From root, 6 Years ago, written in Plain Text.
Embed
  1. LibreNMS Discovery
  2. ===================================
  3. Version info:
  4. Commit SHA: 5e5684f2cd7077c12663d97ac5e563bdc603d3aa
  5. Commit Date: 1505328699
  6. DB Schema: 206
  7. PHP: 7.0.20
  8. MySQL: 5.5.52-MariaDB
  9. RRDTool: 1.4.8
  10. SNMP: NET-SNMP 5.7.2
  11. ==================================DEBUG!
  12. SQL[[0;33mSELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE '172.31.23.222' ORDER BY device_id DESC[0m]
  13. SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '19'[0m]
  14. 172.31.23.222 19 poweralert SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','0.73','0.78','0.76','19',NOW())[0m]
  15. SNMP Check response code: 0
  16. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '19' AND `attrib_type` = 'poll_mib' [0m]
  17.  
  18. Modules status: Global+ OS+ Device  
  19. #### Load disco module os ####
  20. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
  21. POWERALERT 12
  22.  
  23. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
  24. .*.4.1.850.1
  25.  
  26. | POWERALERT 12 | .1.3.6.1.4.1.850.1 |
  27.  
  28. >> Runtime for discovery module 'os': 0.0860 seconds with 848 bytes
  29. #### Unload disco module os ####
  30.  
  31. Modules status: Global+ OS+ Device  
  32. #### Load disco module ports ####
  33. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifDescr[0m]
  34. ifDescr.1 = eth0
  35. ifDescr.2 = LOOPBACK
  36.  
  37. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifName[0m]
  38. ifName = No Such Object available on this agent at this OID
  39.  
  40. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifAlias[0m]
  41. ifAlias = No Such Object available on this agent at this OID
  42.  
  43. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifType[0m]
  44. ifType.1 = softwareLoopback
  45. ifType.2 = ethernetCsmacd
  46.  
  47. Array
  48. (
  49.     [1] => Array
  50.         (
  51.             [ifDescr] => eth0
  52.             [ifType] => softwareLoopback
  53.         )
  54.  
  55.     [2] => Array
  56.         (
  57.             [ifDescr] => LOOPBACK
  58.             [ifType] => ethernetCsmacd
  59.         )
  60.  
  61. )
  62. SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m]
  63. SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '19' ORDER BY port_id[0m]
  64. ..
  65.  
  66. >> Runtime for discovery module 'ports': 1.8800 seconds with 2128 bytes
  67. #### Unload disco module ports ####
  68.  
  69. Modules status: Global+ OS+ Device  
  70. #### Load disco module ports-stack ####
  71. SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '19'[0m]
  72. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ifStackStatus[0m]
  73. ifStackStatus = No Such Object available on this agent at this OID
  74.  
  75.  
  76.  
  77. >> Runtime for discovery module 'ports-stack': 0.9290 seconds with 640 bytes
  78. #### Unload disco module ports-stack ####
  79.  
  80. Modules status: Global+ OS+ Device  
  81. #### Load disco module entity-physical ####
  82.  
  83. Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalEntry[0m]
  84. entPhysicalEntry = No Such Object available on this agent at this OID
  85.  
  86.  entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
  87. entAliasMappingIdentifier = No Such Object available on this agent at this OID
  88.  
  89.  
  90. SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '19'[0m]
  91.  
  92. >> Runtime for discovery module 'entity-physical': 0.2790 seconds with 2952 bytes
  93. #### Unload disco module entity-physical ####
  94.  
  95. Modules status: Global+ OS+ Device  
  96. #### Load disco module processors ####
  97.  hrDevice: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrDevice[0m]
  98. hrDevice = No Such Object available on this agent at this OID
  99.  
  100. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrProcessorLoad[0m]
  101. hrProcessorLoad = No Such Object available on this agent at this OID
  102.  
  103. SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '19' AND `processor_type` != 'ucd-old'[0m]
  104. SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`  = '19'[0m]
  105.  
