_id] => 22
[device_id] => 46
[toner_index] => 2
[toner_type] => jetdirect
[toner_oid] => .1.
[toner_descr] => Maintenance Kit HP 110V-CF064A,
[toner_capacity] => 100
[toner_current] => 35
[toner_capacity_oid] => .1.3.6.1.2.1.43.11.1.1.8.1.2
)
[1] => Array
(
[toner_id] => 129
[device_id] => 46
[toner_index] => 1
[toner_type] => jetdirect
[toner_oid] => .1.3.6.1.2.1.43.11.1.1.9.1.1
[toner_descr] => Black Cartridge 90X HP CE390X.
[toner_capacity] => 100
[toner_current] => 92
[toner_capacity_oid] => .1.3.6.1.2.1.43.11.1.1.8.1.1
)
)
>> Runtime for
>> SNMP:
#### Unload
[[0;31mRRD Disabled[0m]### Start Device Groups ###
#### Load disco module ucd-diskio ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 diskIOEntry[0m]
diskIOEntry = No Such Object available on this agent at this OID
Array
(
)
SQL[[1;33mSELECT * FROM
>> Runtime for discovery module 'ucd-diskio': 0.0110 seconds with 3160 bytes
>> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module ucd-diskio ####
Modules status: Global- OS- Device Module [ applications ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module services ####
>> Runtime for discovery module 'services': 0.0000 seconds with 296 bytes
>> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
#### Unload disco module services ####
Modules status: Global+ OS+ Device
#### Load disco module stp ####
SQL[[1;33mSELECT * FROM `stp` WHERE `device_id` = ? [0;33m[46][0m 0.17ms]
SNMP[[0;36m/usr/bin/snmpget -v2c -c 'public' -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 dot1dStpProtocolSpecification.0[0m]
No Such Object available on this agent at this OID
>> Runtime for discovery module 'stp': 0.0100 seconds with 5792 bytes
>> SNMP: [1/0.01s] MySQL: [1/0.00s] RRD: [0/0.00s]
#### Unload disco module stp ####
Modules status: Global+ OS+ Device
#### Load disco module ntp ####
>> Runtime for discovery module 'ntp': 0.0000 seconds with 232 bytes
>> SNMP: [0/0.00s] MySQL: [0/0.00s] RRD: [0/0.00s]
#### Unload disco module ntp ####
Modules status: Global- OS- Device Module [ loadbalancers ] disabled on os.
Modules status: Global- OS- Device Module [ mef ] disabled on os.
Modules status: Global+ OS+ Device
#### Load disco module wireless ####
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"ap-count"][0m 0.42ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"clients"][0m 0.17ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"quality"][0m 0.19ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"capacity"][0m 0.18ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"utilization"][0m 0.17ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"rate"][0m 0.21ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"ccq"][0m 0.16ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"snr"][0m 0.22ms]
SQL[[1;33mSELECT
SQL[[1;33mSELECT
SQL[[1;33mSELECT
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"power"][0m 0.18ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"noise-floor"][0m 0.24ms]
SQL[[1;33mSELECT
SQL[[1;33mSELECT `device_group_id` FROM `device_group_device`
Groups Added:
Groups Removed:
### End Device Groups ###
RRD[[0;32mupdate 130.126.110.253/ping-perf.rrd N:0.79 --daemon unix:/var/run/rrdcached.sock[0m]
[[0;31mRRD Disabled[0m]RRD[[0;32mupdate 130.126.110.253/poller-perf.rrd N:1.084 --daemon unix:/var/run/rrdcached.sock[0m]
[[0;31mRRD Disabled[0m]SQL[[1;33mUPDATE `devices` set `uptime`=?,`last_ping`=NOW(),`last_ping_timetaken`=?
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"error-ratio"][0m 0.27ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"error-rate"][0m 0.26ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"frequency"][0m 0.22ms]
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[46,"distance"][0m 0.2ms]
>> Runtime for discovery module 'wireless': 0.0070 seconds with 123040 bytes
>> SNMP: [0/0.00s] MySQL: [18/0.00s] RRD: [0/0.00s]
#### Unload disco module wireless ####
Modules status: Global+ OS+ Device
#### Load disco module fdb-table ####
SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ?
Updating 130.126.110.253
Polled in 1.084 seconds
#### Start Alerts ####
SQL[[1;33mSELECT `device_group_id` FROM `device_group_device` WHERE `device_id`=? [0;33m[45][0m 0.15ms]
SQL[[1;33mSELECT alert_schedule.schedule_id FROM alert_schedule LEFT JOIN alert_schedule_items ON alert_schedule.schedule_id=alert_schedule_items.schedule_id WHERE ( alert_schedule_items.target = ? || alert_schedule_items.target = ? || alert_schedule_items.target = ? ) && ((alert_schedule.recurring = 0 AND (NOW() BETWEEN alert_schedule.start AND alert_schedule.end)) OR (alert_schedule.recurring = 1 AND (alert_schedule.start_recurring_dt <= date_format(NOW(), '[1;33m-[0;35m-%d') AND (end_recurring_dt >= date_format(NOW(), '[1;33m-[0;35m-%d') OR end_recurring_dt is NULL OR end_recurring_dt = '0000-00-00' OR end_recurring_dt = '')) AND (date_format(now(), '%H:%i:%s') BETWEEN `start_recurring_hr` AND end_recurring_hr) AND (recurring_day LIKE CONCAT('%',date_format(now(), '[0;37m'),'%') OR recurring_day is null or recurring_day = ''))) LIMIT 1 [0;33m[45,"g2","g5"][0m 0.41ms]
SQL[[1;33mSELECT DISTINCT a.* FROM alert_rules a
LEFT JOIN alert_device_map d ON a.id=d.rule_id
LEFT JOIN alert_group_map g ON a.id=g.rule_id
LEFT JOIN device_group_device dg ON g.group_id=dg.device_group_id
WHERE a.disabled = 0 AND ((d.device_id IS NULL AND g.group_id IS NULL) OR d.device_id=? OR dg.device_id=?) [0;33m[45,45][0m 0.
