SQL[[1;33mselect `migration` from `migrations` order by `id` desc limit 1 [0;33m[][0m 1.
SQL[[1;33mselect count(*) as aggregate from `migrations` [0;33m[][0m 1.
SQL[[1;33mselect version() [0;33m[][0m 1.
===========================================
===========================================
Component |
--------- |
LibreNMS | 22.10.0
DB Schema | 2022_09_03_091314_update_ports_adsl_table_with_defaults
PHP | 8.0.
Python | 3.10.
Database | MariaDB 10.9.3-MariaDB-1:10.9.
RRDTool | 1.7.
SNMP | 5.9.
===========================================
DEBUG!
===========================================
DEBUG!
Updating os_def.
SQL[[1;33mSELECT * FROM `devices` WHERE disabled = 0 AND `hostname` LIKE '192.168.100.1' ORDER BY device_id DESC [0;33m[][0m 2.
SQL[[1;33mselect * from `devices` where `device_id` = ? limit 1 [0;33m[12][0m 0.
SQL[[1;33mselect * from `devices_attribs` where `devices_attribs`.`device_id` = ? and `devices_attribs`.`device_id` is not null [0;33m[12][0m 0.
192.168.100.1 12 linux [FPING] '/usr/sbin/fping' '-e' '-q' '-c' '3' '-p' '500' '-t' '500' '-O' '0' '192.168.100.
response: xmt/rcv/%loss = 3/3/0%, min/avg/max = 0.564/0.615/0.
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.
SNMPv2-MIB::sysObjectID.0 = NET-SNMP-MIB::netSnmpAgentOIDs.
Modules status:
OS
Device
OS
Device
#### Load disco module core
Attempting to initialize OS:
Attempting to initialize Group OS:
OS initialized:
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' '-On' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysObjectID.0' 'SNMPv2-MIB::sysDescr.0' 'SNMPv2-MIB::sysName.
.
.*.*.0 = .*.4.1.
.
.*.*.0 = Linux UDM-SE 4.19.152-ui-alpine #4.19.152 SMP Mon Aug 1 14:24:56 CST 2022
.
.*.*.0 =
| Linux UDM-SE 4.19.152-ui-alpine #4.19.152 SMP Mon Aug 1 14:24:56 CST 2022 aarch64 | .1.3.6.1.4.1.8072.3.2.10
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ubnt' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'UBNT-AFLTU-MIB::afLTUFirmwareVersion.
UBNT-AFLTU-MIB::afLTUFirmwareVersion.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/haproxy' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
EXCELIANCE-MIB::alProductName = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/arris' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.1166.1.621.14.2.
SNMPv2-SMI::enterprises.1166.1.6* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.7890.1.101.
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.3.1.2.6.100.105.115.116.114.
NET-SNMP-EXTEND-MIB::nsExtendOutputFull[distro] = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/cirpack' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.9193.1.
SNMPv2-SMI::enterprises.9193.1.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line.
NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[distro] = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/ddn' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SFA-INFO::systemName.
SFA-INFO::systemName.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/synology' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'SYNOLOGY-SYSTEM-MIB::systemStatus.
SYNOLOGY-SYSTEM-MIB::systemStatus.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/synology' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.
HOST-RESOURCES-MIB::hrSystemInitialLoadParameters.0 = "pci=pcie_bus_perf console=ttyS0,115200 net.ifnames=0 sysid=ea2c boot_carrier=4
"
"
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.5.0.11.
SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.12.1.16.
SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/endrun' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.13827.14.1.16.
SNMPv2-SMI::enterprises.138*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/eltek' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.12148.10.2.6.
SNMPv2-SMI::enterprises.12*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/extrahop' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
EXTRAHOP-MIB::extrahopInfoVersionString = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.2.1.3.7.118.101.114.115.105.111.
NET-SNMP-EXTEND-MIB::nsExtendArgs[version] = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/checkpoint' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'CHECKPOINT-MIB::osName.
CHECKPOINT-MIB::osName.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hikvision' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.39165.1.1.
SNMPv2-SMI::enterprises.39* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/huawei' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2011.6.164.1.1.1.4.
SNMPv2-SMI::enterprises.2*.* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/infinera' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'CORIANT-GROOVE-MIB::softwareloadSwloadProduct.
CORIANT-GROOVE-MIB::softwareloadSwloadProduct[1] = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
HOST-RESOURCES-MIB::hrSWInstalledName = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'UPS-MIB::upsIdentAgentSoftwareVersion.
UPS-MIB::upsIdentAgentSoftwareVersion.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.7890.1.101.