  106.  
  107. >> Runtime for discovery module 'processors': 3.1760 seconds with 36992 bytes
  108. #### Unload disco module processors ####
  109.  
  110. Modules status: Global+ OS+ Device  
  111. #### Load disco module mempools ####
  112. SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '19' AND `mempool_type` = 'cemp'[0m]
  113. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
  114. hpLocalMem = No Such Object available on this agent at this OID
  115.  
  116. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
  117. hpGlobalMem = No Such Object available on this agent at this OID
  118.  
  119. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrStorageEntry[0m]
  120. hrStorageEntry = No Such Object available on this agent at this OID
  121.  
  122. SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id`  = '19'[0m]
  123.  
  124.  
  125. >> Runtime for discovery module 'mempools': 1.1910 seconds with 24944 bytes
  126. #### Unload disco module mempools ####
  127.  
  128. Modules status: Global+ OS+ Device  
  129. #### Load disco module cisco-vrf-lite ####
  130. SQL[[0;33mSELECT * FROM vrf_lite_cisco WHERE device_id = '19' [0m]
  131.  
  132. >> Runtime for discovery module 'cisco-vrf-lite': 0.0000 seconds with 1592 bytes
  133. #### Unload disco module cisco-vrf-lite ####
  134.  
  135. Modules status: Global- OS- Device  Module [ cisco-mac-accounting ] disabled on os.
  136.  
  137. Modules status: Global- OS- Device  Module [ cisco-pw ] disabled on os.
  138.  
  139. Modules status: Global- OS- Device  Module [ cisco-vrf ] disabled on os.
  140.  
  141. Modules status: Global- OS- Device  Module [ cisco-cef ] disabled on os.
  142.  
  143. Modules status: Global- OS- Device  Module [ cisco-sla ] disabled on os.
  144.  
  145. Modules status: Global- OS- Device  Module [ cisco-cbqos ] disabled on os.
  146.  
  147. Modules status: Global- OS- Device  Module [ cisco-otv ] disabled on os.
  148.  
  149. Modules status: Global+ OS+ Device  
  150. #### Load disco module ipv4-addresses ####
  151. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntIfIndex[0m]
  152. ipAdEntIfIndex.* 1
  153. ipAdEntIfIndex.* 2
  154.  
  155. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m]
  156. *
  157.  
  158. SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '19' AND `ifIndex` = '1'[0m]
  159. SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '19' AND `ifIndex` = '1'[0m]
  160. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m]
  161. SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.1/32'[0m]
  162. sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m]
  163. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '1732' [0m]
  164. SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '1732'[0m]
  165. .SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAdEntNetMask.172.31.23.222[0m]
  166. *
  167.  
  168. SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '19' AND `ifIndex` = '2'[0m]
  169. SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '19' AND `ifIndex` = '2'[0m]
  170. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.31.23.222/24'[0m]
  171. SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.31.23.222/24'[0m]
  172. sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.31.23.222/24'[0m]
  173. SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.31.23.222' AND `ipv4_prefixlen` = '24' AND `port_id` = '1733' [0m]
  174. SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.31.23.222' AND `ipv4_prefixlen` = '24' AND `port_id` = '1733'[0m]
  175. .SQL[[0;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '19' OR `ports`.`device_id` IS NULL[0m]
  176.  
  177.  
  178. >> Runtime for discovery module 'ipv4-addresses': 0.1010 seconds with 31104 bytes
  179. #### Unload disco module ipv4-addresses ####
  180.  
  181. Modules status: Global+ OS+ Device  
  182. #### Load disco module ipv6-addresses ####
  183. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
  184. ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID
  185.  
  186. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
  187. .*.*.8.1.2 No Such Object available on this agent at this OID
  188.  
  189. SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '19' OR `ports`.`device_id` IS NULL[0m]
  190.  
  191.  