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 dot1qTpFdbPort[0m]
dot1qTpFdbPort =
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c 'public' -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:math-pp-ah123.math.illinois.edu:161 dot1dTpFdbPort[0m]
dot1dTpFdbPort =
>> Runtime for discovery module 'fdb-table': 0.
>> SNMP: [0/0.00s] MySQL: [2/0.00s] RRD: [0/0.00s]
#### Unload disco module fdb-table ####
SQL[[1;33mSELECT
Status: [0;34mNOCHG[0m
Rule [0;35m#3 (BGP Session down):[0m
SQL[[1;33mSELECT * FROM bgpPeers,devices WHERE (( devices.device_id = bgpPeers.device_id ) && bgpPeers.device_id = ?) && (bgpPeers.bgpPeerState != "established" && ((devices.status = 1 && ((devices.disabled = 0 && devices.ignore = 0)))) = "1") [0;33m[45][0m 0.34ms]
SQL[[1;33mSELECT state FROM alerts WHERE rule_id = ? AND device_id = ? ORDER BY id DESC LIMIT 1 [0;33m[3,45][0m 0.14ms]
Status: [0;34mNOCHG[0m
Rule [0;35m#4 (BGP Session established):[0m
SQL[[1;33mSELECT * FROM bgpPeers WHERE (bgpPeers.device_id = ?) && (bgpPeers.bgpPeerFsmEstablishedTime < "300" && bgpPeers.bgpPeerState = "established") [0;33m[45][0m 0.21ms]
SQL[[1;33mSELECT state FROM alerts WHERE rule_id = ? AND device_id = ? ORDER BY id DESC LIMIT 1 [0;33m[4,45][0m 0.14ms]
Status: [0;34mNOCHG[0m
Rule [0;35m#5 (Port status up/down):[0m
SQL[[1;33mSELECT * FROM ports WHERE (ports.device_id = ?) && (((ports.ifOperStatus = "down" && ports.ifAdminStatus != "down" && ((ports.deleted = 0 && ports.ignore = 0 && ports.disabled = 0)))) = "1") [0;33m[45][0m 0.
Status: [0;34mNOCHG[0m
Rule [0;35m#6 (Port utilisation over threshold):[0m
SQL[[1;33mSELECT * FROM ports WHERE (ports.device_id = ?) && ((((ports.ifInOctets_rate*8) / ports.ifSpeed)*100) >= "80" && ((ports.ifOperStatus = "up" && ports.ifAdminStatus = "up" && ((ports.deleted = 0 && ports.ignore = 0 && ports.disabled = 0)))) = "1" && ((ports.deleted = 0 && ports.ignore = 0 && ports.disabled = 0)) = "1") [0;33m[45][0m 0.49ms]
SQL[[1;33mSELECT state FROM alerts WHERE rule_id = ? AND device_id = ? ORDER BY id DESC LIMIT 1 [0;33m[6,45][0m 0.13ms]
Status: [0;34mNOCHG[0m
Rule [0;35m#7 (Sensor over limit):[0m
SQL[[1;33mSELECT * FROM sensors WHERE (sensors.device_id = ?) && (sensors.sensor_current > sensors.sensor_limit && sensors.sensor_alert = "1") [0;33m[45][0m 0.16ms]
SQL[[1;33mSELECT state FROM alerts WHERE rule_id = ? AND device_id = ? ORDER BY id DESC LIMIT 1 [0;33m[7,45][0m 0.13ms]
Status: [0;34mNOCHG[0m
Rule [0;35m#8 (Sensor under limit):[0m
SQL[[1;33mSELECT * FROM sensors WHERE (sensors.device_id = ?) && (sensors.sensor_current < sensors.sensor_limit_low && sensors.sensor_alert = "1") [0;33m[45][0m 0.18ms]
SQL[[1;33mSELECT state FROM alerts WHERE rule_id = ? AND device_id = ? ORDER BY id DESC LIMIT 1 [0;33m[8,45][0m 0.17ms]
Status: [0;34mNOCHG[0m
#### End Alerts ####
Discovered in 4.013 seconds
SQL[[1;33mINSERT IGNORE INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`) VALUES (:type,:doing,:start,:duration,:devices,:poller)
./poller.
./discovery.php
SNMP
MySQL [102/0.05s]: Cell[11/0.00s]