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/orvaldi' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.21111.1.1.1.6.
SNMPv2-SMI::enterprises.21*.6.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '1.3.6.1.4.1.4515.1.3.6.1.1.1.2.
SNMPv2-SMI::enterprises.45*.*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/carel' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'CAREL-ug40cdz-MIB::roomTemp.
CAREL-ug40cdz-MIB::roomTemp.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/gandi' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'GANDI-MIB::rxCounter.
GANDI-MIB::rxCounter.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/primekey' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
PRIMEKEY-APPLIANCE-MIB::pkAVersion = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/osnexus' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'QUANTASTOR-SYS-STATS::storageSystem-ProductId.
QUANTASTOR-SYS-STATS::storageSystem-ProductId[0] = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/unitrends' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.21865.1.6.1.
SNMPv2-SMI::enterprises.218*.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/toshiba' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'UPS-MIB::upsIdentAgentSoftwareVersion.
UPS-MIB::upsIdentAgentSoftwareVersion.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/teltonika' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.48690.1.3.
SNMPv2-SMI::enterprises.486* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/checkpoint' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'CHECKPOINT-MIB::osName.
CHECKPOINT-MIB::osName.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.7890.1.101.
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/wisi' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.7465.20.2.9.1.2.1.3.1.
SNMPv2-SMI::enterprises.74*.*.1.2 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/wti' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'WTI-MPC-MIB::environmentUnitName.
WTI-MPC-MIB::environmentUnitName[1] = No Such Object available on this agent at this
OS: Linux
Attempting to initialize OS:
Attempting to initialize Group OS:
OS initialized:
>> Runtime for discovery module 'core': 3.0100 seconds with -211656
>> [0;36mSNMP[0m: [37/2.93s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module core
Modules status:
OS
Device
OS
Device
#### Load disco module os
Yaml location
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'SNMPv2-MIB::sysLocation.
Jon's
SQL[[1;33mselect * from `locations` where (`location` = ?) limit 1 [0;33m["Jon's Office"][0m 2.
::query() failed: DNS request failed: The domain name referenced in the query does not exist.
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-m' 'SNMPv2-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'sysContact.
Jon
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/dell' 'udp:HOSTNAME:161' 'MIB-Dell-10892::chassisModelName.1' 'MIB-Dell-10892::chassisServiceTagName.
MIB-Dell-10892::chassisModelName.1 = No Such Object available on this agent at this
MIB-Dell-10892::chassisServiceTagName.1 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hp' 'udp:HOSTNAME:161' 'CPQSINFO-MIB::cpqSiProductName.0' 'CPQSINFO-MIB::cpqSiSysSerialNum.
CPQSINFO-MIB::cpqSiProductName.0 = No Such Object available on this agent at this
CPQSINFO-MIB::cpqSiSysSerialNum.0 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OUQ' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' 'udp:HOSTNAME:161' 'SUPERMICRO-SD5-MIB::mbProductName.1' 'SUPERMICRO-SD5-MIB::mbSerialNumber.
SUPERMICRO-SD5-MIB::mbProductName.1 = No Such Object available on this agent at this
SUPERMICRO-SD5-MIB::mbSerialNumber.1 = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."distro"' '.1.3.6.1.4.1.2021.7890.1.3.1.1.6.100.105.115.116.114.111' '.1.3.6.1.4.1.2021.7890.1.101.
NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[distro] = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78*.*.* = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."hardware"' '.1.3.6.1.4.1.2021.7890.2.4.1.2.8.104.97.114.100.119.97.114.101.1' '.1.3.6.1.4.1.2021.7890.2.101.
NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[hardware] = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78*.*.*.114.101.1 = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161' 'NET-SNMP-EXTEND-MIB::nsExtendOutput1Line."serial"' '.1.3.6.1.4.1.2021.7890.4.4.1.2.6.115.101.114.105.97.108.1' '.1.3.6.1.4.1.2021.7890.4.101.
NET-SNMP-EXTEND-MIB::nsExtendOutput1Line[serial] = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78*.*.*.1 = No Such Object available on this agent at this
UCD-SNMP-MIB::ucdavis.78* = No Such Object available on this agent at this
Location: Jon's
Hardware: Generic ARMv8
OS Version: 4.19.
