From tslytsly, 6 Years ago, written in Plain Text.
This paste is a reply to Untitled from librenms - go back
Embed
Viewing differences between Untitled and Powerwalker UPS disco
LibreNMS Discovery
===================================
Version info:
Commit SHA: 701fbbc29b7a25e215032a6435fac72c06094976
Commit Date: 1499057076
DB Schema: 198
PHP: 7.0.18-0ubuntu0.16.04.1
MySQL: 10.0.29-MariaDB-0ubuntu0.16.04.1
RRDTool: 1.5.5
SNMP: NET-SNMP 5.7.3
==================================DEBUG!
SQL[[0;33mSHOW TABLES FROM librenms[0m] 
DB Schema update started....
SQL[[0;33mSELECT version FROM `dbSchema` ORDER BY version DESC LIMIT 1[0m] 
DB Schema already up to date.
SQL[[0;33mSELECT * FROM `devices` WHERE status = 1 AND disabled = 0 AND `hostname` LIKE 'ups' ORDER BY device_id DESC[0m] 
SQL[[0;33mSELECT * FROM devices_attribs WHERE `device_id` = '44'[0m] 
ups 44 powerwalker SQL[[0;33mINSERT INTO `device_perf` (`xmt`,`rcv`,`loss`,`min`,`max`,`avg`,`device_id`,`timestamp`)  VALUES ('3','3','0','0.73','1.09','0.93','44',NOW())[0m] 
SNMP Check response code: 0

Modules status: Global+ OS  Device  
#### Load disco module os ####
SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovq -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysDescr.0[0m]
Network Management Card for UPS

SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqn -M /opt/librenms/mibs udp:HOSTNAME:161 SNMPv2-MIB::sysObjectID.0[0m]
.*.4.1.935.10.1

| Network Management Card for UPS | .1.3.6.1.4.1.935.10.1 | 

>> Runtime for discovery module 'os': 0.1270 seconds with 848 bytes
#### Unload disco module os ####

Modules status: Global+ OS  Device  
#### Load disco module ports ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifDescr[0m]
ifDescr.1 = eth0
ifDescr.2 = LOOPBACK

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifName[0m]
ifName = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifAlias[0m]
ifAlias = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ifType[0m]
ifType.1 = softwareLoopback
ifType.2 = ethernetCsmacd

Array
(
    [1] => Array
        (
            [ifDescr] => eth0
            [ifType] => softwareLoopback
        )

    [2] => Array
        (
            [ifDescr] => LOOPBACK
            [ifType] => ethernetCsmacd
        )

)
SQL[[0;33mSELECT `name` FROM `port_association_mode` WHERE pom_id = '1'[0m] 
SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' ORDER BY port_id[0m] 
..

>> Runtime for discovery module 'ports': 0.3390 seconds with 2008 bytes
#### Unload disco module ports ####

Modules status: Global+ OS  Device  
#### Load disco module ports-stack ####
SQL[[0;33mSELECT * FROM `ports_stack` WHERE `device_id` = '44'[0m] 
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -M /opt/librenms/mibs udp:HOSTNAME:161 ifStackStatus[0m]



>> Runtime for discovery module 'ports-stack': 0.0100 seconds with 640 bytes
#### Unload disco module ports-stack ####

Modules status: Global+ OS  Device  
#### Load disco module entity-physical ####

Caching OIDs: entPhysicalEntrySNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-MIB:CISCO-ENTITY-VENDORTYPE-OID-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalEntry[0m]
entPhysicalEntry = No Such Object available on this agent at this OID

 entAliasMappingIdentifierSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m ENTITY-MIB:IF-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entAliasMappingIdentifier[0m]
entAliasMappingIdentifier = No Such Object available on this agent at this OID


SQL[[0;33mSELECT * FROM `entPhysical` WHERE `device_id` = '44'[0m] 

>> Runtime for discovery module 'entity-physical': 0.2300 seconds with 2928 bytes
#### Unload disco module entity-physical ####

Modules status: Global+ OS  Device  
#### Load disco module processors ####
 hrDevice: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDevice[0m]
hrDevice = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorLoad[0m]
hrProcessorLoad = No Such Object available on this agent at this OID

SQL[[0;33mSELECT COUNT(*) FROM `processors` WHERE `device_id` = '44' AND `processor_type` != 'ucd-old'[0m] 
SQL[[0;33mSELECT * FROM `processors` WHERE `device_id`  = '44'[0m] 