  192. >> Runtime for discovery module 'ipv6-addresses': 0.1660 seconds with 1120 bytes
  193. #### Unload disco module ipv6-addresses ####
  194.  
  195. Modules status: Global- OS- Device  Module [ route ] disabled on os.
  196.  
  197. Modules status: Global+ OS+ Device  
  198. #### Load disco module sensors ####
  199. Pre-cache poweralert: tlUpsSnmpCardSerialNum SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -m TRIPPLITE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 .1.3.6.1.4.1.850.100.1.1.4.0[0m]
  200. 2528AV0AC895C00702
  201.  
  202.  
  203. Array
  204. (
  205.     [poweralert_serial] => 2528AV0AC895C00702
  206. )
  207.  ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalDescr[0m]
  208. entPhysicalDescr = No Such Object available on this agent at this OID
  209.  
  210.  entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhysicalName[0m]
  211. entPhysicalName = No Such Object available on this agent at this OID
  212.  
  213.  entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorType[0m]
  214. entPhySensorType = No Such Object available on this agent at this OID
  215.  
  216.  entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorScale[0m]
  217. entPhySensorScale = No Such Object available on this agent at this OID
  218.  
  219.  entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorPrecision[0m]
  220. entPhySensorPrecision = No Such Object available on this agent at this OID
  221.  
  222.  entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 entPhySensorValue[0m]
  223. entPhySensorValue = No Such Object available on this agent at this OID
  224.  
  225.  
  226. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '19' AND `attrib_type` = 'ipmi_hostname' [0m]
  227. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'ipmi'[0m]
  228. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'ipmi'[0m]
  229. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'ipmi'[0m]
  230. SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'ipmi'[0m]
  231. Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  232.  
  233. Current: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  234.  
  235. Charge: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  236.  
  237. Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  238.  
  239. Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  240.  
  241. Frequency: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  242.  
  243. Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  244.  
  245. Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  246.  
  247. Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  248.  
  249. Runtime: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  250.  
  251. Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  252.  
  253. State: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  254.  
  255. Temperature: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  256.  
  257. Voltage: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  258.  
  259. Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '19' AND S.poller_type = 'snmp'[0m]
  260.  
  261.  
  262. >> Runtime for discovery module 'sensors': 0.8230 seconds with 14704 bytes
  263. #### Unload disco module sensors ####
  264.  
  265. Modules status: Global+ OS+ Device  
  266. #### Load disco module storage ####
  267. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m]
  268. eqliscsiVolumeEntry = No Such Object available on this agent at this OID
  269.  
  270. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrStorageEntry[0m]
  271. hrStorageEntry = No Such Object available on this agent at this OID
  272.  
  273. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dfEntry[0m]
  274. dfEntry = No Such Object available on this agent at this OID
  275.  
  276. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dskTable[0m]
  277. dskTable = No Such Object available on this agent at this OID
  278.  
  279. SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '19' AND `storage_type` != 'dsk'[0m]
  280. SQL[[0;33mSELECT * FROM `storage` WHERE `device_id`  = '19'[0m]
  281.  
  282.  
  283. >> Runtime for discovery module 'storage': 1.7780 seconds with 3376 bytes
  284. #### Unload disco module storage ####
  285.  
  286. Modules status: Global+ OS+ Device  
  287. #### Load disco module hr-device ####
  288. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrDeviceEntry[0m]
  289. hrDeviceEntry = No Such Object available on this agent at this OID
  290.  
  291. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 hrProcessorEntry[0m]
  292. hrProcessorEntry = No Such Object available on this agent at this OID
  293.  
  294. Array
  295. (
  296. )
  297. SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '19'[0m]
  298.  
  299.  
  300. >> Runtime for discovery module 'hr-device': 1.8480 seconds with 800 bytes
  301. #### Unload disco module hr-device ####
  302.  
  303. Modules status: Global+ OS+ Device  
  304. #### Load disco module discovery-protocols ####
  305.  CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 cdpCache[0m]
  306. cdpCache = No Such Object available on this agent at this OID
  307.  