OS
Serial:
Serial:
>> Runtime for discovery module 'os': 0.7490 seconds with 231480
>> [0;36mSNMP[0m: [9/0.64s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module os
Modules status:
OS
Device
OS
Device
#### Load disco module ports
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifDescr = No Such Object available on this agent at this
Invalid snmp_walk() data = ifDescr = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifName = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifAlias = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifType = No Such Object available on this agent at this
Invalid snmp_walk() data = ifType = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifOperStatus = No Such Object available on this agent at this
Invalid snmp_walk() data = ifOperStatus = No Such Object available on this agent at this
array
)
)
SQL[[1;33mSELECT * FROM `ports` WHERE `device_id` = ? ORDER BY port_id [0;33m[12][0m 3.
>> Runtime for discovery module 'ports': 0.2170 seconds with 2328
>> [0;36mSNMP[0m: [5/0.21s] [1;33mMySQL[0m: [1/0.03s] [0;32mRRD[0m: [0/0.
#### Unload disco module ports
Modules status:
OS
Device
OS
Device
#### Load disco module ports-stack
SQL[[1;33mSELECT * FROM `ports_stack` WHERE `device_id` = '12' [0;33m[][0m 1.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IF-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ifStackStatus = No more variables left in this MIB View (It is past the end of the MIB
>> Runtime for discovery module 'ports-stack': 0.0380 seconds with 288
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module ports-stack
Modules status:
OS
Device
OS
Device
Module [ xdsl ] disabled
Modules status:
OS
Device
OS
Device
#### Load disco module entity-physical
Caching OIDs: entPhysicalEntrySNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
entPhysicalEntry = No more variables left in this MIB View (It is past the end of the MIB
MIB search path:
Cannot find module (CISCO-ENTITY-VENDORTYPE-OID-MIB): At line 12 in
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
adapterInfoTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
enclosureTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
physicalDriveTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
bbuTable = No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mSELECT * FROM `entPhysical` WHERE `device_id` = ? [0;33m[12][0m 2.
>> Runtime for discovery module 'entity-physical': 0.2140 seconds with 1968
>> [0;36mSNMP[0m: [5/0.20s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module entity-physical
Modules status:
OS
Device
OS
Device
#### Load disco module entity-state
SQL[[1;33mSELECT entPhysical_id, entPhysicalIndex FROM entPhysical WHERE device_id=? [0;33m[12][0m 1.
>> Runtime for discovery module 'entity-state': 0.0030 seconds with 584
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module entity-state
Modules status:
OS
Device
OS
Device
Module [ isis ] disabled
Modules status:
OS
Device
OS
Device
#### Load disco module processors
No YAML Discovery data.
Host Resources: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
hrProcessorLoad = No more variables left in this MIB View (It is past the end of the MIB
UCD Resources: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Ovq' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.2021.11.11.
No Such Object available on this agent at this
SQL[[1;33mSELECT * FROM `processors` WHERE `device_id`=? [0;33m[12][0m 1.
SQL[[1;33mDELETE T FROM `processors` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.
>> Runtime for discovery module 'processors': 0.1190 seconds with 119224
>> [0;36mSNMP[0m: [2/0.10s] [1;33mMySQL[0m: [2/0.03s] [0;32mRRD[0m: [0/0.
#### Unload disco module processors
Modules status:
OS
Device
OS
Device
#### Load disco module mempools
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
hrStorageTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUv' '-m' 'HOST-RESOURCES-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'hrMemorySize.
No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'memTotalSwap.0' 'memAvailSwap.0' 'memTotalReal.0' 'memAvailReal.0' 'memBuffer.0' 'memCached.0' 'memSysAvail.
memTotalSwap.0 = No Such Object available on this agent at this
memAvailSwap.0 = No Such Object available on this agent at this
memTotalReal.0 = No Such Object available on this agent at this
memAvailReal.0 = No Such Object available on this agent at this
memBuffer.0 = No Such Object available on this agent at this
memCached.0 = No Such Object available on this agent at this
memSysAvail.0 = No Such Object available on this agent at this
SQL[[1;33mselect * from `mempools` where `mempools`.`device_id` = ? and `mempools`.`device_id` is not null [0;33m[12][0m 2.
>> Runtime for discovery module 'mempools': 0.1090 seconds with 34472
>> [0;36mSNMP[0m: [2/0.06s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module mempools
Modules status:
OS
Device
OS
Device
Module [ cisco-vrf-lite ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-mac-accounting ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-pw ] disabled
Modules status:
OS
Device
OS
Device
Module [ vrf ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-cef ] disabled
Modules status:
OS
Device
OS
Device
Module [ slas ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-cbqos ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-otv ] disabled
Modules status:
OS
Device
OS
Device
Module [ cisco-qfp ] disabled
Modules status:
OS
Device
OS
Device
#### Load disco module ipv4-addresses
SQL[[1;33mselect * from `vrf_lite_cisco` where `vrf_lite_cisco`.`device_id` = ? and `vrf_lite_cisco`.`device_id` is not null [0;33m[12][0m 1.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osq' '-m' 'IP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
ipAdEntIfIndex No Such Object available on this agent at this
Invalid snmp_walk() data = ipAdEntIfIndex No Such Object available on this agent at this
SQL[[1;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[12][0m 2.