>> Runtime for discovery module 'processors': 0.1900 seconds with 36552 bytes
#### Unload disco module processors ####

Modules status: Global+ OS  Device  
#### Load disco module mempools ####
SQL[[0;33mSELECT COUNT(*) FROM `mempools` WHERE `device_id` = '44' AND `mempool_type` = 'cemp'[0m] 
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpLocal[0m]
hpLocalMem = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETSWITCH-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/hp udp:HOSTNAME:161 hpGlobal[0m]
hpGlobalMem = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m]
hrStorageEntry = No Such Object available on this agent at this OID

SQL[[0;33mSELECT * FROM `mempools` WHERE `device_id`  = '44'[0m] 


>> Runtime for discovery module 'mempools': 0.3080 seconds with 24672 bytes
#### Unload disco module mempools ####

Modules status: Global- OS  Device  Module [ cisco-vrf-lite ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module cisco-mac-accounting ####

>> Runtime for discovery module 'cisco-mac-accounting': 0.0000 seconds with 1056 bytes
#### Unload disco module cisco-mac-accounting ####

Modules status: Global+ OS  Device  
#### Load disco module cisco-pw ####

>> Runtime for discovery module 'cisco-pw': 0.0000 seconds with 1416 bytes
#### Unload disco module cisco-pw ####

Modules status: Global- OS  Device  Module [ cisco-vrf ] disabled globally.

Modules status: Global- OS  Device  Module [ cisco-cef ] disabled globally.

Modules status: Global- OS  Device  Module [ cisco-sla ] disabled globally.

Modules status: Global- OS  Device  Module [ cisco-cbqos ] disabled globally.

Modules status: Global- OS  Device  Module [ cisco-otv ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module ipv4-addresses ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntIfIndex[0m]
ipAdEntIfIndex.* 1
ipAdEntIfIndex.* 2

SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.127.0.0.1[0m]
*

SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '44' AND `ifIndex` = '1'[0m] 
SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '1'[0m] 
SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] 
SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '127.0.0.1/32'[0m] 
sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '127.0.0.1/32'[0m] 
SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '783' [0m] 
SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '127.0.0.1' AND `ipv4_prefixlen` = '32' AND `port_id` = '783'[0m] 
.SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAdEntNetMask.172.16.100.30[0m]
*

SQL[[0;33mSELECT COUNT(*) FROM `ports` WHERE device_id = '44' AND `ifIndex` = '2'[0m] 
SQL[[0;33mSELECT `port_id` FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '2'[0m] 
SQL[[0;33mSELECT COUNT(*) FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.100.0/24'[0m] 
SQL[[0;33mUPDATE `ipv4_networks` set `context_name` ='' WHERE `ipv4_network` = '172.16.100.0/24'[0m] 
sSQL[[0;33mSELECT `ipv4_network_id` FROM `ipv4_networks` WHERE `ipv4_network` = '172.16.100.0/24'[0m] 
SQL[[0;33mSELECT COUNT(*) FROM `ipv4_addresses` WHERE `ipv4_address` = '172.16.100.30' AND `ipv4_prefixlen` = '24' AND `port_id` = '784' [0m] 
SQL[[0;33mUPDATE `ipv4_addresses` set `context_name` ='' WHERE `ipv4_address` = '172.16.100.30' AND `ipv4_prefixlen` = '24' AND `port_id` = '784'[0m] 
.SQL[[0;33mSELECT `ipv4_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv4_addresses` LEFT JOIN `ports` ON `ipv4_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '44' OR `ports`.`device_id` IS NULL[0m] 


>> Runtime for discovery module 'ipv4-addresses': 0.1460 seconds with 4680 bytes
#### Unload disco module ipv4-addresses ####

Modules status: Global+ OS  Device  
#### Load disco module ipv6-addresses ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipAddressIfIndex.ipv6[0m]
ipAddressIfIndex.ipv6 No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -Ln -Osq -OnU -m IPV6-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipv6AddrPfxLength[0m]
.*.*.8.1.2 No Such Object available on this agent at this OID

SQL[[0;33mSELECT `ipv6_addresses`.*, `ports`.`device_id`, `ports`.`ifIndex` FROM `ipv6_addresses` LEFT JOIN `ports` ON `ipv6_addresses`.`port_id` = `ports`.`port_id` WHERE `ports`.device_id = '44' OR `ports`.`device_id` IS NULL[0m] 