  308. Array
  309. (
  310. )
  311.  LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m LLDP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 lldpRemoteSystemsData[0m]
  312. lldpRemoteSystemsData = No Such Object available on this agent at this OID
  313.  
  314. lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData ||  ||  ||
  315. Array
  316. (
  317. )
  318. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
  319. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  320.  
  321. Array
  322. (
  323. )
  324.  OSPF Discovery: enabled
  325. SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='19'[0m]
  326. SQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '19'[0m]
  327.  
  328.  
  329. >> Runtime for discovery module 'discovery-protocols': 1.0880 seconds with 4472 bytes
  330. #### Unload disco module discovery-protocols ####
  331.  
  332. Modules status: Global+ OS+ Device  
  333. #### Load disco module arp-table ####
  334. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
  335. ipNetToPhysicalPhysAddress[1] = 0
  336. ipNetToPhysicalPhysAddress[2] = 0
  337.  
  338. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m IP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
  339. ipNetToMediaPhysAddress[2][*] = bc:16:65:16:6c:6
  340. ipNetToMediaPhysAddress[2][*] = 0:14:f1:27:10:0
  341.  
  342. SQL[[0;33mSELECT * from `ipv4_mac` WHERE `device_id`='19' AND `context_name`=''[0m]
  343. SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '19' AND `ifIndex` = '1'[0m]
  344. eth0:
  345.  
  346. SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '19' AND `ifIndex` = '2'[0m]
  347. LOOPBACK:
  348. bc:16:65:16:6c:6 => 172.31.23.6
  349. 0:14:f1:27:10:0 => 172.31.23.254
  350.  
  351. SQL[[0;33mDELETE `ipv4_mac` FROM `ipv4_mac`
  352.  LEFT JOIN `ports` ON `ipv4_mac`.`port_id` = `ports`.`port_id`
  353.  LEFT JOIN `devices` ON `ipv4_mac`.`device_id` = `devices`.`device_id`
  354.  WHERE `ports`.`port_id` IS NULL OR `devices`.`device_id` IS NULL[0m]
  355.  
  356.  
  357. >> Runtime for discovery module 'arp-table': 0.1000 seconds with 28680 bytes
  358. #### Unload disco module arp-table ####
  359.  
  360. Modules status: Global- OS- Device  Module [ discovery-arp ] disabled on os.
  361.  
  362. Modules status: Global- OS- Device  Module [ junose-atm-vp ] disabled on os.
  363.  
  364. Modules status: Global+ OS+ Device  
  365. #### Load disco module bgp-peers ####
  366. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Oqvn -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 .1.3.6.1.2.1.15.2[0m]
  367. No Such Object available on this agent at this OID
  368.  
  369. No BGP on hostPeers :
  370. SQL[[0;33mSELECT * FROM bgpPeers WHERE device_id = '19' AND (context_name = '' OR context_name IS NULL)[0m]
  371.  
  372.  
  373. >> Runtime for discovery module 'bgp-peers': 0.9280 seconds with 2672 bytes
  374. #### Unload disco module bgp-peers ####
  375.  
  376. Modules status: Global+ OS+ Device  
  377. #### Load disco module vlans ####
  378. SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '19'[0m]
  379. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
  380. dot1dBasePortIfIndex = No Such Object available on this agent at this OID
  381.  
  382. IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
  383. No Such Object available on this agent at this OID
  384.  
  385.  
  386.  
  387. >> Runtime for discovery module 'vlans': 0.9330 seconds with 4456 bytes
  388. #### Unload disco module vlans ####
  389.  
  390. Modules status: Global- OS- Device  Module [ vmware-vminfo ] disabled on os.
  391.  
  392. Modules status: Global- OS- Device  Module [ libvirt-vminfo ] disabled on os.
  393.  
  394. Modules status: Global- OS- Device  Module [ toner ] disabled on os.
  395.  