>> Runtime for discovery module 'ipv4-addresses': 0.0510 seconds with 26968
>> [0;36mSNMP[0m: [1/0.04s] [1;33mMySQL[0m: [2/0.04s] [0;32mRRD[0m: [0/0.
#### Unload disco module ipv4-addresses
Modules status:
OS
Device
OS
Device
#### Load disco module ipv6-addresses
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUt' 'udp:HOSTNAME:161' 'IP-MIB::ipAddressIfIndex.
IP-MIB::ipAddressIfIndex[ipv6] = No Such Object available on this agent at this
SNMP query failed. Exit Code: 0 Empty: false Bad String: No Such Object available on this agent at this
SNMP failed walking IP-MIB::ipAddressIfIndex.ipv6 of IP-MIB::ipAddressIfIndex.ipv6,IP-MIB::ipAddressOrigin.ipv6,IP-MIB::ipAddressPrefix.ipv6 aborting.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-Ln' '-m' 'IPV6-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
.
.*.*.8.1.2 No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = ? OR `ports`.`device_id` IS NULL [0;33m[12][0m 1.
>> Runtime for discovery module 'ipv6-addresses': 0.1170 seconds with 1616
>> [0;36mSNMP[0m: [2/0.11s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module ipv6-addresses
Modules status:
OS
Device
OS
Device
#### Load disco module route
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'IP-FORWARD-MIB::inetCidrRouteNumber.
.
.*.*.6.0 No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IP-FORWARD-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'inetCidrRouteNumber.0' 'ipCidrRouteNumber.
inetCidrRouteNumber.0 = No Such Object available on this agent at this
ipCidrRouteNumber.0 = No Such Object available on this agent at this
SQL[[1;33mselect now() as now [0;33m[][0m 1.
SQL[[1;33mselect * from `route` where `device_id` = ? [0;33m[12][0m 1.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'RFC1213-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.2.1.4.
ipRouteTable = No Such Object available on this agent at this
Routing
array
)
)
RFC1213 SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'MPLS-L3VPN-STD-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
mplsL3VpnVrfPerfCurrNumRoutes = No Such Object available on this agent at this
Reporting disabled by user
mplsL3VpnVrfRteTable SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'MPLS-L3VPN-STD-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
mplsL3VpnVrfRteTable = No Such Object available on this agent at this
Processing:
Processing:
>> Runtime for discovery module 'route': 0.2420 seconds with 6448
>> [0;36mSNMP[0m: [2/0.11s] [1;33mMySQL[0m: [2/0.03s] [0;32mRRD[0m: [0/0.
#### Unload disco module route
Modules status:
OS
Device
OS
Device
#### Load disco module sensors
Pre-cache linux: RaspberryPi SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.
nsExtendOutLine."raspberry" = No more variables left in this MIB View (It is past the end of the MIB
ups-nut SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.
nsExtendOutLine."ups-nut" = No more variables left in this MIB View (It is past the end of the MIB
array
'raspberry_pi_sensors'
array
),
),
'ups_nut_sensors'
array
),
)
),
)
Caching data: sensors SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
adapterPropertiesTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
bbuTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
physicalDriveTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
enclosurePowerSupplyTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
enclosureFanTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsa' '-Ih' '-m' 'LSI-MegaRAID-SAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
enclosureAlarmTable = No more variables left in this MIB View (It is past the end of the MIB
ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'ENTITY-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
entPhysicalDescr = No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",12,"ipmi"][0m 3.
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",12,"ipmi"][0m 1.
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",12,"ipmi"][0m 1.
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",12,"ipmi"][0m 1.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OteQUsb' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'nsExtendOutLine.
nsExtendOutLine.*.*.*.116.111.114 = No more variables left in this MIB View (It is past the end of the MIB
Airflow: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["airflow",12,"snmp"][0m 3.
Current: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["current",12,"snmp"][0m 1.
Charge: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["charge",12,"snmp"][0m 2.
Dbm: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["dbm",12,"snmp"][0m 1.
Fanspeed: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'LM-SENSORS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
.
.*.4.1.2*.1.2 No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.