>> Runtime for discovery module 'ipv6-addresses': 0.1960 seconds with 6752 bytes
#### Unload disco module ipv6-addresses ####

Modules status: Global+ OS  Device  
#### Load disco module route ####

>> Runtime for discovery module 'route': 0.0000 seconds with 1448 bytes
#### Unload disco module route ####

Modules status: Global+ OS  Device  
#### Load disco module sensors ####
Pre-cache powerwalker: upsInputEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsInputEntry[0m]
upsInputFrequency.1 = 500
upsInputVoltage.1 = 242
upsInputCurrent.1 = -1
upsInputTruePower.1 = -1

upsOutputEntry SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsOutputEntry[0m]
upsOutputVoltage.1 = 230
upsOutputCurrent.1 = -1
upsOutputPower.1 = -1
upsOutputPercentLoad.1 = 18


Array
(
    [powerwalker] => Array
        (
            [upsInputFrequency] => Array
                (
                    [1] => 500
                )

            [upsInputVoltage] => Array
                (
                    [1] => 242
                )

            [upsInputCurrent] => Array
                (
                    [1] => -1
                )

            [upsInputTruePower] => Array
                (
                    [1] => -1
                )

            [upsOutputVoltage] => Array
                (
                    [1] => 230
                )

            [upsOutputCurrent] => Array
                (
                    [1] => -1
                )

            [upsOutputPower] => Array
                (
                    [1] => -1
                )

            [upsOutputPercentLoad] => Array
                (
                    [1] => 18
                )

        )

)
 ENTITY-SENSOR: Caching OIDs: entPhysicalDescrSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalDescr[0m]
entPhysicalDescr = No Such Object available on this agent at this OID

 entPhysicalNameSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m CISCO-ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhysicalName[0m]
entPhysicalName = No Such Object available on this agent at this OID

 entPhySensorTypeSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorType[0m]
entPhySensorType = No Such Object available on this agent at this OID

 entPhySensorScaleSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorScale[0m]
entPhySensorScale = No Such Object available on this agent at this OID

 entPhySensorPrecisionSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorPrecision[0m]
entPhySensorPrecision = No Such Object available on this agent at this OID

 entPhySensorValueSNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m ENTITY-SENSOR-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 entPhySensorValue[0m]
entPhySensorValue = No Such Object available on this agent at this OID


SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '44' AND `attrib_type` = 'ipmi_hostname' [0m] 
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] 
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] 
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] 
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'ipmi'[0m] 
Airflow: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='airflow' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Current: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryCurrent.0[0m]
-1 0.1 Amp DC

Discover sensor: .1.3.6.1.2.1.33.1.2.6.0, 1, powerwalker, Battery Current, snmp, 1, 1, , 101
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] 
.Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.4.1.0, 2, powerwalker, Input Voltage, snmp, 1, 1, , 101
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] 
.Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.3.1.0, 3, powerwalker, Output Voltage, snmp, 1, 1, , 101
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'current' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '3'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'current' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '3'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [1] => 1
            [2] => 1
            [3] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='current' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
1 -> powerwalker
2 -> powerwalker
3 -> powerwalker

Charge: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsEstimatedChargeRemaining.0[0m]
100 percent

Discover sensor: .1.3.6.1.2.1.33.1.2.4.0, 1, powerwalker, Battery charge remaining, snmp, 1, 1, , 100
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'charge' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'charge' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [1] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='charge' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
1 -> powerwalker

Dbm: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='dbm' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Fanspeed: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='fanspeed' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Frequency: PowerWalker Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.2.1, 2, powerwalker, Input Voltage, snmp, 1, 1, , 100
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'frequency' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'frequency' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [2] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='frequency' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
2 -> powerwalker

Humidity: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='humidity' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Load: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='load' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Power: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='power' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

Runtime: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsEstimatedMinutesRemaining.0[0m]
41 minutes

Discover sensor: .1.3.6.1.2.1.33.1.2.3.0, 1, powerwalker, Battery time remaining, snmp, 1, 1, , 41
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'runtime' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'runtime' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [1] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='runtime' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
1 -> powerwalker

Signal: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='signal' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 

State: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Ovqe -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryStatus.0[0m]
2