  396. Modules status: Global+ OS+ Device  
  397. #### Load disco module ucd-diskio ####
  398. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 diskIOEntry[0m]
  399. diskIOEntry = No Such Object available on this agent at this OID
  400.  
  401. Array
  402. (
  403. )
  404. SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id`  = '19'[0m]
  405.  
  406.  
  407. >> Runtime for discovery module 'ucd-diskio': 0.3400 seconds with 736 bytes
  408. #### Unload disco module ucd-diskio ####
  409.  
  410. Modules status: Global- OS- Device  Module [ applications ] disabled on os.
  411.  
  412. Modules status: Global+ OS+ Device  
  413. #### Load disco module services ####
  414.  
  415. >> Runtime for discovery module 'services': 0.0000 seconds with 352 bytes
  416. #### Unload disco module services ####
  417.  
  418. Modules status: Global+ OS+ Device  
  419. #### Load disco module stp ####
  420. SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '19'[0m]
  421. SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
  422. No Such Object available on this agent at this OID
  423.  
  424.  
  425.  
  426. >> Runtime for discovery module 'stp': 0.0120 seconds with 3648 bytes
  427. #### Unload disco module stp ####
  428.  
  429. Modules status: Global+ OS+ Device  
  430. #### Load disco module ntp ####
  431.  
  432. >> Runtime for discovery module 'ntp': 6.3890 seconds with 144 bytes
  433. #### Unload disco module ntp ####
  434.  
  435. Modules status: Global- OS- Device  Module [ loadbalancers ] disabled on os.
  436.  
  437. Modules status: Global- OS- Device  Module [ mef ] disabled on os.
  438.  
  439. Modules status: Global+ OS+ Device  
  440. #### Load disco module wireless ####
  441. Attempting to initialize OS: poweralert
  442. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='ap-count'[0m]
  443. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='clients'[0m]
  444. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='quality'[0m]
  445. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='capacity'[0m]
  446. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='utilization'[0m]
  447. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='rate'[0m]
  448. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='ccq'[0m]
  449. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='snr'[0m]
  450. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='mse'[0m]
  451. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='rssi'[0m]
  452. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='power'[0m]
  453. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='noise-floor'[0m]
  454. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='error-ratio'[0m]
  455. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='error-rate'[0m]
  456. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='frequency'[0m]
  457. SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='19' AND `sensor_class`='distance'[0m]
  458.  
  459. >> Runtime for discovery module 'wireless': 0.0050 seconds with 132808 bytes
  460. #### Unload disco module wireless ####
  461.  
  462. Modules status: Global+ OS+ Device  
  463. #### Load disco module fdb-table ####
  464. SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '19'[0m]
  465. SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '19'[0m]
  466. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1qTpFdbPort[0m]
  467. dot1qTpFdbPort = No Such Object available on this agent at this OID
  468.  
  469. SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/poweralert udp:HOSTNAME:161 dot1dTpFdbPort[0m]
  470. dot1dTpFdbPort = No Such Object available on this agent at this OID
  471.  
  472.  
  473.  
  474. >> Runtime for discovery module 'fdb-table': 1.8240 seconds with 1848 bytes
  475. #### Unload disco module fdb-table ####
  476.  
  477. SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '19' AND `attrib_type` = 'poll_mib' [0m]
  478. SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='17.931' WHERE `device_id` = '19'[0m]
  479. Discovered in 17.931 seconds
  480.  
  481. SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','172.31.23.222','1505343527.0471','18.06','1','DIT-LibreNMS.cchnl.hnl\n')[0m]
  482. ./discovery.php 172.31.23.222 2017-09-13 12:59:05 - 1 devices discovered in 18.06 secs
  483. SNMP: Get[8/0.14s] Walk [29/14.12s]
  484. MySQL: Cell[14/0.01s] Row[7/0.00s] Rows[57/0.03s] Column[1/0.00s] Update[5/0.12s] Insert[2/0.07s] Delete[0/0.00s]
  485.