.
.*.4.1.108*.1.1.3 No more variables left in this MIB View (It is past the end of the MIB
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["fanspeed",12,"snmp"][0m 3.
Frequency: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["frequency",12,"snmp"][0m 1.
Humidity: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["humidity",12,"snmp"][0m 1.
Load: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["load",12,"snmp"][0m 3.
Loss: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["loss",12,"snmp"][0m 1.
Power: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power",12,"snmp"][0m 1.
Power_consumed: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_consumed",12,"snmp"][0m 1.
Power_factor: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["power_factor",12,"snmp"][0m 1.
Runtime: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["runtime",12,"snmp"][0m 2.
Signal: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["signal",12,"snmp"][0m 1.
State: Dynamic Discovery
array
'data'
array
0
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.4.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'descr' =>
'state_name' =>
'states'
array
0
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
),
),
1
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.5.1.3.{{ $index
'group' => 'Enclosure {{ $enclosureId-EPST
'descr' => 'Powersupply {{ $powerSupplyID
'state_name' =>
'states'
array
0
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
2
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
3
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
4
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
5
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
6
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
7
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
),
),
2
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.3.1.3.{{ $index
'group' => 'Enclosure {{ $enclosureId
'descr' => 'FAN {{ $fanID
'state_name' =>
'states'
array
0
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
2
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
3
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
4
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
5
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
6
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
7
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
),
),
3
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.5.7.{{ $index
'group' => 'Enclosure {{ $enclosureId-EAT
'descr' =>
'state_name' =>
'states'
array
0
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
2
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
3
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
4
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
5
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
6
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
7
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
),
),
4
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20.{{ $index
'group' => 'RAID Controller {{ $adpID
'descr' => 'BBU
'state_name' =>
'states'
array
0
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
2
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
3
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
),
),
5
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27.{{ $index
'group' => 'RAID Controller {{ $adpID
'descr' => 'BBU
'state_name' =>
'states'
array
0
array
'descr' => 'not
'graph' =>
'value' =>
'generic' =>
),
),
1
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
2
array
'descr' =>
'graph' =>
'value' =>
'generic' =>
),
),
),
),
)
),
),
),
),
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["state",12,"snmp"][0m 1.
Count: Dynamic Discovery
array
'data'
array
0
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.18.{{ $index
'index' => 'vdsum.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'descr' => 'Virtual
),
),
1
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.19.{{ $index
'index' => 'vdfail.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'warn_limit' =>
'descr' => 'Virtual disk
),
),
2
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.23.{{ $index
'index' => 'criticaldisks.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'warn_limit' =>
'descr' => 'Critical
),
),
3
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.24.{{ $index
'index' => 'faileddisks.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'warn_limit' =>
'descr' => 'Failed
),
),
)
),
),
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["count",12,"snmp"][0m 1.
Temperature: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-m' 'LM-SENSORS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
.
.*.4.1.2*.1.2 No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqve' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.9.114.97.115.112.98.101.114.114.121.
No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-Osqn' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.
.
.*.4.1.108*.1.1.3 No more variables left in this MIB View (It is past the end of the MIB
Dynamic Discovery
array
'data'
array
0
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.2.1.42.{{ $index
'index' => 'controllertemp.{{ $index
'group' => 'RAID Controller {{ $adapterID-APT
'descr' =>
),
),
1
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16.{{ $index
'index' => 'bbutemp.{{ $index
'group' => 'RAID Controller {{ $adpID
'descr' =>
),
),
2
array
'oid' =>
'value' =>
'num_oid' => '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36.{{ $index
'index' => 'slot.{{ $index
'group' => 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId
'descr' => '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber
),
),
)
),
),
)
Data
array
)
)
Data
array
)
)
Data
array
)
)
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["temperature",12,"snmp"][0m 3.
Tv_signal: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["tv_signal",12,"snmp"][0m 1.
Bitrate: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["bitrate",12,"snmp"][0m 1.
Voltage: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'LM-SENSORS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
.
.*.4.1.2*.1.2 No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OsqnU' '-m' 'SUPERMICRO-HEALTH-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/supermicro' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.10876.2.1.1.1.1.
.
.*.4.1.108*.1.1.3 No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Osqnv' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' '.1.3.6.1.4.1.8072.1.3.2.4.1.2.7.117.112.115.45.110.117.116.
No Such Object available on this agent at this
array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["voltage",12,"snmp"][0m 3.
Snr: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["snr",12,"snmp"][0m 1.
Pressure: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["pressure",12,"snmp"][0m 2.