SQL[[0;33mSELECT `state_index_id` FROM state_indexes WHERE state_name = 'upsBatteryStatus' LIMIT 1[0m] 
SQL[[0;33mSELECT * FROM `state_translations` WHERE `state_index_id` = '920'[0m] 
Discover sensor: .1.3.6.1.2.1.33.1.2.1.0, 0, upsBatteryStatus, Battery Status, snmp, 1, 1, 0, 
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'state' AND `device_id` = '44' AND sensor_type = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '44' AND `sensor_type` = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] 
.SQL[[0;33mSELECT sensor_id FROM `sensors` WHERE `sensor_class` = 'state' AND `device_id` = '44' AND `sensor_type` = 'upsBatteryStatus' AND `sensor_index` = '0'[0m] 
SQL[[0;33mSELECT state_index_id FROM `state_indexes` WHERE `state_name` = 'upsBatteryStatus'[0m] 
SQL[[0;33mINSERT INTO `sensors_to_state_indexes` (`sensor_id`,`state_index_id`)  VALUES ('790','920')[0m] 
Array
(
    [upsBatteryStatus] => Array
        (
            [0] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='state' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
0 -> upsBatteryStatus

Temperature: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryTemperature.0[0m]
28 degrees Centigrade

Discover sensor: .1.3.6.1.2.1.33.1.2.7.0, 1, powerwalker, Ambient Temperature, snmp, 1, 1, , 28
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'temperature' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'temperature' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [1] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='temperature' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
1 -> powerwalker

Voltage: PowerWalker SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m UPS-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 upsBatteryVoltage.0[0m]
2054 0.1 Volt DC

Discover sensor: .1.3.6.1.2.1.33.1.2.5.0, 1, powerwalker, Battery Voltage, snmp, 1, 1, , 205401
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '1'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '1'[0m] 
.Discover sensor: .1.3.6.1.2.1.33.1.3.3.1.3.1, 2, powerwalker, Input Voltage, snmp, 1, 1, , 205401
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '2'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '2'[0m] 
.Discover sensor: .1.3.6.1.2.1.33.1.4.4.1.2.1, 3, powerwalker, Output Voltage, snmp, 1, 1, , 205401
SQL[[0;33mSELECT COUNT(sensor_id) FROM `sensors` WHERE `poller_type`= 'snmp' AND `sensor_class` = 'voltage' AND `device_id` = '44' AND sensor_type = 'powerwalker' AND `sensor_index` = '3'[0m] 
SQL[[0;33mSELECT * FROM `sensors` WHERE `sensor_class` = 'voltage' AND `device_id` = '44' AND `sensor_type` = 'powerwalker' AND `sensor_index` = '3'[0m] 
.Array
(
    [powerwalker] => Array
        (
            [1] => 1
            [2] => 1
            [3] => 1
        )

)
SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='voltage' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 
1 -> powerwalker
2 -> powerwalker
3 -> powerwalker

Snr: SQL[[0;33mSELECT * FROM sensors AS S, devices AS D WHERE S.sensor_class='snr' AND S.device_id = D.device_id AND D.device_id = '44' AND S.poller_type = 'snmp'[0m] 


>> Runtime for discovery module 'sensors': 0.9540 seconds with 11344 bytes
#### Unload disco module sensors ####

Modules status: Global+ OS  Device  
#### Load disco module storage ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m EQLVOLUME-MIB -M /opt/librenms/mibs:/opt/librenms/mibs/equallogic udp:HOSTNAME:161 EqliscsiVolumeEntry[0m]
eqliscsiVolumeEntry = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES:NetWare-Host-Ext-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 hrStorageEntry[0m]
hrStorageEntry = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m NETAPP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dfEntry[0m]
dfEntry = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-SNMP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dskTable[0m]
dskTable = No Such Object available on this agent at this OID

SQL[[0;33mSELECT `storage_descr` FROM `storage` WHERE `device_id`  = '44' AND `storage_type` != 'dsk'[0m] 
SQL[[0;33mSELECT * FROM `storage` WHERE `device_id`  = '44'[0m] 


>> Runtime for discovery module 'storage': 0.3630 seconds with 3232 bytes
#### Unload disco module storage ####