Cooling: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["cooling",12,"snmp"][0m 2.
Delay: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["delay",12,"snmp"][0m 2.
Quality_factor: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["quality_factor",12,"snmp"][0m 1.
Chromatic_dispersion: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["chromatic_dispersion",12,"snmp"][0m 1.
Ber: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["ber",12,"snmp"][0m
Eer: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["eer",12,"snmp"][0m 1.
Waterflow: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["waterflow",12,"snmp"][0m 1.
Percent: array
)
)
SQL[[1;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class=? AND S.device_id = D.device_id AND D.device_id = ? AND S.poller_type = ? [0;33m["percent",12,"snmp"][0m 1.
>> Runtime for discovery module 'sensors': 1.3020 seconds with 21752
>> [0;36mSNMP[0m: [24/1.16s] [1;33mMySQL[0m: [34/0.74s] [0;32mRRD[0m: [0/0.
#### Unload disco module sensors
Modules status:
OS
Device
OS
Device
#### Load disco module storage
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'IBM-AIX-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
Exitcode:
MIB search path:
Cannot find module (IBM-AIX-MIB): At line 12 in
aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) ->
MIB search path:
Cannot find module (IBM-AIX-MIB): At line 12 in
aixFsTableEntry: Unknown Object Identifier (Sub-id not found: (top) ->
aix_filesystem : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'DATA-DOMAIN-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/datadomain' 'udp:HOSTNAME:161'
fileSystemSpaceTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
Exitcode:
MIB search path:
Cannot find module (FREENAS-MIB): At line 12 in
datasetTable: Unknown Object Identifier (Sub-id not found: (top) ->
MIB search path:
Cannot find module (FREENAS-MIB): At line 12 in
datasetTable: Unknown Object Identifier (Sub-id not found: (top) ->
SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '12' AND `storage_type` != 'dataset' [0;33m[][0m 2.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'FREENAS-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
Exitcode:
MIB search path:
Cannot find module (FREENAS-MIB): At line 12 in
zpoolTable: Unknown Object Identifier (Sub-id not found: (top) ->
MIB search path:
Cannot find module (FREENAS-MIB): At line 12 in
zpoolTable: Unknown Object Identifier (Sub-id not found: (top) ->
SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '12' AND `storage_type` != 'zpool' [0;33m[][0m 2.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CPQHOST-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/hp' 'udp:HOSTNAME:161'
cpqHoFileSysEntry = No more variables left in this MIB View (It is past the end of the MIB
HPE ILO4 hrStorage : SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-SNMP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
dskTable = No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mSELECT `storage_descr` FROM `storage` WHERE `device_id` = '12' AND `storage_type` != 'dsk' [0;33m[][0m 1.
array
)
)
SQL[[1;33mSELECT * FROM `storage` WHERE `device_id` = '12' [0;33m[][0m 1.
>> Runtime for discovery module 'storage': 0.2420 seconds with 1024
>> [0;36mSNMP[0m: [5/0.18s] [1;33mMySQL[0m: [4/0.07s] [0;32mRRD[0m: [0/0.
#### Unload disco module storage
Modules status:
OS
Device
OS
Device
#### Load disco module hr-device
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
hrDeviceTable = No more variables left in this MIB View (It is past the end of the MIB
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
hrProcessorTable = No more variables left in this MIB View (It is past the end of the MIB
array
)
)
SQL[[1;33mSELECT * FROM `hrDevice` WHERE `device_id` = '12' [0;33m[][0m 1.
>> Runtime for discovery module 'hr-device': 0.0700 seconds with -216
>> [0;36mSNMP[0m: [2/0.07s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module hr-device
Modules status:
OS
Device
OS
Device
#### Load disco module discovery-protocols
CISCO-CDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'CISCO-CDP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
Exitcode:
MIB search path:
Cannot find module (CISCO-CDP-MIB): At line 12 in
cdpCache: Unknown Object Identifier (Sub-id not found: (top) ->
MIB search path:
Cannot find module (CISCO-CDP-MIB): At line 12 in
cdpCache: Unknown Object Identifier (Sub-id not found: (top) ->
LLDP-MIB: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'LLDP-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
lldpRemTable = No Such Object available on this agent at this
OSPF Discovery: SQL[[1;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`=? [0;33m[12][0m 2.
SQL[[1;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = ? [0;33m[12][0m 1.
SQL[[1;33mDELETE T FROM `links` T LEFT JOIN `devices` ON `devices`.`device_id` = T.`local_device_id` WHERE `devices`.`device_id` IS NULL [0;33m[][0m 1.
0 orphaned links
>> Runtime for discovery module 'discovery-protocols': 0.1050 seconds with 176
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [3/0.05s] [0;32mRRD[0m: [0/0.
#### Unload disco module discovery-protocols
Modules status:
OS
Device
OS
Device
#### Load disco module arp-table
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
IP-MIB::ipNetToPhysicalPhysAddress = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-M' '/opt/librenms/mibs' '-v2c' '-c' 'COMMUNITY' '-OQXUte' 'udp:HOSTNAME:161'
IP-MIB::ipNetToMediaPhysAddress = No Such Object available on this agent at this
SQL[[1;33mSELECT * from `ipv4_mac` WHERE `device_id`=? AND `context_name`=? [0;33m[12,""][0m 1.
SQL[[1;33mDELETE T FROM `ipv4_mac` T LEFT JOIN `ports` ON `ports`.`port_id` = T.`port_id` LEFT JOIN `devices` ON `devices`.`device_id` = T.`device_id` WHERE `ports`.`port_id` IS NULL AND `devices`.`device_id` IS NULL [0;33m[][0m 1.
>> Runtime for discovery module 'arp-table': 0.1500 seconds with -296
>> [0;36mSNMP[0m: [2/0.14s] [1;33mMySQL[0m: [2/0.03s] [0;32mRRD[0m: [0/0.
#### Unload disco module arp-table
Modules status:
OS
Device
OS
Device
#### Load disco module discovery-arp
SQL[[1;33m
SQL[[1;33m
SELECT
FROM ipv4_mac as m, ports as
WHERE m.port_id = i.
AND i.device_id =
AND i.deleted =
AND NOT EXISTS
SELECT * FROM ipv4_addresses
WHERE a.ipv4_address = m.
)
)
GROUP BY
ORDER BY
[0;33m[12][0m 2.
>> Runtime for discovery module 'discovery-arp': 0.0040 seconds with 80
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [1/0.03s] [0;32mRRD[0m: [0/0.
#### Unload disco module discovery-arp
Modules status:
OS
Device
OS
Device
Module [ junose-atm-vp ] disabled
Modules status:
OS-
Device
OS-
Device
Module [ bgp-peers ] disabled on
Modules status:
OS
Device
OS
Device
#### Load disco module vlans
SQL[[1;33mSELECT * FROM `vlans` WHERE `device_id` = ? [0;33m[12][0m
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
dot1dBasePortIfIndex = No Such Object available on this agent at this
Invalid snmp_walk() data = dot1dBasePortIfIndex = No Such Object available on this agent at this
IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m'/usr/bin/snmpget' '-v2c' '-c' 'COMMUNITY' '-Oqv' '-m' 'IEEE8021-Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161' 'dot1qVlanVersionNumber.
No Such Object available on this agent at this
>> Runtime for discovery module 'vlans': 0.1400 seconds with 112
>> [0;36mSNMP[0m: [2/0.13s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module vlans
Modules status:
OS+
Device
OS+
Device
#### Load disco module vmware-vminfo
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' '+VMWARE-ROOT-MIB:VMWARE-VMINFO-MIB' '-M' '/opt/librenms/mibs:/opt/librenms/mibs/vmware' 'udp:HOSTNAME:161'
vmwVmTable = No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mSELECT id, vmwVmVMID, vmwVmDisplayName FROM vminfo WHERE device_id = '12' AND vm_type='vmware' [0;33m[][0m 2.
>> Runtime for discovery module 'vmware-vminfo': 0.0960 seconds with -424
>> [0;36mSNMP[0m: [1/0.09s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module vmware-vminfo
Modules status:
OS+
Device
OS+
Device
#### Load disco module libvirt-vminfo
>> Runtime for discovery module 'libvirt-vminfo': 0.0030 seconds with 80
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module libvirt-vminfo
Modules status:
OS
Device
OS
Device
#### Load disco module printer-supplies
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'Printer-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
prtMarkerSuppliesLevel = No more variables left in this MIB View (It is past the end of the MIB
Tray Paper Level: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'Printer-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
prtInputName = No more variables left in this MIB View (It is past the end of the MIB
SQL[[1;33mselect * from `printer_supplies` where `printer_supplies`.`device_id` = ? and `printer_supplies`.`device_id` is not null [0;33m[12][0m 2.