Modules status: Global+ OS  Device  
#### Load disco module hr-device ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrDeviceEntry[0m]
hrDeviceEntry = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m HOST-RESOURCES-MIB:HOST-RESOURCES-TYPES -M /opt/librenms/mibs udp:HOSTNAME:161 hrProcessorEntry[0m]
hrProcessorEntry = No Such Object available on this agent at this OID

Array
(
)
SQL[[0;33mSELECT * FROM `hrDevice` WHERE `device_id`  = '44'[0m] 


>> Runtime for discovery module 'hr-device': 0.1890 seconds with 792 bytes
#### Unload disco module hr-device ####

Modules status: Global+ OS  Device  
#### Load disco module discovery-protocols ####
 CISCO-CDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m CISCO-CDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 cdpCache[0m]
cdpCache = No Such Object available on this agent at this OID

Array
(
)
 LLDP-MIB: SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY  -OQUs -m LLDP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 lldpRemoteSystemsData[0m]
lldpRemoteSystemsData = No Such Object available on this agent at this OID

lldpRemoteSystemsData = No Such Object available on this agent at this OID || lldpRemoteSystemsData ||  ||  || 
Array
(
)
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
dot1dBasePortIfIndex = No Such Object available on this agent at this OID

Array
(
)
 OSPF Discovery: enabled
SQL[[0;33mSELECT DISTINCT(`ospfNbrIpAddr`),`device_id` FROM `ospf_nbrs` WHERE `device_id`='44'[0m] 
xSQL[[0;33mSELECT * FROM `links` AS L, `ports` AS I WHERE L.local_port_id = I.port_id AND I.device_id = '44'[0m] 


>> Runtime for discovery module 'discovery-protocols': 0.2720 seconds with 4504 bytes
#### Unload disco module discovery-protocols ####

Modules status: Global+ OS  Device  
#### Load disco module arp-table ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToPhysicalPhysAddress[0m]
ipNetToPhysicalPhysAddress.1 = 0
ipNetToPhysicalPhysAddress.2 = 0

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m IP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 ipNetToMediaPhysAddress[0m]
ipNetToMediaPhysAddress.*.22 = e4:8d:8c:17:b8:0
ipNetToMediaPhysAddress.*.85 = 0:15:5d:32:60:13

SQL[[0;33mSELECT M.* from ipv4_mac AS M, ports AS I WHERE M.port_id=I.port_id AND I.device_id='44' AND M.context_name=''[0m] 
SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '1'[0m] 
SQL[[0;33mSELECT * FROM `ports` WHERE `device_id` = '44' AND `ifIndex` = '2'[0m] 
SQL[[0;33mDELETE FROM `ipv4_mac` WHERE `port_id` = '784' AND `mac_address`='00155d65a909' AND `ipv4_address`='172.16.100.83' AND `context_name`=''[0m] 
SQL[[0;33mDELETE `ipv4_mac` FROM `ipv4_mac` LEFT JOIN `ports`
 ON `ipv4_mac`.`port_id` = `ports`.`port_id` WHERE `ports`.`port_id` IS NULL[0m] 


>> Runtime for discovery module 'arp-table': 0.1870 seconds with 32368 bytes
#### Unload disco module arp-table ####

Modules status: Global- OS  Device  Module [ discovery-arp ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module junose-atm-vp ####

>> Runtime for discovery module 'junose-atm-vp': 0.0000 seconds with 488 bytes
#### Unload disco module junose-atm-vp ####

Modules status: Global- OS  Device  Module [ bgp-peers ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module vlans ####
SQL[[0;33mSELECT * FROM `vlans` WHERE `device_id` = '44'[0m] 
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dBasePortIfIndex[0m]
dot1dBasePortIfIndex = No Such Object available on this agent at this OID

IEEE8021-Q-BRIDGE-MIB VLANs: SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m IEEE8021-Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qVlanVersionNumber.0[0m]
No Such Object available on this agent at this OID



>> Runtime for discovery module 'vlans': 0.1270 seconds with 4352 bytes
#### Unload disco module vlans ####

Modules status: Global- OS  Device  Module [ vmware-vminfo ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module libvirt-vminfo ####

>> Runtime for discovery module 'libvirt-vminfo': 0.0000 seconds with 2232 bytes
#### Unload disco module libvirt-vminfo ####

Modules status: Global+ OS  Device  
#### Load disco module toner ####

 Checking valid toner ... 
Array
(
)
SQL[[0;33mSELECT * FROM toner WHERE device_id = '44'[0m] 
Array
(
)