>> Runtime for discovery module 'printer-supplies': 0.0980 seconds with 31552
>> [0;36mSNMP[0m: [2/0.09s] [1;33mMySQL[0m: [1/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module printer-supplies
Modules status:
OS
Device
OS
Device
#### Load disco module ucd-diskio
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'UCD-DISKIO-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
diskIOEntry = No more variables left in this MIB View (It is past the end of the MIB
array
)
)
SQL[[1;33mSELECT * FROM `ucd_diskio` where `device_id` = '12' [0;33m[][0m 1.
>> Runtime for discovery module 'ucd-diskio': 0.0310 seconds with 160
>> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [1/0.01s] [0;32mRRD[0m: [0/0.
#### Unload disco module ucd-diskio
Modules status:
OS+
Device
OS+
Device
#### Load disco module applications
Applications: SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUs' '-m' 'NET-SNMP-EXTEND-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
nsExtendStatus = No more variables left in this MIB View (It is past the end of the MIB
Available:
Available:
Checking
SQL[[1;33mSELECT `app_type`,`discovered` FROM `applications` WHERE `device_id`=? ORDER BY `app_type` [0;33m[12][0m 1.
SQL[[1;33mDELETE T FROM `application_metrics` T LEFT JOIN `applications` ON `applications`.`app_id` = T.`app_id` WHERE `applications`.`app_id` IS NULL [0;33m[][0m 1.
>> Runtime for discovery module 'applications': 0.0330 seconds with -184
>> [0;36mSNMP[0m: [1/0.03s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module applications
Modules status:
OS
Device
OS
Device
#### Load disco module services
>> Runtime for discovery module 'services': 0.0000 seconds with 80
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module services
Modules status:
OS-
Device
OS-
Device
Module [ stp ] disabled on
Modules status:
OS
Device
OS
Device
#### Load disco module ntp
>> Runtime for discovery module 'ntp': 0.0000 seconds with 80
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module ntp
Modules status:
OS
Device
OS
Device
#### Load disco module loadbalancers
>> Runtime for discovery module 'loadbalancers': 0.0000 seconds with 80
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module loadbalancers
Modules status:
OS
Device
OS
Device
Module [ mef ] disabled
Modules status:
OS
Device
OS
Device
#### Load disco module wireless
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"ap-count"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"clients"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"quality"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"capacity"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"utilization"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"rate"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"ccq"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"snr"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"sinr"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"rsrp"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"rsrq"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"ssr"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"mse"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"xpi"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"rssi"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"power"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"noise-floor"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"errors"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"error-ratio"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"error-rate"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"frequency"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"distance"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"cell"][0m 1.
SQL[[1;33mSELECT * FROM `wireless_sensors` WHERE `device_id`=? AND `sensor_class`=? [0;33m[12,"channel"][0m 1.
>> Runtime for discovery module 'wireless': 0.0520 seconds with 13288
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [24/0.28s] [0;32mRRD[0m: [0/0.
#### Unload disco module wireless
Modules status:
OS
Device
OS
Device
#### Load disco module fdb-table
SQL[[1;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = ? [0;33m[12][0m 0.
SQL[[1;33mSELECT * FROM `ports_fdb` WHERE `device_id` = ? [0;33m[12][0m 0.
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'Q-BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
dot1qTpFdbPort = No Such Object available on this agent at this
SNMP[[0;36m'/usr/bin/snmpbulkwalk' '-v2c' '-c' 'COMMUNITY' '-OQUsetX' '-m' 'BRIDGE-MIB' '-M' '/opt/librenms/mibs' 'udp:HOSTNAME:161'
dot1dTpFdbPort = No Such Object available on this agent at this
>> Runtime for discovery module 'fdb-table': 0.1120 seconds with 160
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [2/0.02s] [0;32mRRD[0m: [0/0.
#### Unload disco module fdb-table
Modules status:
OS
Device
OS
Device
#### Load disco module mpls
>> Runtime for discovery module 'mpls': 0.0020 seconds with 94696
>> [0;36mSNMP[0m: [0/0.00s] [1;33mMySQL[0m: [0/0.00s] [0;32mRRD[0m: [0/0.
#### Unload disco module mpls
SQL[[1;33mUPDATE `devices` set `last_discovered`=NOW(),`last_discovered_timetaken`=? WHERE `device_id` = ? [0;33m[8.583,12][0m 4.
Discovered in 8.583
.
./discovery.php 192.168.100.1 2022-11-07 07:20:45 - 1 devices discovered in 9.204
[0;36mSNMP[0m [106/6.52s]: Snmpget[60/4.59s] Snmpwalk[46/1.
[1;33mSQL[0m [98/1.70s]: Select[92/1.58s] Delete[4/0.
[1/0.03s] Update[1/0.
[0;32mRRD[0m [0/0.