>> Runtime for discovery module 'toner': 0.0000 seconds with 1264 bytes
#### Unload disco module toner ####

Modules status: Global+ OS  Device  
#### Load disco module ucd-diskio ####
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUs -m UCD-DISKIO-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 diskIOEntry[0m]
diskIOEntry = No Such Object available on this agent at this OID

Array
(
)
SQL[[0;33mSELECT * FROM `ucd_diskio` where `device_id`  = '44'[0m] 


>> Runtime for discovery module 'ucd-diskio': 0.0780 seconds with 864 bytes
#### Unload disco module ucd-diskio ####

Modules status: Global- OS  Device  Module [ applications ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module services ####

>> Runtime for discovery module 'services': 0.0000 seconds with 328 bytes
#### Unload disco module services ####

Modules status: Global+ OS  Device  
#### Load disco module stp ####
SQL[[0;33mSELECT * FROM `stp` WHERE `device_id` = '44'[0m] 
SNMP[[0;36m/usr/bin/snmpget -v2c -c COMMUNITY -Oqv -m RSTP-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dStpProtocolSpecification.0[0m]
No Such Object available on this agent at this OID



>> Runtime for discovery module 'stp': 0.0290 seconds with 3648 bytes
#### Unload disco module stp ####

Modules status: Global+ OS  Device  
#### Load disco module ntp ####

>> Runtime for discovery module 'ntp': 9.3930 seconds with 144 bytes
#### Unload disco module ntp ####

Modules status: Global- OS  Device  Module [ loadbalancers ] disabled globally.

Modules status: Global- OS  Device  Module [ mef ] disabled globally.

Modules status: Global+ OS  Device  
#### Load disco module wireless ####
Attempting to initialize OS: powerwalker
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='ap-count'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='clients'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='quality'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='capacity'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='utilization'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='rate'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='ccq'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='snr'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='rssi'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='power'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='noise-floor'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='error-ratio'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='error-rate'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='frequency'[0m] 
SQL[[0;33mSELECT * FROM `wireless_sensors` WHERE `device_id`='44' AND `sensor_class`='distance'[0m] 

>> Runtime for discovery module 'wireless': 0.0100 seconds with 131256 bytes
#### Unload disco module wireless ####

Modules status: Global+ OS  Device  
#### Load disco module fdb-table ####
SQL[[0;33mSELECT `vlan_id`, `vlan_vlan` from `vlans` WHERE `device_id` = '44'[0m] 
SQL[[0;33mSELECT * FROM `ports_fdb` WHERE `device_id` = '44'[0m] 
SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m Q-BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1qTpFdbPort[0m]
dot1qTpFdbPort = No Such Object available on this agent at this OID

SNMP[[0;36m/usr/bin/snmpbulkwalk -v2c -c COMMUNITY -OQUsetX -m BRIDGE-MIB -M /opt/librenms/mibs udp:HOSTNAME:161 dot1dTpFdbPort[0m]
dot1dTpFdbPort = No Such Object available on this agent at this OID



>> Runtime for discovery module 'fdb-table': 0.1920 seconds with 2136 bytes
#### Unload disco module fdb-table ####

Modules status: Global+ OS  Device  
#### Load disco module charge ####

>> Runtime for discovery module 'charge': 5.1970 seconds with 96 bytes
#### Unload disco module charge ####

SQL[[0;33mSELECT attrib_value FROM devices_attribs WHERE `device_id` = '44' AND `attrib_type` = 'poll_mib' [0m] 
SQL[[0;33mUPDATE `devices` set `last_discovered` =NOW(),`last_discovered_timetaken` ='4.386' WHERE `device_id` = '44'[0m] 
Discovered in 4.386 seconds

SQL[[0;33mINSERT INTO `perf_times` (`type`,`doing`,`start`,`duration`,`devices`,`poller`)  VALUES ('discover','ups','1499074932.9853','4.411','1','librenms\n')[0m] 
./discovery.php ups 2017-07-03 10:42:17 - 1 devices discovered in 4.411 secs
SNMP: Get[13/0.34s] Walk [32/2.97s]
MySQL: Cell[27/0.01s] Row[19/0.01s] Rows[57/0.03s] Column[1/0.00s] Update[5/0.00s] Insert[3/0.00s] Delete[1/0.00s]